Вы находитесь на странице: 1из 1

Project

Job Number
Engineer
SAP2000

Eurocode 2-2004 COLUMN SECTION DESIGN Type: DC MEDIUM MRF Units: N, mm, C (Summary)

L=3000.000
Element : 70 B=300.000 D=300.000 dc=57.026
Section ID : SH 30x30 E=31000.000 fck,cyl=25.000 Lt.Wt. Fac.=1.000
Combo ID : UDCON10 fyk=500.000 fywk=500.000
Station Loc : 3000.000 RLLF=1.000 SOM: Nominal Curvature
Combo Eq. : Eq. 6.10

Gamma(Concrete): 1.500 AlphaCC=1.000 AlphaCT=1.000


Gamma(Steel) : 1.150 AlphaLCC=0.850 AlphaLCT=0.850

AXIAL FORCE & BIAXIAL MOMENT DESIGN FOR NEd, MEd2, MEd3
Rebar Design Design Design Minimum Minimum
Area NEd MEd2 MEd3 M2 M3
O/S #2 603694.305 203077937.0 21274357.33 12073886.10 12073886.10

AXIAL FORCE & BIAXIAL MOMENT FACTORS


M0Ed Madd Minimum Beta L
Moment Moment Ecc Factor Length
Major Bending(M3) 21274357.33 0.000 20.000 1.000 3000.000
Minor Bending(M2) 203077937.0 0.000 20.000 1.000 3000.000

SHEAR DESIGN FOR V2,V3


Rebar Shear Shear Shear Tan(Theta)
Asw/s VEd VRdc VRds Ratio
Major Shear(V2) 1.594 151533.797 97906.884 151533.797 0.000
Minor Shear(V3) 1.685 160179.320 97906.884 160179.320 0.000

AXIAL COMPRESSION RATIO


Conc.Capa CompRatio CompRatio Seismic CompCheck Ratio
A*fcd Ned/(A*fcd) Limit Load? Needed? OK?
1500000.000 0.402 0.650 Yes Yes Yes

JOINT SHEAR DESIGN


Joint Shear Shear Shear Shear Shear Joint
Ash VEd,Top Vjhd Vrd,Conc Ratio Area
Major Shear(V2) N/C N/C N/C N/C N/C N/C
Minor Shear(V3) N/C N/C N/C N/C N/C N/C

(1.3) BEAM/COLUMN CAPACITY RATIOS


Major Minor
Ratio Ratio
N/A N/A

O/S #2 Reinforcing required exceeds maximum allowed

Notes:
N/A: Not Applicable
N/C: Not Calculated
N/N: Not Needed

C:\Users\blacksn0w\Desktop\SAP - Kurs\Grupi SAP janar 2018\USHTRIMET\MODELI SHPIJA1.sdb 2/1/2018 6:41 PM

Вам также может понравиться