Вы находитесь на странице: 1из 9

PASO 1 - ACTIVIDAD COLABORATIVA 1

5.1.3.6 PACKET TRACER – CONFIGURING ROUTER-ON-A-STICK INTER-


VLAN ROUTING

EDWIN VICENTE ZAPATA CARDONA


CÓDIGO: 1118286621

GRUPO
2150507_11

TUTOR
MARTHA FABIOLA CONTRERAS

UNIVERSIDAD NACIONAL ABIERTA Y A DISTANCIA UNAD


ESCUELA DE CIENCIAS BASICAS, TECNOLOGIA E INGENIERIA
PROGRAMA INGENIERIA ELECTRÓNICA
PRINCIPIOS DE ENRUTAMIENTO 2150507A-471
CEAD PALMIRA
Packet Tracer – Configuring Router-on-a-Stick Inter-VLAN
Routing
Addressing Table

Device Interface IPv4 Address Subnet Mask Default Gateway

G0/0.10 172.17.10.1 255.255.255.0 N/A


R1
G0/0.30 172.17.30.1 255.255.255.0 N/A
PC1 NIC 172.17.10.10 255.255.255.0 172.17.10.1
PC2 NIC 172.17.30.10 255.255.255.0 172.17.30.1

Objectives
Part 1: Test Connectivity without Inter-VLAN Routing
Part 2: Add VLANs to a Switch
Part 3: Configure Subinterfaces
Part 4: Test Connectivity with Inter-VLAN Routing

Scenario
In this activity, you will check for connectivity prior to implementing inter-VLAN routing. You will
then configure VLANs and inter-VLAN routing. Finally, you will enable trunking and verify
connectivity between VLANs.

Part 1: Test Connectivity Without Inter-VLAN Routing


Step 1: Ping between PC1 and PC3.
Wait for switch convergence or click Fast Forward Time a few times. When the link lights are
green for PC1 and PC3, ping between PC1 and PC3. Because the two PCs are on separate
networks and R1 is not configured, the ping fails.
Step 2: Switch to Simulation mode to monitor pings.
a. Switch to Simulation mode by clicking the Simulation tab or pressing Shift+S.
b. Click Capture/Forward to see the steps the ping takes between PC1 and PC3. Notice how
the ping never leaves PC1. What process failed and why?

Part 2: Add VLANs to a Switch


Step 1: Create VLANs on S1.
Return to Realtime mode and create VLAN 10 and VLAN 30 on S1.

Step 2: Assign VLANs to ports.


a. Configure interface F0/6 and F0/11 as access ports and assign VLANs.
 Assign PC1 to VLAN 10.
 Assign PC3 to VLAN 30.
b. Issue the show vlan brief command to verify VLAN configuration.
S1# show vlan brief

VLAN Name Status Ports


---- -------------------------------- --------- ---------------------------
----
1 default active Fa0/1, Fa0/2, Fa0/3, Fa0/4
Fa0/5, Fa0/7, Fa0/8, Fa0/9
Fa0/10, Fa0/12, Fa0/13,
Fa0/14
Fa0/15, Fa0/16, Fa0/17,
Fa0/18
Fa0/19, Fa0/20, Fa0/21,
Fa0/22
Fa0/23, Fa0/24, Gig0/1,
Gig0/2
10 VLAN0010 active Fa0/11
30 VLAN0030 active Fa0/6
1002 fddi-default active
1003 token-ring-default active
1004 fddinet-default active
1005 trnet-default active

Step 3: Test connectivity between PC1 and PC3.


From PC1, ping PC3. The pings should still fail. Why were the pings unsuccessful?
Part 3: Configure Subinterfaces
Step 1: Configure subinterfaces on R1 using the 802.1Q encapsulation.
a. Create the subinterface G0/0.10.
 Set the encapsulation type to 802.1Q and assign VLAN 10 to the subinterface.
 Refer to the Address Table and assign the correct IP address to the subinterface.
b. Repeat for the G0/0.30 subinterface.

Step 2: Verify Configuration.


a. Use the show ip interface brief command to verify subinterface configuration. Both
subinterfaces are down. Subinterfaces are virtual interfaces that are associated with a
physical interface. Therefore, in order to enable subinterfaces, you must enable the
physical interface that they are associated with.
b. Enable the G0/0 interface. Verify that the subinterfaces are now active.
Part 4: Test Connectivity with Inter-VLAN Routing
Step 1: Ping between PC1 and PC3.
From PC1, ping PC3. The pings should still fail.

Step 2: Enable trunking.


a. On S1, issue the show vlan command. What VLAN is G0/1 assigned to?
b. Because the router was configured with multiple subinterfaces assigned to different VLANs,
the switch port connecting to the router must be configured as a trunk. Enable trunking on
interface G0/1.
c. How can you determine that the interface is a trunk port using the show vlan command?
d. Issue the show interface trunk command to verify the interface is configured as a trunk.
Step 3: Switch to Simulation mode to monitor pings.
a. Switch to Simulation mode by clicking the Simulation tab or pressing Shift+S.
b. Click Capture/Forward to see the steps the ping takes between PC1 and PC3.
c. You should see ARP requests and replies between S1 and R1. Then ARP requests and
replies between R1 and S3. Then PC1 can encapsulate an ICMP echo request with the
proper data-link layer information and R1 will route the request to PC3.
Note: After the ARP process finishes, you may need to click Reset Simulation to see the
ICMP process complete.