• Custody Transfer
• Compressor Stations
• Gas Pressure Reducing Skids
• Remote Station Monitoring
• Gas Storage
• City/Regional Gas Suppliers
• Biogas Applications
Robust Functionality
The ERZ 2000-NG base module The random access memory
System Configurations performs neutral measurements of contains the variables, fields and
all inputs similar to a multimeter, but buffers required for running the
The ERZ 2000-NG Series no calculations or assignments to system software and the changeable
is designed as a universal physical units are made. Therefore, device parameters of all functional
instrument, which can be used the unit only deals with analog modules. The parameters are
for all metrological tasks in a gas values, frequencies and meter protected by means of a checksum,
metering station. The flow computer contents without knowing the which is automatically verified with
is available in a choice of system meaning of individual values. The each new start of the system.
configurations, including: measured values are assigned to the
appropriate physical quantities and Parameters relevant for custody
ERZ 2002-NG Density converted into usable data. The base transfer metering are protected by
Corrector module also provides all outputs a sealable switch, the others by a
Calculates gas volume at base and data interfaces, as well as three code number. The program memory
conditions via density, standard spare slots for hardware extensions contains the operating program for
density and velocity of sound. and future requirements. the device. A CRC checksum is
calculated via the source code and
ERZ 2004-NG Volume The ERZ 2000-NG employs a deposited as a reference value.
Corrector powerful microprocessor system
Calculates gas volume at base based on an ARM CPU with an
conditions via pressure, temperature associated program memory (flash
and K co-efficient (PTZ). memory), random access memory
and data memory.
ERZ 2104-NG Calorific Value
Corrector (PTZ)
Calculates gas volume at base
conditions via pressure, temperature
and K co-efficient and energy
content with gas quality.
Data Logging
The ERZ 2000-NG includes a data
logger providing conventional data
logging and the DSfG archive
Touchscreen HMI Original Totalizer Readings (i.e., a data memory recording data
Intuitive touchscreen user interface In the case of gas meters with generated in the corrector and
simplifies system commissioning, encoders, it is possible to digitally transmitted via the DSfG interface).
maintenance and operation, displaying transmit their readings to the
key information in well structured ERZ 2000-NG so the original readings Error Curve Linearization
tabs. For example, measurement data are available in the corrector. During high-pressure testing of a gas
and totalizers are visible at a glance meter, its error curve (which depends
as defined by approval authorities. Digital Inputs for on the flow rate) is determined. This
The operator can also view tools Measured Values error curve can be simulated in the
for commissioning, maintenance As an alternative to analog ERZ 2000-NG gas volume corrector
and calibration. Additionally, the transmission of measured values from as interpolation points, or as a
HMI presents tables of all detailed pressure transmitters and resistance polynomial applied over the flow rate
measurement data, parameters, thermometers, the values can also be or the Reynolds Number. As such,
archives; events and alarm log transmitted digitally in conformity with the error of measurement can be
information; and trend graphs. the HART protocol. eliminated.
Bus Interface
The device has standard interfaces for
Modbus-Slave (RTU/ASCII), DSfG and
RMG Bus, and Modbus-IP.
Hazardous area No
• Intuitive
HMI for a new experience in navigating through the flow computer for
commissioning, maintenance, operation and data reading
• Calculationof the theoretical Velocity of Sound for online comparison with measured
VOS from USM
• In connection with turbine meter, vortex meter, ultrasonic meter, rotary displacemeter
and orifice plate
• Four-set of totalizers for Vm, Vb, energy, mass flow and CO2 (disturbed and undisturbed)