ATTENTION
The 14-slot packet-optical shelf assemblies only operate with Release 9.0 or
higher software loads.
Table 3-3
6500 14-slot common equipment in 14-slot packet-optical shelf versus other 14-slot shelf types
Maintenance NTK505FAE5 ¥
Interface Cards (see Note 2)
(MIC)
Maintenance NTK505FBE5 ¥ ¥ ¥
Interface Cards
(MIC)
BIP/FIP NTK599AAE5 ¥ ¥
NTK599BGE5
NTK599DAE5
NTK599EAE5
NTN458RAE5
BIP NTK599BAE5 ¥ ¥ ¥
Rectifier NTN458SAE5 ¥ ¥ ¥
Cross-connect NTK557AAE5 ¥ ¥
circuit packs NTK557BAE5
NTK557NAE5
NTK557PAE5
NTK557QAE5
NTK557TBE5
NTK557EAE5
NTK557GAE5
Cross-connect NTK615AA ¥
circuit packs NTK615BA
NTK557ES
NTK557GS
Note 1: Some 14-slot shelf types are equipped with a cooling shelf that is not compatible with some
cooling fan modules. For cooling fan/shelf compatibility, see Planning - Ordering Information, 323-1851-
151.
Note 2: With 14-slot NTK503xA/NTK503xB variants, this fan can be equipped in a front-venting cooling
shelf (NTK507FA, NTK507FB), but is not supported in a top-venting cooling shelf (NTK507EA,
NTK507EB) or a rear-venting cooling shelf (NTK507GA, NTK507GB).
Note 3: With 14-slot NTK503xA/NTK503xB variants, this fan can be equipped in a rear-venting cooling
shelf (NTK507GA, NTK507GB) but is not supported in a top-venting cooling shelves (NTK507EA,
NTK507EB) or a front-venting cooling shelf (NTK507FA, NTK507FB).
Note 4: High flow cooling fan modules (NTK507LDE5, NTK507MDE5 or Type 3 variants NTK507LS,
NTK507MS) are required when high performance circuit packs such as SuperMux, 20G L2SS, 100G
OCLD, 100G WL3/WL3e OCLD, Flex2 WL3/WL3e OCLD, Flex3 WL3e OCLD, 100GE OCI, 100G OCI,
10x10G MUX, 10x10GE MUX, 100G (2xQSFP+/2xSFP+) MUX, 40G UOCLD, 40G OCLD, Wavelength-
Selective 40G OCLD, 40G XCIF, 16xFLEX OTN I/F, 40G OCI, 40/43G OCI, 40G+ CFP OCI, 100G
WL3n MOTR, 100G WL3e OTR, or 40G MUX OCI circuit packs are equipped in a 14-slot shelf.
Note 5: Using high flow front cooling fan module (Type 3) (NTK507LS) or high flow rear cooling fan
module (Type 3) (NTK507MS) in a 14-slot packet-optical shelf (NTK503SA) requires that the shelf is
also equipped with 2x50A Power Input Card (NTK505DS).
Note 6: Only supported on converged optical (NTK503ADE5) and converged optical/rear electrical
(NTK503CDE5) shelf types.
Note 7: Only supported on converged optical/front electrical (NTK503BDE5) shelf type.
For more information about the E1, DS3/E3/EC-1, STM-1e, and 10/100BT
hardware, see Electrical Circuit Packs, 323-1851-102.2.
Figure 3-7
Optical/front electrical shelf and converged optical/front electrical shelf —electrical interface area
When installed, this hardware allows for up to 504 75 ohm or 120 ohm E1
electrical interfaces. Cabling associated with interfaces can be routed via
either side of the shelf.
Figure 3-8 shows the layout of the electrical interface area fitted with the DS3/
E3/EC-1 interface hardware. For more information about the DS3/E3/EC-1
and 10/100BT hardware, see Electrical Circuit Packs, 323-1851-102.2.
Figure 3-8
Optical/rear electrical shelf and converged optical/rear electrical shelf—electrical interface area
E1 electrical hardware
The E1 electrical interface hardware includes up to eight I/O modules. When
installed, this hardware allows for up to 504 75 ohm or 120 ohm E1 electrical
interfaces. Cabling associated with interfaces can be routed via either side of
the shelf and can also be routed to the rear of the shelf.
Figure 3-9 shows an example of the layout of the electrical interface area fitted
with the E1 interface hardware. For more information about the E1 hardware,
see Electrical Circuit Packs, 323-1851-102.2.
Figure 3-9
Metro front electrical shelf—electrical interface area