8.5.3 Radio Layer Configuration


z The two cells that form a DC cell group must meet the following requirements:Both cells belong
to the same carrier, and are located in the same frequency and the same sector. Both cells
belong to the same downlink resource group.

z Both cells share the same TCELL, with neighboring frequency points (the difference between the
frequency points is not more than 5 MHz).

z Two carriers in a sector are recommended to share a transmitting channel, namely, to share a
RRU.

z When two RRUs support the DC-HSDPA feature, the cascade mode is recommended between
two RRUs.

RNC
z Modify the version of the NodeB/CN to R9/R8 (the DC-HSDPA feature is supported in R8 and
later versions, and the corresponding protocol version of RAN13 is R9. The R9 protocol
version is recommended for the NodeB, and the R8 protocol version is recommended for the
CN.

MOD UNODEB: NodeBId=xxx, NodeBProtclVer=R9;

MOD UCNNODE: CnOpIndex=0, CNId=0, CNDomainId=PS_DOMAIN, CNProtclVer=R8;

z Turn on the algorithm switch of the DC HSDPA feature.

SET UCORRMALGOSWITCH: CfgSwitch=CFG_HSDPA_DC_SWITCH-1;

z Turn on the algorithm switch of the 64QAM feature to support the DC-HSDP feature (42 Mbit/s).

SET UCORRMALGOSWITCH: CfgSwitch=CFG_HSDPA_64QAM_SWITCH-1;

z Use the DC HSDPA technology as a priority.

SET UFRC: MIMO64QAMorDCHSDPASwitch=DC_HSDPA;

z A DC-HSDPA user travels from a non test zone to a three-carrier test zone. The three-carrier f1
test zone does not support the DC-HSDPA feature, and requires you to periodically make a
DRD to the f2 or f3 test zone to serve as the DC. Therefore, you must enable the function.

SET UFRC: RetryCapability=64QAM-1&DL_L2_ENHANCE-1&DC_HSDPA-1;

z Enable HSDPA on a flow service.

SET UCORRMALGOSWITCH: MapSwitch=MAP_PS_STREAM_ON_HSDPA_SWITCH-1;

z Set an HSDPA threshold.

SET UFRCCHLTYPEPARA: DlStrThsOnHsdpa=D64, DlBeTraffThsOnHsdpa=D64;

mk:@MSITStore:C:\Users\f80015450\Desktop\Claro%20Second%20Switchroom\DC-HSP... 11/07/13
Release Notes Page 2 of 5

z Activate the HSDPA function of a cell.

ADD UCELLHSDPA: CellId=1, AllocCodeMode=Automatic, CodeAdjForHsdpaSwitch=ON;

ACT UCELLHSDPA: CellId=1;

z Turn on the functional switches for the 64QAM feature, the downlink L2 enhanced feature, and
the DC-HSDPA feature.

MOD UCELLALGOSWITCH: CellId=1, HspaPlusSwitch=64QAM-1&DL_L2ENHANCED-


1&DC_HSDPA-1;

z Activate the license for the downlink peak rate of 42 Mbit/s.

SET LICENSE: SETOBJECT=UMTS, ISPRIMARYPLMN=YES,


FUNCTIONSWITCH5=EHSPA_42M_DL-1;

z Set the TCELL in a DC cell group, and requires that the values of the TCELL must be the same
(cell deactivation is required to modify the value of TCELL).

MOD UCELLSETUP: CellId=0, TCell=CHIP0;

MOD UCELLSETUP: CellId=1, TCell=CHIP0;

z The following parameters need to be queried first. For the recommended baseline parameters, you do not
need to modify them.

z The following parameters are optional and related to networking policies. A negotiation with the network
planning department is required.

z Baseline parameters are recommended for QoS guarantee configuration of the DC. Detailed
values are based on the requirements of carriers.

To enable the mapping between the ARP and SPI, run the following commands to configure
the user level of each ARP.

ADD UOPERUSERPRIORITY: ARP1Priority=Gold, ARP2Priority=Gold,


ARP3Priority=Gold, ARP4Priority=Gold, ARP5Priority=Gold, ARP6Priority=Silver,
ARP7Priority=Silver, ARP8Priority=Silver, ARP9Priority=Silver, ARP10Priority=Silver,
ARP11Priority=Copper, ARP12Priority=Copper, ARP13Priority=Copper,
ARP14Priority=Copper, CnOpIndex=0;

Set the mapping from user service types and levels to the SPI as follows:

ADD UOPERSCHEDULEPRIOMAP: CnOpIndex=0, TrafficClass=INTERACTIVE,


UserPriority=SILVER, THPClass=High, SPI=5;

Run the ADD UOPERUSERGBR command to configure the GBR of BE services. Example:

ADD UOPERUSERGBR: CnOpIndex=0, TrafficClass=INTERACTIVE, THPClass=High,


BearType=HSPA, UserPriority=SILVER, UlGBR=D64, DlGBR=D64;

mk:@MSITStore:C:\Users\f80015450\Desktop\Claro%20Second%20Switchroom\DC-HSP... 11/07/13
Release Notes Page 3 of 5

z DC measurement control configuration

Configure two measuring switches (GBP and PBR) in a cell.

MOD UCELLALGOSWITCH: CellId=1, NBMCacAlgoSwitch=HSDPA_GBP_MEAS-


1&HSDPA_PBR_MEAS-1;

Configure a basic measurement period as 200ms.

SET ULDM: ChoiceRprtUnitForDlBasicMeas=TEN_MSEC, TenMsecForDlBasicMeas=20;

Configure the measuring period of the HSPA GBP and HSPA PBR as 1s.

SET ULDM: ChoiceRprtUnitForHsdpaPwrMeas=TEN_MSEC,


TenMsecForHsdpaPwrMeas=100;

SET ULDM: ChoiceRprtUnitForHsdpaRateMeas=TEN_MSEC,


TenMsecForHsdpaPrvidRateMeas=100;

z DC admission control configuration

Run the following command to enable the HSPA+ or HSPA admission control switch:

MOD UCELLALGOSWITCH: CellId=1, NBMCacAlgoSwitch=HSDPA_UU_ADCTRL-1;

Enable the CE resource admission control of a cell.

SET UCACALGOSWITCH: CacSwitch=NODEB_CREDIT_CAC_SWITCH-1;

MOD UCELLALGOSWITCH: CellId=1, NBMCacAlgoSwitch=CRD_ADCTRL-1;

z DC DRD configuration

Turn on the DRD control switch and the blind handover switch of an intra-frequency co-
coverage cell of HSPA+.

SET UCORRMALGOSWITCH: DrSwitch=DR_RRC_DRD_SWITCH-


1&DR_RAB_SING_DRD_SWITCH-1;

ADD UINTERFREQNCELL: RNCId=1, CellId=1, NCellRncId=1, NCellId=2, CIOOffset=0,


SIB11Ind=TRUE, SIB12Ind=FALSE, TpenaltyHcsReselect=D0, BlindHoFlag=TRUE,
NPrioFlag=FALSE, InterNCellQualReqFlag=FALSE;

z DC load control configuration

Turn on the HSPA status transition switch. Configure as follows:

SET UCORRMALGOSWITCH: DraSwitch = DRA_PS_BE_STATE_TRANS_SWITCH-1&


DRA_PS_NON_BE_STATE_TRANS_SWITCH-1& DRA_HSDPA_STATE_TRANS_SWITCH-
1& DRA_HSUPA_STATE_TRANS_SWITCH-1;

Turn on the algorithm switch for load reconstruction, code resource reconstruction, and CE
resource reconstruction. Configure as follows:

MOD UCELLALGOSWITCH: CellId=1, NBMLdcAlgoSwitch=UL_UU_LDR-

mk:@MSITStore:C:\Users\f80015450\Desktop\Claro%20Second%20Switchroom\DC-HSP... 11/07/13
Release Notes Page 4 of 5

1&DL_UU_LDR-1&CELL_CODE_LDR-1&CELL_CREDIT_LDR-1;

Turn on the downlink load balance switch of the DC-HSDPA feature as follows:

SET UDRD: LdbDRDSwitchHSDPA=ON; (valid for all HSDPA users)

MOD UCELLDRD: CellId=1, LdbDRDSwitchHSDPA=ON;

Turn on the DC-HSDPA uplink load balance switch as follows:

SET UDRD: ULLdbDRDSwitchDcHSDPA=ON; (only valid for DC-HSDPA users)

MOD UCELLDRD: Cell ID = 1, ULLdbDRDSwitchDcHSDPA=ON; (only valid for DC-


HSDPA users)

z DC moulding configuration (shared by 64QAM, MIMO and DC)

SET UCMCF: EHSPACMPermissionInd=TRUE;

NodeB
z Configure DC-HSDPA

Add a local Cell 1 and a local Cell 2.

ADD LOCELL: LOCELL=1;

ADD LOCELL: LOCELL=2;

z Configure a cell group for the DC-HSDPA feature, namely, configure a local Cell 1 and a local
Cell 2 as such a cell group (cell deactivation is required for adding a cell group for the DC-
HSDPA feature).

ADD DUALCELLGRP: FIRSTLOCELL=1, SECONDLOCELL=2;

Turn on the switch for traffic-based auxiliary carrier activation and deactivation in the DC-
HSDPA feature (not required if this function is not enabled).

SET MACHSPARA: LOCELL=1, SECCELLACTDEASW=ON;

SET MACHSPARA: LOCELL=2, SECCELLACTDEASW=ON;

The following parameters need to be queried first. For the recommended baseline parameters, you do not need
to modify them.

z Dynamic code configuration for DC-HSDPA cells

You are advised to enable the dynamic code of the NodeB.

SET MACHSPARA: LOCELL=1, DYNCODESW=OPEN;

SET MACHSPARA: LOCELL=2, DYNCODESW=OPEN;

z DC-HSDPA scheduling algorithm configuration

A default scheduling algorithm (EPF scheduling algorithm) is recommended.

mk:@MSITStore:C:\Users\f80015450\Desktop\Claro%20Second%20Switchroom\DC-HSP... 11/07/13
Release Notes Page 5 of 5

SET MACHSPARA: LOCELL=1, SM=EPF;

SET MACHSPARA: LOCELL=2, SM=EPF;

z DC-HSDPA flow control algorithm configuration

Default parameters are recommended for flow control. The flow control policy is automatically
selected between DYNAMIC_BW_SHAPING and NO_BW_SHAPING parameters using
the congestion detection mechanism of the NodeB.

SET HSDPAFLOWCTRLPARA: SN=7, SBT=BASE_BOARD, BEAR=IPV4, PT=ETH,


SWITCH=BW_SHAPING_ONOFF_TOGGLE; (example: IP transmission on the control board
of the DBS3900/BTS3900 7 slot)

z DC-HSDPA power control configuration

Default parameters are recommended for HS-SCCH power control configuration. Adjust HS-
SCCH power control configuration according to CQI, with the frame error rate of 1%.

SET MACHSPARA: HSSCCHPWRCMINDCH=CQI, HSSCCHFERTRGTINDCH=10;

A default parameter (5%) is recommended to configure the power headroom of a cell.

SET MACHSPARA: PWRMGN=5;