NG06 NG10
Features
• Proportional adjustment
• Manifold mounting acc. to ISO5871
• External drain
• Main stage spool type valve
• Pilot stage seated type valve
4
NG06 NG10
NG06 NG10
Ordering code
V B Y K
VBY_K.PMD RH
Technical data
General
Design type Proportional pressure valve
Nominal size NG06 NG10
Interface ISO 5871
Actuation Proportional solenoid
Mounting position as desired
Ambient temperature [°C] -20 ... +70
Weight [kg] 5
Hydraulics
Operating pressure [bar] Ports P and A 315; Port T depressurized Ports A and B 315; Port Y depressurized
Nominal flow [l/min] 40 160
Adjustment range [bar] up to 64, 100, 160, 210, 315
Pressure medium Hydraulic oil as per DIN 51 524 ... 525
Viscosity, recommended [mm²/s] 30 ... 50
maximum [mm²/s] 20 ... 380
Pressure medium temperature
recommended [°C] 30 ... 50
maximum [°C] -20 ... +70
4 Permitted contamination
Linearity [%]
ISO 4406 (1999); 18/16/13
±3.5 at > 15% pnom.
Repeatability [%] <±2
Hysteresis [%] ±1.5 to pmax
Response time [ms] <150 <200
Manufacturing tolerance [%] ±5 to pmax
Electrical
Duty cycle [%] 100 ED
Protection class IP54 at DIN 40050 (plugged and mounted)
Nominal voltage [VDC] 12
Max. current [A] 2.7
Ambient temperature [°C] -20...+70
Coil resistance [Ohm] 21 at 20°C
Plug connectors 2pole + PE / connector EN 175301-803 / cableØ 8...10mm
Power amplifier PCD00A-400
VBY_K.PMD RH
Setting range max. 160 bar Setting range max. 210 bar
VBY_K.PMD RH
Setting range max. 160 bar Setting range max. 210 bar
VBY_K.PMD RH
NG06
The connection B
must be locked
onto the subplate
for standard appli-
cations.
VBY_K.PMD RH
NG10
BK-M10x50-4pcs 65 Nm SK-VB/VM-A10V
VBY_K.PMD RH