Вы находитесь на странице: 1из 4

VIEW ALARMS ON SAR PANEL



Note: Led L6 on the LED bar signals the alarms, the buzzer is not used to signal alarms.

Description of operation
When the system registers an alarm/anomaly, led L6 will flash on the panel, while leds L1,..,L5 stay
off. Led L6 will emit a sequence of flashes according to a code below on to identify the faulty
channel and the alarm number. The system detects the alarms for each single channel (maximum
total of 10 alarms at the same time) and displays the first of the recorded alarms on the screen. The
alarm appears on the display until the condition is restored.
Note: When a system alarm occurs, all of the outputs switch off (including WDO).

x First sequence of flashes Channel Number


Alarm code sequence

x Second sequence of flashes Alarm Number: 1st DIGIT


x Third sequence of flashes Alarm Number: 2nd DIGIT

HOW TO READ THE ALARM

x Channel Number:
CHANNEL 1 = 3 brief flashes
CHANNEL 2 = 4 brief flashes

x Alarm Number: 1st DIGIT


1,…,9 long flashes

PAUSE

x Alarm number 2nd DIGIT


1,…,9 long flashes

Pag. 12
ALARM CODE LIST

CODE DESCRIPTION WHAT TO DO


CRC error in the memory area that Replace the SAR
11
contains the software If the error persists, contact assistance
Replace the SAR
CRC error in the memory area that
12 Delete and re-run calibration.
contains the parameters
If the error persists, contact assistance
Replace the SAR
13 Programme flow control error
If the error persists, contact assistance
Data exchange error between two Replace the SAR
14
microcontrollers If the error persists, contact assistance
When the machine is off and on, make sure
Supply voltage out of range error
15 that the battery voltage is within the stated
(+7 Vdc ÷ +18 Vdc)
range
Supply voltage out of range inside 1st Replace the SAR
16
channel error (+ 4.8 Vdc ÷ 5.2 Vdc) If the error persists, contact assistance
Supply voltage out of range 2nd channel Replace the SAR
17
error (+ 4.8 Vdc ÷ 5.2 Vdc) If the error persists, contact assistance
Make sure the cables are not damaged
21 Cut Off 1 output status congruency error Replace the SAR
If the error persists, contact assistance
Make sure the cables are not damaged
22 Cut Off 2 output status congruency error Replace the SAR
If the error persists, contact assistance
Make sure the cables are not damaged
23 WDO 1 output status congruency error Replace the SAR
If the error persists, contact assistance
Make sure the cables are not damaged
24 Output 1 status congruency error Replace the SAR
If the error persists, contact assistance
Make sure the cables are not damaged
25 Output 2 status congruency error Replace the SAR
If the error persists, contact assistance
Make sure the cables are not damaged
26 WDO 2 output status congruency error Replace the SAR
If the error persists, contact assistance
Load cell A: Replace the load cell
31
Load sensor internal parameters CRC error If the error persists, contact assistance
Run the calibration test
Load cell A Run calibration again
32 Signal reading out of range error Make sure the cell is clamped on
(10 – 990) Replace the load cell
If the error persists, contact assistance
Load cell A
Replace the load cell
33 Internal offset reading out of range error
If the error persists, contact assistance
(466 – 526)
Load cell A Replace the load cell
34
Internal 5 Vdc supply voltage error If the error persists, contact assistance
Load cell A Replace the load cell
35
No thermal calibration error If the error persists, contact assistance
Pag. 13
Load cell A Replace the load cell
36
Bus LIN message check sum error If the error persists, contact assistance
Replace the load cell
37 Load cell A Sent data CRC error
If the error persists, contact assistance
Check cable integrity
Load cell A
38 Replace the load cell
Bus LIN message reception error
If the error persists, contact assistance
Load cell A Replace the load cell
39
Bus LIN message control meter error If the error persists, contact assistance
Load cell B Replace the load cell
41
Load sensor internal parameters CRC error If the error persists, contact assistance
Run the calibration test
Load cell B Run calibration again
42 Signal reading out of range error Make sure the cell is clamped on
(10 – 990) Replace the load cell
If the error persists, contact assistance
Load cell B
Replace the load cell
43 Internal offset reading out of range error
If the error persists, contact assistance
(526 – 586)
Load cell B Replace the load cell
44
Internal 5Vdc supply voltage error If the error persists, contact assistance
Load cell B Replace the load cell
45
No thermal calibration error If the error persists, contact assistance
Load cell B Replace the load cell
46
Bus LIN message check sum error If the error persists, contact assistance
Load cell B Replace the load cell
47
Sent data CRC error If the error persists, contact assistance
Check cable integrity
Load cell B
48 Replace the load cell
Bus LIN message reception error
If the error persists, contact assistance
Load cell B Replace the load cell
49
Bus LIN message control meter error If the error persists, contact assistance
Difference between load cell A and B
51 Run Calibration Test
readings too great
Difference between the load percentage
52 Run Calibration Test
readings for channels 1 and 2 too great
Make sure the micro switches or
proximities installed on the machine are
Double safety input reading for outriggers
61 working correctly
on the ground congruency error
Check the cables
If the error persists, contact assistance
Make sure the micro switches or
proximities installed on the machine are
Double safety input reading of retracted
62 working correctly
boom congruency error
Check the cables
If the error persists, contact assistance
Make sure the selector installed on the
machine is working correctly
Inputs from mode selector congruency
63 Check the cables
error
If the error persists, contact assistance

Pag. 14
Do not turn the SAR on when the bypass
key is active
Make sure the key-operated selector
Exclusion key input active upon ignition
64 installed on the machine is working
error
correctly
Check the cables
If the error persists, contact assistance
Do not turn the SAR on when you re-arm
movement
Re-arm movements input when lock is Make sure the switch installed on the
65
enabled upon ignition error machine is working correctly
Check the cables
If the error persists, contact assistance
Check the cables
Make sure the internal control unit is
66 Feedback signal reading in frequency error
working correctly
If the error persists, contact assistance
Make sure the external drive is working
External drive 1 feedback signal reading (relay or solenoid)
67
error Check the cables
If the error persists, contact assistance
Make sure the external drive is working
External drive 2 feedback signal reading (relay or solenoid)
68
error Check the cables
If the error persists, contact assistance
Make sure the joystick is operating
Analogue signal from joystick reading correctly
71
error, out of range Check the cables
If the error persists, contact assistance
Make sure the pressure transducer is
Pressure transducer reading error, to check operating correctly
72
joystick re-arming Check the cables
If the error persists, contact assistance
CAN BUS message reception error, in the Check the cables
73
optional external unit If the error persists, contact assistance
Note: Not all the alarms force you to exit the calibration phase.
The alarm error codes that force you to exit the calibration phase are:
- from 11 to 17;
- from 31 to 39;
- from 41 to 49;
- 61.
Release the keys. Turn the system off and
81 Keys pressed upon ignition error then back on again.
If the error persists, contact assistance
Note: The system displays an anomaly, but it is not working (deactivated outputs):
- other alarms may have occurred that block the outputs.

Pag. 15