This bulletin is issued to inform users of the current list of approved cleaning agents and to draw
attention to health and safety recommendations for handling these cleaners.
CLEANER SUPPLIER
ZOK 27 AIRWORTHY LIMITED
R-MC G21 IVAR RIVENAES LIMITED OR
R-MC G2 1 C/6 SERMATECH INTERNATIONAL INC.
The effectiveness of cleaning agents can only be established by extended use at various sites.
The following cleaners which we have analysed may also be suitable for use in our gas turbines.
However, to date RGT does NOT have field experience on these cleaners.
CLEANER SUPPLIER
CASTROLSOLVEXICD177 BURMAH-CASTROL (UK) LTD
ARDROX 6345 ARDROX PYRENE LTD
CLEANER SUPPLIER
ROCHEM FYREWASH ROCHEM R-O DESALINATION LTD
WARNING: THIS CLEANER IS FLAMMABLE. THE SUPPLIERS HEALTH AND SAFETY INSTRUCTIONS
MUST BE STRICTLY ADHERED TO.
INJECTION RATE
The nominal injection rate of cleaning mixture for all applications is
1-1.5 galls/minute (4.5-6.8 litres/minute) maximum.
INJECTION QUANTITY
The quantity of cleaning mixture injected for each normal wash should be 6 gallons (27 litres).
DILUTION RATE
The dilution rate by volume for each listed cleaner is as follows:
NOTES
1) The above dilution rates are only applicable at ambient temperatures above 5°C. For ambient
temperatures below 5°C reference should be made to the chart on page 4.
2) Only DEMINERALISED WATER which meets the following conditions should be used for dilution
and rinsing:
YOUR ATTENTION IS DRAWN TO THE LISTED SUPPLIERS CURRENT HEALTH AND SAFETY DATA
SHEETS IN RESPECT OF THEIR CLEANING AGENTS, COPIES OF WHICH ARE ATTACHED TO THIS
BULLETIN.
Users should consult suppliers for any further information and updating which may be required.
ANTI-FREEZE AGENTS
When liquid washing during cold weather it is necessary to add anti-freeze to the demineralised water
to prevent the formation of ice in the compressor.
The recommended anti-freeze is METHANOL (METHYL ALCOHOL) which should conform to BS506
PART 1: 1966.
The recommended quantity of anti-freeze which must be added for various temperature conditions is
shown in the chart on page 4.
ANTI-FREEZE QUANTITIES
Each 6 gallons (27 litres) charge of washing fluid should be mixed in the following proportions of
Cleaner/Water/Anti-freeze: