ASTRON GROUP Inspection Report

www.astrongroup.com

Client: Nasser S. Al-Hajri Corporation Report No: 40


Project: SA Onshore Maintain Potential Program ASA No.: 146
PO No.: 124-2531 Location: Site 1, Jubail
Visit Date: 20th,21st & 22nd Nov
IL No.: 107000127289
2017
Vendor: Arabian Pipe Coating Next Visit: 23rd Nov 2017
Sub vendor: N/A Client Ref: Sreekumar
Vendor Job Ref: 30001446 Client Contact: +966 515147500
DETAILS OF ITEMS INSPECTED
Item No Qty Description Traceability
(Tag No., Batch No.,
Serial No., Cast No.,
Heat No.)
1 51 Inspection of Various Sized Spools & Fittings that were Refer to IRN – 040 &
Internal FBE Coated Tally Sheet
Results of Inspection Order status

Compliance  Non-Compliance ☐ Complete ☐ Incomplete 

Inspection Summary:
Inspection visit was made at APCO Site-1 for witnessing internal FBE coating of Pipe spools and Fittings of various
sizes.
Carried out stage wise inspection of Pipe spools and fittings only in the day shift.
Total number of Pipe spools inspected were 48 no’s & fittings were 3 no’s, among which all were accepted and
IRN 40 was issued.

Attachments NCR ☐ Punch List ☐ Release Note  Certificate 


RECORD OF HOURS
Inspection / Report Hrs.: 10 Travelling Hrs.: 3 Distance Travelled: 200 Km
Inspection Engineer Inspection Engineer

Name Fahad Ahmad. Name Mujtaba Khudar

Date 25/11/2017 Date 27/11/2017

DAAKEN OILFIELD SERVICES & PRODUCTS CO. LTD.


Office No. 108, Aram Business Centre, Tariq Bin Ziyad Street, Rakkah, Al-Khobar, KSA
T: 013 894 4826 | E: astron-saudi@astrongroup.com
ASTRON Form No. L4-AST-046 Rev 2
Page 1 of 10
ASTRON GROUP Inspection Report
www.astrongroup.com

1. Personnel Met

S. No Name Designation Company


1 Fahad Ahmad Inspection Engineer Astron Certification on behalf of NSH Company
2 Ashraf QC Inspector Arabian Pipe Coating
3 Anbanuahan.N QC Inspector Arabian Pipe Coating

2. Reference Documents (Codes, Standards & SAMSS) / Approval status

Reference Document Approval Status/Name


09-SAMSS-091-Oct-2011 Shop Applied Internal Coating
SAES-H-002-Jun-2012 External & Internal coatings of pipes and pipe lines.
ITP-09 Rev. 01 Inspection & test plan

3. Inspection Performed

PO ORDE PRESENTED ACCEPTED QTY QTY


ITEM DESCRIPTION
ITEM RED THIS VISIT THIS VISIT REJECTED RELEASED

Pipe Spools 1 48 48 0 48
Fittings 1 3 3 0 3 Commented [NJ1]: Enter the Ordered quantity as per the
Client PO for each line item.

Inspection Activities Performed

ITP Clause Inspection Activity Description Result

1 Coating Material Receipt Accepted

3.0 Climatic Conditions Accepted

3.1 Compressed Air Supply Accepted

3.2 Abrasive Contamination Test Accepted

4.1 Abrasive Blast Visual Inspection Accepted

4.2 Surface Profile Accepted

4.3 Residual Surface Chlorides Accepted

4.5 Surface Dust Level Accepted

4.8 Elapse Time from Abrasive Blast to Primer Application/ Pre-heat Accepted

5.0 Primer Mixing Accepted

5.1 Phenolic Primer Viscosity Accepted

5.3 Phenolic Primer DFT Accepted

DAAKEN OILFIELD SERVICES & PRODUCTS CO. LTD.


Office No. 108, Aram Business Centre, Tariq Bin Ziyad Street, Rakkah, Al-Khobar, KSA
T: 013 894 4826 | E: astron-saudi@astrongroup.com
ASTRON Form No. L4-AST-046 Rev 2
Page 2 of 10
ASTRON GROUP Inspection Report
www.astrongroup.com

6.0 Pre-Heat Accepted

6.2 Post Cure Accepted

7.0 Visual Inspection Accepted

7.1 Adhesion Test Accepted

7.3 Dry Film Thickness Accepted

7.4 Holiday Detection Accepted

8.0 Repairs Accepted

8.1 Fitting Identification Markings Accepted

8.2 Spool/Fitting Storage Accepted

9.1 DCS Analysis Accepted

10.1 Micrometer Pyrometer Accepted

10.2 Dry Film Thickness Gauge Calibration Accepted

10.3 Holiday Detector Calibration Accepted

11.0 Documentation Accepted

Inspection Details

 Abrasive material test certificates along with FBE powder and primer certificates were reviewed
and found acceptable.
 Climate conditions were checked, and the surface temperature of the substrate was found to be
3C0 above the dew point temperature.
 Blotter test was performed to make sure that there is no sign of oil & moisture.
 Abrasive blast visual inspection was performed as per SSPC-SP 5 or NACE 1 or SA3 and was found
acceptable.
 Surface profile measurement were checked with the help of a profile gauge and the profile range
was within the acceptable range. i.e. 50 µm to 100µm.
 Surface dust level was checked and was found acceptable.
 Surface chloride residues level was checked and deemed acceptable.
 Mixing of the primer was monitored as per the data sheet prior to the application.
 Viscosity of the primer was also checked by the help of viscosity cup number 4 and was found to
be with in the manufacturer’s recommended range.
 Primer application was monitored. DFT was visually checked in such a way that the surface profile
peaks were faintly exposed.
 Pre-heat temperature was randomly checked and was as per manufacturers recommendations.
 Application of FBE powered was randomly checked.
 Final visual inspection of the spools was done, and the surface was found to be uniform in color
and gloss.
 Adhesion X-cut was performed to check the cohesive strength of the applied FBE coating.
 Dry film thickness (DFT) of the final coating was checked and was found to be in the acceptable
range i.e. (15mils-25 mils).

DAAKEN OILFIELD SERVICES & PRODUCTS CO. LTD.


Office No. 108, Aram Business Centre, Tariq Bin Ziyad Street, Rakkah, Al-Khobar, KSA
T: 013 894 4826 | E: astron-saudi@astrongroup.com
ASTRON Form No. L4-AST-046 Rev 2
Page 3 of 10
ASTRON GROUP Inspection Report
www.astrongroup.com

 Holiday test was performed on the spools to ensure that the spools were free from holiday. The
voltage of the detector was 2.2KV.
 Repairs which were smaller in size (≤ 233 cm2) were marked and repaired as per manufacturers
repair material, moreover they were again holiday tested to ensure that there is no holiday
present.
 Stenciling on the spools was checked and was found to be acceptable.
 DSC Analysis documentation was reviewed and were found to be in the acceptable range of -2C0
to +3 C0.
 Bend test was witnessed, and the documents were reviewed.

4. Measuring & Testing Equipment

Measuring Device Serial No. Calibration date Due date

0803840/HVD.001 07 Jan 2017 06 Jan 2018


Holiday Detector
SPY-018 27 July 2017 26 Jan 2018
Electronic DFT Gauge PJ10950/DFT.058 14 May 2017 13 May 2018
LJ03767/DFT .045 0 07 Jan 2017 06 Jan 2018
Dew point Meter 769382/DPM.035 20 June 2017 19 June 2018
Profile Gauge KBB661/SP.42 28 Mar 2017 27 Mar 2018
7335/SPG.002 28 Mar 2017 27 Mar 2018
Pyrometer PD3114/DGT.046 19 June 2017 18 June 2018
PD1775/DGT.36 28 Mar 2017 27 Mar 2018

5. Results and conclusions

 Internal FBE coating of Pipe spools and fittings was done. Results found satisfactory and
accepted.
 IRN- 040 for 61 spools & 25 fittings was issued, for further details please refer to the IRN & Tally
sheet.

6. HSE FEEDBACK ON VENDOR/ Any other point

No unsafe condition or unsafe act was found

7. Attachments

Lab Reports
QC Reports
IRN

DAAKEN OILFIELD SERVICES & PRODUCTS CO. LTD.


Office No. 108, Aram Business Centre, Tariq Bin Ziyad Street, Rakkah, Al-Khobar, KSA
T: 013 894 4826 | E: astron-saudi@astrongroup.com
ASTRON Form No. L4-AST-046 Rev 2
Page 4 of 10
ASTRON GROUP Inspection Report
www.astrongroup.com

8. Photographs

Weather condition check Blotter check

Surface Profile Surface profile measurement

DAAKEN OILFIELD SERVICES & PRODUCTS CO. LTD.


Office No. 108, Aram Business Centre, Tariq Bin Ziyad Street, Rakkah, Al-Khobar, KSA
T: 013 894 4826 | E: astron-saudi@astrongroup.com
ASTRON Form No. L4-AST-046 Rev 2
Page 5 of 10
ASTRON GROUP Inspection Report
www.astrongroup.com

Dust tape Dust analysis

Insertion of water in the patch Chloride analysis

DAAKEN OILFIELD SERVICES & PRODUCTS CO. LTD.


Office No. 108, Aram Business Centre, Tariq Bin Ziyad Street, Rakkah, Al-Khobar, KSA
T: 013 894 4826 | E: astron-saudi@astrongroup.com
ASTRON Form No. L4-AST-046 Rev 2
Page 6 of 10
ASTRON GROUP Inspection Report
www.astrongroup.com

VISCOSITY CHECK PRIMER APPLICATION

APPLICATION OF FBE POWDER APPLICATION OF FBE POWDER

DAAKEN OILFIELD SERVICES & PRODUCTS CO. LTD.


Office No. 108, Aram Business Centre, Tariq Bin Ziyad Street, Rakkah, Al-Khobar, KSA
T: 013 894 4826 | E: astron-saudi@astrongroup.com
ASTRON Form No. L4-AST-046 Rev 2
Page 7 of 10
ASTRON GROUP Inspection Report
www.astrongroup.com

DFT MEASUREMENT DFT MEASURMENT

X-CUT ADHESION TEST DSC SAMPLING

HOLIDAY OF THE SPOOL HOLIDAY DETECTION

DAAKEN OILFIELD SERVICES & PRODUCTS CO. LTD.


Office No. 108, Aram Business Centre, Tariq Bin Ziyad Street, Rakkah, Al-Khobar, KSA
T: 013 894 4826 | E: astron-saudi@astrongroup.com
ASTRON Form No. L4-AST-046 Rev 2
Page 8 of 10
ASTRON GROUP Inspection Report
www.astrongroup.com

PROFILE GAUGE CALIBERATION DEW POINT METER CALIBERATION

GMA GARNET 30/60 FBE POWDER

DAAKEN OILFIELD SERVICES & PRODUCTS CO. LTD.


Office No. 108, Aram Business Centre, Tariq Bin Ziyad Street, Rakkah, Al-Khobar, KSA
T: 013 894 4826 | E: astron-saudi@astrongroup.com
ASTRON Form No. L4-AST-046 Rev 2
Page 9 of 10
ASTRON GROUP Inspection Report
www.astrongroup.com

BEND TEST BENDED BARS

STROAGE STENCILLING

- End of Report -

DAAKEN OILFIELD SERVICES & PRODUCTS CO. LTD.


Office No. 108, Aram Business Centre, Tariq Bin Ziyad Street, Rakkah, Al-Khobar, KSA
T: 013 894 4826 | E: astron-saudi@astrongroup.com
ASTRON Form No. L4-AST-046 Rev 2