Академический Документы
Профессиональный Документы
Культура Документы
Sensors
Photonic Sensors
Swiss Laser Net Workshop Biel
17.09.09
Thomas Hessler
Overview
Applications
LEISTER Process Technologies
LEISTER Corporate
Photonic Sensor Activities at Axetris
Laser Scan
λ
IR Source
Detector
Gas Laser
Gas
Volume Reference Volume
p. 6
Technology - TDLS Measurement Principle
High linearity Intrinsic reference channel
Laser signal information: Optical system & reference information:
Laser intensity & wavelength On modulation frequency f
vary linearly with drive current Gas concentration signal:
Gas absorption signal: On modulation frequency 2f
The detector sees less intensity
as the laser hits the gas line
I No gas f
A
Laser signal λK
information
λL
Gas t
absorption
information With gas
I
Laser Scan λ 2f t
Technology – 1st or 2nd Order
CO2 Fundamental
Absorption Band
Absorption
1st Envelope
Overtone
2nd
Overtone
Absorption (a.U.)
Results in high selectivity
Example CO2/CO:
Envelopes overlap, single
absorption lines do not
TDLS can measure gases with resolved rotation & vibration bands, i.e.
gases with small molecules.
E.g. alkanes: Ok for CH4, C2H6, but not for longer chains
Technology - Laser Gas Monitor
Electronics Mirror
Laser Diode
Business Focus
Applications in
Process control & environmental monitoring
Industrial safety
Climate & air conditioning
Medical technology
TDLS Gas Monitor Set-up
Measurement
interface to customer:
IR Microsystems provides:
Self-contained measurement
system with integrated optics
(probe or flow-cell) Flow: LGD F200 (H) Ambient / heated
Digital or analog data output
Customer provides:
Input Power (10-30 V)
Conditioned/filtered gas
Purge gas (where necessary)
Flow-through cell
Optional heating up to 190°C
Modular design
LGD F 200 (H) - Specifications
System Specifications
LGD F200H layout flow-through
Meas. temp. flow-through ambient, optional up to 190°C
Measurement cell layout modular, different path lengths depending on gas & applic.
Measurement range ppm- or %-ranges depending on gas & applic.
Drift below detection limit
Characteristics
High Selectivity 3 ~ ~ 2
High Stability 3 ~ ~ 2
Calibration-free 3 2 2 2
Cont. Sensor status monitoring 3 3 3 2
Non-contact measurement 3 3 2 2
Acquisition cost ~ ~ 3 3
Low cost-over-time 3 ~ ~ ~
Rugged 3 3 2 3
Overload damage or ageing 3 3 ~ 2
Compact multigas ~ 3 2 3
Fast Recovery time 3 3 3 2
Selected Applications
NH3
SCR / Emission Control
Safety / Refrigeration
Livestock Climate Control
CH4
Environmental Monitoring /
Landfill
Emission Control
Main application specific USP Selectivity
Non-contact
Precision at T = const.: 0.3 ppm
Peak-Peak Noise -40°C – 65°C: 2 ppm
12
11
Set 10 ppm
10
Set 9ppm
9
Set 8 ppm
8
Set 7 ppm
7
Set 6 ppm
6 Set 5 ppm
5
4
3
Set 2 ppm
2
1
Set 0 ppm
0
500 1000 1500 2000 2500
Time [s]
resolution
LGD F200 NH3 - measurements
linearity reproducibility
LGD F200 NH3 - measurements
Safety / Refrigeration
Main application specific USP Selectivity Reliability
Cost-over-time
Precision at T = const.: 0.3 ppm
Peak-to-Peak Noise -40°C – 65°C: 2 ppm
14
CH [ppm]
6.9 ppm
8
6 ppm
LGD F200 offers real time,
4
5 ppm
6
monitoring with high dynamic range
3.9 ppm
4
Selective measurement of methane
2 2 ppm
0 ppm
0
0 500 1000 1500
Time [s]
Summary