COMPLIANT FOR THE COMPLETE VENTILATION SOLUTION
2016
NUAI R E’S Nuaire is a world leader in the development and manufacture
PEDIG RE E of ventilation products and solutions. With roots stretching
back to the 1930s and a tradition of excellence in ventilation
since 1963, the Nuaire name has been at the forefront of the
industry for more than 40 years.
Nuaire is renowned worldwide for its expertise, commitment to innovation and the outstanding quality
NUAIRE’S MISSION of its products and customer service. People are at the heart of Nuaire, and the company has over 450
TO DELIVER EXCELLENCE IN EVERYTHING highly committed staff dedicated to customer satisfaction. These include leading experts who are
WE DO AND TO ALWAYS EXCEED constantly setting new standards for the industry by developing new, innovative products in the
CUSTOMER EXPECTATIONS. company’s research and development department – the largest and most advanced in the UK.
Nuaire was the first fan manufacturer in the world to achieve the quality standard ISO 9001, and
its commitment to quality remains embedded in all aspects of its operations.
With its roots in fans and mechanical ventilation products, Nuaire has progressively expanded its range
and extended its capabilities to encompass all technologies and levels of ventilation solutions. Nuaire
are the only company able to deliver the total ventilation solution for the built environment.
nuaire.co.uk 3
AIRE-VOLVE TWIN FANS
FEATURES & BENEFITS - ENSURES BEST PRACTICE DESIGN
ErP
COMPLIANT
2016
ACHIEVES 2010 BUILDING REGS LOWER NOISE UNIQUE INTELLIGENT DESIGN PRACTICE
LATEST EC MOTOR TECHNOLOGY DOUBLE WALLED PANEL WITH 35MM INNOVATIVE NEW FAN DESIGN
Guarantees longer life and lower SFPs. ACOUSTIC LINING In-line fan assembly provides optimum
Ensures lowest breakout. performance in a minimum space.
BUILT IN ECOSMART CONTROLS
Note: External units ‘X’ and ‘R’ are not fully
Energy efficient demand control 12 HOUR AUTO CHANGEOVER
acoustic lined as standard.
ventilation solution. Guarantees ventilation 24/7 in event of
MANUFACTURED FROM CORROSION fan/motor failure and extends life of fan.
CONSTANT PRESSURE OPTION
RESISTANT ALUZINC
Improves the energy performance of the overall ECOSMART PRE-PROGRAMMED
Longer life expectancy than other materials.
building and guarantees lower energy costs for SOFT START FUNCTION
end users. FULLY ENCLOSED FAN SPIGOT Helps prevent electrical overloading and
Fan and matching silencer system reduces breakout minimises mechanical wear.
MEETS CURRENT LEGISLATION AND
and guarantees a superior acoustic solution.
BUILDING REGULATIONS ALL UNITS ARE DESIGNED & MANUFACTURED
Lower energy consumption and better CLASS L2 LEAKAGE WITH PROCEDURES AS DEFINED IN
SBEM score. Units are tested to meet Class L2 leakage. BS EN ISO 9001 2000
(BS EN 1886 : 2007). Quality and reliability guaranteed.
MATCHED SILENCERS FULLY RETAINED BOTTOM ACCESS PANEL ‘R’ MODULE CAN BE ORDERED SEPARATELY
(EXTERNAL SILENCERS HAVE PITCHED ROOF) (INTERNAL RANGE ONLY) AND MOUNTED IN ANY ORIENTATION*
SMALLEST CASE SIZE BY DUTY SAVES TIMES AND MONEY ON SITE MAKES LIFE EASIER
UNIQUE PATENTED INLINE FAN DESIGN UNIQUE PATENTED DAMPER ARRANGEMENT WIDE DIRECT DUTY RANGE
Lower profile and reduced width. Fans to be installed horizontally, vertically, at any Available up to 1.9m3/s.
angle or mounted vertically downward if required.
RETAINED ACCESS PANEL ALUZINC FINISH
Lowers and slides under matched silencers EASY FIT MATCHING SILENCERS WITH QUICK Has 5 times longer life than galvanised steel and
where applicable. (Internal units only). FIT CLAMP BRACKETS provides higher wear resistance.
Can be easily incorporated into existing drop rod
MOST COMPACT ‘SIZE FOR DUTY’ CASE ECOSMART ENERGY EFFICIENCY CONTROL
supporting systems.
AVAILABLE ON THE MARKET Up to 80% controllability allowing the duty to be
Ideal for applications with restricted ceiling FULL LENGTH ACCESS PANEL WITH SAFETY adjusted if ductwork installation changes during
voids and bottom access is required. RETAINING FEATURES construction on site.
Easy access to motor and blower assemblies ensures
RE-MOUNTABLE CONTROL BOX PLUG IN ECOSMART CONTROL
quick installation, commissioning and maintenance.
Control can be mounted on either side of unit or to Integrated BMS interface as standard.
(Internal units only).
save space mounted remotely. (Internal units only).
FULL ACCESSORY RANGE
REMOVABLE UNIT END PANEL
UNIQUE TOP ACCESS PANEL Includes optional end panel with rectangular or
Can be attached to matched silencer prior to
External units have hinged roof for quick and circular spigot, remote cable for mounting of
connection to ducting system.
easy access. control box, matched silencers and dampers.
*To mount vertically refer to AVT-VK kit installation and EXTERNAL ROOF MODEL
5 YEAR WARRANTY
maintenance document. Inline (X) and grille outlet options (R).
Aire-Volve blowers are compliant to EC/327/2011. Peace of mind.
nuaire.co.uk 5
ENERGY SAVING ECOSMART CONTROLS
THE MOST FLEXIBLE ENERGY SAVING VENTILATION CONTROL SYSTEM
ON THE MARKET WITH FULL BMS INTERFACE
BE N E FITS
BMS
0-10V dc signal to activate the system and modulate
fan speed. Select/Deselect H&C. Note: this will over-
ride any other devices (eg. ES-UCF) fitted (except in
Constant Pressure fans).
ES-HTCSIG
Signal conditioning circuit for humidity, temperature
and CO2 sensors.
nuaire.co.uk 7
AIRE-VOLVE TWIN FANS
TECHNICAL INFORMATION
PERFORMANCE - AIRE-VOLVE INTERNAL TWIN FANS Casing
800
ISO 5801 2007
AMCA 300
700 V
Type D
Air Density 1.2 kg/m3
600
9
Fan Static Pressure (Pa)
500
7
Code descriptions
AVT2 - R
| | | |
1 2 3 4
1. Aire-Volve range
2. Twin Fan
3. Case size 1-9
4. Grille outlet external unit
nuaire.co.uk 9
AIRE-VOLVE TWIN FANS
TECHNICAL INFORMATION
PERFORMANCE - AIRE-VOLVE EXTERNAL TWIN FANS Casing
Code descriptions
AVT2 - X
| | | |
1 2 3 4
1. Aire-Volve range
2. Twin Fan
3. Case size 1-9
4. Inline external unit
39mm 40mm
*Control box
D
B
nuaire.co.uk 11
AIRE-VOLVE SILENCER SYSTEMS
TECHNICAL INFORMATION
INTERNAL UNIT
(AVT3-SYSTEM 1)
ErP
COMPLIANT
2016
Code descriptions
AVTCP1 - SYS1 - X
| | | | | |
1 2 3 4 5 6
1. Aire-Volve range
2. Twin Fan
3. CP = Constant Pressure control if required
4. Case size 1-9
5. System 1 = Fan unit & 2 standard silencers
System 2 = Fan unit & 2 long silencers
System 3 = Fan unit, 1 long & 1 standard silencer
6. X = External system with inline unit
R = External system with grille outlet unit*
SYSTEM 2 SYSTEM 3
nuaire.co.uk 13
AIRE-VOLVE SILENCER SYSTEM 1
1000mm
B1 B
A
1000mm
Standard silencer
C1
Twin Fan
Standard silencer
AVT SYSTEM 1 - ELECTRICAL & SOUND - c/w SHORT ATTENUATORS ACOUSTIC PERFORMANCE (PROVISIONAL)
A
1500mm
Long silencer C
Twin Fan C1
Long silencer
AVT SYSTEM 2 - ELECTRICAL & SOUND - c/w LONG ATTENUATORS ACOUSTIC PERFORMANCE (PROVISIONAL)
nuaire.co.uk 15
AIRE-VOLVE SILENCER SYSTEM 3
B1 B 1500mm
A
1000mm
C
Long silencer
C1
Twin Fan
Standard silencer
AVT SYSTEM 1 - ELECTRICAL & SOUND - c/w LONG ATTENUATOR ON ROOM SIDE / SHORT ATTENUATOR
ON ATMOSPHERE SIDE ACOUSTIC PERFORMANCE (PROVISIONAL)
nuaire.co.uk 17
AIRE-VOLVE CONSTANT PRESSURE TWIN FANS
BENEFITS
PRECISE VENTILATION UNIQUE DIRECT ACTING LESS POWER CONSUMPTION
The only multi-room ventilation system to MULTI-POSITION DAMPER NRG GRILLE System works at reduced duty therefore
provide local ‘on demand’ control. Ensures operation only when room occupied with consumes less power and is very quiet.
integrated PIR.
GUARANTEED VENTILATION WARRANTY
‘Hall effect’ airflow sensor provides 12 hour PRE-WIRED Ecosmart Constant Pressure has a
automatic changer in the event of fan/motor All components assembled, wired and tested at 5 year warranty.
failure, guaranteeing ventilation 24/7. the Nuaire manufacturing facility.
- Simply plug and go. No wiring required between Note: These units have the pressure sensor
QUIET OPERATION fan and dampers. configured for extract application. For sup-
Does not generate noise by throttling back on ply applications please contact Nuaire.
balancing dampers required in conventional MATCHED SILENCER OPTIONS Note: External fans and silencers have
systems. Double walled Aluzinc construction and 35mm infill pitched roofs.
acoustic lining providing the best acoustic solution. Note: For further details on Constant Pressure
TRUE DEMAND VENTILATION Note: External units are not fully acoustic lined as single fan options, please contact Nuaire.
Only the areas requiring ventilation receive standard.
ventilation.
DUCT MOUNTED CVD DAMPER
SAVES ENERGY For unobtrusive flexibility.
Up to 70% saving over conventionally controlled
central systems. INTERNAL OR EXTERNAL
- Not needlessly extracting conditioned air Twin fan options are available in internal or
- Fan speed/motor power dictated by demand external up to 1.9m3/s. For larger duties
requirement. contact Nuaire.
nuaire.co.uk 19
TWIN FANS CONSTANT PRESSURE
TECHNICAL INFORMATION
PERFORMANCE - CVD DAMPER Nominal Design Maximum Pressure
Code Pressure Drop Across Damper*
A nominal pressure drop must be allowed in order *Recommended maximum operating pressure to
CVD100 60Pa 120Pa
to ensure adequate airflow through the damper. ensure the damper would work within calibration
CVD125 70Pa 140Pa
To ensure the airflow pattern through the damper limits. Keep the duct velocity as low as possible to CVD150 80Pa 160Pa
produces consistent readings; the pressure drop ensure the system produces the lowest energy CVD200 90Pa** 200Pa
across the damper should not exceed the recom- usage, preferably below 5m/s.
mended value. Recommended values are listed in
the table below and shown in the performance **Allow 90Pa for duties below 100l/s and 150Pa
envelope of each damper. for duties between 100l/s and 125l/s.
nuaire.co.uk 21
AIRE-VOLVE CONSTANT PRESSURE Casing
TECHNICAL INFORMATION
PERFORMANCE - AIRE-VOLVE INTERNAL TWIN FANS
800
ISO 5801 2007
AMCA 300
700 V
Type D
Air Density 1.2 kg/m3
600 AVT Internal In-line Twin Fans.
NOTE: External range has pitched roof.
9
Fan Static Pressure (Pa)
400 AVTCP1
6
8
| | | |
300 5
1 2 3 4
3 4
200 1. Aire-Volve range
2 2. Twin Fan
4L 3. Constant pressure control options
100 4. Case size 1-9
1
39mm 40mm
*Control box
D
B
nuaire.co.uk 23
WIRING - AIRE-VOLVE TWIN FANS (INTERNAL & EXTERNAL)
Wiring for single phase units sizes 1-8.
All inter-connections between circuit boards,
blowers and sensors are made at the factory. This
diagram only shows the essential field wiring
points for clarity. *Remove link wire if switched
live signal, an enabler or BMS signal is connected.
Please refer to our commissioning guide 671565 for more info on Constant Pressure Systems.
*Note that the control panel is common to all the Ecosmart products and will have indicators for
functions that are not available in this particular fan. However these indicators will not be illuminated.
nuaire.co.uk 25
AIRE-VOLVE TWIN FANS (INLINE INTERNAL)
CONSULTANTS SPECIFICATION
VENTILATION SYSTEM DESCRIPTION SYSTEM OPERATION INSTALLATION
The main extract twin fan shall be as indicated on The extract fan shall automatically vary its speed By the appointed contractor.
the drawings and in accordance with the relevant as it receives signals from one of the intercon-
fan schedule. The stale air shall be extracted from nected sensors. When the signal is received the fan The Aire-Volve twin fan can be mounted in any
the space using an energy efficient demand shall either increase speed gradually until the orientation (internal units only). To mount
ventilation principle; the system shall have its required level is achieved or it will work on a trickle vertically, specifically designed brackets are
volume flow rate of air varied by a range of low and boost principle. This will then move the fan available from Nuaire. There is also an option to
voltage sensors and enablers. duty point from trickle/background ventilation rate mount the unit vertically downwards.
to the required boost ventilation rate.
FAN DESCRIPTION Mechanical installation requires mounting of
The unit shall be double skinned with 35mm infill Both the trickle and boost rates are infinitely the extract unit in the designated position and
panels and shall be manufactured from heavy variable, easy to adjust and remove the need of a connection to the associated duct work.
gauge, corrosion resistant Aluzinc steel, internally main balancing damper in accordance with Part L.
lined with acoustic material. Fully detachable A retained, full length sliding access panel
panels for maintenance/service. FAN CONTROL DESCRIPTION (internal units only) allows for quick and easy
The acoustically lined low noise twin fan shall be installation and maintenance. External units have
Note: External units do not have 35mm acoustic controlled by an integrated Ecosmart control a flush top or bottom access panel.
infil as standard. If infil is required contact Nuaire. panel mounted adjacent to the fan unit.
The Ecosmart control enables the fan’s speed to Electrical installation requires the provision and
The fan should be with an ‘inline assembly’, be varied automatically as conditions in the connection of single or three phase electrical
positioned in series for optimum performance. ventilated space change by linking low voltage supply at the fan.
sensors or as the low voltage user control is
Run and standby fan assemblies to incorporate adjusted. It also enables multiple fans to be The user control (ES-LCD) can be re-positioned
fan impeller and EC motors selected to provide directly interlinked. (internal units only) to the opposite side of the
the most energy efficient solution conforming to unit or remotely mounted using the AVT-CK
part L regulations. Units shall be direct drive with The fans shall have the following energy saving (Control Kit).
high efficiency motors as standard. EN60034-30 and operational functions integrally installed
motors fitted with ‘hall effect’ air flow failure within it, all components will be pre-wired and The user control and low voltage sensor are
monitoring, units suitable for operation in fitted by the manufacturer: supplied complete with a 10m length of low
ambient temperatures of 40ºC. • Auto change-over on fan failure voltage, pre-plugged cable.
• Auto duty share every 12 hours of run time
The Fan unit shall have a 5 year warranty. • Integral frequency inverter/speed controller COMMISSIONING
• Integral adjustable run-on timer By the appointed qualified commissioning
The unit and ancillaries shall be of the Aire-Volve • Maximum and minimum speed adjustment/set- engineer in accordance with CIBSE commissioning
type with Ecosmart controls as manufactured by ting (trickle and boost) Code A: Air Distribution Systems.
Nuaire Ltd. • Volt free run & failure/status indication
• 0-10V BMS interface for remote operation The systems should be commissioned in the way
INSTALLATION REQUIREMENTS • Low voltage interface with second fan or described in the aforementioned document and
The mechanical contractor shall ensure that all supply fan the minimum and maximum speed adjustment
necessary ancillaries are included eg. AV mounts, • Multiple low voltage sockets for interconnection with the Ecosmart control panel should be set to
flexible connections, attenuators, etc. of sensors or fans provide the required ventilation rates. These should
The contractor shall allow for all necessary • Background ventilation/trickle enable switch. be adjusted until the required air volume flow rate
ductwork transformations to and from the fan is achieved on the approved measuring device.
unit and any associated components in accordance Fan, Ecosmart controls and associated
with the manufacturer’s recommendations, DW sensors/controllers shall be manufactured by The manufacturer’s recommendations should be
144 and general good practice. Nuaire Ltd. observed at all times.
nuaire.co.uk 27
THE COMPLETE VENTILATION All buildings have their own unique requirements for ventilation. With the new government guidelines on
energy efficiency it is more difficult to maintain a comfortable, healthy environment whilst providing an
SOLUTION WHATEVER YOUR
energy efficient solution. Nuaire has over 40,000 product lines to select from whatever your requirements,
VENTILATION STRATEGY, WE
we have the solution from a small extract fan to large air handling units.
OFFER THE TOTAL VENTILATION
SOLUTION
AIR HANDLING UNITS
MULTI-ROOM VENTILATION
CONSTANT PRESSURE VARIABLE VOLUME CONSTANT PRESSURE VOLUME XBOXER PACKAGED HEAT RECOVERY
Twin fan and single fan - high performance extract Control damper - energy efficient volume damper Low depth, high performance range up to 5m3/s.
up to 2.65m3/s. for use with constant pressure twin fan.
ES-OPUSDC
IMPULSE HIGH TEMPERATURE EXTRACT AXUS SMOKE & AXT Energy efficient range of inline, sur-
Powerful impulse fan certified to EN12101-3 High temperature & ambient axial extract fans face and recessed fans up to 115l/s.
(300ºC for 2 hours). up to 85m3/s.
ECOSMART SQURBO
Energy efficient make up air supply
and extract units up to 0.5m3/s.
XTRACTOR
High efficiency centrifugal fan up
to 6.2m3/s.
TERMINATOR
Horizontal discharge roof
extract fan.
XS RANGE
Wall, window, ceiling and roof
extract fans (up to 530l/s).
SQUIF RANGE
Run and standby units ideal for
‘out of airstream’ applications
such as commercial kitchens.
Twin fan option.
nuaire.co.uk 29
AIRE-VOLVE
SINGLE EXTRACT FANS
ErP
COMPLIANT
2016
INDOOR RANGES
NEW - AIRE-VOLVE RANGE COMPACT - IDEAL FOR CEILING VOIDS MATCHED SILENCERS
nuaire.co.uk 31
FOR MORE INFORMATION
www.nuaire.co.uk
COMMERCIAL
www.nuaire.co.uk/commercial
RESIDENTIAL
www.nuaire.co.uk/residential
FAN SELECTOR
www.nuaire.co.uk/fanselector
Nuaire Limited
Western Industrial Estate | Caerphilly | CF83 1NA
t +44 (0)29 2085 8200 | f +44 (0)29 2085 8222 | e info@nuaire.co.uk
www.nuaire.co.uk
As part of our policy of continuous product development Nuaire reserves the right to alter specifications without prior notice.
Telephone calls may be recorded for quality and training purposes.