Вы находитесь на странице: 1из 18

The Kim EKG is an investment in energy-efficient,

trouble-f ree outdoor lighting.


lntroduced in 1972, the EKG of time and the outdoor and ballast technology. In new Catalog Organization
fixture has become a standard environment. This luminaire is construction or retrofit, for Product Overview 2
for longevity, performance and built to last, as more than a lighting roadways, parking lots Performance Efficiency 3
quality. Thousands of EKG decade of onthe-job or open areas. the only time- Optical Design 4
luminaires installed all over the performance has proven. With proven choice is the Kim EKG. lnstallation & Adaptability 5
world are testimony to the fact the EKG/Generation 2 high ManufacturingProcedures 6
that true quality pays for itself . light output is maintained as The Final Test 7
Architects, landscape conslstently as physical Mounting Options 8-9
architects, lighting designers, appearance. ln addition, the Details & Specifications 10-11
engineers and owners have fixture is engineered to EKG Catalogs: Ordering lnformation 12-14
selected the Kim EKG to accommodate, with only minor A1 Fixtures
complement buildings and component changes, A2 Photometrics
sites that must stand the rrgors anticipated advances in lamp A3 Templates

t
1t
,q

3:t
ffi

ffi
Performance
and quality
are the
long-term
return on your
investment.

1
Performance Maintained light Rapid installation, Materials and
designed for output through sealed easy maintenance, construction
application efficiency. optics. and adaptability to designed for
The true tesl of any lumira re is Coupled with app ication new technology. longevity.
how well it will perform in a effrciency is the ability to "Time js moneyl' a truism From raw materials, to
spec f c instal alion. Al Kim. we marntain ght output on the site. substantiated by today's high construction methods, to final
ca this appllcatlon eff crency. After all, n tial light output is of labor costs. Whether on initial coatings. there are no
Pole spacing, tota watts per litt e consequence if rt cannot installation or periodic compromises in the production
square foot, uniformity of light, be sustained over the years in maintenance, a fixture of an EKG. lt must withstand
and vis b iity are the factors to an outdoor envi ronment, designed specifically for ease wind, rain, snow, lce, wide
consider in evaluating an Performance or ented frxtures of handling is a time and temperature variatron, bugs,
outdoor luminaire. The EKG has lose eff icrency and waste money-saving asset. The entire dlrt, polluted air, and vandailsm
been des gned to provide true energy when optical chambers EKG fixture is constructed in throughout its useful ife. There
"bottom line" efficiency. As are f lled wlth dirt and insects. self-contai ned sub-assemblies is no harsher environment than
evidence, a computer analysis A comp etely sealed optical that provide for quick the outdoors, and only the best
can be prov ded by the Kim cha^lber was a [orenosl i nstallation and maintenance. materials coupled with proven
Lighting Application consideration in the conception Far-sighted engineering allows construction methods can
Department. ano design oi tl-e EKG. Ire these sub-assemblies to easily stand the test of time. Kim's
results of th s effort are readi y adapt to new developments in 50 years of exper ence in th-o
apparent when comparing the lamp and ballast technology, outdoor lighting business is the
Kim EKG with competitive keeping the EKG operating at basis fo' his ptr l6s6p6t
lumlnaires after several years peak efficiency. There is no
of fie d operat on. The EKG ls reason for an EKG to ever
always substantially cleaner become obsolete.
than any other fixture of
comparable age.

A1-2
Performance Fcr roadwav ignlrng tre
1 designed for nI tKG tras been designed ro
provide near uniform coverage
appl ication eff iciency. f rom curb to curb. Typ cal
street widths range f rom 1 to 2
See catalog 42 for complete mounting he ghts, and the EKG
photometncs and quick wi provide v rtually the same
reference charts. light leve1 f rom the near curb
directly across to the far curb
In addition, houses de ight
leve s reman strong n back
of the curb far enough to
ght sidewalks.

El
A
Parhino lot liohtlno
"^^,, rc-
rsvu -xi^,,^I.ieSOt
"^"^ gr rr 9uailr
--!,,1:
"A" pius a strong thrust of llght
at the 45'ang es. This diagonal
,li::ir,'r.,,,,...... A i uminat on means substantia y
greater po e spacings because
B the ight level at the midpoint
between any 4 po es 'erra -s
h gh. Also, lhe 2.1:2light ratio
as described in "D" prov des
an deal geometry for efficient
parking lot iightlng

F r'e q-al ty of llu.r rat or


v r19r the EhG is easi'y
evaluated f rom the isolux line
pattern. The overall even
spacing between lrnes, w th no
t1 abrupt changes, indicates a
tota y smooth pattern on the
'iiir. ground. There are no hot spots,
il spl kes, or dead areas to destroy
uniror-ity and pole spac 1g
The EKG light pattern is totally
smooth and uniform in all areas.

Fixture ]1t ttl

--I
l'l
lJ The 2.1 .21ohI ratio from
\ ,:: o" to 45" to 50" is ideal
45" for parking lot ighting, and s

rl
)'\5 closely met by the EKG light
..\u''
::lr,::,,,,,,,,,,,:rlalrili'r"' \ pattern. This means that the 5
\\ 2 midpoints bretween any 4
equal y spaced poles, have
\1: almostthe same lightvalue. The
.\
,',i:lf \ 1 'esu't ,s greater pole spacings
as allowed by hlgher light levels
at the critical midpo nts
\\ ,l between poles. See plan v ew
5
\ illustration of a typical park ng
lot layout below.
'al,- I
.21
-:t '"llil\
.',:,ti.'' \
I'
aa'
l'.:t',.1

TD
.05 a ,..'
,irit

,:1r'

iii,r:iiatiaullllii irll:i:l.lllrliiiilli:l::iilllriiir:'ri

-.....1.".':.ri.rr:l:ii.rrrr"'--
':r'r,:.r'r::ir.rrr:arl,,rr:-_-

Plan View
Typical lsol rx Pattern ""':ji'ii'il
Maintained light
output through sealed
optics.

The optica chamber is the


heart of any high performance
luminaire. lt determlnes the
performance initially and over
years of operation. lf this
chamber gets dirty for any
reason, performance is $s }*st
ffi
decreased and energy wasted.
The EKG optical chamber is the
r;-- -, s$s{
sss
$fi$8

most metlculously sealed of any iri-


n the industry. Sealing from 'j --I
both the outside and inside
ensures maintained
performance year after year.
.,,'-WHil .!sii!$i!i:&*! .*.:t$sgi*;- };*liss{e
#l$*!;{#ffi '\-$IS$v
sryW
Wffi
;S**, -'
i$t€ilglis ;9tri6
E#SSq{l

Places where dirt, insects, and


polluted air try to enter the
ffiffiffiffiffiffiffi optical chamber.
Critical points where the optical
chamber must be sealed.

The most common place Contaminants can also Unless the fixture, arm, and
for contaminants to enter enter the optical chamber pole, are totally sealed at
the optical chamber is at the where the glass lens is held in every joint, contaminants can
reflector flange. To prevent its f rame. To prevent this, the also enter the optical chamber
this, the EKG reflector is EKG gasket completely from within. A one-piece
hydroformed in one piece with a surrounds the glass; interlocks reflector allows sealing f rom the
homogeneous flange. Against with the frame extrusion and inside because only the socket
this flange, a one-piece molded exerts constant pressure and wire penetrations need to
gasket exerts uniform pressure against the glass edge. A be gasketed. Segmented
around the perimeter. Of floating hinge permits the optical systems cannot be
particular importance are the 4 quarter-turn fasteners to sealed from the inside.
4 corners. where a one-piece provide equal pressure around
gasket is the only way to insure the gasket. No hinge or latch
a lasting seal. gimmicks are used because
they are unreliable and will
ultimately fail. The EKG latch
system is basic and reliable.

A1-4
Rapid installation,
easy maintenance,
and adaptability to
new technology.

Rapid installation and


easy maintenance.
Because the EKG is totally
modular, installation and
maintenance can be performed
quickly and easily With the
door frame and ba ast
assembly removed, the
housing s easily nstalled to tbe
po e and the wlre leads fed to
the po e top. The baliast
assemb y ls qu ckly mounted on
slip hrnges and connected to
the fle d wlres and socket leads
using quick-drsconnect plugs.
Th s procedure is simply
reversed for ba ast
rep acement a lowinq a
m n mum of expense for a rft
truck. The lens frame is
snapped nto the hous ng and
secured by the captive
quarter-turn atches No further
work is required on the f ixture
once the po e s raised

Adaptability to new
technology.
With energy a growing nationa
concern. there is no doubt that
major advances in lamp,
ba ast, and reflector
technology wiil take place
within the next decade. The
EKG is des gned to be
upgraded to these new
advances through simp e
rep acement of modular
components. There s no
reason for an EKG to ever
become obso ete or neff cient
It is tru y a ifetrme nvestrnent.

Photo at r ght shows


basic modu es of the EKG

w-ri
Materials and
construction
designed for
longevity.

I
I

The EKG housing is fabricated The EKG housing is comprised Every Klm f ixture is hand All fasteners, hinges, latches,
usrng a one-piece side wall of fully mitered heavy wall detailed to ensure proper f t and cl ps are made of the best
extrusion for superior strength sectrons that are internally and aesthetic quality, and al mater als and are plated, when
and a clean crrsp appearance. welded using high speed housings are satin polished as a necessary, to protect against
The extrusion contour includes metallic inert gas welders. base for either painted or rust. Each component is
integral ribs to inter ock with the Excellert weld penelration is anodized finlshes. assembled by personne
housing top and also assure a achieved creating a super trained not only in assembly
proper seal with the lens frame. strong housing, rmpervious to procedures, but quality control
Extrusions will not "oil can" like heavy wind loads. as well. Before packaging,
sheet metal housings and are every prece of hardware on the
ideal for accepting optional EKG is tested for proper
anodized finishes. alignment and function.

The EKG housrng s sealed on Kim pioneered the All electric components used in The overa I modular
the outside and inside with the one-piece hydroformed Kim EKG fixtures are UL listed. construction of the EKG is an
f inest silicone sealants reflectors for cut-off lighting in They are mounted, pre-wired to example of industrial design al
available. Tbe sealants are 1972. Afler years of field quick-disconnect plugs, and its finest. lt seems so simple
vlrtually unaffected by weather operation, these reflectors have tested at the Kim factory. These and right as to be effortless.
ra n, s eet, snow, remained virtually unchanged electrical su b-assemblies But behind its design lies a
-including
UV, ozone, and extreme by heat, UV, or periodic provide for rapid installation wealth of design and
temperatures. Aging tests in cleaning. Hydroforming and maintenance, and will engineering sophistication
Florida have shown almost no provides supenor strength, ulti.rately perm t the lu.ninaire found in no other fixture. lt is
change in physical properties dimensional stability, and to be easily upgraded for new truly the finest high
after 15 years exposure. creates a one-piece optical lamp technology. performance cut-of f luminaire
Weatherometer acceleration chamber capable of being obtainable.
tests lndicate a possible 150 tightly sealed All EKG
year life. reflectors are Alzak@ plated for
long term protection of the
mirror finish.
The Final Test

r$i
l$:
qit

Ask for a Sample! examlnation, we suggest the 6 ls the lens gasket 10. Are the components
Kim has been rnanufacturing following check list against one-piece? capable of being retrofitted
and shipping the EKG since competitive units: 7 Does the lens frame appiy for new technology without
1972. Since that time, there have 1. ls the housing made of a uniform gasket pressure excessive labor?
been many manufacturers who one-piece extrusion? around the reflector lip? 1 1 Are the fixture and mounting
have entered into making 2. ls the housing rigidly Are the electrical details clean?
versions of the Kim unit in welded and sealed with a components mounted and 12. Are the photomet'ics
various forms and materials. proven sealant? pre-wired as a provable from independent
The only way to determine 3. ls all the hardware plated to sub-assembly? testing laboratory reports?
whether yoJ are specifying or prevent rust? ls the door f rame and 13. Does the manuf acturer
purchasing the f inest luminaire 4. ls the reflector hydroformed electrical su b-assembly have financial responsibility
available is to make a table-top in one-piece? easily removable without the to back the product?
comparison. At Kim, we support 5. ls the entire optical use of tools, for installation 14. Do you get an overall
tris procedure and are anxious chamber sealed both f rom and maintenance? feeling of quality?
to furnish a sampie for l^;s the outside as well as the
purpose. ln making an inside?

4.1-7
Mounting Systems :
-

nl

I
tl
Standard fixture
arms for
mountings 1A,
28, 2L, 3r,

and 4C. Square or round poles


aluminum or steel.

Cluster mountrng bars


for mountings 2U, 4U,
3E and 6E.

Arm with splice


compartment for
mountings 1A and
2B only.

Laminated
wood poles

Arm with splice


compartment for Wall embedment
1W wall mount bracket for
only. concrete walls
only.

Square or round poles


wilh 21/2" pipe size tenons
in steel only.

Mounting Arrangements
in plan view
1A 28 2L 2U 3T .E 4C 4U 6E

H J u .L tt! + H #l I

A1-8
Mounting Details

I- .1A Standard mounting for aluminum

ttff-ib
or steel poles only.
H 28

J 2L

-L
+ 4C 6t, x21/2n
.1BB

Optional wood pole mounting


wall

I- 1A

28
-,---

6" x2Vz"
..188 wall

Optional wall mounting


for concrete walls only.

J-box in
wall, by others 6" x2lz"
.188 wall

u Optional cluster mounting for


steel poles with 2lz" pipe size tenons.

TTT
E
ll 4U

It
trr
fil "Field wire connections made here
Fixture Details

Optional Photocell Receptacle

T
I 10"
EKG4O1
70 watt to 250 watt

a--
n:'::-4:tqT:: \,.'-
Optional Lexan Shield
in place of glass.
250 watts max.

1 61r/r o"

Optional Photocell Receptacle

T
I 10,, EKG5O1
150 watt to 400 watt

Optional Lexan Shield


in place o[ giass. \
-
250 watts max. -\-
See note in Ordering lnformation.

Optional Photocell Receptacle

T
I 10" EKG601
1000 watt

41-10
Specifications, Specifications,
Standard Fixtures and Arms. Optional Equipment.

Fixture shall be Underwriter's Laboratories, lnc., listed. Houseside Shielding sha I

Housing shall be fabricated from a one-piece extruded aluminum consist of 2 shielding


side panel with mitered corners that are internally welded and components permanently
sealed for weather-tightness. A press-formed aluminum top cover rnsta led at the Kim factory.
shall interlock with the housing, and have a continuous seai of One component shall reduce
siltcone rubber resrstant to weathering, moisture, UV, and ozone. light direct y f rom the amp,
Top shall be peaked for rncreased strength and efficient and the other component
water runoff. shall reduce reflected light.
(For clear lamps only. See
Optical Chamber shall consist of a one-piece hydroformed Kim catalog A2 for photometrics)
reflector with a highly specular Alzak@ processed surface, and a
socket assembly. Socket shall be mounted in a one-piece casting Lexan@ Shield shall be one-
which is fully gasketed at the refiector surface Allwlres to the socket piece vacuum formed clear
shall be gasketed at point of entry into the optical chamber. polycarbonate to operate with
Reflector side walls and top shall be contoured so that no light is a maximum of 250 watts.
reflected back into the lamp arc tube, for optimum lamp life and (Shield may be used with
performance. For EKG 401 serres, ref lector shal hinge down for 400W HPS in locations where
ballast access using 2 quarter-turn latches, and snap out for outside air temperatures
installation ease. All MH lamps, all HPS lamps 200 watts and up, during fixture operation will not
and all MV lamps 400 watts and up sha I be supported at the tip by exceed 85'F.). Lexan Shield
a harness. All High Pressure Sodium fixtures shall be provided with shall be semi-pyramidal in
the appropriate 4KV or 5KV puise rated socket. shape for high thermal
Lens Frame Assembly shall constst of a 3/16" thick impact resistance, i mpact resistance
resistant clear tempered glass lens enclosed by a one-piece and light transmissjon. lt shall
molded high temperature gasket Lens and gasket shall interlock in replace standard glass lens as
an extruded aluminum frame whtch shall hinge at the pole end, and an integral part of the lens
f rame. Caution: Use only when
shall close and tightly seal the optical chamber by 4 gasketed
vrbratron-proof quarter-turn fasteners. Lens frame sha I be vandalism is anticipated to be
removable without tools by means of quick-disconnecting hinges. high. Useful life is limited by
discoloration caused by UV
All Electrical Components shall be UL approved and be an f rom sunlight, mercury vapor
rntegral part of the fixture Ballasts and related components shall be and metallic halide.
integrated onto a single mounting plate as a self-contained
subassembly On EKG 40.1 fixture, ballast assembly shall attach to Photocell Receptacle shall be integrally mounted to accept NEMA
the fixture us ng quick-dtsconnectrng key slots. On EKG 501 and base photocells (by others). When 2,3, or 4 f ixtures are mounted
EKG 601 ballast assembly shall attach to fixture wrth quick- per pole, one fixture shall be furnished with an installed receptacle
disconnect no-tool hinges and latches. Fast fleld winng shal be (plus a reiay when required)to operate the others. Photoce ls sha
provrded for by prewiring all electrica components with quick be furnished by others.
drsconnect p ugs. All ballasts shall be the component type capable Wood Pole Mounting sha I be by a modified arm containing an
of providlng lamp starting down to 20"F, with power factor of 90% access hole to allow field splices within the arm. A bearing plate
or better (High Power Factor) shall be furn shed between arm and wood pole, and al
Fixture Arm shall be a one piece rectangular aluminum extrus on components shall be f inished to match the f ixture Avallable for 1A
with rnternal centerng gu des. Luminaire-to-pole assembly shall be or 28 mountings only.
made through a mechanical draw bolt attachment inside the arm, Wall Mounting shall be by a modified arm containing an access
eliminating all exposed fasteners and weids Arm assembly shall hole to allow field splices within the arm. A wall embedment bracket
include a pole reinforcing plate which w ll mount tnside the pole for shall be provided to accept fixture mounting rods, and a trim plate
added strength at the arm joint. shall be provided to cover the wall embedded junction box. (J-box
Standard Finish on flxture and arm sha I be semi gloss black, by others). AII exposed parts shall be finished to match the fixtur
dark bronze, or natural aluminum baked enamel applied over a For concrete mounting only.
sat n po ish. Cluster Mounting types 2U, 4U, 3E and 6E, shall utrlize a
square mounting bar witb internal draw bo ts to mount the
fixtures. Mounting bar sha I attach to pole us ng a tenon wlth set
screws and one throughbolt. (Po e must have a 2lz" pipe size
tenon in steel only)
Anodized Finishes shall be Duranodic D b ack or dark bronze
applied over a satin polish according to Architectural Class 1
specif ications.
WARNING: This fixture must be grounded in accordance w th 'Lexan' s atrademark of Genera Electr c
oca codes, or the National E ectrlc code. Fai ure to do so may Duranodic satrademarkof Alcoa
result n serious personal injury.

41-1 1
Ordering
lnformation

1 Mounttns 2 r,*rur"" 4 ,,n,.n"" 6 ror""side Shietd

Plan View Cat. No Standard baked enamel For highly reduced light on
finishes houseside. Extra cost. See
I- 1A Cat. No. photometrics in catalog 42.
For clear lamps only.
BL-E Black baked enamel
H over satin polish.
DB-E Dark Bronze baked
Cat. No HS

J 2L
Standard
Cat No EKG401
for 70W. to 250W. lamps
lncludes complete fixture with
standard mounting arm, and
enamel over satin polish.
Resembles Duranodic@
313 in color.
NA-E Natural Aluminum baked

-L
mountings enamel over satin polish.
baked enamel finish. Less
ballast and lamp.

+
Optional Architectural Class I

anodized finishes at extra cost.


Cat. No.
BL-A Black anodize over
satin polish.
DB-A Dark Bronze anodize
over satin polish.
U Cat No EKG501
for 150W. to 400W. lamps.

UI Includes complete fixture with


standard mounting arm, and
baked enamel finish. Less
ballast and lamp.
IT
fi 4U
Optional
mountings
at extra cost
5 r"*"n Shield

ttt
ltt
Optional Lexan shield furnished
in place of glass lens, at extra
cost. 250 watts max.
Cat No LS
Cat. No. EKG601
Note: May be used with 400W

1
Wall
for 1000W. lamps.
Includes complete f ixture
with standard mounting arm,
and baked enamel finish. Less
HPS in locations where outside
air temperatures during fixture
operation will not exceed 85'F
mount ballast and lamp, Caution: Use only when
vandalism is anticipated to be
high. Useful life is limited by
discoloration caused by UV
from sunlight, mercury vapor,
and metallic halide lamps.
uata og l\um0er and
Ballast Cata

3
tJ Ballasts
Availabi ity Per Fixture Size.
NA - Not Available

Lne !ne Operat ng Siarting


Lamp (by others) Vo ts EKG4O]IEKGSO1IEKG6O1 Watts Amps Amps
124 70HPS1 20 BB 084 0.75
70W. High Pressure Sodium 2AB 70HPS208 BB 0.48 045
Clear, E-231/a. 5800 lumens 240 70HPS240 NA NA BB 4.42 037
277 70HP5277 BB 037 035
480 70HPS480 88 421 421
120 1 00HPS1 20 130 I I5 1.30
100W. High Pressure Sodium 208 1 00HPS208 i30 067 076
Clear, E-23t/2, 9500 umens 240 1 00HPS240 NA NA r30 058 0.66
277 100HPS277 t30 0.50 060
480 100HPS480 130 029 033
120 1 50HPS1 20 1 50HPS1 20 1BB 1.70 200
150W. High Pressure Sodium 208 1 50HPS208 1 50H PS208 lBB 100 1 15
C ear, E 2372, 16,000 lumens 240 1 50HPS240 1 50H PS240 NA lBB 085 100
55 Volt 277 1 50HPS277 150HPS277 1BB 075 0.85
484 150HPS480 1s0HPS480 1BB 04s 050
120 200HPS120 200HPS1 20 240 222 1.55
200W H gh Pressure Sodium 208 200HP5208 200HPS208 240 128 089
Clear, E 18, 22.000 lumens 240 200HP5240 200HPS240 NA 240 I tl 078
277 200HP5277 200HPs277 240 096 0.67
480 200HPS480 200HPS480 240 056 038
120 250HPS1 20 250HPSl 20 3r0 2.70 0.80
250W. High Pressure Sodium 208 250HPS208 250HPS208 310 1.55 045
Clear E-18, 30,000 lumens 240 250HPS240 250HPS240 NA 3i0 135 040
277 250HPS277 250HP5277 310 1 16 035
480 250HP5480 250HPS480 310 068 0.20
120 400HPS1 20 465 430
400W. High Pressure Sodium 208 400HPS208 465 2.48 'A'
156
C ear, E-18, 50,000 lumens 240 NA 400HPS240 NA 465 215 136
277 400HP5277 465 186 118
4BO 400HPS480 4b5 107 075
120 000HPS1 20 090 10 00 810
1000W. H gh Pressure Sodium 208 000HPS208 090 580 4.74
Clear. T-18, I40,000 lumens 240 NA NA 000HPs240 090 500 4ia
277 000HPs277 090 430 350
480 000HPs480 090 254 2AA
.175MH120
120 175MH120 2 0 rB0 090
I75W. Meta lic Hal de, Clear 208 175MH208 175MH208 2 0 1 .10 053
BT-28, 15,000 lumens Sockel 240 175MH240 175MH240 NA 2 0 092 046
provided for curved arc lamp. 277 175MH277 175MH277 2 0 080 040
480 175MH480 175MH480 2 0 047 4.23
120 250MH1 20 250MH120 294 260 140
250W Metallic Halide, Clear 208 250MH208 250MH208 294 i50 081
BT-28, 23,000 lumens. Socket 240 250MH240 250MH240 NA 294 130 071
provrded for curved arc iamp 277 250MH277 250MH277 294 112 060
480 250MH480 250MH480 294 065 0.35
120 400MH120 455 4.04 r50
4O0W Meta lic Hal de Clear 2AB 400MH208 455 23a a.B7
BT-37, 40,000 lumens Socket 240 NA 400MH240 NA 455 2AA 075
provided for curved arc lamp. 277 400MH277 455 1.75 065
4BO 400MH480 455 100 038
120 1 000MH1 20 1 070 920 400
1000W. lveta lic Ha de, C ear 208 1000MH208 I 070 530 24A
8T-56 107.800 umens 240 NA NA 1000MH240 I 070 460 200
277 1000MH277 1070 400 174
480 1000MH480 1A7O 230 100
120 175MV't 20 245 rB0 1.70
175W. Mercury Vapor, Delux 208 175MV208 205 100 0.98
Whlte, E 28, 8150 umens 240 175MV240 NA NA 205 090 0.85
277 17sMV277 205 076 074
480 175MV480 205 0.45 044
120 250MV1 20 250MV120 290 2.60 244
250W. Mercury Vapor, Deiux 208 250MV208 250MV208 290 r60 't.40
White, E-28, 1 1,500 lumens 240 250MV240 250MV240 NA 290 144 120
277 250MV277 250MV277 290 t t5 110
480 250MV480 250MV480 290 a7a 060
120 400MV1 20 454 390 3.24
400W. Mercury Vapor, Delux 208 400MV208 454 2.20 200
Wh te, E-37, 21 ,750 umens 244 NA 400MV240 NA 454 1.95 174
277 400Mv277 454 170 150
4BA 400MV480 454 098 095
120 1 000MV1 20 075 950 430
1000W. Mercury Vapor, Delux zu6 1000MV208 475 5.50 250
White, 8T-56, 60,000 lumens 240 NA NA 1000MV240 475 4. B0 224
277 1000MV277 075 4.30 190
480 1000MV480 075 250 r30
Ballast Catalog number inc udes ba last,
capacitor starter if requrred, al mounted and
See Cataioo A2 tor detaired ramp oal ore-wired to the mountino Dlate.
Photocell
Receptacles Photoce 1s by others 8 ,o,""
Amps
rlr ng Wattage Cat No Volts Relay Al poles for EKG ser es f xtures
are catalogued on indivrdual
075 l- 7OW to ]0OOW A-25 120 No
specif icatron sheets co or
015
037
035
a.21
I One f rxture,
pole or wal
rnounted.
208
240
277
coded n orange.
See Kim
480
Po e Type Spec. Sheet
130
0.76 H 70W to40OW A-25 124
Square
Tapered PTSSK or
No Stee
Ju
PGK
066 Two fixtures 208
060 Non-Tapered -PSA
per pole. 240
033 Square Alumrnum
277
2.40 Non Tapered PSSK or
i 15
480
Square Steel PFK
r00
085
050
155 .L 70W. to 4O0W
Three fixtures
A-25 120
208
No Non-Tapered
Round Aluminum
Tapered Round
PNTRA

PTBS or

ru
per pole. 240
089
277 Steel PHV
078
067 480 Tapered Bound PTRA or

+
038 A uminum XTRA
70W. to 250W 120
080 Four Fixtures 208 Laminated Wood PSWB and
045 PXWB
per pole. 240
040
035 277
020 III 480
,
i156
2.82 rlr
r36 H 000w A-25-l 120

Ju
1
r re
i1075 Two fixtures A-25-2 208
per pole. A-25-3 240
i-Bro A-25-4 277
I qto A-25-5 480
I a ro
I350
lzoo
090
053
0
040
,16
-L
ru
1000w.
Three fixtures
per pole.
A-25-1
A-25-2
A-25-3
A-25-4
A-25-5
120
208
240
277
480
Yes

'Non-tapered square aluminum


^n2 po es are available with the

+
exclusive Kin H nged Base ir
ir10 400W to 1000W A-25-1 120 heiqhts up to 14 feet. U S Patent
I 0 Bl Four frxtures A-25-2 208 4,079,559.
1 0 71 per pole. A-25-3 240
I060
lo3s A-25-4 277
lt! A-25-5 480
loez
i075
150
rll
065
038
4 rro
240
2a0
174
100 Ordering Guide
trO
098
08s
474
4.44
1 4 56 7
2AA
't.44
124
t t0
060
*
c.al
200
r70
irso
logs
430
250
2.20
190
130

2 B/E KG501 /250 Hp 5277 / BL-A/LS/H S/A-2slp SA-25 B/B L-A

41-13 41-14

Вам также может понравиться