Note: Led L6 on the LED bar signals the alarms, the buzzer is not used to signal alarms.
Description of operation
When the system registers an alarm/anomaly, led L6 will flash on the panel, while leds L1,..,L5 stay
off. Led L6 will emit a sequence of flashes according to a code below on to identify the faulty
channel and the alarm number. The system detects the alarms for each single channel (maximum
total of 10 alarms at the same time) and displays the first of the recorded alarms on the screen. The
alarm appears on the display until the condition is restored.
Note: When a system alarm occurs, all of the outputs switch off (including WDO).
x Channel Number:
CHANNEL 1 = 3 brief flashes
CHANNEL 2 = 4 brief flashes
PAUSE
Pag. 12
ALARM CODE LIST
Pag. 14
Do not turn the SAR on when the bypass
key is active
Make sure the key-operated selector
Exclusion key input active upon ignition
64 installed on the machine is working
error
correctly
Check the cables
If the error persists, contact assistance
Do not turn the SAR on when you re-arm
movement
Re-arm movements input when lock is Make sure the switch installed on the
65
enabled upon ignition error machine is working correctly
Check the cables
If the error persists, contact assistance
Check the cables
Make sure the internal control unit is
66 Feedback signal reading in frequency error
working correctly
If the error persists, contact assistance
Make sure the external drive is working
External drive 1 feedback signal reading (relay or solenoid)
67
error Check the cables
If the error persists, contact assistance
Make sure the external drive is working
External drive 2 feedback signal reading (relay or solenoid)
68
error Check the cables
If the error persists, contact assistance
Make sure the joystick is operating
Analogue signal from joystick reading correctly
71
error, out of range Check the cables
If the error persists, contact assistance
Make sure the pressure transducer is
Pressure transducer reading error, to check operating correctly
72
joystick re-arming Check the cables
If the error persists, contact assistance
CAN BUS message reception error, in the Check the cables
73
optional external unit If the error persists, contact assistance
Note: Not all the alarms force you to exit the calibration phase.
The alarm error codes that force you to exit the calibration phase are:
- from 11 to 17;
- from 31 to 39;
- from 41 to 49;
- 61.
Release the keys. Turn the system off and
81 Keys pressed upon ignition error then back on again.
If the error persists, contact assistance
Note: The system displays an anomaly, but it is not working (deactivated outputs):
- other alarms may have occurred that block the outputs.