SISGEO is a leading designer and manufacturer of a wide selection of instruments
for use in the area of rock and soil measurement and analysis.
SISGEO instruments are supplied worldwide through a growing distribution network.
In the past several years, sales have been equally distributed between domestic and
international markets.
SISGEO was established in 1993 when the current shareholders acquired
SIS Geotecnica. Ever since, SISGEO has been dedicated to the development,
manufacturing and supply of high quality instruments in order to meet the demands
of civil engineering projects.
The link to SIS Geotecnica, founded in 1973, is very important as it is a major factor
in the success of SISGEO. We have the dynamic attitude of a young organization, as
well as the tradition and experience of a long established company.
Located in the industrial belt of Milan, SISGEO headquarters consists of a three-story
building with more than 1.200 square meters of laboratories, production facilities,
and a warehouse. The location also includes 600 square meters of offices for the
technical and R&D departments, as well as marketing and sales.
The headquarter of SISGEO also includes more than 1.200 square meters of open
area, parking facilities and an additional building of 160 square meters hosting a
workshop and production line for fiberglass rod extensometers.

Our vision and strategy


Our vision is to be dedicated in serving our Customers and respecting the
environment where we live, “The earth speaks to us... we listen to it”. We believe in
progress, growth and opportunity.
Our business strategy relies upon long-term cooperative relationship with our
Customers, Partners and Distributors.
We are passionate about our Customers and are working to meet the needs they
have today and constantly innovating our solutions to meet the needs of tomorrow.
With their support, we can maximize the potential of our traditional business, through
a combination of enhanced quality of service, creative marketing, innovative pricing
and costs efficiency.

company profile 5 www.sisgeo.com


GROUP
THE

a qualified staff offering


customized solutions.
The Group
Located in the Greater Milan area (Italy), the company has been active in the field
of geotechnical and structural monitoring since 1973.
SISGEO is now the leading entity of a Group that includes SISGEO HOLDING,
FIELD and SISGEO-ZEMIN.
SISGEO’s core business consists in the manufacturing of a complete range of
instrumentation for Structural, Hydrological, Geotechnical (rock and soil),
Environmental monitoring purposes, and the associated design of specific project
solutions. SISGEO is one of the top three manufacturers in the world for revenues,
profitability and market’s geographic reach.
SISGEO HOLDING is the Swiss-based company intended for investments in
services companies throughout the world and for particular trading/marketing
operations.
FIELD is a service company which was established in 2000 in order to better
service our customer requirements by offering expertise on monitoring design,
on-site technical assistance, installation supervision, in-situ testing, training,
measurements and data processing.
SISGEO-ZEMIN was recently founded in Turkey, to carry on the monitoring
activities on projects where Sisgeo’s instruments have already been installed, and
to offer assistance and customized services to the local market. Sisgeo Holding
is Sisgeo-Zemin’s main shareholder.

Quality System
The core value of SISGEO is to provide our Customers with top quality products and
exceptional services, that meet or outperform the highest quality standards.
In 1997 (and following updates), SISGEO achieved ISO 9001 Certification, which is
the starting point of our continuous improvements and quality control programs.
Nowadays SISGEO is registered according to ISO 9001:2008 standard.
The SISGEO Quality System ensures full traceability of all our products.

company profile 7 www.sisgeo.com


T EC H N O LO GY
an advanced technology
combined with our passion.
Technology
SISGEO has made considerable investments to develop technologies and advanced
tools to be used in production.
Continuous research allow us to find excellent solutions in order to reduce
manufacturing costs and provide a competitive and complete line of products,
ensuring thus the growth of our volume of sales.
SISGEO produces both vibrating wire, the best for geotechnical applications, and
resistive strain-gauge technologies. SISGEO ranks among the few world
manufacturers which produces international quality vibrating wire instruments.

Manufacturing Facilities
The SISGEO production department has exemplary tools and equipment for
assembling, building and calibrating instruments of the highest quality and reliability.
These include:
- four vibrating wire sensor assembly desks;
- a TIG welding;
- calibration desks for inclinometers;
- a unique under-vacuum system for saturating hydraulic cells;
- three climate chambers for environment temperature tests;
- semi-automatic tool for fibre glass rod extensometer assembling;
- load testing machine up to 3000 KN;
- two pressure vessels for leakage and waterproof tests;
- bi-components epoxy resin dispenser for sealing products.

A significant contribution to the growth of the company has been provided by our
team of hardware and software specialists, as all new machines and testing systems
are electronically controlled for the automatic generation of calibration certificates.

company profile 9 www.sisgeo.com


PRESSURE TRANSDUCERS
casagrande and standpipe piezometers 12-13
water level indicators (WLI) 12-13
water level logger (WLL) 12-13
electrical pressure transducers 14-15
flow meters 14-15
vibrating wire piezometers 14-15

INCLINOMETERS
standard inclinometer casings 16-17
flush coupled and quick joint inclinometer casings 16-17
inclino-settlement columns 16-17
inclinometer probes 18-19
archimede datalogger 18-19
TILLI portable tiltmeter 18-19
INDEX

in-place inclinometers (IPI) 20-21


RDS system (Railway Deformation System) 20-21
surface clinometers and beam clinometers 20-21

SETTLEMENT GAUGES
magnet extensometer (BRS) 22-23
T-REX removable extensometer 22-23
DEX in-place extensometers 22-23
DSM building monitoring system 24-25
hydrostatic profile gauge (PROFILER) 24-25
DSM embankment monitoring system 24-25

PRESSURE & LOAD CELLS


earth pressure cells 26-27
NATM stress cells 26-27
hydraulic pressure cells 26-27
hydraulic anchor load cells 28-29
electrical anchor load cells 28-29
steel lining and solid load cells 28-29
EXTENSOMETERS & JOINTMETERS
digital tape extensometer 30-31
mechanical jointmeters 30-31
DBS measuring anchors 30-31
borehole rod extensometers 32-33
DTE displacement transducers 32-33
embankment extensometers 32-33
crackmeters & jointmeters 34-35
wire crackmeters and deformeters 34-35
fixed extensometers 34-35

PENDULUMS & READOUT


direct & inverted pendulums 36-37
removable coordinometer 36-37
TEL-310S telecoordinometer 36-37

STRAIN GAUGES & THERMOMETERS


arc-weldable and embedment strain gauges 38-39
spot weldable strain gauges 38-39
vibrating wire rebars and shotcrete strain gauges 38-39
resistive strain gauges 40-41
embedment thermometers 40-41
portable thermal probes 40-41

READOUTS, DATALOGGERS & ACCESSORIES


readout units 42-43
portable dataloggers 42-43
field miniloggers 42-43
ADK-100 data acquisition system 44-45
ADK-100 components 44-45
software and web services 44-45
junction and terminal boxes 46-47
readout accessories and spare parts 46-47
cables 46-47

APPLICATIONS
dams 48-49
tunnels 50-51

index 11 www.sisgeo.com
CASAGRANDE AND STANDPIPE PIEZOMETERS

WATER LEVEL INDICATOR (WLI)

WATER LEVEL LOGGER (WLL)


PRESSURE
PRESSURE TRANSDUCERS
TRANSDUCERS

Wadi Daiqa Dam - Oman


Casagrande Water Level Water Level
and Standpipe Indicators (WLI) Logger (WLL)
Piezometers

These are simple filter units for measuring water level Dipmeters (WLI) are used for ground water level Water Level Logger (WLL) is an integrated system
in permeable soil. measurements in standpipes, wells and Casagrande designed for automatic continuous monitoring of water
Several models are available for different applications. piezometers. level and temperature inside wells, standpipes and
The Casagrande piezometer is used to measure pore The dipmeter is a battery powered portable device Casagrande piezometers.
water pressure. The open standpipe piezometer is used equipped with a dipping probe connected to a WLL system is equipped with an accurate ceramic
to measure the water table level. graduated cable rolled up on a reel. pressure sensor which provides high accuracy and
The filters are made of high density polyethylene with a When the dipping probe comes into contact with water, long-term stability measurements.
threaded cap joint for two 1/2" tubes or one 1 1/2" tube. it activates either an audible alarm and a light indicator The Water Level Logger records absolute pressure,
Standpipe piezometers are also available as 1 1/2" mounted on the reel faceplate. which is later converted to water level readings by the
slotted tubes wrapped in filtering fabric. The C112T version is also equipped with a dipping Hoboware software using barometric measurements.
A stainless steel push-in filter unit is also available for probe for temperature measurements. A LCD on the reel The optical USB connection interface provide safe and
soft soil installation. faceplate displays the temperature value directly in °C. reliable data download also in bad environmental
conditions.

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS

P101 Casagrande/standpipe 40 μ porous tip MODEL C112 class II flat cable Water level range* 4, 9, 30, 76 m
11/2-inch single tube connection with marks at every millimetre Temp. range -20°C +50°C
Length: 200 mm Probe water level detector Accuracy
Outer diameter: 61.5 mm Available 30, 50, 100 m - water level* ±0.05% F.S.
P112 Casagrande 40 μ porous tip cable lengths 150, 200, 300, 400, 500 m - temperature ±0.5°C
1/
2-inch twin tubes connection Memory type Non-volatile
MODEL C112T class II flat cable
Length: 200 mm with marks at every millimetre Memory capacity 64k-byte
Outer diameter: 61.5 mm Probe water level detector >21.000 combined measurements
Tip pore size: < 40 μ (nominal) and temperature sensor Measuring Interval Programmable
TFH Standpipe filter unit Available 30, 50, 100 m min 1 sec, max 18 hours
PVC slotted tube with fabric cable lengths 150, 200, 300, 400, 500 m Communication port Optical USB interface
Available diameters: 1, 11/2 and 2-inch Temp.operating range -20°C +60°C
Reel diameter 260 mm, 320 mm, 420 mm
Length: 3 meter Battery life*** 5 years typical with min.
Probe diameter 16 mm
measuring interval 1 min.
Display 3.5 LCD (only for C112T)
LOCKABLE CAP * nominal value based on using WLL at sea level
Battery 1 x 9V DC disposable (C112)
(Product code 0P100CH1000) ** typical error using reference level measurement and
2 x 9V DC disposable (C112T)
Equipped with an identification plate and a topographic the barometric compensation
pin, the lockable cap ensures protection at the top end *** depending also from working temperature
of Casagrande and standpipe piezometers. STAFF GAUGES
(Product code 0HIDR100000) HOBOWARE MANAGER SOFTWARE
BENTONITE PELLETS Staff gauges are used for (Product code 0WSBHW10000)
(Product code 1000BE20025K) direct readings of water This software is the next generation software for logger
Supplied in 25 Kg bags, the pellets work as a water- level in reservoirs, rivers management, data graphing and data analysis; it
tight sealant inside the borehole of the and open channels. permits to check the logger status: verify logger set-up
piezometer filter unit. They consist of 1 m long before launch, verify logger operation while logging,
porcelain enameled display real-time sensor readings and display memory
hydrometric rod with used and battery voltage.
centimetre graduation Software's powerful graphing features allows plot and
and reference plate. filter data for a customized data presentation.
Barometric compensation assistant enable you to
compensate water level measurements for barometric
pressure.

PRESSURE TRANSDUCERS 13 www.sisgeo.com


ELECTRICAL PRESSURE TRANSDUCERS

FLOW METERS

VIBRATING WIRE PIEZOMETERS


PRESSURE TRANSDUCERS

Vidraru Dam - Romania


Electrical Pressure Flow Meters Vibrating Wire
Transducers Piezometers

A wide range of electrical piezometers and pressure Water flow monitoring in open channels is widely Vibrating Wire piezometers are strongly recommended
transducers are available for different applications. employed in the environmental and geotechnical fields. for long term monitoring of soil pore pressure or ground
Electrical piezometers and pressure transducers are Leakage measurement is one of the most important water levels.
equipped with a deformable diaphragm with screen indicators of the overall performance of earth/rock-fill The VW piezometer consists of a stainless steel body
printed resistor gauges forming a 4-arms Wheatstone and concrete dams. The leakage rate is a function of equipped with a filter unit (porous stone) and a
bridge. the water level in the reservoir and depends either on pressure sensitive diaphragm with tensioned steel
The P235S piezometers are used to monitor pore the construction and/or the integrity of the dam. wire. The vibrating wire is tensioned inside an
pressure when a fast response, dynamic Consequently, leakage monitoring provides data for the hermetically sealed and vacuum space.
measurements and/or high accuracy are required. evaluation of the long term stability of the dam VW piezometers guarantee fast response, long-term
The model P252A is supplied with a 1/2-inch male construction. stability and immunity to voltage surges (lightning).
thread to be coupled with a hydraulic pressure line (for Leakage water is usually impounded downstream from Readings of VW piezometers are obtained by vibrating
up-lift water pressure monitoring). the dam and diverted to a basin in a weir-station. wire readout or datalogger.
Filter units are available with different porosity: either
HAE (high air entry) and LAE (low air entry) value filters
are suitable for piezometer applications in impervious,
saturated and permeable soils.

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS

MODEL P235S1 with HAE value filter V-NOTCH WEIRS MODEL PK45A with HAE value filter unit
The purpose of the weir is to transform the MODEL PK45S with LAE value filter unit
MODEL P235S4 with LAE value filter instantaneous flow values into the pressure/level by MODEL PK45I drive-in version to be pushed
means of specific measuring equipment. into a soft soil by push-in rods
MODEL P235I Drive-in version to be pushed 0QV45LS1000 10 litre/sec, V-angle 45°
Standard ranges 200, 350, 500, 700 kPa
into a soft soil 0QV60LS2000 20 litre/sec, V-angle 60°
1.0, 1.7, 2.0, 3.5 MPa
0QV90LS5000 50 litre/sec, rectangular
Standard ranges 100, 200, 500 kPa Sensitivity ± 0.025% FS
1, 2, 5, 10, 20 MPa Accuracy < 0.5% FS
Measuring Equipments
Sensitivity 0.01% FS Temp. operating range -20°C +100°C
Accuracy < 0.3% FS QVLIV100 Filter unit features
Temp. Operating range -10°C +55°C LEVEL TRANSDUCER - HAE (100 kPa) 1 μ ceramic stone
Filter unit characteristic (Product code 0QVLIV10000) - LAE stone 40 μ syntherized s/steel
- HAE (100 kPa) 1 μ ceramic stone Transducer type floating unit with 40/50 μ syntherized PE
- LAE stone 40 μ syntherized s/steel high sensitivity load cell Diameter / length 27 mm / 200 mm
40/50 μ syntherized PE Measuring range 1000 mm of water level
Diameter / length 27 mm / 200 mm Sensor resolution 1 mm SATURATION DEVICE
Accuracy better 0.3% FS (Product code 0PF01SAT000)
VENTED PRESSURE TRANSDUCER Output signal 4-20 mA (current loop) The filter saturation is a decisive factor of a successful
The P252R pressure transducer is equipped with a installation of embedded piezometers. Sisgeo provides
vented sensor which provides automatic compensation P251Q100 a device for field use for the saturation of the HAE value
for barometric pressure changes. This transducer LEVEL TRANSDUCER filter (ceramic stone). It consists of a stainless steel
provide ground water table monitoring in Casagrande (Product code 0P251Q10000) pump with manometer and a threaded port to fit the
piezometers, wells and standpipe piezometers. Transducer type pressure transmitter filter unit.
Measuring range 1000 mm of water level
REMOVABLE Accuracy better 0.5% FS
PORE PRESSURE TRANSDUCER Output signal 4-20 mA (current loop)
P252C is a removable pressure transducer for soil pore
pressure monitoring. It is suitable for long-term STAFF GAUGES
monitoring, as the instrument can be removed for 0QVHI030000 300mm long, millimetre division
calibration checks, maintenance or re-used in other 0QVHI050000 500mm long, millimetre division
boreholes. When inserted into the P101 filter unit, the
pressure seal is assured by its conical tip with an O-
ring kept in place on the cable by a string of dead
weights.

PRESSURE TRANSDUCERS 15 www.sisgeo.com


STANDARD INCLINOMETER CASINGS

FLUSH-COUPLED AND QUICK-JOINT INCLINOMETER CASINGS

INCLINO-SETTLEMENT COLUMNS
INCLINOMETERS

Metro Rome Line B1 - Italy


Standard Flush-Coupled Inclino-settlement
Inclinometer Casings and Quick-Joint Columns
Inclinometer Casings

Inclinometer casing is a special grooved tube, generally Flush-coupled inclinometer casing is a special ABS Inclinometer and settlement measurements can be
installed into a borehole, used in conjunction with grooved tube, machined at the end to have a self- combined in a same column. This column consists of
inclinometer system to determine sub-surface ground aligning junction. It is produced from high-quality virgin ABS inclinometer casing equipped with telescopic
or horizontal soil movements. ABS plastic. couplings and magnet rings.
The inclinometer casing performs the following main During manufacturing particular attention is paid to Magnet target rings are available in different model: for
functions: minimise the spiral of the casing grooves and to borehole (spider rings) and for embankment (plate
- it reflects deformations of soil or rock into which it is machine the aligning key for casing junction with self- rings). They are fixed on the inclinometer casing at
installed or in structures to which it is attached; aligning couplings. Casing sections are assembled by stated intervals, depending from the stratigraphy.
- it provides a precise casing for the operation of the means of couplings glued together, riveted and sealed Telescopic couplings are available with a stroke of 75
inclinometer probe in the determination of inclination with special tape. or 150 mm: they provide a constant tracking of the
changes; Sisgeo Quick Joint (QJ) tube is an alternative to the grooves and the possibility to accept axial tube
- its internal grooves provide orientation reference for traditional inclinometer casings, mainly designed for displacement.
the inclinometer probe. earth-fill dams and deep borehole applications. Readings are carried out by vertical inclinometer probe
QJ tube offers simple and fast installation, consistent and magnet detector probe for a 3-D vertical survey.
Inclinometer casing is produced in different materials
joint and deeper tube grooves. O-rings prevent ingress
as aluminium, fibreglass and ABS (Acrylonitrile-
of grout or water. The fitted-at-factory casings and the
Butadiene-Styrene).
alignment keys assure a perfect grooves continuity.

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS

ALUMINIUM FLUSH-COUPLED Accessories for inclino-settlement columns


(Model code S111) (Model code S141) 0S141ST0700 TELESCOPIC SECTION FOR S141
S1110075 S1110054 Tube outer diameter 70 mm 3 meter section with 75 mm gap
Material Aluminium Aluminium Tube inner diameter 59 mm 0S141ST1500 TELESCOPIC SECTION FOR S141
Tube outer diameter 86.4 mm 58.0 mm Tube groove inner diam. 61,5 mm 3 meter section with 150 mm gap
Tube inner diameter 76.1 mm 49.0 mm Thickness 5,5 mm 0S151MT0700 TELESCOPIC COUPLING FOR QJ
Tube groove inner diameter 82.0 mm 54.0 mm Casing length 3 meter length 500 mm with 75 mm gap
Thickness 2.2 mm 2.0 mm Casing colour white 0S131AF6000 SPIDER MAGNET RING, ID 71MM
Casing length 3 meter 3 meter Weight 1.2 kg/meter Large (2.75" OD tube)
Weight 1.4 kg/m 0.92 kg/m Material ABS plastic 0S131AR6000 EMBANK. MAGNET RING, ID 71MM
Spiral <1.0°/ 3 m <1.0°/ 3 m Spiral < 0.6°/3 meter Plastic plate OD 300 mm
Coupling outer diameter 92.0 mm 62.6 mm Collapse test (*) 15 bar 0S151AF8000 SPIDER MAGNET RING, ID 83MM
Coupling length 300 mm 300 mm Temperature range - 20°C + 80°C Large (3.25" OD tube)
Coupling outer diameter 70 mm 0S151AR8000 EMBANK. MAGNET RING, ID 83MM
ABS Coupling length 200 mm Plastic embank. plate OD 300 mm
(Model code S131) 0S141DR7000 DATUM REFERENCE SECTION FOR S141
Material ABS
QUICK-JOINT (QJ) Magnet ring and bottom cap
Tube outer diameter 71.0 mm
(Model code S151) 0S151DR7000 DATUM REFERENCE SECTION FOR QJ
Tube outer diameter 70 mm
Tube inner diameter 60.0 mm Magnet ring and bottom cap
Tube inner diameter 59 mm
Tube groove inner diameter 64.0 mm
Tube groove inner diameter 62.5 mm
Thickness 3.5 mm
Thickness 5.5 mm
Accessories for inclinometer tubes
Casing length 3 meter
Overall section length 3100 mm Top / bottom cap Simple caps to prevent tube clogging.
Weight 0.7 kg/m
Overall diameter 84 mm Lockable top cap Protective cap with identification plate
Spiral <0.6°/ 3 m
Colour white/red and topographical survey pin.
Coupling outer diameter 77.0 mm
Spiral <0.6°/3m Designed for fitting the pulley assembly.
Coupling length 200 mm
Collapse test (*) 15 bar Assembly kit Provides cement, pop rivets, sealing
Temperature range -20°C +80°C tape and adhesive tape.
(*)Tests are performed in a water pressure chamber with an Bottom grout valve Permits grouting through the casing by
empty casing sealed at the two ends. means of a removable injection valve.

INCLINOMETERS 17 www.sisgeo.com
INCLINOMETERS PROBES

ARCHIMEDE INCLINOMETER DATALOGGER

TILLI PORTABLE TILTMETER


INCLINOMETERS

Mazar Hydroelectric Project - Ecuador


Inclinometer Archimede Tilli
Probes Datalogger Portable Tiltmeter

The inclinometer probe measures tilt deviations within Archimede datalogger has been designed to read data TILLI is a portable tiltmeter. It consists of a durable
the vertical inclinometer casings. This allows the and show graphs from the following Sisgeo removable stainless steel frame with an aluminium housing
monitoring of lateral movements. probes: horizontal and vertical inclinometers, T-REX, containing a force-balanced servo-accelerometer sensor.
Inclinometer probe model S242SV30 is equipped with a spiral-meter and TILLI portable tiltmeter. The surfaces of the frame are machined to allow an
±30° range biaxial, force-balanced servo accelerometer Archimede is a battery operated datalogger with a accurate positioning of the tiltmeter during
which provides a high level of precision, durability and large graphic color backlight display, housed in a measurements.
quick response. crushproof, water-resistant plastic case. This In use, the TILLI is placed on the tilt plate which is
Sisgeo inclinometer probes can be used in conjunction datalogger has been specially designed for field use in permanently installed on the surface of the structure.
with all commercially available inclinometer casings heavy operating conditions. A convenient remote hand- Measurements can be taken on horizontal or vertical
with ID grooves from 38 mm to 84 mm. switch allows one-man surveys. surfaces. The bottom surface of the tiltmeter is used with
A durable anti-shock plastic ABS carrying case is Archimede could be supplied with a Bluetooth interface horizontally-mounted tilt plates, while the side surface is
provided for transportation and storage of inclinometer in order to sent stored data to the office by means of used with vertically mounted tilt plates. Again,
probed, as well as the dummy probe. Readings are smartphone. measurements can be taken on horizontal or vertical
obtained by Archimede portable datalogger. SMART Manager Suite is the software package surfaces.
designed by Sisgeo that permits to manage Archimede Readings in two orthogonal directions can be obtained
directly on you PC, automatically update FW and SW rotating the instrument 90° on the horizontal surface.
and obtain on-line technical assistance. Coniugated measurements (180 degrees rotation)
eliminate instrumental and mounting offset.

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS

Measuring range ±30° A/D converter 2 x 24 bit,with autocalibration TILLI sensor uniaxial force-balanced
±15° and ±90° option Storage memory 2 GB servo-accelerometer
Non-linearity + hysteresis 0.02% FS Display color graphic TFT, LED backlight Measuring range ±14.5° from the vertical
0.06% FS for ±90° probe COMM port USB (“pen-drive” stile) Sensor resolution better than 0.001° with both
Repeatability 0.01% FS Temperature oper. range: -20 - +60 °C, IP67 LEONARDO and CRD-400 readouts
Temp. Operating range -20°C +70°C System Dimensions (LxWxH) 200 x 280 x 65mm Total accuracy better than ±0.04% FS
Accuracy ±4mm per 30meter (linearity, hysteresis, repeatability)
(with ARCHIMEDE readout) INCLINOMETER Scale thermal
Wheel base 500mm (metric) OPERATING CABLE factor sensitivity ±0.002% FS/ °C
2-foot (English) Abrasion and chemical-resistant, Signal output ±5 V at FS
Diameter 28mm the inclinometer operating cable is Compensated temp. range -20°C +60°C
Length 750mm (without connector) used to control the depth of the Material stainless steel frame
Wheel diameter 32mm inclinometer probe. The stainless steel anodised AL sensor housing
shield, that is molded to the external Weight 3 Kg (TILLI only)
HORIZONTAL PROBE polyethylene (PE) jacket, eliminates any cable Carrying case IP68 shock-resistant plastic
(Product code 0S241HH3000) twisting, and a stainless steel core wire
Equipped with uniaxial solid-state accelerometer, this controls any stretching of the cable itself.
probe is designed for measurements in horizontally- An internal binder eliminates slipping of the
installed inclinometer tubes. single conductor relative to the external PE
jacket. Additionally, copper rings are crimped
Measuring range ±30°
on the external PE cable jacket for tactile
Repeatability 0.05% FS
operations. The operating cable includes
Diameter 28 mm
Length 750mm (without connector)
the submersible probe mating connector TILT PLATE
which allows a monitoring distance of up to (Product code 0SCLTP14B00)
200m water depth. Material bronze
SPIRAL PROBE
Cable lengths: 30, 50, 60, 100, 150, 200m Diameter 135 mm
(Product code 0S30PR12000)
100', 200', 300', 400', 500’(English) Stainless steel cover available as option
The Spiral Probe is used to define the real azimuth of
Graduation 500mm (metric), 2-foot (English) (product code 0SCLTC14000)
the inclinometer casing after installation. It provides
measurements that can be used to correct the data
obtained from twisted inclinometer tubes. The spiral
PULLEY ASSEMBLY
(Product code 0S1CSU10000)
probe is fully compatible with the inclinometer
This simple and useful pulley assembly monitors depth
operating cable and Archimede portable datalogger.
measurements during the process of obtaining
Measuring range ±5° over the probe length inclinometer measurements. The device also protects
Resolution 10 mV/ ° the cable from abrasion. The assembly consists of a
Accuracy < 0.5% FS pulley, cable stop and adaptors to suit different casing
Diameter 28mm diameters.
Length 1.263mm (without connector)

INCLINOMETERS 19 www.sisgeo.com
IN-PLACE INCLINOMETERS (IPI)

RDS SYSTEM (RAILWAY DEFORMATION SYSTEM)

SURFACE CLINOMETERS AND BEAM CLINOMETERS


INCLINOMETERS

Fontanellato Tunnel - Italy


In-place Rds System Surface Clinometers
Inclinometers (ipi) (Railway Deformation System) and Beam Clinometers

In-Place Inclinometer (IPI) sensors are designed RDS (Railway Deformation System) is aimed to monitor Surface clinometers are tilt sensors used to measure
for automatic monitoring of critical locations. Jointed the longitudinal deformation and torsion of railway tracks. changes in the inclination of structures. They are
together and suspended inside the casing where For the longitudinal deformation, the system is permanently installed on the controlled surface and
deformation may occur, a string of IPI sensors allows composed by a chain of aluminium bars instrumented they could be read both by manual readout or with
the operator to monitor the profile of the inclinometer with a built-in solid-state accelerometer sensor (MEMS automatic data acquisition system for long term
casing on a continuous basis. technology). monitoring.
Vertical and horizontal in-place inclinometers are In order to measure the track torsion (cant), the Surface clinometers are available in uniaxial and biaxial
available in uniaxial and biaxial versions, equipped with sleepers are monitored with an inclinometer sensor versions, equipped with solid-state accelerometer
solid-state accelerometer or force-balanced servo- mounted perpendicularly to the railway. (MEMS technology) or force-balanced servo-
accelerometer sensors. All RDS sensors are furnished with a built-in thermistor accelerometer sensors.
Separated signal cables are required for each sensor. in order to have a relationship between inclination and The family line of S520 clinometers is housed in a
However, several in-place inclinometers can be linked environment thermal effect. durable stainless steel cylinder, IP68 water-resistant up
together in order to create a single multi-core cable RDS system shall be continuously monitored by means to 200 kPa. A spirit level, adjustable mounting bracket
output. Horizontal in-place inclinometers are widely of ADK-100 system that transmit data through GPRS and anchor plate are included.
used in monitoring the deflection of the up-stream face modem to a remote server where the web platform Beam clinometer is a tiltmeter designed to measure
of dam slopes. WMS is running. angular displacement. It consists of a solid-state tilt
sensor (MEMS technology) engineered into an aluminium
beam, with available in different lengths of 1, 2, or 3 m.

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS

MODEL S411HA uniaxial solid-state LONGITUDINAL RDS COMPONENTS FORCE-BALANCED SERVO-ACCELEROMETER


accelerometer (MEMS) 0S7RDS10L30 RDS instrumented bar, 3m length, Measuring ranges ±10°, ±14.5°, ±30°
MODEL S412HA biaxial solid-state for longitudinal deformation track Total accuracy better than ±0.07% FS
accelerometer (MEMS) monitoring. It mount also a Scale thermal ±0.002% FS/ °C
topographic target and spirit level. factor sensitivity
Full scales ±10°, ±20°
0S7RDS10L20 RDS instrumented bar, 2m length Excitation voltage ± 15V DC ± 1%
Sensor resolution 0.01% FS
0S7RDS10L10 RDS instrumented bar, 1m length Signal output ± 1.5 V, ± 5 V at FS
Total accuracy better than ±0.4% FS
0S7RDS00AN0 Angular support and chain terminal. Temp. operating range - 20°C to + 80°C
Scale thermal ±0.01% FS/ °C
factor sensitivity
TRASVERSAL RDS COMPONENTS SOLID-STATE ACCELEROMETER (MEMS)
Signal output 4-20 mA
0S7RDS10T10 RDS instrumented bar, 1m length, Full scales ±10°, ±20°
Comp. temp. range -25°C +80°C
for track torsion monitoring. Total accuracy
MODEL S411SV uniaxial force-balanced 0S7RDS10T02 RDS sensor for pre-cast concrete - with linear factor ±0.4% FS
servo-accelerometer sleeper tilt monitoring - with polynomial factor ±0.15% FS
MODEL S412SV biaxial force-balanced Excitation voltage from 8 to 30V DC
servo-accelerometer Signal output 4-20 mA
Technical specifications Temp. operating range - 40°C to + 85°C
Measuring ranges ±14.5°, ±30° Sensor type uniaxial solid-state accelerometer
Sensor resolution 0.001% FS Measuring range ±10° BEAM CLINOMETER
Total accuracy better than ±0.07% FS Total accuracy (Product code 0S700TL10H0)
Scale thermal ±0.002% FS/ °C - with linear factor ±0.4% FS Sensor type uniaxial solid-state accelerometer
factor sensitivity - with polynomial factor ±0.15% FS Measuring range ±10°
Signal output ±5 V at FS Signal output 4-20 mA Total accuracy
Comp.temp. range 0°C +50°C Temperature operating range -40°C to +85 °C - with linear factor ±0.4% FS
Temperature sensor NTC thermistor - with polynomial factor ±0.15% FS
PROBE FEATURES Housing aluminium, IP67 Signal output 4-20 mA
Overall diameter 30 mm Temperature operating range -40°C to +85 °C
Wheel base 1000 mm Support bars:
Material s/steel and thermoplastic resin Dimension 40x60mm section, 1, 2, 3m length Supports:
Cable connection epoxy sealed up to 200 kPa Material aluminium 0S7BM000000 Aluminium bar, section 40x60mm,
available with lengths of 1, 2 or 3 m
Accessories 0S700TLLS00 Angle support
0S4TS101000 In-place inclinometer support head 0S700TLP000 Welding plate
0S4IPITOOL0 In-place inclinom. clamping tool 0S700TLLSR0 Adjustable angle support for mounting
0WRAC200000 stainless steel support wire, 2 mm on inclined plane

INCLINOMETERS 21 www.sisgeo.com
MAGNET EXTENSOMETER (BRS)

T-REX REMOVABLE EXTENSOMETER

IN-PLACE EXTENSOMETERS AND EXTENSO-INCLINOMETERS


SETTLEMENT GAUGES

Metro Rome TBM Tunnel - Italy


Magnet T-rex Dex
Extensometer (BRS) Removable In-place Extensometers
Extensometer

The magnet extensometer is a system, based on British T-REX is a removable extensometer which has been DEX extensometers are used in conjunction with flush-
Building Research techniques, for measuring either designed for incremental measurements along the axis coupled ABS inclinometer casings for automatic
settlement or heave at various depths in soil, of inclinometer casing equipped with targets. monitoring of settlement or heave.
embankments, earthfill dams and dikes. The T-REX probe is equipped with a contactless Strings of DEX extensometer are joined together with
The system consists of an access tube with external magnetostrictive linear transducer. Operating cable, stainless steel wire or bars. DEX probes can be placed
corrugate pipe, magnet rings, as well as a telescopic placement rods, portable readout and T-REX analyzer at different depths where the settlement occurs with
bottom section with datum ring and suspension head. software are provided. reference points at the top or bottom of the casing.
Magnet rings (targets) are positioned externally to the Utilization of the Archimede portable readout is suitable DEX-S model is also equipped with biaxial tilt sensors;
access tube, and then placed in the ground where for tracking readings with T-REX probes. Through the it permits 3-D borehole profile monitoring.
movements may occur. Magnet rings move together USB port, the measurements can be easily transferred ADK-100 datalogger equipped with GSM module
with the surrounding soil along the axis of the access to a PC for data management. provides automatic monitoring of unattended locations.
tube. T-REX analyzer software allows the operator to
Readings are obtained with a portable unit linked to the computer displacement measurements line-wise per
reed switch probe that is lowered down the access meter of distance, both in vertical and horizontal
tube. Comparison of data taken, over time provides installations.
profiles of ground settlement or heave.

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS

System Components T-REX extensometer offers several advantages: DEX PROBE


0D111P30000 3M SECTION ACCESS TUBE - wide measuring range (±100mm displacement every 0DEX35010000 Range 100 mm, base 1000 mm
0D111P15000 1.5M SECTION ACCESS TUBE per meter) which allows applications either in soil or rock 0DEX35050000 Range 500 mm, base 1000 mm
0D111PV5500 CORRUGATED PIPE, OD 55mm - fully compatible with Sisgeo inclinometer operating 0DEX35100000 Range 1000 mm, base 1500 mm
0D111TF6000 TELESCOPIC END AND DATUM cable, connector and readout
Sensor resolution 0.01mm
0D111TS1000 SUSPENSION HEAD - no-mechanical contact between probe and targets
System accuracy 0.25% FS
0D111AF6000 SPRING MAGNET RING - combined with inclinometer measurements permits
Repeatability 0.02mm
ID 60mm, max span 300mm 3-D deformation borehole profile
Signal output 0-10V DC
0D111AR6000 MAGNET SETTLEMENT PLATE
Measuring base 1.000 mm Operating temperature -20°C +60°C
iD 60mm, plate OD 300mm
Measuring range ± 100 mm Environmental IP68 (up to 1.5 MPa)
Probe accuracy ± 0.02 mm Outer diameter 35mm
C121 PORTABLE READOUT
Reading resolution 0.01 mm
MAGNET DETECTOR PROBE UNIT
0C121005000 READOUT, 50M FLAT CABLE
Operating temperature -10°C +60°C DEX-S PROBE
Enviromental IP68 up to 1.5 MPa With biaxial tilt sensor
0C121010000 READOUT, 100M FLAT CABLE
Dimensions OD 40mm, length 1530 mm 0DEX35S102B0 Tilt range ±10°
0C121015000 READOUT, 150M FLAT CABLE
Material s/steel, brass and aluminium 0DEX35S202B0 Tilt range ±20°
0C121KITR00 DIPPING PROBE SPARE KIT
Probe dimensions OD 16 mm, length 250 mm Extensometer range 100 mm
Cable division millimetre, class II ECC
PORTABLE READOUT
Measuring base 1000 mm
Measurements are performed by Archimede dataloggers
Cable sheath nylon Probe length 1170 mm
equipped with external battery pack (Product Code
System accuracy ±1 mm
0CDL012EXBP0). The battery pack is sealed in a water-
Temp. operating range -40°C +80°C
resistant case, which is connected to the portable
Tilt Sensor
Type Biaxial solid state accelerometer
readout unit when the operator performs measurement
HORIZONTAL DISPLACEMENT MAGNET SYSTEM Resolution 0.01% FS.
functions.
Magnet system can be installed horizontally to Thermal sensitivity ± 0.01% F.S./°C.
A/D converter 2 x 24 bit, with autocalibration
measure horizontal ground movements. Total accuracy < 0.4% F.S.
Storage memory 2 GB
0TUHDPE5000 HDPE ACCESS TUBE, OD 50mm
Display color graphic TFT, LED backlight
0D111PV7000 CORRUGATED PIPE, OD 70mm Accessories
320x240 pixel, sunlight reliability
0D1RINV4000 DEAD END PULLEY ASSEMBLY 0S4TS101000 In-place probe support head
COMM port USB
0D111AH6500 MAGNET RING ID 70mm 0WRAC200000 Stainless steel support wire, 2 mm
Temperature oper. range: -20 - +60 °C, IP67
0S4IPITOOL00 Wire clamping tool
Dimensions (LxWxH) 200 x 280 x 65mm
0REX0RING93 T-REX magnetic ring
ID 71mm, OD 95mm.

SETTLEMENT GAUGES 23 www.sisgeo.com


DSM BUILDING SETTLEMENT MONITORING SYSTEM

HYDROSTATIC PROFILE GAUGE (PROFILER)

DSM SETTLEMENT GAUGES


SETTLEMENT GAUGES

Puerta Del Sol, Madrid - Spain


Dsm System Hydrostatic Dsm Settlement
Profile Gauge Gauges
(Profiler)

The DSM Differential Settlement Monitoring System has Profiler is a hydrostatic profile gauge designed for The measured soil settlement of ground or
been developed by Sisgeo for automatic and continuous settlement or heave monitoring beneath embankments embankments is of primary importance for monitoring
long-term monitoring of differential settlements or heaves or foundations. the structural stability during construction works.
of buildings and structures. The system consists of a settlement probe equipped Two types of DSM settlement gauges are available:
The DSM structure system consists of a series of DSM with a high sensitive pressure transducer connected by D422R model for embankment and D422F model for
tank-gauges interconnected by a small hydraulic tube to a a liquid-filled tube to a reservoir. borehole.
reference tank, which is located on a firm point away from The Profiler probe is pulled - meter by meter - through Depending on the type of application, the settlement
the area that is going to be monitored. a HDPE pipe buried in fill, embankment, etc. The liquid gauges are installed in different configurations, linked
The hydraulic tube is filled by a de-aired mixture of 50% tube is rolled up on a reel. together by a hydraulic line to a reference gauge and
glycerine (99%) and 50% water. This mix is usually The transducer measures the profile of the pipe relative connected to an automatic data acquisition system.
supplied by Sisgeo and is chemically inert to all to the reservoir located on a tripod mounted on stable The operating principle is based on the pressure
components in the system. ground. On the reel face panel, the LCD displays direct variation caused by the change in height of a column of
The measurement of fluid level inside each DSM tank readings in millimeters. liquid. Subsequent height variations occurring between
indicates the elevation difference between the sensors the datum point and the measuring points cause
and the reference tank. proportional variations of the hydraulic level at each
settlement gauge.

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS

DSM LEVEL GAUGE PROFILER PROBE EMBANKMENT GAUGES


(Product code 0D422M08000) (Product code 0D5HPG33100) (Product code 0D422R00000)
Type of sensor high sensitivity load cell Measuring range 8.5 m Measuring range 8.5, 17.0, 43.5, 87.0 m
Measuring range ±40mm water level Resolution 1 mm (with Sisgeo liquid mix)
Sensor sensitivity 0.01mm Total accuracy ±20 mm Sensor sensitivity 0.01% FS
Sensor accuracy ±0.1mm (thermal effects not included) Time lag 3-10 sec Sensor accuracy <0.3% FS
Difference in elevation straight-horizontally Diameter 34 mm Output signal 4-20 mA
Housing dimensions 400x300x200mm Length 280 mm
Material stainless steel VW EMBANKMENT GAUGES
DSM LONG RANGE LEVEL GAUGE (Product code 0D422R000VW)
(Product code 0D422L08500) Readout and reel Measuring range 15.0, 31.0 m
(with Sisgeo liquid mix)
Type of sensor linear potentiometer Digital display 4.5 digits LCD
Sensor sensitivity 0.025% FS
Measuring range 800mm A/D converter 14 bits + sign
Sensor accuracy <0.5% FS
Sensor sensitivity 0.01mm Reading accuracy ±1 digit
Output signal Frequency
Sensor accuracy ±0.5mm (thermal effects not included) Zero off-set adjustable
Difference in elevation up to 800mm Power supply 12V DC rechargeable battery
Housing dimensions OD 68mm, 1050mm high Operating time 15 hours
BOREHOLE GAUGES
(Product code 0D422F00000)
Temp. operating range -10°C +50°C
Measuring range 8.5, 17.0, 43.5, 87.0 m
DSM systems are very sensitive to temperature changes. Reel diameter 690 mm
(with Sisgeo liquid mix)
Accurate measurements require that temperatures be Reel cable capacity < 150 meter
Sensor sensitivity 0.01% FS
monitored at sensor locations. Data is processed utilizing Total weight 25 Kg with 50 m tube
Sensor accuracy <0.3% FS
“Fieldstat” software.
Output signal 4-20 mA
PROFILER CABLE
(Product code 0WE206KE000) Components and Accessories
Profiler cable includes electrical cable and liquid tube 0D422S08000 DSM REFERENCE GAUGE
encapsulated in a common PVC external jacket. 0D422SERB00 DSM REFERENCE TANK
Electric cable 6-cond. with reference tube
0TUPE060800 6MM PE TUBE, ID/OD 6/8mm
Liquid tube diameters ID 6mm, OD 8mm
0TUPE101200 10MM PE TUBE, ID/OD 10/12mm
Liquid type de-aired water-glycerine mix
1000COPE300 HYDRAULIC TUBE INSULATION
Marks every meter
1000LIGL100 WATER-GLYCERINE MIX
External jacket PVC, OD 12.8 mm
0D422SAT200 DSM SATURATION DEVICE, 20lt.

SETTLEMENT GAUGES 25 www.sisgeo.com


EARTH PRESSURE CELLS

NATM STRESS CELLS

HYDRAULIC PRESSURE CELLS


PRESSURE & LOAD CELLS

Chuquicamata Mine - Chile


Earth Natm Hydraulic
Pressure Cells Stress Cells Pressure Cells

Earth pressure cells are utilized to monitor the total Sisgeo flexible diaphragm NATM Stress Cells have Hydraulic pressure cells are designed to measure
pressure in earthfill dams and embankments or at the been designed to optimize measurements of radial and stress in mass concrete or at the interface between the
interface between the structure and the excavation wall. tangential stresses in shotcrete and concrete tunnel structure and the excavation wall.
The earth pressure cells consist of two stainless steel lining. The pressure pad consists of two steel plates welded
plates, welded together around their pheriphery. The The stress cell consists of a pressure pad connected to together around their periphery, spaced apart by a
anular space between these plates is filled, under the transducer by a hydraulic line. The internal cavity narrow cavity saturated (under vacuum) with de-aired
vacuum, with de-aired oil. between the two steel plates of the pressure pad and oil. This guarantees maximum rigidity.
The pressure pad is connected via a stainless steel the hydraulic line is filled at factory with oil. The oil is A length of high-pressure rilsan tubing connects the
tube to the transducer, forming a closed hydraulic deaired as well as the pressure pad under high vacuum cavity of the pressure pad to the pressure transducer. A
system. in order to obtain the minimum oil compressibility. re-pressurizing device is available for expanding the
The stress is then converted to an electrical signal and The rigidity of the cells are assured by the transducer, cells after the concrete has cured.
may be remotely read on a variety of portable readout which has a ceramic diaphragm with negligible volume Readings are obtained with portable readout units or
units or dataloggers. displacement in comparison with the cell cavity. dataloggers.

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS

VIBRATING WIRE SENSOR RADIAL STRESS CELL PRESSURE PADS


L143D (circular) (Product code 0L112R05000) 0L111151500
L143S (rectangular) Measuring range 0-5 MPa (50 Bar) Pad size 150X150 mm
Full scales 350, 500, 700 kPa Resolution 0.01 MPa with C6002 Working pressure up to 5 MPa
1, 1.7, 2, 5, 7 MPa Accuracy < 0.3% FS Application radial stress in concrete
Resolution 0.025% FS Pressure pad size square 150x150mm
Accuracy < 0.5% FS Pad thickness 5 mm 0L111102000
Pressure pad size circular OD 230 mm Transducer size OD 25mm, 130mm long Pad size 100x200 mm
rectangular 100x200mm Working pressure up to 20 MPa
Operating temp. range -20°C +80°C TANGENTIAL STRESS CELL Application tangential stress in concrete
Pad thickness circular 12 mm (Product code 0L112T20000)
rectangular 6 mm Measuring range 0-20 MPa (200 Bar) 0L111204000
Transducer size OD 27mm, 180mm long Resolution 0.01 MPa with C6002 Pad size 200x400 mm
Accuracy < 0.3% FS Working pressure up to 5 MPa
ELECTRIC TRANSDUCER Pressure pad size rectangular 100x200mm Application contact soil/rock-structure
L141D (circular) Pad thickness 5 mm
L141S (rectangular) Transducer size OD 25mm, 130mm long 0L111D05000
Full scales 200, 500 kPa, 1, 2, 5, 10 MPa Pad size circular 500mm OD
Resolution 0.01% FS C6002 DIGITAL INDICATOR Working pressure up to 1 MPa
Accuracy < 0.3% FS (Product code 0C6002MV000) Application contact soil/rock-structure
Output signal 4-20 mA current loop Digital display 3.5 LCD
Pressure pad size circular OD 230 mm Resolution 10 kPa (0.01 MPa) PK45H VW PRESSURE TRANSDUCERS
rectangular 100x200mm Battery 9V DC alkaline disposal Full scales 350, 500, 700 kPa,
Operating temp. range -10°C +55°C Operating time 2 hours continuously 1, 1.7, 2, 5, 7 MPa
Pad thickness circular 12 mm Environmental -5°C +50°C, dust-proof case Resolution 0.025% FS
rectangular 6 mm Size 130x75x40 mm Accuracy < 0.5% FS
Transducer size OD 27mm, 180mm long Operating temp. range -20°C +80°C
REPRESSURIZING DEVICE Transducer size OD 27mm, 180mm long
(Product code 0L111PUMP00)
This device allows the operator to increase the P252A PRESSURE TRANSDUCERS
hydraulic oil pressure inside the cavity of the cell for Full scales 200, 500 kPa, 1, 2, 5, 10 MPa
maintaining close contact between the pressure pad Resolution 0.01% FS
and the surrounding material or for expanding the cells Accuracy < 0.3% FS
after the concrete has cured. Output signal 4-20 mA current loop
Operating temp. range -10°C +55°C
Transducer size OD 27mm, 180mm long

PRESSURE & LOAD CELLS 27 www.sisgeo.com


HYDRAULIC ANCHOR LOAD CELLS

ELECTRICAL ANCHOR LOAD CELLS

STEEL LINING AND SOLID LOAD CELLS


PRESSURE & LOAD CELLS

Bridge on Dnieper River - Ukraine


Hydraulic Electrical Steel Lining
Anchor Load Cells Anchor Load Cells Load Cells

Hydraulic anchor load cells are utilized to monitor loads Electrical resistance anchor load cells consist of a ring- Steel lining load cells are specially designed to monitor
in tiebacks, rock bolts and cables. shaped stainless steel body which incorporate from 8 steel lining stress and pile testing.
They consist of two ring-shaped stainless steel plates to 16 electrical resistance strain gauges in a full bridge The L2CE model consists of a stainless steel cylinder
welded together around their edge. The pressure pad configuration. body with a pressure transducer. The pressure pad is
between the plates is filled, under high vacuum, by de- Typical applications include performance testing of realized by two stiff stainless steel plates and is
aired oil. anchor systems in tunnelling or deep excavations. The saturated, under vacuum, with de-aired oil. Special
The load is directly measured by a Bourdon manometer cell design minimizes the sensitivity to the eccentric distribution plates with spherical surfaces are available
connected to the cell body. The manometer is calibrated load. to improve the quality of the measurements.
in the lab to allow direct readings in kN. Electrical models Anchor load cells are available in a variety of ranges Electrical Resistance Load Cells are designed to
equipped with 4-20 mA output pressure transducer are and diameters. A very stiff distribution plate is supplied, perform pile testing and to monitor load compression of
also available for remote readings. in order to ensure that the load is applied equally over struts, tiebacks and arch supports.
A very stiff distribution plate is supplied, in order to the anular loading surface of the cell. The L2CT model consists of a solid cylinder body
ensure that the load is applied equally over the loading Readings are obtained with a CRD-400 hand held manufactured from high tensile, heat-treated steel with
surface of the cell. A bearing plate may not be required readout, Galvani readout or Leonardo datalogger. precision bearing surfaces. It incorporates from 4 to 8
if adequate provisions have been incorporated into the electrical strain-gauges, in full bridge configuration.
installation design.

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS

HYDRAULIC LOAD CELLS 0L204V03000 300 KN, ID 40mm, OD 155mm L2CE STEEL LINING LOAD CELLS
WITH HORIZONTAL MANOMETER 0L205V05000 500 KN, ID 50mm, OD 155mm 0L2CE019000 1900 KN, OD 191 mm
0L2M07050H0 500 KN, ID 71mm, OD 164mm 0L207V07500 750 KN, ID 71mm, OD 155mm 0L2CE030000 3000 KN, OD 245,5 mm
0L2M09075H0 750 KN, ID 92mm, OD 204mm 0L211V07500 750 KN, ID 110mm, OD 200mm
Accuracy < 1% FS
0L2M11100H0 1000 KN, ID 110mm, OD 228mm 0L212V10000 1000 KN, ID 120mm, OD 220mm
(linearity, hysteresis and repeatibility)
0L2M13100H0 1000 KN, ID 138mm, OD 245mm 0L216V12000 1200 KN, ID 165mm, OD 260mm
Signal output 4-20 mA (current loop)
0L2M16150H0 1500 KN, ID 165mm, OD 293mm 0L216V15000 1500 KN, ID 165mm, OD 260mm
Temp. operating range from –20° to +80°C
0L2M22250H0 2500 KN, ID 225mm, OD 380mm 0L219V18000 1800 KN, ID 190mm, OD 300mm
Protection Class IP 68 up to 100 KPa
0L222V25000 2500 KN, ID 225mm, OD 340mm
Overload 120% with zeroshift <2% FS Material stainless steel
Resolution < 0.2% FS Full scales from 300 KN to 2500 KN
Accuracy ± 1% FS Overload 150% DISTRIBUTION PLATES
Temperature error < 1.5% FS Sensitivity 0.01 mV/V Sisgeo L2CE cells are specially designed for steel lining and
at 25°C temperature difference Accuracy < 0.5% FS pile testing applications.
Material AISI 304 stainless steel Thermal zero shift < 0.005% FS / °C 0L2CE200PD0 Twin plates, overall diam. 200mm
Signal output 1.5mV/V, 2 mV/V at FS, 0L2CE252PD0 Twin plates, overall diam. 252mm
HYDRAULIC LOAD CELLS Power supply from 2V DC to 10V DC
WITH ELECTRICAL TRANSDUCER Output bridge resistance 1400 ohm L2CT SOLID LOAD CELLS
0L2E0705000 500 KN, ID 71mm, OD 164mm Compens. temp. range -10°C +60°C 0L2CT030000 3000 KN, OD 135 mm
0L2E0907500 750 KN, ID 92mm, OD 204mm Operating temp. range -15°C +70°C 0L2CT050000 5000 KN, OD 180 mm
0L2E1110000 1000 KN, ID 110mm, OD 228mm Material stainless steel
Overload 150%
0L2E1310000 1000 KN, ID 138mm, OD 245mm
Sensitivity 0.01% FS
0L2E1615000 1500 KN, ID 165mm, OD 293mm DISTRIBUTION PLATES
Accuracy 0.2% FS
0L20040PD00 centre hole 40mm, OD 110mm
Overload 120% with zeroshift <2% FS Thermal zero shift < 0.005% FS / °C
0L20050PD00 centre hole 50mm, OD 110mm
Resolution from 0.03% FS to 0.09% FS Signal output 2 mV/V at FS
0L20071PD00 centre hole 71mm, OD 110mm
Accuracy ± 1% FS Temp. operating range -40°C +75°C
0L20110PD00 centre hole 110mm, OD 155mm
Temperature error < 1.5% FS Compensated temp. range -20°C +60°C
0L20120PD00 centre hole 125mm, OD 180mm
at 25°C temperature difference Protection Class IP 65
0L20165PD00 centre hole 165mm, OD 210mm
Material AISI 304 stainless steel Material steel UR-40
0L20190PD00 ID 165mm, OD 250mm
0L20225PD00 centre hole 231mm, OD 290mm

Accessories
0ECONO7MV00 MIL male connector with cap
0ELC420MA00 4-20 mA transmitter (2 wires)

PRESSURE & LOAD CELLS 29 www.sisgeo.com


DIGITAL TAPE EXTENSOMETER

MECHANICAL JOINTMETERS

DBS MEASURING ANCHORS


EXTENSOMETERS & JOINTMETERS

Milan Metro Line 5 - Italy


Digital Mechanical DBS
Tape Extensometer Jointmeters Measuring Anchors

Tape extensometer is used to take accurate distance A wide range of mechanical crackmeters (jointmeters) Measuring anchors are a combination of rock bolt and
measurements between pairs of target points that have are produced in order to satisfy all client’s extensometer. They are used to evaluate the
been permanently installed. requirements. performance of rock anchors in all types of applications.
The instrument is a removable stainless steel The removable extensometer allows the measurement Measuring anchor consists of a hollow anchor body with
measuring tape with equally-spaced punched holes of relative movements between two reference pins inside installed a 4-point mini extensometer with anchor
incorporated in an aluminium and stainless steel body positioned across the joints (fissure). The extensometer, points at 4 different levels.
with external pneumatic tensioning device and which comes with its own portable, storage case, has Sisgeo measuring anchor is available for nominal load
incorporated dial gauge. a precise sliding rail with length adjustable base. of 250KN with lengths of 4,6 or 9 meters.
At the same time, the tape extensometer provides Uniaxial and 3-D (triaxial) mechanical jointmeters are Readings are taken manually by a dial gauge or could
constant tension on the tape and accurate readings on also available to monitor joints and cracks. The be also automated by using vibrating wire displacement
the dial gauge. A portable compressor provides movements between the two anchors are obtained with transducers.
compression air to adjust the tape tension during mechanical dial gauges.
measurements. Simple and inexpensive, the TT-1 tell-tale crack
Typical applications include convergence monitoring of monitor installed across a fissure allows the crack
tunnel linings, according to NATM practice, and of survey to be conducted in two directions.
shafts, underground openings and caverns.

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS

0DNP0150000 15 M TAPE REMOVABLE EXTENSOMETER 0DBS2503244 DBS 4M LONG


0DNP0300000 30 M TAPE (Product code 0DF250C5000) 0DBS2503264 DBS 6M LONG
0DNP0CF1100 CALIBRATION FRAME Measuring range 50mm 0DBS2503294 DBS 9M LONG
Base length adjustable at 200, 300 or 500mm
Digital gauge 5 digits LCD, 6mm height Loading capacity 250 KN
Resolution 0.01 mm
Gauge range 100 mm Anchoring points 4
Repeatability better than ±0.02mm
Gauge resolution 0.01 mm Overall outer diameter 40 mm
Repeatabilty ± 0.1 mm Drilling diameter 50 mm
Tape width 13 mm Accessories Materials:
Tape scale division centimetre punched every 25mm 0DF25PIN200 UNIAXIAL CRACKMETER - Rods iron
Body diameter 60 mm 0DF20TKIT00 3-D CRACKMETER ASSEMBLY - Central anulus brass
Overall length 870 mm - Head Stainless steel
MECHANICAL JOINTMETERS
REFERENCE BOLTS 0D3101D3000 UNIAXIAL CRACKMETER MANUAL MEASURING EQUIPMENT
A wide range of measuring bolts are available that can 0D3103D3000 3-D CRACKMETER ASSEMBLY (Product code 0DIG10KDBS0)
be grouted, welded or anchored to the structure. Mechanical range 0-30mm (±15) in all directions In order to take manual measurements, it is also
0DN0CH20000 200mm groutable 3/8” stud bolt Base lengths 500 mm (uniaxial) needed to install onto the instrument head the
0DN0CH50000 500mm groutable 3/8” stud bolt or 200 mm (3-D triaxial) mechanical measuring kit 0DBS01MEC00.
0DN0CHE1000 1000mm groutable 3/8” stud bolt Range 0 – 10 mm
0DN0CH05000 weldable 3/8” stud bolt DIAL GAUGE KIT Resolution 0.01 mm
0DN0CH20E00 200mm groutable eyebolt (Product code 0DIG30KIT00)
0DN0CH05E00 weldable eyebolt Measuring range 0-30mm (±15) in all directions 4-FOLD VIBRATING WIRE MEASURING HEAD
0DN0TS10E00 wall eyebolt Resolution 0.01 mm (Product code 0DBS04DTE00)
Accuracy 0.05 mm Displacement transducer 4 nos. vibrating wire
REMOVABLE TARGETS Range +/- 5mm
(Product code 0GCTR005000) TELL-TALE CRACK MONITOR Resolution 0.01 mm
Reflective targets allow (Product code 0D300LINE00) Accuracy < 0.5% FS
automatic convergence Operating temperature -20°C +80°C
monitoring by topographic total Signal output frequency
station. Dimension Length 270mm, OD 54mm
Designed to fit the 3/8” stud
convergence bolts by its own
adaptor.
TT-1 type 2-D biaxial
0GCTR38ADS0 3/8”G stainless steel stud adaptor
Mechanical range ±25 mm in both directions
0GCTR38ADP0 3/8”G plastic stud adaptor
Resolution 0.01 mm
Accuracy 0.05 mm

EXTENSOMETERS & JOINTMETERS 31 www.sisgeo.com


BOREHOLE ROD EXTENSOMETERS

ELECTRIC & VW DISPLACEMENT TRANSDUCERS

EMBANKMENT EXTENSOMETERS
EXTENSOMETERS & JOINTMETERS

San Jose’ Mine - Chile


Borehole Rod Displacement Embankment
Extensometers Transducers Extensometers

Rod extensometers are installed in boreholes in order Borehole rod extensometers could be simply read with Embankment (soil) extensometers are used to measure
to monitor displacements at various depths using rods mechanical depth gauge. soil strains in large earth structures. During the
of different materials and lengths. The mechanical system is easily converted to provide construction stage, the embankment extensometers
A pre-set length of measuring rod is inserted into a an electrical output for remote monitoring and data are usually incorporated in the filling material.
nylon tube to avoid soil friction and its tip is fixed to a acquisition. An electrical or vibrating wire linear The system consists of a number of anchor plates
steel groutable anchor. Preassembled fibre glass rods displacement transducer is fitted to each extensometer connected by extension rods to the measuring
are coiled when manufactured and shipped ready for rod on the instrument’s head. elements.
installation. The range of the displacement transducer is selected to The measuring element is a telescopic tube equipped
Stainless steel and invar rods are supplied in bars of 2 match the expected rod displacement. The transducer with a vibrating wire displacement transducer to
meters length; they need to be mounted on-site. can be adjusted on the extensometer head to trim the monitor the change in distance between two anchor
The complete rod extensometer assembly is grouted zero position. plates.
through a dedicated tube, fixing the anchors to the rock An electric cable connects the displacement A number of elements may be chained together by
or soil but, at the same time, allowing free movement transducers to the measuring box for manual readings means of 1, 2 or 3 m extension rods. Vibrating wire
of each rod within its sleeve. with portable readout, or to the ADK-100 automatic displacement transducers are available in different
data acquisition system. ranges for measuring up to 150 mm of displacement.

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS

0D222AC00A0 s/steel or invar rods, DTE < 100 mm DTE DISPLACEMENT TRANSDUCERS System Components
0D222AC00B0 s/steel or invar rods, DTE > 100 mm DTE transducers are available either with linear 0D2320BM100 EXTENSION ROD, 1 M
0D222FG00A0 fibre glass rods, DTE < 100 mm potentiometer or vibrating wire transducer. 0D2320BM200 EXTENSION ROD, 2 M
0D222FG00B0 fibre glass rods, DTE > 100 mm 0D2320BM300 EXTENSION ROD, 3 M
Linear Potentiometers 0D111PV5500 PVC CORRUGATE ANTIFRICTION SLEEVE
Number of bases 1 (single), from 2 to 7 (multiple)
Measuring range 25, 50, 100, 150, 200mm 0D232AN5000 ANCHOR PLATE, DIAM 500 MM
Multiple head top tube OD 120 mm
Resolution 0.01 mm (depending of readout) 0D232AN5500 ANCHOR PLATE, 500x500 MM
Extensometer rods FG fibre glass continuous
Accuracy <0.3% FS
AC stainless steel, 2 m sections
Signal output 4-20 mA (current loop) MEASURING ELEMENTS
IN invar, 2 m sections
Power supply 12-24V DC 0D232T050VW 50 mm (±25) range
Protective sleeve nylon 11 (rilsan), OD 12 mm
Operating temperature -20°C +60°C 0D232T100VW 100 mm (±50) range
Groutable anchor FG: rebar 16mm OD, 400 mm long
Overall diameter 16 mm 0D232T150VW 150 mm (±75) range
AC/IN: rebar 22m OD, 400 mm long
Environmental IP68 (watertight up to 100 kPa)
Type of sensor vibrating wire with built-in thermistor
System Components Vibrating Wire Transducers Measuring range 50, 100, 150mm
0D221BMFG00 FIBRE GLASS ROD, 0D 7mm Resolution 0.01 mm (depending of readout)
Measuring range 25, 50, 100, 150 mm
0D221BMAC00 STAINLESS STEEL ROD, OD 8mm Accuracy <0.5% FS
Resolution 0.01 mm (depending of readout)
0D221BMIN00 INVAR ROD, OD 8 mm Signal output frequency
Accuracy < 0.5% FS
0D222TOP200 PROTECTIVE CAP, DTE: 10, 25, 50mm Operating temperature -20°C +80°C
Signal output frequency
0D222TOP320 PROTECTIVE CAP, DTE: 100,150,200mm Material stainless steel
Operating temperature -20°C +80°C
0D222KTOP01 SINGLE BASE CAP KIT
Overall diameter 16 mm
0D222K7AC00 INSTALLATION KIT FOR AC/IN RODS
Environmental IP68 (watertight up to 100 kPa)
0D222K6FG00 INSTALLATION KIT FOR FG RODS

DIGITAL GAUGE
(Product code 0DIGD020000)
Measuring range from 0 to 200mm
Resolution 0.01 mm

EXTENSOMETERS & JOINTMETERS 33 www.sisgeo.com


CRACKMETERS & JOINTMETERS

WIRE CRACKMETERS AND DEFORMETERS

FIXED EXTENSOMETERS
EXTENSOMETERS & JOINTMETERS

Carrara Marble Quarry - Italy


Crackmeters Wire Crackmeter Fixed
And Jointmeters And Deformeter Extensometers

Crackmeters and jointmeters are utilized to monitor Wire crackmeter is designed to monitor changes in Fixed extensometer is usually defined as a device
movements across surface cracks and joints in distance between two anchor points located at up to placed in embankment fill or inside a borehole for
concrete structures or rock. The instrument assembly 30m. monitoring settlement or heave between two points,
includes a sensor housing and a target. Both parts are Typical applications include measurements of large without using a removable probe.
equipped with screw anchors. displacement associated with landslides, monitoring of The settlement platform or the tell- tale extensometer
Typically, the anchors are bolted on the opposite sides rock- masses, masonry cracks and surveying of earth can be used, based on a string of settlement rods.
of the joint (crack). The displacement transducer faults. The wire crackmeter consists of a stainless steel These are, respectively, connected to a plate buried at
housed in the sensor body is positioned across the transducer box and target assembly made by an the embankment foundation level or to a datum point
joint/crack which enables measurement of the changes eyebolt expansion anchor. grouted inside the borehole in firm soil.
in the distance between the anchors. The electrical deformeter is used to monitor the Optical levelling of the top of the riser rod provides
CRID is an integrated system for fissure monitoring of displacement between two opposite surfaces and precise monitoring. Electrical transducers can be used
building and monuments, which reduces the visual convergence in underground openings and tunnels. for automatic remote readings even for inaccessible
impact. CRID includes four miniature fissure meters The displacement transducer is housed in a stainless locations.
(sensors) connected by signal cable to a compact, steel body mounted on a fixing plate for wall/floor
battery-powered datalogger for automatic data installation. A Kevlar rope forms the connection
acquisition. between the transducer and the target.

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS

Linear potentiometer transducers WIRE CRACKMETER SETTLEMENT PLATFORM


Full scales 10, 25, 50, 100, 150mm (Product code 0D241A20000) The primary advantage of the settlement platform is its
Resolution 0.01 mm (dependent of readout) Mechanical range 2000 mm simplicity. The settlement platform consists of a
Total accuracy ± 0.3% FS Electrical range 240 mm galvanized square plate to which a riser settlement rod
including linearity and hysteresis Sensitivity 0.03 mm is attached. Anti-friction corrugate pipe is placed
Signal output 4-20 mA (current loop) Accuracy ±1 mm (depends mainly from the around the riser rod. Optical levelling measurements,
Power supply 12-24V DC thermal effects on the wire) on the survey point mounted on the top cap, provides
Operating temperature -20°C +60°C Repeatability ±0.03 mm records of plate elevation.
Sensor diameter 16 mm Signal output 4-20 mA (current loop) 0D100A20000 2M SECTION RISER ROD
Anchor distance 500 mm Operating temperature -20°C +60°C 0D111PV5500 CORRUGATE PIPE, OD 55mm
Environmental IP68 (watertight up to 100 kPa) Wire diameter 2 mm, stainless steel 0D100B05000 SQUARE PLATE 500x500mm
Material stainless steel Max. wire tension 8 Kg 0D100T15000 TOP CAP AND SURVEY POINT
Base (wire) length up to 30 meter
Vibrating wire transducers distance between transducer and target TELL-TALE EXTENSOMETER
Full scales 10, 25, 50, 100, 150mm Transducer housing 300x200x185 mm The tell-tale extensometer is a single-point
Resolution 0.01 mm (dependent of readout) Target assembly eyebolt expansion anchor extensometer which is, typically, used for precise
Total accuracy <0.5% FS monitoring of ground surface settlement or heave. It
including linearity and hysteresis WIRE DEFORMETER consists of a stainless steel bottom anchor to which a
Signal output frequency (Product code 0D313F00000) string of riser measuring rods is attached. Anti-friction
Operating temperature -20°C +80°C corrugate pipe is placed around the riser rods. Optical
Sensor diameter 16 mm levelling measurements of the top head of the riser rod
Anchor distance max 500 mm provides a measure of ground settlement. Sliding rings
Environmental IP68 (watertight up to 100 kPa) are located at both ends in order to prevent down drag
Material stainless steel forces on the rod.
0D100A20000 2M SECTION RISER ROD
Accessories for 2-D and 3-D monitoring Type of sensor linear potentiometer or vibrating wire 0D111PV5500 CORRUGATE PIPE, OD 55mm
0D31Y1DTE00 Y-AXIS FIXING PLATE Signal output 4-20 mA, frequency 0D100TT6000 BOTTOM ANCHOR
0D31Z1DTE00 Z-AXIS PAIR OF FIXING PLATE Measuring range 25 mm (±12.5), 50 mm (±25) 0D100TT0100 TOP CAP AND SURVEY POINT
Resolution 0.01 mm (depending on readout) 0D100TTEL10 DTM MEASURING HEAD
Total accuracy <0.3%FS (4-20mA)
<0.5%FS (vibrating wire) DTM ELECTRICAL TRANSDUCERS
Operating temperature -20°C +60°C (Product code 0DTM0000000)
Wire Kevlar rope DTM electrical transducers can be mounted on either
Base (wire) length up to 10 meter settlement platforms or the tell-tale extensometers.
Sensor housing 16mm diam. Range 250mm, 500mm, 1000mm
Total accuracy 0.25% F.S.
Output signal 4-20 mA

EXTENSOMETERS & JOINTMETERS 35 www.sisgeo.com


DIRECT AND INVERTED PENDULUMS

REMOVABLE COORDINOMETER

TEL-310S TELECOORDINOMETERS
PENDULUMS & READOUT

Ermenek Dam - Turkey


Direct And Inverted Removable Tel-310S
Pendulums Coordinometer Telecoordinometer

Hanging pendulums are designed to monitor horizontal Sisgeo pendulum optical readout (coordinometer) is a TEL-310S telependulum is an optical device designed
movements. They are very commonly utilized in reliable and simple equipment for manual readings of for automatic measurements of the coordinates of the
concrete dams to measure change of verticality of the direct and inverted pendulums. pendulum plumb lines.
structure. The coordinates of the pendulum steel wire are TEL-310S permits high accuracy continuous
The direct pendulum is a gravity-referenced measured by means of a pair of photocells mounted on monitoring. It consists of three separate units:
instrument. It consists of a steel wire anchored at a a high accuracy sliding unit. It permits to calculate the - SUS optical unit, equipped with stepper motor
fixed point and a damping tank containing damping horizontal movements of the wire both in the assembly, spirit level and waterproof protective cover;
fluid. upstream-downstream directions and left bank-right -CUS control unit, with communication interfaces and
The inverted pendulum provides a fixed datum from bank directions. on-board web server;
which structural movements can be measured. It It can be utilized either for in-place installation or - PWS power supply unit with selectable voltage
utilizes the identical wire anchored in borehole beneath removable measurements in different locations. input.
the structure, with a floating unit fixed to its upper end. Pendulum reading locations are equipped with a TEL-310S is also supplied with adjustable optical
The floating unit is free to move in a fluid tank, keeping support plates. The plates have fitting guides for sensor support, calibration checking frame and
the wire vertically suspended. accurate and repeatable positioning of the pendulum mounting kit.
Pendulums are often installed in shafts in the concrete optical readout. All TEL-310S units are waterproof so hard wet
of the dam starting with an inverted pendulum installations and temporary submersion do not demage
anchored in foundation to obtain a complete profile of instruments.
the change in the verticality of the dam.

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS

DIRECT PENDULUM PENDULUM OPTICAL READOUT TELEPENDULUM TEL-310S


(Product code 0S911002500) (OPTICAL COORDINOMETER) (TELE-COORDINOMETER)
Direct pendulum assembly includes: (Product code 0S9RTB15000) (Product code 0TEL3103GS0)
- stainless steel cylindrical fluid tank with cover Measurement area X-axis: 0-150mm (±50mm) Measurement area X-axis: 0-150 mm
- wire tensioning weight and damping unit Y-axis: 0-150mm (±50mm) (Nominal) Y-axis: 0-60 mm
- upper wire anchor system with rail and sliding block Gauge resolution 0.01 mm Measurement area X-axis: 0-145 mm
- turnbuckle for trimming the damping unit position Gauge accuracy <0.1 mm (Real) Y-axis: 0-60 mm
Gauge protection IP67 Resolution 0.005 mm
Tank dimensions 415mm diam, 476mm high
Temp. operating range -20°C +60°C Repeatability+Accuracy X-axis: ±0.007 mm
Material stainless steel
Material aluminium (Nominal) Y-axis: ±0.012 mm
Damping fluid (mineral oil) SAE 50-90 (not supplied)
Dimensions 340x340x115mm Total accuracy X-axis: ±0.010 mA
Weight 3.5 kg (repeatability+accuracy+hysteresis) Y-axis: ±0.015 mA
INVERTED PENDULUM Power supply 110/220V AC, 50-60Hz
(Product code 0S912006000)
Accessories Communication
Inverted pendulum assembly includes:
0S9RTPLT100 COORDINOMETER SUPPORT PLATE - Local readings USB 2.0, Ethernet, Bluetooth (option)
- stainless steel anular damping chamber with cover
0S9RTFR1000 COORDINOMETER CALIBRATION FRAME - Remote monitoring RS485, 4-20mA (to ADK-100)
- stainless steel floating unit
Memory 2 GB
- adjustable tie bar with 100mm vertical stroke
Temp. operating range -10°C +60°C
- external tube for liquid level survey
Humidity (UHR) 100%
- steel ballast for borehole wire anchoring
Overall dimensions and weight
Tank dimensions 615mm diam, 495mm high - SUS optical unit 630x280x165 mm, 11.2 kg
Floating unit allows ±72mm movement in - CUS control unit 330x345x111 mm, 4.8 kg
any direction - PWR power supply unit 330x250x111 mm, 5.8 kg
Groutable anchor diameter 75mm, adjustable from Detectable wire minimum 1.5mm diam.
80mm to 160mm by Protection IP68 until 50 kPa
centralized pins
Material stainless steel Accessories
Damping fluid (mineral oil) SAE 50-90 (not supplied) 0TEL310ANS0 ADJ. OPTICAL SENSOR SUPPORT
0TEL310CAL0 CALIBRATION AND MOUNTING KIT
PENDULUM WIRE 0TEL310XBT0 BLUETOOTH MODULE
(Product code 0WRAC200000) 0TEL310XC53 IP68 CABLE FOR RS485 NETWORK
Material stainless steel 0TEL310X485 RS485 TO USB INTERFACE
Diameter 2mm 0TEL310XC83 IP68 CABLE FOR 4-20MA NETWORK

PENDULUMS & READOUT 37 www.sisgeo.com


ARC WELDABLE AND EMBEDMENT STRAIN GAUGES

SPOT WELDABLE STRAIN GAUGES

VIBRATING WIRE REBAR AND SHOTCRETE STRAIN GAUGES


STRAIN GAUGES & THERMOMETERS

Ferrari Factory New Building - Italy


Arc Weldable Spot Weldable Vibrating Wire Rebar
And Embedment Strain Gauges And Shotcrete
Strain Gauges Strain Gauges

Vibrating wire strain-gauges are used to monitor strain Spot weldable strain-gauges are designed to measure Rebar strain-meters are designed for direct embedment
in steel or in reinforced concrete and mass concrete strains in steel structures. They can be installed quickly in concrete. They are used for measuring strain in
structures. and easily on the field, requiring the use of portable foundations, concrete walls, piles and bridge abutments.
Arc-weldable vibrating wire strain-gauges are spot welder only. Installation can be also made by Rebar incorporates the vibrating wire strain gauge
designed for arc welding to steel structures such as epoxy resin by bonding the gauge onto the structure. element with plucking coil. A thermistor is included in
tunnel linings, piles and bridges. The gauge is supplied The spot weldable strain gauge has a removable coil each strain meter as a standard feature and permits
with end mounting blocks. unit which also incorporates the built-in thermistor for measurement of temperature at the rebar strain meter
Embedment vibrating wire strain-gauges are directly temperature measures. If the gauge location is not location.
embedded in concrete for strain measurements of accessible the coil unit is attached permanently on the Vibrating wire rebar strain meters are available in
piles, foundations, dams, tunnels linings, etc. gauge. different units in order to match the sizes of the concrete
Vibrating wire strain-gauges are particularly durable The spot weldable strain gauge is a small size gauge reinforcing bars. They are intended to be welded at their
and thermally-aged to minimize long-term drift and with 50.4mm active gauge length. The wire tension can ends into the rebar system and so the rebar size is
changes in calibration. Thermistor is incorporated in be set to place the range mostly in compression or chosen to match the existing reinforcing bar.
the coil housing. The standard gauge length is 150mm mostly in tension by means of leaf springs.
with a nominal range of 3000 με.

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS

0VK4000VS00 ARC-WELDABLE GAUGE VW SPOT WELDABLE STRAIN GAUGE 0VKBAR01800 VW REBAR 18 MM NOMINAL OD
0VK4200VC00 EMBEDMENT GAUGE (Product code 0VK4100VS00) 0VKBAR02200 VW REBAR 22 MM NOMINAL OD
0VK4200VN00 NO-STRESS EMBEDMENT GAUGE Range 3000 με (nominal) 0VKBAR02600 VW REBAR 26 MM NOMINAL OD
Sensitivity 1.0 με 0VKBAR03000 VW REBAR 30 MM NOMINAL OD
Active gauge length 150mm
Resolution 40 με
Measuring range 3000 με (nominal) Range 2500 με (nominal)
Thermal coeff. of expansion 11.3x10-6/°C
Sensitivity 1 με Sensitivity 1.0 με
Coil resistance ≤150 Ω
Total accuracy < 2% FS Accuracy < 2% FS
Temperature range -20°C +80°C
Stability 0.1% FS/ year Stability 0.1% FS/yr
Active gauge length 50.4 mm
Typical frequency 800 - 1200 Hz Nominal gauge factor 3.38 x 10-4 με /f2
Overall length 63.5 mm nominal
Coil resistance ≤150 Ω Typical frequency 800 - 2500 Hz
Temp. operating range -20°C +60°C Coil Resistance ≤150 Ω
Accessories
Temperature range -20°C +70°C
0VK410PSW00 Portable spot welder
Accessories 0VK410KIT00 Leaf spring installation kit
Bar length 400 mm
0VK42VC3D00 Mounting block for rosette 3-D
assembling (X-Y-Z directions) SHOTCRETE STRAIN GAUGES
0VK400JIG00 Mounting jig for weldable (Product code 0VK4000SM00)
strain-gauges Shotcrete vibrating wire strain gauges are designed for
0VK400MB200 Pair of arc-weldable surface tunnel monitoring where is used the shotcrete method
mounting blocks for concrete lining; in fact this method request an
higher working range than common vibrating wire
strain gauges.
Range 10000 με (nominal)
Sensitivity 1.0 με
Resolution 40 με
Thermal coeff. of expansion 11.3x10-6/°C
Temperature range -20°C +80°C
Gauge length 200 mm

STRAIN GAUGES & THERMOMETERS 39 www.sisgeo.com


RESISTIVE STRAIN GAUGES

EMBEDMENT THERMOMETERS

PORTABLE THERMAL PROBES


STRAIN GAUGES & THERMOMETERS

De Gasperi Bridge - Italy


Resistive Embedment Portable
Strain Gauges Thermometers Thermal Probes

The resistive strain-gauge incorporates four high Temperature is a very important parameter in order to The portable thermal probes are designed for both water
output electrical strain gauges in full bridge evaluate the influence of thermal effects on the temperature and water level measurements in wells,
configuration bonded to a steel bar. This arrangement measurements and the structure which is being boreholes and standpipe piezometers.
allows compensation for both temperature and bending monitored. It consists of a dipping probe mounted on a millimetre
effects. Sisgeo uses two types of practical devices to monitor tape. Tape is rolled up on a rugged portable reel which
Resistive strain-gauges offer a valid alternative to the temperature: thermistors and RTDs (Resistance contains electronic and battery pack.
vibrating wire type when continuous measurements Thermal Detectors). The dipping probe mounts a microchip-based integrated
are required. RTDs provide highest accuracy in comparison with circuit (IC) for temperature measures that produces an
They have a standard length of 400 mm and are thermistors and thermocouples. The RTD is precision output proportional to absolute temperature.
available in two models: for embedment in concrete or trimmed at the manufacturing stage using a platinum Temperature values are directly displayed in °C on a 3.5
welded onto steel surfaces. device of 100 ohms at 0°C which guarantees long-term LCD mounted on the face-plate of the reel where are also
Measurements are carried out by Torricelli readout or stability . located the front panel controls.
Leonardo portable datalogger. Automatic monitoring Both RTDs and thermistors are housed in a shock
can be obtained by ADK-100 data acquisition system. resistant stainless steel body for application in air,
water and for direct embedment in concrete.

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS

0L3400VS000 STRAIN-GAUGE BAR, mV/V O/P RTD THERMOMETER Temperature transducer IC 590
0L3400VSC00 STRAIN-GAUGE BAR, V O/P (Product code 0T111PT1000) Cable lengths 30, 50, 100, 150m
0L3400AS000 STRAIN-GAUGE BAR,4-20 mA O/P Type of sensor PT100 Temperature range -50°C +150°C
platinum resistance 100 Ω at 0°C Resolution 0.1°C
Bar section 8x8 mm
Measuring range -50°C +150°C Accuracy ± 0.5°C
Bar length 400 mm
Resolution 0.1°C Probe diameter 16 mm
Measuring range ±1500 με (nominal)
Accuracy 0.2°C Probe length 250 mm
Sensitivity 0.0015 mV/με
Diameter 22 mm Digital display 3.5 LCD
Total accuracy < 1% FS
Length 100mm Batteries 2 x 9V DC disposal
Zero temp. drift <0.05% FS /°C
Material stainless steel Operating time about 20 hours
Signal output 2 mV/ at FS
4-20 mA (current loop)
THERMISTOR SPARE SET FOR C112T
Temp. operating range -20°C +70°C
(Product code 0T3800GKA00) (Product code 0C112TKITR0)
Type of sensor NTC thermistor (YSI 44005) Spare set for portable water-thermal probe includes probe,
CABLES AND ACCESSORIES Measuring range -50°C +150°C weights, epoxy resin and consumable.
0WE10600000 Electric cable 6 wires (24 AWG) for
Resolution 0.1°C
strain gauges mV/V or V output
Accuracy 0.5°C
0WE102KEO00 Electric cable 2 wires (20 AWG) for
Diameter 12 mm
strain gauges 4-20mA output
Length 55 mm
0L3400MB200 Pair of welding blocks for
Material stainless steel
resistance strain gauges

CRD-400 TEMPERATURE INDICATOR


(Product code 0CRD4000000)
Temperature readings on RTD thermometers and
thermistors can be taken using the small CRD-400
readout: it can display measure directly in °C through
an automatic conversion.
Type of measure °C
Display graphic color TFT, 240x320 pixel
Accuracy 0.01% FS
Internal battery Ni-MH rechargeable 4.8 V–2.7 Ah
Operating temperature -20°C +60°C
Protection IP67

STRAIN GAUGES & THERMOMETERS 41 www.sisgeo.com


READOUT UNITS

PORTABLE DATALOGGERS

FIELD MINILOGGERS
READOUTS, DATALOGGERS & ACCESSORIES

Orenburg City Business Center - Russia


Readout Units Portable Dataloggers Field Miniloggers

CRD-400 is the new hand-held universal readout Galileo, Leonardo and New Leonardo are durable, water- ADR Minilogger is a family of compact, multi-channel
designed to take readings of any kind of Sisgeo’s resistant and easy-to-use portable dataloggers. They are dataloggers designed for use with vibrating wire and 4-
instrument. Main features are the color graphic disply equipped with high performance microprocessor, Ni-MH 20mA sensors. PC communication is done through its
sunlight reliable, the Ni-MH rechargeable battery and batteries and color graphic display (sunlight reliable). on-board USB or RS485 interface.
the splash-proof casing. CRD-400 permits to display New Leonardo datalogger is capable of reading all types of Readings can be stored in a high capacity memory
readings in both electrical and and engineering units; Sisgeo’s sensors; Galileo is designed for use with vibrating wire which has a full capacity of 64.000 data (VW
moreover battery level is always displayed on screen. instruments. Both dataloggers utilize Fourier transform to Minilogger) and 43.000 data (Mini Datalogger),
VOLTA is a vibrating wire readout that utilizes Fourier filter the harmonic frequencies in order to avoid erratic allowing the possibility for these units to be used as
transform to filter the harmonic frequencies in order to measurements. stand-alone dataloggers.
avoid erratic measurements. Readings are stored in a 2GB memory and the saved data can Miniloggers are supplied with replaceable batteries
TORRICELLI is a dual channel readout unit configurable be easily transmitted to a host PC through USB cable. Portable (VW model) or 220V (4-20mA model); user could also
at factory for any type of sensor. Quick-connect dataloggers could be equipped with bluetooth built-in choose a 20W solar panel kit.
terminals allow direct connection of sensor signal module in order to sent data to the office in real time Miniloggers are managed by a specific software.
cables and battery chargers. through smart phone. Through this software, the user may set starting time
All models of Sisgeo portable readout units are SMART MANAGER SUITE software permit to manage the and acquisition time intervals, download and view data
supplied with shoulder bag, battery charger and jumper dataloggers directly from PC or notebook; moreover SW (both in tabular and graphical form), perform direct
cables. and FW update will be done automatically. sensor readings and calibrate the unit.

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS

CRD-400 HAND HELD READOUT NEW LEONARDO DATALOGGER MINI DATALOGGER


Number of channels one (1) Number of channels two (2) Sensor compatibility 4-20 mA (current loop)
A/D converter 24 bit with autocalibration A/D converter 2 x 24 bit with autocalibration Number of channels four (4)
Display graphic color TFT, LED backlight Display graphic color TFT, LED backlight Scanner type digital
240x320 pixel, sunlight reliable 320x240 pixel, sunlight reliable Resolution 5 μA
Type of measurement mA, mV, mV/V, V, °C Type of measurement mA, mV, mV/V, V, Ω (PT100/NTC) Numbers of readings 43.000 (64 k bytes)
vibrating wire vibrating wire Acquisition time interval programmable from 1min to 18hr
Resolution 1 μA at F.S. 20 mA Storage memory 2 GB Communication USB 2.0 mini AA cable
1 μV at F.S. 20 mV Resolution 1 μA at F.S. 20 mA Logger battery 3V DC button battery
0.001mV/V at F.S. 10 mV/V 1 μV at F.S. 20 mV Instrum. power supply 12V 4.5Ah rechargeable battery
0.1 Hz, 0.1 °C 10 μV at F.S. ±400mV Environmental -20°C +60°C, IP65 case
Accuracy 0.01% FS 0.001mV/V at F.S. 10 mV/V
Battery 4.8 V, 2.7 Ah Ni-MH rechargeable 0.1 Hz, 0.1 °C Accessories
Operating time 8 hours (continuosly) Battery 12V 4,5 Ah rechargeable Ni-MH 0AHOBO220V0 EXT. POWER SUPPLY BOX, IP67
Environmental -20°C +60°C, IP67 Operating time 8 hours (continuosly) 0AHOBO12SOL SOLAR PANEL PACK - 20W, 12Ah
Dimensions and weight 98 x 200 x 50 mm, 0.9 Kg Dimensions (LxWxH) 200 x 280 x 65 mm 0SWBHW10000 MANAGER SOFTWARE
Weight 2 kg
TORRICELLI READOUT Environmental -20°C +60°C, IP67 VW MINILOGGER
Number of channels two (2) COMM port USB 2.0 (pen drive style) Sensor compatibility Vibrating Wire, NTC thermistors
Displayed unit mA, mV, mV/V, V, Number of channels six (6)VW or (3)VW+(3)T
±20.000 sin α, °C GALILEO DATALOGGER with different configuration
Display alpha-numeric backlight LCD Type of measurement vibrating wire, NTC thermistor Scanner Type electromechanical relays
240 x 128 pixel Number of channels two (2) Resolution 0.1 Hz, 0.1°C
Battery 12V 4,5 Ah rechargeble Ni-MH Display graphic color TFT, LED backlight Numbers of readings > 10.880 per channel
Environmental -10°C +50°C, IP67 320x240 pixel, sunlight reliable Acquisition time interval programmable from 1min to 48hr
Storage memory 2 GB COMM port RS 485 (19200 Baud))
VOLTA VIBRATING WIRE READOUT Resolution 0.1 Hz, 0.1 °C Battery 9V DC (6x1.5V D type)
Number of channels two (2) Battery 12V 4,5 Ah rechargeable Ni-MH Environmental -20°C +60°C, IP67 case
Displayed unit frequency2x10-3, period, με, °C Operating time 8 hours (continuosly)
Display alpha-numeric backlight LCD Dimensions (LxWxH) 200 x 280 x 65 mm Accessories
240 x 128 pixel Weight 2 kg 0ECAV485I00 RS485I INTELLIGENT CABLE
Battery 12V 4,5 Ah rechargeble Ni-MH Environmental -20°C +60°C, IP67 0AX20W040AH SOLAR PANEL PACK-20W, 40Ah
Environmental -10°C +50°C, IP67 COMM port USB 2.0 (pen drive style) 0SWDL300000 DL MASTER SOFTWARE

READOUTS, DATALOGGERS & ACCESSORIES 43 www.sisgeo.com


ADK-100 DATA ACQUISITION SYSTEM

ADK-100 COMPONENTS

SOFTWARE AND WEB SERVICES


READOUTS, DATALOGGERS & ACCESSORIES

Modena Bridge – Italy


Adk-100 Adk-100 Software
Data Acquisition System Components and WEB services

Sisgeo ADK-100 is a powerful and versatile multi- A complete data acquisition system requires additional ML Multilogger Software is a 32 bit application
function datalogger built around the Campbell components such as multiplexer boards, designed to manage data acquired from monitoring
Scientific CR1000 measurement and control module. A communication modules, safe power supply and instrumentation, whether connected directly to the PC
multi-tasking operating system allows simultaneous enclosure. The ADK-100 datalogger offers a variety of or connected to remote accessible PC via
communication and measurement functions. components to meet all client’s requirements. communication peripherals.
Multiplexers with built-in over voltage protections Communication is made by direct USB cable The channel configuration form configures instruments
provide additional inputs up to 192 analogue or 96 connection or through any kind of remote interface connected via ADK-100 multiplexers and extended
differential channels. (GSM or phone modem, fibre optic, RS485 digital cable, parameters referring to special processing that is done
ADK-100 datalogger is designed for field use, available ethernet network, etc…) such as summing measurements from multiple
in different versions. All versions are housed in water- An extensive range of sensors can be read and stored channels. Each channel could be configured with linear
resistant IP65 stainless steel enclosures. in any user-selected engineering unit. Each type of or polynomial coefficients in order to return engineering
ADK-100 is ideally suited, not only for data logging, but sensor can be powered directly from the ADK-100 values.
for alarm notification of any sensor parameter when a during measurement by means of specific ML Software function is not limited to programming the
preset threshold value is exceeded. Control actions can components. ADK-100 datalogger, download, monitoring, alarm
be managed through Multilogger Software. ADK-100 power supply is assured by 220V voltage or management and data collection are also supported.
through solar panel package supplied with battery and
mounting pole.

TECHNICAL SPECIFICATIONS COMPONENTS AND INTERFACES WEB SERVICES

ADK-100 CAB VERSIONS 0ADK16MUX00 MULTIPLEXER BOX 8/16 CH WEB MONITORING SYSTEM
0ADK100BOX0 CR-1000 MODULE, IP65 CABINET IP65 enclosure 300x300x180mm WMS runs inside a dedicated WEB portal and allows
dim. 600x400x150mm 0ADK32MUX00 MULTIPLEXER BOX 16/32 CH authenticated users to access customized pages where
0ADK100CAB3 CR-1000 MODULE, IP65 CABINET IP65 enclosure 300x300x180mm many advanced services can be displayed such as raw
enables configuration of up to 3 MUX 0ADK32MU200 MULTIPLEXER BOX 2x8/16 CH data automated conversion, manual and automatic
boards, dim. 800x600x250mm IP65 enclosure 400x300x180mm data validation, real-time data analysis and graphical
0ADK10CAB60 CR-1000 MODULE, IP65 CABINET 0ADK64MU200 MULTIPLEXER BOX 2x16/32 CH display, SMS/e-mail advanced alarms setup, synoptic
enables configuration of up to 6 MUX IP65 enclosure 400x300x180mm chart with instruments status alarm, etc...
boards, dim. 800x600x250mm 0ADKBRELEBS ADDITIONAL RELAYS INPUT Inside WMS could also run on FIELDSTAT, a software
0ADK100C160 CR-1000 MODULE, IP65 CABINET 0ADKWE65000 3M CABLE WITH CONNECTORS designed, built and developed by Sisgeo and Field, in
with built-in 8/16 MUX board to connect MUX boxes to ADK100BOX collaboration with the University of Bergamo for the
0ADK100C320 CR-1000 MODULE, IP65 CABINET 0ADKB0816R0 MULTIPLEXER BOARD 8/16 CH statistics analysis of historical data recorded by the
with built-in 16/32 MUX board 0ADKB1632R0 MULTIPLEXER BOARD 16/32 CH monitoring systems. Fieldstat allows to determine and
0ADKEXKV100 OVERVOLTAGE PROTECTION KIT correct the correlations that may influence data (i.e.
CR-1000 module technical specifications includes either bipolar and tripolar temperature).
Processor Renesas H8S 2322 plasma surge arrestors for each
Memory 2MB flash, 4MB SRAM for data multiplexer entry
Analog inputs 6 differential expandible by 0AXBCO22000 IP67 POWER SUPPLY
multiplexer (MUX) up to 192 0AX30W060AH POWER SUPPLY PACKAGE
Digital I/O ports 8 ports software selectable as binary 30W solar panel and 60Ah battery
inputs or control outputs. 0AX60W100AH POWER SUPPLY PACKAGE
Range 60W solar panel and 100Ah battery
- analog from ±2.5 mV to ±5.0 V 0AX0PALO280 SUPPORTING POLE, 3.0 M
- frequency DC to 200 kHz
Resolution INTERFACES Raw data
- analog from 0.33 ÌV to 1330 ÌV 0ADKMD48500 MD-485 MULTIDROP MODULE
- frequency ±60x10-6sec/ no. cycles measured 0AXETH100NL NL100 NETWORK LINK INTERFACE
Accuracy 0.06% of reading+offset (0 to 40°C) 0AXFOD00000 FIBER OPTIC INTERFACE
COMM port CS I/O port for Campbell interfaces 0AXGSM0M02 EXTERNAL GSM WITH ANTENNA
RS232 port for other interfaces 0AXGSM0D200 BUILT-IN CELLULAR PHONE PACK
Battery 12V 7.2 Ah, rechargeable 0AXGPRSM02 QUAD BAND EXTERNAL GPRS MODULE
Power supply 85-264V AC-50/60 Hz, IP67 0AXGPRS0D0 QUAD BAND BUILT-IN GPRS MODULE
Temp. operating range -25°C +50°C 0AXCOM210E0 TELEPHONE MODEM
0AXBTCL1E05 BLUETOOTH CLASSE I INTERFACE

Data after Fieldstat elaboration

READOUTS, DATALOGGERS & ACCESSORIES 45 www.sisgeo.com


JUNCTION AND TERMINAL BOXES

READOUT ACCESSORIES AND SPARE PARTS

CABLES
READOUTS, DATALOGGERS & ACCESSORIES

MART Museum - Italy


Junction And Readout Accessories Cables
Terminal Boxes And Spare Parts

Different models of waterproof junction boxes are In order to simplify the mounting, installation and reading Sisgeo cables are designed for a variety of geotechnical
available for single or multiple cables entry. Three procedures, Sisgeo supply a variety of accessories to and hydro-geological applications, to be embedded in
levels overvoltage protection (OVP) boards are available meet every clients’ requirement such as cable splicing concrete or buried into the soil.
to be assembled inside the junction boxes or onto DIN kits, connectors and cable end protections. In order to increase their performance and to suit every
guides to protect electrical instruments. Cable splicing kits for easy and fast cable joints is application, Sisgeo cables have high performance, and
Measuring switch boxes are available in different sizes composed by bi-component epoxy resin, plastic tubes, optional internal strength members or vented tube for
to connect up to 6, 12, 18 or 24 instruments. They are rubber glands, weldable printed boards and fittings. automatic compensation of atmospheric pressure for
also equipped with up to four 6-position rotary Cable end protection is a waterproof tube for the relative pressure transducers.
switches and connector for portable readout protection of the cable wire terminations; available in PE internal sheath and PVC external jacket assure
connection; their waterproof IP67 wall mounting plastic different sizes to suit all cable diameters. waterproof and mechanical properties.
enclosure with front door assures easy mounting and Flying Male waterproof connectors are fitted at factory Sisgeo cables comply with the following international
reading operation. to the instrument cable for direct connection to the standards (if applicable):
Simple measuring boxes are also available to connect portable readout unit.
• IEC 60540 • BS 6746 • IEC 60811
up to 3 instruments. They are fitted with waterproof Sisgeo also supplies different accessories and spare
• VDE 0207 • IEC 60228 • NFC 32200
connectors for each sensor input. parts for portable readouts: battery chargers, jumper
cables, etc…

TECHNICAL SPECIFICATIONS ACCESSORIES AND SPARE LIST CABLE LIST

JUNCTION BOXES ACCESSORIES INSTRUMENT CABLES


Available in different models up to 10 cable glands input. 0EGSM0K0200 CABLE SPLICING KIT (2 TUBES) 0WE102KEO00 2-LEADS 20-AWG CABLE, KEVLAR
0EPD0000000 JUNCTION BOX UP TO 10 INPUT with caps and epoxy resin PE inner + PVC outer jackets
with cable glands, IP67 0EGSM0K1000 CABLE SPLICING KIT (10 TUBES) 0WE104VWK00 2-TWISTED PAIRS 22-AWG CABLE
with caps and epoxy resin PE inner + PVC outer jackets
OVER VOLTAGE PROTECTIONS 1000RES2COR BI-COMPONENT EPOXY RESIN 0WE104VWS00 2-TWISTED PAIRS 22-AWG CABLE
0EPDP000W00 IP67 JUNCTION BOX FOR OVP 0,5 Kg pack PVC red jacket, OD 4.8 mm
Up to 30 leads OVP 0ECON07MV00 FLYING MIL CONNECTOR AND CAP 0WE104VWX00 2-TWISTED PAIRS ARMOURED
0EXKV302W00 3-LEVEL O.V.P., 2 LEADS 7 PIN male MIL connector CABLE PVC inner+S/S external jackets
0EXKV306W00 3-LEVEL O.V.P., 6 LEADS 0ETP0PG0700 CABLE END PROTECTION 0WE104X0200 ELECTRIC ARMOURED CABLE
0EPDP002W00 JUNCTION BOX WITH OVP, 2 LEADS for cable with OD 2.3 to 6.7 mm PE+PVC outer jacket, OD 8.0 mm
3-level OVP, IP67 box 0ETP0PG0900 CABLE END PROTECTION 0WE10600000 ELECTRIC CABLE 6 COND-24 AWG,
0EPDP006W00 JUNCTION BOX WITH OVP, 6 LEADS for cable with OD 4.8 to 8.0 mm PE inner + PVC outer jackets
3-level OVP, IP67 box 0ETP0PG1300 CABLE END PROTECTION 0WE106IPI00 ELECTRIC CABLE 6 COND-24 AWG,
for cable with OD 7.0 to 12.0 mm Polyuretane jacket, OD 5.0 mm
0WE110DX000 ELECTRIC CABLE 10 COND-24
SPARE PARTS AWG, PE inner + PVC outer jackets
0ECAV7P2A00 JUMPER SHIELDED CABLE, 2 ALL. CLIP
MIL connector and no. 2 clips + GND VENTED CABLES
0ECAV7P4A00 JUMPER SHIELDED CABLE, 4 ALL. CLIP 0WE203KEO00 2-LEADS VENTED CABLE, KEVLAR
MIL connector and no. 4 clips + GND PE inner + PVC outer jackets
0ECAV7P6A00 JUMPER SHIELDED CABLE, 6 ALL. CLIP 0WE207KE000 6-LEADS VENTED CABLE, KEVLAR
MIL connector and no. 6 clips + GND PE inner + PVC outer jackets
0ECAV07V200 FLYING SHIELDEDCABLE, 2 CONN.
MIL connector M/F 7 pins MULTICORE CABLES
MEASURING BOXES 0ECAVUSB110 USB CABLE, IP67 0WE11600000 8-TWISTED PAIRS 24-AWG CABLE
0EPM0000000 MEASURING BOX UP TO 3 INSTRUM. for ADK and portable dataloggers PE inner + PVC outer jackets
MIL connector, IP67 box 0WE13200000 16-TWISTED PAIRS 24-AWG CABLE
PE inner + PVC outer jackets
TERMINAL SWITCH BOXES
Available up to 6, 12, 18 or 24 position for 2-wire and ADK-100 INTERCONNECTING CABLE
6-wire instruments. 0ADKWE65000 CONNECTING CABLE MUX/ADK-100
0EPC0020S00 SWITCH TERMINAL BOX UP TO 24 POS. 3 m cable with #2 MIL connectors
For 2 wire instruments 0WE650T8A20 ADK-100 INTERCONNECTING CABLE
0EPC0060S00 SWITCH TERMINAL BOX UP TO 24 POS. 4+2 twisted pairs, PVC jacket
For 4 and 6 wire instruments

READOUTS, DATALOGGERS & ACCESSORIES 47 www.sisgeo.com


CONCRETE DAMS

EARTHFILL AND ROCKFILL DAMS

RCC DAMS

TAILING PONDS
DAM APPLICATIONS
Concrete dams Earthfill dams RCC dams

direct pendulum
inverted pendulum inclino-settlement column DEX system

strain gauge thermometer total pressure cell

rod extensometer tiltmeter tilt (beam) sensor

(DSM) hydraulic settlement system joint meter embankment extensometer

piezometer prism/optical target soil extensometer

water level meter accelerograph

PARAMETERS MEASURED AND INSTRUMENTS

EARTH-FILL AND ROCK-FILL DAMS CONCRETE AND RCC DAMS


Pore water pressure Piezometer Vertical deviation Hanging pendulums
Total pressure in soil Total pressure cell and lateral movement (direct and inverted)
Settlement of fill or soil Multipoint magnet Temperature in concrete Thermometer
extensometer Strain in concrete Strain-gauge
Horizontal extension Embankment (soil) or structural member
or contraction of fill or soil extensometer Long term load Load cell
Change in elevation Hydraulic settlement in rock bolts or tiebacks
with respect to known point gauge (DSM) Opening/closing of joint Joint-meter
Lateral (horizontal) Inclinometer, in-place in concrete
movement in fill or soil inclinometer (IPI) Rotational movement Tiltmeter, inclinometer
Rock foundation settlement DEX system
Slope deformation Tiltmeter and beam Up-lift pressure Piezometer
sensor Rock foundation settlement DEX system
Up-lift pressure Piezometer Extension or contraction Multipoint rod
Opening/closing of joint Joint-meter in borehole extensometer
of concrete slabs
Rotational movement Tiltmeter, inclinometer Change in elevation Settlement gauge,
Seepage and flow rate Weir, flow meter with respect to known point optical target, prism
Water level in the reservoir Pressure/level meter Seepage and flow rate V-notch weir, flow meter
Dynamic acceleration Accelerograph Water level in the reservoir Pressure/level meter
produced by seismic event Dynamic acceleration Accelerograph
produced by seismic event

dam applications 49 www.sisgeo.com


DEEP TUNNEL IN ROCK

CAVERNS AND MINES

OPEN EXCAVATION

SHALLOW TUNNEL
TUNNEL APPLICATIONS
Deep tunnel in rock Open excavation Shallow tunnel

DBS measuring anchor T-REX incremental extensometer DEX system

strain gauge convergence pin total pressure cell

rod extensometer beam tiltmeter inclinometer (IPI)

(DSM) hydraulic settlement system anchor load cell stress cell

piezometer prism/optical target steel lining load cell

accelerograph

PARAMETERS MEASURED AND INSTRUMENTS

TUNNEL MONITORING OPEN EXCAVATION


Convergence Tape extensometer, Long term load in rock bolts, Load cell
optical target tiebacks or anchors
Deformation of the rock Borehole rod Deformation of soil/rock Multipoint rod
mass around excavation extensometer around excavation extensometer
Strain in the lining Strain-gauge Soil/rock pressure Pressure cell
Stress in lining segments Stress cell, on the structure
strain-meter Stress in struts Strain gauge
Load on tunnel linings Pressure cell Lateral deformation Inclinometer, in-place
Front face deformation T-REX incremental of the excavation wall inclinometer (IPI)
extensometer Strain in concrete Strain-gauge, VW rebar
Load in rock bolts Load cell or structural member
or anchors Settlement/heave of T-REX extensometer,
Pore water pressure Piezometer the surrounding DEX system
Ground settlement/heave T-REX extensometer, Change in elevation Settlement gauge,
magnet extensometer with respect to known point optical target, prism
Deformation of the rock Rod extensometer, Lateral (horizontal) Inclinometer, in-place
mass around excavation DEX system movement around excavation inclinometer (IPI)
Deformation/rotation Tiltmeter, joint-meter, Up-lift pressure Piezometer
of adjacent buildings clinometer, crack-meter Deformation/rotation Tiltmeter, crack-meter,
Differential settlement DSM system, of adjacent buildings clinometer, joint-meter
of adjacent buildings tilt beam sensor Differential settlement DSM system,
Acceleration on the building Accelerograph, of adjacent buildings Tilt beam sensor
strong motion recorder Acceleration on the building Accelerograph,
Change in elevation with Settlement gauge, strong motion recorder
respect to known point optical target, prism

tunnel applications 51 www.sisgeo.com


www.gfstudio.com