ELECTRICAL
Earthing accessories
MODULE
ITEM NO DESCRIPTION 25
1.1.1 50MM DIA -STAINLESS STEEL EARTHING BOSS C/W M10 STAINLESS STEEL STUD, 70
WASHER AND NUTS.
40MM DIA -STAINLESS STEEL EARTHING BOSS C/W M10 STAINLESS STEEL STUD,
1.1.2 WASHER AND NUTS.
EARTH BAR
LIGHTING JUCTION BOX INCREASED SAFETY Ex'e' IIB T3,IP56 WITH 3 Nos.(M20)
CABLE ENTRIES, 3 Nos. (M20) Ex'de' IP66/67 BRASS NICKEL PLATED CABLE
1.2.1 GLAND (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR TERMINATION OF 2C X 2
2.5/6 Sq.mm ARMOURED CABLE (TYPE -RFOU /BFOU) AND 1No. (M20) Ex'd'
IP66/67 BRASS NICKEL PLATED BLOCKING PLUG.
LIGHTING JUCTION BOX INCREASED SAFETY Ex'e' IIB T3,IP56 WITH 4 Nos.(M20)
CABLE ENTRIES, 4 Nos. (M20) IP66/67 BRASS NICKEL PLATED CABLE GLAND
1.2.2 SUITABLE FOR TERMINATION OF 3C X 2.5/6 Sq.mm ARMOURED CABLE (TYPE -
LV1 / LV2) AND 1No. (M20) IP66/67 BRASS NICKEL PLATED BLOCKING PLUG.
FLUORESCENT LIGHT FIXTURE IP66/67, Ex 'e', T3, SUITABLE FOR ZONE-1 IIB
HAZARDOUS AREA, WITH 2x36W FLOURESCENT LAMP(TL-D 36W/840 OF
PHILIPS) 230V, 1PH(LINE TO LINE), 60Hz, INTEGRAL CONTROL GEAR BOX, 2xM20
CABLE ENTRY AND 2 Nos. (M20) EX'de' IP66/67 BRASS NICKEL PLATED DOUBLE
COMPRESSION CABLE GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (RFOU/BFOU ) AND 1 No. (M20)Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUG. (CHALMIT CAT. REFERENCE:
PRGE/236/BI) OR APPROVED EQUIVALENT
FLUORESCENT LIGHT FIXTURE IP66/67, Ex 'e', T3, SUITABLE FOR ZONE-1 IIB
HAZARDOUS AREA, WITH 2x18W FLOURESCENT LAMP(TL-D 18W/840 OF
PHILIPS) 230V, 1PH(LINE TO LINE), 60Hz, INTEGRAL CONTROL GEAR BOX, 2xM20
CABLE ENTRY AND 2 Nos. (M20) EX'de' IP66/67 BRASS NICKEL PLATED DOUBLE
COMPRESSION CABLE GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (RFOU/BFOU ) AND 1 No. (M20)Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUG. (CHALMIT CAT. REFERENCE:
PRGE/218/BI) OR APPROVED EQUIVALENT
2.3.2 POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (UPS POWER SUPPLY)
2.4.4 POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (UPS POWER SUPPLY)
FLOOD LIGHT FIXTURE WITH WIDE BEAM IP66/67, Ex 'de', T3, SUITABLE FOR
ZONE-1 IIB HAZARDOUS AREA, WITH 125W HIGH POWER LIGHT EMITTING
DIODES(LEDs) - 230V, 1PH(LINE TO LINE), 60Hz, INTEGRAL CONTROL GEAR
BOX,2xM20 CABLE ENTRY AND 2 Nos. (M20) EX'de' BRASS NICKEL PLATED
DOUBLE COMPRESSION CABLE GLANDS (MAKE :HAWKE 501/453/UNIV)
SUITABLE FOR ARMOURED/BRAIDED CABLE (RFOU/BFOU) AND 1 No.(M20)
Ex'd' IP66/67 BRASS NICKEL PLATED BLOCKING PLUG. (CHALMIT CAT.
REFERENCE: SOLD/12L/LE) OR APPROVED EQUIVALENT
ELECTRICAL JUNCTION BOX, SS316L, IP 66 Ex`d', T3, SUITABLE FOR ZONE-1 IIB
HAZARDOUS AREA, WITH EXTERNAL BRASS EARTHING STUD AND 1No.(M20)
CABLE ENTRY AND 1No.(M20) IP66/67 Ex'd' BRASS NICKEL PLATED DOUBLE
COMPRESSION CABLE GLANDS SUITABLE FOR 2C x 6sq.mm x LPF/EPR
INSULATED FIRE RESISTANT (MGT) AND ARMOURED CABLE FROM MODULE - 20
EMERGENCY LIGHTING DB AND 1No.(M20) CABLE ENTRY WITH Ex`d' IP66/67
6.1.1 2
BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLAND SUITABLE FOR 2C
X 4sq.mm HEAVY DUTY TYPE COPPER CONDUCTOR / COMPRESSED MINERAL
INSULATION COPPER SHEATH CABLE (TYPE-MI) TO OBSTRUCTION LIGHT (25-LTG-
7852-01/01M/2M) ON FLARE TOWER LEVEL EL.+83150 AND (25-LTG-7852-
01/01N/2N) ON FLARE TOWER LEVEL EL.+118150.
Nos.
Nos.
M Free issue -
M Free issue -
M Free issue -
M
Nos.
UNIT
Nos
Nos
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos Free issue -
Nos
Nos
Nos
Nos
Nos
Nos
M Free issue -
M Free issue -
M Free issue -
UNIT
M Free issue -
M Free issue -
M Free issue -
M Free issue -
M
- -
MODULE 40 - UTILITY MODULE
INSTRUMENTATION
MODULE 40 (P04) UTILITIES
DESCRIPTION
FLOWMETER, ELECTROMAGNETIC
FLOWMETER, ORIFICE PLATE AND FLANGE SET
FLOWMETER, ROTAMETER INDICATOR
FLOWMETER, DP FLOW TRANSMITTERS WITH 5-VALVE MANIFOLD
FLOWMETER, ULTRASONIC / CORIOLIS WITH INTEGRAL FLOW TRANSMITTER
FLOWMETER, VENTURI
TEMPERATURE GAUGE
TEMPERATURE TRANSMITTERS
RESTRICTION ORIFICE
RUPTURE DISC
PRESSURE SWITCH
PIG SIGNALLER, NON INTRUSIVE
PCS REMOTE CABINET (800 X 800 X 600mm) Ex'e 316L SS CONTROL PANEL WITH SUNSHADE
INSTRUMENT TUBE AND TUBE FITTINGS - E&I Subcontractor TO SUPPLY, CARRY OUT
INSPECTION, INSTALLATION, ITR AND MECH COMPLETION
1/2" OD Tubing- Wall Thickness 0.065 316L SS
1/4" OD Tubing- Wall Thickness 0.049 316L SS
3/8" OD Tubing- Wall Thickness 0.049 316L SS
1/2" OD Tube Union, 316 SS
1/4" OD Tube Union, 316 SS
3/8" OD Tube Union, 316 SS
ELECTRICAL
Cable Ladder & Accessories
ITEM NO DESCRIPTION
EARTH BAR
1.2 50X6MM TINNED PLATED EARTH BAR (300mm TO 450mm LONG)
Earthing accessories
ITEM NO DESCRIPTION
EARTH BAR
1.2 50X6MM TINNED PLATED EARTH BAR (300mm TO 450mm LONG)
NORMAL LIGHTING AND SMALL POWER DISTRIBUTION BOARD, 230V, 3PH, 60Hz,
100A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH
ANTI-CONDENSATION HEATER ,1No.100A, 3P, MCCB FOR INCOMING CABLE, 2Nos.40A, 1
1.1.3 No. 32A,1 No. 25A and 11 Nos. 16A 2P MCBs FOR OUTGOING, 15Nos. (M20) + 1 No.
(M32) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE
(RFOU) AND 7 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUGS.
UPS DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 100A,MINIMUM(IP56), Ex'd', T3, SUITABLE
FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION HEATER,1No.100A, 3P,
MCCB FOR INCOMING CABLE, 6 Nos.16A,9 Nos. 10A, 2P MCBs FOR OUTGOING, 15 Nos.
1.1.29 (M20) + 1 No. (M32) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE
(RFOU) AND 7 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUGS.
LIGHTING JUCTION BOX INCREASED SAFETY Ex'e' IIB T3,IP56 WITH 4 Nos.(M20) CABLE
ENTRIES, 4 Nos. (M20) IP66/67 BRASS NICKEL PLATED CABLE GLAND SUITABLE FOR
1.2.2 TERMINATION OF 3C X 2.5/6 Sq.mm ARMOURED CABLE (TYPE - LV1 / LV2) AND 1No.
(M20) IP66/67 BRASS NICKEL PLATED BLOCKING PLUG.
FLUORESCENT LIGHT FIXTURE IP66/67, Ex 'e', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS
AREA, WITH 2x36W FLOURESCENT LAMP(TL-D 36W/840 OF PHILIPS) 230V, 1PH(LINE TO
LINE), 60Hz, INTEGRAL CONTROL GEAR BOX, 2xM20 CABLE ENTRY AND 2 Nos. (M20)
EX'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS(MAKE
:HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE (RFOU/BFOU ) AND
1 No. (M20)Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUG. (CHALMIT CAT.
REFERENCE: PRGE/236/BI) OR APPROVED EQUIVALENT
2.1.6 BRACKET MOUNTED - MOUNTING BRACKET AND ACCESSORIES (UPS POWER SUPPLY)
2.1.9 SINGLE POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (UPS POWER SUPPLY)
FLUORESCENT LIGHT FIXTURE IP66/67, Ex 'e', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS
AREA, WITH 2x18W FLOURESCENT LAMP(TL-D 18W/840 OF PHILIPS) 230V, 1PH(LINE TO
LINE), 60Hz, INTEGRAL CONTROL GEAR BOX, 2xM20 CABLE ENTRY AND 2 Nos. (M20)
EX'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS(MAKE
:HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE (RFOU/BFOU ) AND
1 No. (M20)Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUG. (CHALMIT CAT.
REFERENCE: PRGE/218/BI) OR APPROVED EQUIVALENT
FLOOD LIGHT FIXTURE - ASYMMETRICAL TYPE IP66/67, Ex 'de', T3, SUITABLE FOR ZONE-1
IIB HAZARDOUS AREA, WITH 400W METAL HALIDE LAMP - 230V, 1PH(LINE TO LINE), 60Hz,
INTEGRAL CONTROL GEAR BOX, 2xM20 CABLE ENTRY AND 2 Nos. (M20) Ex'de' BRASS
NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS (MAKE :HAWKE 501/453/UNIV)
SUITABLE FOR ARMOURED/BRAIDEDCABLE (TYPE - RFOU / BFOU) AND 1 No. (M20) Ex`d'
IP66/67 BRASS NICKEL PLATED BLOCKING PLUG. (CHALMIT CAT. REFERENCE:
EV2D/400/MS/60) OR APPROVED EQUIVALENT
2.3.1 POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (NORMAL POWER SUPPLY)
2.3.2 POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (UPS POWER SUPPLY)
2.3.3 BRACKET MOUNTED - MOUNTING BRACKET AND ACCESSORIES (UPS POWER SUPPLY)
FLOOD LIGHT FIXTURE WITH WIDE BEAM IP66/67, Ex 'de', T3, SUITABLE FOR ZONE-1 IIB
HAZARDOUS AREA, WITH 34W HIGH POWER LIGHT EMITTING DIODES(LEDs) - 230V,
1PH(LINE TO LINE), 60Hz, INTEGRAL CONTROL GEAR BOX,2xM20 CABLE ENTRY AND 2
Nos. (M20) EX'de' BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS
(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE
(RFOU/BFOU) AND 1 No.(M20) Ex'd' IP66/67 BRASS NICKEL PLATED BLOCKING PLUG.
(CHALMIT CAT. REFERENCE: SOLD/034/LE) OR APPROVED EQUIVALENT
2.4.1 BRACKET MOUNTED - MOUNTING BRACKET AND ACCESSORIES (NORMAL POWER SUPPLY)
2.4.2 POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (NORMAL POWER SUPPLY)
2.4.3 BRACKET MOUNTED - MOUNTING BRACKET AND ACCESSORIES (UPS POWER SUPPLY)
2.4.4 POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (UPS POWER SUPPLY)
FLOOD LIGHT FIXTURE WITH WIDE BEAM IP66/67, Ex 'de', T3, SUITABLE FOR ZONE-1 IIB
HAZARDOUS AREA, WITH 125W HIGH POWER LIGHT EMITTING DIODES(LEDs) - 230V,
1PH(LINE TO LINE), 60Hz, INTEGRAL CONTROL GEAR BOX,2xM20 CABLE ENTRY AND 2
Nos. (M20) EX'de' BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS
(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE
(RFOU/BFOU) AND 1 No.(M20) Ex'd' IP66/67 BRASS NICKEL PLATED BLOCKING PLUG.
(CHALMIT CAT. REFERENCE: SOLD/12L/LE) OR APPROVED EQUIVALENT
2.5.1 BRACKET MOUNTED - MOUNTING BRACKET AND ACCESSORIES (NORMAL POWER SUPPLY)
2.5.2 POLE MOUNTED - MOUNTING POLE ACCESSORIES (NORMAL POWER SUPPLY)
2.5.3 BRACKET MOUNTED - MOUNTING BRACKET AND ACCESSORIES (UPS POWER SUPPLY)
2.5.4 POLE MOUNTED - MOUNTING POLE ACCESSORIES (UPS POWER SUPPLY)
POWER SOCKET WITH INTERLOCKING SWITCH AND MATCHING PLUG, 230V, 16A,
1PH(LINE TO LINE),3PIN(2P+E), IP56, Ex`de', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS
AREA. POWER SOCKET: WITH 2xM20 CABLE ENTRIES, 1 No.M20 IP66/67, Ex`de' BRASS
3.1.1 NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS (MAKE :HAWKE 501/453/UNIV)
SUITABLE FOR ARMOURED/BRAIDED CABLE AND 1 No.M20 Ex`d' IP66/67 BRASS NICKEL
PLATED BLOCKING PLUG. POWER PLUG: WITH Ex'd' IP66/67 CABLE GLAND ENTRY
SUTABLE FOR 2Cx6 SQMM EPR/XLPE INSULATED AND BRAIDED FLEXIBLE CABLE .
3.2.2 Ex'd', CONNECTOR PLUG (CP) FROM LVSR (HAWKE CAT. REF. Ex'd-32-N-CP-B-1-95-S-FPC-A)
WELDING RECEPTACLE WITH INTERLOCKING SWITCH AND MATCHING PLUG, 440V, 60Hz,
63A, 3PH, 4PIN (3P+PE), IP56, Ex`de', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH 2XM40 CABLE ENTRIES, AND TERMINALS SUITABLE FOR 3CX50SQMM CABLES, 2
4.1.1 Nos. IP66/67, Ex`d BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS
SUITABLE FOR ARMOURED CABLE AND 1 No. Ex`d' IP66/67 BRASS NICKEL PLATED
BLOCKING PLUG.
5.0 ELECTRICAL POWER JUNCTION BOX
5.1.1 ELECTRICAL POWER JUNCTION BOX
ELECTRICAL JUNCTION BOX, SS316L, IP 66 Ex`d', T3, SUITABLE FOR ZONE-1 IIB
HAZARDOUS AREA, WITH EXTERNAL BRASS EARTHING STUD AND 1No.(M20) CABLE
ENTRY AND 1No.(M20) IP66/67 Ex'd' BRASS NICKEL PLATED DOUBLE COMPRESSION
CABLE GLANDS SUITABLE FOR 2C x 6sq.mm x LPF/EPR INSULATED FIRE RESISTANT (MGT)
AND ARMOURED CABLE FROM MODULE - 20 EMERGENCY LIGHTING DB AND 1No.(M20)
6.1.1 CABLE ENTRY WITH Ex`d' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLAND SUITABLE FOR 2C X 4sq.mm HEAVY DUTY TYPE COPPER CONDUCTOR /
COMPRESSED MINERAL INSULATION COPPER SHEATH CABLE (TYPE-MI) TO OBSTRUCTION
LIGHT (25-LTG-7852-01/01M/2M) ON FLARE TOWER LEVEL EL.+83150 AND (25-LTG-7852-
01/01N/2N) ON FLARE TOWER LEVEL EL.+118150.
Total
Materials E&I Intallation
UNIT UOM Unit rates Total rates Unit rate Total Rates
Nos.
13 Nos. Free issue -
18 Nos. Free issue -
Nos.
3 Nos. Free issue -
Nos.
Nos.
Nos.
3 Nos. Free issue -
Nos.
Nos.
8 Nos. Free issue -
9 Nos. Free issue -
Nos.
2 Nos. Free issue -
2 Nos. Free issue -
3 Nos. Free issue -
Nos.
6 Nos. - -
3 Nos. - -
1 Nos. - -
45 Nos. - -
21 Nos. - -
12 Nos. - -
11 Nos. - -
360 metre - -
27 Nos. - -
96 Nos. - -
60 Nos. - -
9 Nos. - -
16 Nos. - -
120 Nos. - -
32 Nos. - -
Nos.
metre
Nos.
4 Nos. - -
32 Nos. - -
14 Nos. - -
60 Mtr - -
100 Mtr - -
100 Mtr - -
4 nos - -
4 nos - -
240 Mtr - -
120 Mtr - -
60 Mtr - -
75 Mtr - -
0 Mtr
0 Mtr
1800 Mtr - -
75 Mtr - -
Mtr
360 Mtr - -
120 Mtr - -
600 Mtr - -
500 Mtr - -
76 Mtr - -
178 Mtr - -
89 Nos. - -
144 Nos. - -
6 Nos. - -
0 Nos.
24 Nos. - -
8 Nos. - -
475 Mtr - -
48 Nos. - -
40 Nos. - -
0 Mtr
0 Mtr
MODULE 40 UNIT
Nos.
212 M Free issue -
139 M Free issue -
78 M Free issue -
M
Nos.
MODULE 40 UNIT
Nos.
Nos.
MODULE 40 UNIT
Nos
Nos
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
1 Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
1 Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
6 Nos. Free issue
-
1 Nos Free issue
-
9 Nos Free issue -
Nos
Nos
Nos
Nos
-
3 Nos Free issue -
1 Nos Free issue -
1 Nos Free issue -
Nos
Nos
Nos
Nos
-
1 Nos Free issue -
Nos
3 Nos Free issue -
Nos
-
4 Nos Free issue -
2 Nos Free issue -
3 Nos Free issue -
Nos
Nos
Nos
Nos
Nos
Nos
Nos
-
Nos.
Nos.
M
M
MODULE 40 UNIT
- -
MODULE 50 - CHEMICAL INJECTION MODULE
INSTRUMENTATION
Lighting and Small Power Cables
ITEM No.
ITEM No.
1.1
1.1.1
1.1.2
1.2
1.2.1
1.2.2
1.2.3
MODULE 50 - CHEMICAL INJECTION MODULE
INSTRUMENTATION
MODULE 50 (S04) CHEMICAL INJECTION
DESCRIPTION
FLOWMETER, ELECTROMAGNETIC
FLOWMETER, ORIFICE PLATE AND FLANGE SET
FLOWMETER, ROTAMETER INDICATOR
FLOWMETER, DP FLOW TRANSMITTERS WITH 5-VALVE MANIFOLD
FLOWMETER, ULTRASONIC / CORIOLIS WITH INTEGRAL FLOW TRANSMITTER
FLOWMETER, VENTURI
TEMPERATURE GAUGE
TEMPERATURE TRANSMITTERS
RESTRICTION ORIFICE
RUPTURE DISC
PRESSURE SWITCH
PIG SIGNALLER, NON INTRUSIVE
PCS REMOTE CABINET (800 X 800 X 600mm) Ex'e 316L SS CONTROL PANEL WITH SUNSHADE
JUNCTION BOXES - E&I Subcontractor TO SUPPLY, CARRY OUT INSPECTION, INSTALLATION, ITR AND MECH COMPLETION
INSTRUMENT AIR SUPPPLY ITEMS - E&I Subcontractor TO SUPPLY, CARRY OUT INSPECTION, INSTALLATION, ITR AND MECH
COMPLETION
INSTRUMENT AIR HEADER / SUBHEADER - by piping
INSTRUMENT AIR MANIFOLD (8 way)
1/2" BALL VALVES FOR MANIFOLD
1/2" BALL VALVES FOR FIELD INSTR
CABLE LADDER AND ACCESSORIES - E&I Subcontractor TO SUPPLY, CARRY OUT INSPECTION, INSTALLATION, ITR AND MECH
COMPLETION
INSTRUMENT CABLES - E&I Subcontractor TO SUPPLY, CARRY OUT INSPECTION, INSTALLATION, ITR AND MECH COMPLETION
(LV Cables 600V/1000V - Instrument Power)
2C X 2.5mm² IEC 60331
4C X 2.5mm² IEC 60331
12C X 2.5mm² IEC 60332
(Instrument & Communication Cables - Individual and Collective Screened cables)
1Pr X 1.5mm² IEC 60332
2Pr X 1.5mm² IEC 60332
5Pr X 1.0mm² IEC 60332
10Pr X 1.0mm² IEC 60332
20Pr X 1.0mm² IEC 60332
(Fire/Gas & Communication Cables - Individual and Collective Screened cables)
1Tr X 1.5mm² IEC 60331
1Pr X 1.5mm² IEC 60331
(Earthing Materials - Instrumentation)
EARTH CABLE - 6 SQ.MM
EARTH CABLE - 25 SQ.MM
EARTH BOSS ; M10 X 40MM DIA X 35MM LG. CW/ ACCESSORIES
(Glanding & Termination - Instrumentation)
1Pr X 1.5mm²
2Pr X 1.5mm²
5Pr X 1.0mm²
10Pr X 1.0mm²
20Pr X 1.0mm²
1Pr X 1.5mm²
1Tr X 1.5mm²
2C X 2.5mm²
4C X 2.5mm²
12C X 2.5mm²
DESCRIPTION
DESCRIPTION
Total
UNIT UOM Materials E&I Intallation
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
12 Nos. Free Issue -
Nos.
Nos.
6 Nos. Free Issue -
6 Nos. Free Issue -
3 Nos. Free Issue -
Nos.
1 Nos. - -
2 Nos. - -
1 Nos. - -
3 Nos. - -
24 Nos. - -
17 Nos. - -
5 Nos. - -
0 metre - -
0 Nos. - -
0 Nos. - -
0 Nos. - -
0 Nos. - -
0 Nos. - -
0 Nos. - -
0 Nos. - -
Nos.
metre
Nos.
1 Nos. - -
8 Nos. - -
1 Nos. - -
60 Mtr - -
100 Mtr - -
100 Mtr - -
4 nos - -
4 nos - -
240 Mtr - -
120 Mtr - -
60 Mtr - -
0 Mtr - -
0 Mtr - -
0 Mtr - -
0 Mtr - -
0 Mtr - -
Mtr
120 Mtr - -
120 Mtr - -
675 Mtr - -
725 Mtr - -
0 Mtr - -
98 Mtr - -
49 Nos. - -
0 Nos. - -
0 Nos. - -
0 Nos. - -
8 Nos. - -
8 Nos. - -
675 Mtr - -
54 Nos. - -
58 Nos. - -
0 Mtr - -
0 Mtr - -
MODULE 50 UNIT
MODULE 50 UNIT
- -
PIPERACK 101 to 108
ELECTRICAL
Cable Ladder & Accessories
EARTH BAR
1.2 50X6MM TINNED PLATED EARTH BAR (300mm TO 450mm LONG)
Earthing accessories
EARTH BAR
1.2 50X6MM TINNED PLATED EARTH BAR (300mm TO 450mm LONG)
LIGHTING JUCTION BOX INCREASED SAFETY Ex'e' IIB T3,IP56 WITH 3 Nos.
(M20) CABLE ENTRIES, 3 Nos. (M20) Ex'de' IP66/67 BRASS NICKEL PLATED
1.2.1 CABLE GLAND (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR TERMINATION 9
OF 2C X 2.5/6 Sq.mm ARMOURED CABLE (TYPE -RFOU /BFOU) AND 1No.
(M20) Ex'd' IP66/67 BRASS NICKEL PLATED BLOCKING PLUG.
LIGHTING JUCTION BOX INCREASED SAFETY Ex'e' IIB T3,IP56 WITH 4 Nos.
(M20) CABLE ENTRIES, 4 Nos. (M20) IP66/67 BRASS NICKEL PLATED CABLE
1.2.2 GLAND SUITABLE FOR TERMINATION OF 3C X 2.5/6 Sq.mm ARMOURED
CABLE (TYPE - LV1 / LV2) AND 1No. (M20) IP66/67 BRASS NICKEL PLATED
BLOCKING PLUG.
FLUORESCENT LIGHT FIXTURE IP66/67, Ex 'e', T3, SUITABLE FOR ZONE-1 IIB
HAZARDOUS AREA, WITH 2x36W FLOURESCENT LAMP(TL-D 36W/840 OF
PHILIPS) 230V, 1PH(LINE TO LINE), 60Hz, INTEGRAL CONTROL GEAR BOX,
2xM20 CABLE ENTRY AND 2 Nos. (M20) EX'de' IP66/67 BRASS NICKEL
3
PLATED DOUBLE COMPRESSION CABLE GLANDS(MAKE :HAWKE
501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE (RFOU/BFOU )
AND 1 No. (M20)Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUG.
(CHALMIT CAT. REFERENCE: PRGE/236/BI) OR APPROVED EQUIVALENT
FLUORESCENT LIGHT FIXTURE IP66/67, Ex 'e', T3, SUITABLE FOR ZONE-1 IIB
HAZARDOUS AREA, WITH 2x18W FLOURESCENT LAMP(TL-D 18W/840 OF
PHILIPS) 230V, 1PH(LINE TO LINE), 60Hz, INTEGRAL CONTROL GEAR BOX,
2xM20 CABLE ENTRY AND 2 Nos. (M20) EX'de' IP66/67 BRASS NICKEL
PLATED DOUBLE COMPRESSION CABLE GLANDS(MAKE :HAWKE
501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE (RFOU/BFOU )
AND 1 No. (M20)Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUG.
(CHALMIT CAT. REFERENCE: PRGE/218/BI) OR APPROVED EQUIVALENT
2.3.1 POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (NORMAL POWER SUP 2
2.3.2 POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (UPS POWER SUPPLY)
2.3.3 BRACKET MOUNTED - MOUNTING BRACKET AND ACCESSORIES (UPS POWER SUPPLY)
FLOOD LIGHT FIXTURE WITH WIDE BEAM IP66/67, Ex 'de', T3, SUITABLE FOR
ZONE-1 IIB HAZARDOUS AREA, WITH 34W HIGH POWER LIGHT EMITTING
DIODES(LEDs) - 230V, 1PH(LINE TO LINE), 60Hz, INTEGRAL CONTROL GEAR
BOX,2xM20 CABLE ENTRY AND 2 Nos. (M20) EX'de' BRASS NICKEL PLATED 7
DOUBLE COMPRESSION CABLE GLANDS (MAKE :HAWKE 501/453/UNIV)
SUITABLE FOR ARMOURED/BRAIDED CABLE (RFOU/BFOU) AND 1 No.(M20)
Ex'd' IP66/67 BRASS NICKEL PLATED BLOCKING PLUG. (CHALMIT CAT.
REFERENCE: SOLD/034/LE) OR APPROVED EQUIVALENT
FLOOD LIGHT FIXTURE WITH WIDE BEAM IP66/67, Ex 'de', T3, SUITABLE FOR
ZONE-1 IIB HAZARDOUS AREA, WITH 125W HIGH POWER LIGHT EMITTING
DIODES(LEDs) - 230V, 1PH(LINE TO LINE), 60Hz, INTEGRAL CONTROL GEAR
BOX,2xM20 CABLE ENTRY AND 2 Nos. (M20) EX'de' BRASS NICKEL PLATED 5
DOUBLE COMPRESSION CABLE GLANDS (MAKE :HAWKE 501/453/UNIV)
SUITABLE FOR ARMOURED/BRAIDED CABLE (RFOU/BFOU) AND 1 No.(M20)
Ex'd' IP66/67 BRASS NICKEL PLATED BLOCKING PLUG. (CHALMIT CAT.
REFERENCE: SOLD/12L/LE) OR APPROVED EQUIVALENT
Total
Materials E&I Intallation
Nos.
Nos.
M Free Issue -
M Free Issue -
M
M
Nos.
UNIT
Nos.
Nos.
M Free Issue -
M Free Issue -
M
M
Nos.
UNIT
Nos
Nos
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos Free Issue -
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos.
Nos.
M
M
UNIT
M Free Issue -
M Free Issue -
M Free Issue -
M Free Issue -
M
- -
HELIDECK
The helideck SHALL comply with IMO MODU Code, ICAO ANNEX 14 VOL II and UK Civil Aviation
Authority publication CAP 437 Offshore Helicopter Landing Areas - Guidance on Standards, and
Company Aviation Standard.
Main Characteristics
following requirements (based on S92 helicopter type):
The helideck SHALL, as minimum comply with the
• Certified as per UK Civil Aviation Authority publication CAP 437
Offshore Helicopter Landing Areas - Guidance on Standards or
equivalent
• D value 20 m
• t Value 11 t (dynamic impact as per ICAO definition)
• Tiedown points: available as specified in ICAO ANNEX 14/CAP437
• Drainage: be present. Appropriate drainage system from helideck
into safe storage place
• Helideck painting/daylight visual markings: standard as ICAO ANNEX
14/CAP 437.
• Friction Capability: not less than 0,65 (last friction test available)
• Surface landing net: be provided
• Perimeter landing net: as specified on CAP 437/UKOOA
• Helideck lighting: perimeter, flood, windsock and general
lighting (also connected to UPS) as specified on ICAO ANNEX 14/Cap
437
• Obstruction on helideck: less than 25 cm height
• Obstruction on 150° obstacle sector: as specified on ICAO ANNEX
14/Cap 437
• Obstruction on 210° obstacle free sector: as specified on ICAO
ANNEX 14/Cap 437
• Helideck Status or warning light/s: present ICAO ANNEX 14/Cap 437
• Refuelling unit: as specified by Regulation (CAP 437,ICAO,OGP)
• Access points: not less than 2
• Emergency Exit: one
• Fire protection systems: as specified by ICAO ANNEX 14/Cap
437for H2 helidecks
• Rescue Equipment/PPI: not less than specified on ICAO ANNEX
14/Cap 437CAP 437
• Radio Equipment: VHF main plus portable, NDB (non directional
beacon)
• Weather Equipment: meteo station be present (anemometer, air
temp, barometer, general visibility and cloud base)
• Helideck Crew: 1HLO, 2HDA, 2firefighting personnel (OPITO
standard course)
Bill of Quantities
Description Qty
Helideck Primary 150
Helideck Safety Net Supply and Install 1
Helideck Safety Rope Supply and Install 1
Helideck – H Circle and H Illuminated Lights 1
Perimeter and Status Lights 1
Helideck Painting 1500
UOM
Ton
Lot
Lot
Lot
Lot
M2