Вы находитесь на странице: 1из 2

B1 @ Support

steel yields for ρmax:


a= 37.71 cmax= 107.14286
Concrete Compressive Strength,f'c= 20.7 Mpa c= 44.36 a= 91.071429
Tension Steel Reinforcement Yield Strength,fy= 275.0 Mpa fs= 2781.082 As max= 1456.7289
Compression Steel Reinforcement Yield Strength,fy'= 275.0 Mpa εt= 0.013905 ρmax= 0.0233077
reduction factor= 0.9
Beam Width,b= 250 mm Mu= 34.51
Effective Depth,d= 250 mm
Overall Depth,h= 300 mm
steel does not yield
Compression Reinforcement Depth,d'= 50 mm a= 97.34
β1= 0.850 c= 114.52
Tension Reinforcement, As= 603.19 mm2 fs= 709.85
reduction factor= 0.65
Compression Reinforcement, As'= 1005.31 mm2
Mu= 56.03
0.1f'cAg= 155.25 KN =>greater than Pu, εt must be greater than 0.004

INPUT AREA OF REBARS HERE:


As => no.= 3 mm
Ø= 16 mm
Area , As = 603.1858 2
mm
As '=> no. 5 mm
Ø= 16 mm
Area , As '= 1005.31 mm 2

both s teel ba rs yi el d tens i on s teel ba rs not yi el d & compres s i on ba rs yi el d


a= -21.11864 a = 79.318594 0.85fc'β1b= 3738.9375
c= -24.84546 c= 93.315993 As 'fy-0.85fc'As '+600As = 620683.204
fs =-6637.319 fs = 1007.4415 600As d= -90477868
fs '= 1807.464 fs '= 278.5117
εt= -0.033187 εt= 0.0050372
εs'= 0.009037 εs'= 0.0013926
reduction fa ctor, Ø= -2.282216 reduction fa ctor, Ø= 0.65
ØMn= -70.94773 ØMn= 81.342806

εt= 0.0050372
εs'= 0.0013926
reduction fa ctor, Ø= 0.65
ØMn= 81.342806

For Doubly Reinforcement Design:


c= -24.85 mm
Depth of Compres s i on Bl ock, a = -21.12 mm
Check if Tension Bar yield: fs = -6637.32 Mpa =>does not yield, use fs
Check if Compression Bar yield: fs '= 1807.46 Mpa =>yields, use fy'
εt= 0.0050 >0.004 the beam section is adequate as per NSCP 410.4.5
εs'= 0.0014
Reducti on Fa ctor, Ø= 0.65
Moment Ca pa ci ty, ØMn= 81.34 KN-m
steel yields for ρmax:
a= 62.85 cmax= 107.14286
c= 73.94 a= 91.071429
fs= 1428.649 As max= 1456.7289
εt= 0.007143 ρmax= 0.0233077
reduction factor= 0.9
Mu= 54.38

steel does not yield


a= 115.39
c= 135.76
fs= 504.91
reduction factor= 0.65
Mu= 63.45