Вы находитесь на странице: 1из 1

Working Together to Provide Flow THE LEADER IN SAND, PIG, LEAK, AND CORROSION-EROSION MONITORING

Assurance Solutions for over 15 Years flow assurance loves chemistry


Polyurethane Solutions from BASF help develop custom tailored and economically viable products
for the subsea sector. From products for thermal insulation, bend stiffeners, pigs, strakes, field
PERMA-PIPE 
joints to cable protection – and much more. Because at BASF, we create chemistry.
OIL & GAS U LT R A S O N I C I N T E L L I G E N T S E N S O R S

WESTERN HEMISPHERE: EASTERN HEMISPHERE:


Perma-Pipe Oil & Gas BASF Corporation Houston, Texas Bergen, Norway
866.856.SAND 281.492.9805 www.clampon.com +47 5594 8850
Tel: 281-598-6222 Tel: 734-324-6309 281.492.9810 FAX 24/7/365 Service +47 5594 8855 FAX For more information, call: 734-324-6309, e-mail: puroffshore@basf.com, www.polyurethanes.basf.us
Email: reuserh@permapipe.com Email: puroffshore@basf.com email: info@clamponinc.com email: mail@clampon.com

PerPip_OSmaps_1204 1 3/14/12 4:13 PM Clamp_OSmaps_1204 1 1/25/12 8:54 AM BASF_OSmaps_1204 1 3/14/12 4:14 PM


Shawcor_OSmaps_1204 1 2/21/12 11:46 AM

2012 SURVEY OF OFFSHORE


SOLUTION TYPES
U-VALUE (Btu/hr-ft2-°F) CONNECTION
WATER DEPTH (ft) VENDORS ISSUES ACTIVE SYSTEMS PASSIVE SYSTEMS OTHER INNOVATIVE METHODS DETECTION SYSTEMS EXPERIENCE APPLICATION
Based on PL OD METHOD
TYPE CHARACTERISTICS TYPE CHARACTERISTICS TYPE ADVANTAGES

NON-CHEMICAL field proven

REDUCES / ELIMINATES CHEMICAL REQUIREMENTS

REDUCES / ELIMINIATES ENERGY REQUIREMENTS


PROtotype

PROTOTYPE TESTED FOR HYDROCARBON USE


FLOW ASSURANCE SOLUTIONS
Conceptual

FLOW OPTIMIZED SYSTEM ARCHITECTURE

TOTAL INSTALLED LENGTH SUBSEA (mile)

MAXIMUM WATER DEPTH INSTALLED (ft)


INVESTIGATED-ENGINEERED-DESIGNED
INCREASE TEMPERATURE / PRESSURE

RISER (R), JUMPER (JPR), JOINT (JT),


MAXIMUM WATER DEPTH TESTED (ft)
INTERNALLY INSULATED CORROSION
FREQUENCY OR CONTINUOUS USAGE

U-VALUE BASED ON PL OD (RANGE),

MINIMIZES CAPEX / INSTEX / OPEX

FIBER OPTICS - PLUG DETECTION


FLUID TYPE USED (CIRCULATION)

UNINSULATED PIPE (COLD FLOW)


DENSITY: 1lbm/ft³=16.03 kg/m³
POWER REQUIREMENTS / MILE
EMULSION / FOAMING / SCALE

WELLBORE (W), FLOWLINE (F),


1Btu/(lbm-◦F)=4186.8J/(kg-K)
PIPELINE JACKET INSULATION
COILED TUBING REMEDIATION

COILED TUBING REMEDIATION


McDermott Subsea

ACOUSTIC - PLUG DETECTION


0.01 (Btu/hr.ft2.°F) - 0.06 W/m2.K

Btu/(hr-ft-°F) = 1.73W/(m-K)

PHASE-CHANGE INSULATION
100 (Btu/hr.ft2.°F) - 567 W/m2.K

0.05 (Btu/hr.ft2.°F) - 0.3 W/m2.K

INSTALLED SURFACE APPL.


COATING THICKNESS (inch)
50 (Btu/hr.ft2.°F) - 284 W/m2.K

0.5 (Btu/hr.ft2.°F) - 2.8 W/m2.K

0.1 (Btu/hr.ft2.°F) - 0.6 W/m2.K

TFL (THROUGH FLOW LINE)

INSULATED FLEXIBLE PIPE

INSTALLED SUBSEA APPL.


NON INVASIVE CLAMP-ON

GAS CONDENSATE FIELDS


HOT FLUIDS CIRCULATION
10 (Btu/hr.ft2.°F) - 57 W/m2.K

PIPE-IN-PIPE INSULATION
EXOTHERMIC PROCESSES
Products & Systems Methodologies

THERMAL CONDUCTIVITY
1 (Btu/hr.ft2.°F) - 5.7 W/m2.K
5 (Btu/hr.ft2.°F) - 28 W/m2.K

OFFSET DISTANCE (Mile)

OFFSET DISTANCE (Mile)

FLOWRATE MONITORING
757 N. Eldridge Pkwy

PRESSURE MONITORING

MANIFOLD (M), TREE (T)


LINED PIPE (INTERNAL)

INTERNAL INSULATION
BUNDLED FLOWLINES
ELECTRICAL HEATING

VACUUM INSULATION

RESISTANT PIPELINE
Houston, Texas 77079

PRESSURE RATINGS
SAND MONITORING
COLLAPSIBLE PIPE
10,000 ft. (3050m)

PIG MONITORING
4,000 ft. (1220m)

5,000 ft. (1525m)

6,000 ft. (1830m)

7,000 ft. (2135m)

8,000 ft. (2440m)

9,000 ft. (1745m)


Phone: (281) 870-5000; Fax: (281) 870-5520/5210/5807

PHOTO NUMBER

HEAT CAPACITY
1,000 ft. (305m)

2,000 ft. (610m)

3,000 ft. (915m)

(Btu/hr-ft2-°F )
RISER TOWERS

HP / HT FIELDS
REMEDIATION
E-Mail: business.development@mcdermott.com

BURIED PIPE
DETECTION

INTEGRATE

OIL FIELDS
HYDRATES

SLUGGING

COLLARS
Website: www.mcdermott.com

WELDS
Poster Compiled By: C-Ray Media, Inc.

WAX
0 ft.
ADVANCED INSULATION SYSTEMS LTD
Poster Graphics by Xenon Group – www.xenongroupdesign.com Contact: William Rivers & Sarah Lehman; 19424 Park Row, Ste. 102, Houston, TX 77084; Phone: +1 281-944 9027 & Kevin Firth; Quedgely West Business Park, Gloucester, UK +44 (0)1452 880880. E-Mail: info@aisplc.com; Website: www.aisplc.com
5,750 10,000 0.20 1 ContraTherm C55-750-30 Phenolic Based Pack-In-Place Syntactic Foam Subsea Insulation H H 0.116 0.50-10.00 0.2-1.0 H H H H H H H H H 10,000 5,500 H H H F, R, JPR, JT, M, T
8,200 10,000 0.20 2 ContraTherm C55-800-03 Phenolic Based Pack-In-Place Syntactic Foam Subsea Insulation H H 0.11 0.50-10.00 0.2-1.0 H H H H H H H H H 10,000 5,500 H H H F, R, JPR, JT, M, T
8,200

APRIL 2012
10,000 0.20 3 ContraTherm C25-770-01 Syntactic Silicone Subsea Insulation H H 0.1057 0.50-10.00 0.2-1.0 H H H H H H H H H 10,000 5,500 H H H F, R, JPR, JT, M, T

M A G A Z I N E 0.20 4 ContraFlame JF120 Lightweight Passive Fire Proof Protection and Insulation System H H 0.029 0.75 0.2-1.0 H H H H H H H H H Surface Surface H H H F, R, JPR, JT
0.20 5 ContraFlex Jet Fire Rated Flexible Protection Jackets H H H 0.029 0.75 0.2-1.0 H H H H H H H H H Surface Surface H H F, R, JPR, JT
1455 West Loop South, Suite 400; Houston, TX 77027 5,000 10,000 6 C.TAG High Visibility, Non Toxic, Anti-fouling Subsea Markers H H H H 5,000 H H F, R, JPR, JT

For additional paper copies or comments E-mail: posters@pennwell.com. Tel: 713-621-9720; Fax: 713-963-6296 ASPEN AEROGELS, INC. Contact: Mario Saba - Hydrocarbon Processing; 30 Forbes Rd., Bldg. B, Northborough, MA 01532; Phone: 514-487-8693; Fax:508-691-1200; E-Mail: msaba@aerogel.com; Website: www.aerogel.com
PDF Downloads available at www.offshore-mag.com. Electronic Data Available. www.offshore-mag.com 10,000 0.02 7 Spaceloft™ Subsea Aerogel Pipe-in-Pipe (PIP) Insulation H H H H H H H H H H H MIN H H H H H H H H H H 0.008 0.2-3.0+ 0.01-0.5 H H H H H H Possible H H H H H H H 227 na 12,000 H H H F, R, JT
10,000 0.02 8 Pyrogel™XT Aerogel Hi Temperature Insulation H H H H H H H H H H H H H H H H H H H H 0.013 0.1-10.0+ 0.01-0.5 H H H H H H Possible H H H H H H H H na 12,000 H H H F, R, JT
10,000 0.02 9 Cryogel™ Z Aerogel Cryogenic Pipe Insulation H H H H H H H H 0.006 0.2-10+ 0.01-0.5 H H H H H H Possible H H H H H H na na
1 2 3 4 5 6
BASF Contact: Karl Gust - Market Manager or Ian Lynam - Business Development Manager; 1609 Biddle Avenue, Wyandotte, MI 48192; Telephone: 734-324-6309; E-Mail: karl.gust@basf.com; ian.lynam@basf.com ; puroffshore@basf.com; Website: www.zerohg.com
10,000 0.4 10 ELASTOSHORE® ZEROHg™ Glass Syntactic Polyurethane (GSPU) for Flowlines & Jumpers H H H H H H H 0.07 0.5-4.0 0.4-2.0 0.35 51 H H H H H H H H 160 10,000 10,000 H H H F, R, JT,JPR
10,000 0.4 11 ELASTOSHORE® ZEROHg™ Glass Syntactic Polyurethane (GSPU) for Subsea Equipment H H 0.07 0.5-4.0 0.4-2.0 0.35 51 H H H H H H H H 10,000 5,600 H H H F, R, JT,JPR, M, T
5,000 10,000 0.4 ELASTOSHORE® ZEROHg™ Glass Syntactic Polyurethane (GSPU) for Connector Shrouds H H 0.07 0.5-4.0 0.4-2.0 0.35 51 H H H H H H H H 10,000 5,000 H H H F, R, JT,JPR, M, T
575 1,000 0.15 ELASTOPOR® Mid to High Density Polyurethane Wet Insulation H H H H H H H H 0.02 0.5-5.0 0.15 0.35 15 H H H H H H H H H 50 650 575 H H H F, R, JT
7,500 10,000 0.10 ELASTOPOR® Polyurethane Foam for Pipe In Pipe Applications H H H H H H H 0.015 0.5-4.0 0.1 0.35 4 H H H H H H H H 250 10,000 7,500 H H H F, R, JT
100 0.03 ELASTOPOR® Mid Density Polyurethane Foam For Cryogenic Applications H H 0.0125 0.5-6.0 0.03 0.35 4 H H H H H H H H 5 H F, R,JT
7,320 >0.27 TRIDENT™ Glass Syntactice Polyurethane for Subsea Equipment H H H H H 0.093 0.5-6.0 >0.27 0.343 53 H H H H H H H H 7,320 H H H F, R, JT, JPR, M, T

7 8 9 10 11 12 BREDERO SHAW COMPANY Contact: Eirik Simonsen VP, Global Flow Assurance, Adam Jackson Tec. Mgr Global Flow Assurance; 3838 N. Sam Houston Pkwy East, Suite 300, Houston, TX 77032; Telephone: 281-886-2350; E-Mail: esimonsen@brederoshaw.com; ajackson@brederoshaw.com; Website: www.brederoshaw.com
6,500 10,000 0.5 12 Thermotite® Polypropylene Field Joint Coating H H H H H H H 0.20 5.0 0.50 H H H H H H 1,000 10,000 6,500 H H H F, R, JPR, JT
6,000 9,000 0.5 Thermoflo® Polyurethane Field Joint Coating H H H H H H H 0.17 5.0 0.40 H H H H H H 400 9,000 6,000 H H H F, R, JPR, JT, M, T
3,000 10,000 0.5 Thermotite® ULTRA™ Filed Joint Coating H H H H H H H 0.16 5.0 0.30 H H H H H H 50 10,000 3,000 H H H F, R, JPR, JT
6,000 10,000 0.5 13 Thermotite® Polypropylene Custom Coating H H H 0.20 5.0 0.50 H H H H H H 10,000 6,000 H H H JPR, M
6,000 9,000 0.5 Thermoflo® Polyurethane Custom Coating H H H 0.16 5.0 0.40 H H H H H H 9,000 6,000 H H H JPR, M, T
2,000 0.6 14 4 Layer Polypropylene Foam H H H H H H 0.10 2.5 0.62 H H H H H H H H 210 2,000 2,000 H H H F, R
4,600 9,200 unlimited 0.75 4 Layer Polypropylene Solid H H H H H H 0.13 2.5 0.75 H H H H H H H H 210 2,000 2,000 H H H F, R
1,150 0.28 15 ThermoFlo® - S H H H H H H 0.07 4.0 0.28 H H H H H H 984 950 H H F, R, JT, JPR, M
13 14 15 16 17 18 4,200 0.36 16 ThermoFlo® - D1400 H H H H H H 0.09 4.0 0.36 H H H H H H 170 3,600 3,400 H H F, R, JT, JPR, M
5,600 5,900 0.37 ThermoFlo® - D2000 H H H H H H 0.09 4.0 0.37 H H H H H H 75 5,740 5,600 H H F, R, JT, JPR, M
575 7,400 8,500 0.41 ThermoFlo® - D2800 H H H H H H 0.10 4.0 0.41 H H H H H H 22 7,874 7,400 H H F, R, JT, JPR, M
2,000 0.42 17 Thermotite® Polypropylene Foam H H H H ATD H ATD H H H 0.10 4.0 0.42 H H H H H H H 250 1,300 1,300 H H H F, R, JT, JPR
7,200 10,000 0.41 Thermotite® Polypropylene Syntactic H H H H ATD H ATD H H H 0.10 4.0 0.41 H H H H H H H 40 9,000 7,200 H H H F, R, JT, JPR
6,000 0.39 Thermotite® Polypropylene Syntactic (s35) NEW H H H H ATD H ATD H H H 0.09 4.0 0.39 H H H H H H H H H F, R, JT, JPR
7,200 9,000 0.44 Thermotite® Deep Foam (High Density) H H H H ATD H ATD H H H 0.10 4.0 0.44 H H H H H H H 35 9,000 7,200 H H H F, R, JT, JPR
7,000 0.36 Thermotite® Deep Foam (Low Density) H H H H ATD H ATD H H H 0.09 4.0 0.36 H H H H H H 0 7,000 –– H H H F, R, JT, JPR
7,200 10,000 0.44 18 Thermotite® Polypropylene Composite System H H H H ATD H ATD H H H ATD 4.0 0.44 H H H H H H H 15 7,000 7,200 H H H F, R, JT, JPR
19 20 21 22 23 24 3,000 5,000 0.32 19 Thermotite® ULTRA™ Foam NEW H H H ATD H H H 0.07 4.0 0.32 H H H H H H 5,000 H H F, R, JT, JPR
9,000 unlimited 0.37 Thermotite® ULTRA™ Solid NEW H H H ATD H H H 0.09 4.0 0.37 H H H H H H 10,000 3,000 H H H F, R, JT, JPR
CABOT AEROGEL Contacts: Matt Greenfield, Commercial Manager: 157 Concord Rd., Billerica, MA 01821; Tel 978-670-NANO; Fax 978-670-7045. Email: mattew_greenfield@cabot-corp.com Raj Saxena, Sales Manager: 4582 Kingwood Dr. Suite E145, Kingwood, TX 77345; Tel 281-361-2330; Fax 281-361-3119. Email: raj_saxena@cabot-corp.com; Website: www.nanogel.com
10,000 0.02 20 AEROGEL COMPRESSION PACK™ H H H H H H H H H H H 0.008 0.5-8.0 0.02-0.5 H H H H H 10,000 H H H F, R, JT
10,000 0.02 21 AEROGEL THERMAL WRAP™ H H H H H H H H H H H 0.012 0.1-12.0+ 0.02-0.5 H H H H H 10,000 H H H F, R, JT
10,000 0.02 22 AEROGEL PARTICLES H H H H H H H H H H H 0.010 0.1-12.0+ 0.02-0.5 H H H H H 10,000 H H H F, R, JT
CLAMPON, INC. Contact: Justin Curry - Houston Area Sales Manager; 15720 Park Row, Ste. 300, Houston, TX 77084; Phone: (281) 492-9805; Fax: (281) 492-9810; E-Mail: Justin.curry@clamponinc.com; Website: www.clampon.com
10,000+ 23 DSP-II Particle Monitor (Sand) H H H H H H H H 14,850 10,000 H H H F, R, PL, JPR, M, T
6,800 10,000+ 24 Subsea Corrosion-Erosion Monitor (CEM) H H H H H H H H 10,000 6,800 H H H F, R, PL, JPR, M, T
25 26 27 28 29 30 8,800 10,000+ 25 DSP Pig Detector H H H H H H H H 14,850 8,800 H H H F, R, PL, JPR, M, T
1,320 10,000+ DSP Leak Detector H H H H H H H H 14,850 1,320 H H H F, R, PL, JPR, M, T
1,600 10,000+ DSP-II Vibration Monitor H H H H H H H 10,000 1,600 H H H F, R, PL, JPR, M, T
DYNA MONITORING CORPORATION Contact: Glen Sumner - 8306 Leafy Lane, Houston, Texas 77055; Phone 713-973-7285; Fax 713-973-7286; E-mail: glen.sumner@sbcglobal.net
2,100 8,000 10,000 1.3-0.2 26 Aqua Therm Submersible Insulation - (solid, very cost effective) H H H H H H H 0.095 >1 0.2-1.3 0.48 59.9 H H H 1 to 25 H H 8,000 2,100 H H H F, R, JT, JPR, M, T
1,500 4,500 8-0.37 27 Hysulate Submersible Insulation (400 degree operating temperature) H H H H H 0.017 >0.25 0.37-8 0.36 55 H H H H H 4,500 1,500 H H H W, F, R, JT, JPR,M, T
4,500 Proprietary electric flowline heating (return cable optional) H H H H C Y 0-25 H H H H H 1 to 25 H H 4,500 H H H F, R, JT, JPR
FMC TECHNOLOGIES Contact: Akash Patel - Global Sales Manager - 11220 TC Jester Blvd, Houston, TX 77067; Phone 281-405-7811; E-mail: akash.patel@fmcti.com or Frank Wabnitz - Global Product Manager; 11220 TC Jester Blvd., Houston, TX 77067; Phone: 281-591-4327; Email: frank.wabnitz@fmcti.com; Website: www.fmctechnologies.com

31 32 33 34 35 36 9,596 0.35-0.12 28 Novolastic™ H H 0.1 AR > 0.01 0.35 59.3 H H H H H H 10,000 9,596 H H JPR, JT, M, T
ITP INTERPIPE Contact: (Europe) - Wayne Grobbelaar; 11 Quai Conti, 78430 Louveciennes, France; Phone: (+33) 139 180 000; wayne.grobbelaar@itp-interpipe.com; Website: www.itp-interpipe.com
4,800 10,000 0.4-0.05 29 Highly Insulated Double Wall Pipe H H H H 0.0030-0.01 0.2-1 0.05-0.4 H H H 60 H H H H 160 10,000 4,800 H H H F, R, J
10,000 0.4-0.05 30 Light Weight Double Wall Pipe H H H H 0.0030 <1 0.05-0.4 H H H 60 H H H 10,000 H H H F, R
10,000 0.4- 0.15 31 Ultimate Pipe H H H 0.010 <1 0.15-0.4 H H H 40 H H H 10,000 H H F, R, J
10,000 0.3-0.05 32 McPipe (10 Days Cooldown) Developed w/ J. Ray McDermott, Inc. H H H H 0.0030 1-2 0.05-0.3 H H H H 60 H H H 10,000 H H F, R, J
6,500 10,000 0.25-0.05 33 Heat Traced Pipe H H H 8-20 kW H H 0.0030 <1 0.05-0.25 H H H 60 H H H 6,500 H H F, R, J
50 0.1-0.01 34 LPG Refrigerated Pipe H 0.0030 1-2 0.01-0.1 H H 15 H H H H H 4 50 50 F, R
50 0.03-0.01 35 LNG Cryogenic Pipe H 0.0025 2 0.01-0.03 H H 15 H H H 50 F, R
37 38 39 40 41 42 NEXANS NORWAY Contact: Marc Joyce - VP Business Development; 16420 Park Ten Place, Suite 580, Houston, TX 77084; Phone: 281-578-6900; Fax: 281-578-6991; E-Mail: marc@nortech.com; Website: www.nortech.com or Eldar Ystad, Innspurten 9, PO Box 6450, 0605 Oslo, Norway; Phone: 4722886321; Fax: 4722886378; E-Mail: eldar.ystad@nexans.com; Website: www.nexans.com
1,200 2,790 10,000 1.76-0.52 DEH H H H H H H H H 0.1 .52-1.76 H H H H H H 140 3,500 1200 H H H F, JT, R
PERMA-PIPE OIL & GAS Contact: Hank C. Reuser - Vice President or Larry King - Sales Manager; 281- 598-6222; E-Mails: reuserh@permapipe.com & larry.king@permapipe.com; Website: www.permapipe.com
10,000 0.4 36 AUTO-THERM® Glass Syntactic Polyurethane (GSPU) for Flowlines & Jumpers H H H H H H H 0.07 0.5-4.0 0.4-2.0 0.35 51 H H H H H H H H H 160 10,000 10,000 H H H F, R, JT,JPR
10,000 0.4 37 AUTO-THERM® Glass Syntactic Polyurethane for Subsea Equipment H H 0.07 0.5-4.0 0.4-2.0 0.35 51 H H H H H H H H 10,000 5,600 H H H F, R, JT,JPR, M, T
5,000 10,000 0.4 38 AUTO-THERM® Glass Syntactic Polyurethane (GSPU) for Connector Shrouds H H 0.07 0.5-4.0 0.4-2.0 0.35 51 H H H H H H H H 10,000 5,000 H H H F, R, JT,JPR, M, T
575 1,000 0.15 XTRU-THERM® Mid to High Density Wet Insulation PU with PE Jacket H H H H H H H H 0.02 0.5-5.0 0.15 0.35 15 H H H H H H H H H 50 650 575 H H H F, R, JT
7,500 10,000 0.10 39 XTRU-THERM® Pipe-in-Pipe (PIP) Polyurethane Foam with PE Jacket H H H H H H H 0.015 0.5-4.0 0.1 0.35 4 H H H H H H H H 250 10,000 7500 H H H F, R, JT
100 0.03 40 XTRU-THERM® Cryogenic Pipeline - Mid Density PU Foam with PE Jacket H H 0.0125 0.5-6.0 0.03 0.35 4 H H H H H H H H 5 H F, R,JT
43 44 45 46 47 48 ROXAR Contact: Chris McPherson; 3300 Walnut Bend Lane, Houston, TX 77042; Phone: 713-334-2222; E-Mail: Chris. McPherson@Roxar.com; Website: www.roxar.com
7,800 10,000 41 Sand and Erosion Monitoring System H H H H H H H 10,000 7,800 H H H W, F, R, JT, T
6,500 10,000 42 FSM™ Corrosion / Erosion Monitoring System H H H H H H H H H H 10,000 6,500 H H H F, R, JT
7,800 10,000 43 Pressure / Temperature Monitoring H H H H H H H H H H 10,000 7,800 H H H W, F, R, JT, M, T
4,300 10,000 Flow Force H H H H H H H H H 10,000 4,300 H H H W, F, R, JT, M, T
9,000 10,000 44 Roxar Subsea MPFM H H H H H H H H H H H 10,000 9,000 H H H W, F, R, JT, M, T
9,600 45 Roxar Subsea Sand monitor / Pig detector H H H H H H H H H 10,000 9,600 H H H F, R, JT, JPR, M, T
SAIPEM Contact: Luc Poirson, Saipem SA; Bat. Energies, 1/7 avenue San Fernando, 78 884 St. Quentin en Yvelines Cedex, France; Phone: 33-161-37-6661; e-mail: luc.poirson@saipem.com; Christophe Candelier; Saipem SA; Bat. Energies, TEDE, 1/7 avenue San Fernando, 78884 St. Quentin en Yvelines, France; Phone: 33-161-37-8742; Fax: 33-161-37-8380; e-mail: christophe.candelier@saipem.com

49 50 51 52 53 54 4,000 10,000 0.16 46 Bundle Hybrid Offset Riser (BHOR) - Riser Tower H H H H H 0.007-0.07 0.25-2.0 0.16 0.24-0.35 6-18.8 H H H H H H H H 2.5 10,000 4,000 H H H R
3,400 10,000 0.36 Pipe in Pipe Single Hybrid Riser (PiP SHR) H H H 0.1-0.13 1-5 0.36 0.24-0.35 6-18.8 H H H H H H H 2 10,000 3,400 H H H R
3,400 10,000 0.18 PU foam insulated Pipe in Pipe (PUF PiP) H H H 0.012-0.024 0.5-6 0.18 0.32-0.34 H H H H H H H 24 10,000 3,400 H H H F, R
4,200 10,000 0.16 47 Aerogel insulated Pipe in Pipe H H H 0.007 0.25-2.0 0.16 0.24-0.35 6-18.8 H H H H H H H 6 10,000 4,200 H H H F, R
9,000 10,000 Gel insulating material H H H 0.084 0.41-0.43 49.9-53 H H H H H 10,000 H H F, R, JPR, JT
9,000 10,000 48 Gel ILS - Phase change insulating material H H H 0.11 0.5-0.55 49.9-54.5 H H H H H H 10,000 H H F, R, JPR, JT
9,000 10,000 0.32 Gel / Gel ILS production Flowline H H H 0.084-0.11 1-6 0.32 H H H H H H H 10,000 H H F, R
9,000 10,000 0.18 49 Gel production Bundle H H H 0.084 1-8 0.14-0.28 0.41-0.43 49.9-53 H H H H H H 10,000 H H F
4,600 10,000 0.47 Single Pipe Flowline & Riser H H H 0.1-0.13 4 0.47 0.33-0.48 43.6-56.2 H H H H H H H 33 10,000 4,600 H H F, R, JPR

55 56 57 58 59 60 SOCOTHERM Contact: Roberto Gozálvez; Ruta 9, km 52.3 Escobar, Buenos Aires, Argentina (1625); Phone: +54.3488.433.500; e-mail: roberto.gozalvez@socotherm.com.ar; Website: www.socotherm.com
8,200 10,000 1.9 50 Three Layer Polyethylene - Plastykote® H H H 0.13 0.06-0.5 > 1.90 H H H H H H H H H 35,000 10,000 8,200 H H H F, R, JT, JPR
8,200 10,000 1.9 51 Three Layer Polypropylene - Plastykote® H H H 0.2 0.06-0.5 > 1.90 H H H H H H H H H 5,000 10,000 8,200 H H H F, R, JT, JPR
6,600 10,000 1.9-0.40 52 Five Layer Solid Polypropylene - Wetisokote® H H H ATD H H H 0.13 0.5-6.0+ > 0.40 H H H H H H H H 60 10,000 6,600 H H H F, R, JT, JPR
1,800 2,000 1.9-0.35 53 Five Layer Polypropylene Foam - Wetisokote® H H H ATD H H H 0.095-0.101 0.5-6.0+ > 0.35 H H H H H H H H 130 2,000 1,800 H H H F, R, JT, JPR
8,200 10,000 1.9-0.35 54 Five Layer Syntactic Polypropylene - Wetisokote® H H H ATD H H H 0.081-0.092 0.5-6.0+ > 0.35 H H H H H H H H 184 10,000 8,200 H H H F, R, JT, JPR
330 650 0.70-0.10 55 High Density Polyurethane Foam - Thermakote® H H H ATD H H H 0.02-0.03 1.0-4.0 > 0.10 H H H H H H H H 60 650 330 H H H F, R, JT, JPR
5,000 10,000 0.36-0.10 56 Pipe in Pipe H H H ATD H H H > 0.018 Annular Gap 0.10-0.36 H H H 100 10,000 5,000 H H H F
TATA STEEL Contact: Derek Bish - Sales & Project Development Engineer; P.O. Box 101, Weldon Road, Corby, Northants, UK, NN175UA; Phone: 44-1536-404262; Fax: 44-1536-404004; E-Mail: derek.bish@tatasteel.com; Website: www.tatasteelenergy.com
61 62 63 64 65 66 8,200 10,000 0.05-0.25 Pipe-in-Pipe (PIP) - Lightweight Structural System H H H H H 0.012-0.023 0.1-0.25 H H H H H H H 8,200 H H H F, R
350 10,000 0.1-0.25 57 Pipe-in-Pipe (PIP) - Injected Polyurethane foam H H H H H 0.1-0.25 H H H H H H H H 350 350 H H H F, R
10,000 0.02-0.2 Pipe-in-Pipe (PIP) - Nanogel® / Polyurethane Foam Hybrid H H H H H 0.02-0.1 H H H H H H H H H H F, R
350 4,600 10,000 0.25-0.5 Hydrotherm™ H H H H 0.06 0.25-0.45 H H H H H H H H 45 4,600 350 H H H F, R
TRELLEBORG OFFSHORE (Incorporating Trelleborg Offshore US Inc., Trelleborg Offshore UK Ltd., Trelleborg Offshore Norway A.S) Contact: (USA) - Bob Kelly – VP of Sales, Phone +832-456-8300 E-Mail: offshore@trelleborg.com. (Europe) Ben Wait - Sales Manager - Thermal Insulation, Phone +44 (0) 1695 714332, E-Mail: Ben.wait@trelleborg.com. (Norway) Stein Hovde – Sales Manager, Phone +47 3223 2260, E-mail: stein.hovde@trelleborg.com, Website: www.trelleborg.com/offshore.
10,000+ >0.32 XTI-1003 (Solid Silicone Rubber) H H H H H H H 0.114 0.5-6.0 >0.32 67 H H H H H H H 11,300 H H H F, R, JT, JPR, M, T
720 >0.18 58 URATHERM™ - S250 (Syntactic Polyurethane) H H H H H 0.064 0.5-6.0 >0.18 0.373 45 H H H H H H H H >50(B) 720 720 H H H F, R, JT, JPR, M, T
6,560 >0.28 59 URATHERM™ - G3000 (Syntactic Polyurethane) H H H H H 0.096 0.5-8.0 >0.28 0.369 54 H H H H H H H H >2,200(B) 6,560 6,560 H H H F, R, JT, JPR, M, T
7,320 >0.27 60 TRIDENT™ (Syntactic Polyurethane) H H H H H 0.093 0.5-6.0 >0.27 0.343 53 H H H H H H H H 7,320 H H H F, R, JT, JPR, M, T
67 68
ABBREVIATIONS: F: Flowline PIP: Pipe-in-Pipe CONVERSION FACTORS: Length: 1 in. = 25.4 mm
10,000+ >0.32 61 URATHERM™ - P7000z (Polyurethane) H H H H H 0.12 0.5-8.0 >0.32 0.38 73 H H H H H H H H >25 23,000 23,000 H H H F, R, JT, JPR, M, T
R: Riser CAPEX: Capital Expenditure 1 ft. = 0.305 m
W: Well OPEX: Operating Expenditure 1 mile = 1,609 m Material used in sealed pipe in pipe systems (PIP) - not water depth dependant in this application >0.033 URATHERM™ - PIP (Foamed Polyurethane for Pipe In Pipe systems) H H H 0.014 0.5-6.0 >0.033 H H H H H H H H >20 N/A N/A H H H F, R
T: Tree INSTEX: Installation Expenditure 5,085 6,560 >0.16 62 ULTRATHERM™ - 1500 (Syntactic Foam) H H H H H 0.06 0.5-6.0 >0.16 0.265 39 H H H H H H H H >200(B) 6,560 5,085 H H H F, R, JT, JPR, M, T
JPR: Jumper FIELD PROVEN: Previously Used in Field Thermal Conductivity: 1 Btu/(hr-ft -°F) = 1.73 W/(m-K)
4,265 8,200 >0.19 63 ULTRATHERM™ - 2000 (Syntactic Foam) H H H H H 0.063 0.5-6.0 >0.19 0.249 41 H H H H H H H H 8,200 4,265 H H H F, R, JT, JPR, M, T
JT: Joint PROTOTYPE: Passed Onshore Test Program
M: Manifold CONCEPTUAL: Design Only U-Value (Heat Transfer Coefficient): 1 Btu/(hr-ft2-°F) = 5.67 W/(m2-K) 10,000+ >0.23 ECCOTHERM® 7000 H H H H 0.074 0.5-6.0 >0.23 0.239 43 H H H H H H H H >1 10,000 H H H F, R, JT, JPR, M, T
HP/HT: High Pressure / High Temperature U-VALUE: Overall Heat Transfer Coefficient 1,000 >0.1 64 ECCOTHERM® PT 1000 H H H H 0.092 0.138-0.394 per layer >1 0.435 44.0 H H H H H H H H >50 1,000 H H H F, R
PL: Pipeline ATD: According to Design 2,000 3,000 >0.1 65 ECCOTHERM® PT 3000 H H H H 0.092 0.138-0.394 per layer >1 0.373 43.0 H H H H H H H H >50 3,000 2,000 H H H F, R
OD: Outer Diameter MIN: Minimized
4,000 7,000 >0.1 ECCOTHERM® PT 7000C Blue H H H H 0.098 0.138-0.394 per layer >1 0.289 47.0 H H H H H H H H >100 7,000 4,000 H H H F, R
NOTES: Information Accuracy: Every attempt has been made to locate all companies, their products and services, which provide
POSTER
©2012 Offshore

8,000 >0.21 ECCOTHERM® FC-39 (Syntactic Epoxy) H H H H 0.069 1.0-6.0 >0.21 0.296 39 H H H H H H H H H 8,000 8,000 H H H F, R, JT, JPR, M, T

97
A. Specific heat and density of materials are not provided. non-chemical flow assurance solutions. No company was intentionally excluded from the survey. We make no guarantee
These characteristics have a strong influence on cool down time. that this list is all inclusive. We have been careful to summarize the characteristics and experience of each company 5,000 9,000 >0.26 66 VIKOTHERM - HISC protection H H H H H H H 0.075 0.15-6.0 >0.3 H H H H H H H H H H >10 6,560 5,000 H H H W,F,R,JPR,JT,M,T
as well as possible, by acting as a neutral party and integrator of information. We have collected information from each
B. Although extremely important to flow assurance, pigging issues 5,000 9,000 >0.13 67 VIKOTHERM - High temp resistant H H H H H H H 0.075 0.15-6.0 >0.3 H H H H H H H H H H >10 6,560 5,000 H H H W,F,R,JPR,JT,M,T
company, phone interviews and personal interviews. Neither McDermott Subsea Engineering nor Offshore Magazine
have not been included in these calculations. 5,000 9,000 >0.13
guarantees or assumes any responsibility or liability for any reliance on the information presented. 68 VIKOTHERM - Standard H H H H H H H 0.075 0.15-6.0 >0.3 H H H H H H H H H H >10 6,560 5,000 H H H W,F,R,JPR,JT,M,T

2013 SUBSEA TIEBACK FORUM & EXHIBITION OCEANS COVER 285 BILLION BARRELS OF THE WORLD’S KNOWN OIL RESERVES – OFFSHORE COVERS THEM ALL.
11700 Katy Freeway, Suite 1200
Houston, Texas 77079 - USA
moody gardens hotel & convention center | galveston, tx Tel: +1 281 249 3300
november 6 - 8, 2012

World Trends and Technology


C O N F E R E N C E & E X H I B I T I O N
www.genesisoilandgas.com

FEBRUARY 5 – 7, 2013
MOODY GARDENS CONVENTION CENTER
GALVESTON, TEXAS, USA
Flow Assurance & Operability

for Offshore Oil and Gas Operations


WWW.TOPSIDESEVENT.COM

MARCH 5 – 7, 2013
Henry B. Gonzalez Convention Center • San Antonio, Texas USA
www.SubseaTiebackForum.com
www.deepwateroperations.com
Where it all comes TOGETHER .
SSTBdoTOP_petro_120315 1 3/15/12 4:15 PM
Techn_OSmaps_1204 1 2/24/12 1:58 PM

0412FlowAssurance-Poster032112.indd 1 3/21/12 2:23 PM