Вы находитесь на странице: 1из 95

Material Installation

SUMMARY USD USD


MODULE 25( Flare Tower) - -
MODULE 40 - UTILITY MODULE - -
MODULE 50 - CHEMICAL INJECTION MODULE - -
PIPERACK 101 to 108 - -
MODULE 25( Flare Tower)

ELECTRICAL
Earthing accessories

MODULE
ITEM NO DESCRIPTION 25

1.0 EARTHING ACCESSORIES


1.1 EARTH BOSS

1.1.1 50MM DIA -STAINLESS STEEL EARTHING BOSS C/W M10 STAINLESS STEEL STUD, 70
WASHER AND NUTS.
40MM DIA -STAINLESS STEEL EARTHING BOSS C/W M10 STAINLESS STEEL STUD,
1.1.2 WASHER AND NUTS.

EARTH BAR

1.2 50X6MM TINNED PLATED EARTH BAR (300mm TO 450mm LONG)

1.3 EARTHING CABLES


STRANDED COPPER CONDUCTOR, LOW SMOKE ZERO HALOGEN THERMOSET
COMPOUND INSULATED,INCLUSIVE OF NECESSARY COMPRESSION TYPE COPPER
LUGS COMPLETE WITH SS316L BOLTS, NUTS, FLAT WASHERS AND SPRING
WASHERS.
COLOUR: GREEN WITH YELLOW STRIPE.
1.3.1 1C X 6MM² 22
1.3.2 1C X 25MM² 76
1.3.3 1C X 70MM² 14
1.3.4 1C X 120MM²
1C X 70mm² EARTHING CABLE FOR PRE-COMMISSIONING/COMMISSIONING
1.3.5 EQUIPMENT.
1.3.6 SS136L CROCODILE CLIP SUITABLE FOR 70mm² EARTHING CABLE

Lighting Fixtures & Small Power receptacles, Welding Sockets


MODULE
ITEM No. DESCRIPTION 25

1.0 DISTRIBUTION BOARDS AND ACCESSORIES


1.1 LIGHTING DISTRIBUTION BOARD
NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,
63A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER ,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 18Nos.16A, 2P MCBs FOR OUTGOING, 18Nos. (M20) + 1 No. (M50)
1.1.1 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED
CABLE (RFOU) AND 4 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED
BLOCKING PLUGS.

NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER ,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 18Nos.16A, 2P MCBs FOR OUTGOING, 18Nos. (M20) + 1 No. (M32)
1.1.2 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED
CABLE (RFOU) AND 6 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED
BLOCKING PLUGS.

NORMAL LIGHTING AND SMALL POWER DISTRIBUTION BOARD, 230V, 3PH,


60Hz, 100A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS
AREA, WITH ANTI-CONDENSATION HEATER ,1No.100A, 3P, MCCB FOR
INCOMING CABLE, 2Nos.40A, 1 No. 32A,1 No. 25A and 11 Nos. 16A 2P MCBs
1.1.3 FOR OUTGOING, 15Nos. (M20) + 1 No. (M32) Ex'de' IP66/67 BRASS NICKEL
PLATED DOUBLE COMPRESSION CABLE GLANDS(MAKE :HAWKE 501/453/UNIV)
SUITABLE FOR ARMOURED/BRAIDED CABLE (RFOU) AND 7 Nos. (M20) Ex`d'
IP66/67 BRASS NICKEL PLATED BLOCKING PLUGS.

NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER ,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 15Nos.16A, 2P MCBs FOR OUTGOING, 15Nos. (M20) + 1 No. (M40)
1.1.4 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED
CABLE (RFOU) AND 6 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED
BLOCKING PLUGS.

NORMAL POWER DISTRIBUTION BOARD, 440V, 3PH, 60Hz,


250A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER ,1No.100A, 3P, MCCB FOR INCOMING
CABLE, 5 Nos.100A MCCBs FOR OUTGOING, 5Nos. (M63) + 1 No. (GLAND
1.1.5 SUITABLE FOR 3RX1CX120 sq.mm CABLES) Ex'de' IP66/67 BRASS NICKEL PLATED
DOUBLE COMPRESSION CABLE GLANDS(MAKE :HAWKE 501/453/UNIV)
SUITABLE FOR ARMOURED/BRAIDED CABLE (RFOU) AND 4 Nos. (M63) Ex`d'
IP66/67 BRASS NICKEL PLATED BLOCKING PLUGS.
NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,
63A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER ,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 18Nos.16A, 2P MCBs FOR OUTGOING, 18Nos. (M20) + 1 No. (M50)
1.1.6 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED
CABLE (RFOU) AND 3 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED
BLOCKING PLUGS.

NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER ,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 12Nos.16A, 2P MCBs FOR OUTGOING, 12Nos. (M20) + 1 No. (M40)
1.1.7 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED
CABLE (RFOU) AND 5 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED
BLOCKING PLUGS.

NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER ,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 21Nos.16A, 2P MCBs FOR OUTGOING, 21 Nos. (M20) + 1 No. (M40)
1.1.8 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED
CABLE (RFOU) AND 6 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED
BLOCKING PLUGS.

NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER ,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 12Nos.16A, 2P MCBs FOR OUTGOING, 12 Nos. (M20) + 1 No. (M32)
1.1.9 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED
CABLE (RFOU) AND 5 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED
BLOCKING PLUGS.
NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,
63A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER ,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 21 Nos.16A, 2P MCBs FOR OUTGOING, 21 Nos. (M20) + 1 No. (M50)
1.1.10 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED
CABLE (RFOU) AND 3 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED
BLOCKING PLUGS.

NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER ,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 12 Nos.16A, 2P MCBs FOR OUTGOING, 12 Nos. (M20) + 1 No. (M50)
1.1.11 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED
CABLE (RFOU) AND 3 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED
BLOCKING PLUGS.

NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER ,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 21 Nos.16A, 2P MCBs FOR OUTGOING, 21 Nos. (M20) + 1 No. (M32)
1.1.12 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED
CABLE (RFOU) AND 5 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED
BLOCKING PLUGS.

NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER ,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 21 Nos.16A, 2P MCBs FOR OUTGOING, 21 Nos. (M20) + 1 No. (M50)
1.1.13 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED
CABLE (RFOU) AND 5 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED
BLOCKING PLUGS.

NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER ,1No.63A, 3P, MCCB FOR INCOMING
1.1.14 CABLE, 18 Nos.16A, 2P MCBs FOR OUTGOING, 18 Nos. (M20) + 1 No. (M50)
Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED
CABLE (RFOU) AND 6 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED
BLOCKING PLUGS.
EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,
63A,MINIMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 12Nos.16A, 2P MCBs FOR OUTGOING, 12Nos. (M20) + 1 No. (M40)
1.1.15 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS
(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE
(BFOU) AND 8 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING
PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINIMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 15Nos.16A, 2P MCBs FOR OUTGOING, 15Nos. (M20) + 1 No. (M32)
1.1.16 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS
(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE
(BFOU) AND 3 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING
PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINIMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 18Nos.16A, 2P MCBs FOR OUTGOING, 18Nos. (M20) + 1 No. (M40)
1.1.17 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS
(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE
(BFOU) AND 4 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING
PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINIMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 12Nos.16A, 2P MCBs FOR OUTGOING, 12Nos. (M20) + 1 No. (M40)
1.1.18 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS
(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE
(BFOU) AND 6 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING
PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINIMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER,1No.63A, 3P, MCCB FOR INCOMING
1.1.19 CABLE, 9Nos.16A, 2P MCBs FOR OUTGOING, 9 Nos. (M20) + 1 No. (M40) Ex'de'
IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS
(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE
(BFOU) AND 5 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING
PLUGS.
EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,
63A,MINIMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 24 Nos.16A, 2P MCBs FOR OUTGOING, 24 Nos. (M20) + 1 No. (M40)
1.1.20 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS
(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE
(BFOU) AND 3 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING
PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINIMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 18 Nos.16A, 2P MCBs FOR OUTGOING, 18 Nos. (M20) + 1 No. (M50)
1.1.21 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS
(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE
(BFOU) AND 4 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING
PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINIMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 18 Nos.16A, 2P MCBs FOR OUTGOING, 18 Nos. (M20) + 1 No. (M50)
1.1.22 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS
(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE
(BFOU) AND 3 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING
PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINIMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 9Nos.16A, 2P MCBs FOR OUTGOING, 9 Nos. (M20) + 1 No. (M32) Ex'de'
1.1.23 IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS
(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE
(BFOU) AND 5 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING
PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINIMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER,1No.63A, 3P, MCCB FOR INCOMING
1.1.24 CABLE, 18Nos.16A, 2P MCBs FOR OUTGOING, 18 Nos. (M20) + 1 No. (M32)
Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS
(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE
(BFOU) AND 5 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING
PLUGS.
EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,
63A,MINIMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 15 Nos.16A, 2P MCBs FOR OUTGOING, 15 Nos. (M20) + 1 No. (M40)
1.1.25 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS
(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE
(BFOU) AND 3 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING
PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINIMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 15 Nos.16A, 2P MCBs FOR OUTGOING, 15 Nos. (M20) + 1 No. (M32)
1.1.26 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS
(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE
(BFOU) AND 4 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING
PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINIMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 18Nos.16A, 2P MCBs FOR OUTGOING, 18 Nos. (M20) + 1 No. (M50)
1.1.27 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS
(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE
(BFOU) AND 6 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING
PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINIMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 21Nos.16A, 2P MCBs FOR OUTGOING, 21 Nos. (M20) + 1 No. (M40)
1.1.28 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS
(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE
(BFOU) AND 4 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING
PLUGS.

UPS DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 100A,MINIMUM(IP56), Ex'd', T3,


SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION
HEATER,1No.100A, 3P, MCCB FOR INCOMING CABLE, 6 Nos.16A,9 Nos. 10A, 2P
1.1.29 MCBs FOR OUTGOING, 15 Nos. (M20) + 1 No. (M32) Ex'de' IP66/67 BRASS
NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS (MAKE :HAWKE
501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE (RFOU) AND 7 Nos.
(M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUGS.
ESSENTIAL DISTRIBUTION BOARD, 440V, 3PH, 60Hz, 250A,MINMUM(IP56),
Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-
CONDENSATION HEATER ,1No.100A, 3P, MCCB FOR INCOMING CABLE, 5
Nos.100A MCCBs FOR OUTGOING, 5Nos. (M63) + 1 No. (GLAND SUITABLE FOR
1.1.30 3RX1CX120 sq.mm CABLES) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE
COMPRESSION CABLE GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (RFOU) AND 4 Nos. (M63) Ex`d' IP66/67 BRASS
NICKEL PLATED BLOCKING PLUGS.

1.2 LIGHTING JUNCTION BOX

LIGHTING JUCTION BOX INCREASED SAFETY Ex'e' IIB T3,IP56 WITH 3 Nos.(M20)
CABLE ENTRIES, 3 Nos. (M20) Ex'de' IP66/67 BRASS NICKEL PLATED CABLE
1.2.1 GLAND (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR TERMINATION OF 2C X 2
2.5/6 Sq.mm ARMOURED CABLE (TYPE -RFOU /BFOU) AND 1No. (M20) Ex'd'
IP66/67 BRASS NICKEL PLATED BLOCKING PLUG.

LIGHTING JUCTION BOX INCREASED SAFETY Ex'e' IIB T3,IP56 WITH 4 Nos.(M20)
CABLE ENTRIES, 4 Nos. (M20) IP66/67 BRASS NICKEL PLATED CABLE GLAND
1.2.2 SUITABLE FOR TERMINATION OF 3C X 2.5/6 Sq.mm ARMOURED CABLE (TYPE -
LV1 / LV2) AND 1No. (M20) IP66/67 BRASS NICKEL PLATED BLOCKING PLUG.

2.0 LIGHT FIXTURES AND ACCESSORIES


2.1 FLUORESCENT LIGHT FIXTURES(2X36W)

FLUORESCENT LIGHT FIXTURE IP66/67, Ex 'e', T3, SUITABLE FOR ZONE-1 IIB
HAZARDOUS AREA, WITH 2x36W FLOURESCENT LAMP(TL-D 36W/840 OF
PHILIPS) 230V, 1PH(LINE TO LINE), 60Hz, INTEGRAL CONTROL GEAR BOX, 2xM20
CABLE ENTRY AND 2 Nos. (M20) EX'de' IP66/67 BRASS NICKEL PLATED DOUBLE
COMPRESSION CABLE GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (RFOU/BFOU ) AND 1 No. (M20)Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUG. (CHALMIT CAT. REFERENCE:
PRGE/236/BI) OR APPROVED EQUIVALENT

BRACKET MOUNTED - MOUNTING BRACKET AND ACCESSORIES (NORMAL


2.1.1 POWER SUPPLY)

2.1.2 SUSPENSION MOUNTED - MOUNTING ACCESSORIES (NORMAL POWER SUPPLY)

DOUBLE POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (NORMAL


2.1.3 POWER SUPPLY)
SINGLE POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (NORMAL
2.1.4 POWER SUPPLY)
2.1.5 HANDRAIL MOUNTED - ACCESSORIES (NORMAL POWER SUPPLY)
BRACKET MOUNTED - MOUNTING BRACKET AND ACCESSORIES (UPS POWER
2.1.6 SUPPLY)
2.1.7 SUSPENSION MOUNTED - MOUNTING ACCESSORIES (UPS POWER SUPPLY)

DOUBLE POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (NORMAL


2.1.8 POWER SUPPLY)
SINGLE POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (UPS POWER
2.1.9 SUPPLY)
2.1.10 HANDRAIL MOUNTED - ACCESSORIES (UPS POWER SUPPLY)

2.2 FLUORESCENT LIGHT FIXTURES(2X18W)

FLUORESCENT LIGHT FIXTURE IP66/67, Ex 'e', T3, SUITABLE FOR ZONE-1 IIB
HAZARDOUS AREA, WITH 2x18W FLOURESCENT LAMP(TL-D 18W/840 OF
PHILIPS) 230V, 1PH(LINE TO LINE), 60Hz, INTEGRAL CONTROL GEAR BOX, 2xM20
CABLE ENTRY AND 2 Nos. (M20) EX'de' IP66/67 BRASS NICKEL PLATED DOUBLE
COMPRESSION CABLE GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (RFOU/BFOU ) AND 1 No. (M20)Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUG. (CHALMIT CAT. REFERENCE:
PRGE/218/BI) OR APPROVED EQUIVALENT

2.2.1 HANDRAIL MOUNTED - MOUNTING ACCESSORIES (NORMAL POWER SUPPLY)

2.2.2 HANDRAIL MOUNTED - MOUNTING ACCESSORIES (UPS POWER SUPPLY)

2.2.3 SUSPENSION MOUNTED - MOUNTING ACCESSORIES (UPS POWER SUPPLY)

2.3 FLOOD LIGHT FIXTURES - 400W (WIDE BEAM)

FLOOD LIGHT FIXTURE - ASYMMETRICAL TYPE IP66/67, Ex 'de', T3, SUITABLE


FOR ZONE-1 IIB HAZARDOUS AREA, WITH 400W METAL HALIDE LAMP - 230V,
1PH(LINE TO LINE), 60Hz, INTEGRAL CONTROL GEAR BOX, 2xM20 CABLE ENTRY
AND 2 Nos. (M20) Ex'de' BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE 1
GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDEDCABLE (TYPE - RFOU / BFOU) AND 1 No. (M20) Ex`d'
IP66/67 BRASS NICKEL PLATED BLOCKING PLUG. (CHALMIT CAT. REFERENCE:
EV2D/400/MS/60) OR APPROVED EQUIVALENT

POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (NORMAL POWER


2.3.1 SUPPLY)

2.3.2 POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (UPS POWER SUPPLY)

BRACKET MOUNTED - MOUNTING BRACKET AND ACCESSORIES (UPS POWER


2.3.3 1
SUPPLY)

2.4 LED FLOOD LIGHT FIXTURE (34W)-WIDE BEAM


FLOOD LIGHT FIXTURE WITH WIDE BEAM IP66/67, Ex 'de', T3, SUITABLE FOR
ZONE-1 IIB HAZARDOUS AREA, WITH 34W HIGH POWER LIGHT EMITTING
DIODES(LEDs) - 230V, 1PH(LINE TO LINE), 60Hz, INTEGRAL CONTROL GEAR
BOX,2xM20 CABLE ENTRY AND 2 Nos. (M20) EX'de' BRASS NICKEL PLATED 4
DOUBLE COMPRESSION CABLE GLANDS (MAKE :HAWKE 501/453/UNIV)
SUITABLE FOR ARMOURED/BRAIDED CABLE (RFOU/BFOU) AND 1 No.(M20)
Ex'd' IP66/67 BRASS NICKEL PLATED BLOCKING PLUG. (CHALMIT CAT.
REFERENCE: SOLD/034/LE) OR APPROVED EQUIVALENT

BRACKET MOUNTED - MOUNTING BRACKET AND ACCESSORIES (NORMAL


2.4.1 2
POWER SUPPLY)
POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (NORMAL POWER
2.4.2 SUPPLY)
BRACKET MOUNTED - MOUNTING BRACKET AND ACCESSORIES (UPS POWER
2.4.3 2
SUPPLY)

2.4.4 POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (UPS POWER SUPPLY)

2.5 LED FLOOD LIGHT FIXTURE (125W)-WIDE BEAM

FLOOD LIGHT FIXTURE WITH WIDE BEAM IP66/67, Ex 'de', T3, SUITABLE FOR
ZONE-1 IIB HAZARDOUS AREA, WITH 125W HIGH POWER LIGHT EMITTING
DIODES(LEDs) - 230V, 1PH(LINE TO LINE), 60Hz, INTEGRAL CONTROL GEAR
BOX,2xM20 CABLE ENTRY AND 2 Nos. (M20) EX'de' BRASS NICKEL PLATED
DOUBLE COMPRESSION CABLE GLANDS (MAKE :HAWKE 501/453/UNIV)
SUITABLE FOR ARMOURED/BRAIDED CABLE (RFOU/BFOU) AND 1 No.(M20)
Ex'd' IP66/67 BRASS NICKEL PLATED BLOCKING PLUG. (CHALMIT CAT.
REFERENCE: SOLD/12L/LE) OR APPROVED EQUIVALENT

BRACKET MOUNTED - MOUNTING BRACKET AND ACCESSORIES (NORMAL


2.5.1 POWER SUPPLY)

2.5.2 POLE MOUNTED - MOUNTING POLE ACCESSORIES (NORMAL POWER SUPPLY)

BRACKET MOUNTED - MOUNTING BRACKET AND ACCESSORIES (UPS POWER


2.5.3 SUPPLY)
2.5.4 POLE MOUNTED - MOUNTING POLE ACCESSORIES (UPS POWER SUPPLY)

2.6 AERONAUTICAL OBSTRUCTION LIGHT


MEDIUM INTENSITY, ICAO TYPE C (STEADY BURNING, RED COLOUR)
AERONAUTICAL OBSTRUCTION LIGHT COVERED WITH HEAT SHIELD Ex`d' IIC T6,
IP66 SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH 35W LED LIGHT 230V,
1PH, 60Hz, INTEGRAL CONTROL GEAR BOX, 2xM20 CABLE ENTRY AND 2 Nos.
(M20) Ex`d' BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS
2.6.1 4
SUITABLE FOR 2C X 4sq.mm HEAVY DUTY TYPE COPPER CONDUCTOR /
COMPRESSED MINERAL INSULATION COPPER SHEATH CABLE (TYPE-MI) WITH
BLOCKING PLUG. (CLAMP CATALOGUE REFERENCE : SEGS23C2K (MEDIUM
INTENSITY TYPE) OR APPROVED EQUIVALENT.

2.7 HEAT SHIELD FOR OBSTRUCTION LIGHT:


HEAT SHIELD (POINT LIGHTING CATALOGUE REF : PL40139-SS) OR APPROVED
EQUIVALENT.
2.7.1 4

3.0 SOCKET OUTLETS & PLUGS


3.1 16A OUTDOOR POWER SOCKET

POWER SOCKET WITH INTERLOCKING SWITCH AND MATCHING PLUG, 230V,


16A, 1PH(LINE TO LINE),3PIN(2P+E), IP56, Ex`de', T3, SUITABLE FOR ZONE-1 IIB
HAZARDOUS AREA. POWER SOCKET: WITH 2xM20 CABLE ENTRIES, 1 No.M20
IP66/67, Ex`de' BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS
3.1.1 (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE
AND 1 No.M20 Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUG. POWER
PLUG: WITH Ex'd' IP66/67 CABLE GLAND ENTRY SUTABLE FOR 2Cx6 SQMM
EPR/XLPE INSULATED AND BRAIDED FLEXIBLE CABLE .

3.2 LVSR CONNECTORS & RECEPTACLES FOR PIGTAIL CONNECTIONS


CONNECTOR PLUG (CP) WITH CAP
Ex'd', CONNECTOR PLUG (CP) FROM LVSR (HAWKE CAT. REF. Ex'd-32-N-CP-B-1-
3.2.1 120-S-FPC-A)
Ex'd', CONNECTOR PLUG (CP) FROM LVSR (HAWKE CAT. REF. Ex'd-32-N-CP-B-1-
3.2.2 95-S-FPC-A)

CONNECTOR RECEPTACLES (CR) WITH CAP


Ex'd', CONNECTOR PLUG (CR) TO DISTRIBUTION BOARD (HAWKE CAT. REF. Ex'd-
3.2.3 32-N-CR-B-1-120-P-FRC-A)
Ex'd', CONNECTOR PLUG (CR) TO DISTRIBUTION BOARD (HAWKE CAT. REF. Ex'd-
3.2.4 32-N-CR-A-1-95-P-FRC-A)

4.0 WELDING RECEPTACLE


WELDING RECEPTACLE WITH INTERLOCKING SWITCH AND MATCHING PLUG,
440V, 60Hz, 63A, 3PH, 4PIN (3P+PE), IP56, Ex`de', T3, SUITABLE FOR ZONE-1 IIB
HAZARDOUS AREA, WITH 2XM40 CABLE ENTRIES, AND TERMINALS SUITABLE
4.1.1 FOR 3CX50SQMM CABLES, 2 Nos. IP66/67, Ex`d BRASS NICKEL PLATED DOUBLE
COMPRESSION CABLE GLANDS SUITABLE FOR ARMOURED CABLE AND 1 No.
Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUG.

5.0 ELECTRICAL POWER JUNCTION BOX


5.1.1 ELECTRICAL POWER JUNCTION BOX 2

6.0 AERONAUTICAL OBSTRUCTION LIGHT JUNCTION BOX

ELECTRICAL JUNCTION BOX, SS316L, IP 66 Ex`d', T3, SUITABLE FOR ZONE-1 IIB
HAZARDOUS AREA, WITH EXTERNAL BRASS EARTHING STUD AND 1No.(M20)
CABLE ENTRY AND 1No.(M20) IP66/67 Ex'd' BRASS NICKEL PLATED DOUBLE
COMPRESSION CABLE GLANDS SUITABLE FOR 2C x 6sq.mm x LPF/EPR
INSULATED FIRE RESISTANT (MGT) AND ARMOURED CABLE FROM MODULE - 20
EMERGENCY LIGHTING DB AND 1No.(M20) CABLE ENTRY WITH Ex`d' IP66/67
6.1.1 2
BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLAND SUITABLE FOR 2C
X 4sq.mm HEAVY DUTY TYPE COPPER CONDUCTOR / COMPRESSED MINERAL
INSULATION COPPER SHEATH CABLE (TYPE-MI) TO OBSTRUCTION LIGHT (25-LTG-
7852-01/01M/2M) ON FLARE TOWER LEVEL EL.+83150 AND (25-LTG-7852-
01/01N/2N) ON FLARE TOWER LEVEL EL.+118150.

7.0 POWER CABLE


7.1. MINERAL INSULATED POWER CABLE 100
7.1.2 POWER CABLE 50

8.1 AERONAUTICAL OBSTRUCTION LIGHT CABLE 160

Lighting and Small Power Cables


MODULE
ITEM No. DESCRIPTION 25

1.1 NORMAL LIGHTING CABLE


1.1.1 0.6/1kV 2CX2.5 Sq.mm COPPER ARMOURED/BRAIDED CABLE (RFOU) 1030
1.1.2 0.6/1kV 2CX6 Sq.mm COPPER ARMOURED/BRAIDED CABLE (RFOU) 231

1.2 EMERGENCY LIGHTING CABLE


1.2.1 0.6/1kV 2CX2.5 Sq.mm COPPER ARMOURED/BRAIDED CABLE (BFOU) 1100
1.2.2 0.6/1kV 2CX6 Sq.mm COPPER ARMOURED/BRAIDED CABLE (BFOU) 220
1.2.3 0.6/1kV 2CX4 Sq.mm COPPER ARMOURED/BRAIDED CABLE (BFOU)
Total
Materials E&I Intallation

UNIT Unit rates Total rates Unit rate Total Rates

Nos. Free issue -

Nos.

Nos.

M Free issue -
M Free issue -
M Free issue -
M

Nos.

UNIT
Nos

Nos

Nos.

Nos.

Nos.
Nos.

Nos.

Nos.

Nos.
Nos.

Nos.

Nos.

Nos.

Nos.
Nos.

Nos.

Nos.

Nos.

Nos.
Nos.

Nos.

Nos.

Nos.

Nos.
Nos.

Nos.

Nos.

Nos.

Nos.
Nos.

Nos. Free issue -

Nos.

Nos

Nos

Nos

Nos

Nos

Nos

Nos
Nos

Nos

Nos

Nos

Nos

Nos

Nos

Nos

Nos Free issue -

Nos

Nos

Nos Free issue -


Nos Free issue -

Nos Free issue -

Nos

Nos Free issue -

Nos

Nos

Nos

Nos

Nos

Nos
Nos Free issue -

Nos Free issue -

Nos

Nos

Nos

Nos

Nos
Nos

Nos. Free issue -

Nos. Free issue -

M Free issue -
M Free issue -

M Free issue -

UNIT

M Free issue -
M Free issue -

M Free issue -
M Free issue -
M
- -
MODULE 40 - UTILITY MODULE
INSTRUMENTATION
MODULE 40 (P04) UTILITIES

DESCRIPTION

FIELD INSTRUMENTATION ITEMS - FREE-ISSUED BY BAB,


E&I Subcontractor TO CARRY OUT INSPECTION, INSTALLATION, ITR AND MECH
COMPLETION
BLOWDOWN VALVES, PNEUMATIC ACTUATOR, SOLENOID VLV AND LIMIT SW
CONTROL VALVES, PNEUMATIC ACTUATED WITH I/P POSITIONER
PRESSURE RELIEF VALVES, API 526 FLANGED TYPE
SHUTDOWN VALVES, PNEUMATIC ACTUATOR, SOLENOID VLV AND LIMIT SW
ACTUATED VALVES, PNEUMATIC ACTUATED, SOLENOID VLV AND LIMIT SW
ACTUATED VALVES, ELECTRIC MOTOR OPERATED
CHOKE VALVES, STEPPER MOTOR OPERATED

LEVEL TRANSMITTER, GUIDED WAVE RADAR WITH EXTERNAL CHAMBER


LEVEL TRANSMITTER/ GAUGE, MAGNETIC TYPE

FLOWMETER, ELECTROMAGNETIC
FLOWMETER, ORIFICE PLATE AND FLANGE SET
FLOWMETER, ROTAMETER INDICATOR
FLOWMETER, DP FLOW TRANSMITTERS WITH 5-VALVE MANIFOLD
FLOWMETER, ULTRASONIC / CORIOLIS WITH INTEGRAL FLOW TRANSMITTER
FLOWMETER, VENTURI

PRESSURE GAUGES WITH 2-VALVE MANIFOLD


PRESSURE TRANSMITTERS, WITH 2 VALVE MANIFOLD
DP GAUGES WITH 5-VALVE MANIFOLD
DP TRANSMITTERS 5-VALVE MANIFOLD

TEMPERATURE GAUGE
TEMPERATURE TRANSMITTERS

RESTRICTION ORIFICE
RUPTURE DISC
PRESSURE SWITCH
PIG SIGNALLER, NON INTRUSIVE

ANALYZER, LIQUID, BS&W / TURBIDITY / OIL IN WATER


ANALYZER, GAS, MOISTURE

FIRE AND GAS INSTRUMENTATION ITEMS - FREE-ISSUED BY BAB,


E&I Subcontractor TO CARRY OUT INSPECTION, INSTALLATION, ITR AND MECH
COMPLETION
FLAME DETECTOR (TRIPLE IR)
GAS DETECTOR (IR POINT TYPE)
H2S GAS DETECTOR
OPEN PATH GAS DETECTOR (RECEIVER)
OPEN PATH GAS DETECTOR (TRANSMITTER)
MANUAL ALARM CALL POINT
FUSIBLE PLUG PANEL

PAGA / TELECOM ITEMS - FREE-ISSUED BY BAB,


E&I Subcontractor TO CARRY OUT INSPECTION, INSTALLATION, ITR AND MECH
COMPLETION
EX-PROOF PAGA BEACON with TERMINAL BOX
EX-PROOF PAGA SPEAKER with TERMINAL BOX
EX-PROOF PTZ CCTV CAMERA with TERMINAL BOX
EX-PROOF SOUNDER BEACON with TERMINAL BOX
EX-PROOF TELEPHONE

REMOTE I/O ENCLOSURE - FREE-ISSUED BY BAB,


E&I Subcontractor TO CARRY OUT INSPECTION, INSTALLATION, ITR AND MECH
COMPLETION

PCS REMOTE CABINET (800 X 800 X 600mm) Ex'e 316L SS CONTROL PANEL WITH SUNSHADE

JUNCTION BOXES - E&I Subcontractor TO SUPPLY, CARRY OUT INSPECTION, INSTALLATION,


ITR AND MECH COMPLETION

INSTRUMENT JUNCTION BOXES (350 x 260 x 250mm) Ex'e 316L SS


FGS JUNCTION BOXES (350 x 260 x 250mm) Ex'e 316L SS
PAGA JUNCTION BOXES (350 x 260 x 250mm) Ex'e 316L SS

2" INSTRUMENT MOUNTING STAND/BRACKET


3" FIRE/GAS MOUNTING STAND/BRACKET FOR FLAME AND GAS DETECTOR
3" PAGA SPEAKER/BEACON STAND/BRACKET
JUNCTION BOX STAND/ BRACKET
JB AND PANEL SUPPORT ACCESSORIES - FABRICATOR TO ESTIMATE

INSTRUMENT TUBE AND TUBE FITTINGS - E&I Subcontractor TO SUPPLY, CARRY OUT
INSPECTION, INSTALLATION, ITR AND MECH COMPLETION
1/2" OD Tubing- Wall Thickness 0.065 316L SS
1/4" OD Tubing- Wall Thickness 0.049 316L SS
3/8" OD Tubing- Wall Thickness 0.049 316L SS
1/2" OD Tube Union, 316 SS
1/4" OD Tube Union, 316 SS
3/8" OD Tube Union, 316 SS

1/2"OD x 1/2" NPT Male Conn, 316 SS


3/8"OD x 1/2" NPT Male Conn, 316 SS

3/8" Fusible Plugs, 316 SS


3/8" OD Tubing- Wall Thickness 0.049 316L SS for FPL
3/8" Tube Union, 316 SS

TUBING STRUCTURAL SUPPORT - FABRICATOR TO ESTIMATE

INSTRUMENT AIR SUPPPLY ITEMS - E&I Subcontractor TO SUPPLY, CARRY OUT


INSPECTION, INSTALLATION, ITR AND MECH COMPLETION
INSTRUMENT AIR HEADER / SUBHEADER - by piping
INSTRUMENT AIR MANIFOLD (8 way)
1/2" BALL VALVES FOR MANIFOLD
1/2" BALL VALVES FOR FIELD INSTR

AIR MANIFOLD AND TUBING STRUCTURAL SUPPORT - FABRICATOR TO ESTIMATE

CABLE LADDER AND ACCESSORIES - E&I Subcontractor TO SUPPLY, CARRY OUT


INSPECTION, INSTALLATION, ITR AND MECH COMPLETION

STRAIGHT CABLE LADDER WITH COVER : 300MM WIDE


STRAIGHT CABLE LADDER WITH COVER : 450MM WIDE
STRAIGHT CABLE LADDER WITH COVER: 600MM WIDE
HORIZONTAL UNEQUAL TEE : 650MM/450MM/600MM WIDE
HORIZONTAL UNEQUAL TEE : 450MM/300MM/450MM WIDE

STRAIGHT CABLE TRAY WITH COVER : 50MM WIDE


STRAIGHT CABLE TRAY WITH COVER : 100MM WIDE
STRAIGHT CABLE TRAY WITH COVER : 150MM WIDE

CABLE LADDER AND TRAY STRUCTURAL SUPPORT - FABRICATOR TO ESTIMATE


CABLE LADDER AND TRAY ACCESSORIES, EARTHING, ETC, FABRICATOR TO ESTIMATE

INSTRUMENT CABLES - E&I Subcontractor TO SUPPLY, CARRY OUT INSPECTION,


INSTALLATION, ITR AND MECH COMPLETION
(LV Cables 600V/1000V - Instrument Power)
2C X 2.5mm² IEC 60331
4C X 2.5mm² IEC 60331
12C X 2.5mm² IEC 60332
(Instrument & Communication Cables - Individual and Collective Screened cables)
1Pr X 1.5mm² IEC 60332
2Pr X 1.5mm² IEC 60332
5Pr X 1.0mm² IEC 60332
10Pr X 1.0mm² IEC 60332
20Pr X 1.0mm² IEC 60332
(Fire/Gas & Communication Cables - Individual and Collective Screened cables)
1Tr X 1.5mm² IEC 60331
1Pr X 1.5mm² IEC 60331
(Earthing Materials - Instrumentation)
EARTH CABLE - 6 SQ.MM
EARTH CABLE - 25 SQ.MM
EARTH BOSS ; M10 X 40MM DIA X 35MM LG. CW/ ACCESSORIES
(Glanding & Termination - Instrumentation)
1Pr X 1.5mm²
2Pr X 1.5mm²
5Pr X 1.0mm²
10Pr X 1.0mm²
20Pr X 1.0mm²
1Pr X 1.5mm²
1Tr X 1.5mm²
2C X 2.5mm²
4C X 2.5mm²
12C X 2.5mm²

ELECTRICAL
Cable Ladder & Accessories

ITEM NO DESCRIPTION

1.0 EARTHING ACCESSORIES


1.1 EARTH BOSS
50MM DIA -STAINLESS STEEL EARTHING BOSS C/W M10 STAINLESS STEEL STUD, WASHER
1.1.1 AND NUTS.
40MM DIA -STAINLESS STEEL EARTHING BOSS C/W M10 STAINLESS STEEL STUD, WASHER
1.1.2 AND NUTS.

EARTH BAR
1.2 50X6MM TINNED PLATED EARTH BAR (300mm TO 450mm LONG)

1.3 EARTHING CABLES


STRANDED COPPER CONDUCTOR, LOW SMOKE ZERO HALOGEN THERMOSET COMPOUND
INSULATED,INCLUSIVE OF NECESSARY COMPRESSION TYPE COPPER LUGS COMPLETE
WITH SS316L BOLTS, NUTS, FLAT WASHERS AND SPRING WASHERS.

COLOUR: GREEN WITH YELLOW STRIPE.


1.3.1 1C X 6MM²
1.3.2 1C X 25MM²
1.3.3 1C X 70MM²
1.3.4 1C X 120MM²

1.3.5 1C X 70mm² EARTHING CABLE FOR PRE-COMMISSIONING/COMMISSIONING EQUIPMENT.

1.3.6 SS136L CROCODILE CLIP SUITABLE FOR 70mm² EARTHING CABLE

Earthing accessories

ITEM NO DESCRIPTION

1.0 EARTHING ACCESSORIES


1.1 EARTH BOSS
50MM DIA -STAINLESS STEEL EARTHING BOSS C/W M10 STAINLESS STEEL STUD, WASHER
1.1.1 AND NUTS.
40MM DIA -STAINLESS STEEL EARTHING BOSS C/W M10 STAINLESS STEEL STUD, WASHER
1.1.2 AND NUTS.

EARTH BAR
1.2 50X6MM TINNED PLATED EARTH BAR (300mm TO 450mm LONG)

1.3 EARTHING CABLES

STRANDED COPPER CONDUCTOR, LOW SMOKE ZERO HALOGEN THERMOSET COMPOUND


INSULATED,INCLUSIVE OF NECESSARY COMPRESSION TYPE COPPER LUGS COMPLETE
WITH SS316L BOLTS, NUTS, FLAT WASHERS AND SPRING WASHERS.

COLOUR: GREEN WITH YELLOW STRIPE.


1.3.1 1C X 6MM²
1.3.2 1C X 25MM²
1.3.3 1C X 70MM²
1.3.4 1C X 120MM²

1.3.5 1C X 70mm² EARTHING CABLE FOR PRE-COMMISSIONING/COMMISSIONING EQUIPMENT.

1.3.6 SS136L CROCODILE CLIP SUITABLE FOR 70mm² EARTHING CABLE

Lighting Fixtures & Small Power receptacles, Welding Sockets

ITEM No. DESCRIPTION

1.0 DISTRIBUTION BOARDS AND ACCESSORIES


1.1 LIGHTING DISTRIBUTION BOARD
NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 63A,MINMUM(IP56), Ex'd',
T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION HEATER ,
1No.63A, 3P, MCCB FOR INCOMING CABLE, 18Nos.16A, 2P MCBs FOR OUTGOING,
1.1.1 18Nos. (M20) + 1 No. (M50) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION
CABLE GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED
CABLE (RFOU) AND 4 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUGS.

NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 63A,MINMUM(IP56), Ex'd',


T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION HEATER ,
1No.63A, 3P, MCCB FOR INCOMING CABLE, 18Nos.16A, 2P MCBs FOR OUTGOING,
1.1.2 18Nos. (M20) + 1 No. (M32) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION
CABLE GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED
CABLE (RFOU) AND 6 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUGS.

NORMAL LIGHTING AND SMALL POWER DISTRIBUTION BOARD, 230V, 3PH, 60Hz,
100A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH
ANTI-CONDENSATION HEATER ,1No.100A, 3P, MCCB FOR INCOMING CABLE, 2Nos.40A, 1
1.1.3 No. 32A,1 No. 25A and 11 Nos. 16A 2P MCBs FOR OUTGOING, 15Nos. (M20) + 1 No.
(M32) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE
(RFOU) AND 7 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUGS.

NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 63A,MINMUM(IP56), Ex'd',


T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION HEATER ,
1No.63A, 3P, MCCB FOR INCOMING CABLE, 15Nos.16A, 2P MCBs FOR OUTGOING,
1.1.4 15Nos. (M20) + 1 No. (M40) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION
CABLE GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED
CABLE (RFOU) AND 6 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUGS.

NORMAL POWER DISTRIBUTION BOARD, 440V, 3PH, 60Hz, 250A,MINMUM(IP56), Ex'd',


T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION HEATER ,
1No.100A, 3P, MCCB FOR INCOMING CABLE, 5 Nos.100A MCCBs FOR OUTGOING, 5Nos.
1.1.5 (M63) + 1 No. (GLAND SUITABLE FOR 3RX1CX120 sq.mm CABLES) Ex'de' IP66/67 BRASS
NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS(MAKE :HAWKE 501/453/UNIV)
SUITABLE FOR ARMOURED/BRAIDED CABLE (RFOU) AND 4 Nos. (M63) Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUGS.

NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 63A,MINMUM(IP56), Ex'd',


T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION HEATER ,
1No.63A, 3P, MCCB FOR INCOMING CABLE, 18Nos.16A, 2P MCBs FOR OUTGOING,
1.1.6 18Nos. (M20) + 1 No. (M50) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION
CABLE GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED
CABLE (RFOU) AND 3 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUGS.
NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 63A,MINMUM(IP56), Ex'd',
T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION HEATER ,
1No.63A, 3P, MCCB FOR INCOMING CABLE, 12Nos.16A, 2P MCBs FOR OUTGOING,
1.1.7 12Nos. (M20) + 1 No. (M40) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION
CABLE GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED
CABLE (RFOU) AND 5 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUGS.

NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 63A,MINMUM(IP56), Ex'd',


T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION HEATER ,
1No.63A, 3P, MCCB FOR INCOMING CABLE, 21Nos.16A, 2P MCBs FOR OUTGOING, 21
1.1.8 Nos. (M20) + 1 No. (M40) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION
CABLE GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED
CABLE (RFOU) AND 6 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUGS.

NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 63A,MINMUM(IP56), Ex'd',


T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION HEATER ,
1No.63A, 3P, MCCB FOR INCOMING CABLE, 12Nos.16A, 2P MCBs FOR OUTGOING, 12
1.1.9 Nos. (M20) + 1 No. (M32) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION
CABLE GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED
CABLE (RFOU) AND 5 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUGS.

NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 63A,MINMUM(IP56), Ex'd',


T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION HEATER ,
1No.63A, 3P, MCCB FOR INCOMING CABLE, 21 Nos.16A, 2P MCBs FOR OUTGOING, 21
1.1.10 Nos. (M20) + 1 No. (M50) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION
CABLE GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED
CABLE (RFOU) AND 3 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUGS.

NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 63A,MINMUM(IP56), Ex'd',


T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION HEATER ,
1No.63A, 3P, MCCB FOR INCOMING CABLE, 12 Nos.16A, 2P MCBs FOR OUTGOING, 12
1.1.11 Nos. (M20) + 1 No. (M50) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION
CABLE GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED
CABLE (RFOU) AND 3 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUGS.

NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 63A,MINMUM(IP56), Ex'd',


T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION HEATER ,
1No.63A, 3P, MCCB FOR INCOMING CABLE, 21 Nos.16A, 2P MCBs FOR OUTGOING, 21
1.1.12 Nos. (M20) + 1 No. (M32) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION
CABLE GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED
CABLE (RFOU) AND 5 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUGS.
NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 63A,MINMUM(IP56), Ex'd',
T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION HEATER ,
1No.63A, 3P, MCCB FOR INCOMING CABLE, 21 Nos.16A, 2P MCBs FOR OUTGOING, 21
1.1.13 Nos. (M20) + 1 No. (M50) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION
CABLE GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED
CABLE (RFOU) AND 5 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUGS.

NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 63A,MINMUM(IP56), Ex'd',


T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION HEATER ,
1No.63A, 3P, MCCB FOR INCOMING CABLE, 18 Nos.16A, 2P MCBs FOR OUTGOING, 18
1.1.14 Nos. (M20) + 1 No. (M50) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION
CABLE GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED
CABLE (RFOU) AND 6 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 63A,MINIMUM(IP56),


Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION
HEATER,1No.63A, 3P, MCCB FOR INCOMING CABLE, 12Nos.16A, 2P MCBs FOR
1.1.15 OUTGOING, 12Nos. (M20) + 1 No. (M40) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE
COMPRESSION CABLE GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (BFOU) AND 8 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL
PLATED BLOCKING PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 63A,MINIMUM(IP56),


Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION
HEATER,1No.63A, 3P, MCCB FOR INCOMING CABLE, 15Nos.16A, 2P MCBs FOR
1.1.16 OUTGOING, 15Nos. (M20) + 1 No. (M32) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE
COMPRESSION CABLE GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (BFOU) AND 3 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL
PLATED BLOCKING PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 63A,MINIMUM(IP56),


Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION
HEATER,1No.63A, 3P, MCCB FOR INCOMING CABLE, 18Nos.16A, 2P MCBs FOR
1.1.17 OUTGOING, 18Nos. (M20) + 1 No. (M40) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE
COMPRESSION CABLE GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (BFOU) AND 4 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL
PLATED BLOCKING PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 63A,MINIMUM(IP56),


Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION
HEATER,1No.63A, 3P, MCCB FOR INCOMING CABLE, 12Nos.16A, 2P MCBs FOR
1.1.18 OUTGOING, 12Nos. (M20) + 1 No. (M40) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE
COMPRESSION CABLE GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (BFOU) AND 6 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL
PLATED BLOCKING PLUGS.
EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 63A,MINIMUM(IP56),
Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION
HEATER,1No.63A, 3P, MCCB FOR INCOMING CABLE, 9Nos.16A, 2P MCBs FOR OUTGOING,
1.1.19 9 Nos. (M20) + 1 No. (M40) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION
CABLE GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED
CABLE (BFOU) AND 5 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 63A,MINIMUM(IP56),


Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION
HEATER,1No.63A, 3P, MCCB FOR INCOMING CABLE, 24 Nos.16A, 2P MCBs FOR
1.1.20 OUTGOING, 24 Nos. (M20) + 1 No. (M40) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE
COMPRESSION CABLE GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (BFOU) AND 3 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL
PLATED BLOCKING PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 63A,MINIMUM(IP56),


Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION
HEATER,1No.63A, 3P, MCCB FOR INCOMING CABLE, 18 Nos.16A, 2P MCBs FOR
1.1.21 OUTGOING, 18 Nos. (M20) + 1 No. (M50) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE
COMPRESSION CABLE GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (BFOU) AND 4 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL
PLATED BLOCKING PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 63A,MINIMUM(IP56),


Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION
HEATER,1No.63A, 3P, MCCB FOR INCOMING CABLE, 18 Nos.16A, 2P MCBs FOR
1.1.22 OUTGOING, 18 Nos. (M20) + 1 No. (M50) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE
COMPRESSION CABLE GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (BFOU) AND 3 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL
PLATED BLOCKING PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 63A,MINIMUM(IP56),


Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION
HEATER,1No.63A, 3P, MCCB FOR INCOMING CABLE, 9Nos.16A, 2P MCBs FOR OUTGOING,
1.1.23 9 Nos. (M20) + 1 No. (M32) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION
CABLE GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED
CABLE (BFOU) AND 5 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 63A,MINIMUM(IP56),


Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION
HEATER,1No.63A, 3P, MCCB FOR INCOMING CABLE, 18Nos.16A, 2P MCBs FOR
1.1.24 OUTGOING, 18 Nos. (M20) + 1 No. (M32) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE
COMPRESSION CABLE GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (BFOU) AND 5 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL
PLATED BLOCKING PLUGS.
EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 63A,MINIMUM(IP56),
Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION
HEATER,1No.63A, 3P, MCCB FOR INCOMING CABLE, 15 Nos.16A, 2P MCBs FOR
1.1.25 OUTGOING, 15 Nos. (M20) + 1 No. (M40) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE
COMPRESSION CABLE GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (BFOU) AND 3 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL
PLATED BLOCKING PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 63A,MINIMUM(IP56),


Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION
HEATER,1No.63A, 3P, MCCB FOR INCOMING CABLE, 15 Nos.16A, 2P MCBs FOR
1.1.26 OUTGOING, 15 Nos. (M20) + 1 No. (M32) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE
COMPRESSION CABLE GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (BFOU) AND 4 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL
PLATED BLOCKING PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 63A,MINIMUM(IP56),


Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION
HEATER,1No.63A, 3P, MCCB FOR INCOMING CABLE, 18Nos.16A, 2P MCBs FOR
1.1.27 OUTGOING, 18 Nos. (M20) + 1 No. (M50) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE
COMPRESSION CABLE GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (BFOU) AND 6 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL
PLATED BLOCKING PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 63A,MINIMUM(IP56),


Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION
HEATER,1No.63A, 3P, MCCB FOR INCOMING CABLE, 21Nos.16A, 2P MCBs FOR
1.1.28 OUTGOING, 21 Nos. (M20) + 1 No. (M40) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE
COMPRESSION CABLE GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (BFOU) AND 4 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL
PLATED BLOCKING PLUGS.

UPS DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 100A,MINIMUM(IP56), Ex'd', T3, SUITABLE
FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION HEATER,1No.100A, 3P,
MCCB FOR INCOMING CABLE, 6 Nos.16A,9 Nos. 10A, 2P MCBs FOR OUTGOING, 15 Nos.
1.1.29 (M20) + 1 No. (M32) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE
(RFOU) AND 7 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUGS.

ESSENTIAL DISTRIBUTION BOARD, 440V, 3PH, 60Hz, 250A,MINMUM(IP56), Ex'd', T3,


SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-CONDENSATION HEATER ,
1No.100A, 3P, MCCB FOR INCOMING CABLE, 5 Nos.100A MCCBs FOR OUTGOING, 5Nos.
1.1.30 (M63) + 1 No. (GLAND SUITABLE FOR 3RX1CX120 sq.mm CABLES) Ex'de' IP66/67 BRASS
NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS(MAKE :HAWKE 501/453/UNIV)
SUITABLE FOR ARMOURED/BRAIDED CABLE (RFOU) AND 4 Nos. (M63) Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUGS.

1.2 LIGHTING JUNCTION BOX


LIGHTING JUCTION BOX INCREASED SAFETY Ex'e' IIB T3,IP56 WITH 3 Nos.(M20) CABLE
ENTRIES, 3 Nos. (M20) Ex'de' IP66/67 BRASS NICKEL PLATED CABLE GLAND (MAKE
1.2.1 :HAWKE 501/453/UNIV) SUITABLE FOR TERMINATION OF 2C X 2.5/6 Sq.mm ARMOURED
CABLE (TYPE -RFOU /BFOU) AND 1No. (M20) Ex'd' IP66/67 BRASS NICKEL PLATED
BLOCKING PLUG.

LIGHTING JUCTION BOX INCREASED SAFETY Ex'e' IIB T3,IP56 WITH 4 Nos.(M20) CABLE
ENTRIES, 4 Nos. (M20) IP66/67 BRASS NICKEL PLATED CABLE GLAND SUITABLE FOR
1.2.2 TERMINATION OF 3C X 2.5/6 Sq.mm ARMOURED CABLE (TYPE - LV1 / LV2) AND 1No.
(M20) IP66/67 BRASS NICKEL PLATED BLOCKING PLUG.

2.0 LIGHT FIXTURES AND ACCESSORIES


2.1 FLUORESCENT LIGHT FIXTURES(2X36W)

FLUORESCENT LIGHT FIXTURE IP66/67, Ex 'e', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS
AREA, WITH 2x36W FLOURESCENT LAMP(TL-D 36W/840 OF PHILIPS) 230V, 1PH(LINE TO
LINE), 60Hz, INTEGRAL CONTROL GEAR BOX, 2xM20 CABLE ENTRY AND 2 Nos. (M20)
EX'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS(MAKE
:HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE (RFOU/BFOU ) AND
1 No. (M20)Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUG. (CHALMIT CAT.
REFERENCE: PRGE/236/BI) OR APPROVED EQUIVALENT

BRACKET MOUNTED - MOUNTING BRACKET AND ACCESSORIES (NORMAL POWER


2.1.1 SUPPLY)
2.1.2 SUSPENSION MOUNTED - MOUNTING ACCESSORIES (NORMAL POWER SUPPLY)
DOUBLE POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (NORMAL POWER
2.1.3 SUPPLY)
SINGLE POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (NORMAL POWER
2.1.4 SUPPLY)
2.1.5 HANDRAIL MOUNTED - ACCESSORIES (NORMAL POWER SUPPLY)

2.1.6 BRACKET MOUNTED - MOUNTING BRACKET AND ACCESSORIES (UPS POWER SUPPLY)

2.1.7 SUSPENSION MOUNTED - MOUNTING ACCESSORIES (UPS POWER SUPPLY)


DOUBLE POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (NORMAL POWER
2.1.8 SUPPLY)

2.1.9 SINGLE POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (UPS POWER SUPPLY)

2.1.10 HANDRAIL MOUNTED - ACCESSORIES (UPS POWER SUPPLY)

2.2 FLUORESCENT LIGHT FIXTURES(2X18W)

FLUORESCENT LIGHT FIXTURE IP66/67, Ex 'e', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS
AREA, WITH 2x18W FLOURESCENT LAMP(TL-D 18W/840 OF PHILIPS) 230V, 1PH(LINE TO
LINE), 60Hz, INTEGRAL CONTROL GEAR BOX, 2xM20 CABLE ENTRY AND 2 Nos. (M20)
EX'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS(MAKE
:HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE (RFOU/BFOU ) AND
1 No. (M20)Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUG. (CHALMIT CAT.
REFERENCE: PRGE/218/BI) OR APPROVED EQUIVALENT

2.2.1 HANDRAIL MOUNTED - MOUNTING ACCESSORIES (NORMAL POWER SUPPLY)


2.2.2 HANDRAIL MOUNTED - MOUNTING ACCESSORIES (UPS POWER SUPPLY)
2.2.3 SUSPENSION MOUNTED - MOUNTING ACCESSORIES (UPS POWER SUPPLY)

2.3 FLOOD LIGHT FIXTURES - 400W (WIDE BEAM)

FLOOD LIGHT FIXTURE - ASYMMETRICAL TYPE IP66/67, Ex 'de', T3, SUITABLE FOR ZONE-1
IIB HAZARDOUS AREA, WITH 400W METAL HALIDE LAMP - 230V, 1PH(LINE TO LINE), 60Hz,
INTEGRAL CONTROL GEAR BOX, 2xM20 CABLE ENTRY AND 2 Nos. (M20) Ex'de' BRASS
NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS (MAKE :HAWKE 501/453/UNIV)
SUITABLE FOR ARMOURED/BRAIDEDCABLE (TYPE - RFOU / BFOU) AND 1 No. (M20) Ex`d'
IP66/67 BRASS NICKEL PLATED BLOCKING PLUG. (CHALMIT CAT. REFERENCE:
EV2D/400/MS/60) OR APPROVED EQUIVALENT

2.3.1 POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (NORMAL POWER SUPPLY)
2.3.2 POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (UPS POWER SUPPLY)
2.3.3 BRACKET MOUNTED - MOUNTING BRACKET AND ACCESSORIES (UPS POWER SUPPLY)

2.4 LED FLOOD LIGHT FIXTURE (34W)-WIDE BEAM

FLOOD LIGHT FIXTURE WITH WIDE BEAM IP66/67, Ex 'de', T3, SUITABLE FOR ZONE-1 IIB
HAZARDOUS AREA, WITH 34W HIGH POWER LIGHT EMITTING DIODES(LEDs) - 230V,
1PH(LINE TO LINE), 60Hz, INTEGRAL CONTROL GEAR BOX,2xM20 CABLE ENTRY AND 2
Nos. (M20) EX'de' BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS
(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE
(RFOU/BFOU) AND 1 No.(M20) Ex'd' IP66/67 BRASS NICKEL PLATED BLOCKING PLUG.
(CHALMIT CAT. REFERENCE: SOLD/034/LE) OR APPROVED EQUIVALENT

2.4.1 BRACKET MOUNTED - MOUNTING BRACKET AND ACCESSORIES (NORMAL POWER SUPPLY)
2.4.2 POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (NORMAL POWER SUPPLY)
2.4.3 BRACKET MOUNTED - MOUNTING BRACKET AND ACCESSORIES (UPS POWER SUPPLY)
2.4.4 POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (UPS POWER SUPPLY)

2.5 LED FLOOD LIGHT FIXTURE (125W)-WIDE BEAM

FLOOD LIGHT FIXTURE WITH WIDE BEAM IP66/67, Ex 'de', T3, SUITABLE FOR ZONE-1 IIB
HAZARDOUS AREA, WITH 125W HIGH POWER LIGHT EMITTING DIODES(LEDs) - 230V,
1PH(LINE TO LINE), 60Hz, INTEGRAL CONTROL GEAR BOX,2xM20 CABLE ENTRY AND 2
Nos. (M20) EX'de' BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS
(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE
(RFOU/BFOU) AND 1 No.(M20) Ex'd' IP66/67 BRASS NICKEL PLATED BLOCKING PLUG.
(CHALMIT CAT. REFERENCE: SOLD/12L/LE) OR APPROVED EQUIVALENT

2.5.1 BRACKET MOUNTED - MOUNTING BRACKET AND ACCESSORIES (NORMAL POWER SUPPLY)
2.5.2 POLE MOUNTED - MOUNTING POLE ACCESSORIES (NORMAL POWER SUPPLY)
2.5.3 BRACKET MOUNTED - MOUNTING BRACKET AND ACCESSORIES (UPS POWER SUPPLY)
2.5.4 POLE MOUNTED - MOUNTING POLE ACCESSORIES (UPS POWER SUPPLY)

2.6 AERONAUTICAL OBSTRUCTION LIGHT


MEDIUM INTENSITY, ICAO TYPE C (STEADY BURNING, RED COLOUR) AERONAUTICAL
OBSTRUCTION LIGHT COVERED WITH HEAT SHIELD Ex`d' IIC T6, IP66 SUITABLE FOR ZONE-
1 IIB HAZARDOUS AREA, WITH 35W LED LIGHT 230V, 1PH, 60Hz, INTEGRAL CONTROL
GEAR BOX, 2xM20 CABLE ENTRY AND 2 Nos. (M20) Ex`d' BRASS NICKEL PLATED DOUBLE
2.6.1 COMPRESSION CABLE GLANDS SUITABLE FOR 2C X 4sq.mm HEAVY DUTY TYPE COPPER
CONDUCTOR / COMPRESSED MINERAL INSULATION COPPER SHEATH CABLE (TYPE-MI)
WITH BLOCKING PLUG. (CLAMP CATALOGUE REFERENCE : SEGS23C2K (MEDIUM
INTENSITY TYPE) OR APPROVED EQUIVALENT.

2.7 HEAT SHIELD FOR OBSTRUCTION LIGHT:


HEAT SHIELD (POINT LIGHTING CATALOGUE REF : PL40139-SS) OR APPROVED
EQUIVALENT.
2.7.1

3.0 SOCKET OUTLETS & PLUGS


3.1 16A OUTDOOR POWER SOCKET

POWER SOCKET WITH INTERLOCKING SWITCH AND MATCHING PLUG, 230V, 16A,
1PH(LINE TO LINE),3PIN(2P+E), IP56, Ex`de', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS
AREA. POWER SOCKET: WITH 2xM20 CABLE ENTRIES, 1 No.M20 IP66/67, Ex`de' BRASS
3.1.1 NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS (MAKE :HAWKE 501/453/UNIV)
SUITABLE FOR ARMOURED/BRAIDED CABLE AND 1 No.M20 Ex`d' IP66/67 BRASS NICKEL
PLATED BLOCKING PLUG. POWER PLUG: WITH Ex'd' IP66/67 CABLE GLAND ENTRY
SUTABLE FOR 2Cx6 SQMM EPR/XLPE INSULATED AND BRAIDED FLEXIBLE CABLE .

3.2 LVSR CONNECTORS & RECEPTACLES FOR PIGTAIL CONNECTIONS


CONNECTOR PLUG (CP) WITH CAP
Ex'd', CONNECTOR PLUG (CP) FROM LVSR (HAWKE CAT. REF. Ex'd-32-N-CP-B-1-120-S-FPC-
3.2.1 A)

3.2.2 Ex'd', CONNECTOR PLUG (CP) FROM LVSR (HAWKE CAT. REF. Ex'd-32-N-CP-B-1-95-S-FPC-A)

CONNECTOR RECEPTACLES (CR) WITH CAP


Ex'd', CONNECTOR PLUG (CR) TO DISTRIBUTION BOARD (HAWKE CAT. REF. Ex'd-32-N-CR-
3.2.3 B-1-120-P-FRC-A)
Ex'd', CONNECTOR PLUG (CR) TO DISTRIBUTION BOARD (HAWKE CAT. REF. Ex'd-32-N-CR-
3.2.4 A-1-95-P-FRC-A)

4.0 WELDING RECEPTACLE

WELDING RECEPTACLE WITH INTERLOCKING SWITCH AND MATCHING PLUG, 440V, 60Hz,
63A, 3PH, 4PIN (3P+PE), IP56, Ex`de', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH 2XM40 CABLE ENTRIES, AND TERMINALS SUITABLE FOR 3CX50SQMM CABLES, 2
4.1.1 Nos. IP66/67, Ex`d BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS
SUITABLE FOR ARMOURED CABLE AND 1 No. Ex`d' IP66/67 BRASS NICKEL PLATED
BLOCKING PLUG.
5.0 ELECTRICAL POWER JUNCTION BOX
5.1.1 ELECTRICAL POWER JUNCTION BOX

6.0 AERONAUTICAL OBSTRUCTION LIGHT JUNCTION BOX

ELECTRICAL JUNCTION BOX, SS316L, IP 66 Ex`d', T3, SUITABLE FOR ZONE-1 IIB
HAZARDOUS AREA, WITH EXTERNAL BRASS EARTHING STUD AND 1No.(M20) CABLE
ENTRY AND 1No.(M20) IP66/67 Ex'd' BRASS NICKEL PLATED DOUBLE COMPRESSION
CABLE GLANDS SUITABLE FOR 2C x 6sq.mm x LPF/EPR INSULATED FIRE RESISTANT (MGT)
AND ARMOURED CABLE FROM MODULE - 20 EMERGENCY LIGHTING DB AND 1No.(M20)
6.1.1 CABLE ENTRY WITH Ex`d' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLAND SUITABLE FOR 2C X 4sq.mm HEAVY DUTY TYPE COPPER CONDUCTOR /
COMPRESSED MINERAL INSULATION COPPER SHEATH CABLE (TYPE-MI) TO OBSTRUCTION
LIGHT (25-LTG-7852-01/01M/2M) ON FLARE TOWER LEVEL EL.+83150 AND (25-LTG-7852-
01/01N/2N) ON FLARE TOWER LEVEL EL.+118150.

7.0 POWER CABLE


7.1. MINERAL INSULATED POWER CABLE
7.1.2 POWER CABLE

8.1 AERONAUTICAL OBSTRUCTION LIGHT CABLE

Lighting and Small Power Cables

ITEM No. DESCRIPTION

1.1 NORMAL LIGHTING CABLE


1.1.1 0.6/1kV 2CX2.5 Sq.mm COPPER ARMOURED/BRAIDED CABLE (RFOU)
1.1.2 0.6/1kV 2CX6 Sq.mm COPPER ARMOURED/BRAIDED CABLE (RFOU)

1.2 EMERGENCY LIGHTING CABLE


1.2.1 0.6/1kV 2CX2.5 Sq.mm COPPER ARMOURED/BRAIDED CABLE (BFOU)
1.2.2 0.6/1kV 2CX6 Sq.mm COPPER ARMOURED/BRAIDED CABLE (BFOU)
1.2.3 0.6/1kV 2CX4 Sq.mm COPPER ARMOURED/BRAIDED CABLE (BFOU)

Total
Materials E&I Intallation
UNIT UOM Unit rates Total rates Unit rate Total Rates

Nos.
13 Nos. Free issue -
18 Nos. Free issue -
Nos.
3 Nos. Free issue -
Nos.
Nos.

Nos.
3 Nos. Free issue -

1 Nos. Free issue -


7 Nos. Free issue -
3 Nos. Free issue -
10 Nos. Free issue -
Nos.
Nos.

31 Nos. Free issue -


24 Nos. Free issue -
1 Nos. Free issue -
7 Nos. Free issue -

22 Nos. Free issue -


14 Nos. Free issue -

1 Nos. Free issue -


Nos.
Nos.
Nos.

Nos.
Nos.
8 Nos. Free issue -
9 Nos. Free issue -
Nos.
2 Nos. Free issue -
2 Nos. Free issue -
3 Nos. Free issue -
Nos.

3 Nos. Free issue -


8 Nos. Free issue -
1 Nos. Free issue -
1 Nos. Free issue -
1 Nos. Free issue -

1 Nos. Free issue -

6 Nos. - -
3 Nos. - -
1 Nos. - -

45 Nos. - -
21 Nos. - -
12 Nos. - -
11 Nos. - -

360 metre - -
27 Nos. - -
96 Nos. - -
60 Nos. - -
9 Nos. - -
16 Nos. - -

120 Nos. - -
32 Nos. - -

Nos.
metre
Nos.

4 Nos. - -
32 Nos. - -
14 Nos. - -

60 Mtr - -
100 Mtr - -
100 Mtr - -
4 nos - -
4 nos - -

240 Mtr - -
120 Mtr - -
60 Mtr - -

75 Mtr - -
0 Mtr
0 Mtr
1800 Mtr - -
75 Mtr - -
Mtr
360 Mtr - -
120 Mtr - -

600 Mtr - -
500 Mtr - -

76 Mtr - -
178 Mtr - -
89 Nos. - -

144 Nos. - -
6 Nos. - -
0 Nos.
24 Nos. - -
8 Nos. - -
475 Mtr - -
48 Nos. - -
40 Nos. - -
0 Mtr
0 Mtr

MODULE 40 UNIT

211 Nos. Free issue


-
Nos.

Nos.
212 M Free issue -
139 M Free issue -
78 M Free issue -
M

Nos.

MODULE 40 UNIT

211 Nos. Free issue


-
Nos.

Nos.

212 M Free issue -


139 M Free issue -
78 M Free issue -
M

Nos.

MODULE 40 UNIT
Nos

Nos

Nos.

Nos.

Nos.

Nos.
Nos.

Nos.

Nos.

Nos.

1 Nos.

Nos.
Nos.

Nos.

Nos.

Nos.

Nos.

Nos.
Nos.

Nos.

Nos.

Nos.

Nos.

Nos.
1 Nos.

Nos.

Nos.

Nos.

Nos.

Nos.
6 Nos. Free issue

1 Nos. Free issue

26 Nos Free issue

-
1 Nos Free issue
-
9 Nos Free issue -
Nos

Nos

Nos

Nos

9 Nos Free issue -


Nos

7 Nos Free issue


-
Nos

5 Nos Free issue

-
3 Nos Free issue -
1 Nos Free issue -
1 Nos Free issue -

Nos

Nos
Nos
Nos

4 Nos Free issue

-
1 Nos Free issue -
Nos
3 Nos Free issue -
Nos

9 Nos Free issue

-
4 Nos Free issue -
2 Nos Free issue -
3 Nos Free issue -
Nos
Nos

Nos

1 Nos Free issue

Nos

Nos

Nos

Nos

1 Nos Free issue

-
Nos.

Nos.

M
M

MODULE 40 UNIT

1030 M Free issue -


231 M Free issue -

1100 M Free issue -


220 M Free issue -
M

- -
MODULE 50 - CHEMICAL INJECTION MODULE

INSTRUMENTATION
Lighting and Small Power Cables

ITEM No.
ITEM No.

1.1
1.1.1
1.1.2

1.2
1.2.1
1.2.2
1.2.3
MODULE 50 - CHEMICAL INJECTION MODULE

INSTRUMENTATION
MODULE 50 (S04) CHEMICAL INJECTION

DESCRIPTION

FIELD INSTRUMENTATION ITEMS - FREE-ISSUED BY BAB,


E&I Subcontractor TO CARRY OUT INSPECTION, INSTALLATION, ITR AND MECH COMPLETION
BLOWDOWN VALVES, PNEUMATIC ACTUATOR, SOLENOID VLV AND LIMIT SW
CONTROL VALVES, PNEUMATIC ACTUATED WITH I/P POSITIONER
PRESSURE RELIEF VALVES, API 526 FLANGED TYPE
SHUTDOWN VALVES, PNEUMATIC ACTUATOR, SOLENOID VLV AND LIMIT SW
ACTUATED VALVES, PNEUMATIC ACTUATED, SOLENOID VLV AND LIMIT SW
ACTUATED VALVES, ELECTRIC MOTOR OPERATED
CHOKE VALVES, STEPPER MOTOR OPERATED

LEVEL TRANSMITTER, GUIDED WAVE RADAR WITH EXTERNAL CHAMBER


LEVEL TRANSMITTER/ GAUGE, MAGNETIC TYPE

FLOWMETER, ELECTROMAGNETIC
FLOWMETER, ORIFICE PLATE AND FLANGE SET
FLOWMETER, ROTAMETER INDICATOR
FLOWMETER, DP FLOW TRANSMITTERS WITH 5-VALVE MANIFOLD
FLOWMETER, ULTRASONIC / CORIOLIS WITH INTEGRAL FLOW TRANSMITTER
FLOWMETER, VENTURI

PRESSURE GAUGES WITH 2-VALVE MANIFOLD


PRESSURE TRANSMITTERS, WITH 2 VALVE MANIFOLD
DP GAUGES WITH 5-VALVE MANIFOLD
DP TRANSMITTERS 5-VALVE MANIFOLD

TEMPERATURE GAUGE
TEMPERATURE TRANSMITTERS

RESTRICTION ORIFICE
RUPTURE DISC
PRESSURE SWITCH
PIG SIGNALLER, NON INTRUSIVE

ANALYZER, LIQUID, BS&W / TURBIDITY / OIL IN WATER


ANALYZER, GAS, MOISTURE
FIRE AND GAS INSTRUMENTATION ITEMS - FREE-ISSUED BY BAB,
E&I Subcontractor TO CARRY OUT INSPECTION, INSTALLATION, ITR AND MECH COMPLETION
FLAME DETECTOR (TRIPLE IR)
GAS DETECTOR (IR POINT TYPE)
H2S GAS DETECTOR
OPEN PATH GAS DETECTOR (RECEIVER)
OPEN PATH GAS DETECTOR (TRANSMITTER)
MANUAL ALARM CALL POINT
FUSIBLE PLUG PANEL

PAGA / TELECOM ITEMS - FREE-ISSUED BY BAB,


E&I Subcontractor TO CARRY OUT INSPECTION, INSTALLATION, ITR AND MECH COMPLETION
EX-PROOF PAGA BEACON with TERMINAL BOX
EX-PROOF PAGA SPEAKER with TERMINAL BOX
EX-PROOF PTZ CCTV CAMERA with TERMINAL BOX
EX-PROOF SOUNDER BEACON with TERMINAL BOX
EX-PROOF TELEPHONE

REMOTE I/O ENCLOSURE - FREE-ISSUED BY BAB,


E&I Subcontractor TO CARRY OUT INSPECTION, INSTALLATION, ITR AND MECH COMPLETION

PCS REMOTE CABINET (800 X 800 X 600mm) Ex'e 316L SS CONTROL PANEL WITH SUNSHADE

JUNCTION BOXES - E&I Subcontractor TO SUPPLY, CARRY OUT INSPECTION, INSTALLATION, ITR AND MECH COMPLETION

INSTRUMENT JUNCTION BOXES (350 x 260 x 250mm) Ex'e 316L SS


FGS JUNCTION BOXES (350 x 260 x 250mm) Ex'e 316L SS
PAGA JUNCTION BOXES (350 x 260 x 250mm) Ex'e 316L SS

2" INSTRUMENT MOUNTING STAND/BRACKET


3" FIRE/GAS MOUNTING STAND/BRACKET FOR FLAME AND GAS DETECTOR
3" PAGA SPEAKER/BEACON STAND/BRACKET
JUNCTION BOX STAND/ BRACKET
JB AND PANEL SUPPORT ACCESSORIES - FABRICATOR TO ESTIMATE
INSTRUMENT TUBE AND TUBE FITTINGS -E&I Subcontractor TO SUPPLY, CARRY OUT INSPECTION, INSTALLATION, ITR AND ME
COMPLETION
1/2" OD Tubing- Wall Thickness 0.065 316L SS
1/4" OD Tubing- Wall Thickness 0.049 316L SS
3/8" OD Tubing- Wall Thickness 0.049 316L SS

1/2" OD Tube Union, 316 SS


1/4" OD Tube Union, 316 SS
3/8" OD Tube Union, 316 SS

1/2"OD x 1/2" NPT Male Conn, 316 SS


3/8"OD x 1/2" NPT Male Conn, 316 SS

3/8" Fusible Plugs, 316 SS


3/8" OD Tubing- Wall Thickness 0.049 316L SS for FPL
3/8" Tube Union, 316 SS

TUBING STRUCTURAL SUPPORT - FABRICATOR TO ESTIMATE

INSTRUMENT AIR SUPPPLY ITEMS - E&I Subcontractor TO SUPPLY, CARRY OUT INSPECTION, INSTALLATION, ITR AND MECH
COMPLETION
INSTRUMENT AIR HEADER / SUBHEADER - by piping
INSTRUMENT AIR MANIFOLD (8 way)
1/2" BALL VALVES FOR MANIFOLD
1/2" BALL VALVES FOR FIELD INSTR

AIR MANIFOLD AND TUBING STRUCTURAL SUPPORT - FABRICATOR TO ESTIMATE

CABLE LADDER AND ACCESSORIES - E&I Subcontractor TO SUPPLY, CARRY OUT INSPECTION, INSTALLATION, ITR AND MECH
COMPLETION

STRAIGHT CABLE LADDER WITH COVER : 300MM WIDE


STRAIGHT CABLE LADDER WITH COVER : 450MM WIDE
STRAIGHT CABLE LADDER WITH COVER: 600MM WIDE
HORIZONTAL UNEQUAL TEE : 650MM/450MM/600MM WIDE
HORIZONTAL UNEQUAL TEE : 450MM/300MM/450MM WIDE

STRAIGHT CABLE TRAY WITH COVER : 50MM WIDE


STRAIGHT CABLE TRAY WITH COVER : 100MM WIDE
STRAIGHT CABLE TRAY WITH COVER : 150MM WIDE

CABLE LADDER AND TRAY STRUCTURAL SUPPORT - FABRICATOR TO ESTIMATE


CABLE LADDER AND TRAY ACCESSORIES, EARTHING, ETC, FABRICATOR TO ESTIMATE

INSTRUMENT CABLES - E&I Subcontractor TO SUPPLY, CARRY OUT INSPECTION, INSTALLATION, ITR AND MECH COMPLETION
(LV Cables 600V/1000V - Instrument Power)
2C X 2.5mm² IEC 60331
4C X 2.5mm² IEC 60331
12C X 2.5mm² IEC 60332
(Instrument & Communication Cables - Individual and Collective Screened cables)
1Pr X 1.5mm² IEC 60332
2Pr X 1.5mm² IEC 60332
5Pr X 1.0mm² IEC 60332
10Pr X 1.0mm² IEC 60332
20Pr X 1.0mm² IEC 60332
(Fire/Gas & Communication Cables - Individual and Collective Screened cables)
1Tr X 1.5mm² IEC 60331
1Pr X 1.5mm² IEC 60331
(Earthing Materials - Instrumentation)
EARTH CABLE - 6 SQ.MM
EARTH CABLE - 25 SQ.MM
EARTH BOSS ; M10 X 40MM DIA X 35MM LG. CW/ ACCESSORIES
(Glanding & Termination - Instrumentation)
1Pr X 1.5mm²
2Pr X 1.5mm²
5Pr X 1.0mm²
10Pr X 1.0mm²
20Pr X 1.0mm²
1Pr X 1.5mm²
1Tr X 1.5mm²
2C X 2.5mm²
4C X 2.5mm²
12C X 2.5mm²

Lighting and Small Power Cables

DESCRIPTION
DESCRIPTION

NORMAL LIGHTING CABLE


0.6/1kV 2CX2.5 Sq.mm COPPER ARMOURED/BRAIDED CABLE (RFOU)
0.6/1kV 2CX6 Sq.mm COPPER ARMOURED/BRAIDED CABLE (RFOU)

EMERGENCY LIGHTING CABLE


0.6/1kV 2CX2.5 Sq.mm COPPER ARMOURED/BRAIDED CABLE (BFOU)
0.6/1kV 2CX6 Sq.mm COPPER ARMOURED/BRAIDED CABLE (BFOU)
0.6/1kV 2CX4 Sq.mm COPPER ARMOURED/BRAIDED CABLE (BFOU)

Total
UNIT UOM Materials E&I Intallation

Unit rates Total rates Unit rate Total Rates

Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.

Nos.
Nos.

Nos.
Nos.
Nos.
Nos.
Nos.
Nos.

Nos.
Nos.
Nos.
Nos.

Nos.
Nos.

Nos.
Nos.
Nos.
Nos.

Nos.
Nos.
12 Nos. Free Issue -
Nos.
Nos.
6 Nos. Free Issue -
6 Nos. Free Issue -
3 Nos. Free Issue -
Nos.

3 Nos. Free Issue -


12 Nos. Free Issue -
2 Nos. Free Issue -
1 Nos. Free Issue -
1 Nos. Free Issue -

1 Nos. Free Issue -

1 Nos. - -
2 Nos. - -
1 Nos. - -

3 Nos. - -
24 Nos. - -
17 Nos. - -
5 Nos. - -
0 metre - -
0 Nos. - -
0 Nos. - -

0 Nos. - -
0 Nos. - -
0 Nos. - -

0 Nos. - -
0 Nos. - -

Nos.
metre
Nos.

1 Nos. - -
8 Nos. - -
1 Nos. - -

60 Mtr - -
100 Mtr - -
100 Mtr - -
4 nos - -
4 nos - -

240 Mtr - -
120 Mtr - -
60 Mtr - -
0 Mtr - -
0 Mtr - -
0 Mtr - -

0 Mtr - -
0 Mtr - -
Mtr
120 Mtr - -
120 Mtr - -

675 Mtr - -
725 Mtr - -

0 Mtr - -
98 Mtr - -
49 Nos. - -

0 Nos. - -
0 Nos. - -
0 Nos. - -
8 Nos. - -
8 Nos. - -
675 Mtr - -
54 Nos. - -
58 Nos. - -
0 Mtr - -
0 Mtr - -

MODULE 50 UNIT
MODULE 50 UNIT

600 M Free Issue -


120 M Free Issue -

375 M Free Issue -


100 M Free Issue -
M -

- -
PIPERACK 101 to 108

ELECTRICAL
Cable Ladder & Accessories

ITEM NO DESCRIPTION P101 TO P108

1.0 EARTHING ACCESSORIES


1.1 EARTH BOSS
50MM DIA -STAINLESS STEEL EARTHING BOSS C/W M10 STAINLESS STEEL
1.1.1 25
STUD, WASHER AND NUTS.
40MM DIA -STAINLESS STEEL EARTHING BOSS C/W M10 STAINLESS STEEL
1.1.2 STUD, WASHER AND NUTS.

EARTH BAR
1.2 50X6MM TINNED PLATED EARTH BAR (300mm TO 450mm LONG)

1.3 EARTHING CABLES

STRANDED COPPER CONDUCTOR, LOW SMOKE ZERO HALOGEN THERMOSET


COMPOUND INSULATED,INCLUSIVE OF NECESSARY COMPRESSION TYPE
COPPER LUGS COMPLETE WITH SS316L BOLTS, NUTS, FLAT WASHERS AND
SPRING WASHERS.

COLOUR: GREEN WITH YELLOW STRIPE.


1.3.1 1C X 6MM² 28
1.3.2 1C X 25MM² 58
1.3.3 1C X 70MM²
1.3.4 1C X 120MM²
1C X 70mm² EARTHING CABLE FOR PRE-COMMISSIONING/COMMISSIONING
1.3.5 EQUIPMENT.
1.3.6 SS136L CROCODILE CLIP SUITABLE FOR 70mm² EARTHING CABLE

Earthing accessories

ITEM NO DESCRIPTION P101 TO 108

1.0 EARTHING ACCESSORIES


1.1 EARTH BOSS
50MM DIA -STAINLESS STEEL EARTHING BOSS C/W M10 STAINLESS STEEL
1.1.1 25
STUD, WASHER AND NUTS.
40MM DIA -STAINLESS STEEL EARTHING BOSS C/W M10 STAINLESS STEEL
1.1.2 STUD, WASHER AND NUTS.

EARTH BAR
1.2 50X6MM TINNED PLATED EARTH BAR (300mm TO 450mm LONG)

1.3 EARTHING CABLES


STRANDED COPPER CONDUCTOR, LOW SMOKE ZERO HALOGEN THERMOSET
COMPOUND INSULATED,INCLUSIVE OF NECESSARY COMPRESSION TYPE
COPPER LUGS COMPLETE WITH SS316L BOLTS, NUTS, FLAT WASHERS AND
SPRING WASHERS.
COLOUR: GREEN WITH YELLOW STRIPE.
1.3.1 1C X 6MM² 28
1.3.2 1C X 25MM² 58
1.3.3 1C X 70MM²
1.3.4 1C X 120MM²
1C X 70mm² EARTHING CABLE FOR PRE-COMMISSIONING/COMMISSIONING
1.3.5 EQUIPMENT.
1.3.6 SS136L CROCODILE CLIP SUITABLE FOR 70mm² EARTHING CABLE

Lighting Fixtures & Small Power receptacles, Welding Sockets

ITEM No. DESCRIPTION P101 TO P108

1.0 DISTRIBUTION BOARDS AND ACCESSORIES


1.1 LIGHTING DISTRIBUTION BOARD

NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER ,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 18Nos.16A, 2P MCBs FOR OUTGOING, 18Nos. (M20) + 1 No. (M50)
1.1.1 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (RFOU) AND 4 Nos. (M20) Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUGS.

NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER ,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 18Nos.16A, 2P MCBs FOR OUTGOING, 18Nos. (M20) + 1 No. (M32)
1.1.2 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (RFOU) AND 6 Nos. (M20) Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUGS.

NORMAL LIGHTING AND SMALL POWER DISTRIBUTION BOARD, 230V, 3PH,


60Hz, 100A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB
HAZARDOUS AREA, WITH ANTI-CONDENSATION HEATER ,1No.100A, 3P,
MCCB FOR INCOMING CABLE, 2Nos.40A, 1 No. 32A,1 No. 25A and 11 Nos.
1.1.3 16A 2P MCBs FOR OUTGOING, 15Nos. (M20) + 1 No. (M32) Ex'de' IP66/67
BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS(MAKE
:HAWKE 501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE (RFOU)
AND 7 Nos. (M20) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUGS.
NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,
63A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER ,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 15Nos.16A, 2P MCBs FOR OUTGOING, 15Nos. (M20) + 1 No. (M40)
1.1.4 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (RFOU) AND 6 Nos. (M20) Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUGS.

NORMAL POWER DISTRIBUTION BOARD, 440V, 3PH, 60Hz,


250A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS
AREA, WITH ANTI-CONDENSATION HEATER ,1No.100A, 3P, MCCB FOR
INCOMING CABLE, 5 Nos.100A MCCBs FOR OUTGOING, 5Nos. (M63) + 1 No.
1.1.5 (GLAND SUITABLE FOR 3RX1CX120 sq.mm CABLES) Ex'de' IP66/67 BRASS
NICKEL PLATED DOUBLE COMPRESSION CABLE GLANDS(MAKE :HAWKE
501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE (RFOU) AND 4
Nos. (M63) Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUGS.

NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER ,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 18Nos.16A, 2P MCBs FOR OUTGOING, 18Nos. (M20) + 1 No. (M50)
1.1.6 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (RFOU) AND 3 Nos. (M20) Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUGS.

NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER ,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 12Nos.16A, 2P MCBs FOR OUTGOING, 12Nos. (M20) + 1 No. (M40)
1.1.7 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (RFOU) AND 5 Nos. (M20) Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUGS.

NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER ,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 21Nos.16A, 2P MCBs FOR OUTGOING, 21 Nos. (M20) + 1 No. (M40)
1.1.8 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (RFOU) AND 6 Nos. (M20) Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUGS.
NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,
63A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER ,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 12Nos.16A, 2P MCBs FOR OUTGOING, 12 Nos. (M20) + 1 No. (M32)
1.1.9 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (RFOU) AND 5 Nos. (M20) Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUGS.

NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER ,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 21 Nos.16A, 2P MCBs FOR OUTGOING, 21 Nos. (M20) + 1 No. (M50)
1.1.10 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (RFOU) AND 3 Nos. (M20) Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUGS.

NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER ,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 12 Nos.16A, 2P MCBs FOR OUTGOING, 12 Nos. (M20) + 1 No. (M50)
1.1.11 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (RFOU) AND 3 Nos. (M20) Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUGS.

NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER ,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 21 Nos.16A, 2P MCBs FOR OUTGOING, 21 Nos. (M20) + 1 No. (M32)
1.1.12 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (RFOU) AND 5 Nos. (M20) Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUGS.

NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER ,1No.63A, 3P, MCCB FOR INCOMING
1.1.13 CABLE, 21 Nos.16A, 2P MCBs FOR OUTGOING, 21 Nos. (M20) + 1 No. (M50)
Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (RFOU) AND 5 Nos. (M20) Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUGS.

NORMAL LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA,
WITH ANTI-CONDENSATION HEATER ,1No.63A, 3P, MCCB FOR INCOMING
CABLE, 18 Nos.16A, 2P MCBs FOR OUTGOING, 18 Nos. (M20) + 1 No. (M50)
1.1.14 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS(MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (RFOU) AND 6 Nos. (M20) Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUGS.
EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,
63A,MINIMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS
AREA, WITH ANTI-CONDENSATION HEATER,1No.63A, 3P, MCCB FOR
INCOMING CABLE, 12Nos.16A, 2P MCBs FOR OUTGOING, 12Nos. (M20) + 1
1.1.15 No. (M40) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION
CABLE GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (BFOU) AND 8 Nos. (M20) Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINIMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS
AREA, WITH ANTI-CONDENSATION HEATER,1No.63A, 3P, MCCB FOR
INCOMING CABLE, 15Nos.16A, 2P MCBs FOR OUTGOING, 15Nos. (M20) + 1
1.1.16 No. (M32) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION
CABLE GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (BFOU) AND 3 Nos. (M20) Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINIMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS
AREA, WITH ANTI-CONDENSATION HEATER,1No.63A, 3P, MCCB FOR
INCOMING CABLE, 18Nos.16A, 2P MCBs FOR OUTGOING, 18Nos. (M20) + 1
1.1.17 No. (M40) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION
CABLE GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (BFOU) AND 4 Nos. (M20) Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINIMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS
AREA, WITH ANTI-CONDENSATION HEATER,1No.63A, 3P, MCCB FOR
INCOMING CABLE, 12Nos.16A, 2P MCBs FOR OUTGOING, 12Nos. (M20) + 1
1.1.18 No. (M40) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION
CABLE GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (BFOU) AND 6 Nos. (M20) Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINIMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS
AREA, WITH ANTI-CONDENSATION HEATER,1No.63A, 3P, MCCB FOR
INCOMING CABLE, 9Nos.16A, 2P MCBs FOR OUTGOING, 9 Nos. (M20) + 1 No.
1.1.19 (M40) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (BFOU) AND 5 Nos. (M20) Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUGS.
EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,
63A,MINIMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS
AREA, WITH ANTI-CONDENSATION HEATER,1No.63A, 3P, MCCB FOR
INCOMING CABLE, 24 Nos.16A, 2P MCBs FOR OUTGOING, 24 Nos. (M20) + 1
1.1.20 No. (M40) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION
CABLE GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (BFOU) AND 3 Nos. (M20) Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINIMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS
AREA, WITH ANTI-CONDENSATION HEATER,1No.63A, 3P, MCCB FOR
INCOMING CABLE, 18 Nos.16A, 2P MCBs FOR OUTGOING, 18 Nos. (M20) + 1
1.1.21 No. (M50) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION
CABLE GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (BFOU) AND 4 Nos. (M20) Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINIMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS
AREA, WITH ANTI-CONDENSATION HEATER,1No.63A, 3P, MCCB FOR
INCOMING CABLE, 18 Nos.16A, 2P MCBs FOR OUTGOING, 18 Nos. (M20) + 1
1.1.22 No. (M50) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION
CABLE GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (BFOU) AND 3 Nos. (M20) Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINIMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS
AREA, WITH ANTI-CONDENSATION HEATER,1No.63A, 3P, MCCB FOR
INCOMING CABLE, 9Nos.16A, 2P MCBs FOR OUTGOING, 9 Nos. (M20) + 1 No.
1.1.23 (M32) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (BFOU) AND 5 Nos. (M20) Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINIMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS
AREA, WITH ANTI-CONDENSATION HEATER,1No.63A, 3P, MCCB FOR
INCOMING CABLE, 18Nos.16A, 2P MCBs FOR OUTGOING, 18 Nos. (M20) + 1
1.1.24 No. (M32) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION
CABLE GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (BFOU) AND 5 Nos. (M20) Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUGS.
EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,
63A,MINIMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS
AREA, WITH ANTI-CONDENSATION HEATER,1No.63A, 3P, MCCB FOR
INCOMING CABLE, 15 Nos.16A, 2P MCBs FOR OUTGOING, 15 Nos. (M20) + 1
1.1.25 No. (M40) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION
CABLE GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (BFOU) AND 3 Nos. (M20) Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINIMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS
AREA, WITH ANTI-CONDENSATION HEATER,1No.63A, 3P, MCCB FOR
INCOMING CABLE, 15 Nos.16A, 2P MCBs FOR OUTGOING, 15 Nos. (M20) + 1
1.1.26 No. (M32) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION
CABLE GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (BFOU) AND 4 Nos. (M20) Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINIMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS
AREA, WITH ANTI-CONDENSATION HEATER,1No.63A, 3P, MCCB FOR
INCOMING CABLE, 18Nos.16A, 2P MCBs FOR OUTGOING, 18 Nos. (M20) + 1
1.1.27 No. (M50) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION
CABLE GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (BFOU) AND 6 Nos. (M20) Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUGS.

EMERGENCY LIGHTING DISTRIBUTION BOARD, 230V, 3PH, 60Hz,


63A,MINIMUM(IP56), Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS
AREA, WITH ANTI-CONDENSATION HEATER,1No.63A, 3P, MCCB FOR
INCOMING CABLE, 21Nos.16A, 2P MCBs FOR OUTGOING, 21 Nos. (M20) + 1
1.1.28 No. (M40) Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION
CABLE GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (BFOU) AND 4 Nos. (M20) Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUGS.

UPS DISTRIBUTION BOARD, 230V, 3PH, 60Hz, 100A,MINIMUM(IP56), Ex'd',


T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-
CONDENSATION HEATER,1No.100A, 3P, MCCB FOR INCOMING CABLE, 6
Nos.16A,9 Nos. 10A, 2P MCBs FOR OUTGOING, 15 Nos. (M20) + 1 No. (M32)
1.1.29 Ex'de' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE (RFOU) AND 7 Nos. (M20) Ex`d' IP66/67
BRASS NICKEL PLATED BLOCKING PLUGS.
ESSENTIAL DISTRIBUTION BOARD, 440V, 3PH, 60Hz, 250A,MINMUM(IP56),
Ex'd', T3, SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH ANTI-
CONDENSATION HEATER ,1No.100A, 3P, MCCB FOR INCOMING CABLE, 5
Nos.100A MCCBs FOR OUTGOING, 5Nos. (M63) + 1 No. (GLAND SUITABLE
1.1.30 FOR 3RX1CX120 sq.mm CABLES) Ex'de' IP66/67 BRASS NICKEL PLATED
DOUBLE COMPRESSION CABLE GLANDS(MAKE :HAWKE 501/453/UNIV)
SUITABLE FOR ARMOURED/BRAIDED CABLE (RFOU) AND 4 Nos. (M63) Ex`d'
IP66/67 BRASS NICKEL PLATED BLOCKING PLUGS.

1.2 LIGHTING JUNCTION BOX

LIGHTING JUCTION BOX INCREASED SAFETY Ex'e' IIB T3,IP56 WITH 3 Nos.
(M20) CABLE ENTRIES, 3 Nos. (M20) Ex'de' IP66/67 BRASS NICKEL PLATED
1.2.1 CABLE GLAND (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR TERMINATION 9
OF 2C X 2.5/6 Sq.mm ARMOURED CABLE (TYPE -RFOU /BFOU) AND 1No.
(M20) Ex'd' IP66/67 BRASS NICKEL PLATED BLOCKING PLUG.

LIGHTING JUCTION BOX INCREASED SAFETY Ex'e' IIB T3,IP56 WITH 4 Nos.
(M20) CABLE ENTRIES, 4 Nos. (M20) IP66/67 BRASS NICKEL PLATED CABLE
1.2.2 GLAND SUITABLE FOR TERMINATION OF 3C X 2.5/6 Sq.mm ARMOURED
CABLE (TYPE - LV1 / LV2) AND 1No. (M20) IP66/67 BRASS NICKEL PLATED
BLOCKING PLUG.

2.0 LIGHT FIXTURES AND ACCESSORIES


2.1 FLUORESCENT LIGHT FIXTURES(2X36W)

FLUORESCENT LIGHT FIXTURE IP66/67, Ex 'e', T3, SUITABLE FOR ZONE-1 IIB
HAZARDOUS AREA, WITH 2x36W FLOURESCENT LAMP(TL-D 36W/840 OF
PHILIPS) 230V, 1PH(LINE TO LINE), 60Hz, INTEGRAL CONTROL GEAR BOX,
2xM20 CABLE ENTRY AND 2 Nos. (M20) EX'de' IP66/67 BRASS NICKEL
3
PLATED DOUBLE COMPRESSION CABLE GLANDS(MAKE :HAWKE
501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE (RFOU/BFOU )
AND 1 No. (M20)Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUG.
(CHALMIT CAT. REFERENCE: PRGE/236/BI) OR APPROVED EQUIVALENT

BRACKET MOUNTED - MOUNTING BRACKET AND ACCESSORIES (NORMAL


2.1.1 POWER SUPPLY)
SUSPENSION MOUNTED - MOUNTING ACCESSORIES (NORMAL POWER
2.1.2 SUPPLY)
DOUBLE POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (NORMAL
2.1.3 POWER SUPPLY)
SINGLE POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (NORMAL
2.1.4 POWER SUPPLY)
2.1.5 HANDRAIL MOUNTED - ACCESSORIES (NORMAL POWER SUPPLY)
BRACKET MOUNTED - MOUNTING BRACKET AND ACCESSORIES (UPS
2.1.6 POWER SUPPLY)

2.1.7 SUSPENSION MOUNTED - MOUNTING ACCESSORIES (UPS POWER SUPPLY) 2


DOUBLE POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (NORMAL
2.1.8 POWER SUPPLY)
SINGLE POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (UPS POWER
2.1.9 1
SUPPLY)
2.1.10 HANDRAIL MOUNTED - ACCESSORIES (UPS POWER SUPPLY)

2.2 FLUORESCENT LIGHT FIXTURES(2X18W)

FLUORESCENT LIGHT FIXTURE IP66/67, Ex 'e', T3, SUITABLE FOR ZONE-1 IIB
HAZARDOUS AREA, WITH 2x18W FLOURESCENT LAMP(TL-D 18W/840 OF
PHILIPS) 230V, 1PH(LINE TO LINE), 60Hz, INTEGRAL CONTROL GEAR BOX,
2xM20 CABLE ENTRY AND 2 Nos. (M20) EX'de' IP66/67 BRASS NICKEL
PLATED DOUBLE COMPRESSION CABLE GLANDS(MAKE :HAWKE
501/453/UNIV) SUITABLE FOR ARMOURED/BRAIDED CABLE (RFOU/BFOU )
AND 1 No. (M20)Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUG.
(CHALMIT CAT. REFERENCE: PRGE/218/BI) OR APPROVED EQUIVALENT

2.2.1 HANDRAIL MOUNTED - MOUNTING ACCESSORIES (NORMAL POWER SUPPLY)


2.2.2 HANDRAIL MOUNTED - MOUNTING ACCESSORIES (UPS POWER SUPPLY)
2.2.3 SUSPENSION MOUNTED - MOUNTING ACCESSORIES (UPS POWER SUPPLY)

2.3 FLOOD LIGHT FIXTURES - 400W (WIDE BEAM)

FLOOD LIGHT FIXTURE - ASYMMETRICAL TYPE IP66/67, Ex 'de', T3, SUITABLE


FOR ZONE-1 IIB HAZARDOUS AREA, WITH 400W METAL HALIDE LAMP -
230V, 1PH(LINE TO LINE), 60Hz, INTEGRAL CONTROL GEAR BOX, 2xM20
CABLE ENTRY AND 2 Nos. (M20) Ex'de' BRASS NICKEL PLATED DOUBLE 2
COMPRESSION CABLE GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE
FOR ARMOURED/BRAIDEDCABLE (TYPE - RFOU / BFOU) AND 1 No. (M20)
Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUG. (CHALMIT CAT.
REFERENCE: EV2D/400/MS/60) OR APPROVED EQUIVALENT

2.3.1 POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (NORMAL POWER SUP 2
2.3.2 POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (UPS POWER SUPPLY)
2.3.3 BRACKET MOUNTED - MOUNTING BRACKET AND ACCESSORIES (UPS POWER SUPPLY)

2.4 LED FLOOD LIGHT FIXTURE (34W)-WIDE BEAM

FLOOD LIGHT FIXTURE WITH WIDE BEAM IP66/67, Ex 'de', T3, SUITABLE FOR
ZONE-1 IIB HAZARDOUS AREA, WITH 34W HIGH POWER LIGHT EMITTING
DIODES(LEDs) - 230V, 1PH(LINE TO LINE), 60Hz, INTEGRAL CONTROL GEAR
BOX,2xM20 CABLE ENTRY AND 2 Nos. (M20) EX'de' BRASS NICKEL PLATED 7
DOUBLE COMPRESSION CABLE GLANDS (MAKE :HAWKE 501/453/UNIV)
SUITABLE FOR ARMOURED/BRAIDED CABLE (RFOU/BFOU) AND 1 No.(M20)
Ex'd' IP66/67 BRASS NICKEL PLATED BLOCKING PLUG. (CHALMIT CAT.
REFERENCE: SOLD/034/LE) OR APPROVED EQUIVALENT

BRACKET MOUNTED - MOUNTING BRACKET AND ACCESSORIES (NORMAL


2.4.1 POWER SUPPLY)
POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (NORMAL POWER
2.4.2 SUPPLY)
BRACKET MOUNTED - MOUNTING BRACKET AND ACCESSORIES (UPS
2.4.3 7
POWER SUPPLY)
POLE MOUNTED - MOUNTING POLE AND ACCESSORIES (UPS POWER
2.4.4 SUPPLY)

2.5 LED FLOOD LIGHT FIXTURE (125W)-WIDE BEAM

FLOOD LIGHT FIXTURE WITH WIDE BEAM IP66/67, Ex 'de', T3, SUITABLE FOR
ZONE-1 IIB HAZARDOUS AREA, WITH 125W HIGH POWER LIGHT EMITTING
DIODES(LEDs) - 230V, 1PH(LINE TO LINE), 60Hz, INTEGRAL CONTROL GEAR
BOX,2xM20 CABLE ENTRY AND 2 Nos. (M20) EX'de' BRASS NICKEL PLATED 5
DOUBLE COMPRESSION CABLE GLANDS (MAKE :HAWKE 501/453/UNIV)
SUITABLE FOR ARMOURED/BRAIDED CABLE (RFOU/BFOU) AND 1 No.(M20)
Ex'd' IP66/67 BRASS NICKEL PLATED BLOCKING PLUG. (CHALMIT CAT.
REFERENCE: SOLD/12L/LE) OR APPROVED EQUIVALENT

BRACKET MOUNTED - MOUNTING BRACKET AND ACCESSORIES (NORMAL


2.5.1 3
POWER SUPPLY)

2.5.2 POLE MOUNTED - MOUNTING POLE ACCESSORIES (NORMAL POWER


SUPPLY)
BRACKET MOUNTED - MOUNTING BRACKET AND ACCESSORIES (UPS
2.5.3 2
POWER SUPPLY)

2.5.4 POLE MOUNTED - MOUNTING POLE ACCESSORIES (UPS POWER SUPPLY)

2.6 AERONAUTICAL OBSTRUCTION LIGHT

MEDIUM INTENSITY, ICAO TYPE C (STEADY BURNING, RED COLOUR)


AERONAUTICAL OBSTRUCTION LIGHT COVERED WITH HEAT SHIELD Ex`d' IIC
T6, IP66 SUITABLE FOR ZONE-1 IIB HAZARDOUS AREA, WITH 35W LED LIGHT
230V, 1PH, 60Hz, INTEGRAL CONTROL GEAR BOX, 2xM20 CABLE ENTRY AND
2 Nos. (M20) Ex`d' BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE
2.6.1 GLANDS SUITABLE FOR 2C X 4sq.mm HEAVY DUTY TYPE COPPER
CONDUCTOR / COMPRESSED MINERAL INSULATION COPPER SHEATH CABLE
(TYPE-MI) WITH BLOCKING PLUG. (CLAMP CATALOGUE REFERENCE :
SEGS23C2K (MEDIUM INTENSITY TYPE) OR APPROVED EQUIVALENT.

2.7 HEAT SHIELD FOR OBSTRUCTION LIGHT:


HEAT SHIELD (POINT LIGHTING CATALOGUE REF : PL40139-SS) OR APPROVED
EQUIVALENT.
2.7.1

3.0 SOCKET OUTLETS & PLUGS


3.1 16A OUTDOOR POWER SOCKET
POWER SOCKET WITH INTERLOCKING SWITCH AND MATCHING PLUG, 230V,
16A, 1PH(LINE TO LINE),3PIN(2P+E), IP56, Ex`de', T3, SUITABLE FOR ZONE-1
IIB HAZARDOUS AREA. POWER SOCKET: WITH 2xM20 CABLE ENTRIES, 1
No.M20 IP66/67, Ex`de' BRASS NICKEL PLATED DOUBLE COMPRESSION
3.1.1 CABLE GLANDS (MAKE :HAWKE 501/453/UNIV) SUITABLE FOR
ARMOURED/BRAIDED CABLE AND 1 No.M20 Ex`d' IP66/67 BRASS NICKEL
PLATED BLOCKING PLUG. POWER PLUG: WITH Ex'd' IP66/67 CABLE GLAND
ENTRY SUTABLE FOR 2Cx6 SQMM EPR/XLPE INSULATED AND BRAIDED
FLEXIBLE CABLE .

3.2 LVSR CONNECTORS & RECEPTACLES FOR PIGTAIL CONNECTIONS


CONNECTOR PLUG (CP) WITH CAP
Ex'd', CONNECTOR PLUG (CP) FROM LVSR (HAWKE CAT. REF. Ex'd-32-N-CP-B-
3.2.1 1-120-S-FPC-A)
Ex'd', CONNECTOR PLUG (CP) FROM LVSR (HAWKE CAT. REF. Ex'd-32-N-CP-B-
3.2.2 1-95-S-FPC-A)

CONNECTOR RECEPTACLES (CR) WITH CAP


Ex'd', CONNECTOR PLUG (CR) TO DISTRIBUTION BOARD (HAWKE CAT. REF.
3.2.3 Ex'd-32-N-CR-B-1-120-P-FRC-A)
Ex'd', CONNECTOR PLUG (CR) TO DISTRIBUTION BOARD (HAWKE CAT. REF.
3.2.4 Ex'd-32-N-CR-A-1-95-P-FRC-A)

4.0 WELDING RECEPTACLE

WELDING RECEPTACLE WITH INTERLOCKING SWITCH AND MATCHING PLUG,


440V, 60Hz, 63A, 3PH, 4PIN (3P+PE), IP56, Ex`de', T3, SUITABLE FOR ZONE-1
IIB HAZARDOUS AREA, WITH 2XM40 CABLE ENTRIES, AND TERMINALS
4.1.1 SUITABLE FOR 3CX50SQMM CABLES, 2 Nos. IP66/67, Ex`d BRASS NICKEL
PLATED DOUBLE COMPRESSION CABLE GLANDS SUITABLE FOR ARMOURED
CABLE AND 1 No. Ex`d' IP66/67 BRASS NICKEL PLATED BLOCKING PLUG.

5.0 ELECTRICAL POWER JUNCTION BOX


5.1.1 ELECTRICAL POWER JUNCTION BOX

6.0 AERONAUTICAL OBSTRUCTION LIGHT JUNCTION BOX


ELECTRICAL JUNCTION BOX, SS316L, IP 66 Ex`d', T3, SUITABLE FOR ZONE-1
IIB HAZARDOUS AREA, WITH EXTERNAL BRASS EARTHING STUD AND 1No.
(M20) CABLE ENTRY AND 1No.(M20) IP66/67 Ex'd' BRASS NICKEL PLATED
DOUBLE COMPRESSION CABLE GLANDS SUITABLE FOR 2C x 6sq.mm x
LPF/EPR INSULATED FIRE RESISTANT (MGT) AND ARMOURED CABLE FROM
MODULE - 20 EMERGENCY LIGHTING DB AND 1No.(M20) CABLE ENTRY WITH
6.1.1 Ex`d' IP66/67 BRASS NICKEL PLATED DOUBLE COMPRESSION CABLE GLAND
SUITABLE FOR 2C X 4sq.mm HEAVY DUTY TYPE COPPER CONDUCTOR /
COMPRESSED MINERAL INSULATION COPPER SHEATH CABLE (TYPE-MI) TO
OBSTRUCTION LIGHT (25-LTG-7852-01/01M/2M) ON FLARE TOWER LEVEL
EL.+83150 AND (25-LTG-7852-01/01N/2N) ON FLARE TOWER LEVEL EL.
+118150.

7.0 POWER CABLE


7.1. MINERAL INSULATED POWER CABLE
7.1.2 POWER CABLE

8.1 AERONAUTICAL OBSTRUCTION LIGHT CABLE

Lighting and Small Power Cables

ITEM No. DESCRIPTION P101 TO P108

1.1 NORMAL LIGHTING CABLE


1.1.1 0.6/1kV 2CX2.5 Sq.mm COPPER ARMOURED/BRAIDED CABLE (RFOU) 220
1.1.2 0.6/1kV 2CX6 Sq.mm COPPER ARMOURED/BRAIDED CABLE (RFOU) 40

1.2 EMERGENCY LIGHTING CABLE


1.2.1 0.6/1kV 2CX2.5 Sq.mm COPPER ARMOURED/BRAIDED CABLE (BFOU) 570
1.2.2 0.6/1kV 2CX6 Sq.mm COPPER ARMOURED/BRAIDED CABLE (BFOU) 40
1.2.3 0.6/1kV 2CX4 Sq.mm COPPER ARMOURED/BRAIDED CABLE (BFOU)

Total
Materials E&I Intallation

UNIT Unit rates Total rates Unit rate Total Rates

Nos. Free Issue -

Nos.

Nos.

M Free Issue -
M Free Issue -
M
M

Nos.

UNIT

Nos. Free Issue -

Nos.
Nos.

M Free Issue -
M Free Issue -
M
M

Nos.

UNIT

Nos

Nos

Nos.
Nos.

Nos.

Nos.

Nos.

Nos.
Nos.

Nos.

Nos.

Nos.

Nos.

Nos.
Nos.

Nos.

Nos.

Nos.

Nos.
Nos.

Nos.

Nos.

Nos.

Nos.
Nos.

Nos.

Nos.

Nos.

Nos.
Nos.

Nos. Free Issue -

Nos.

Nos Free Issue -

Nos

Nos

Nos

Nos

Nos

Nos

Nos Free Issue -


Nos

Nos Free Issue -

Nos

Nos

Nos
Nos
Nos

Nos Free Issue -

Nos Free Issue -


Nos
Nos

Nos Free Issue -

Nos

Nos
Nos Free Issue -

Nos

Nos Free Issue -

Nos Free Issue -

Nos

Nos Free Issue -

Nos

Nos

Nos
Nos

Nos

Nos

Nos

Nos

Nos

Nos.
Nos.

M
M

UNIT

M Free Issue -
M Free Issue -

M Free Issue -
M Free Issue -
M

- -
HELIDECK

Heli Deck Requirements

The helideck SHALL comply with IMO MODU Code, ICAO ANNEX 14 VOL II and UK Civil Aviation
Authority publication CAP 437 Offshore Helicopter Landing Areas - Guidance on Standards, and
Company Aviation Standard.

Main Characteristics
following requirements (based on S92 helicopter type):
The helideck SHALL, as minimum comply with the
• Certified as per UK Civil Aviation Authority publication CAP 437
Offshore Helicopter Landing Areas - Guidance on Standards or
equivalent
• D value 20 m
• t Value 11 t (dynamic impact as per ICAO definition)
• Tiedown points: available as specified in ICAO ANNEX 14/CAP437
• Drainage: be present. Appropriate drainage system from helideck
into safe storage place
• Helideck painting/daylight visual markings: standard as ICAO ANNEX
14/CAP 437.
• Friction Capability: not less than 0,65 (last friction test available)
• Surface landing net: be provided
• Perimeter landing net: as specified on CAP 437/UKOOA
• Helideck lighting: perimeter, flood, windsock and general
lighting (also connected to UPS) as specified on ICAO ANNEX 14/Cap
437
• Obstruction on helideck: less than 25 cm height
• Obstruction on 150° obstacle sector: as specified on ICAO ANNEX
14/Cap 437
• Obstruction on 210° obstacle free sector: as specified on ICAO
ANNEX 14/Cap 437
• Helideck Status or warning light/s: present ICAO ANNEX 14/Cap 437
• Refuelling unit: as specified by Regulation (CAP 437,ICAO,OGP)
• Access points: not less than 2
• Emergency Exit: one
• Fire protection systems: as specified by ICAO ANNEX 14/Cap
437for H2 helidecks
• Rescue Equipment/PPI: not less than specified on ICAO ANNEX
14/Cap 437CAP 437
• Radio Equipment: VHF main plus portable, NDB (non directional
beacon)
• Weather Equipment: meteo station be present (anemometer, air
temp, barometer, general visibility and cloud base)
• Helideck Crew: 1HLO, 2HDA, 2firefighting personnel (OPITO
standard course)

Bill of Quantities
Description Qty
Helideck Primary 150
Helideck Safety Net Supply and Install 1
Helideck Safety Rope Supply and Install 1
Helideck – H Circle and H Illuminated Lights 1
Perimeter and Status Lights 1
Helideck Painting 1500
UOM
Ton
Lot
Lot
Lot
Lot
M2

Вам также может понравиться