Вы находитесь на странице: 1из 35

DWG Number 119T3740 REV C Released 2016/11/23 Page 1 of 69

Project

ACONCAGUA Cogeneration Project


1xGT-6F.03
Concon (CHILE)
Customer

DURO FELGUERA S.A.

DF Client Code Number : ACP-DFE-11-MB_-EE-50013


End user

Empresa Nacional del Petroleo (ENAP)

REFERENCE NUMBER :943329 0414 -- EEC 0001 REVISION : 3


ECH / SCALE DATE (YYYY-MM-DD) 2016/11/15 2016/11/22 2016/11/23
None NOM / NAME Lim,Sorya Rousselet,Rodolphe Masson,Christophe
FORMAT / SIZE VISA Lim,Sorya Rousselet,Rodolphe Masson,Christophe
A4 REDIGE / MADE VERIFIE / CHECKED APPROUVE / APPROVED

TITRE / TITLE
MECHANICAL GENERAL
GT DEVICE SUMMARY

Duro Felguera : Garcia F. Javier; Iglesias


Isabel; Moratinos Ignacio; dt.dfe
FOR INFORMATION
aconcagua;
GE : Parashar Deepak;

Ce document, propriété exclusive de REVISION


GE Energy Products France SNC
est strictement confidentiel. Il ne peut
être communiqué, copié ou reproduit
sans son autorisation écrite préalable
GE Energy C
INSTRUCTION DE
MODIFICATION

This document, exclusive property of ECO0274653


GE Energy Products France SNC N° 119T3740 Section Doc.
is strictly confidential. It must not be
communicated, copied or reproduced
without our previous written consent. SHEET. N°
GRD

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 2 of 69
SIZE DWG NO SH REV
A4 119T3740 1 C TBFT-TMP-FR-GTE-0060- Rev : 001

ISO PROJECTION REVISIONS


REV DESCRIPTION NAMES DATE SIGNATURES
J.M. Bardine
- First issue R. Rousselet 02/11/2015
M. Lefoll
EACH SECTION SHALL BE REVISED IN AE&OS
ITS ENTIRETY. A ECO0230325 R. Rousselet 29/01/2016
ALL SHEETS OF EACH SECTION ARE M. Lefoll
THE SAME REVISION LEVEL AS
AE&OS
INDICATED IN THE REVISION
BLOCK
B ECO0253143 R. Rousselet 06/06/2016
C. Masson
SECTION NO. OF REV AE&OS
SHEETS C ECO0274653 R. Rousselet 15/11/2016
INDEX 1 C C. Masson
01EN 34 C
01FR 35 C

Attention: Don’t modify this document without any update of the database P414.

Attention : Ne pas modifier ce document sans mise à jour de la base P414.

Ce document, propriété exclusive de


GE Energy Products France SNC est strictement confidentiel. Il ne
peut être communiqué, copié ou
reproduit sans notre autorisation écrite préalable.

This document, exclusive property of


GE Energy Products France SNC is strictly confidential.
It must not be communicated, copied or
reproduced without our prior written consent. First made for : 6111FA ITEM : 0414
UNLESS OTHERWISE SPECIFIED NAMES DATE
DIMENSIONS ARE IN MM [INCHES] DRAWN 02/11/15
J.M. Bardine
TOLERANCES ON:
CHECKED 02/11/15
1 [2] PL DECIMALS + R. Rousselet
APPROVED 02/11/15
2 [3] PL DECIMALS + M. Lefoll NOMENCLATURE DES APPAREILS DE CONTROLE
ANGLES +
DIAGRAM. SCHEMA. P.P. – DEVICE SUMMARY
FRACTIONS +
WEIGHT : 0000 kg SIZE CAGE CODE DWG NO
A4 119T3740 INDEX
SCALE SHEET 1/1
Doc. Source : TBFT-ISP-FR-GTE-0020

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 3 of 69
SIZE DWG NO SH REV
A4 119T3740 1 C TBFT-TMP-FR-GTE-0060 Rev : 001

REVISIONS

Rev Description

- First issue
- MLI PID 0403 : added ASW-211, ASW-212, ASW-213, ASW-214, AR-211, AR-212, AR-213, AR-214, AL-
211, AL-212, AL-213, AL-214, AL-215v6, AL-217, AL-218, AL-219, AL-220, AL-221, AL-222, DL-211, DL-
212, DL-213, DL-214, DL-215, DL-216, DL-217, DL-218
- MLI PID 0436 : added 33GV-1, 33GV-2, 26GV-5, 23GV-3, AT-GC-1, 88GV-1, 88GV-2, DV350, DV351, F-
A
GV-1, F-GV-2
- MLI PID 0471 : added 20AF-1A, 20AF-1B, 20AF-1C, 23AF-1A, 23AF-1B, 23AF-1C, 33AG-1A, 33AG-1B,
33AG-1C, 63TF-2A, 63TF-2B, 96HW-1, 96RH-1, 96TF-1, 96TF-3, 96TF-4, AT-ID-1, AT-ID-2, AT-ID-3, AT-
ID-4, AT-ID-5, AT-ID-6
- MLI PID 0417 : device deleted 63BN-1, 63BN-2, 63TK-1, 63TK-2
- MLI PID 0417 : device added 96BN-1, 96BN-2, 96TK-1, 96TK-2
B
- MLI PID 0471 : device deleted 63TF-2A, 63TF-2B
- MLI PID 0471 : device added 96TF-2A, 96TF-2B
C - MLI PID 0442 : device added VA17-7

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 1/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 4 of 69
SIZE DWG NO SH REV
A4 119T3740 2 C TBFT-TMP-FR-GTE-0060 Rev : 001

PRESSURE : All pressures are gauge pressure, abs means absolute pressure.

Abbreviations Descriptions
AA Atomizing Air
ACF Control Filter Downstream Pressure
AD Compressor Discharge Air
AE Extraction Air
AMF Lube Oil Filter Downstream Pressure
DEC. Decreasing
DPDT Double pole, double throw
DPG Differential Pressure Gauge
FC Fail safe to close
FO Fail open
GF Gas Fuel
GFV Gas Fuel Vent
GPL Gas Valve Stem Packaging Leakoff
INC. Increasing
LVDT Linear variable differential transformer
Model List Item : four digit code used by General Electric to identify
MLI components, assembly, drawings or specifications, example : MLI 0414 for
Device Summary
NC Normally closed
NO Normally open
Means absolute zero energy level, such as no power, no oil, no speed, no
Normal
temperature
OD Oil Drain
OD
Oil drain above oil tank level

OD
Oil drain below oil tank level

OH Control Oil High Pressure


OHT Trip Oil High Pressure
OL Lube Oil
OLV Lube Oil Event
OR Regulated Lube Oil
PC Piping connecting point
A cross in the column means the device belongs to a safety loop related to
Safety
human safety. Do not modify devices or settings of any safety loop.
Slope The arrow direction indicates the liquid gravitational drainage due to the slope
SPDT Single pole, double throw
SPST Single pole, single throw
WD Water Drain
WF Water Feed
WR Water Return

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 2/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 5 of 69
SIZE DWG NO SH REV
A4 119T3740 3 C TBFT-TMP-FR-GTE-0060 Rev : 001

Wiring diagram Description


ACCY The device is in the accessories wiring diagram (MLI 401A)
AIR The device is in the cooling fan module wiring diagram (MLI A132)
AIR DRY The device is in the air dryer module wiring diagram (MLI 1049)
CHROM The device is in the chromatograph module wiring diagram (MLI G023)
CLEAN The device is in the cleaning module wiring diagram (MLI E026)
CO2 The device is in the CO2 fire protection module wiring diagram (MLI A068)
ENCL-G The device is in the gas enclosure interface drawing (MLI 1195)
The device is in the liquid fuel / atomizing air / water injection module enclosure interface drawing (MLI
ENCL-LF
1152)
ENCL-LO The device is in the lube oil / fuel gas module enclosure interface drawing (MLI 1137)
ENCL-T The device is in the turbine enclosure interface drawing (MLI 1113)
ENCL-V The device is in the ventilation enclosure interface drawing (MLI 1643)
ENCL-WI The device is in the water injection enclosure interface drawing (MLI 1196)
FILT The device is in the air filter wiring diagram (MLI A040)
FG-SSOV The device is in the fuel gas, SSOV & vent module wiring diagram (MLI G064)
GAS The device is in the gas module wiring diagram (MLI 0991, A116 or 401G)
GAS HEAT The device is in the gas heating and treatment system wiring diagram (MLI G025)
GENE The device is in the generator wiring diagram
HEAT TR The device is in the interconnection pipes wiring diagram (MLI 0969)
IBH The device is in the bleed heating wiring diagram (MLI A037)
LF-AA The device is in the liquid fuel / atomizing air module wiring diagram (MLI A162)
LF-AA-WI The device is in the liquid fuel / atomizing air / water injection module wiring diagram (MLI A162)
LF-SR The device is in the liquid fuel recirculation skid wiring diagram (MLI 969S)
LF-TR The device is in the liquid fuel treatment skid wiring diagram (MLI E020)
LF-FD The device is in the liquid fuel flow devider wiring diagram (MLI 0613)
LF-H The device is in the liquid fuel heater wiring diagram (MLI E041)
LF-TPH The device is in the liquid fuel transfert pump&heating skid wiring diagram (MLI E047)
LF-PH The device is in the liquid fuel pump&heating skid wiring diagram (MLI A245)
LF-FT-PR The device is in the liquid fuel flow totalizer & pression regulation skid wiring diagram (MLI A246)
LO FG The device is in the lube oil / fuel gas module wiring diagram (MLI A160)
LOAD The device is in the load gear wiring diagram (MLI A012)
MIST The device is in the mist eliminator outline drawing (MLI A098)
OIL The device is in the lube oil wiring diagram (MLI 0990 or 401H)
STEAM The device is in the steam injection module wiring diagram (MLI A135)
TURB The device is in the gas turbine wiring diagram (MLI 401T)

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 3/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 6 of 69
SIZE DWG NO SH REV
A4 119T3740 4 C TBFT-TMP-FR-GTE-0060 Rev : 001

TURN-GEAR The device is in the turning gear wiring diagram (MLI A073)
VAN The device is in the additive injection vanadium module wiring diagram (MLI E021)
WASH The device is in the water washing module wiring diagram (MLI E025)
WI The device is in the water injection module wiring diagram (MLI A035)

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 4/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 7 of 69
SIZE DWG NO SH REV
A4 119T3740 5 C TBFT-TMP-FR-GTE-0060 Rev : 001

MLI
System Name System Reference Rev
P&ID
Electrical Enclosure Equipment System 0403 0403 118T5655 -
Control Devices Turbine System 0415 CD 118T4003 -
Lube Oil System 0416 LO 118T3828 -
Cooling and Sealing Air System 0417 CSA 118T3675 -
Trip Oil System 0418 TO 118T3830 -
Instrument Air System 0419 APU N/A
Cooling Water System 0420 CW 118T3707 -
Gas Fuel System 0422 GF 118T4549 -
Liquid Fuel System 0424 LF N/A
Atomizing Air System 0425 AA N/A
Fire Protection System 0426 FP 118T6797 -
Air Extraction System 0428 AE N/A
Steam Injection System 0431 SI N/A
Inlet Air heating System 0432 IAR 118T3676 -
Hydraulic Supply System 0434 HS 118T3829 -
Heating and Ventilation System 0436 HV 118T6796 -
Turbine and Compressor Cleaning System 0441 TCC N/A
Turbine and Compressor Washing System 0442 TCW 118T3708 -
Water Injection System 0462 WI N/A
Compressor Inlet Guide Vanes System 0469 IGV 118T3831 -
Inlet and Exhaust System 0471 IE HOLD -
Gas Detection System 0474 GD 118T6798 -
Fuel Purge System 0477 FPU N/A
Performance Monitor System 0492 PM 118T4014 -
Load Gear System 0495 LG 118T4646 -
Interconnections Lines System 0969 IL N/A

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 5/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 8 of 69
SIZE DWG NO SH REV
A4 119T3740 6 C TBFT-TMP-FR-GTE-0060 Rev : 001

MLI Wiring
Devices KKS DEVICE MLI Safety Designation
PID Diagram
Check valve downstream DI101
0418 0418-VCK100 MBV40AA001 A160 N/A
Characteristics : Normal : NC
Instrumentation air filter for inlet air heating control valve (VA20-1)
0432 0432-FA041 MBL70AT041 A037 N/A
Characteristics : 40 µm
0474 0474-DE101 CYQ10BN001 0585 N/A Discharge ejector after IA50
0474 0474-DE103 CYQ10BN003 0585 N/A Discharge ejector after IA52
0474 0474-DE105 CYQ11BN001 0585 N/A Discharge ejector after IA54
0474 0474-HV101 CYQ10AA001 0585 N/A 3 way valve after filter FAGD-1
0474 0474-HV102 CYQ10AA002 0585 N/A 3 way valve after filter FAGD-2
0474 0474-HV104 CYQ10AA004 0585 N/A 3 way valve after filter FAGD-4
0474 0474-HV105 CYQ10AA005 0585 N/A 3 way valve after filter FAGD-5
0474 0474-HV108 CYQ11AA001 0585 N/A 3 way valve after filter FAGD-8
0474 0474-HV109 CYQ11AA002 0585 N/A 3 way valve after filter FAGD-9
Electromagnet
0471 20AF-1A MBL20AA401A A040 FILT
Characteristics : Normal : NC | 3.6 W | 24 VDC
Electromagnet
0471 20AF-1B MBL20AA401B A040 FILT
Characteristics : Normal : NC | 3.6 W | 24 VDC
Electromagnet
0471 20AF-1C MBL20AA401C A040 FILT
Characteristics : Normal : NC | 3.6 W | 24 VDC
Compressor bleed solenoid valve
0417 20CB-1 MBH27AA201A 1071 TURB
Characteristics : Normal : B to C Open, A closed | 0.04 kW | 125 VDC
Compressor bleed solenoid valve
0417 20CB-2 MBH26AA201A 1071 TURB
Characteristics : Normal : B to C Open, A closed | 0.04 kW | 125 VDC
Fuel gas stop valve solenoid valve
0418 20FG-1 MBV40AA402 1019 LO FG
Characteristics : Normal : NO | 0.1 kW | 125 VDC
Trip solenoid valve bleed heating control valve
0432 20TH-1 MBL70AA202A A037 IBH
Characteristics : Normal : 1 to 3 open | 0.0112 kW | 125 VDC


Solenoid valve for compressor IGV trip system
0418 20TV-1 MBV40AA401 1019 TURB
Characteristics : Normal : NO | 0.1 kW | 125 VDC
Off-line compressor water wash solenoid valve
Characteristics :
0442 20TW-4 MBU33AA201A 0953 TURB
De-energized : 1 to 3 open; 2 closed
Energized : 2 to 1 open; 3 closed | 0.12 kW | 230 VAC | 50 Hz
On-line compressor water wash solenoid valve
Characteristics :
0442 20TW-6 MBU33AA202A 0953 TURB
De-energized : 1 to 3 open; 2 closed
Energized : 2 to 1 open; 3 closed | 0.12 kW | 230 VAC | 50 Hz


Fuel gas vent solenoid valve
0422 20VG-1 MBP70AA230A A160 LO FG
Characteristics : Normal : FO | 0.009 kW | 125 VDC


Fuel gas vent solenoid valve
0422 20VG-8 MBP68AA220A G064 FG-SSOV
Characteristics : Normal : FO | 0.0106 kW | 125 VDC
Vent solenoid valve allowing the VGV-10 supply
0422 20VGV-10 MBP70AA290A A160 LO FG
Characteristics : Normal : FO | 0.0106 kW | 125 VDC


Gas stop valve VS4-4 solenoid valve
0422 20VS4-4 MBP68AA210A G064 FG-SSOV
Characteristics : Normal : FO | 0.0046 kW | 125 VDC
By-pass flap heat tracing
0471 23AF-1A MBL20AH001A A040 FILT
Characteristics : 0.125 kW | 50 Hz | 230 VAC
By-pass flap heat tracing
0471 23AF-1B MBL20AH001B A040 FILT
Characteristics : 0.125 kW | 50 Hz | 230 VAC

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 6/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 9 of 69
SIZE DWG NO SH REV
A4 119T3740 7 C TBFT-TMP-FR-GTE-0060 Rev : 001

MLI Wiring
Devices KKS DEVICE MLI Safety Designation
PID Diagram
By-pass flap heat tracing
0471 23AF-1C MBL20AH001C A040 FILT
Characteristics : 0.125 kW | 50 Hz | 230 VAC
Lube oil compartment air inlet heater
0436 23BL-1 SAE40AH011 1634 ENCL-LO
Characteristics : 50 Hz | 380 VAC | 15 kW
Anti-condensation heater for motor 88BN-1
0417 23BN-1 MBH15AN001-R01 A132 AIR
Characteristics : 50 Hz | 220 VAC | 0.05 kW
Anti-condensation heater for motor 88BN-2
0417 23BN-2 MBH15AN002-R01 A132 AIR
Characteristics : 50 Hz | 220 VAC | 0.05 kW
Anti-condensation heater for motor 88BT-1
0436 23BT-1 SAE27AN001-R01 1605 ENCL-T
Characteristics : 50 Hz | 220 VAC | 0.08 kW
Anti-condensation heater for motor 88BT-2
0436 23BT-2 SAE28AN001-R01 1605 ENCL-T
Characteristics : 50 Hz | 220 VAC | 0.08 kW
Lube oil compartment heater
0436 23HL-30 SAE40AH001 1137 ENCL-LO
Characteristics : 50 Hz | 380 VAC | 9 kW
Anti-condensation heater for motor 88HQ-1
0434 23HQ-1 MBX11AP001-R01 0627 LO FG
Characteristics : 50 Hz | 230 VAC | 0.05 kW
Anti-condensation heater for motor 88HQ-2
0434 23HQ-2 MBX12AP001-R01 0627 LO FG
Characteristics : 50 Hz | 230 VAC | 0.05 kW
Turbine compartment heater
0436 23HT-30 SAE20AH005 1113 ENCL-T
Characteristics : 50 Hz | 380 VAC | 20 kW
Anti-condensation heater for motor 88QA-1
0416 23QA-1 MBV20AP001-R01 1005 LO FG
Characteristics : 50 Hz | 230 VAC | 0.05 kW
Anti-condensation heater for motor 88QA-2
0416 23QA-2 MBV20AP002-R01 1006 LO FG
Characteristics : 50 Hz | 230 VAC | 0.05 kW
Immersion heater lube oil tank
0416 23QT-1 MBV10AH003 A160 LO FG
Characteristics : 50 Hz | 380 VAC | 6 kW
Immersion heater lube oil tank
0416 23QT-2 MBV10AH004 A160 LO FG
Characteristics : 50 Hz | 380 VAC | 6 kW
Immersion heater lube oil tank
0416 23QT-3 MBV10AH005 A160 LO FG
Characteristics : 50 Hz | 380 VAC | 6 kW
Immersion heater lube oil tank
0416 23QT-4 MBV10AH006 A160 LO FG
Characteristics : 50 Hz | 380 VAC | 6 kW
Anti-condensation heater for motor 88QV-1A
0416 23QV-1A MBV11AN001-R01 A098 LO FG
Characteristics : 50 Hz | 230 VAC | 0.05 kW
Anti-condensation heater for motor 88QV-1B
0416 23QV-1B MBV11AN002-R01 A098 LO FG
Characteristics : 50 Hz | 230 VAC | 0.05 kW
88TG-1 motor space heater
0495 23TG-1 MBJ20AE001-R01 A073 LOAD
Characteristics : 50 Hz | 230 VAC | 0.05 kW
Anti-condensation heater for motor 88TK-1
0417 23TK-1 MBH10AN001-R01 A132 AIR
Characteristics : 50 Hz | 230 VAC | 0.05 kW
Anti-condensation heater for motor 88TK-2
0417 23TK-2 MBH10AN002-R01 A132 AIR
Characteristics : 50 Hz | 230 VAC | 0.05 kW
Load gear compartment heater
0436 23VA-30 SAE10AH001 1113 ENCL-T
Characteristics : 50 Hz | 380 VAC | 9 kW
Gas compartment heater
0436 23VL-1 SAE70AH015 1137 ENCL-LO
Characteristics : 50 Hz | 380 VAC | 3.9 kW
Gas compartment air inlet heater
0436 23VL-2 SAE70AH016 1634 ENCL-LO
Characteristics : 50 Hz | 380 VAC | 15 kW

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 7/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 10 of 69
SIZE DWG NO SH REV
A4 119T3740 8 C TBFT-TMP-FR-GTE-0060 Rev : 001

MLI Wiring
Devices KKS DEVICE MLI Safety Designation
PID Diagram
Security thermostat of the generator compartment heater
0436 26GV-5 SAF10CT301 1113 ENCL-T Characteristics : Normal : NC
Settings : Opened at NC °C
Generator compartment heater
0436 23GV-5 SAF10AH001 1113 ENCL-T
Characteristics : 50 Hz | 380 VAC | 12kW
0471 27TF-1 MBL20GS001-K01 A040 FILT GT air filter general alarm dispatching
0415 28FD-1 MBM12CQ009 1121 TURB  Flame detector, 2nd zone of chamber combustion n°1
0415 28FD-2 MBM12CQ010 1121 TURB  Flame detector in combustion chamber n°2
0415 28FD-6A MBM12CQ013 1121 TURB  Flame detector, 2nd zone of chamber combustion n°6
0415 28FD-6B MBM12CQ014 1121 TURB  Flame detector, 2nd zone of chamber combustion n°6
Ignition transformer alarm relay
0415 30SG-1 MBM11EH301 1213 TURB
Characteristics : Normal : NO
Air filter inlet curtain low position limit switch
0471 33AG-1A MBL20CG302A A040 FILT Characteristics : Normal : NO
Settings : Flap closed : limit switch activated, contact closed
By-pass flap limit switch
0471 33AG-1B MBL20CG302B A040 FILT Characteristics : Normal : NO
Settings : Flap closed : limit switch activated, contact closed
By-pass flap limit switch
0471 33AG-1C MBL20CG302C A040 FILT Characteristics : Normal : NO
Settings : Flap closed : limit switch activated, contact closed
LO compartment ventilation damper limit switch
0436 33BL-1 SAE41CG301 1634 ENCL-LO Characteristics : Normal : NO
Settings : Damper closed : limit switch activated, contact closed
LO compartment ventilation damper limit switch
0436 33BL-2 SAE42CG301 1634 ENCL-LO Characteristics : Normal : NO
Settings : Damper closed : limit switch activated, contact closed
GT compartment ventilation damper limit switch
0436 33BT-1 SAE27CG301 1605 ENCL-T Characteristics : Normal : NO
Settings : Flap closed : limit switch activated, contact closed
GT compartment ventilation damper limit switch
0436 33BT-2 SAE28CG301 1605 ENCL-T Characteristics : Normal : NO
Settings : Flap closed : limit switch activated, contact closed
Open position bleed valve limit switch
0417 33CB-1A MBH21CG301A 1022 TURB Characteristics : Normal : NO
Settings : Valve open : limit switch activated, contact closed
Closed position bleed valve limit switch
0417 33CB-1B MBH21CG301B 1022 TURB Characteristics : Normal : NO
Settings : Valve closed : limit switch activated, contact closed
Open position bleed valve limit switch
0417 33CB-2A MBH22CG301A 1022 TURB Characteristics : Normal : NO
Settings : Valve open : limit switch activated, contact closed
Open position bleed valve limit switch
0417 33CB-2B MBH22CG301B 1022 TURB Characteristics : Normal : NO
Settings : Valve closed : limit switch activated, contact closed
Open position bleed valve limit switch
0417 33CB-3A MBH23CG301A 1022 TURB Characteristics : Normal : NO
Settings : Valve open : limit switch activated, contact closed
Closed position bleed valve limit switch
0417 33CB-3B MBH23CG301B 1022 TURB Characteristics : Normal : NO
Settings : Valve closed : limit switch activated, contact closed

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 8/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 11 of 69
SIZE DWG NO SH REV
A4 119T3740 9 C TBFT-TMP-FR-GTE-0060 Rev : 001

MLI Wiring
Devices KKS DEVICE MLI Safety Designation
PID Diagram
Open position bleed valve limit switch
0417 33CB-4A MBH24CG301A 1022 TURB Characteristics : Normal : NO
Settings : Valve open : limit switch activated, contact closed
Closed position bleed valve limit switch
0417 33CB-4B MBH24CG301B 1022 TURB Characteristics : Normal : NO
Settings : Valve closed : limit switch activated, contact closed
Load compartment door limit switch
0436 33DT-11 SAE10CG301 1605 ENCL-T Characteristics : Normal : NO
Settings : Door closed : limit switch activated, contact closed
Load compartment door limit switch
0436 33DT-12 SAE10CG302 1605 ENCL-T Characteristics : Normal : NO
Settings : Door closed : limit switch activated, contact closed
GT compartment door limit switch
0436 33DT-21 SAE20CG312 1605 ENCL-T Characteristics : Normal : NO
Settings : Door closed : limit switch activated, contact closed
GT compartment door limit switch
0436 33DT-22 SAE20CG313 1605 ENCL-T Characteristics : Normal : NO
Settings : Door closed : limit switch activated, contact closed
Lube oil compartment door limit switch
0436 33DT-31 SAE40CG301 1634 ENCL-LO Characteristics : Normal : NO
Settings : Door closed : limit switch activated, contact closed
Lube oil compartment door limit switch
0436 33DT-32 SAE40CG302 1634 ENCL-LO Characteristics : Normal : NO
Settings : Door closed : limit switch activated, contact closed
Gas compartment door limit switch
0436 33DT-41 SAE70CG301 1634 ENCL-LO Characteristics : Normal : NO
Settings : Door closed : limit switch activated, contact closed
Gas compartment door limit switch
0436 33DT-42 SAE70CG302 1634 ENCL-LO Characteristics : Normal : NO
Settings : Door closed : limit switch activated, contact closed
Gas compartment door limit switch
0436 33DT-43 SAE70CG303 1634 ENCL-LO Characteristics : Normal : NO
Settings : Door closed : limit switch activated, contact closed
Gas compartment door limit switch
0436 33DT-44 SAE70CG304 1634 ENCL-LO Characteristics : Normal : NO
Settings : Door closed : limit switch activated, contact closed
Gas compartment door limit switch
0436 33DT-45 SAE70CG305 1634 ENCL-LO Characteristics : Normal : NO
Settings : Door closed : limit switch activated, contact closed
GT compartment blow panel limit switch
0436 33DT-71 SAE20CG316 1605 ENCL-T Characteristics : Normal : NO
Settings : Panel closed : limit switch activated, contact closed
GT compartment blow panel limit switch
0436 33DT-72 SAE20CG317 1605 ENCL-T Characteristics : Normal : NO
Settings : Panel closed : limit switch activated, contact closed
Generator compartment ventilation damper limit switch
0436 33GV-1 SAF11CG301 266 ENCL-GEN Characteristics : Normal : NO
Settings : Flap closed : limit switch activated, contact closed
Generator compartment ventilation damper limit switch
0436 33GV-2 SAF12CG301 266 ENCL-GEN Characteristics : Normal : NO
Settings : Flap closed : limit switch activated, contact closed
VM15-1 valve limit switch (valve opened)
0432 33TH-3 MBL70CG301 A037 IBH Characteristics : Normal : NO
Settings : Valve open : limit switch activated, contact closed

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 9/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 12 of 69
SIZE DWG NO SH REV
A4 119T3740 10 C TBFT-TMP-FR-GTE-0060 Rev : 001

MLI Wiring
Devices KKS DEVICE MLI Safety Designation
PID Diagram
Load compartment ventilation damper limit switch
0436 33VG-1 SAE11CG301 1605 ENCL-T Characteristics : Normal : NO
Settings : Flap closed : limit switch activated, contact closed
Gas system vent valve limit switch
0422 33VG-11 MBP70CG301 A160 LO FG Characteristics : Normal : NO
Settings : | Contact closed | Valve closed | Limit switch activated
Load compartment ventilation damper limit switch
0436 33VG-2 SAE12CG301 1605 ENCL-T Characteristics : Normal : NO
Settings : Flap closed : limit switch activated, contact closed
Gas fuel vent valve VA13-18 limit switch
0422 33VG-8 MBP68CG321 G064 FG-SSOV Characteristics : Normal : NO
Settings : | Contact closed | Valve closed | Limit switch activated
Gas fuel vent valve VA13-18 limit switch
0422 33VG-9 MBP68CG322 G064 FG-SSOV Characteristics : Normal : NO
Settings : | Contact closed | Valve open | Limit switch activated
Start up gas heat vent valve (VGV-10) limit switch
0422 33VGV-10H MBP70CG391 A160 LO FG Characteristics : Normal : NO
Settings : | Contact closed | Valve open | Limit switch activated
Start up gas heat vent valve (VGV-10) limit switch
0422 33VGV-10L MBP70CG390 A160 LO FG Characteristics : Normal : NO
Settings : | Contact closed | Valve closed | Limit switch activated
Gas compartment ventilation damper limit switch
0436 33VL-1 SAE71CG301 1634 ENCL-LO Characteristics : Normal : NO
Settings : Flap closed : limit switch activated, contact closed
Gas compartment ventilation damper limit switch
0436 33VL-2 SAE72CG301 1634 ENCL-LO Characteristics : Normal : NO
Settings : Flap closed : limit switch activated, contact closed
Fuel gas stop valve (VS4-4) limit switch
0422 33VS4-4 MBP68CG311 G064 FG-SSOV Characteristics : Normal : NO
Settings : | Contact closed | Valve closed | Limit switch activated
Fuel gas stop valve (VS4-4) limit switch
0422 33VS4-5 MBP68CG312 G064 FG-SSOV Characteristics : Normal : NO
Settings : | Contact closed | Valve open | Limit switch activated


Vibration sensor
0415 39V-1A MBD10CS001A 218A TURB
Characteristics : For 25.4 mm/s (1 in/s), 150 ± 4.5 mV peak


Vibration sensor
0415 39V-1B MBD10CS001B 218A TURB
Characteristics : For 25.4 mm/s (1 in/s), 150 ± 4.5 mV peak


Vibration sensor
0415 39V-2A MBD20CS001A 218B TURB
Characteristics : For 25.4 mm/s (1 in/s), 150 ± 4.5 mV peak


Vibration sensor
0415 39V-2B MBD20CS001B 218B TURB
Characteristics : For 25.4 mm/s (1 in/s), 150 ± 4.5 mV peak
LoadGear casing seismic sensor,Hspeed shaft GT side
0495 39V-4D MBJ20CY001A A012 LOAD
Characteristics : For 25.4 mm/s (1 in/s), 145 ± 4.5 mV peak
LoadGear casing seismic sensor,Hspeed shaft GT side
0495 39V-4E MBJ20CY001B A012 LOAD
Characteristics : For 25.4 mm/s (1 in/s), 145 ± 4.5 mV peak
LoadGear casing seismic sensor,lspeed shaft GENside
0495 39V-4F MBJ20CY001C A012 LOAD
Characteristics : For 25.4 mm/s (1 in/s), 145 ± 4.5 mV peak
Vibration sensor bearing #1
0415 39VS-11 MBD10CY001A 235A TURB Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil)
Settings : Gap : -10.5 ± 0.5 VDC
Vibration sensor bearing #1
0415 39VS-12 MBD10CY001B 235A TURB Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil)
Settings : Gap : -10.5 ± 0.5 VDC

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 10/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 13 of 69
SIZE DWG NO SH REV
A4 119T3740 11 C TBFT-TMP-FR-GTE-0060 Rev : 001

MLI Wiring
Devices KKS DEVICE MLI Safety Designation
PID Diagram
Vibration sensor bearing #2
0415 39VS-21 MBD20CY002A 235B TURB Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil)
Settings : Gap : -10.5 ± 0.5 VDC
Vibration sensor bearing #2
0415 39VS-22 MBD20CY002B 235B TURB Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil)
Settings : Gap : -10.5 ± 0.5 VDC
Vibration sensor
0495 39VS-51 MBJ20CY002 A012 LOAD Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil)
Settings : Gap : 1.4 ± 0.05 mm (0.055 ± 0.002 in)
Vibration sensor
0495 39VS-52 MBJ20CY003 A012 LOAD Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil)
Settings : Gap : 1.4 ± 0.05 mm (0.055 ± 0.002 in)
Vibration sensor
0495 39VS-61 MBJ20CY004 A012 LOAD Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil)
Settings : Gap : 1.4 ± 0.05 mm (0.055 ± 0.002 in)
Vibration sensor
0495 39VS-62 MBJ20CY005 A012 LOAD Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil)
Settings : Gap : 1.4 ± 0.05 mm (0.055 ± 0.002 in)
Vibration sensor
0495 39VS-71 MBJ20CY006 A012 LOAD Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil)
Settings : Gap : 1.4 ± 0.05 mm (0.055 ± 0.002 in)
Vibration sensor
0495 39VS-72 MBJ20CY007 A012 LOAD Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil)
Settings : Gap : 1.4 ± 0.05 mm (0.055 ± 0.002 in)
Vibration sensor
0495 39VS-81 MBJ20CY008 A012 LOAD Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil)
Settings : Gap : 1.4 ± 0.05 mm (0.055 ± 0.002 in)
Vibration sensor
0495 39VS-82 MBJ20CY009 A012 LOAD Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil)
Settings : Gap : 1.4 ± 0.05 mm (0.055 ± 0.002 in)
Break glass unit
0426 43CP-1 SGJ70CH001 1113 ENCL-T
Characteristics : Normal : NO
Break glass unit
0426 43CP-12 SGJ50CH015 1137 ENCL-LO
Characteristics : Normal : NO
Break glass unit gas compartment
0426 43CP-13 SGJ50CH002 1137 ENCL-LO
Characteristics : Normal : NO
Break glass unit gas compartment
0426 43CP-14 SGJ50CH003 1137 ENCL-LO
Characteristics : Normal : NO
Break glass unit gas compartment
0426 43CP-15 SGJ50CH004 1137 ENCL-LO
Characteristics : Normal : NO
Break glass unit
0426 43CP-2 SGJ10CH001 1113 ENCL-T
Characteristics : Normal : NO
Break glass unit
0426 43CP-3 SGJ70CH002 1113 ENCL-T
Characteristics : Normal : NO
Break glass unit
0426 43CP-4 SGJ10CH002 1113 ENCL-T
Characteristics : Normal : NO
Thermostatic fire detector
0426 45FA-1A SGJ30CT301A 1137 ENCL-LO Characteristics : Normal : NO
Settings : Closed : 163 ± 14°C (325 ± 25°F)
Thermostatic fire detector
0426 45FA-1B SGJ30CT301B 1137 ENCL-LO Characteristics : Normal : NO
Settings : Closed : 163 ± 14°C (325 ± 25°F)

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 11/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 14 of 69
SIZE DWG NO SH REV
A4 119T3740 12 C TBFT-TMP-FR-GTE-0060 Rev : 001

MLI Wiring
Devices KKS DEVICE MLI Safety Designation
PID Diagram
Thermostatic fire detector
0426 45FA-2A SGJ30CT302A 1137 ENCL-LO Characteristics : Normal : NO
Settings : Closed : 163 ± 14°C (325 ± 25°F)
Thermostatic fire detector
0426 45FA-2B SGJ30CT302B 1137 ENCL-LO Characteristics : Normal : NO
Settings : Closed : 163 ± 14°C (325 ± 25°F)
Thermostatic fire detector
0426 45FA-6A SGJ50CT306A 1137 ENCL-LO Characteristics : Normal : NO
Settings : Closed : 163 ± 14°C (325 ± 25°F)
Thermostatic fire detector
0426 45FA-6B SGJ50CT306B 1137 ENCL-LO Characteristics : Normal : NO
Settings : Closed : 163 ± 14°C (325 ± 25°F)
Thermostatic fire detector
0426 45FA-7A SGJ50CT307A 1137 ENCL-LO Characteristics : Normal : NO
Settings : Closed : 163 ± 14°C (325 ± 25°F)
Thermostatic fire detector
0426 45FA-7B SGJ50CT307B 1137 ENCL-LO Characteristics : Normal : NO
Settings : Closed : 316 ± 14°C (600 ± 25°F)
Thermostatic fire detector
0426 45FT-10A SGJ70CT301A 1113 ENCL-T  Characteristics : Normal : NO
Settings : Closed : 163 ± 14°C (325 ± 25°F)
Thermostatic fire detector
0426 45FT-10B SGJ70CT301B 1113 ENCL-T  Characteristics : Normal : NO
Settings : Closed : 163 ± 14°C (325 ± 25°F)
Thermostatic fire detector
0426 45FT-11A SGJ70CT302A 1113 ENCL-T  Characteristics : Normal : NO
Settings : Closed : 163 ± 14°C (325 ± 25°F)
Thermostatic fire detector
0426 45FT-11B SGJ70CT302B 1113 ENCL-T  Characteristics : Normal : NO
Settings : Closed : 163 ± 14°C (325 ± 25°F)
Thermostatic fire detector
0426 45FT-1A SGJ10CT301A 1103 TURB  Characteristics : Normal : NO
Settings : Closed : 316 ± 14°C (600 ± 25°F)
Thermostatic fire detector
0426 45FT-1B SGJ10CT301B 1103 TURB  Characteristics : Normal : NO
Settings : Closed : 316 ± 14°C (600 ± 25°F)
Thermostatic fire detector
0426 45FT-2A SGJ10CT302A 1154 TURB  Characteristics : Normal : NO
Settings : Closed : 316 ± 14°C (600 ± 25°F)
Thermostatic fire detector
0426 45FT-2B SGJ10CT302B 1154 TURB  Characteristics : Normal : NO
Settings : Closed : 316 ± 14°C (600 ± 25°F)
Thermostatic fire detector
0426 45FT-3A SGJ10CT303A 1154 TURB  Characteristics : Normal : NO
Settings : Closed : 316 ± 14°C (600 ± 25°F)
Thermostatic fire detector
0426 45FT-3B SGJ10CT303B 1154 TURB  Characteristics : Normal : NO
Settings : Closed : 316 ± 14°C (600 ± 25°F)
Thermostatic fire detector turbine compartment
0426 45FT-4A SGJ10CT304A 1113 ENCL-T  Characteristics : Normal : NO
Settings : Closed : 316 ± 14°C (600 ± 25°F)
Thermostatic fire detector turbine compartment
0426 45FT-4B SGJ10CT304B 1113 ENCL-T  Characteristics : Normal : NO
Settings : Closed : 316 ± 14°C (600 ± 25°F)

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 12/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 15 of 69
SIZE DWG NO SH REV
A4 119T3740 13 C TBFT-TMP-FR-GTE-0060 Rev : 001

MLI Wiring
Devices KKS DEVICE MLI Safety Designation
PID Diagram
Thermostatic fire detector turbine compartment
0426 45FT-5A SGJ10CT305A 1113 ENCL-T  Characteristics : Normal : NO
Settings : Closed : 316 ± 14°C (600 ± 25°F)
Thermostatic fire detector turbine compartment
0426 45FT-5B SGJ10CT305B 1113 ENCL-T  Characteristics : Normal : NO
Settings : Closed : 316 ± 14°C (600 ± 25°F)
Thermostatic fire detector
0426 45FT-8A SGJ20CT301A 1160 TURB Characteristics : Normal : NO
Settings : Closed : 316 ± 14°C (600 ± 25°F)
Thermostatic fire detector
0426 45FT-8B SGJ20CT301B 1160 TURB Characteristics : Normal : NO
Settings : Closed : 316 ± 14°C (600 ± 25°F)
Thermostatic fire detector
0426 45FT-9A SGJ20CT302A 1160 TURB Characteristics : Normal : NO
Settings : Closed : 316 ± 14°C (600 ± 25°F)
Thermostatic fire detector
0426 45FT-9B SGJ20CT302B 1160 TURB Characteristics : Normal : NO
Settings : Closed : 316 ± 14°C (600 ± 25°F)


Gas detector gas compartment ventilation duct
0474 45HA-4 CYQ11CU004 1634 ENCL-LO
Characteristics : Range : 0 - 20% LEL


Gas detector gas compartment ventilation duct
0474 45HA-5 CYQ11CU005 1634 ENCL-LO
Characteristics : Range : 0 - 20% LEL


Gas detector turbine compartment
0474 45HT-1 CYQ10CU001 1154 TURB
Characteristics : Range : 0 - 100%±2% LEL


Gas detector turbine compartment
0474 45HT-2 CYQ10CU002 1154 TURB
Characteristics : Range : 0 - 100%±2% LEL


Gas detector turbine compartment
0474 45HT-4 CYQ10CU004 1605 ENCL-T
Characteristics : Range : 0 - 20% LEL


Gas detector turbine compartment ventilation duct
0474 45HT-5 CYQ10CU005 1605 ENCL-T
Characteristics : Range : 0 - 20% LEL
Security thermostat lube oil compartment heater
0436 49BL-1 SAE40CT302 1634 ENCL-LO Characteristics : Normal : NC
Settings : Opened at 98°C +0/-16°C (208,4°F +0/-61°F)
Security thermostat gas compartment heater
0436 49VL-2 SAE70CT007 1634 ENCL-LO Characteristics : Normal : NC
Settings : Opened at 98°C +0/-16°C (208,4°F +0/-61°F)
Electro-pneumatic transducer
Settings :
0432 65EP-3 MBL70CG002 A037 IBH
04 ± 0.01 mA for VA20-1 fully opened
20 ± 0.01 mA for VA20-1 fully closed
0422 65GC-1 MBP71AA210B 0509 LO FG Gas control valve servo valve (VGC-1)
0422 65GC-2 MBP72AA210B 0509 LO FG Gas control valve servo valve (VGC-2)
0422 65GC-3 MBP73AA210B 0509 LO FG Gas control valve servo valve (VGC-3)
0422 65GC-4 MBP74AA210B 0509 LO FG Gas control valve servo valve (VGC-4)
Very low level lube oil tank detector
Characteristics : Normal : NO
0416 71QT-1 MBV10CL304 A160 LO FG
Settings : Decrease open on low level at 750 ± 5 mm of floating
device stroke


Speed sensor
0415 77HT-1 MBY10CS001 0546 TURB
Settings : Gap : 1.27 ± 0.127 mm (0.05 ± 0.005 in)


Speed sensor
0415 77HT-2 MBY10CS002 0546 TURB
Settings : Gap : 1.27 ± 0.127 mm (0.05 ± 0.005 in)

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 13/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 16 of 69
SIZE DWG NO SH REV
A4 119T3740 14 C TBFT-TMP-FR-GTE-0060 Rev : 001

MLI Wiring
Devices KKS DEVICE MLI Safety Designation
PID Diagram


Speed sensor
0415 77HT-3 MBY10CS003 0546 TURB
Settings : Gap : 1.27 ± 0.127 mm (0.05 ± 0.005 in)
Speed sensor
0415 77NH-1 MBY10CS011 0546 TURB
Settings : Gap : 1.27 ± 0.127 mm (0.05 ± 0.005 in)
Speed sensor
0415 77NH-2 MBY10CS012 0546 TURB
Settings : Gap : 1.27 ± 0.127 mm (0.05 ± 0.005 in)
Speed sensor
0415 77NH-3 MBY10CS013 0546 TURB
Settings : Gap : 1.27 ± 0.127 mm (0.05 ± 0.005 in)
Keyphasor, low speed shaft end drive generator side
0495 77RP-101 MBJ20CY010 A012 LOAD Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil)
Settings : Gap : -10.5 ± 0.5 VDC
Keyphasor
0415 77RP-11 MBD10CY003 235A TURB Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil)
Settings : Gap : -10.5 ± 0.5 VDC
Cooling air fan motor oil compartment
0436 88BL-1 SAE41AN001-M01 1634 ENCL-LO
Characteristics : 1.8 kW | NC | 50 Hz | 380 VAC
Cooling air fan motor oil compartment
0436 88BL-2 SAE42AN001-M01 1634 ENCL-LO
Characteristics : 1.8 kW | NC | 50 Hz | 380 VAC
2nd bearing cooling fan vent motor
0417 88BN-1 MBH15AN001-M01 A132 AIR
Characteristics : 15 kW | 3000 rpm | 27A | 50 Hz | 380 VAC
2nd bearing cooling fan vent motor
0417 88BN-2 MBH15AN002-M01 A132 AIR
Characteristics : 15 kW | 3000 rpm | 27A | 50 Hz | 380 VAC
Cooling air fan motor - acoustical enclosure GT compartment
0436 88BT-1 SAE27AN001-M01 1605 ENCL-T
Characteristics : 55 kW | NC | 96A | 50 Hz | 380 VAC
Cooling air fan motor - acoustic enclosure GT compartment
0436 88BT-2 SAE28AN001-M01 1605 ENCL-T
Characteristics : 55 kW | NC | 96A | 50 Hz | 380 VAC
Cooling air fan motor generator compartment
0436 88GV-1 SAF11AN001-M01 266 ENCL-GEN
Characteristics : 4 kW | 3000rpm | 50 Hz | 380 VAC
Cooling air fan motor generator compartment
0436 88GV-2 SAF12AN001-M01 266 ENCL-GEN
Characteristics : 4 kW | 3000rpm | 50 Hz | 380 VAC
Auxiliary hydraulic supply pump motor
0434 88HQ-1 MBX11AP001-M01 0627 LO FG
Characteristics : 15 kW | 1500 rpm | 29.5A | 50 Hz | 380 VAC
Pump motor - hydraulic supply n°2
0434 88HQ-2 MBX12AP001-M01 0627 LO FG
Characteristics : 15 kW | 1500 rpm | 29.5A | 50 Hz | 380 VAC
Auxiliary lube oil pump motor
0416 88QA-1 MBV20AP001-M01 1005 LO FG
Characteristics : 75 kW | 3000 rpm | 133A | 50 Hz | 380 VAC
PQ1-2 oil pump motor
0416 88QA-2 MBV20AP002-M01 1006 LO FG
Characteristics : 75 kW | 3000 rpm | 133A | 50 Hz | 380 VAC
Emergency lube oil pump motor
0416 88QE-1 MBV30AP001-M01 1007 LO FG
Characteristics : 30 kW | 3000 rpm | 290A | 125 VDC
Lube oil mist eliminator motor
0416 88QV-1A MBV11AN001-M01 A160 LO FG
Characteristics : 5.5 kW | 3000 rpm | 10.9A | 50 Hz | 380 VAC
Lube oil mist eliminator motor
0416 88QV-1B MBV11AN002-M01 A160 LO FG
Characteristics : 5.5 kW | 3000 rpm | 10.9A | 50 Hz | 380 VAC
Turning gear induction motor
0495 88TG-1 MBJ20AE001-M01 A012 LOAD
Characteristics : 18.5 kW | 1000 rpm | 38A | 50 Hz | 380 VAC
Turbine exhaust frame cooling blower & motor
0417 88TK-1 MBH10AN001-M01 A132 AIR
Characteristics : 30 kW | 3000 rpm | 52A | 50 Hz | 380 VAC
Turbine exhaust frame cooling blower & motor
0417 88TK-2 MBH10AN002-M01 A132 AIR
Characteristics : 30 kW | 3000 rpm | 52A | 50 Hz | 380 VAC

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 14/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 17 of 69
SIZE DWG NO SH REV
A4 119T3740 15 C TBFT-TMP-FR-GTE-0060 Rev : 001

MLI Wiring
Devices KKS DEVICE MLI Safety Designation
PID Diagram
Cooling air fan motor acoustic enclosure load compartment
0436 88VG-1 SAE11AN001-M01 1605 ENCL-T
Characteristics : 4 kW | 3000 rpm | 50 Hz | 380 VAC
Cooling air fan motor acoustic enclosure load compartment
0436 88VG-2 SAE12AN001-M01 1605 ENCL-T
Characteristics : 4 kW | 3000 rpm | 50 Hz | 380 VAC
Cooling air fan motor gas module acoustic enclosure
0436 88VL-1 SAE71AN001-M01 1634 ENCL-LO
Characteristics : 5.5 kW | 1500 rpm | 50 Hz | 380 VAC
Cooling air fan motor gas module acoustic enclosure
0436 88VL-2 SAE72AN001-M01 1634 ENCL-LO
Characteristics : 5,5 kW | 1500 rpm | 50 Hz | 380 VAC
CW control valve positioner - LO temperature
Settings :
0420 90LT-1 MBE32AA211A 1035 LO FG 04 mA : 0 +0.1/-0 mm stroke (0 +0.039/-0 in)(100% of cooler flow)
20 mA : 40 +0/-0.2 mm stroke (1.57 +0.0/-0.008 in) (0% of cooler
flow)
0422 90SR-1 MBP70AA220B 0507 LO FG Gas speed ratio/stop valve servo valve
0469 90TV-1 MBC20AA201E 0548 TURB Servovalve, compressor IGV actuator
Air flow ventilation control for GT enclosure
Characteristics : 125 VDC | 04 - 20 mA for 0.5 - 30 m/s

Settings : fan not running, 0% air flow : 4 -0/+1 mA
0436 95BT-1 SAE20CF001 1113 ENCL-T
fan running and doors closed : x1 mA, adjust the speedtronic
constant software at a value equivalent to { [60% * (x1 -
4) ] + 4 mA }
Air flow ventilation control for GT enclosure
Characteristics : 125 VDC | 04 - 20 mA for 0.5 - 30 m/s

Settings : fan not running, 0% air flow : 4 -0/+1 mA
0436 95BT-2 SAE20CF002 1113 ENCL-T
fan running and doors closed : x1 mA, adjust the speedtronic
constant software at a value equivalent to { [60% * (x1 -
4) ] + 4 mA }
Air flow ventilation control for GT enclosure
Characteristics : 125 VDC | 04 - 20 mA for 0.5 - 30 m/s

Settings : fan not running, 0% air flow : 4 -0/+1 mA
0436 95BT-3 SAE20CF003 1113 ENCL-T
fan running and doors closed : x1 mA, adjust the speedtronic
constant software at a value equivalent to { [60% * (x1 -
4) ] + 4 mA }
Air flow ventilation control for GT enclosure
Characteristics : 125 VDC | 04 - 20 mA for 0.5 - 30 m/s

Settings : fan not running, 0% air flow : 4 -0/+1 mA
0436 95BT-4 SAE20CF004 1113 ENCL-T
fan running and doors closed : x1 mA, adjust the speedtronic
constant software at a value equivalent to { [60% * (x1 -
4) ] + 4 mA }
Air flow ventilation control for GT enclosure
Characteristics : 125 VDC | 04 - 20 mA for 0.5 - 30 m/s

Settings : fan not running, 0% air flow : 4 -0/+1 mA
0436 95BT-5 SAE20CF005 1113 ENCL-T
fan running and doors closed : x1 mA, adjust the speedtronic
constant software at a value equivalent to { [60% * (x1 -
4) ] + 4 mA }
Air flow ventilation control for GT enclosure
Characteristics : 125 VDC | 04 - 20 mA for 0.5 - 30 m/s

Settings : fan not running, 0% air flow : 4 -0/+1 mA
0436 95BT-6 SAE20CF006 1113 ENCL-T
fan running and doors closed : x1 mA, adjust the speedtronic
constant software at a value equivalent to { [60% * (x1 -
4) ] + 4 mA }
Anti-icing exchanger inlet temperature transmitter
Settings :
0471 96HW-1 MBL20CT011 A040 FILT
04 ± 0.05 mA for -40°C (-40°F)
20 ± 0.1 mA for 150°C (302°F)

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 15/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 18 of 69
SIZE DWG NO SH REV
A4 119T3740 16 C TBFT-TMP-FR-GTE-0060 Rev : 001

MLI Wiring
Devices KKS DEVICE MLI Safety Designation
PID Diagram
Dew point and temperature transmitter
Settings :
Output 1 :
04 ± 0.05 mA for -50°C (-58 °F)
0471 96RH-1 MBL40CM001 A040 FILT
20 ± 0.05 mA for +50°C (122 °F)
Output 2 :
04 ± 0.05 mA for 0% RH
20 ± 0.05 mA for 100 % RH
Ignition transformer for spark plug
0415 95SG-4 MBM11GT004 1213 TURB
Characteristics : 0.15 kVA | 50 Hz | 230 VAC
Ignition transformer for spark plug
0415 95SG-5 MBM11GT005 1213 TURB
Characteristics : 0.15 kVA | 50 Hz | 230 VAC
0415 95SP-4 MBM11AV004 1214 TURB Spark plug for combustion chamber n°4
0415 95SP-5 MBM11AV005 1214 TURB Spark plug for combustion chamber n°5
Air flow control (anemometer) for gas enclosure
Characteristics : 125 VDC | 04 - 20 mA for 0.5 - 30 m/s
Settings : fan not running, 0% air flow : 4 -0/+1 mA
0436 95VL-1 SAE70CF001 1137 ENCL-LO
fan running and doors closed : x1 mA, adjust the speedtronic
constant software at a value equivalent to { [60% * (x1 -
4) ] + 4 mA }
Air flow control (anemometer) for gas enclosure
Characteristics : 125 VDC | 04 - 20 mA for 0.5 - 30 m/s
Settings : fan not running, 0% air flow : 4 -0/+1 mA
0436 95VL-2 SAE70CF002 1137 ENCL-LO
fan running and doors closed : x1 mA, adjust the speedtronic
constant software at a value equivalent to { [60% * (x1 -
4) ] + 4 mA }
Air flow control (anemometer) for gas enclosure
Characteristics : 125 VDC | 04 - 20 mA for 0.5 - 30 m/s
Settings : fan not running, 0% air flow : 4 -0/+1 mA
0436 95VL-3 SAE70CF003 1137 ENCL-LO
fan running and doors closed : x1 mA, adjust the speedtronic
constant software at a value equivalent to { [60% * (x1 -
4) ] + 4 mA }
Pressure transmitter
Settings :
0492 96AP-1A MBL90CP030A 0559 TURB
04 ± 0.02 mA for 0.745 bar abs (22 in of Hg)
20 ± 0.10 mA for 1.250 bar abs (37 in of Hg)
Pressure transmitter
Settings :
0492 96AP-1B MBL90CP030B 0559 TURB
04 ± 0.02 mA for 0.745 bar abs (22 in of Hg)
20 ± 0.10 mA for 1.250 bar abs (37 in of Hg)
Pressure transmitter
Settings :
0492 96AP-1C MBL90CP030C 0559 TURB
04 ± 0.02 mA for 0.745 bar abs (22 in of Hg)
20 ± 0.10 mA for 1.250 bar abs (37 in of Hg)
DiffPress transmitter between air inlet&intake bell
Settings :
0492 96BD-1 MBL90CP002 0559 TURB
04 ± 0.02 mA for 0.000 bar (0.000 in of H2O)
20 ± 0.10 mA for 0.345 bar (138.5 in of H2O)
Inlet HTG CV upstream pressure transmitter
Characteristics : 10.5 to 36 VCC
0432 96BH-1 MBL70CP001 A037 IBH Settings :
04 ± 0.05 mA for 0 bar (0 psi)
20 ± 0.1 mA for 20,7 bar (300 psi)

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 16/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 19 of 69
SIZE DWG NO SH REV
A4 119T3740 17 C TBFT-TMP-FR-GTE-0060 Rev : 001

MLI Wiring
Devices KKS DEVICE MLI Safety Designation
PID Diagram
Inlet HTG CV downstream pressure transmitter
Characteristics : 10.5 to 36 VCC
0432 96BH-2 MBL70CP002 A037 IBH Settings :
04 ± 0.05 mA for 0 bar (0 psi)
20 ± 0.1 mA for 10 bar (145 psi)
2ndbearing cooling blower discharge pressure transmitter
Characteristics : Normal : NO
0417 96BN-1 MBH15CP001 A132 AIR Settings :
04 ± 0.05 mA for 0 Pa (0 psi)
20 ± 0.05 mA for 8272 Pa (1.2 psi)
2ndbearing cooling blower discharge pressure transmitter
Characteristics : Normal : NO
0417 96BN-2 MBH15CP002 A132 AIR Settings :
04 ± 0.05 mA for 0 Pa (0 psi)
20 ± 0.05 mA for 8272 Pa (1.2 psi)


Pressure transmitter, air inlet 88BN compartment detecting the
0436 96BN-90 SAE10CP005 1605 ENCL-T
clogging of the compartment air inlet filters
Compressor discharge pressure transmitter
Characteristics : 0 to 5 ± 0,05 VDC
0417 96CD-1A MBH90CP001A 557T TURB Settings :
04 ± 0.05 mA for 0 bar (0 psi)
20 ± 0.05 mA for 20.7 bar (300 psi)
Compressor discharge pressure transmitter
Characteristics : 0 to 5 ± 0,05 VDC
0417 96CD-1B MBH90CP001B 557T TURB Settings :
04 ± 0.05 mA for 0 bar (0 psi)
20 ± 0.05 mA for 20.7 bar (300 psi)
Compressor discharge pressure transmitter
Characteristics : 0 to 5 ± 0,05 VDC
0417 96CD-1C MBH90CP001C 557T TURB Settings :
04 ± 0.05 mA for 0 bar (0 psi)
20 ± 0.05 mA for 20.7 bar (300 psi)
DiffPress transmitter between air inlet&intake bell
Settings :
0492 96CS-1 MBL90CP001 0559 TURB
04 ± 0.02 mA for 0 mbar
20 ± 0.10 mA for 27.4 mbar (11 in of H2O)
Pressure transmitter

Settings :
0492 96EP-1A MBR10CP001A 0559 TURB
04 ± 0,02 mA for 0,0000 bar (00 in of H2O)
20 ± 0,10 mA for 74.7 mbar (30 in of H2O)
Pressure transmitter
Settings :
0492 96EP-1B MBR10CP001B 0559 TURB
04 ± 0,02 mA for 0,0000 bar (00 in of H2O)
20 ± 0,10 mA for 74.7 mbar (30 in of H2O)
Pressure transmitter measuring gas exhaust pressure
Settings :
0492 96EP-1C MBR10CP001C 0559 TURB
04 ± 0,02 mA for 0,0000 bar (00 in of H2O)
20 ± 0,10 mA for 74.7 mbar (30 in of H2O)
Inlet gas fuel module pressure transmitter
Characteristics : 9 to 30 VDC
0422 96FG-1A MBP70CP001A A160 LO FG Settings :
04 ± 0.05 mA for 0 bar (0 psi)
20 ± 0.1 mA for 34.5 bar (500 psi)
Inlet gas fuel module pressure transmitter
Characteristics : 9 to 30 VDC
0422 96FG-1B MBP70CP001B A160 LO FG Settings :
04 ± 0.05 mA for 0 bar (0 psi)
20 ± 0.1 mA for 34.5 bar (500 psi)

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 17/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 20 of 69
SIZE DWG NO SH REV
A4 119T3740 18 C TBFT-TMP-FR-GTE-0060 Rev : 001

MLI Wiring
Devices KKS DEVICE MLI Safety Designation
PID Diagram
Inlet gas fuel module pressure transmitter
Characteristics : 9 to 30 VDC
0422 96FG-1C MBP70CP001C A160 LO FG Settings :
04 ± 0.05 mA for 0 bar (0 psi)
20 ± 0.1 mA for 34.5 bar (500 psi)
Fuel gas inter-valve pressure transmitter
Characteristics : 9 to 30 VDC
0422 96FG-2A MBP70CP003A A160 LO FG  Settings :
04 ± 0.1 mA for 0 bar (0 psi)
20 ± 0.1 mA for 34.5 bar (500 psi)
Fuel gas inter-valve pressure transmitter
Characteristics : 9 to 30 VDC
0422 96FG-2B MBP70CP003B A160 LO FG  Settings :
04 ± 0.1 mA for 0 bar (0 psi)
20 ± 0.1 mA for 34.5 bar (500 psi)
Fuel gas inter-valve pressure transmitter
Characteristics : 9 to 30 VDC
0422 96FG-2C MBP70CP003C A160 LO FG  Settings :
04 ± 0.1 mA for 0 bar (0 psi)
20 ± 0.1 mA for 34.5 bar (500 psi)


Linear Variable Diff Transformer of VGC-1
0422 96GC-1A MBP71CG011A 0509 LO FG
Settings : 0.7 ± 0.1 V = 0% open | 3.5 ± 0.5 V = 100% open


Linear Variable Diff Transformer of VGC-1
0422 96GC-1B MBP71CG011B 0509 LO FG
Settings : 0.7 ± 0.1 V = 0% open | 3.5 ± 0.5 V = 100% open


Linear Variable Diff Transformer of VGC-2
0422 96GC-2A MBP72CG011A 0509 LO FG
Settings : 0.7 ± 0.1 V = 0% open | 3.5 ± 0.5 V = 100% open


Linear Variable Diff Transformer of VGC-2
0422 96GC-2B MBP72CG011B 0509 LO FG
Settings : 0.7 ± 0.1 V = 0% open | 3.5 ± 0.5 V = 100% open


Linear Variable Diff Transformer of VGC-3
0422 96GC-3A MBP73CG011A 0509 LO FG
Settings : 0.7 ± 0.1 V = 0% open | 3.5 ± 0.5 V = 100% open


Linear Variable Diff Transformer of VGC-3
0422 96GC-3B MBP73CG011B 0509 LO FG
Settings : 0.7 ± 0.1 V = 0% open | 3.5 ± 0.5 V = 100% open


Linear Variable Diff Transformer of VGC-4
0422 96GC-4A MBP74CG011A 0509 LO FG
Settings : 0.7 ± 0.1 V = 0% open | 3.5 ± 0.5 V = 100% open


Linear Variable Diff Transformer of VGC-4
0422 96GC-4B MBP74CG011B 0509 LO FG
Settings : 0.7 ± 0.1 V = 0% open | 3.5 ± 0.5 V = 100% open
Sampling flow analog transmitter

Settings :
0474 96GDHA-4 CYQ11CF014 0585 ENCL-LO
04 ± 0.04 mA for 0 l/h (0 GPH)
20 ± 0.2 mA for 200 l/h (52.8 GPH))
Sampling flow analog transmitter

Settings :
0474 96GDHA-5 CYQ11CF015 0585 ENCL-LO
04 ± 0.04 mA for 0 l/h (0 GPH)
20 ± 0.2 mA for 200 l/h (52.8 GPH)
Sampling flow analog transmitter

Settings :
0474 96GDHT-1 CYQ10CF011 0585 ENCL-T
04 ± 0.04 mA for 0 l/h (0 GPH)
20 ± 0.2 mA for 200 l/h (52.8 GPH)
Sampling flow analog transmitter

Settings :
0474 96GDHT-2 CYQ10CF012 0585 ENCL-T
04 ± 0.04 mA for 0 l/h (0 GPH)
20 ± 0.2 mA for 200 l/h (52.8 GPH)

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 18/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 21 of 69
SIZE DWG NO SH REV
A4 119T3740 19 C TBFT-TMP-FR-GTE-0060 Rev : 001

MLI Wiring
Devices KKS DEVICE MLI Safety Designation
PID Diagram
Sampling flow analog transmitter

Settings :
0474 96GDHT-4 CYQ10CF014 0585 ENCL-T
04 ± 0.04 mA for 0 l/h (0 GPH)
20 ± 0.2 mA for 200 l/h (52.8 GPH)
Sampling flow analog transmitter

Settings :
0474 96GDHT-5 CYQ10CF015 0585 ENCL-T
04 ± 0.04 mA for 0 l/h (0 GPH)
20 ± 0.2 mA for 200 l/h (52.8 GPH)
Fuel gas filter differential pressure transmitter
Settings :
0422 96GQ-1 MBP70CP025 A160 LO FG
04 ± 0.1 mA for 0 bar
20 ± 0.1 mA for 1.5 bar (22 psi)
Gas detector transmitter

Settings :
0474 96HA-4 CYQ11CU014 1137 ENCL-LO
04 ± 0.04 mA for 0% of the LEL
20 ± 0.2 mA for 100% of the LEL
Gas detector transmitter

Settings :
0474 96HA-5 CYQ11CU015 1137 ENCL-LO
04 ± 0.04 mA for 0% of the LEL
20 ± 0.2 mA for 100% of the LEL
Hydraulic oil filter diff press transmitter
Settings :
0434 96HF-1 MBX11CP010 A160 LO FG
04 ± 0.05 mA for 0 bar (0 psi)
20 ± 0.1 mA for 7 bar (101.5 psi)
Hydraulic oil supply pressure transmitter
Characteristics : 12 to 45 VDC
0434 96HQ-1 MBX20CP010 A160 LO FG Settings :
04 ± 0.1 mA for 0 bar (0 psi)
20 ± 0.1 mA for 100 bar (1450 psi)
Gas detector transmitter

Settings :
0474 96HT-1 CYQ10CU011 1113 ENCL-T
04 ± 0.04 mA for 0% of the LEL
20 ± 0.2 mA for 100% of the LEL
Gas detector transmitter

Settings :
0474 96HT-2 CYQ10CU012 1113 ENCL-T
04 ± 0.04 mA for 0% of the LEL
20 ± 0.2 mA for 100% of the LEL
Gas detector transmitter

Settings :
0474 96HT-4 CYQ10CU014 1113 ENCL-T
04 ± 0.04 mA for 0% of the LEL
20 ± 0.2 mA for 100% of the LEL
Gas detector transmitter

Settings :
0474 96HT-5 CYQ10CU015 1113 ENCL-T
04 ± 0.04 mA for 0% of the LEL
20 ± 0.2 mA for 100% of the LEL
Auxiliary LO pump discharge pressure transmitter
0416 96QA-11 MBV20CP004 A160 ACCY Settings : 04 ± 0.05 mA for 0 bar (0 psi)
20 ± 0.05 mA for 5 bar (72.5 psi)
Main lube oil pump discharge pressure transmitter
0416 96QA-12 MBV20CP005 A160 ACCY Settings : 04 ± 0.05 mA for 0 bar (0 psi)
20 ± 0.05 mA for 5 bar (72.5 psi)
Emergency pump discharge pressure transmitter
Settings :
0416 96QE-1 MBV30CP002 A160 LO FG
04 ± 0.05 mA for 0 bar
20 ± 0.1 mA for 5 bar (72.5 psi)

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 19/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 22 of 69
SIZE DWG NO SH REV
A4 119T3740 20 C TBFT-TMP-FR-GTE-0060 Rev : 001

MLI Wiring
Devices KKS DEVICE MLI Safety Designation
PID Diagram
Lube oil pressure transmitter downstream VPR2-1
Characteristics : 0 to 5 ± 0,05 VDC
0416 96QH-1 MBV23CP001 A160 LO FG Settings :
04 ± 0.05 mA for 0 bar (0 psi)
20 ± 0.05 mA for 6 bar (87 psi)
Lube oil tank level transmitter
Characteristics : 0.003 kVA | 24 VDC
Settings :
0416 96QL-1 MBV10CL001 A160 LO FG 04 ± 0,1 mA for 760 mm (29.9 in)of floating device stroke
20 ± 04 ± 0,1 mA for 130 mm (5.12 in) of floating device stroke
The stroke of floating device is measured between the flange and
the axis of floating device
Main lube oil filter pressure transmitter
Settings :
0416 96QQ-1 MBV20CP003 A160 LO FG
04 ± 0.05 mA for 0 bar (0 psi)
20 ± 0.05 mA for 5 bar (72.5 psi)
Low lube oil pressure transmitter generator
Settings :
0416 96QT-2A MKV51CP001A ALT. GENE
04 ± 0.05 mA for 0 bar (0 psi)
20 ± 0.05 mA for 2 bar (29 psi)
Low lube oil pressure transmitter generator
Settings :
0416 96QT-2B MKV51CP001B ALT. GENE
04 ± 0.05 mA for 0 bar (0 psi)
20 ± 0.05 mA for 2 bar (29 psi)
Low lube oil pressure transmitter generator
Settings :
0416 96QT-2C MKV51CP001C ALT. GENE
04 ± 0.05 mA for 0 bar (0 psi)
20 ± 0.1 mA for 2 bar (29 psi)
Tank s air vacuum differential pressure transmitter
Settings :
0416 96QV-1 MBV10CP001 A160 LO FG
04 ± 0.05 mA for 0 bar (0 psi)
20 ± 0.1 mA for -40 mbar (-0.58 psi)


Fuel gas stop ratio (VSR) LVDT
0422 96SR-1 MBP70CG021A 0507 LO FG
Settings : 0.7 ± 0.1 V = 0% open | 3.5 ± 0.5 V = 100% open


Fuel gas stop ratio (VSR) LVDT
0422 96SR-2 MBP70CG021B 0507 LO FG
Settings : 0.7 ± 0.1 V = 0% open | 3.5 ± 0.5 V = 100% open
Inlet heating control valve position transmitter
Settings :
0432 96TH-1 MBL70CG001 A037 IBH
20 ± 2 mA = fully closed |
04 ± 2 mA = fully open
Diff press transmitter of total filtration stages
Characteristics : .
0471 96TF-1 MBL20CP001 A040 FILT Settings :
04 ± 0.05 mA for 0 mmH2O (0 inH2O)
20 ± 0.1 mA for 254 mmH2O (10 inH2O)
GT inlet air system differential pressure transmitter
Characteristics :
0471 96TF-2A MBL20CP002A A040 FILT Settings :
04 ± 0.05 mA for 0 mmH2O (0 inH2O)
20 ± 0.1 mA for 254 mmH2O (10 inH2O)
GT inlet air system differential pressure transmitter
Characteristics :
0471 96TF-2B MBL20CP002B A040 FILT Settings :
04 ± 0.05 mA for 0 mmH2O (0 inH2O)
20 ± 0.1 mA for 254 mmH2O (10 inH2O)

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 20/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 23 of 69
SIZE DWG NO SH REV
A4 119T3740 21 C TBFT-TMP-FR-GTE-0060 Rev : 001

MLI Wiring
Devices KKS DEVICE MLI Safety Designation
PID Diagram
Diff press transmitter of coalescer stage
Characteristics : 13 to 36 VCC
0471 96TF-3 MBL20CP003 A040 FILT Settings :
04 ± 0.05 mA for 0 mmH2O (0 inH2O)
20 ± 0.1 mA for 254 mmH2O (10 inH2O)
Diff press transmitter of prefilter & HEF stages
Characteristics :
0471 96TF-4 MBL20CP004 A040 FILT Settings :
04 ± 0.05 mA for 0 mmH2O (0 inH2O)
20 ± 0.1 mA for 152.4 mmH2O (6 inH2O)
Turbine exhaust frame cooling pressure transmitter
Characteristics : Normal : NO
0417 96TK-1 MBH10CP001 A132 AIR Settings :
04 ± 0.05 mA for 0 Pa (0 psi)
20 ± 0.05 mA for 10615 Pa (1.54 psi)
Turbine exhaust frame cooling pressure transmitter
Characteristics : Normal : NO
0417 96TK-2 MBH10CP002 A132 AIR Settings :
04 ± 0.05 mA for 0 Pa (0 psi)
20 ± 0.05 mA for 10615 Pa (1.54 psi)
LVDT (Linear variable displacement transmitter), compressor IGV
0469 96TV-1 MBC20CG001 0548 TURB actuator
Settings : 0.7 ± 0.01 VAC for 25.5° IGV angle
LVDT (Linear variable displacement transmitter), compressor IGV
0469 96TV-2 MBC20CG002 0548 TURB actuator
Settings : 0.7 ± 0.01 VAC for 25.5° IGV angle
Vibration transducer bearing #1
0415 96VC-11 MBD10CY053A 235A TURB Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil)
Settings : Gap : -10.5 ± 0.5 VDC
Vibration transducer bearing #1
0415 96VC-12 MBD10CY053B 235A TURB Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil)
Settings : Gap : -10.5 ± 0.5 VDC
Gas mass flow transmitter
Characteristics : 0.011 kW | 230 UPS
Settings :
Output 1 (HART):

04 ± 0,05 mA for 0 kg/s (0 lbm/s)
0422 96VM-1 MBP50CF002 0639 OTHER
20 ± 0,1 mA for 6,5 kg/s (14.3 lbm/s)
Output 2 (not HART):
04 ± 0,05 mA for 0 kg/s (0 lbm/s)
20 ± 0,1 mA for 1 kg/s (2.2 lbm/s)
Cutoff : 0.1 kg/s
Pressure transmitter for on-line water-wash
Characteristics : 12 to 45 VDC
0442 96WW-1 MBU33CP003 0953 TURB Settings :
04 ± 0.05 mA for 0 bar (0 psi)
20 ± 0.05 mA for 11.4 bar (166 psi)
0469 ACV1-1 MBC20AA201 0548 N/A IGV hydraulic controller assembly
Control oil hydraulic accumulator
0434 AH1-1 MBX20BB001 A160 N/A Characteristics : 17.8 l (4.7 gal) | Nitrogen
Settings : 51.7 ± 1 bar (750 ± 15 psi)
Control oil hydraulic accumulator
0418 AH1-3 MBV40BB001 A160 N/A Characteristics : 2.5 l (0.66 gal) | Nitrogen
Settings : 2 ± 0,1 bar (29 ± 1.5 psi)
Accumulator, hydraulic supply, IGV
0469 AH2-1 MBC20BB001 0908 N/A Characteristics : 5 l (1.32 US Gallon) | Nitrogen
Settings : 41.4 ± 2 bar (600 ± 30 psi)

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 21/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 24 of 69
SIZE DWG NO SH REV
A4 119T3740 22 C TBFT-TMP-FR-GTE-0060 Rev : 001

MLI Wiring
Devices KKS DEVICE MLI Safety Designation
PID Diagram
Generator compartment normal lighting AC voltage"
0403 AL-211 MBV01GZ002-E01 1113 ENCL-T
Characteristics : 2 x 36W | 230 VAC | 50 Hz
Generator compartment normal lighting AC voltage"
0403 AL-212 MBV01GZ002-E02 1113 ENCL-T
Characteristics : 2 x 36W | 230 VAC | 50 Hz
Generator compartment normal lighting AC voltage"
0403 AL-213 MBV01GZ002-E03 1113 ENCL-T
Characteristics : 2 x 36W | 230 VAC | 50 Hz
Generator compartment normal lighting AC voltage"
0403 AL-214 MBV01GZ002-E04 1113 ENCL-T
Characteristics : 2 x 36W | 230 VAC | 50 Hz
Generator compartment normal lighting AC voltage"
0403 AL-215 MBV01GZ002-E05 1113 ENCL-T
Characteristics : 2 x 36W | 230 VAC | 50 Hz
Generator compartment normal lighting AC voltage"
0403 AL-216 MBV01GZ002-E06 1113 ENCL-T
Characteristics : 2 x 36W | 230 VAC | 50 Hz
Generator compartment normal lighting AC voltage"
0403 AL-217 MBV01GZ002-E07 1113 ENCL-T
Characteristics : 2 x 36W | 230 VAC | 50 Hz
Generator compartment normal lighting AC voltage"
0403 AL-218 MBV01GZ002-E08 1113 ENCL-T
Characteristics : 2 x 36W | 230 VAC | 50 Hz
Generator compartment normal lighting AC voltage"
0403 AL-219 MBV01GZ002-E09 1113 ENCL-T
Characteristics : 2 x 36W | 230 VAC | 50 Hz
Generator compartment normal lighting AC voltage"
0403 AL-220 MBV01GZ002-E10 1113 ENCL-T
Characteristics : 2 x 36W | 230 VAC | 50 Hz
Generator compartment normal lighting AC voltage"
0403 AL-221 MBV01GZ002-E11 1113 ENCL-T
Characteristics : 2 x 36W | 230 VAC | 50 Hz
Generator compartment normal lighting AC voltage"
0403 AL-222 MBV01GZ002-E12 1113 ENCL-T
Characteristics : 2 x 36W | 230 VAC | 50 Hz
Lube oil compartment normal lighting AC voltage
0403 AL-271 MBV01GZ001-E01 1137 ENCL-LO
Characteristics : 2 x 36W | 230 VAC | 50 Hz
Lube oil compartment normal lighting AC voltage
0403 AL-272 MBV01GZ001-E02 1137 ENCL-LO
Characteristics : 2 x 36W | 230 VAC | 50 Hz
Lube oil compartment normal lighting AC voltage
0403 AL-273 MBV01GZ001-E03 1137 ENCL-LO
Characteristics : 2 x 36W | 230 VAC | 50 Hz
Lube oil compartment normal lighting AC voltage
0403 AL-274 MBV01GZ001-E04 1137 ENCL-LO
Characteristics : 2 x 36W | 230 VAC | 50 Hz
Electical socket single phase Generator compartment
0403 AR-211 MBV01GZ002-X01 1113 ENCL-T
Characteristics : 16A | 230 VAC
Electical socket single phase Generator compartment
0403 AR-212 MBV01GZ002-X02 1113 ENCL-T
Characteristics : 16A | 230 VAC
Electical socket single phase Generator compartment
0403 AR-213 MBV01GZ002-X03 1113 ENCL-T
Characteristics : 16A | 230 VAC
Electical socket single phase Generator compartment
0403 AR-214 MBV01GZ002-X04 1113 ENCL-T
Characteristics : 16A | 230 VAC
Electical socket single phase exhaust compartment
0403 AR-232 MBL01GZ001-X02 1113 ENCL-T
Characteristics : 16A | 230 VAC
Electical socket single phase load compartment
0403 AR-241 MBJ01GZ001-X01 1113 ENCL-T
Characteristics : 16A | 230 VAC
Electical socket single phase load compartment
0403 AR-242 MBJ01GZ001-X02 1113 ENCL-T
Characteristics : 16A | 230 VAC
Electical socket single phase gas compartment
0403 AR-251 MBP01GZ001-X01 1137 ENCL-LO
Characteristics : 16A | 230 VAC
Electical socket single phase gas compartment
0403 AR-252 MBP01GZ001-X02 1137 ENCL-LO
Characteristics : 16A | 230 VAC

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 22/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 25 of 69
SIZE DWG NO SH REV
A4 119T3740 23 C TBFT-TMP-FR-GTE-0060 Rev : 001

MLI Wiring
Devices KKS DEVICE MLI Safety Designation
PID Diagram
Electical socket single phase gas compartment
0403 AR-253 MBP01GZ001-X03 1137 ENCL-LO
Characteristics : 16A | 230 VAC
Electical socket single phase lube oil compartment
0403 AR-271 MBV01GZ001-X01 1137 ENCL-LO
Characteristics : 16A | 230 VAC
Lighting switch lube oil compartment
0403 ASW-211 MBV01GZ002-S01 1113 ENCL-T
Characteristics : Normal : NO
Lighting switch lube oil compartment
0403 ASW-212 MBV01GZ002-S02 1113 ENCL-T
Characteristics : Normal : NO
Lighting switch lube oil compartment
0403 ASW-213 MBV01GZ002-S03 1113 ENCL-T
Characteristics : Normal : NO
Lighting switch lube oil compartment
0403 ASW-214 MBV01GZ002-S04 1113 ENCL-T
Characteristics : Normal : NO
Lighting switch lube oil compartment
0403 ASW-271 MBV01GZ001-S01 1137 ENCL-LO
Characteristics : Normal : NO
Gas compartment temperature
0436 AT-DLN-1 SAE70CT005 1137 ENCL-LO
Characteristics : Type K
Gas module ventilation duct temperature
0436 AT-DLN-2 SAE70CT006 1634 ENCL-LO
Characteristics : Type K
Air temperature generator compartment
0436 AT-GC-1 SAF10CT001 1113 ENCL-T
Characteristics : Type K
Temperature sensor inside the inlet air filter
0471 AT-ID-1 MBL20CT001 A040 FILT Characteristics : Platinum PT100 | 100 Ohm at 0°C (32°F) | -50 to 260
°C (-58 to 500 °F) | 0.385 Ohm/°C (0.214 Ohm/°F)
Temperature sensor
0471 AT-ID-2 MBL20CT002 A040 FILT Characteristics : Platinum PT100 | 100 Ohm at 0°C (32°F) | -50 to 260
°C (-58 to 500 °F) | 0.385 Ohm/°C (0.214 Ohm/°F)
Temperature sensor
0471 AT-ID-3 MBL20CT003 A040 FILT Characteristics : Platinum PT100 | 100 Ohm at 0°C (32°F) | -50 to 260
°C (-58 to 500 °F) | 0.385 Ohm/°C (0.214 Ohm/°F)
Indoor temperature sensor
0471 AT-ID-4 MBL20CT004 A040 FILT Characteristics : Platinum PT100 | 100 Ohm at 0°C (32°F) | -50 to 260
°C (-58 to 500 °F) | 0.385 Ohm/°C (0.214 Ohm/°F)
Indoor temperature sensor
0471 AT-ID-5 MBL20CT005 A040 FILT Characteristics : Platinum PT100 | 100 Ohm at 0°C (32°F) | -50 to 260
°C (-58 to 500 °F) | 0.385 Ohm/°C (0.214 Ohm/°F)
Indoor temperature sensor
0471 AT-ID-6 MBL20CT006 A040 FILT Characteristics : Platinum PT100 | 100 Ohm at 0°C (32°F) | -50 to 260
°C (-58 to 500 °F) | 0.385 Ohm/°C (0.214 Ohm/°F)
Air temperature load compartment
0436 AT-LC-1 SAE10CT001 1113 ENCL-T
Characteristics : Type K
Lube oil compartment temperature
0436 AT-LO-1 SAE40CT001 1137 ENCL-LO
Characteristics : Type K
Air temperature turbine compartment
0436 AT-TC-1 SAE20CT001 1113 ENCL-T
Characteristics : Type K
Thermocouple : turbine compartment enclosure
0436 AT-TC-2 SAE20CT002 1113 ENCL-T
Characteristics : Type K
Air temperature turbine compartment
0436 AT-TC-4 SAE20CT004 1605 ENCL-T
Characteristics : Type K
Journal bearing #1 dual probe #1 TC #1
0415 BT-J1-1A MBD10CT001A 235A TURB
Characteristics : Type K

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 23/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 26 of 69
SIZE DWG NO SH REV
A4 119T3740 24 C TBFT-TMP-FR-GTE-0060 Rev : 001

MLI Wiring
Devices KKS DEVICE MLI Safety Designation
PID Diagram
Journal bearing #1 dual probe #1 TC #2
0415 BT-J1-1B MBD10CT001B 235A TURB
Characteristics : Type K
Journal bearing #1 dual probe #2 TC #1
0415 BT-J1-2A MBD10CT002A 235A TURB
Characteristics : Type K
Journal bearing #1 dual probe #2 TC #2
0415 BT-J1-2B MBD10CT002B 235A TURB
Characteristics : Type K
Journal bearing #2 dual probe #1 TC #1
0415 BT-J2-1A MBD20CT001A 235B TURB
Characteristics : Type K
Journal bearing #2 dual probe #1 TC #2
0415 BT-J2-1B MBD20CT001B 235B TURB
Characteristics : Type K
Journal bearing #2 dual probe #2 TC #1
0415 BT-J2-2A MBD20CT002A 235B TURB
Characteristics : Type K
Journal bearing #2 dual probe #2 TC #2
0415 BT-J2-2B MBD20CT002B 235B TURB
Characteristics : Type K
0417 B-TK-1 MBH10AN001KN01 A132 AIR Turbine exhaust frame cooling blower
0417 B-TK-2 MBH10AN002KN01 A132 AIR Turbine exhaust frame cooling blower
Dual TC bearing metal on GENshaft bearing on GTside
0495 BT-RGB1-1A MBJ20CT005A A012 LOAD
Characteristics : Type K
Dual TC bearing metal on GENshaft bearing on GTside
0495 BT-RGB1-1B MBJ20CT005B A012 LOAD
Characteristics : Type K
Dual TC bearing metal on GEN shaft by GT side
0495 BT-RGB1-2A MBJ20CT006A A012 LOAD
Characteristics : Type K
Dual TC bearing metal on GEN shaft by GT side
0495 BT-RGB1-2B MBJ20CT006B A012 LOAD
Characteristics : Type K
Dual TC bearing metal on GEN shaft at GEN side
0495 BT-RGB2-1A MBJ20CT007A A012 LOAD
Characteristics : Type K
Dual TC bearing metal on GEN shaft at GEN side
0495 BT-RGB2-1B MBJ20CT007B A012 LOAD
Characteristics : Type K
Dual TC bearing metal on GEN shaft at GEN side
0495 BT-RGB2-2A MBJ20CT008A A012 LOAD
Characteristics : Type K
Dual TC bearing metal on GEN shaft at GEN side
0495 BT-RGB2-2B MBJ20CT008B A012 LOAD
Characteristics : Type K
Dual TC bearing metal at high speed shaft
0495 BT-RGP1-1A MBJ20CT001A A012 LOAD
Characteristics : Type K
Dual TC bearing metal at high speed shaft
0495 BT-RGP1-1B MBJ20CT001B A012 LOAD
Characteristics : Type K
Dual TC bearing metal at high speed shaft
0495 BT-RGP1-2A MBJ20CT002A A012 LOAD
Characteristics : Type K
Dual TC bearing metal at high speed shaft
0495 BT-RGP1-2B MBJ20CT002B A012 LOAD
Characteristics : Type K
Dual TC bearing metal at high speed shaft
0495 BT-RGP2-1A MBJ20CT003A A012 LOAD
Characteristics : Type K
Dual TC bearing metal at high speed shaft
0495 BT-RGP2-1B MBJ20CT003B A012 LOAD
Characteristics : Type K
Dual TC bearing metal at high speed shaft
0495 BT-RGP2-2A MBJ20CT004A A012 LOAD
Characteristics : Type K
Dual TC bearing metal at high speed shaft
0495 BT-RGP2-2B MBJ20CT004B A012 LOAD
Characteristics : Type K

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 24/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 27 of 69
SIZE DWG NO SH REV
A4 119T3740 25 C TBFT-TMP-FR-GTE-0060 Rev : 001

MLI Wiring
Devices KKS DEVICE MLI Safety Designation
PID Diagram
Thermocouple pad n°12 of counter thrust bearing n°1
0415 BT-TA-12A MBD10CT005A 235A TURB
Characteristics : Type K
Thermocouple pad n°12 of counter thrust bearing n°1
0415 BT-TA-12B MBD10CT005B 235A TURB
Characteristics : Type K
Thermocouple pad n°6 of thrust bearing n°1
0415 BT-TA-6A MBD10CT006A 235A TURB
Characteristics : Type K
Thermocouple pad n°6 of thrust bearing n°1
0415 BT-TA-6B MBD10CT006B 235A TURB
Characteristics : Type K
Thermocouple pad n°4 of counter thrust bearing n°1
0415 BT-TI-4A MBD10CT007A 235A TURB
Characteristics : Type K
Thermocouple pad n°4 of counter thrust bearing n°1
0415 BT-TI-4B MBD10CT007B 235A TURB
Characteristics : Type K
Thermocouple pad n°8 of thrust bearing n°1
0415 BT-TI-8A MBD10CT008A 235A TURB
Characteristics : Type K
Thermocouple pad n°8 of thrust bearing n°1
0415 BT-TI-8B MBD10CT008B 235A TURB
Characteristics : Type K
Thermocouple compressor air discharge temperature
0415 CT-DA-1 MBC15CT001 0637 TURB
Characteristics : Type K
Thermocouple compressor air discharge temperature
0415 CT-DA-2 MBC15CT002 0637 TURB
Characteristics : Type K
Thermocouple temperature air outlet of compressor
0415 CT-DA-3 MBC15CT003 0637 TURB
Characteristics : Type K
Thermocouple temperature compressor air inlet
0415 CT-IF-1A MBC10CT001A 0637 TURB
Characteristics : Type K
Thermocouple temperature compressor air inlet
0415 CT-IF-1B MBC10CT001B 0637 TURB
Characteristics : Type K
Thermocouple temperature compressor air inlet
0415 CT-IF-2A MBC10CT002A 0637 TURB
Characteristics : Type K
Thermocouple temperature compressor air inlet
0415 CT-IF-2B MBC10CT002B 0637 TURB
Characteristics : Type K
Resistance temperature detector
0492 CT-IF-3/R MBL90CT003 0637 TURB Characteristics : Platinum PT100 | 100 Ohm at 0°C (32 °F) | -50 to 260
°C (-58 to 500 °F) | 0.385 Ohm/°C (0.214 Ohm/°F)
Generator compartment safety floodlight DC voltage"
0403 DL-211 MBV01GZ002-E13 1113 ENCL-T
Characteristics : 80W | 125 VDC
Generator compartment safety floodlight DC voltage"
0403 DL-212 MBV01GZ002-E14 1113 ENCL-T
Characteristics : 80W | 125 VDC
Generator compartment safety floodlight DC voltage"
0403 DL-213 MBV01GZ002-E15 1113 ENCL-T
Characteristics : 80W | 125 VDC
Generator compartment safety floodlight DC voltage"
0403 DL-214 MBV01GZ002-E16 1113 ENCL-T
Characteristics : 80W | 125 VDC
Generator compartment safety floodlight DC voltage"
0403 DL-215 MBV01GZ002-E17 1113 ENCL-T
Characteristics : 80W | 125 VDC
Generator compartment safety floodlight DC voltage"
0403 DL-216 MBV01GZ002-E18 1113 ENCL-T
Characteristics : 80W | 125 VDC
Generator compartment safety floodlight DC voltage"
0403 DL-217 MBV01GZ002-E19 1113 ENCL-T
Characteristics : 80W | 125 VDC
Generator compartment safety floodlight DC voltage"
0403 DL-218 MBV01GZ002-E20 1113 ENCL-T
Characteristics : 80W | 125 VDC

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 25/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 28 of 69
SIZE DWG NO SH REV
A4 119T3740 26 C TBFT-TMP-FR-GTE-0060 Rev : 001

MLI Wiring
Devices KKS DEVICE MLI Safety Designation
PID Diagram
Turbine compartment safety floodlight DC voltage
0403 DL-221 MBA01GZ001-E11 1113 ENCL-T
Characteristics : 80W | 125 VDC
Turbine compartment safety floodlight DC voltage
0403 DL-222 MBA01GZ001-E12 1113 ENCL-T
Characteristics : 80W | 125 VDC
Exhaust compartment safety floodlight DC voltage
0403 DL-231 MBL01GZ001-E11 1113 ENCL-T
Characteristics : 80W | 125 VDC
Exhaust compartment safety floodlight DC voltage
0403 DL-232 MBL01GZ001-E12 1113 ENCL-T
Characteristics : 80W | 125 VDC
Load compartment safety floodlight DC voltage
0403 DL-241 MBJ01GZ001-E11 1113 ENCL-T
Characteristics : 80W | 125 VDC
Load compartment safety floodlight DC voltage
0403 DL-242 MBJ01GZ001-E12 1113 ENCL-T
Characteristics : 80W | 125 VDC
Gas compartment safety floodlight DC voltage
0403 DL-251 MBP01GZ001-E11 1137 ENCL-LO
Characteristics : 80W | 125 VDC
Gas compartment safety floodlight DC voltage
0403 DL-252 MBP01GZ001-E12 1137 ENCL-LO
Characteristics : 80W | 125 VDC
Gas compartment safety floodlight DC voltage
0403 DL-253 MBP01GZ001-E13 1137 ENCL-LO
Characteristics : 80W | 125 VDC
Lube oil compartment safety floodlight DC voltage
0403 DL-271 MBV01GZ001-E11 1137 ENCL-LO
Characteristics : 80W | 125 VDC
0436 DV101 SAE11AA001 1605 N/A Damper of F-VG-1
0436 DV102 SAE18AA001 1605 N/A Load Compartment ventilation fan damper (Exhaust 88VG-1)
0436 DV111 SAE12AA001 1605 N/A Damper of F-VG-2
0436 DV112 SAE18AA002 1605 N/A Load Compartment ventilation fan damper (Exhaust 88VG-2)
0436 DV151 SAE27AA001 1605 N/A Damper of F-BT-1
0436 DV161 SAE28AA001 1605 N/A Damper of F-BT-2
0436 DV201 SAE70AA001 1634 N/A Gas compartment inlet damper
0436 DV211 SAE71AA001 1634 N/A Damper of F-VL-1
0436 DV221 SAE72AA001 1634 N/A Damper of F-VL-2
0436 DV231 SAE41AA001 1634 N/A BL-1 lubel oil compartment inlet damper
0436 DV241 SAE42AA001 1634 N/A BL-2 lube oil compartment inlet damper
0436 DV251 SAE48AA001 1634 N/A Lube oil compartment outlet damper
0436 DV350 SAF11AA001 266 N/A Generator compartment air outlet damper
0436 DV351 SAF12AA001 266 N/A Generator compartment air outlet damper
0436 DV501 SAE20AA011 1605 N/A GT compartment inlet damper
0436 DV502 SAE20AA012 1605 N/A GT compartment inlet damper
0474 FAGD-1 CYQ10AT001 0585 N/A Filter for ventilation air flow gas turbine enclosure
0474 FAGD-2 CYQ10AT002 0585 N/A Filter for ventilation air flow gas turbine enclosure
0474 FAGD-4 CYQ10AT004 0585 N/A Filter for ventilation air flow gas turbine enclosure
0474 FAGD-5 CYQ10AT005 0585 N/A Filter for ventilation air flow gas turbine enclosure
0474 FAGD-8 CYQ11AT001 0585 N/A Filter for ventilation air flow gas turbine enclosure
0474 FAGD-9 CYQ11AT002 0585 N/A Filter for ventilation air flow gas turbine enclosure
0416 FB1-1 MBV11AN001KN01 A160 N/A Oil Mist Blower with motor 88QV-1A
0416 FB2-1 MBV11AN002KN01 A160 N/A Oil Mist Blower with motor 88QV-1B

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 26/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 29 of 69
SIZE DWG NO SH REV
A4 119T3740 27 C TBFT-TMP-FR-GTE-0060 Rev : 001

MLI Wiring
Devices KKS DEVICE MLI Safety Designation
PID Diagram
0436 F-BL-1 SAE41AN001KN01 1634 N/A Lube oil compartment cooling air fan BL-1
0436 F-BL-2 SAE42AN001KN01 1634 N/A Lube oil compartment cooling air fan BL-2
0417 F-BN-1 MBH15AN001KN01 A132 AIR 2nd bearing cooling fan
0417 F-BN-2 MBH15AN002KN01 A132 AIR 2nd bearing cooling fan
0436 F-BT-1 SAE27AN001KN01 1605 N/A GT compartment ventilation fan BT-1
0436 F-BT-2 SAE28AN001KN01 1605 N/A GT compartment ventilation fan BT-2
Gas supply filter
0422 FG-1 MBP70AT002 0929 N/A
Characteristics : 150 µm
Instrumentation gas filter
0422 FG-2 MBP68AT002 G064 N/A
Characteristics : 60 µm
Hydraulic oil supply filter
0434 FH2-1 MBX11AT001 1051 N/A
Characteristics : Beta 3 > 200
Hydraulic oil supply filter
0434 FH2-2 MBX12AT001 1051 N/A
Characteristics : Beta 3 > 200
Filter, hydraulic fluid supply , IGV controller assembly
0469 FH6-1 MBC20AT001 0548 N/A
Characteristics : Beta 15 = 75
Servo hydraulic supply filter of stop ratio valve (VSR)
0422 FH7-1 MBP70AT021 0507 N/A
Characteristics : Beta 15 = 75
Gas fuel control servo hydraulic fluid supply filter
0422 FH8-1 MBP71AT011 0509 N/A
Characteristics : Beta 15 = 75
Gas fuel control servo hydraulic fluid supply filter
0422 FH8-2 MBP72AT011 0509 N/A
Characteristics : Beta 15 = 75
Gas fuel control servo hydraulic fluid supply filter
0422 FH8-3 MBP73AT011 0509 N/A
Characteristics : Beta 15 = 75
Gas fuel control servo hydraulic fluid supply filter
0422 FH8-4 MBP74AT011 0509 N/A
Characteristics : Beta 15 = 75
Fuel gas temperature sensor
0422 FT-GI-1A MBP70CT003A A160 LO FG
Characteristics : Type K
Fuel Gas Temperature Sensor
0422 FT-GI-1B MBP70CT003B A160 LO FG
Characteristics : Type K
Fuel Gas Temperature Sensor
0422 FT-GI-2A MBP70CT004A A160 LO FG
Characteristics : Type K
Fuel Gas Temperature Sensor
0422 FT-GI-2B MBP70CT004B A160 LO FG
Characteristics : Type K
0436 F-VG-1 SAE11AN001KN01 1605 N/A Load compartment centrifugal ventilation fan
0436 F-VG-2 SAE12AN001KN01 1605 N/A Load compartment centrifugal ventilation fan
0436 F-VL-1 SAE71AN001KN01 1634 N/A Gas Compartment Ventilation Fan/Blower with motor 88VL-1
0436 F-VL-2 SAE72AN001KN01 1634 N/A Gas Compartment Ventilation Fan/Blower with motor 88VL-2
0436 F-GV-1 SAF11 AN001-KN01 266 N/A Generator compartment Fan/Blower with motor 88GV-1
0436 F-GV-2 SAF12 AN001-KN01 266 N/A Generator compartment Fan/Blower with motor 88GV-2
Actuator assembly, inlet guide valve system
0469 HM3-1 MBC20AA002 0548 N/A Characteristics : Actuator stroke : 25.5 ± 0.5 IGV degree to 91.5 ± 0.5
IGV degree
Lube oil coalescing filter
0416 LF3-3 MBV11AT001 A160 N/A
Characteristics : Beta40 = 75
0416 LI-QH-1 MBV10CL501 A160 N/A Lube oil tank level visual indicator

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 27/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 30 of 69
SIZE DWG NO SH REV
A4 119T3740 28 C TBFT-TMP-FR-GTE-0060 Rev : 001

MLI Wiring
Devices KKS DEVICE MLI Safety Designation
PID Diagram
Lube oil filter
0416 LOF1-1 MBV22AT002 1010 N/A
Characteristics : Beta 40 = 75
Lube oil filter
0416 LOF1-2 MBV22AT002 1010 N/A
Characteristics : Beta 40 = 75
0416 LOHX-1 MBV21AH001 1001 N/A Lube oil cooler
0416 LOHX-2 MBV22AH001 1001 N/A Lube oil cooler
0416 LO-TK-1 MBV10BB001 A160 N/A Lube Oil Tank
Lube oil thermocouple #1 bearing drain
0416 LT-B1D-1A MBV51CT001A 557T TURB
Characteristics : Type K
Lube oil thermocouple #1 bearing drain
0416 LT-B1D-1B MBV51CT001B 557T TURB
Characteristics : Type K
Lube oil thermocouple #2 bearing drain
0416 LT-B2D-1A MBV52CT001A 557T TURB
Characteristics : Type K
Lube oil thermocouple #2 bearing drain
0416 LT-B2D-1B MBV52CT001B 557T TURB
Characteristics : Type K
LO TC generator and load gear #1 bearing drain
0416 LT-G1D-1 MKV51CT001 ALT. GENE
Characteristics : Type K
LO TC generator and load gear #2 bearing drain
0416 LT-G2D-1 MKV52CT002 ALT. GENE
Characteristics : Type K
Temperature in oil tank detector
0416 LT-OT-1 MBV10CT001 A160 LO FG
Characteristics : Type K
Resistance temperature in oil tank detector
0416 LT-OT-2 MBV10CT004 A160 LO FG
Characteristics : Type K
Load gear lube oil drain temperature
0495 LT-RG-1D MBJ20CT009 A012 LOAD
Characteristics : Type K
Load gear lube oil drain temperature
0495 LT-RG-2D MBJ20CT010 A012 LOAD
Characteristics : Type K
Lube oil temperature turbine header thermocouple
0416 LT-TH-1 MBV23CT001 A160 LO FG
Characteristics : Type K
Lube oil temperature turbine header thermocouple
0416 LT-TH-2 MBV23CT002 A160 LO FG
Characteristics : Type K
Lube oil temperature turbine header thermocouple
0416 LT-TH-3 MBV23CT003 A160 LO FG
Characteristics : Type K
Main hydraulic supply pump
0434 PH1-1 MBX11AP001 0627 N/A Characteristics : Volumetric variable flow | 110 bar max (1595 psi
max) | 52 l/min max (14 gpm max)
Main hydraulic supply pump
0434 PH2-1 MBX12AP001 0627 N/A Characteristics : Volumetric variable flow | 110 bar max (1595 psi
max) | 52 l/min max (14 gpm max)
Lube oil main pump
0416 PQ1-1 MBV20AP001 1005 N/A Characteristics : Centrifugal pump | 2950 rpm | 5.3 bar (76.9 psi) |
3600 l/min (951 gpm)
Lube oil main pump
0416 PQ1-2 MBV20AP002 1005 N/A Characteristics : Centrifugal pump | 2950 rpm | 5.3 bar (76.9 psi) |
3600 l/min (951 gpm)
Lube oil emergency pump
0416 PQ2-1 MBV30AP001 1007 N/A Characteristics : Centrifugal pump | 2970 rpm | 2.5 bar (36.3 psi) |
2178 l/min (575 gpm)
Hydraulic accumulator relief valve
0434 PSV500 MBX20AA902 A160 N/A Characteristics : Normal : NC
Settings : 300 bar ± 1 bar (4351 ± 15 psi)

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 28/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 31 of 69
SIZE DWG NO SH REV
A4 119T3740 29 C TBFT-TMP-FR-GTE-0060 Rev : 001

MLI Wiring
Devices KKS DEVICE MLI Safety Designation
PID Diagram
Hydraulic accumulator relief valve
0418 PSV800 MBV40AA901 A160 N/A Characteristics : Normal : NC
Settings : 80 bar ± 1 bar (1160 ± 15 psi)
Fire alarm
0426 SLI-1A SGJ70EG001 1113 ENCL-T
Characteristics : Visual alarm | 24 VDC
Fire alarm
0426 SLI-1B SGJ10EG002A 1113 ENCL-T
Characteristics : Visual alarm | 24 VDC
Fire alarm
0426 SLI-1C SGJ10EG002B 1113 ENCL-T
Characteristics : Visual and audible alarm | 24 VDC
Fire alarm
0426 SLI-1D SGJ50EG009 1137 ENCL-LO
Characteristics : Visual alarm | 24 VDC
Fire alarm
0426 SLI-1E SGJ50EG010 1137 ENCL-LO
Characteristics : Visual and audible alarm | 24 VDC
Fire alarm
0426 SLI-2B SGJ10EG003A 1113 ENCL-T
Characteristics : Visual alarm | 24 VDC
Fire alarm
0426 SLI-2C SGJ10EG003B 1113 ENCL-T
Characteristics : Visual and audible alarm | 24 VDC
Fire alarm
0426 SLI-2D SGJ50EG002A 1137 ENCL-LO
Characteristics : Visual alarm | 24 VDC
Fire alarm
0426 SLI-2E SGJ50EG008 1137 ENCL-LO
Characteristics : Visual and audible alarm | 24 VDC
Thermocouple temperature exhaust tunnel
0415 TT-IB-1 MBB50CT001 0637 TURB
Characteristics : Type K
Thermocouple temperature exhaust tunnel
0415 TT-IB-2 MBB50CT002 0637 TURB
Characteristics : Type K
Thermocouple temperature exhaust tunnel
0415 TT-IB-3 MBB50CT003 0637 TURB
Characteristics : Type K
TC wheelspace outer position after first wheel
0415 TT-WS1AO-1 MBB31CT001 0637 TURB
Characteristics : Type K
TC wheelspace outer position after first wheel
0415 TT-WS1AO-2 MBB31CT002 0637 TURB
Characteristics : Type K
TC wheelspace inner position forward first wheel
0415 TT-WS1FI-1 MBB31CT003 0637 TURB
Characteristics : Type K
TC wheelspace inner position forward first wheel
0415 TT-WS1FI-2 MBB31CT004 0637 TURB
Characteristics : Type K
TC wheelspace outer position after second wheel
0415 TT-WS2AO-1 MBB32CT001 0637 TURB
Characteristics : Type K
TC wheelspace outer position after second wheel
0415 TT-WS2AO-2 MBB32CT002 0637 TURB
Characteristics : Type K
TC wheelspace outer position after third wheel
0415 TT-WS3AO-1 MBB33CT001 0637 TURB
Characteristics : Type K
TC wheelspace outer position after third wheel
0415 TT-WS3AO-2 MBB33CT002 0637 TURB
Characteristics : Type K


Thermocouple temperature of GT exhaust
0415 TT-XD-1 MBR10CT001X 0623 TURB
Characteristics : Type K


Thermocouple temperature of GT exhaust
0415 TT-XD-10 MBR10CT010 0623 TURB
Characteristics : Type K


Thermocouple temperature of GT exhaust
0415 TT-XD-11 MBR10CT011 0623 TURB
Characteristics : Type K

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 29/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 32 of 69
SIZE DWG NO SH REV
A4 119T3740 30 C TBFT-TMP-FR-GTE-0060 Rev : 001

MLI Wiring
Devices KKS DEVICE MLI Safety Designation
PID Diagram


Thermocouple temperature of GT exhaust
0415 TT-XD-12 MBR10CT012 0623 TURB
Characteristics : Type K


Thermocouple temperature of GT exhaust
0415 TT-XD-13 MBR10CT013 0623 TURB
Characteristics : Type K


Thermocouple temperature of GT exhaust
0415 TT-XD-14 MBR10CT014 0623 TURB
Characteristics : Type K


Thermocouple temperature of GT exhaust
0415 TT-XD-15 MBR10CT015 0623 TURB
Characteristics : Type K


Thermocouple temperature of GT exhaust
0415 TT-XD-16 MBR10CT016 0623 TURB
Characteristics : Type K


Thermocouple temperature of GT exhaust
0415 TT-XD-17 MBR10CT017 0623 TURB
Characteristics : Type K


Thermocouple temperature of GT exhaust
0415 TT-XD-18 MBR10CT018 0623 TURB
Characteristics : Type K


Thermocouple temperature of GT exhaust
0415 TT-XD-19 MBR10CT019 0623 TURB
Characteristics : Type K


Thermocouple temperature of GT exhaust
0415 TT-XD-2 MBR10CT002 0623 TURB
Characteristics : Type K


Thermocouple temperature of GT exhaust
0415 TT-XD-20 MBR10CT020 0623 TURB
Characteristics : Type K


Thermocouple temperature of GT exhaust
0415 TT-XD-21 MBR10CT021 0623 TURB
Characteristics : Type K


Thermocouple temperature of GT exhaust
0415 TT-XD-3 MBR10CT003 0623 TURB
Characteristics : Type K


Thermocouple temperature of GT exhaust
0415 TT-XD-4 MBR10CT004 0623 TURB
Characteristics : Type K


Thermocouple temperature of GT exhaust
0415 TT-XD-5 MBR10CT005 0623 TURB
Characteristics : Type K


Thermocouple temperature of GT exhaust
0415 TT-XD-6 MBR10CT006 0623 TURB
Characteristics : Type K


Thermocouple temperature of GT exhaust
0415 TT-XD-7 MBR10CT007 0623 TURB
Characteristics : Type K


Thermocouple temperature of GT exhaust
0415 TT-XD-8 MBR10CT008 0623 TURB
Characteristics : Type K


Thermocouple temperature of GT exhaust
0415 TT-XD-9 MBR10CT009 0623 TURB
Characteristics : Type K


Gas fuel system intervalve cavity vent valve
0422 VA13-15 MBP70AA230 A160 N/A
Characteristics : Normal : FO


Gas fuel circuit vent valve
0422 VA13-18 MBP68AA220 G064 N/A
Characteristics : Normal : FO
Pneumatic ball valve for off-line compressor WW
0442 VA16-1 MBU33AA201 0953 N/A
Characteristics : Normal : FC
Pneumatic ball valve for on-line compressor WW
0442 VA16-3 MBU33AA202 0953 N/A
Characteristics : Normal : FC
False start drain valve
0442 VA17-1 MBU41AA202 1026 N/A
Characteristics : Normal : FO
False start drain valve
0442 VA17-2 MBU42AA202 1026 N/A
Characteristics : Normal : FO
False start drain valve
0442 VA17-6A MBU44AA201 1026 N/A
Characteristics : Normal : FO

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 30/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 33 of 69
SIZE DWG NO SH REV
A4 119T3740 31 C TBFT-TMP-FR-GTE-0060 Rev : 001

MLI Wiring
Devices KKS DEVICE MLI Safety Designation
PID Diagram
False start drain valve
0442 VA17-6B MBU45AA201 1026 N/A
Characteristics : Normal : FO
False start drain valve
0442 VA17-7 MBU46AA201 1026 N/A
Characteristics : Normal : FO
Inlet heating control valve
0432 VA20-1 MBL70AA202 A037 N/A
Characteristics : Normal : FO
Compressor bleed valve
0417 VA2-1 MBH21AA201 1022 N/A
Characteristics : Normal : NO
Compressor bleed valve
0417 VA2-2 MBH22AA201 1022 N/A
Characteristics : Normal : NO
Compressor bleed valve
0417 VA2-3 MBH23AA201 1022 N/A
Characteristics : Normal : NO
Compressor bleed valve
0417 VA2-4 MBH24AA201 1022 N/A
Characteristics : Normal : NO
Cooling water control valve - lube oil
0420 VA32-1 MBE32AA211 A160 N/A Characteristics : Normal : L to R open, B closed
Settings : Oil T° = 54.4 ± 2°C (130 ± 3.6°F)


Quick exhaust pneumatic valve of actuator air
0422 VA36-61 MBP68AA210D G064 N/A
Characteristics : Normal : FO


Quick exhaust pneumatic valve of actuator air
0422 VA36-62 MBP68AA220D G064 N/A
Characteristics : Normal : FO
Vol booster valve for regulation bleedheating valve
0432 VA40-1 MBL70AA204 A037 N/A
Characteristics : Normal : NO
Inlet bleed heat valve VA20-1 quick exhauster valve
0432 VA42-1 MBL70AA205 A037 N/A
Characteristics : Normal : NO
0434 VAB1-1 MBX11AA201 0627 N/A Hydraulic system air bleed valve
0434 VAB1-2 MBX12AA203 0627 N/A Hydraulic system air bleed valve
Oil mist eliminator blower check valve
0416 VCK20-1 MBV11AA003 A098 N/A
Characteristics : Normal : NC
Iil mist eliminator blower check valve
0416 VCK20-11 MBV11AA005 A098 N/A
Characteristics : Normal : NC
Lube oil mist eliminator check valve
0416 VCK20-13 MBV11AA007 A098 N/A
Characteristics : Normal : NC
Lube oil pump (PQ1-1) check valve
0416 VCK20-14 MBV20AA101 A160 N/A
Characteristics : Normal : NC
Lube oil pump (PQ1-2) check valve
0416 VCK20-15 MBV20AA102 A160 N/A
Characteristics : Normal : NC
Lube oil pump (PQ2-1) check valve
0416 VCK20-16 MBV30AA101 A160 N/A
Characteristics : Normal : NC
VCK for maintenance valve (N2)
0422 VCK302 MBP68AA108 A160 N/A
Characteristics : Normal : NC
Hydraulic pump check valve for main pump
0434 VCK3-1 MBX11AA001 0627 N/A
Characteristics : Normal : NC
Hydraulic pump check valve for auxiliary pump
0434 VCK3-2 MBX12AA001 0627 N/A
Characteristics : Normal : NC
Check Valve hydraulic circuit
0469 VCK3-7 MBC20AA101 0548 N/A
Characteristics : Normal : NC
Hydraulic filter check valve
0434 VCK4-1 MBX11AA006 A160 N/A
Characteristics : Normal : NC

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 31/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 34 of 69
SIZE DWG NO SH REV
A4 119T3740 32 C TBFT-TMP-FR-GTE-0060 Rev : 001

MLI Wiring
Devices KKS DEVICE MLI Safety Designation
PID Diagram
Hydraulic filter check valve
0434 VCK4-2 MBX12AA002 A160 N/A
Characteristics : Normal : NC
Turbine exhaust frame cooling check valve
0417 VCK7-1 MBH10AA110 0969 N/A
Characteristics : Normal : NC
Turbine exhaust frame cooling check valve
0417 VCK7-2 MBH10AA001 0969 N/A
Characteristics : Normal : NC
2nd bearing cooling blower check valve
0417 VCK7-3 MBH15AA110 0969 N/A
Characteristics : Normal : NC
2nd bearing cooling blower check valve
0417 VCK7-4 MBH15AA001 0969 N/A
Characteristics : Normal : NC


Gas control valve
0422 VGC-1 MBP71AA210 0509 N/A
Characteristics : Stroke maxi = 38.1 mm (1.5 in) | Normal : FC


Gas control valve
0422 VGC-2 MBP72AA210 0509 N/A
Characteristics : Stroke maxi = 38.1 mm (1.5 in) | Normal : FC


Gas control valve
0422 VGC-3 MBP73AA210 0509 N/A
Characteristics : Stroke maxi = 38.1 mm (1.5 in) | Normal : FC


Gas control valve
0422 VGC-4 MBP74AA210 0509 N/A
Characteristics : Stroke maxi = 38.1 mm (1.5 in) | Normal : FC
FG circuit vent valve during start up (gas heat)
0422 VGV-10 MBP70AA290 A160 N/A
Characteristics : Normal : FO
Trip relay, hydraulic IGV
0469 VH3-1 MBC20AA202 0548 N/A
Characteristics : Normal : NC


Gas fuel dump valve VSR-1 valve
0422 VH5-1 MBP70AA220A 0507 N/A
Characteristics : Normal : NC


Gas fuel dump valve VGC-1 valve
0422 VH5-2 MBP71AA210A 0509 N/A
Characteristics : Normal : NC


Gas fuel dump valve VGC-2 valve
0422 VH5-3 MBP72AA210A 0509 N/A
Characteristics : Normal : NC


Gas fuel dump valve VGC-3 valve
0422 VH5-4 MBP73AA210A 0509 N/A
Characteristics : Normal : NC


Gas fuel dump valve VGC-4 valve
0422 VH5-5 MBP74AA210A 0509 N/A
Characteristics : Normal : NC
0422 VM-1 MBP50CF003 0639 N/A  Coriolis mass flow meter
Inlet heating isolation valve
0432 VM15-1 MBL70AA101 A037 N/A
Characteristics : Normal : NO
0434 VM4-1 MBX11AA002 1051 N/A Hydraulic filter transfer valve
Pressure regulating valve
0422 VPR-1 MBP68AA601 G064 N/A Characteristics : Normal : NC
Settings : 8 ± 0.5 bar (116 ± 7 psi)
Bearing header pressure regulator valve
0416 VPR2-1 MBV23AA601 1023 N/A Characteristics : Normal : NC
Settings : 1.72 +0.13/-0 bar (25 +2/-0 psi)
Hydraulic supply pump (PH1) compensator
0434 VPR3-1 MBX11AP001KA01 0627 N/A
Settings : 82.7 ± 1.72 bar (1200 ± 25 psi)
Hydraulic supply pump (PH2) compensator
0434 VPR3-2 MBX12AP001KA01 0627 N/A
Settings : 82.7 ± 1.72 bar (1200 ± 25 psi)
Filter regulator for control valve bleed heating
0432 VPR41-1 MBL70AA601 A037 N/A
Settings : 3.10 ± 0.14 bar (45 ± 2 psi)
Press regulating filter instrument air valve VA32-2
0420 VPR64-2 MBE32AA601 1035 N/A
Settings : 5.2 ± 0.2 bar (75 ± 3 psi)

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 32/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.
Il ne peut être communiqué, copié ou reproduit sans notre autorisation écrite préalable. It must not be communicated, copied or reproduced without our previous written consent.

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 119T3740 REV C Released 2016/11/23 Page 35 of 69
SIZE DWG NO SH REV
A4 119T3740 33 C TBFT-TMP-FR-GTE-0060 Rev : 001

MLI Wiring
Devices KKS DEVICE MLI Safety Designation
PID Diagram
On-line water-wash regulator valve
0442 VPR80-1 MBU33AA602 0953 N/A
Settings : Downstream pressure : 5.5 ± 0.27 bar (80 ± 4 psi)
Hydraulic oil supply pump PH1-1 press relief valve
0434 VR21-1 MBX11AA901 0627 N/A Characteristics : Normal : NC
Settings : 92.7 ± 1.76 bar (1345 ± 25 psi)
Hydraulic oil supply pump PH1-1 press relief valve
0434 VR22-1 MBX12AA901 0627 N/A Characteristics : Normal : NC
Settings : 92.7 ± 1.76 bar (1345 ± 25 psi)
Pressure relief valve, accumulator safety block
0469 VR81-21 MBC20AA901 0908 N/A Characteristics : Normal : NC
Settings : 300 bar ± 1 bar (4351 ± 15 psi)
Safety relief valve
0422 VR9-1 MBP68AA901 G064 N/A Characteristics : Normal : NC
Settings : 10 ± 0,5 bar (145 ± 7 psi)


Gas stop valve
0422 VS4-4 MBP68AA210 G064 N/A
Characteristics : normal : FC
Fuel gas stop/speed ratio valve
0422 VSR-1 MBP70AA220 0507 N/A  Characteristics : Stroke maxi = 88.9 ± 0.127 mm (3.5 ± 0.05 in) |
Normal : FC

SIZE CAGE CODE DWG NO


119T3740
A4

SECTION 01EN
SCALE SHEET 33/ 33
Doc. Source : TBFT-ISP-FR-GTE-0020
Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel This document, exclusive property of GE Energy Products France SNC. is strictly confidential.