Академический Документы
Профессиональный Документы
Культура Документы
20:01:EE:54:7E:99:10:0a
20:01:EE:54:7E:99:10:0b
fab-A Fab-B
HDCSQL008_HBA_P0 HDCSQL008_HBA_P1
or
HDCSQL008_HBA0_P0 HDCSQL008_HBA0_P1
HDCSQL008_HBA1_P0 HDCSQL008_HBA1_P1
Free Ports
HDCCLR360_SPA_02 HDCCLR360_SPB_02
HDCSQL008_HBA_P0_HDCCLR360_SPA_02_FABA
HDCSQL008_HBA_P1_HDCCLR360_SPB_02_FABB
HDCSQL008_HBA_P0 HDCSQL008_HBA_P1
HDCCLR360_SPA_02 HDCCLR360_SPB_02
MDS-9140-E(config-if)# exit
MDS-9140-E(config)# vsan database
MDS-9140-E(config-vsan-db)# vsan 100 int
interface interop
MDS-9140-E(config-vsan-db)# vsan 100 interface fc1/1
vsan 100 is not configured on the switch
MDS-9140-E(config-vsan-db)# show vsan usage\
^
% invalid command detected at '^' marker.
MDS-9140-E(config-vsan-db)# exit
MDS-9140-E(config)# exit
MDS-9140-E# show vsan usage
8 vsan configured
configured vsans:1-2,10,12,101,121,201,1212
vsans available for configuration:3-9,11,13-100,102-120,122-200,202-1211,1213-40
93
MDS-9140-E# conf t
Enter configuration commands, one per line. End with CNTL/Z.
MDS-9140-E(config)# vsan database
MDS-9140-E(config-vsan-db)# vsan 101 inter
interface interop
MDS-9140-E(config-vsan-db)# vsan 101 interface fc1/1
MDS-9140-E(config-vsan-db)# exit
MDS-9140-E(config)# show interface fc1/1
^
% invalid command detected at '^' marker.
MDS-9140-E(config)# exit
MDS-9140-E# show interface fc1/1
fc1/1 is down (Link failure or not-connected)
Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN)
Port WWN is 20:01:00:0d:ec:13:24:80
Admin port mode is auto, trunk mode is on
snmp link state traps are enabled
Port vsan is 101
Receive data field Size is 2112
Beacon is turned off
5 minutes input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
5 minutes output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
1 frames input, 144 bytes
0 discards, 0 errors
0 CRC, 0 unknown class
0 too long, 0 too short
1 frames output, 144 bytes
0 discards, 0 errors
0 input OLS, 0 LRR, 0 NOS, 0 loop inits
0 output OLS, 0 LRR, 0 NOS, 1 loop inits
MDS-9140-E# sh f
fc-redirect fcanalyzer fcid-allocation fdmi
fc-tunnel fcc fcns file
fc2 fcdomain fcroute fips
fc2d fcdroplatency fcs flogi
fcalias fcflow fctimer fspf
MDS-9140-E# sh flogi database
No flogi sessions found.
MDS-9140-E# conf t
Enter configuration commands, one per line. End with CNTL/Z.
MDS-9140-E(config)# device-alias database
MDS-9140-E(config-device-alias-db)# ?
Database configuration commands:
device-alias Device-alias configuration commands
do EXEC command
end Exit from configure mode
exit Exit from this submode
no Negate a command or set its defaults
MDS-9140-E(config-device-alias-db)# exit
MDS-9140-E(config)# ?
Configure commands:
aaa Configure aaa functions
arp [no] remove an entry from the ARP cache
banner Configure banner message
boot Configure boot variables
callhome Enter the callhome configuration mode
cdp CDP Configuration parameters
cfs CFS configuration commands
cimserver Modify cimserver configuration
cli CLI configuration commands
clock Configure time-of-day clock
cluster Configure Cluster
crypto Set crypto settings
device-alias Device-alias configuration commands
do EXEC command
dpvm Configure Dynamic Port Vsan Membership
end Exit from configure mode
exit Exit from configure mode
fabric-binding Fabric Binding configuration
fc-redirect FC-Redirect configuration commands
fc-tunnel Configure fc-tunnel
fcalias Fcalias configuration commands
fcanalyzer Configure cisco fabric analyzer
fcc Configure FC Congestion Control
fcdomain Enter the fcdomain configuration mode
fcdroplatency Configure switch or network latency
fcflow Configure fcflow
fcid-allocation Add/remove company id(or OUIs) from auto area list
fcinterop Interop commands
fcip Enable/Disable FCIP
fcns Name server configuration
fcroute Configure FC routes
fcrxbbcredit Enable extended rx b2b credit configuration
fcs Configure Fabric Config Server
fcsp Config commands for FC-SP
fctimer Configure fibre channel timers
fdmi Config commands for FDMI
ficon Configure ficon information
fips Enable/Disable FIPS mode
fspf Configure fspf
in-order-guarantee Set in-order delivery guarantee
interface Select an interface to configure
ip Configure IP features
ipv6 Configure IPv6 features
iscsi Enable/Disable iSCSI
ivr Config commands for IVR
kernel Kernel options
line Configure a terminal line
logging Modify message logging facilities
mcast Configure multicast
no Negate a command or set its defaults
npiv Nx port Id Virtualization (NPIV) feature enable
ntp NTP Configuration
port-monitor Configure port monitor
port-security Configure Port Security
port-track Configure Switch port track config
power Configure power supply
poweroff Poweroff a module in the switch
qos QoS Configuration commands
radius Configure RADIUS configuration
radius-server Configure RADIUS related parameters
rate-mode Configure rate mode oversubscription limit
rib Configure RIB parameters
rlir Config commands for RLIR
rmon Remote Monitoring
role Configure roles
rscn Config commands for RSCN
san-ext-tuner Enable/Disable San Extension Tuner tool
scheduler Config commands for scheduler
scsi-target Scsi-target configuration
sdv Config commands for SAN Device Virtualization
sme Enable/Disable Storage Media Encryption
snmp-server Configure snmp server
span Enter SPAN configuration mode
ssh Configure SSH parameters
switchname Configure system's network name
system System config command
tacacs+ Enable tacacs+
telnet Enable telnet
tlport Configure TL Port information
trunk Configure Switch wide trunk protocol
username Configure user information.
vsan Enter the vsan configuration mode
wwn Set secondary base MAC addr and range for additional WWN
s
zone Zone configuration commands
zone-attribute-group Zone attribute group commands
MDS-9140-E(config)# ^C
MDS-9140-E(config)# exit
MDS-9140-E# show device-alias database
device-alias name test1 pwwn 10:00:00:00:c9:6d:91:ea
device-alias name test2 pwwn 10:00:00:00:c9:6d:91:eb
device-alias name test3 pwwn 10:00:00:00:c9:6d:91:ec
device-alias name Etest1 pwwn 50:00:00:00:c9:6d:91:ec
device-alias name Etest2 pwwn 50:00:00:00:c9:6d:91:eb
device-alias name Etest3 pwwn 50:00:00:00:c9:6d:91:ea
device-alias name host-E pwwn 10:00:00:00:c9:41:ab:1c
device-alias name disk1-p1 pwwn 50:06:04:8c:4a:40:ba:11
device-alias name disk2-p1 pwwn 50:06:04:8c:4a:40:ba:1e
device-alias name host2-p1 pwwn 10:00:00:00:c9:6d:98:5e
device-alias name emulex_hba pwwn 10:00:00:00:c9:49:8a:2d
device-alias name symm_storage pwwn 50:06:04:84:3d:48:ac:d3
device-alias name storage-milan pwwn 50:06:04:84:3d:48:ac:cd