1) Select the lightest W-section for beam-column subjected to service design loads as shown
below. The member is part of a braced building frame and has support in the weak direction at
mid-height; and only at top and bottom for the strong direction. These supports are to be
assumed as hinged. Sections are made of A-36 steel Fy 250 MPa .
P 130 kN P 130 kN
2.4 m
2.4 m
Cross-beam
H 30 kN
0.2 f a
2.4 m Cm 1.0 2.4 m
Fex|
For buckling For buckling
in x-direction in y-direction
2) Select the lightest W-section for beam-column shown below subjected to a service design axial
compression in addition to service design biaxial bending moments in both directions.
Sections are made of A-36 steel Fy 250 MPa .
P 250 kN P 250 kN
M x 35 kN m M y 8kN m
M x 35 kN m M y 8 kN m
2.5 m
Cross-beam
2kN-m
2.5 m
3) Redesign steel column base-plate for the same steel column given in exercise-problem made of
W-360x110 to transfer a service design load moment of 265kN-m in addition to axial-
compressive load of 1670kN to concrete footing. Use the same data given in exercise-problem.