Вы находитесь на странице: 1из 8

Data Analysis

Simulation developed with 1000 Trajectories


Confidence limit : statistical approach 95% po;ulation
Average inclination of the trajectories α 30.0 o

Tollerance for the barrier inclination β 20.0 o

Trajectory height on the vertical for the 95% of the cases Hv 2.32 m
Trajectory height on the barrier plane (cos (α-β) * Hv) Ht 2.28 m
Minimum distance between barrier and infrastructure Di 6.00 m
Velocity (translational - CI = 95% Vt 21.31 m/s
Size of the Rock St 0.85 m3
Density of the rock W 2500 kg/m3
γt 1.00 (-)
γtr 1.00 (-)
γtg 1.00 (-)
γtw 1.00 (-)
γEN 1.00 (-)
γDB 1.00 (-)

Barrier Design - No Safety Factor


Design trajectory velocity (Vt * γt * γtr) Vd 21.31 m/s
Design trajectory mass (St * γtg * W * γtw) Md 2125 kg
Design trajectory height (Ht * γt * γtr + Boulder raidus) Hd 2.87 m/s
Design trajectory energy (0.5 * Md * Vd 2) Ed 482.50 kJ
Design Energy (EBTE / (γEN * i)) E 482 kJ
Design Elongation (Db * γDB) D 6.00 m
Design height barrier (Hb - Fb) H 2.9 m
Energy Proof (Ed - E ≤ 0) Ed - E 0.0 FULFILLED
Elongation Proof (D - Di ≤ 0) D - Di 0.0 FULFILLED
Height Proof (Hd - H ≤ 0) Hd - H 0.0 FULFILLED

Barrier Design - With Safety Factors


Quality of topographic survey γt 1.07 (-)
Quality of Geomechanical survey - size γtg 1.10 (-)
Quality of Geomechanical survey - density γtw 1.05 (-)
Quality of rock simulation γtr 1.07 (-)
Design trajectory velocity (Vt * γt * γtr) Vd 24.40 m/s
Design trajectory mass (St * γtg * W * γtw) Md 2454 kg
Design trajectory height (Ht * γt * γtr + Boulder raidus) Hd 3.20 m/s
Design trajectory energy (0.5 * Md * Vd 2) Ed 730.49 kJ
Specification of Flexible Barrier
Maximum energy MEL 1076 kJ
Service energy level SEL 358.67 kJ
Maximum dynamic elongation MEL Db 3.5 m
Nominal height of the barrier Hb 4 m
Upper free border for the design boulder Fb 0.2 m
Design Method MEL
Maximum Energy Level EBTE 1076 kJ
I factor i 1
Safety factor for reduction of the barrier energy γEN 1.20 (-)
Safety factor for the deformation γDB 1.30 (-)
Design Energy (EBTE / (γEN * i)) E 897 kJ
Design Elongation (Db * γDB) D 4.55 m
Design height barrier (Hb - Fb) H 3.3 m
Energy Proof (Ed - E ≤ 0) Ed - E -166.2 FULFILLED
Elongation Proof (D - Di ≤ 0) D - Di -1.5 FULFILLED
Height Proof (Hd - H ≤ 0) Hd - H -0.1 FULFILLED
Trajectories
Data Analysis
Simulation developed with 1000 Trajectories
Confidence limit : statistical approach 95% po;ulation
Average inclination of the trajectories α 75.0 o

Tollerance for the barrier inclination β 20.0 o

Trajectory height on the vertical for the 95% of the cases Hv 3.3 m
Trajectory height on the barrier plane (cos (α-β) * Hv) Ht 1.89 m
Minimum distance between barrier and infrastructure Di 5.00 m
Velocity (translational - CI = 95% Vt 21.4 m/s
Size of the Rock St 0.75 m3
Density of the rock W 2500 kg/m3
γt 1.00 (-)
γtr 1.00 (-)
γtg 1.00 (-)
γtw 1.00 (-)
γEN 1.00 (-)
γDB 1.00 (-)

Barrier Design - No Safety Factor


Design trajectory velocity (Vt * γt * γtr) Vd 21.40 m/s
Design trajectory mass (St * γtg * W * γtw) Md 1875 kg
Design trajectory height (Ht * γt * γtr + Boulder raidus) Hd 2.46 m/s
Design trajectory energy (0.5 * Md * Vd 2) Ed 429.34 kJ
Design Energy (EBTE / (γEN * i)) E 429 kJ
Design Elongation (Db * γDB) D 5.00 m
Design height barrier (Hb - Fb) H 2.5 m
Energy Proof (Ed - E ≤ 0) Ed - E 0.0 FULFILLED
Elongation Proof (D - Di ≤ 0) D - Di 0.0 FULFILLED
Height Proof (Hd - H ≤ 0) Hd - H 0.0 FULFILLED

Barrier Design - With Safety Factors


Quality of topographic survey γt 1.02 (-)
Quality of Geomechanical survey - size γtg 1.02 (-)
Quality of Geomechanical survey - density γtw 1.02 (-)
Quality of rock simulation γtr 1.02 (-)
Design trajectory velocity (Vt * γt * γtr) Vd 22.26 m/s
Design trajectory mass (St * γtg * W * γtw) Md 1951 kg
Design trajectory height (Ht * γt * γtr + Boulder raidus) Hd 2.53 m/s
Design trajectory energy (0.5 * Md * Vd 2) Ed 483.50 kJ
Specification of Flexible Barrier
Maximum energy MEL 500 kJ
Service energy level SEL 170 kJ
Maximum dynamic elongation MEL Db 3.5 m
Nominal height of the barrier Hb 4 m
Upper free border for the design boulder Fb 0.2 m
Design Method MEL
Maximum Energy Level EBTE 500 kJ
I factor i 1
Safety factor for reduction of the barrier energy γEN 1.20 (-)
Safety factor for the deformation γDB 1.30 (-)
Design Energy (EBTE / (γEN * i)) E 417 kJ
Design Elongation (Db * γDB) D 4.55 m
Design height barrier (Hb - Fb) H 3.3 m
Energy Proof (Ed - E ≤ 0) Ed - E 66.8 NOT OK
Elongation Proof (D - Di ≤ 0) D - Di -0.5 FULFILLED
Height Proof (Hd - H ≤ 0) Hd - H -0.8 FULFILLED