Release notes

FieldCare 2.10.00
Document 1.01.00

Release notes
FieldCare 2.10.00

Endress+Hauser Process Solutions AG


Christoph Merian-Ring 12
CH 4153 Reinach/BL
Switzerland

Page 1 / 15
Release notes
FieldCare 2.10.00
Document 1.01.00

Table of Contents

1 FieldCare Revision History 3


2 Installation 6
3 Package description 7
4 Known issues and limitations 8
4.1 Security 8
4.2 Installation/Un-Installation 8
4.2.1 General issues 8
4.2.2 Windows Operating System specific issues 9
4.2.3 FieldCare Updates 9
4.3 Patches 9
4.4 General FieldCare functionality 10
4.5 W@M 10
4.6 Printing/Documentation 10
4.7 Transparent Gateway- and Placeholder DTM 11
4.8 HART 11
4.8.1 Usage of the RS232C interface 11
4.8.2 HART CommDTM 11
4.8.3 Endress+Hauser Fieldgate FXA520 11
4.8.4 Generic HART 11
4.8.5 Pepperl+Fuchs KFD2-HMM16 HART Multiplexer 11
4.8.6 Communication via HART Bluetooth and USB Modems 11
4.9 PROFIBUS 12
4.9.1 SOFTING (Trebing+Himstedt) DTM library 12
4.9.2 Softing PROFIdtm 12
4.9.3 Procentec PROFICORE / Commbricks 12
4.10 FOUNDATION Fieldbus 12
4.10.1 NI-Modem 12
4.11 Schneider EtherNet/IP 13
4.12 iDTM HART 13
4.12.1 Language Support 13
4.12.2 DDS Core issues 13
4.12.3 FieldCare “Create Network” 13
4.12.4 Error Message when updating iDTM library 13
4.12.5 Error Message after updating iDTM library 13
4.13 iDTM FOUNDATION Fieldbus 13
4.13.1 Language Support 13
4.13.2 Error Message after updating iDTM library 13
5 Microsoft .NET 13
5.1 Windows 7, SP1 13
5.2 Windows 8 14
5.3 Windows 8.1 14
5.4 Windows Server 2008 R2 15

Page 2 / 15
Release notes
FieldCare 2.10.00
Document 1.01.00

1 FieldCare Revision History

Product- Addition/Change
Version
2.01.00 New languages:
- French* & Italian*
2.02.00 New languages:
- Spanish* & Japanese*
Assistant for establishment of communication (Scanning Wizard)
Assistant for installation procedure (FieldCare Installation Manager)
Getting Started (Online Help)
New: Support Softing PROFIusb
New: FXA520 CommDTM, P+F Multiplexer DTM, SFC173 CommDTM
2.02.01 Update of FieldCare Frame Application
- Condition Monitoring Webreporter improvements
- Printout preview and device printout improvements
- Minor usability improvements
Update of HART Communication DTM
Update of P+F Multiplexer DTM
Update of SFC173 DTM
2.02.02 Update of P+F Multiplexer DTM
2.03.xx Update of the FieldCare Frame Application
- Log on
- Plant View Import/Export
- Inventory content could be copied to Clipboard (MS Excel)
- Document Management for Network and Plant View separated
- Performance improvements
Update of “HART Communication”
Update of “KFD2-HMM-16 P+F Multiplexer” DTM
Update of “SFC173 CommDTM” DTM
Update of PROFIBUS driver
New language:
- Chinese (traditional) *
Operating System phase out
- Windows NT
- Migration Manager for Data migration of Windows NT 4.0 SP6
New Operating System Support
- Windows Vista Business, Enterprise, Ultimate (x32)
New Communication DTMs
- Flow Communication FXA193/291 (Protocol Endress+Hauser Flow
Devices)
- PCP (Readwin) TXU10/FXA291 (Protocol Endress+Hauser “Phanten”
Devices)

Page 3 / 15
Release notes
FieldCare 2.10.00
Document 1.01.00

2.04.xx Update of the FieldCare Frame Application


- New variant FieldCare Device Setup (Successor of ToFTool/FieldTool
Package)
- Getting Started Video
- Log on without password (FieldCare Device Setup)
Update of “HART Communication” CommDTM
Update of “KFD2-HMM-16 P+F Multiplexer” CommDTM
Update of “ProfiDTM” CommDTM
New Operating System Support
- Windows 2003 Server, Standard, Enterprise (x32)
New Communication DTM
- IPC (Level, Pressure) FXA193/291 (Protocol Endress+Hauser
Level/Pressure Devices)
2.05.00 Update of FieldCare Frame Application
- DB Compactor introduced in FieldCare Utilities
- Documentation links for multiple devices possible
- Identification of a Single Device (HART) having more than one DTM in
the Network (Verify Network extended)
- Trebing+Himstedt DTM library integrated
DVD Variant introduced including DTM library and iDTM-HART
2.06.00 Update of FieldCare Frame Application
- Device Replacement Identification
- W@M Enterprise
- New license model
- Improved Launching Interface
- Improved Mobile Laptop Manager support
- COM-port identification
Update of CommDTM
- CDI, PCP, IPC
- HART, SFC173, Trebing+Himstedt DTM library
2.07.00 Update of FieldCare Frame Application
- FOUNDATION Fieldbus support
- Condition Monitoring
- Improved installation routine
- Microsoft .NET Framework 2.0/3.5
- W@M document upload
- license model (changed)
- frameINSPECTOR certified
Update of CommDTM
- CDI, PCP, ISS (Flow Communication FXA193/291)
- HART
- FOUNDATION Fieldbus H1 NI CommDTM (MEHT)
- Trebing+Himstedt DTM library
- Pepperl+Fuchs Multiplexer
Update of DeviceDTM Library
- HART, PROFIBUS, ISS, IPC, PCP, CDI
- FOUNDATION Fieldbus
Update of iDTM
- HART
- FOUNDATION Fieldbus

Page 4 / 15
Release notes
FieldCare 2.10.00
Document 1.01.00

Operating System phase out


- Windows 2000
DVD merge of Device Setup and PAM (Plant Asset Management)
2.08.00 Update of FieldCare Frame Application
- W@M Enterprise integration
- frameINSPECTOR certified
Update of all CommDTMs
Update of all DeviceDTMs
Update of all iDTMs
New Operating System: Windows 7
2.08.01 Additional Operating System: Windows 7 SP1
Installation and database improvements
- database server installation improved
- FR, IT issue fixed
Update of CommDTMs:
- SFC162
- T+H library
Import/Export project file size optimization
NOTE: Licenses valid for FieldCare 2.08.00 are also valid for FieldCare 2.08.01.
2.09.00 Operating Systems WinServer 2003 & Vista are discontinued
Installation speed improved
Support of HART7
Device Data Management
Connection Wizard
FieldCare frameINSPECTOR certified
USB issues fixed, all Endress+Hauser USB drivers are now activated
Update of CommDTMs
- SFG500
- HART CommDTM
2.09.01 New InstallationManager
Update of all DeviceDTMs
Update of all iDTMs
Windows 8 now Supported
Update of all DeviceDTMs
Update of all iDTMs
SFC162 & SFC173 removed (available on separate DVDs)
Update of DeviceDTMs
Update of CommDTMs
Update Installation Manager
New DeviceCare 1.00.42
Update of DeviceDTMs
Update of CommDTMs
Update Installation Manager
Update von DeviceDTMs
Update von CommDTMs
Update Installation Manager
OPC Server, OPC Client und KFD2-HMM-16 P+F Multiplexer CommDTM
removed
Update DeviceCare 1.01.07
Update iDTM now supporting Enhancements

Page 5 / 15
Release notes
FieldCare 2.10.00
Document 1.01.00

2.10.00 One Touch Network


Triple-S (SFG Speed Scan)
FDT 1.2.1 Scan
Modbus Support
EthernetIP Support
Russian language added
New Generic HART DTM
iDTM HART and FF updated
Several security patches
Update NI FF CommDTM
Update HART CommDTM
Update SFG500 CommDTM
Update of all DeviceDTMs
Windows 8.1 and WinServer 2008 R2 supported
Windows XP and WinServer 2003 discontinued
Device Setup is replaced by 30 days trial license
Update DeviceCare 1.02.00
Change from DeviceDTM library to single DTM installation
SOFTING DTM library is now automatically licensed
Update Generic HART
*Language and Operating System support for FieldCare frame application only.

2 Installation
Notes on installation are to be found in the Getting Started booklet (also supplied with the
DVD-ROM).

Page 6 / 15
Release notes
FieldCare 2.10.00
Document 1.01.00

3 Package description
Component Description of supported products
FieldCare Installation assistant for FieldCare, DeviceCare, DTMs and iDTMs.
InstallationManager
FieldCare FDT 1.2 conform frame application
DeviceCare FDT 2.0 frame application
HART HART via RS-232 or USB modem
Communication (Endress+Hauser FXA191, FXA195)
PROFIdtm DPV1 PROFIBUS FXA720 Fieldgate and Softing PROFIBUS (PCI, PCMCIA,
USB-devices)
Trebing+Himstedt SIEMENS DP/PA Link (IM157 + IM153-2)
DTM library ET200M (IM153)
ET200iSP (IM152
SIEMENS PROFIBUS Karten (CP5512+CP5611)
xEPI2 PROFIBUS Gateway
(for detailed information please refer to http://www.t-h.de)
P+F Multiplexer Support for Pepperl+Fuchs Multiplexer
- KFD0-HMS-16
- KFD2-HMM-16
- Mux 2700 Slave, Mux 2700F, Mux 2700G
(not included in this bundle but still supported after updating from
previous FieldCare versions)
FXA520 FXA520 CommDTM for HART communication via
Analog/GSM/Ethernet connection
Generic HART Universal device configuration for HART devices (to Standard Rev5)
DeviceDTM
PROFIBUS Profile Universal device configuration for PROFIBUS devices
DTMs (to Standard Profile 3.0) for level, temperature, pressure, flow,
actuator, discrete input, discrete output
SFG500 CommDTM PROFIBUS communication via Fieldgate SFG500
Flow Communication CommDTM (ISS) to communicate via FXA193/291 to
FXA193/291 Endress+Hauser Flow devices
IPC (Level, Pressure) CommDTM (IPC) to communicate via FXA193/291 to
FXA193/291 Endress+Hauser level and pressure devices
PCP (Readwin) CommDTM (PCP) to communicate via FXA291 to Endress+Hauser
TXU10/FXA291 “Phanten” devices
CDI CommDTM CommDTM (CDI) to communicate via FXA291 to Endress+Hauser
field devices.
FieldCare Utilities Installation assistant for FieldCare Utilities
InstallationManager
FieldCare CM Integration assistant to install “DTD” configuration files for
Integration Manager Condition Monitoring
Condition Monitoring FieldCare functionality to monitor status of connected devices
Endress+Hauser LCM Endress+Hauser offers Life Cycle Management functionality with
FieldCare version PAM (Plant Asset Management) – license
required
Envelope Curve Module to visualize offline stored curve files of field devices.
Viewer

Page 7 / 15
Release notes
FieldCare 2.10.00
Document 1.01.00

FOUNDATION FOUNDATION Fieldbus communication via National Instruments


Fieldbus H1 NI cards (additional hardware from National Instruments required
CommDTM including driver and configuration software)
DTM library* Endress+Hauser DeviceDTM library for these protocols:
- HART
- PROFIBUS
- FOUNDATION Fieldbus
- CDI, ISS, IPC, PCP
iDTM library* Endress+Hauser interpreter DTM library for these protocols:
- HART
- FOUNDATION Fieldbus
*The list of supported Device DTMs and iDTMs can be found in the Manufacturer Information or Device list.

The version information related to the above listed software components are to be found on
the FieldCare installation medium in the versions.txt file.

4 Known issues and limitations


4.1 Security
• The FDT/DTM technology is based on Microsoft XML technology. Issues concerning XML
might also affect Frame, CommDTM or DeviceDTMs. To ensure security please update
your Operating System regularly and apply measure like firewalls etc.
• Some DeviceDTMs might be susceptible for overload of interfaces (DOS attacks)

4.2 Installation/Un-Installation

4.2.1 General issues


 Installation Manager needs .NET 3.5 SP1 as prerequisite. This is available via
installation or enabling (see below)
For installation on the DVD at:
FieldCare\Software\System\Components\DotNet3\dotnetfx35.exe
 Installation Manager needs .NET 4.0 as prerequisite. This is available via installation.
A version is available on DVD in Common\DotNet
 Installation or un-installation needs to be done with Windows „Administrator‟ rights.
 The compliance to the system requirements is not checked. Please consult the
Technical Information of FieldCare for system requirements and operating system
needed. You may also consult the technical information by the driver manufacturer.
 Before starting the installation all running applications shall be closed, it is
recommended to restart the PC.
 To prevent loss of data it is recommend that data is saved before the upgrade
installation.
 The installation of FieldCare (VB Script) may cause virus scanner software to signal an
alarm. In such a case please contact your local system support to verify if this is a real
virus issue or just caused by the VB Script scan option of your virus scanner without
being an issue.
 During the installation of FieldCare it might be required to restart the computer up to 3
times because of the required system components: Microsoft Framework .NET3.5,
Microsoft Windows Installer 4.5 and Microsoft SQL Server 2008 Express.

Page 8 / 15
Release notes
FieldCare 2.10.00
Document 1.01.00

 Using the FieldCare Installation Manager for installation several blanks might appear
– this is due to the fact that some components where shifted to the Installation
Manager.

4.2.2 Windows Operating System specific issues


 General
o System requirements and Operating System Support are only related to the
FieldCare Frame Application; please also read the release notes of the DTMs.
 Installation mit Windows Server 2008 R2:
o Microsoft IIS uses port 80. To start the web reported it is necessary to adapted
either the port used by MS IIS or the port used by the webreporter.
 Languages
The Regional Settings for Non-Unicode Programs need to be changed to each region,
e.g. "Chinese (China)" for Chinese characters.

4.2.3 FieldCare Updates


 Update installation is technically possible for FieldCare versions: V2.02.00.835,
V2.02.01.853, V2.02.02.863, V2.03.00.1055, V2.04.00.1137, V2.05.00.1203,
V2.06.00.1266, V2.07.00.1424, V2.08.00.1538, V2.08.01, V 2.09.00 and V 2.09.01.
o It is recommended to perform updates only to the next higher version stepwise.
o FieldCare field trial versions are not automatically updated, please contact your
local Endress+Hauser Service for support.
 Updates from V2.0.0.200 and V2.01.00.383 are only possible if an update to FieldCare
V2.04.00 or higher has been performed before.
 Update from FieldCare V2.01.00 to newer versions can fail under Windows XP
o If the update fails, proceed as described:
- Download the Microsoft Hotfix KB917344 (JSSCRIPT 5.6) for your Operating
System.
- Delete the FieldCare database fmp.gdb (normally C:\Program
Files\Endress+Hauser\FieldCare\CM)
- Install the Hotfix and repeat the update procedure.
 Updates of FieldCare for Windows NT and Windows 2000 systems are no longer
supported. However FieldCare project data can be exported from those systems and
imported into FieldCare running on newer Windows systems.
 Exception:
o Projects exported with FieldCare V2.02.xx are not compatible to previous
FieldCare Versions.
 Update form FieldCare V2.08.01 to V2.09.00 might cause problems when files in
TEMP folder are deleted.
 Updating FieldCare from a different resource path requires browsing to resource
location.
 De-Installation of FieldCare 2.09.XX and subsequent installation of FieldCare 2.10.00
might cause issues with the SQL server installation. Please also de-install SQL server
completely or use standard update procedure.

4.3 Patches
 As part of FieldCare package you might also find patches to the latest version of
FieldCare.

Page 9 / 15
Release notes
FieldCare 2.10.00
Document 1.01.00

These patches are located in the folder \Common. In order to install these patches
please execute AppPatcher.exe.

4.4 General FieldCare functionality


 If a project is used which contains DTMs that have been deleted or uninstalled by the
system, an error message appears. Please update the DTM catalog after each
installation or un-installation of any DTM.
 Insufficient working memory, virtual memory or hard disk memory may cause
FieldCare to become unstable. Please refer to the section System Requirements of the
installation medium to verify your hardware is suitable to run FieldCare.
 Plant and Device Tags in inventory view are updated only using “Create Network”.
These Tags are updated just in case they were manually edited.
 Web-registration for a FieldCare PAM license in conjunction with Windows 2003
Server does not work, please contact your local Endress+Hauser sales organisation.
 Exports/Imports via *.csv files do not contain any ENP / I&M parameter
(ENP=Electronic Name Plate / I&M = Identification&Maintenance).
 The user management is disabled per default; it can be enabled using the FieldCare
Administration tool.
 The activity logging has been disabled per default.
 The texts in the activity logging are available in English only.
 The device ENP number is displayed in the network device info view.
rd
 “Create network” does not support Remote I/O or 3 party communication
components. You can manually assign DTMs to be recognized via “Create network”.
 Using one screen after using two screens before it may be that messages from
FieldCare are not displayed – please use TAB to access these messages.
 In order to use DTM data from DeviceCare the file type has to be changed from *.dcdtm
to *.fcdtm.
 Before starting Condition Monitoring “Guardian” the project needs to be saved.

4.5 W@M
 The FieldCare W@M function is disabled per default, it can be enabled using the
FieldCare Administration tool. W@M features can only be used together with a local
installation of W@M Enterprise or together with valid user-ID and password of a
W@M account.
To get a W@M account please contact your local Endress+Hauser sales representative.

4.6 Printing/Documentation
 Printing to a PDF file is not possible if there is no printer installed.
 In order to document the Plant View, the HOST PC must be selected: the corresponding
menu appears grayed if any other device is selected.
 Landscape printing is not supported.
 While printing an empty project an error message might appear.
 If an attempt is started to print an application report of an empty project, there might
be shown an error message.
 Error message while printing a report without having a printer installed.
 In case there is no printer installed on the computer any print operation will fail and
might result in an error message, especially while printing a report.

Page 10 / 15
Release notes
FieldCare 2.10.00
Document 1.01.00

4.7 Transparent Gateway- and Placeholder DTM


 It might be necessary to reassign this DTM for projects that were generated with
FieldCare 2.0.0.200.

4.8 HART

4.8.1 Usage of the RS232C interface


 HART communication cannot be shared with Endress+Hauser CommuWin. In order to
use CommuWin after FieldCare, either you have to reboot the computer or stop and
restart the COM Port driver manually. CommuWin II offers a tool for this purpose. The
tool is named C2hrtrst.exe and is located in the DDE Server directory and can be started
with following parameters: "c2hrtrst magic COMx" where x is 1, 2....
 Deactivate the FIFO buffer of the COM interface in the event of HART communication
problems.

4.8.2 HART CommDTM


 Trying to establish a connection with the CodeWrights HART Communication DTM and
MACTek USB Modem without having the modem physically connected will cause
errors.
 Issues may occur when connecting two modems FXA195 at the same time. To avoid
this, please disconnect one modem.
 You may only access virtual Comm Ports with admin rights. Using FieldCare standard
user rights may and therefore HART Comm Port with standard user rights may cause
errors.

4.8.3 Endress+Hauser Fieldgate FXA520


 Please refer to the release notes of the FXA520 on the accompanying installation
medium.
 Please contact the service in case of FXA520 compatibility issue with .NET2.
Workaround is available in service information.

4.8.4 Generic HART


 Parallel installation of Generic HART Version 3 and Version 6 is possible.

4.8.5 Pepperl+Fuchs KFD2-HMM16 HART Multiplexer


 For additional operating system information or frame applications please refer to the
according product specific release notes.
 The DTM is not released for third party frame applications.
If however the DTM is used within a third party FDT frame application,
Endress+Hauser will not guarantee correct functionality.
 Under certain conditions the P+F Multiplexer DTM can cause in accordance with .NET2
communication failures.

4.8.6 Communication via HART Bluetooth and USB Modems


 When connecting to a HART instrument via an USB or Bluetooth modem, there may
appear interruptions in the communication between instrument and another Host. In
this case the user has to ensure that the interruptions in the communication may not
lead to problems in controlling or observing the plant.

Page 11 / 15
Release notes
FieldCare 2.10.00
Document 1.01.00

4.9 PROFIBUS

4.9.1 SOFTING (Trebing+Himstedt) DTM library


 The Trebing+Himstedt release notes are included on the installation medium. These
release notes also contain a Hardware compatibility table.
 Trebing+Himstedt CommDTMs are working 30 days in evaluation mode. If you intend
to use it after this period in combination with a FieldCare PAM license, please send
your FieldCare Serial Number and Trebing+Himstedt “license.dat” file to
fieldcareregistration@solutions.endress.com, a full license will be returned within 6
working days.
 If a PROFIBUS driver is already installed (e.g. Siemens), the T+H library installation
overwrites at installation time the default settings for the PROFIBUS. It can result in
none running PROFIBUS based application anymore. The work around is to re-
instantiate the PROFIBUS default settings to work with the previous driver.
One consequence is that if various applications are running on the same PC and are
using different PROFIBUS driver, it must be foreseen to switch the driver before using
the according application.
To switch the drivers the Trebing+Himstedt installation provides several programs to
switch the driver assignments. Please refer to the Trebing+Himstedt DTM section in
your Windows START-menu folders.
 While using the ET200M with more than one HART device connected, the multiple
selection and connection to the HART devices might result in a non-connectivity status
of one or more devices even they are recognized and working properly.
The error message might be: "The communication DTM sent abort" or "The DTM did not
response to a request to shut down a connection to a device and is likely busy".
You can bypass this problem by selecting and connecting to each single device
separately.
Once this error appears a restart of FieldCare is required to reset the DTM connection
without losing any information.

4.9.2 Softing PROFIdtm


 The Softing PROFIdtm may be license restricted if you do not have administrator rights
and using FieldCare.
 WindowsXP Chinese: Softing PROFIdtm may not install properly. Install the PROFIdtm
a second time using FieldCare InstallationManager.
 Restart may be necessary to activate drivers in Windows.
 The Profiboard driver has to be installed separately.

4.9.3 Procentec PROFICORE / Commbricks


 Procentec PROFICORE / Commbricks can‟t be operated with Siemens DP/PA Link.

4.10 FOUNDATION Fieldbus

4.10.1 NI-Modem
 The installation of the NI drivers may be interrupted if Windows Installer >=4.5 is
installed on the computer. In this case, please take care to install the NI drivers before
FieldCare is installed.

Page 12 / 15
Release notes
FieldCare 2.10.00
Document 1.01.00

4.11 Schneider EtherNet/IP


 Schneider EtherNet/IP CommDTM is not capable to route networks.
 Schneider EtherNet/IP CommDTM does not Save and Load of parameter configuration.

4.12 iDTM HART

4.12.1 Language Support


 iDTM HART Software and Help are available in English language. The supported
languages for each device depend on the DD/EDD itself.

4.12.2 DDS Core issues


 In exceptional cases, it might be that DDs of the version 5 shall be used which are not
yet supported by the iDTM. In these special cases please remove the version 5 DDs
from the system and use the version 4 DDs instead.

4.12.3 FieldCare “Create Network”


 Handling of iDTM HART in FieldCare is identical as with any other DTM. It also
supports the FieldCare function “Create Network”, which scans the network for
available devices and automatically assigns the corresponding DTM or iDTM HART.
FieldCare V2.08.01 and higher will always assign the native DTM if available, else it
chooses iDTM.

4.12.4 Error Message when updating iDTM library


 When updating iDTM library from previous version an error message indicating
“Contact your support personnel” is displayed. Please press ok and proceed.

4.12.5 Error Message after updating iDTM library


 After updating iDTM library from previous version an error message indicating
“Duplicate device types are found…” is displayed. Please ignore and proceed.

4.13 iDTM FOUNDATION Fieldbus

4.13.1 Language Support


 iDTM FOUNDATION Fieldbus Software and Help are available in English language. The
supported languages for each device depend on the DD/EDD itself.

4.13.2 Error Message after updating iDTM library


 After updating iDTM library from previous version an error message indicating
“Duplicate device types are found…” is displayed. Please ignore and proceed.

5 Microsoft .NET
5.1 Windows 7, SP1
• Go to “Control Panel\All Control Panel Items\Programs and Features” and click on turn
Windows features on or off.
• Enable Microsoft .NET Framework 3.5.1.

Page 13 / 15
Release notes
FieldCare 2.10.00
Document 1.01.00

A version of .NET 4.0 is available in the Common folder on the DVD.

5.2 Windows 8
• Go to “Control Panel\All Control Panel Items\Programs and Features” and click on turn
Windows features on or off.
• Enable .NET Framework 3.5 (includes .NET 2.0 and 3.0)

5.3 Windows 8.1


• Go to “Control Panel\Programs\Programs and Features” and click on turn Windows
features on or off.
• Enable .NET Framework 3.5 (includes .NET 2.0 and 3.0)

Page 14 / 15
Release notes
FieldCare 2.10.00
Document 1.01.00

5.4 Windows Server 2008 R2


• Go to “Control Panel\Programs\Programs and Features” and click on turn Windows
features on or off.
• Enable .NET Framework 3.5 (includes .NET 2.0 and 3.0)

Page 15 / 15