Вы находитесь на странице: 1из 17
Courses Home (https://sso.te https://www.engineeringexamples.net/ (Mttps://www.engineeringexamples.net/) reset purcha Designing A One Way Ribbed Concrete Joist Floor System Per ACI Code 318-11 {8 January 17,2007 Abdu seal Pe einorced concrete design emo sa design a. one rbbed concrete lst oor stem per ACI Code 318-11, Wevil focus ou atention on tension. “luted sectors one eco macho comlecrelsSMecfagn lect pha scan ‘The problem statement states, ‘uasign an interior re of a concrete joist aor system glven the following informasion: ‘oan of ria =20 simply supported ‘Uniform Dead Load (Excluding self weight) = 20 pst Uniform Live Load =90 psf Compressive Strength of Concrete, f¢=3 isl Yile Strength of Reinforcement, y= 60 ksi 240 —— | PGE: 20” 4" 20" 1. Slab design Assume Clear spacing between ribs = Zo” 430 Aci Code 8.13.3 ACI Code 8.13.6-1 Slab Thickness = 2” \v S Assume iv ofth tae he design thickress ofthe slab multiplied by the unit weignt of concrete. A LUDL The self weight equal to 150 bt ® Zz" «150 |b = 5 fF self wight J stab = (Foye ay” 28 CET. Since we willbe cesigning a1 wide stip ofthe Thisis based o The third sep tency of units in the flowing steps. slob, v's a good Asce 7 Wu - stab e L ZOOL + 1.6 LL = 1220+259+ 16040) = 178 pst 148 Wb /i2" - 148 Ib 7 (=) fe his wil serve asthe require strengt fer the slab, and our des'gn wil be based on he fourth step is to determine the maximum factored moment Ife conser ou trip fixed tothe ribs at both ends, the maximum moment will be equal to the providing at ast his level af flexural factored load divided by 12 times the clear spacing between ribs squared LAS wh V ve fa ae Slab assumed fix to rib Ma- svab = Wa-stae) b slab) L* = (118 be (=. y im a: 12 Musab = 45.833 |b-St = .94583% k- fe = 55 k-in OM Flexurak Tensile Strenglt = 57f'e =f, Me = PIVF%* z vu" Ms 2 p51Fu fe" Cc T= bee = G2(a = Bm 12 12 ech: 2 4" Zz zZ M= 8 (0.55) 5 FHooe = },391. 402 lb-m L = 1.341 kem> Mu-stab Shrinka ge Reinfor cement g Jj, - .oole lin") 2D = 0432 is Act Code 7.12.2-1 oo 18 Zz 2" tranverse try #3 bor @ and pore LLel he seventh step isto find the total thickness ofthe rip heignt pls sl he minimum thiceness of nonprestressed beams or ene-way slabs Fr th ‘than or equalte the span length divided by 20, To use this formula properly th thickness minus the slab thickness. Lead on rib Aci Code Table 15a Minima Depth = £ = Zoniefte 12" Zo Zo rizortalte vies equal to the factored load cortriauton from the slab tmes the centerto-center he tenth step isto rib width @ bottom - 4" Assume ACL Code 813-2 yp ‘aa [\ lo £ 3.5 (4%) + Top width - Yn 4 g/t» a - 9 2" 12 Average width = 47+ 63" = 4, 833” _ Loe 3 50 Jb Weight a rib = ( 4922") (= ai fe = 50.344 Ibs fe Wenge 24" (146 psf) * 1-2 (50.344 a) ft 12" 7 yse. 413 Ib fe . 2 Muerib 2 (Wa-rib EO = (4 56.413 8) (2054) ee 8 8 Mu-rib = Z2B20.65 |b -Ft Z2.82065 k-¥é i 273.8486 k-in ‘The welt step ste choose a reasonable bar type forthe rb reinforcement and compute the effective depth, ofthe rit and sb assembly. The eflactve depth is equa tothe total slab depth minus the cover minus the reinforcement bar elameterdkidea by 2. The cover is equal 0 0.75" and 's based on ACI Code 31811 Section 7.72 Desiqn oJ rib Total Depth - 12” Lb SF AS Assume 2 5 bar L ra ad: l2z"- 2° - (4°) (>) 10.9738” RK u ‘The thirteenth steps to find the moment stength of tre flanges, OM ofthe T-shaped nib bases on the assumption of tension controled sections. This caleubt is based on the assumpvion thatthe T-section s behaving ikea rectanguler section where the depth of the Whitney stress block,“ is fess than or ‘equal to the slab thickness. the moment strength of the flange is ker than or equal the maximum factored momento the rib, our assumption is ial, and the rib must be designed as a vali, the moment sirength ofthe ange is less tran tne maximum factored mement onthe rib, our assum ‘section =¢ , T-sectron behaves like assume a re chengii\ or Sectior Moment Strength Js Flange Mn (Slange) * i " - i PMng (Slang ¢ (0.85) fic bb ld e) = 4 C85) (4) C24") (2) (10.438" - =) - \454. 643 K-in > Mua-erib Rib acts as @ rect angular section b= 24, azt Mas pha = GAsty (4-4) = § Assy (d- At ) \.1$tcb a. we - bx +o Bi Ag - phd Ay tMe = O 17f'eb 4(bo* Agr — .4 (60) (10-438) Ag + 273-818 =O 4 (0 1.7 c4) Czy 14.85 3 Apt - 540.652 Ags 273.848 °° Ag = HAN wn? teenth step i to calculate the minimum srr sig the following formula 4 choice of bar yp a = Achy = MI Go) =. 34g"4 EHR 0.85 f'cb BICLY(ZH) use 2 * 5 bars Ag: 2 Ay = 2.3m) = 2 GZ in? wt As z ~GLZin® s S b2in ONT bod 4.833") (10.438) Pmin = 34s 3 200 = Aci Code fy Fy lo.5.\ = 3 y4o00 = 200 60000 60000 OK Max As Act Code 10.2.7.1 | 0.855% [ (be budt + 03758, bud | Max Ay = 44 436) = 0.85 (4) (ca -~4.633)(2> * (315 (B59) (4.823000 Go 3.127 in? As s Nwax “ ¢ =0.4 ‘The last step isto check the shear strergzh ofthe nib. The design shear strength othe slab, yj, per ACI Code 218-11 Secton 11.2.1. and 8.138 s equalto the strength reduction factor times 2 times 1.1 times lamads times the square root ofthe compressive strength ofthe concrete times te average rb width times the effective depth, The maximum shear force the slab needs tobe designes for, V's equalto te shear force ata distance equal o the eectve depth away from the slab support per ACI Cade 318-11 Section 11.131, the design shear strength is greater than or equalto the maximum shear fo ign is saistactory, the design shear strength is ess than the maximum shear force, the design is unsatisfactory. Depending upon project requirements, ‘there may be a need to incarporate stirrups even if the design shear strength is greater than the maximum shear force, Furthermore, iis also advisable 10 clude a transverse iv atthe midspan ofthe slab system which uns perpendicular tothe eirection ofthe man ibs but has the same reinforcement as main ‘ibs This will act a5 a flor steer and is recammendes ‘or systerns where the lve loa is greater than 60 psf, ane the span length is between 13 and 23, " feet. Shear in rib Act Code W-2.1.4 rT 48! Code 8.13.8 av. = pt) 2ATs bed Aci Code 8.6.1 TH AAYZ a.o)T4ooo (4.833) (10.93 8) Ve = 5516.56H Ibs = 456.413 |b ' ( WY C20 456.413 te /10.438° FL =, Zz (i) : 414g cit tbs OV. > Vu OK Mini mun Stier ups Since LL? io re? ao' iC span of rib 13 4+ L + 23 franverse rib @ mids paw add one bo direction of ribs perpendi cular with Same reinforcement as main ribs Andul Sia ‘Computing the Minimem Required Twe Woy Slab Thickness fr the interior and Corner Pats ofa Fla Plt Floor System Urehwycenginesrngexarples.netlcomputingshe-inimur>-requracswo-nay-lsbhieknes-fortnesnterior-andcomer-panal-ota-atplatesioor- stern) enforced Concrete Design of Twos Sab per ACI Code (tps/uwav.engineerngexamplesnet/computng-ninimurrequlred-wonnay-slab-thickness interorpanele-foorsysem) Designing a Consinuous One Way Reinforced Contra Sab per ACI Coxe 318-1 tps vn engneeringexampesmet/ designing continuouone-tay reintoreacconeretealab-peracheode-31811), ow ip ona seongeoles nso Cat he umn seeing te) Tees ony regres atte fe Theme by Tenet htp/tesaractheme zon) _fitos/teseractheme com)

Вам также может понравиться