Best practice for good Performing Netkrom link Installation.

Due to persistence quality issue experience by the Netkrom link during previous
installation, below is best installation and planning practice for quality perfo
rming link
Installation survey should be done for minimum line of sight clearance and there
should not be any obstruction in between the link
After installation the RSSI should be increase at best as possible at both ends,
panning the antenna
IF cable length may permit the it preferable to use cable supply with Netkrom eq
uipment as it robust enough for outdoor condition
Minimum RSSI for link to be accepted and connected to customer should be 45
After installing Netkrom the link should properly commissioned and all performan
ce data that filled in to be develop form for reference to changes in the future
.
Data cable should be separated as much possible from signal cable
After installation it should be ensure that the CPE is Stable on the boom or any
construction it installed on.
The cable entry into the CPE must be ensured that it water seal and all unit of
the RJ 45 waterproof connector system is used.

NETKROM INSTALLATION AND COMMISSIONING REPORT

Basic system information


Near end identity or Name …………………………………… Associated
Far end identity or name ………………………………….. Associated

Mode of near end ……………………………….


Mode of far end ………………………………

IP address of Near end …………………………………….

IP address of Near end …………………………………

Physical data
Height of Near end CPE

Height of Far end CPE

Length of cable POE to CPE at near end


Length of cable POE to CPE at far end

Performance and quality data


RSSI at Near end

RSSI at Far end

Data rate at Near end (Mbps)

Data rate at Far end (Mbps)

Channel used for link

Channel frequency (MHZ)

Channel quality parameter

Channel Myquality Apcount


Neigbourquality Recommendation

Configuration data
Channel

Frequency
Antenna Control ……………………

Transmit power …………………………..

Outdoor …………………..

Distance

Slot time

Ack timeout

CTS timeout

Check list OK Not N/A Comment


CPE install properly and stable
IS Connection from CPE and POE ok
Data/ power cable to CPE install properly and free from strain and stress
Is Power cable and data seperated as best as posible
RSSI level ok
RSSI above 45
CPE align to maximum RSSI
Is data rate ok
Is there interference on use channel
RJ45 waterproof connector system use properly
Statistic pinging
Is Outdoor set to enable
Is Long distance time parameter set correctly
Data cable from POE to Switch or DACES ok
Prepare by………………………. Date………………..
Below is check list for Netkrom installation and preventive maintenance

Check OK Not OK N/A Comment


CPE stable on Tower
Data cable installed proper with no strain
RJ45 Waterproof connector use, and properly installed
Data Cable length not more than 50m
IS there any obstruction between the near and far end CPE
Is the power stable on site
Data and power cable separate as best as possible
POE power from UPS at Comium site
RSSI above 45
Is the POE installed power and is free from strain or stress
All connecting cables to POE connected properly and free from stress
Is there excess cable roll connecting the POE or CPE
cable from POE and Switch free from stress and there is proper contact
Statistics pinging result
IS there interference on the channel use
Is data TX rate ok
Distance and time parameter set properly at both ends
Outdoor Enable
TX power set to maximum
Antenna control set to auto