SGT-600 Industrial Gas Turbine

Power Generation: (ISO) 24.77 MW(e)

The SGT-600 is the most efficient and environmentally friendly industrial gas
turbine in its power range. The robustness of the industrial design ensures high
reliability and availability in all environments and applications.

The Siemens SGT-600 is a heavy-duty The outstanding reliability of the SGT-600


industrial gas turbine designed and built makes it ideal for interdependent multi-
to meet requirements for low life-cycle unit applications.
cost, i.e. low first cost, low fuel costs and A single-lift power generation module for
low costs for operation and maintenance. floating platforms such as FPSO (Floating
Low fuel consumption, even at part loads, Production, Storage and Offloading) and
and short installation and commissioning semi-submersibles is available for both the
times are major features of this turbine. SGT-600 and the SGT-700.
In cogeneration and combined-cycle The SGT-600 uses a Dry Low Emission
applications, the high exhaust temperature (DLE) system maintaining low specific
of the gas turbine makes it one of the most fuel consumption in all applications.
efficient units on the market. The SGT-600 The system is both stable and reliable,
is even able to perform durably in aggres- not requiring frequent recalibration,
sive industrial environments under really and coping easily with load changes,
tough operating conditions, whether on- planned or otherwise.
shore or offshore, in arctic or desert climate.

Industrial Gas Turbines

Answers for energy.


SGT-600 Industrial Gas Turbine

SGT-600 gas generator.

Technical specifications Gas turbine:


Overview Bearings Key features
• Power generation: 24.77 MW(e) • Tilting pad radial and thrust Robust industrial design
• Frequency: 50/60 Hz • Vibration- and temperature- Low fuel consumption, high efficiency
• Electrical efficiency: 34.2 % monitoring Excellent DLE experience
• Heat rate: 10,533 kJ/kWh Low emissions – DLE ≤25 ppm NO x
(9,983 Btu/kWh) Fuel System
Low life-cycle cost
• Turbine speed: 7,700 rpm • Natural gas - Liquid fuel - Dual fuel Workshop tested
• Compressor pressure ratio: 14:1 • Fuel-changeover capability at full Excellent operational availability
• Exhaust gas flow: 80.4 kg/s (177.3 lb/s) and part load and reliability
• Exhaust temperature: 543° C (1,009° F) • Gas-supply pressure requirement: Load rejection capability
24.5 bar(a) ±0.5 bar (355±7 psi(a))
• NO x emissions Highly reliable, clean and efficient
(with DLE corrected to 15 % O 2 dry) power generation
Gearbox
- Gas fuel: ≤25 ppmV
- Liquid fuel: ≤42 ppmV (wet) • 50 or 60 Hz Maintenance
On-site maintenance or 24-hour
Axial Compressor Generator
exchange of gas generator
• 10-stage axial flow compressor • Four-pole design No need for special workshop
- 2 stages variable guide vanes • Rated voltage: 10.5/11.0/13.8 kV maintenance
• Electron-beam-welded rotor • 50 or 60 Hz Modular build-up for easy maintenance
• Protection IP54 on site
Combustion • PMG for excitation power supply Standardized concepts for maintenance
• 18 dual-fuel 2nd generation • Complies with -IEC/EN 6034-1 planning
Dry Low Emissions (DLE) burners standard Overhaul intervals of 40,000 hours
• Welded annular sheet metal design Extended time between overhaul when
Lubrication running on part load
Emissions control • Lubricating oil tank located in Condition-based maintenance
• DLE combustion system package base frame Horizontal split compressor casing
• Water injection for NO x -reduction • Two main lube oil circuits, Low deterioration and service cost
during liquid fuel operation in DLE low pressure and high pressure
combustor • 3 x 50 % HP and 3 x 50 % LP AC-driven
lube oil pumps with DC backup
Compressor Turbine
• 2-stage axial-flow compressor turbine Starting
- Both stages are air-cooled • Electric VSD start-motor

Power Turbine Control System


• 2-stage free power turbine, uncooled • Siemens Simatic S7
• Interlocking shrouds • Distributed inputs/outputs
Two multi-unit deliveries of SGT-600 gas turbines power this cement On Torrens Island, Australia, four SGT-600 gas turbines provide seasonal
factory near Riyadh, Saudi Arabia. peaking support for the electrical grid.

Package: Customer Support:


Key features Key features
Compact layout Global support network of Authorized
Low life-cycle cost Service Centers
Short delivery time Emergency service – 24/7 specialist helpdesk
Same footprint as the SGT-700 gas turbine Full field service
Fast and easy installation Full diagnostic support, remote monitoring
Major components delivered on a common base frame OEM modernizations and upgrades
High availability/reliability for complete package In-house or on-site training programs
Range of maintenance and service
contracts available
Height to top of package: 11.9 m

Height: 7.8 m

18.7 m
length:
Wi e package
(dr dth: Gas turbin
ive 4.1
r, g m
en / 4.6
era m
tor
) SGT-600 standard package

1 Combustion air inlet 4 Combustion exhaust 7 Speed reduction gear


2 Enclosure air inlet 5 Enclosure air outlet 8 AC generator
3 Lube oil system 6 Core engine
SGT-600 Performance

Nominal generator output and heat rate


30 11,6
Generator output
Conditions/assumptions:

26 11,4 Fuel: Natural Gas LHV, 46,798 kJ/kg (20,118 Btu/lb)


Altitude: Sea level
Generator output, MW

Ambient pressure: 1,013 bar(a) (14.7 psi(a))

Heat rate, MJ / kWh


22 11,2 Relative humidity: 60 %
Inlet pressure loss: 5 mbar (2” H 2 O
Outlet pressure loss: 5 mbar (2” H 2 O)
18 11
Fuel temperature: 5° C (41° F)

14 10,8
Diagram conversion factors:
Heat rate To convert To Multiply by
° C ° F (° Cx9/5)+32
10 10,6 MJ/kWh Btu/kWh 949
-40 -30 -20 -10 0 10 20 30 40

Compressor inlet air temperature, ° C

Nominal exhaust mass flow and temperature


100 570
Conditions/assumptions:
Exhaust mass flow
90 560 Fuel: Natural Gas LHV, 46,798 kJ/kg (20,118 Btu/lb)
Altitude: Sea level
Ambient pressure: 1,013 bar(a) (14.7 psi(a))
Exhaust temperature, ° C
Exhaust mass flow, kg/s

80 550 Relative humidity: 60 %


Inlet pressure loss: 5 mbar (2” H 2 O)
Outlet pressure loss: 5 mbar (2” H 2 O)
70 540
Fuel temperature: 5° C (41° F)

Exhaust
60 530 Diagram conversion factors:
temperature
To convert To Multiply by
° C ° F (° Cx9/5)+32
50 520

40 510
-40 -30 -20 -10 0 10 20 30 40

Compressor inlet air temperature, ° C

Unfired heat-recovery steam generation


18
Conditions/assumptions:

16 Fuel: Natural Gas LHV, 46,798 kJ/kg (20,118 Btu/lb)


Saturated steam Altitude: Sea level
200° C
Ambient pressure: 1,013 bar(a) (14.7 psi(a))
Steam flow, kg/s

250° C
14 Ambient temperature: 15° C (59° F)
300° C
350° C Relative humidity: 60 %
400° C Boiler pinch point: 8° C (14° F)
12 450° C
500° C
Boiler approach point: 5° C (9° F)
Inlet pressure loss: 5 mbar (2” H 2 O)
10 Outlet pressure loss: 25 mbar (10” H 2 O)

Diagram conversion factors:


8
0 10 20 30 40 50 60 70 80
To convert To Multiply by
° C ° F (° Cx9/5)+32
Steam pressure, bar (a) kg/s lb/s 2.2046
bar psi 14.5

Published by and copyright © 2010: Siemens Energy, Inc. For more information, please contact our All rights reserved. Trademarks mentioned
Siemens AG 10730 Telge Road Customer Support Center. in this document are the property of Siemens AG,
Energy Sector Houston, Texas 77095, USA Tel: +49 180 524 70 00 its affiliates, or their respective owners.
Freyeslebenstrasse 1 Fax: +49 180 524 24 71
Siemens Industrial Turbomachinery AB Subject to change without prior notice.
91058 Erlangen, Germany (Charges depending on provider)
SE-612 83 Finspong, Sweden The information in this document contains
E-mail: support.energy@siemens.com
Siemens AG general descriptions of the technical options
Energy Sector Oil & Gas Division available, which may not apply in all cases.