bizhub C353/C253/C203
3.4.16 Replacing the transfer belt unit
A. Periodically replacing parts/cycle
• Transfer belt unit: Every 150,000 prints
3 NOTE
• Before replacement operations of the transfer belt unit, make sure to turn OFF the
main power switch and the sub power switch.
B. Removal procedure
1. Open the right door.
2. Remove two screws [1] and release
[2]
the lock of the transfer belt unit [2].
Maintenance
[1]
A02EF2C029DA
[1]
A02EF2C030DA
[1]
A02EF2C031DA
41 3
3. Periodical check Field Service Ver. 4.0 Jun. 2008
bizhub C353/C253/C203
C. Reinstall procedure
1. Insert the transfer belt unit [1].
NOTE
• Insert the transfer belt unit with
care not to allow its docking gear to
be damaged by hitting it against the
rail or associated part.
• Do not touch the surface of the
image transfer belt unit.
• Cover the image transfer belt unit
with something such shade cloth to
protect its surface from dust or for-
[1] eign matter.
A02EF2C032DA
[1]
A02EF2C033DA
42
Field Service Ver. 4.0 Jun. 2008 3. Periodical check
bizhub C353/C253/C203
3.4.17 Cleaning of the image transfer entrance guide
A. Periodically cleaning parts/cycle
• Image transfer entrance guide: When the transfer belt unit is replaced
(every 150,000 print)
B. Procedure
1. Remove the transfer belt unit.
See P.41
2. Wipe the image transfer entrance
guide [1] clean of spilled toner and
dirt using a cleaning pad with water
or alcohol.
Maintenance
[1]
A02EF2C034DA
B. Procedure
1. Remove the transfer belt unit.
See P.41
2. Wipe the surface of the IDC/registra-
tion sensor/MK,YC [1] clean of
spilled toner and dirt using a cotton
bud.
[1]
A02EF2C035DA
43