Catalogue HY11-2500/UK Pilot-Operated Sequence Valve

Characteristics / Ordering Code Series VBY*K

Pilot-operated sequence valve with proportional adjust-


ment. Series VBY*K is a pilot-operated pressure valve
with external drain. The external drain allows an applica-
tion as sequence and as pressure relief valve. For usage
as a pressure relief valve observe hydraulic connection.

NG06 NG10
Features
• Proportional adjustment
• Manifold mounting acc. to ISO5871
• External drain
• Main stage spool type valve
• Pilot stage seated type valve

4
NG06 NG10

NG06 NG10

Ordering code

V B Y K

Sequence Max. Linear Nominal Seal Design


valve setting solenoid size series
range 12 VDC
2.7 A
Code Max. setting range Code Seal
064 64bar N NBR
100 100bar V FPM
160 160bar
210 210bar Code Nominal size
315 315bar
06 NG06
10 NG10

VBY_K.PMD RH

4-89 Parker Hannifin GmbH & Co. KG


Hydraulic Controls Division
Kaarst, Germany
Catalogue HY11-2500/UK Pilot-Operated Sequence Valve
Technical Data / Characteristic Curves Series VBY*K

Technical data
General
Design type Proportional pressure valve
Nominal size NG06 NG10
Interface ISO 5871
Actuation Proportional solenoid
Mounting position as desired
Ambient temperature [°C] -20 ... +70
Weight [kg] 5
Hydraulics
Operating pressure [bar] Ports P and A 315; Port T depressurized Ports A and B 315; Port Y depressurized
Nominal flow [l/min] 40 160
Adjustment range [bar] up to 64, 100, 160, 210, 315
Pressure medium Hydraulic oil as per DIN 51 524 ... 525
Viscosity, recommended [mm²/s] 30 ... 50
maximum [mm²/s] 20 ... 380
Pressure medium temperature
recommended [°C] 30 ... 50
maximum [°C] -20 ... +70

4 Permitted contamination
Linearity [%]
ISO 4406 (1999); 18/16/13
±3.5 at > 15% pnom.
Repeatability [%] <±2
Hysteresis [%] ±1.5 to pmax
Response time [ms] <150 <200
Manufacturing tolerance [%] ±5 to pmax
Electrical
Duty cycle [%] 100 ED
Protection class IP54 at DIN 40050 (plugged and mounted)
Nominal voltage [VDC] 12
Max. current [A] 2.7
Ambient temperature [°C] -20...+70
Coil resistance [Ohm] 21 at 20°C
Plug connectors 2pole + PE / connector EN 175301-803 / cableØ 8...10mm
Power amplifier PCD00A-400

Characteristic pressure curves for NG06 p = f (Uset)


Setting range max. 64 bar Setting range max. 210 bar

VBY_K.PMD RH

4-90 Parker Hannifin GmbH & Co. KG


Hydraulic Controls Division
Kaarst, Germany
Catalogue HY11-2500/UK Pilot-Operated Sequence Valve
Characteristic Curves Series VBY*K

p/Q characteristics VBY*K NG06


measured at t = 50°C and ν = 35 mm²/s

Setting range max. 64 bar Setting range max. 100 bar

Setting range max. 160 bar Setting range max. 210 bar

Setting range max. 315 bar

VBY_K.PMD RH

4-91 Parker Hannifin GmbH & Co. KG


Hydraulic Controls Division
Kaarst, Germany
Catalogue HY11-2500/UK Pilot-Operated Sequence Valve
Characteristic Curves Series VBY*K

Step response signal VBY*K NG06


Setting range max. 210 bar

p/Q characteristics VBY*K NG10


measured at t = 50°C and ν = 35 mm²/s

Setting range max. 64 bar Setting range max. 100 bar

Setting range max. 160 bar Setting range max. 210 bar

VBY_K.PMD RH

4-92 Parker Hannifin GmbH & Co. KG


Hydraulic Controls Division
Kaarst, Germany
Catalogue HY11-2500/UK Pilot-Operated Sequence Valve
Dimensions Series VBY*K

NG06

Surface finish Bolt kit DIN912 12.9


NBR FPM

BK-M5x30-4pcs 7.5 Nm SK-VMY-L06-N SK-VMY-L06-V

Mounting pattern ISO 5781-03-04-0-00

The connection B
must be locked
onto the subplate
for standard appli-
cations.

VBY_K.PMD RH

4-93 Parker Hannifin GmbH & Co. KG


Hydraulic Controls Division
Kaarst, Germany
Catalogue HY11-2500/UK Pilot-Operated Sequence Valve
Dimensions Series VBY*K

NG10

Surface finish Bolt kit DIN912 12.9 FPM

BK-M10x50-4pcs 65 Nm SK-VB/VM-A10V

Mounting pattern ISO 5781-06-07-0-00

VBY_K.PMD RH

4-94 Parker Hannifin GmbH & Co. KG


Hydraulic Controls Division
Kaarst, Germany