Вы находитесь на странице: 1из 2

GE OEC 9800 C-Arm

The GE OEC 9800 C-Arm is a multi-application


AR
R ANT Y mobile X-ray imaging system that provides solutions

for the most demanding needs in Pain Management,
★★




★★★



General, Orthopedic, Vascular, Neurovascular and


★★
★★
★★

★ S OM
★★ ★★

Cardiac Surgeries. The OEC 9800 is the benchmark



N
★★

for fluoroscopy applications and X-ray technology with


I


Y,

★★
TE
★★


L OG
★ ★★
★★ ★

a true 1K x 1K high resolution CCD camera, touch


screen operations, high image quality with low X-ray
dosage, crisp, clear images, superior penetration
power with a 15 kW generator and excellent resolution.

Soma Technology Inc. • 166 Highland Park Drive • Bloomfield, CT 06002 • USA
Phone: 1.800.GET.SOMA • www.SomaTechnology.com • Email: soma@somatechnology.com

Revised 9/07/2012
GE OEC 9800 C-Arm
X-Ray System Pulsed Fluoroscopy Mode Video Camera
• Focal spot: 0.3 mm • High resolution CCD camera
Specialty Packages Available • kVp range: 40 – 120 kVp • 1,004 x 1,004 pixels
• GSP • mA range: 0.2 – 10 mA • Full frame capture
• ESP • Pulse rate: 1, 2, 4, or 8 pulses per • 360° motorized rotation
• ESP 8 FPS second • On-screen orientation indicator (real-
• Vascular • Pulse width: 30 or 50 milliseconds time feedback without fluoro)
• Vascular 8/15 FPS • Computer controlled ABS, mA, kVp and • Left-right image reversal
• Neurovascular 30 FPS camera gain • Top-bottom image reversal
• Cardiac 30 FPS • Negative mode
• Super C Pulsed Fluorography Mode • Computer controlled features:
(optional) - Gain
Generator • Focal spot: 0.3 mm - Blanking
• 60 kHz High frequency • kVp range: 40 – 120 kVp - Camera iris
• 15 kW full-wave • mA range: Up to 40 mA
• Up to 120 kVp • Pulse rate: 1, 2, 4, or 8 pulses per Video Monitors
• Up to 75 mA for radiographic film second • Dual 16 in, black etched, anti-glare,
exposures • Pulse width: 30 or 50 milliseconds anti-static
• Continuous fluoro boost mode up to 20 • Computer controlled camera iris, mA, • Touch Screen Display
mA kVp, & camera gain • Ambient room light sensor
• Pulsed fluoro mode • Multi-LED X-ray “ON” indicator
• Pulsed fluorography mode up to 40 mA Digital Spot Mode • Remote window/level controls
(optional) • Focal spot: 0.3 mm
• Full power from outlet: • kVp range: 40 – 120 kVp Hardcopy Options
- 50 Hz or 60 Hz • mA range: 1.0 – 75 mA • Thermal printer (optional)
- 100V-15A to 240V-10A • Automatically terminates exposure • DICOM (optional)
• Patented energy buffer design and stores enhanced image to storage • Image Capture Device (optional)
archival disk • Laser aiming device (optional)
X-Ray Tube
• Rotating anode X-ray tube Radiographic Mode C-Arm Dimensions
• Focal spots: 0.3 mm and 0.6 mm • Focal spot: 0.3 mm or 0.6 mm • Height: 69 / 87 in (1734 / 2191 mm)
• Anode heat capacity: 300,000 HU • Focal spot automatically selected • Width: 33 in (838 mm)
• Anode cooling rate: 60,000 HU/min • kVp range: 50 – 120 kVp • Length: 79 in (1994 mm)
• Housing heat capacity: 1,600,000 HU • 0.3 mm - mAs range: 1 – 100 mAs • Weight: 720 lbs
• Anode diameter: 3.1 in • 0.6 mm - mAs range: 110 – 300 mAs
• Anode angle: 10° Workstation Dimensions
• X-ray tube cooling fan (Vascular, Video Imaging System • Height: 64 in (1632 mm)
Neurovascular & Cardiac units) • Width: 27 in (692 mm)
Image Intensifier • Depth: 27 in (692 mm)
Collimator • Weight: 430 lbs.
• Iris collimation with dual opposing semi- 9 in Image Intensifier
transparent leaf shutters allow elliptical, • Tri-mode 9 in/6 in/4.5 in image
round and rectangular collimation intensifier
• Minimum beam size < 5 X 5 cm2 - 9 in.: 2.3 lp/mm
• Iris and shutters are continuously - 6 in.: 3.2 lp/mm
variable - 4.5 in.: 3.8 lp/mm
• All functions remotely controlled from • DQE: 65% (typical)
the C-Arm control panel
12 in Image Intensifier (optional)
Fluoroscopy Mode • Tri-mode 12 in/9 in/6 in image
• Focal spot: 0.3 mm intensifier
• kVp range: 40 – 120 kVp - 12 in.: 1.7 lp/mm
• mA range: 0.2 – 10 mA normal mode - 9 in.: 2.3 lp/mm
• mA range: 0.2 – 20 mA continuous - 6 in.: 3.0 lp/mm
fluoro boost mode • DQE: 65% (typical)
• Auto and manual modes Soma Technology Inc.
• Continuous, one-shot or pulsed
166 Highland Park Drive
operation
Bloomfield, CT 06002 • USA
• ABS varies mA, kVp and camera gain
• User specific ABS tables 1.800.438.7662
www.SomaTechnology.com

Note: The technical data given in this publication is for general information and are subject to change without notice. Actual configuration on
the unit may vary. Contact our sales representatives for a complete list of details.

Вам также может понравиться