Вы находитесь на странице: 1из 3

MASTERTOP® 1328 AS

Formerly Conifloor AS-PUR


Anti static, self smoothing flooring system

DESCRIPTION PROPERTIES
MASTERTOP 1328 AS is a self-smoothing, antistatic, a. Components
solvent free, polyurethane flooring system. The cured Supply Colour Density
floor exhibits excellent antistatic properties, and finishes form kg/L
to a smooth seamless surface with an attractive
appearance that can be easily maintained in a hygienic Mastertop Primer 9 liquid amber 1.10
condition. Due to the polyurethane base, the system Part A
exhibits an enhanced abrasion and cracking resistance. Mastertop Primer 9 liquid amber 1.05
Part B
RECOMMENDED FOR
Mastertop BC 375 liquid coloured 1.40*
MASTERTOP 1328 AS is recommended for floors in AS Part A
environments where static electricity and stray currents
Mastertop BC 375 liquid amber
produced by friction, pose risks of explosion or
AS Part B
interference with the function or the production of
electronic parts. It is ideal for floors in: Mastertop liquid white 1.07*
• electronic industries CP687WAS Part A
• wafer and PC component production Mastertop liquid black
• synthetic fibre mills CP687WAS Part B
• processing and handling of combustible goods
Mastertop liquid white 1.07*
• operating theatres and recovery rooms
CP689WAS Part A
FEATURES AND BENEFITS Mastertop liquid coloured
CP689WAS Part B
Antistatic Dissipates static charges that
* Part A and Part B mixed
could cause sparks or damage
electronic parts. b. Mixed systems
Good chemical Durable in chemically
Compon Mix ratio
resistance aggressive areas.
ents by weight
Easy to maintain Allows floor surface to be
maintained in a hygienic state. Mastertop Primer 9 A:B 100:27
Seamless Is free of joints that collect dirt Mastertop CP687WAS A:B 4:6
and allow ingress of pollutants.
Mastertop CP689WAS A:B 3:2
Complies with all Complies with DIN 51953, DIN
international EN 1081,IEC and NFPA. BS Mastertop BC 375 AS A:B 4:1
Standards 2080, UL 779

TYPICAL PERFORMANCE DATA Pot-life (minutes)


(7 days cure @ 20ºC using A4, B4, X1 and F1A) @ 10°C @ 20°C @ 30°C
Compressive (DIN 1164) 65 N/mm 2

Mastertop Primer 9 70 35 20
Flexural strength (DIN 1048) 35 N/mm 2

Bond strength (DIN ISO 4624) > 1.5 N/mm 2


Mastertop 120 60 30
Abrasion resistance 98 mg CP687WAS
(DIN ISO 53154)
Mastertop 120 60 30
Modulus of elasticity (DIN 1048) 9000 N/mm 2

CP689WAS
Coeff. of linear expansion : 8 x 10-5 K-1
(DIN 53752) Mastertop BC 375 60 30 20
Service Temperature : -20°C to 60°C AS
Application Temperature : Minimum 10°C
Maximum 35°C

Head Office Factories Representative Offices


Plaza GRI 10th & 11th Floor Jl. Daan Mogot Km.14 Jl. Jababeka V Blok I-1 Grand Residence Office Park, Komp. Pertokoan Royal Sunggal
Jl. HR Rasuna Said Blok X-2 No.1 Cengkareng, Cikarang Industrial Estate 1st Floor Jl. Gagak Hitam No. A-12
Jakarta 12950 Jakarta 11750 Bekasi 17530 Jl. Darmo Harapan Complex 1 Ring Road – Sunggal
Tel.: (6221) 5262481, 5262505 Tel.: (6221) 6190007 Tel.: (6221) 8934339 Surabaya 60187 Medan, Sumatera Utara 20128
Fax: (6221) 5262493, 5262515 Fax: (6221) 6190741 Fax: (6221) 8934342 Tel.: (6231) 7326705 Tel.: (6261) 8447110
Fax: (6231) 7326730 Fax: (6261) 8444072
MASTERTOP® 1328 AS
Curing time (days) second primer sealer/coat may be required. If in doubt
apply a sample patch of body coat.
@ 10°C @ 20°C @ 30°C
CONDUCTIVE PRIMER
Mastertop Primer 9 5 2 1
Mixing
Mastertop 7 5 2 Use a low speed (300 rpm) electric drill fitted with a
CP687WAS paint mixer or a wing type paddle.
Premix one set of Mastertop CP687WAS or Mastertop
Mastertop 7 5 2 CP689WAS for at least 3 minutes until the mix is uniform
CP689WAS
and free of streaks.
Mastertop BC 375 10 5 2 Placing
AS Please refer to relevant Product Data Sheet.
Maximum permissible relative humidity Note:
If a resistivity of >1x104 to<1x106 is required, DIN 51953
@ 10°C at >23°C use Conductive primer Mastertop CP687WAS If a
All components 75 % 90 % resistivity of >1x106 to<1x109 is required, DIN 1081 use
Conductive primer Mastertop CP689WAS.
For other standards, please consult the nearest BASF
APPLICATION Construction Chemicals representative.
Copper grounding strips
Surface Preparation When the primer has cured, self-adhesive copper strips
The compressive strength of the substrate shall not be 10 to 20 mm wide and 300 to 400 mm long are bonded
less than 30 N/mm2. The substrates in contact with the to the primed surface. As a rule, one strip per 100 m2 of
ground must have a vapour barrier installed in floor area complies with all norms. For large areas, it is
compliance with DIN 18195 or equivalent, or be primed prudent to place one or two strips longitudinal and
with Mastertop Primer 9. The moisture content of the parallel to the walls. The above mentioned strips are
substrate shall not be higher than 8% throughout (check grounded near a column in the mid section of the floor.
using with CM equipment). The temperature of the However, consult with the owner or the consultant
substrate must be at least 3°C above the current dew regarding possible special grounding requirements. The
point temperature. placed copper strips are subsequently connected to an
Correct substrate preparation is critical for optimum approved ring conductor / bus bar which is connected to
performance. Surfaces must be structurally sound, an approved ground pole. It is beyond the scope of the
clean, and free from loose particles, oil, grease, and all flooring material supplier to design, specify or install the
other contaminants. grounding system, such work must be carried out and
Remove oil, grease and wax contaminants by scrubbing designed by a qualified electrician or in conjunction with
with industrial grade detergent or degreasing the owner’s safety or quality control officer.
compounds followed by mechanical cleaning. Cement
laitance, loose particles, mould release agents, curing BODY COAT
membrane and other contaminants must be removed Mixing
from the surface by shot blasting, Blastrac®, scarifying or Use a low speed (300 rpm) electric drill fitted with a paint
gritblasting followed by vacuum cleaning. After mixer or a wing type paddle.
pretreatment of the substrate, the bond strength of the Mix one unit of Mastertop BC 375 AS Part A with one
substrate must be at least 1.5 N/mm2 (check with an unit Mastertop BC 375 AS Part B and mix for at least 3
approved pull-off tester at load rate 100 N/s). minutes or until the mix is uniform in colour and free of
streaks.
Fill surface irregularities such as blowholes, cracks, Placing
honeycombs, etc. with a repair mortar to achieve a Depending on the substrate condition, apply 2.2 to 2.5
smooth and level surface. kg/m2 of the mix; pour out the whole mix at once into
Protect walls and columns against resin splashes using pours being approximately 200 to 300mm wide running
masking tape and polythene sheeting. parallel to the work direction. Distribute and level the
material with a notched trowel of the following teeth size,
PRIMER width / height / separation: 3/5/10mm.
Mixing Allow the placed material to rest for 10 to 15 minutes,
Use a low speed (300 rpm) electric drill fitted with a then de-aerate with a spike roller.
paint mixer or a wing type paddle. Following application of the MASTERTOP 1328 AS,
Premix one unit of Mastertop primer 9 Part A with one protect coated area for at least 24 hours after laying from
unit of Mastertop Primer 9 Part B for at least 3 minutes spillage, dust, insects, small animals, traffic, rain,
until the mix is uniform and free of streaks. moisture, etc.
Placing
Immediately after mixing, pour the material onto the
substrate and spread the mixed material using a
squeegee or paint roller. The main purpose of this primer
coat is to seal the substrate completely and avoiding
airbubbles in the body coat. On very porous substrates a
MASTERTOP® 1328 AS
ESTIMATING DATA PRECAUTIONS
For thickness of 2.0mm MASTERTOP 1328 AS contains certain chemicals
System Product kg/m2 Thickness which can cause skin irritation if exposed and respiratory
mm reaction if inhaled. Wear gloves, masks and use hand
barrier cream while handling the product. Wash
Primer Mastertop 0.1 – 0.3 0.3 - 0.4 thoroughly after handling.
Primer 9 Should skin contact occur, wash immediately with soap
Conductive Mastertop 0.08 - 0.15 0.1 -0.15 and water or an effective hand cleaner.
Primer CP687WAS or In case of accidental eye contact, wash with copious
CP689WAS quantity of water and immediately seek medical advice.
If ingested, do not induce vomiting. Consult a doctor
Body coat Mastertop 2.2 – 2.5 1.5-2.0
immediately.
BC375 AS
Vapours of solvents used for cleaning can be irritating. It
is therefore recommended that cleaning be done in
PACKAGING wellventilated areas.
For detailed Health, Safety and Environmental
Mastertop Body 375 AS : 30.0 kg/set Recommendations, please consult and follows all
Mastertop Primer 9 : 30.0 kg/set instructions on the product Material Safety Data Sheet.
Mastertop CP687WAS : 15.0 kg/set Fire: Keep away from sources of ignition. Do not smoke
Mastertop CP689WAS : 25.0 kg/set whilst handling the product.
Flash point: 110°C.
SHELF LIFE MT 1328AS/06/0301
MASTERTOP 1328 AS can be kept for 12 months from
date of manufacture if stored in original unopened
packaging, in a dry enclosed place at temperatures
between 15 to 35ºC without exposure to direct sunlight.

The technical information and application advice given in this BASF Construction Chemicals
publication are based on the present state of our best scientific and practical knowledge. As the
STATEMENT OF information herein is of a general nature, no assumption can be made as to a product's suitability for a
RESPONSIBILITY particular use or application and no warranty as to its accuracy, reliability or completeness either
expressed or implied is given other than those required by law. The user is responsible for checking the
suitability of products for their intended use.
Field service where provided does not constitute supervisory responsibility. Suggestions made by
BASF Construction Chemicals either orally or in writing may be followed, modified or rejected by the
NOTE owner, engineer or contractor since they, and not BASF Construction Chemicals, are responsible for
carrying out procedures appropriate to a specific application.

Вам также может понравиться