Вы находитесь на странице: 1из 3

DESIGN OF PIPE CULVERT (Double Lane)

1 ) Hydraulic Particulars :-

Sl.
Description Unit Particulars
No.

1 Discharge (Required/Designed) Cumecs 0.0760 / 0.0814

2 Bed width m 0.500

3 Full Supply Depth m 0.300

4 Free board m 0.300

5 C.B.L. m + 443.805

6 F.S.L. m + 444.105

7 T.B.L. m + 444.405

8 G.L. m + 445.430

9 R.L. m + 445.430

2 ) VENTWAY

Area required by assuming 2 X V = 0.0814 = 0.143 m2


0.5710
Area of ventway D = 0.30 = 0.750
d 0.400
For D/d ca = 0.6320
Provide two rows of 400 Φ pipe
A = Ca d^2
= 0.2022 m2
Velocity = 0.4025 m/sec < twice the Normal velocity 0.571

3 ) Details of PIPE
Dia of the Pipe = 400 mm
Class of the pipe = NP3
Thickness of pipe = 75 mm
Length of Collor = 150 mm
Thickness of collor 32 mm
Caulking space 16 mm

4 ) Road Level

XIV - 1
Top of pipe = = + 443.805 + 0.400 + 0.075
= 444.280 m
Thickness of CC Slab + WC = 0.300 + 0.075 = 0.375 m
R.L = 444.655 m < + 445.430 G.L
provide RL = 445.430 m
Carraige way available =
3 Pipes in one row 2.5 m Length = 3 x 2.5 - 2x0.375 = 6.750 m
5) DESIGN OF HEAD WALLS
Head walls in C.C M15 using 40 MSA well graded
1 Top Width of wall 0.450 m
2 Foundation in VCC M10 using 40 MSA 0.450 m
3 Foundation off set 0.150 m
4 Type of Road METAL ROAD
5 Below R.L slab in VCC M20 0.300 m thick

XIV - 2
Annexure - XIV

m/sec

XIV - 3