Вы находитесь на странице: 1из 6

KX-MB2025EXW/KX-MB2030EXW

12.3.6.1. CALL SERVICE 1


"CALL SERVICE 1" means that the polygon motor inside the LSU does not rotate.
The rotation of the polygon motor is detected by IC300-F23pin (NREADY).

120
KX-MB2025EXW/KX-MB2030EXW

12.3.6.2. CALL SERVICE 2


"CALL SERVICE 2" means that the synchronous signal out of the LSU cannot be detected.
The synchronous signal out of the LSU is detected by IC 300-G23pin. (NHSYNC)

Note:
As for the "Pulse" waveform of the above flow chart, see the timing chart.

121
KX-MB2025EXW/KX-MB2030EXW

12.3.6.3. CALL SERVICE 3


"CALL SERVICE 3" means that the temperature of the fuser does not rise up to or exceed a constant temperature.
The temperature is monitored with the thermistor inside the fuser and detected with the voltage input into IC 300-D19.

* When Call Service 3 is occurred, the cause can be distinguished by service mode 655.
Refer to CALL SERVICE Troubleshooting Guide (P.119) for details.

122
KX-MB2025EXW/KX-MB2030EXW

12.3.6.4. CALL SERVICE 4


"CALL SERVICE 4" means that the FAN does not run or the running of the FAN cannot be detected normally.
The running of the FAN is detected by IC300-AC20 and W24pin. "CALL SERVICE 4" is displayed when it detects NG three times
continuously.
After repairing, copy three times.If “CALL SERVICE 4 “ is displayed, check again.

123
KX-MB2025EXW/KX-MB2030EXW

12.3.6.5. CALL SERVICE 5


“CALL SERVICE 5” means that Engine DC motor’s rotation detection signal (LD) does not become Low.

124
KX-MB2025EXW/KX-MB2030EXW

12.3.6.6. CALL SERVICE 6


“CALL SERVICE 6” indicates that abnormal charge voltage is output from the high voltage unit.