DAELIM - WIKA - WASKITA JO

PROJECT : Civil Works for Construction of Karian Multipurpose Dam


TABLE J
ACCEPTANCE CRITERIA
STONE MASONRY

Minimum QC Testing
Test Parameter Test Method Acceptance Criteria Reference Location of Use Material
Frequency by Contractor
Stone for Masonry
Physical Prior to use and whenever Stone used in masonry shall be angular field, river Clause 3.10.2 of the Technical Specifications. Spillway, Road Works
Requirements character or source is changed. or quarry stone of approved quality, free from
seams and other defect
Specific Gravity ASTM C 127 (Standard Prior to use and whenever The stone shall have a specific gravity of not less Clause 3.10.2 of the Technical Specifications.
Test Method for character or source is changed. than 2.5.
Density, Relative
Density (Specific
Gravity), and
Absorption of Coarse
Aggregate)

Size Prior to use and whenever The maximum size of the masonry stone shall be Clause 3.10.2 of the Technical Specifications.
character or source is changed. two-thirds of the wall thickness.
Cement Mortar for Jointing
Ratio of Cement- Mix proportions The cement-sand ratio by volume is given in the Clause 3.10.3 of the Technical Specifications. Spillway, Road Works
Sand following table:
Type of stone masonry Ratio of cement-sand
Type A 1:3
Type B 1:4
Plastering
Ratio of Cement- Mix proportions The top of stone masonry structures shall be Clause 3.10.6 of the Technical Specifications. Spillway, Road Works
Sand finished neatly by plastering cement mortar with
mix proportion of one Portland cement and two
sand by volume (1 : 2).

Approved by, Prepared by,


Project Manager QC Manager
(..................................) (..................................)