NOTES

ROOF: ALUMINIUM CORRUGATED CHROMADEK


STEEL PALISADES BY SPECIALIST
portal frame for the roof fixed to wall 114x38mm s.a pine wall plate
SANS 10400-T-2011. Edition 3
embedded at least 300mm into brickwork with connecting devices according to
STEEL PALISADES 4.9.2 table l2, schedule 1, of sabs 0400
b) ANY DOOR BETWEEN SUCH GARAGE & ANY all web members to be minimum 38x114mm grade 4 with equal bays smaller
than 1500mm. approaved bracing must prevent buckling and keep trusses upright
SUCH ROOM SHALL HAVE A FIRE RESISTANCE valley and hip rafters to be grade 6 50x228 sa pine
OF NOT LESS THAN 30minutes & SUCH laminated timber to comply with sabs 876

170
50mm glass fibre insulation to be installed on ceiling
CEMENT / EQUALLY APPROAVED
DOORWAY SHALL REQUIRE A THRESHOLD
CAPPING & WATER PROOFING CONCRETE ROOF
OF NOT LESS THAN 10mm & -CONCRETE ROOF TO ENGINEER'S DETAIL WITH MINIMUM 50mm THICKNESS
440x440mm BRICK PIER
c)NO COMBUSTIBLE ROOF COMPONENTS -VERMICULITE SCREED GRADED TO 1:50 FALL TO 100m DIAMETER BILD IN DOWNPIPES
STEEL PALISADES TO
SPECIALIST DESIGN AND SHALL PENETRATE THE SEPARATING ELEMENT -WATERPROOFING BY SPECIALIST WITH A TEN YEAR GUARANTEE AS PER SPECIFICATION
SPECIFICATIONS DIVIDING THE SPACE BETWEEN THE GARAGE FLOORS AND WATERPROOFING
steel palisades by specialist -GROUND FLOOR SLAB=85mm THICK 20mpa CONCRETE PERFECTLY LEVEL AND AT
450x220mm THICK BRICK WALL & THE HABITABLE ROOM
MINIMUM 150mm ABOVE GROUND LEVEL ON PROPERLY COMPACTED HARDCORE FILL
PAINTED & PLASTERED
-25mm THICK SCREED AND FINISHES AS INDICATED
440x440mm 440x440mm TO CLIENT'S COLOUR & CHOICE
-SUSPENDED CONCRETE FLOOR SLABS TO ENGINEER'S DETAIL AND SPECIFICATIONS
BRICK PIER BRICK PIER -DPC UNDER ALL WALLS (EXCEPT FREE STANDING), FLOORS AND WINDOW SILLS
AND TO ALL VERTICAL CHANGES IN FLOOR LEVELS
600x230mm CONC FOOTING -FLUSHINGS TO ALL PARAPETS AND CHANGES IN ROOF LEVELS

FROM CATCHPIT FITTED WITH GRATING AND SILT TRAP


-PLANTERS TO BE WATERPROOFED AND DRAINAGE INSTALLED

FOUNDATIONS, BRICKWORK & PARTITIONS


-ALL FOUNDATIONS TO BE 25mpa CONCRETE , AT LEAST 200x700mm. MINIMUM
200mm UNDER GROUND TO ENGINEER'S DETAILS AND SPECIFICATIONS
-BOUNDARY WALLS' FOUNDATION MUST NOT ENCROACH ON BOUNDARY AND WALLS
ARE TO BE PLASTERED AND PAINTED ON THEW INNER WALL
114x38mm ROOF TRUSSES -PARAPET WALLS TO BE ATLEAST 300mmHIGH AND MAXIMUM 500mm WITH BRICKFORCE
ALUMINIUM CORRUGATED CHROMADEK IN EVERY COURSE
-ALL SCREEN WALLS TO BE AT LEAST 1800mm HIGH ABOVE GROUND LEVEL
-LINTOLS TO BE SUPPORTED MINIMUM 150mm FOR OPENINGS UPTO 4800mm.BRICKFORCE
TO BE BUILT IN EVERY COURSE BELOW FLOOR LEVEL AND ABOVE WINDOW LEVEL, EVERY
ALUMINIUM CORRUGATED CHROMADEK THIRD COURSE BETWEEN BETWEEN IN CONTINOUS BANDS
50x76mm PINE PURLIN -NO TEETHING OR BLOCK BONDING WILL BE ALLOWED UNDER ANY CIRCUMSTANCES
AT 750 C/C MAXIMUM -ANY PARTITION TO BE RODENT PROOF

152x32mm TIE BEAM STAIRS AND BALUSTRADES


(CEILING JOIST) -STAIRS TO BE 750mm MIN WIDTH, TREADS 300mm , RISERS 170mm WITH 6mm MAX DEVIATION
-1000mm HIGH BALUSTRADES TO ALL STAIRS AND BALCONIES
-MAX 3000mm VERTICAL RISE PER FLIGHT , WINDERS WHERE SHOWN ,TO BE AT LEAST 250mm
38x38mm S.A BRANDERINGS WIDE, 450mm FROM THE NARROW END AND ANGLE BETWEEN THE RISERS TO BE CONSTANT
-MINIMUM HEADROOM TO BE 2100mm MEASURED FROM PICHLINE
-GLASS BALUSTRADES (IF SHOWN ) TO BE SAFETY GLASS

GLAZING

portal frame for the roof fixed to wall 114x38mm s.a pine wall plate CORNICE TO CLIENT CHOICE
/ EQUALLY APPROAVED
embedded at least 300mm into brickwork with connecting devices according to -BATHROOM WINDOWS TO BE FROSTED GLASS
table l2, schedule 1, of sabs 0400 6.4mm THICK BY 900MM WIDE
-ALL GLAZING ON DOORS TO BE SATETY GLASS
all web members to be minimum 38x114mm grade 4 with equal bays smaller GYPSUM CEILING BOARD FIXED
-ALL GLAZED AREA LESS THAN 300MM ABOVE FFL TO BE COVERED WITH SATETY GLASS
than 1500mm. approaved bracing must prevent buckling and keep trusses upright ON 38x38mm BRANDERING
valley and hip rafters to be grade 6 50x228 sa pine INTO BRICKWORK SPACED AT 450x900mm c/c FIXED
ALUMINIUM CORRUGATED CHROMADEK laminated timber to comply with sabs 876 10mm THICK EXTERNAL AREA SCHEDULE
50mm glass fibre insulation to be installed on ceiling 10mm THICK INTERNAL ON 52x152mm CEILING JOIST \
PLASTER EXISTING FLOOR AREA =
PLASTER TIE BEAM
NEW FLOOR AREA =
TOTAL FLOOR AREA =

SITE PLAN AREA =

SITE COVERAGE = %

DOORS & WINDOWS SCHEDULE


SEE SCHEDULE DRAWINGS OF DOORS AND WINDOWS

DO NOT SCALE THE DRAWINGS


BIC
fire wall ELECTRICAL KEY
WHB B
LIGHT SWITCH
fire wall
fire wall

shower
WHB
BIC BIC
B
shower
BIC

WHB

WC