Additional Resources Question: I have a vessel design that requires an "RT2" designation. I selected 100% (full) RT on the longitudinal seams and Spot RT on
the circumferential (girth) seams but the COMPRESS summary reports "RT3" in the summary report. How do I get COMPRESS
FAQs by Topic to report "RT2"?
COMPRESS provides options to specify special versions of Spot radiography that indicate the requirements of UW-11(a)(5)(b)
have been met for that joint; both Type 1 and Type 2 joints are available. In the typical head dialog below, there are selections
near the top of the radiography list for "Spot UW-11(b)". Further down the list are selections for "Spot UW-11(a)(5)(b)". Selecting
these for all applicable seams will cause COMPRESS to report an RT 2 designation for the vessel. Note that the Code may
require additional spot radiographs in order to meet UW-11(a)(5) and therefore RT 2.