Вы находитесь на странице: 1из 8

© Siemens AG 2010

Flow Measurement
SITRANS F US Clamp-on
Accessories/Spare parts

■ Accessories/Spare parts for clamp-on ultrasonic flowmeters


Description Order No. Description Order No.
Universal Portable Sensors D) 7ME3951-... Mounting Frames D) 7ME3960-...
Selected generally for portable These items are useful in sim-
systems where a wide variety plifying sensor installation.
of pipes are to be measured. They are strapped to the pipe
Since they are selected based first then the sensors are
on diameter only, a wide range installed, making the installa-
of pipe sizes and materials can tion less cumbersome and
be covered with a minimum more precise. They also enable
number of sensors. These can easy repeated mounting of the
also be selected as a cost sav- sensors assuring conformation
ings on applications where to the original sensor position-
standard accuracy is sufficient. ing. They may be left in place
at each measurement location
High Precision Sensors D) 7ME3950-...
where periodic flow surveys
Selected generally for dedi- are conducted to simplify sub-
cated meters since the need to sequent installations and
cover a range of pipes is not a ensure repeatable results.
4 requirement. They provide the
highest accuracy achievable Spacer Bars D) 7ME3960-...
by the meters and therefore Sensors are required to be
should be selected whenever mounted at a set distance from
higher accuracy/repeatability each other as determined by
is required. They are only pipe size and medium being
applicable to steel pipes but measured. The spacer bar sim-
no other metals, and are plifies this requirement by elim-
selected solely by wall thick- inating the need to undertake a
ness. precise dimensional measure-
ment. The flowmeter will spec-
High Temperature Sensors D) 7ME3950-...
ify a specific spacing index
Are selected whenever pipe which is easily accommodated
temperature will exceed 250 ºF with the marked indices on the
(120 ºC) up to a maximum of bar.
450 ºF (232 ºC). They are uni-
versal type and can therefore Clamp-On RTD's D) 7ME3950-...
be used on any pipe material 1000 Ω platinum RTD's for use
and are selected by pipe diam- where temperature is required.
eter. Used with Energy Meters to
record supply/return tempera-
Weld Seal Mount D) 7ME3960-...
ture. For this purpose precision
These provide the most secure matched pairs (to 0.02 ºC) are
and strongest mounting of the supplied. Single RTD's are also
flow sensors. They are gener- used with FUH and FUG
ally selected for "High End" meters to enable live calcula-
meter types where maximum tions of "Liquident" and Stan-
performance criteria applies. dard Volume Correction.
They accommodate high preci-
sion sensors designed to Insert RTD's D) 7ME3950-...
mount inside these enclo- Are identical to clamp-on
sures. May be welded to the RTD's as described above
pipe if so desired by the cus- except that they are inserted
tomer. They come in 2-piece or into the pipe (In a Thermo-
1-piece configurations well). They provide more pre-
depending upon the applica- cise and quicker responding
tion pipe size and type (Liq- temperature measurement.
uid/Gas). They are selected when pre-
cise temperature measure-
Mounting tracks D) 7ME3960-...
ment of the actual liquid or gas
Typically used on smaller pipes is required as opposed to pipe
for easier and more stable "skin temperature". Since they
mounting for dedicated univer- project into the pipe they can-
sal style sensor size A or B, not be used in pipeline that
also available for dedicated undergo periodic "pigging".
high precision sensor size A or
B. Standard Cable (Flow Sen- D) 7ME3960-...
sor or RTD)
Selected for general purpose
installations where no special
application requirements exist.

Submersible Cable (Flow D) 7ME3960-...


Sensor)
Polyethylene jacketed, for loca-
tions that experience periodi-
cal or continual submersion of
the flow sensors.

4/354 Siemens FI01 · 2011


© Siemens AG 2010

Flow Measurement
SITRANS F US Clamp-on
Accessories/Spare parts
Description Order No. Description Order No.
Plenum Cable (Flow Sensor D) 7ME3960-... Test Block D) 7ME3960-...
or RTD) Used for checking operation of
For temperatures above a meter and sensors prior to a
180 ºF. Teflon jacketed to with- field installation, or as a trou-
stand high temperatures, is bleshooting tool. Selected by
used when high temp sensors sensor size, each block
are specified. accommodates 2 sensor sizes.
Available only for universal
Armored Cable (Flow Sensor) D) 7ME3960-... sensors.
Double shielded cable,
Termination Kit (Flow Sen- D) 7ME3960-...
selected when cable will not be
sor or RTD)
installed in conduit between
meter and sensors. Provides the connectors, labels
and shrink tubing or other
associated hardware to com-
plete the termination of a spe-
Temperature sensor cable D) 7ME3960-... cific cable type. These can be
Cable to connect field installed provided in cases where users
RTD to flow meter, available in will be purchasing bulk cable
Teflon wrapped, plenum or
submersible grade. Typically
directly and cutting to length at
their site, or when existing 4
used for FUE, FUH and FUG cable length is to be altered.
series meters where a temper- Selected by cable type.
ature sensor is employed.
Straps D) 7ME3960-...
Used to fasten sensors or
mounting frames to pipe for
dedicated meter installations.
Stainless steel construction for
corrosion resistance.

Chains (EZ clamps) D) 7ME3960-...


Used to fasten portable sen-
sors or mounting frames to
pipe. Thumbscrews eliminate
need for hand tools when
mounting sensors, and allow
for easy on/off operations.
Ultrasonic Couplant D) 7ME3960-...
Fills any voids between sensor
emitting surface and pipe wall
to allow maximum energy
transfer between sensor and
pipe. Several different types of
couplants are employed as
determined by the application
conditions and type of installa-
tion (Temporary or permanent).

Dry Couplant D) 7ME3960-...


The dry coupling pad is
intended for use in any liquid,
clamp-on transit time or Dop-
pler applications that require a
more durable coupling material.
Installation is easy by simply
placing one strip of material
between sensor and pipe. Not
intended for clamp-on gas
where damping material is
used. The temperature range is
-34 to +200 °C (-30 to +392 °F).
Damping Material D) 7ME3960-...
Used with gas meters, and
required as part of their sensor
installation. This material
absorbs excess ultrasonic
energy from the pipe wall to
enable the meter to detect and
operate with low amplitude
sensor signals normally associ-
ated with Clamp-on Gas appli-
cations.

Siemens FI01 · 2011 4/355


© Siemens AG 2010

Flow Measurement
SITRANS F US Clamp-on
Accessories/Spare parts
Selection and Ordering data Order No.
Spare parts (System)
SITRANS FUS clamp-on 7M E 3 9 4 0 - 7 7 7 7 7
Power supplies, batteries and chargers
Power supply 90 ... 240 V AC
• for IP65 (NEMA 4X) or IP66 (NEMA 7 Wall D) 0 PA0 0
mount)
• for IP65 (NEMA 7) Compact D) 2 PA0 0
Power supply 9 ... 36 V DC
• for IP65 (NEMA 4X) or IP66 (NEMA7 Wall K) 0 PB0 0
mount)
• negative ground for NEMA 7 Compact D) 2PJ00
• positive ground for NEMA 7 Compact D) 2 PK0 0
Portable meter batteries and accessories

4 • Internal battery (Portable meters only)


IP67 Portable meter charger
D) 3PP0 0

• Type A for Europe (CEE7/7) D) 3 PC0 0


• Type C for Australia (AS3112) D) 3 PD0 0
• Type D for UK (BS1363) D) 3PE0 0
• Type J for Japan (JIS8303) D) 3PF00
• Type K for US (NEMA 5-15P) D) 3 PG0 0
• Type L for Switzerland (SEV1011) D) 3 PH0 0
IP40 Portable meter charger
• Type A for Europe (CEE7/7) D) 4 PC0 0
• Type C for Australia (AS3112) D) 4 PD0 0
• Type D for UK (BS1363) D) 4PE0 0
• Type J for Japan (JIS8303) D) 4PF00
• Type K for US (NEMA 5-15P) D) 4 PG0 0
• Type L for Switzerland (SEV1011) D) 4 PH0 0
MODBUS system computer modules
MODBUS converter module D) CQO-1015N-5M
Mounting kit (type 1) for MODBUS converter D) CQO-1015N-5M-MK1
module

Mounting kit (type 2) for MODBUS converter D) CQO-1015N-5M-MK2


module
Mounting kit (type 3) for MODBUS converter D) CQO-1015N-5M-MK3
module
Field configuration kit with manual, for MOD- D) CQO-1015N-5M-FK1
BUS converter module

Pipe mounting brackets


2 inch pipe mounting bracket for IP65 (NEMA 7) D) CQO-1012XMB-1
2 inch pipe mounting bracket for IP65 D) CQO-1012NMB-1
(NEMA 4X)
D) Subject to export regulations AL: N, ECCN: EAR99H.
K) Subject to export regulations AL: N, ECCN: 5A991X.

4/356 Siemens FI01 · 2011


© Siemens AG 2010

Flow Measurement
SITRANS F US Clamp-on
Accessories/Spare parts
Selection and Ordering data Order No. Selection and Ordering data Order No.
Spare parts (Sensors) Spare parts (Sensors)
SITRANS F US clamp-on SITRANS F US clamp-on
Meter type Meter type
Dedicated (FUS1010, FUG1010, FUH1010, D) 7M E 3 9 5 0 - 7 7 7 7 7 Dedicated (FUS1010, FUG1010, FUH1010, D) 7M E 3 9 5 0 - 7 7 7 7 7
FUE1010) FUE1010)

Portable (FUP1010 or FUE1010) D) 7M E 3 9 5 1 - 0 7 7 7 7 Portable (FUP1010 or FUE1010) D) 7M E 3 9 5 1 - 0 7 7 7 7


Approvals High temperature universal liquid sensors
UL, ULc, CE (Portable only) 0 Note: not available with INMETRO approval
FM/CSA hazardous (classified) locations 1 High temp. sensor size 1 for up to 230 °C LA1 0
(12.7 to 100 mm diam.)
ATEX Ex II 1G Ex ia IIC T5 (not for RTDs) 2
High temp. sensor size 2 for up to 230 °C LA2 0
INMETRO (not for (RTDs) 3 (30 to 200 mm diam.)
Spare sensor code High temp. sensor size 3 for up to 230 °C LA3 0
For liquid flow sensors pipe ranges please (150 to 600 diam.)
refer to sensor selection chart in the FUS1010
section
High temp. sensor size 4 for up to 230 °C
(400 to 1200 diam.)
LA4 0 4
Liquid flow sensors for use with mounting For gas flow sensors pipe ranges please refer
frames or tracks (including portable) to sensor selection chart in the FUG1010 sec-
A2 universal LB0 0 tion

B3 universal LC0 0 High precision gas flow sensors for use with
mounting frames or tracks
C3 universal LD0 0
B1H (high precision) GK 0 0
D3 universal LE0 0
B2H (high precision) GL 0 0
E2 universal LF00
B3H (high precision) GT 0 0
A1H (high precision) LG0 0
C1H (high precision) GM 0 0
A2H (high precision) LH0 0
C2H (high precision) GN 0 0
A3H (high precision) LJ00
D1H (high precision) GP 0 0
B1H (high precision) LK0 0
D2H (high precision) GQ 0 0
B2H (high precision) LL00
D3H (high precision) GU 0 0
B3H (high precision) LT00
D4H (high precision) GR 0 0
C1H (high precision) LM0 0
High precision gas sensor for weld seal enclo-
C2H (high precision) LN0 0 sures
D1H (high precision) LP0 0 B1H (high precision, weld seal) HK 0 0
D2H (high precision) LQ0 0 B2H (high precision, weld seal) HL 0 0
D3H (high precision) LU0 0 B3H (high precision, weld seal) HT 0 0
D4H (high precision) LR0 0 C1H (high precision, weld seal) HM 0 0
Doppler LS0 0 C2H (high precision, weld seal) HN 0 0
High precision liquid sensor for weld seal enclo- D1H (high precision, weld seal) HP 0 0
sures
D2H (high precision, weld seal) HQ 0 0
B1H (high precision, weld seal) SK 0 0
D3H (high precision, weld seal) HU 0 0
B2H (high precision, weld seal) SL0 0
D4H (high precision, weld seal) HR 0 0
B3H (high precision, weld seal) ST0 0
D) Subject to export regulations AL: N, ECCN: EAR99H
C1H (high precision, weld seal) SM 0 0
C2H (high precision, weld seal) SN 0 0
D1H (high precision, weld seal) SP 0 0
D2H (high precision, weld seal) SQ 0 0
D3H (high precision, weld seal) SU 0 0
D4H (high precision, weld seal) SR 0 0

Siemens FI01 · 2011 4/357


© Siemens AG 2010

Flow Measurement
SITRANS F US Clamp-on
Accessories/Spare parts
Selection and Ordering data Order No. Selection and Ordering data Order No.
Spare parts (Sensors) Spare parts (Miscellaneous)
SITRANS F US clamp-on SITRANS F US clamp-on D) 7M E 3 9 6 0 - 7 7 7 7 7
Meter type Meter design
Dedicated (FUS1010, FUG1010, FUH1010, D) 7M E 3 9 5 0 - 7 7 7 7 7 IP65 (NEMA 4X) or IP66 (NEMA 7 wall mount) 0
FUE1010)
IP65 (NEMA 7) Compact 2
Portable (FUP1010 or FUE1010) D) 7M E 3 9 5 1 - 0 7 7 7 7 IP67 Weather proof portable 3
Standard RTD sensors (not for energy sys- IP40 (NEMA 1) Portable 4
tems)
Dedicated sensor mounting hardware
Standard clamp-on RTD 1TA0 0
Sensor mounting tracks (aluminium with
Submersible clamp-on RTD (not for portable) 1TB0 0 mounting straps) for pipes < 125 mm (5 inch)
Insertion style RTD pair (size 1), 1TJ00 • Universal sensor size A or B 0 MA 0 0
140 mm
(5.5 inch) • High precision sensor size A or B 0 MB 0 0
Insertion style RTD pair (size 2), 1TJ01 Sensor mounting frames for
4 216 mm
(8.5 inch)
• Universal sensor size B
(for pipes >125 mm (5 inch)
D) CQO-1012FN-PB

Insertion style RTD pair (size 3), 1TJ02 • Universal sensor size C 0 MC 0 0
292 mm
(11.5 inch) • Universal sensor size D 0 MC 0 1
Insertion style RTD pair (size 4), 1TJ03 • Universal sensor size E 0 MC 0 2
368 mm
• High precision sensor size B (for pipes D) CQO-1012FNH-PB
(14.5 inch)
>125 mm (5 inch)
Standard for energy system (matched pair)
• High precision sensor size C 0 MD 0 0
Standard clamp-on RTD 1TA1 0
• High precision sensor size D 0 MD 0 1
Insertion style RTD pair (size 1) for Energy 1TJ10
Mounting straps for mounting frames (slotted
system FUE1010, 140 mm (5.5 inch)
stainless steel)
Insertion style RTD pair (size 2) for Energy 1TJ11
• For pipes from DN 50 to DN 150 0 SM 0 0
system FUE1010, 216 mm (8.5 inch)
Insertion style RTD pair (size 3) for Energy 1TJ12 • For pipes from DN 50 to DN 300 0 SM 1 0
system FUE1010, 292 mm (11.5 inch) • For pipes from DN 300 to DN 600 0 SM 2 0
Insertion style RTD pair (size 4) for Energy 1TJ13 • For pipes from DN 600 to DN 1200 0 SM 3 0
system FUE1010, 368 mm (14.5 inch)
• For pipes from DN 1200 to DN 1500 0 SM 4 0
1)
Supplied spacer bar supports pipes up to 750 mm (30 inches). For pipes
larger than 750 mm (30 inches) purchase also, spare part • For pipes from DN 1500 to DN 2100 0 SM 5 0
7ME3960-0MS40 (1012-BN-4) • For pipes from DN 2100 to DN 3000 0 SM 6 0
D) Subject to export regulations AL: N, ECCN: EAR99H. Spacer bars (for indexing sensors on pipe)
• Spacer bars for pipes to 200 mm/8 inch 0 MS 1 0
(liquid), 600 mm / 24 inch (gas)
• Spacer bars for pipes to 500 mm/20 inch 0 MS 2 0
(liquid), DN 1200 / 48 inch (gas)
• Spacer bars for pipes to 800 mm/32 inch 0 MS 3 0
(liquid)
• Spacer bars for pipes to 1200 mm/48 inch 0 MS 4 0
(liquid)
Only use in conjunction with 7ME3960-0MS30
Weld seal mounting enclosures for liquid and
gas sensors
• Single enclosure for size B high precision 0 WS 1 0
• Single enclosure for size C high precision 0 WS 2 0
• Single enclosure for size D high precision 0 WS 3 0
• Single enclosure for size E universal 0 WS 4 0
• Dual enclosure for size C high precision 0 WD 2 0
• Dual enclosure for size D high precision 0 WD 3 0
• Dual enclosure for size E universal 0 WD 4 0

4/358 Siemens FI01 · 2011


© Siemens AG 2010

Flow Measurement
SITRANS F US Clamp-on
Accessories/Spare parts
Selection and Ordering data Order No. Selection and Ordering data Order No.
Spare parts (Miscellaneous) Spare parts (Miscellaneous)
SITRANS F US clamp-on D) 7M E 3 9 6 0 - 7 7 7 7 7 SITRANS F US clamp-on D) 7M E 3 9 6 0 - 7 7 7 7 7
Stainless steel straps for weld seal enclosure RTD mounting hardware for portable system 3 MR 0 0
mounting
Sensor connector adaptors
• Mounting strap for pipe diameter to 300 mm 0 SM0 1
• "F" connector to BNC adapter (order 2 per D) CQO-1012NFPA
(13 inch)
sensor set)
• Mounting strap for pipe diameter to 600 mm 0 SM1 1
(24 inch) SITRANS FST020 Sensor trackmounts

• Mounting strap for pipe diameter to 1200 mm 0 SM2 1 • Single enclosure mounting track for "A" size CQO-1022A1R
(48 inch) Xdcr pair, Reflect

• Mounting strap for pipe diameter to 1500 mm 0 SM3 1 • Single enclosure mounting track for "B" size CQO-1022B1R
(60 inch) Xdcr pair, Reflect

• Mounting strap for pipe diameter to 2130 mm 0 SM4 1 • Dual enclosure mounting track for "B" size CQO-1022B2R
(84 inch) Xdcr pair, Reflect/Direct

• Mounting strap for pipe diameter to 3050 mm 0 SM5 1 • Single enclosure mounting track for "C" size CQO-1022C1R
Xdcr pair, Reflect
(120 inch)
Stainless mounting tracks for high temp 991 • Dual enclosure mounting track for "C" size CQO-1022C2R
4
sensors Xdcr pair, Reflect/Direct

• Size 1 high temp sensor pair D) CQO-992MTNHMSH-1 • Dual enclosure mounting track for "D" size CQO-1022D2R
Xdcr pair, Reflect/Direct
• Size 2 high temp sensor pair D) CQO-992MTNHMSH-2
D) Subject to export regulations AL: N, ECCN: EAR99H.
• Size 3 high temp sensor pair D) CQO-992MTNHMSH-3
• Size 4 high temp sensor pair D) CQO-992MTNHMSH-4
Clamp-on RTD mounting hardware for dedi-
cated systems
• RTD mounting hardware for dedicated 0 MR 0 0
system: 152 to 610 mm (6 to 24 inch)
• RTD mounting hardware for dedicated 0 MR 0 1
system: 12.7 to 50.8 mm (0.5 to 2 inch)
• RTD mounting hardware for dedicated 0 MR 0 2
system: 31.8 to 203.2 mm (1.25 to 8 inch)
• RTD mounting hardware for dedicated 0 MR 0 4
system: 508 to 1219 mm (20 to 48 inch)
• Junction box for clamp on RTD’s D) CQO-992ECJ
Portable sensor mounting hardware
Sensor mounting tracks for portable sensors
(aluminum with mounting chains) for pipes <
125 mm (5 inch) for
• Universal sensor size A or B 3 MA 0 0
• High precision sensor size A or B 3MB 0 0
Sensor mounting frames
• Universal sensor size B (for pipes >125 mm D) CQO-1012FP-PB
(5 inch)
• Universal sensor size C 3 MC 0 0
• Universal sensor size D 3 MC 0 1
• Universal sensor size E 3 MC 0 2
• High precision sensor size B (for pipes D) CQO-1012FPH-PB
> 125 mm (5 inch)
• High precision sensor size C 3 MD 0 0
• High precision sensor size D 3 MD 0 1
Spacer bar (for indexing portable sensors 3 MS 0 0
Mounting chain and EZ clamp hardware
• EZ clamp hardware set for DN 25 to D) CQO-1012Z-1
DN 600 (1 to 24 inch); handles all trans-
ducers except "D" size HP and "E" size univ.
• EZ clamp hardware set for DN 25 to D) CQO-1012Z-2
DN 600 (1 to 24 inch) for "D" size HP
and "E" size universal
• Mounting chain for portable sensors: 3 CM 1 0
4 x 760 mm lengths
• Mounting chain for portable sensors: 3 CM 2 0
2 x 760 mm and 2 x 1500 mm lengths

Siemens FI01 · 2011 4/359


© Siemens AG 2010

Flow Measurement
SITRANS F US Clamp-on
Accessories/Spare parts
Selection and Ordering data Order No. Selection and Ordering data Order No.
Spare parts (Miscellaneous) Spare parts (Miscellaneous)
SITRANS F US clamp-on D) 7M E 3 9 6 0 - 7 7 7 7 7 SITRANS F US clamp-on D) 7M E 3 9 6 0 - 7 7 7 7 7
Insert RTD Thermowells Ultrasonic couplants
• Thermowell std. duty uninsulated pipe 140 D) CQO-1012TW-1 • Temporary water based for portable systems: 0 UC 1 0
mm (5.5 inch) 350 ml (12 oz): -34 ... +38 °C (-30 ... +100 °F)
• Thermowell std. duty uninsulated pipe 216 D) CQO-1012TW-2 • Permanent synthetic polymer based: 90 ml 0 UC 2 0
mm (8.5 inch) (3 oz) -40 ... +190 °C (-40 ... +375 °F)
• Thermowell std. duty uninsulated pipe 292 D) CQO-1012TW-3 • Permanent high temp fluoroether: 12 ml 0 UC 3 0
mm (11.5 inch) (0.4 oz): -40 ... +230 °C (-40 ... +450 °F)
• Thermowell std. duty with lagging 140 mm D) CQO-1012TW-1L • Permanent high temp fluoroether: 163 ml 0 UC 5 0
(5.5 inch) (5.5 oz): -40 ... +230 °C (-40 ... +450 °F)
• Thermowell std. duty with lagging 216 mm D) CQO-1012TW-2L • Permanent vulcanizing silicone rubber D) CQO-CC112
(8.5 inch) couplant: 90 ml (3 oz): -40 …+120 °C
(-40 …+250 °F)
• Thermowell std. duty with lagging 292 mm D) CQO-1012TW-3L
(11.5 inch) • Permanent high temp silicone grease: 12 ml D) CQO-CC117
4 Sensor cables for
(Use „Sensor cable selection chart“ to com-
(0.4 oz): -40 ... +230 °C (-40 ... +450 °F)
• Permanent high temp silicone grease: 150 ml D) CQO-CC117A
plete Order No. with ##) (5 oz): -40 ... +230 °C (-40 ... +450 °F)
• IP65 (NEMA 4X) or IP 66 (NEMA 7 wall mount) 0 CK # # • Couplant for submersible sensor applications D) CQO-CC120
• IP65 (NEMA 7) Compact 2 CK # # • Dry coupling pads (qty of 10): 0 UC 4 0
-34 to +200 °C (-30 to +392 °F)
• IP67 Weather proof portable 3 CK # #
Pipe damping films for FUG gas systems
• IP40 (NEMA 1) Energy portable 4 CK # #
• B1, B2, B3, C1 and C2 sensors 0 DM 1 0
RTD cables for
(Use „Sensor cable selection chart“ to com- • D1 and D3 sensors 0 DM 2 0
plete Order No. with ##)
• D2 sensor 0 DM 3 0
• All dedicated systems 0 CR # #
• D4 sensor 0 DM 4 0
• IP67 Weather proof portable 3 CR # #
Serial RS232 Cables and I/O Adapters
• IP40 (NEMA 1) Energy portable 4 CR # #
• RS232 Cable for all dedicated meters 0CS 0 0
Dedicated cable termination kits
• RS232 Cable for IP66 Weather proof 3CS 0 0
• Standard, plenum and armored sensor cable 0CT0 1 portabled meter
(NEMA 4X and NEMA 7 wall)
• RS232 Cable for IP40 Portable meter 4CS 0 0
• Submersible sensor cable (NEMA 4X and 0CT1 1
NEMA 7 wall) • I/O adapter for IP66 Weather proof portable 3 AD 0 0
meter
• Standard and plenum sensor cable 1CT0 1
(FUS1020) Universal Sensor Test Blocks

• Standard, plenum and armored sensor cable 2CT0 1 • Test block for size A and B universal sensors 0 TB1 0
(compact NEMA 7) • Test block for size C and D universal sensors 0 TB2 0
• Submersible sensor cable (compact 2CT1 1 Field Manuals
NEMA 7)
• CD with documentation for SITRANS F US D) A5E02830664-01
• Clamp-on RTD cable termination kit for stan- 0CT2 1 Clamp-on ultrasonic flowmeters (English)
dard RTD
D) Subject to export regulations AL: N, ECCN: EAR99H.
• Clamp-on RTD cable termination kit for sub- 0CT3 1
mersible RTD
• Insert RTD cable termination kit 0CT4 1

4/360 Siemens FI01 · 2011


© Siemens AG 2010

Flow Measurement
SITRANS F US Clamp-on
Accessories/Spare parts
Sensor cable selection chart (Dedicated, pair) Accessories - Standard MLFB offering
Sensor cable codes for length and type options Description Order No.
Cable length m Standard Submersible Plenum Armored Insert RTD size 1 D) 7ME3950-1TJ10
(ft) -40…+80 °C -40…+80 °C -40…+200 °C -40…+80 °C
(-40…+176 °F) (-40…+176 °F) (-40…+392 °F) (-40…+176 °F) Thermowell size 1 w/lagging D) CQO:1012TW-1L
Order code EZ Clamp 1 ... 24 inch D) CQO:1012Z-1
6 (20) K01 K11 K21 K31 Junction Box for Clamp RTD D) CQO:992ECJ
15 (50) K02 K12 K22 K32 Term kit standard, Plenum, Armored sensor D) 7ME3960-0CT01
30 (100) K03 K13 K23 K33 cable

46 (150) K04 K14 K24 K34 Term kit Submersible sensor cable D) 7ME3960-0CT11

61 (200) K05 K15 K25 K35 C1 Weld seal D) 7ME3960-0WS20

91 (300) K06 K16 K26 K36 D1 Weld Seal D) 7ME3960-0WS30


C2 Weld Seal D) 7ME3960-0WD20
D2 Weld Seal D) 7ME3960-0WD30
Sensor cable selection chart (FUP1010, Portable FUE1010,
pair) Straps size 2 D) 7ME3960-0SM11

Sensor cable codes for length and type options Straps size 3 D) 7ME3960-0SM21 4
Cable length Standard Plenum Straps size 4 D) 7ME3960-0SM31
m (ft) -40 ... + 80 °C -40 ... + 200 °C
(-40 ... +176 °F) (-40 ... +392 °F) Weld seal sensors C2 FM D) 7ME3950-1SN00

Order Code Weld seal sensors D1 FM D) 7ME3950-1SP00

6 (20) K01 K21 Weld seal sensors D2 FM D) 7ME3950-1SQ00

15 (50) K02 K22 Weld seal sensors D4 FM D) 7ME3950-1SR00

30 (100) K03 K23 Weld seal sensors C2 ATEX D) 7ME3950-2SN00


Weld seal sensors D1 ATEX D) 7ME3950-2SP00
Weld seal sensors D2 ATEX D) 7ME3950-2SQ00
RTD cable selection chart (Dedicated, each)
Weld seal sensors D4 ATEX D) 7ME3950-2SR00
RTD cable codes for length and type
Weld seal sensors Gas C2 FM D) 7ME3950-1HN00
Cable Standard Submersible for insert RTD for submersible
length insert RTD Weld seal sensors Gas D1 FM D) 7ME3950-1HP00
m (ft) -40 … +200 °C -40 … +200 °C -40 ... +200 °C -40 ... +200 °C
(-40 … +392 °F) (-40 … +392 °F) (-40 ... 392 °F) (-40 ... 392 °F) Weld seal sensors Gas D2 FM D) 7ME3950-1HQ00
Order code Weld seal sensors Gas D4 FM D) 7ME3950-1HR00
6 (20) R01 R11 R21 R31 Weld seal sensors Gas C2 ATEX D) 7ME3950-2HN00
15 (50) R02 R12 R22 R32 Weld seal sensors Gas D1 ATEX D) 7ME3950-2HP00
30 (100) R03 R13 R23 R33 Weld seal sensors Gas D2 ATEX D) 7ME3950-2HQ00
46 (150) R04 R14 R24 R34 Weld seal sensors Gas D4 ATEX D) 7ME3950-2HR00
61 (200) R05 R15 R25 R35 Standard MLFB product offering represents 4 to 6 weeks delivery time.
91 (300) R06 R16 R26 R36 D) Subject to export regulations AL: N, ECCN: EAR99H.

RTD cable selection chart (FUP1010, Portable FUE1010, each)