Вы находитесь на странице: 1из 16

R

SUYANG

Automatic Transfer Switches

Innovation
YANGZHOU SUYANG ELECTRIC CO.,LTD.
Address: Yongxun Road 1, Dayi Industrial Zone,
Dayi Town, Yangzhou, Jiangsu, China.
Sales hotline: +86 (0)514-82888885
Excellence
Service hotline: +86 400-888-5848
Web site: http://www.yzsuyang.cn Integrity

R YANGZHOU SUYANG ELECTRIC CO.,LTD.


SUYANG
YANGZHOU SUYANG ELECTRIC CO.,LTD. YANGZHOU SUYANG ELECTRIC CO.,LTD.

ABOUT US >>>
90 0 1
We provided power protection

01 ISO
system to three stadiums of

9 0
ISO
Nanjing YOG

90 0 1
IS O IS O 9 0 0 1

9 0 0
ISO
YANGZHOU SUYANG ELECTRIC CO.,LTD. YANGZHOU SUYANG ELECTRIC CO.,LTD.

CERTIFICATE >>>
YANGZHOU SUYANG ELECTRIC CO.,LTD. YANGZHOU SUYANG ELECTRIC CO.,LTD.

CERTIFICATE >>>
YANGZHOU SUYANG ELECTRIC CO.,LTD. YANGZHOU SUYANG ELECTRIC CO.,LTD.

Content

About us

Certificate

Product Introduction 01-05

SYK2 Series Automatic Transfer Switch 20-100A 06

>>>
SYK1 Series Automatic Transfer Switch 20-160A 07

SYK1 Series Automatic Transfer Switch 200-300A 08

SYK1 Series Automatic Transfer Switch 400-630A 09

SYK1 Series Automatic Transfer Switch 800-1000A 10

SYK1 Series Automatic Transfer Switch 1250A 11

SYK1 Series Automatic Transfer Switch 1600A 12

SYK1 Series Automatic Transfer Switch 2000-3200A 13

SYK Series Connection Mode 14-16

SYKZ-F Type Controller 17-18

SYKZ-B Type Controller 19-20


YANGZHOU SUYANG ELECTRIC CO.,LTD. YANGZHOU SUYANG ELECTRIC CO.,LTD.

To Meet The Needs Of Different Places Features

SYK series dual power automatic transfer switch is suitable for power system of insulation volt 750V,
rated frequency 50HZ/60HZ, rated working volt 440V and below, rated current 20A~3200A.
SYK series ATS let the power supply system transfer between two power in emergency, the minimum
conversion time is 0.3s to make sure the main load (emergency lighting, emergency staircase, fire-fighting
system, etc) working continuously and reliably.

Widely used in high-rise buildings, telecom-


munications, industrial and mining, shipping,
power stations, hospitals, banks and other
places need uninterrupted power supply.. Products can select different operate modes
Products with higher short-term tolerance, Products with manual, automatic and other modes, of automatic change and automatic recovery,
ensuring continuity of supply. can adapt to the needs of different places. automatic change without automatic recovery,
mutual back up. It makes the product to be
used more widely.

Note: The conversion time of transferring


between two power in emergency≤0.3s.
Small size, light weight, small installation Two into one and two into two makes the Configure a variety of control modes to meet
space can reduce the cost of complete product to be used more widely. different needs.
sets effectively.

01 02
YANGZHOU SUYANG ELECTRIC CO.,LTD. YANGZHOU SUYANG ELECTRIC CO.,LTD.

Combined Multi-technology Instruments Multi Series For Selection

01
06 Controller
1.The static contact
2.The movable contact
3.The combination of dynamic SYK2/SYK1
and static sliding mechanism
Automatic Transfer Switch
02 4.The switch-storage mechanism
5. The whole mechanism of #I/#II 扬州市溯扬电气 有限公司
SYK2-20-100A SYK1-20-160A
6. Dual power switch
SYKZ-F

03 04 05

SYK1-200-300A SYK1-400-630A SYK1-800-1000A

SYKZ-B
The body uses double row composite contact, separated static and movable contact and horizontal pull-out mechanism.
Basically achieve zero arcing (no arc chute).
The rod mechanism use spring energy storage, instantaneous release, open and close fast to reduce arcing effectively
when opening.
The closing mechanism equips with a mechanical interlock and electrical interlock to prevent simultaneous closure of
the two-way power.
Surface of wiring cooper using 99.9% pure silver plating process, coating 12 microns thick to reduce rising copper tem-
perature. SYK1-1250A SYK1-1600A SYK1-2000-3200A

03 04
YANGZHOU SUYANG ELECTRIC CO.,LTD. YANGZHOU SUYANG ELECTRIC CO.,LTD.

Model and Meaning SYK2 SERIES Automatic Transfer Switch 20-100A

SY K / ◆Main Technical Parameters

Conventional heating current 20A 40A 63A 80A 100A

Rated insulation voltage 750V


Quantity of poles
Rated impulse withstand voltage 8KV
A (auto), S (remote control) Rated voltage 440V
E (generator), L (double load type) Rated working current 20A 40A 63A 80A 100A
Rated current Nature of the load AC-33IB

Rated making ability 10Ie


Serial number
Rated breaking capacity 8Ie
Automatic transfer switch Rated conditional short-circuit current 100KA

Rated short-time withstand current 7KA


Yangzhou Suyang Electric Co.,Ltd
Transfer time ≤3S
SYK2-20-100A
Input voltage AC220V

Menu
◆Installation Dimension
Model Main Function Remark
245
SYK
Fully automatic
( basi c ty pe ) 2 33 36

SYK
Automatic/manual/remote control, forced to set”0”, interlock
(fire fighting type)

SYK Automatic/manual/remote control, forced to set”0”, interlock,


(intelligent type voltage/frequency transfer delay adjustment, fault alarm and The controller B
+controller B) status indication

Automatic/manual/remote control, forced to set”0”, interlock,


SYK voltage/frequency transfer delay adjustment, the oil machine
(oil machine type+ The controller F
controller F) start (signal), fault alarm

SYSD
Manual Switch
(manual)

U n i t:m m

05 06
YANGZHOU SUYANG ELECTRIC CO.,LTD. YANGZHOU SUYANG ELECTRIC CO.,LTD.

SYK1 SERIES Automatic Transfer Switch20-160A SYK1 SERIES Automatic Transfer Switch200-300A

◆Main Technical Parameters ◆Main Technical Parameters

Conventional heating current 20A 40A 63A 80A 100A 125A 160A Conventional heating current 200A 250A 300A
Rated insulation voltage 750V Rated insulation voltage 750V
Rated impulse withstand voltage 8KV Rated impulse withstand voltage 8KV
Rated voltage 440V Rated voltage 440V
Rated working current 20A 40A 63A 80A 100A 125A 160A Rated working current 200A 250A 300A
Nature of the load AC-33IB Nature of the load AC-33IB
Rated making ability 10Ie Rated making ability 10Ie
Rated breaking capacity 8Ie Rated breaking capacity 8Ie
Rated conditional short-circuit current 100KA Rated conditional short-circuit current 100KA
Rated short-time withstand current 7KA Rated short-time withstand current 9KA
Transfer time ≤3S Transfer time ≤0.4S
SYK1-20-160A SYK1-200-300A
Input voltage AC220V Input voltage AC220V

◆Installation Dimension ◆Installation Dimension

59
345 58

9 50 11

160
80

43

190
33

Unit:mm Unit:mm

07 08
YANGZHOU SUYANG ELECTRIC CO.,LTD. YANGZHOU SUYANG ELECTRIC CO.,LTD.

SYK1 SERIES Automatic Transfer Switch400-630A SYK1 SERIES Automatic Transfer Switch800-1000A

◆Main Technical Parameters ◆Main Technical Parameters

Conventional heating current 400A 630A Conventional heating current 800A 1000A
Rated insulation voltage 750V Rated insulation voltage 750V
Rated impulse withstand voltage 12KV Rated impulse withstand voltage 12KV
Rated voltage 440V Rated voltage 440V
Rated working current 400A 630A Rated working current 800A 1000A
Nature of the load AC-33IB Nature of the load AC-33IB
Rated making ability 10Ie Rated making ability 10Ie
Rated breaking capacity 8Ie Rated breaking capacity 8Ie
Rated conditional short-circuit current 70KA Rated conditional short-circuit current 100KA
Rated short-time withstand current 13KA 50KA
Rated short-time withstand current
Transfer time ≤0.6S Transfer time ≤1.2S
SYK1-400-630A SYK1-800-1000A
Input voltage AC220V Input voltage AC220V

◆Installation Dimension ◆Installation Dimension

610
83

13
100

9
260
Unit:mm

Unit:mm

09 10
YANGZHOU SUYANG ELECTRIC CO.,LTD. YANGZHOU SUYANG ELECTRIC CO.,LTD.

SYK1 SERIES Automatic Transfer Switch1250A SYK1 SERIES Automatic Transfer Switch1600A

◆Main Technical Parameters ◆Main Technical Parameters

Conventional heating current 1250A


Conventional heating current 1600A
Rated insulation voltage 750V
Rated insulation voltage 750V
Rated impulse withstand voltage 12KV
Rated impulse withstand voltage 12KV
Rated voltage 440V
Rated voltage 440V
Rated working current 1250A
Rated working current 1600A
Nature of the load AC-33IB
Nature of the load AC-33IB
Rated making ability 10Ie
Rated making ability 10Ie
Rated breaking capacity 8Ie
Rated breaking capacity 8Ie
Rated conditional short-circuit current 100KA
Rated conditional short-circuit current 120KA
Rated short-time withstand current 50KA
Rated short-time withstand current 50KA
Transfer time ≤1.3S
SYK1-1600A Transfer time ≤1.3S
SYK1-1250A AC220V
Input voltage
Input voltage AC220V

◆Installation Dimension ◆Installation Dimension

100
98
13
9

9
U n i t:m m Unit:mm

11 12
YANGZHOU SUYANG ELECTRIC CO.,LTD. YANGZHOU SUYANG ELECTRIC CO.,LTD.

SYK1 SERIES Automatic Transfer Switch2000-3200A Typical Connection Mode


◆Main Technical Parameters Note: users can choose one of the following connection modes. As to automatic switch, just connect copper wiring,
a second connection is not necessary. 302-305 is switch status indicator.
Conventional heating current 2000A 2500A 3200A Terminal method: only one set of six terminals.
Rated insulation voltage 750V
Rated impulse withstand voltage 12KV

Rated voltage 440V

2000A 2500A 3200A


Rated working current
301 302 303 304 305 306 1. automatic wiring (basic)
Nature of the load AC-33IB Ⅰ commonly used power indicator
Rated making ability 10Ie Ⅱ standby power indicator
Rated breaking capacity 8Ie Ⅰ Ⅱ

Rated conditional short-circuit current 80KA

Rated short-time withstand current 55KA

Transfer time ≤2.4S


220V input load side switch status indicator
SYK1-2000-3200A Input voltage AC220V

◆Installation Dimension
Prime power Standby Power
AC220V AC220V 2.Automatic Wiring
mechanical
Auto /manual interlock
FU1 FU2 Mode indicator indicator
80 HL1 HL2
(Passive) (Passive)
201 202 203 204 205 206

Automatic Wiring
9

101 102 103 104 105 106 501 502 503 504 505 506
Hl1 is the indicator for the using of prime power.
HL2 is the indicator for the using of standby power,
350

SYK
HD1 is the indicator to connect the prime power,
301 302 303 304 305 306 401 402 403 404 405 406 HD2 is the indicator to connect standby power input
FU1 / FU2 is 2A fuse
HD1 HD2
101 to 106,201-206,301-306 for SYK switch terminals
External connection 401-406,501-506 are switch terminals optional for ATS
indicator

AC220V Input
(Passive)
above 630A.

610 Unit:mm

13 14
YANGZHOU SUYANG ELECTRIC CO.,LTD. YANGZHOU SUYANG ELECTRIC CO.,LTD.

3. SYK automatic + forced zero protection (fire fighting, 5.Automatic + Manual (remote control) Wiring
dual power supply are disconnected) Prime power Standby Power
Prime power Standby Power AC220V AC220V
AC220V AC220V

mechanical
mechanical
Auto /manual interlock Automatic 1 3
Auto /manual FU1 FU2 Mode indicator
Manual SA
interlock indicator
FU1 FU2 Mode indicator indicator HL1 (Passive) (Passive)
HL2 2 4
HL1 (Passive)
HL2 (Passive) (Remote)
201 202 203 204 205 206 SB2
SB1

101 102 103 104 105 106 501 502 503 504 505 506 101 102 103 104 105 106 501 502 503 504 505 506
Forced zero contact (passive input)
201 202 203 204 205 206
SYK Hl1 is the indicator for the using of prime power.
SYK
HL2 is the indicator for the using of standby power,
301 302 303 304 305 306 401 402 403 404 405 406 HD1 is the indicator to connect the prime power, 301 302 303 304 305 306 401 402 403 404 405 406 SA is the switch choose automatic or manual mode.
HD2 is the indicator to connect standby power input SB1 is the manually input button for prime power.
HD1 HD2

External connection
FU1 / FU2 is 2A fuse HD1 HD2 (passive contact).
indicator
(Passive) 101 to 106, 201-206, 301-306 are SYK switch terminals External connection
SB2 is the manually input button for standby power
AC220V Input indicator
(Passive)

401-406, 501-506 are switch terminals, optional for ATS AC220V Input (passive contact).
above 630A.

Prime power Standby Power


AC220V AC220V
6.Remote Control (manual only) Wiring
For ATS already have a generator interface (301-306 4. Connection mode of start a generator signal.
have words UGE1), wiring diagram as follows: Auto /manual
mechanical
interlock
FU1 FU2 Mode indicator indicator
HL1 HL2 (Passive) (Passive)
SB1 SB0 SB2

UGE1 is passive contact, connect generator


interface.
101 102 103 104 105 106 501 502 503 504 505 506

301 306 201 202 203 204 205 206


SYK

301 302 303 304 305 306 401 402 403 404 405 406 SB1 is the control button for input of prime power (passive contact).
301 302 303 304 305 306
SB0 is the control button for input of forced to zero power (passive contact).
HD1 HD2

External connection
SB2 is the control button for input of standby power (passive contact).
indicator
(Passive)
AC220V Input
UGE1 Note: UGE1 is AC220V relay inside the switch. 301-306
are interfaces to start the generator.

15 16
YANGZHOU SUYANG ELECTRIC CO.,LTD. YANGZHOU SUYANG ELECTRIC CO.,LTD.

SYKZ-F Controller
Technical Parameters Mounting Dimensions
Operator Panel
Power Input Normal power delay: (0-60) seconds(can be set by controller panel potentiometer).
110mm
Controller AC power supply: AC230V±20%(50/60Hz)( A,N- phase Abnormal power delay: (0-60) seconds, factory value: 5s (can be set by controller
Manual Status Indication
voltage of line Ι,ΙΙ) panel potentiometer).
Detection voltage: rated 380V (50/60Hz) three-phase four-wire,
Start delay of genset: after lineΙ abnormality confirmation, delay start (0s-60s , only
others please confirm with the manufacturer. Ⅰ AUTO

be set via panel potentiometer). # I Power Indicator # II Power Indicator

60mm
Setting Parameters Stop delay of genset: after lineΙ normality confirmation, delay start (0s-60s , can be # I Closing Indicator # II Closing Indicator
30 30

Overvoltage threshold: 264V(only be set by the PC). set via panel potentiometer or PC). # I Power Normal Delay
20

10
40

50
AUTO
20

10
40

50
# II Power Normal Delay
Potentiometer 0 60 0 60 Potentiometer
Under voltage threshold: 172V(only be set by the PC). Line Ι/ΙΙ closed state test (available to be programmed through the control panel 0 0 : 00 00:00

buttons) factory settings: detection Line Ι/ΙΙ closed state inputs, in other words the # I Power Manual Closing
Button
I o Ⅱ # II Power Manual Closing
Button

6mm
controller must be connected to a closed state signal.
Action Time Yangzhou SuYang electric co., LTD
Power consumption: power consumption of the voltage loop (under rated voltage)
Closing time: 5s, if detecting closing signal during this period, disconnect Automatic/Manual Switching Button
≤2VA. Automatic Status Indicator
at once. Double points button

Opening time: 3s, if detecting closing signal during this period, disconnect Ambient condition: temperature: (-30~+70) ℃;humidity:(20~95)%。
Net Weight: 0.47kg.

119mm
at once.

The programmable parameters and range Typical Connection Mode Of ATS Cooperated With Controller-VE ATS
load
No. Items Range Default Remark 129mm
L1 L2 L3 N

138mm # I Power Input # II Power Input


1 normal delay of #I volt (0-60)S set by panel potentiometer only set by panel potentiometer
R1

2 normal delay of #II Volt (0-60)S set by panel potentiometer only set by panel potentiometer S1
T1

3 Start delay of genset set by panel potentiometer set by panel potentiometer or PC Hole Size N1
(0-60)S
103 102 202 204 203 205 302 303 305
4 abnormal delay of #I volt (0-60)S 5S set by panel potentiometer or PC

10A
10A
10A
10A
10A

10A
5 abnormal delay of # II volt (0-60)S 5S set by panel potentiometer or PC
N1 C1 B1 A1 N O LO COM 0 I II GND S1 S 2 A2 B2 C2 N2
130mm

Control the public side


6 stop delay of genset (0-60)S set by panel potentiometer or PC ATS Power

By the controller

# I Closing State

# II Closing State
60S

# II Closing Control
# I Closing Control
Opening Control
Supply

111mm
7 Volt Upper Limit (50-300)V 264V only programmed through PC

8 Volt Lower Limit (60-300)V 172V only programmed through PC


ATS Controller
9 Power Priority #I power priority, #II power priority, no priority power #I power priority set by panel potentiometer or PC

10 detection of closed state input detect only set by panel potentiometer

17 18
YANGZHOU SUYANG ELECTRIC CO.,LTD. YANGZHOU SUYANG ELECTRIC CO.,LTD.

SYKZ-B Controller
Installation And Use
SYKZ ATS controller is an intelligent dual-supply switching module with automated measurement. It combines with digital, intelligent

and network. Automated measurement and automated control process make it reduce operational errors. The controller should be installed on its working position and connected according to the following diagram. An 0.035Ω

ATS controller is an automatic control module using microprocessor as core. It can accurately detect 2-way 3-phase voltage and judge
constant value wire is required when connect to ATS. The wire between controller and ATS will be not too long to
prevent installation problem of instability voltage. Because too long wire will cause power lose.
voltage abnormal (such as, over voltage, under voltage and lack of phase), then control ATS will output passive to control the switch. SYKZ-B

controller fully consider the application in various ATS (automatic transfer loading system), can be directly used for ATS, contactor ATS, air
SYKZ controller and SYK ATS connection diagram
switch ATS, etc. Its compact structure, advanced circuits, simple wiring, high reliability, make it widely used in industry of electric power,

telecommunications, oil and coal, metallurgy, railway, municipal, intelligent building to setup electrical, automatic control and debug system. Standby power Main Power

N2 W V U N1 C B A
130mm
Fu6 Fu5 Fu4 Fu3 Fu2 Fu1
110mm

F4 F3 F F1 F2 N1 M1 M2 N2 RN C2 B2 A2 NN C1 B1 A1 Controller Terminals

101 102 103 104 105 106 201 202 203 204 205 206 ATS Terminals
Total Depth: 73mm, Cabinet Inner Depth: 61mm

Hole Size
Note:

1.When commonly used power off, F and F1, F3 on, F and F2, F4 off.

2. When commonly used power on, F and F2, F4 on, F and F1, F3 off.

3.When main power closing, N1 and M1 output 220V power, the output connect to terminals 102,103 of ATS main power.

4.When standby power closing, M2 and N2 output 220V power, the output connect to terminals 104,105 of ATS standby power.

19 20
G i ve d r e am a
s oar i n g w in g s

YANGZHOU SUYANG ELECTRIC CO.,LTD. YANGZHOU SUYANG ELECTRIC CO.,LTD.

CORPORATE PHILOSOPHY >>>

Our Service
Customer Focused, Deep Expertise, Valued Products & Service Sales hotline: +86 (0)514 82888885
Service hotline: +86 400 888 5848
Our Vision
Best Solution, Superior Results, Search For Efficiency

Our Value
Best Team, Continuous Improvement Culture, Environmental And
Order Notice:
Community Responsibility Please kindly provide item no., rated current, rated voltage, primary system diagram, the selected sub-line
component name of inlet and outlet, technical specifications when ordering. Any other requirements, please
contact with us in the first time.

Вам также может понравиться