OPERATING DATA INDE R25.

12 MULTI
OPERATORS REDA - (IN/IND)
3BW74586AAAAPQAHA Ed.08.En

2004-02-11

TECHNICAL DIVISION

ALCATEL E10B

SOFTWARE DOCUMENTATION

TAP - COMMONS

___________

SUNDRY DOCUMENTS
+---+-----+-------------------+-------------------------+-------------------------+
! 08! 0312! IND/DON ! ! VND/R&D !
+---+-----+-------------------+-------------------------+-------------------------+
! 07! 0301! IND/DON ! ! VND/R&D !
+---+-----+-------------------+-------------------------+-------------------------+
! 01! 0109! P.ENGEL ! ! JL FLOCH !
+---+-----+-------------------+-------------------------+-------------------------+
! ED! DATE! CHANGE NOTE ! APPRAISAL AUTHORITY ! ORIGINATOR !
+---+-----+-------------------+-------------------------+-------------------------+
+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 1/145 !
+---------------------------------------------------------------------------------+
TABLE OF CONTENTS

HISTORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

REFERENCE DOCUMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

PREFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

1 SUBSCRIBER MANAGEMENT . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.1 GENERAL PARAMETERS . . . . . . . . . . . . . . . . . . . . . . . . 5
1.2 MARK PARAMETERS . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.3 TYPE PARAMETERS . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.4 CATEGORY PARAMETERS . . . . . . . . . . . . . . . . . . . . . . . . 20
1.5 COMPANY PARAMETERS (CENTREX) . . . . . . . . . . . . . . . . . . . 33

2 ADDRESS INFORMATION MANAGEMENT . . . . . . . . . . . . . . . . . . . . 37


2.1 PRE-ANALYSIS . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
2.2 ANALYSIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
2.3 ROUTING MANAGEMENT . . . . . . . . . . . . . . . . . . . . . . . . 46
2.3.1 General parameters . . . . . . . . . . . . . . . . . . . . . . 46
2.3.2 Filtering parameters . . . . . . . . . . . . . . . . . . . . . 51
2.3.3 TYFA-TYPU description . . . . . . . . . . . . . . . . . . . . . 52
2.3.4 Routing type parameters . . . . . . . . . . . . . . . . . . . . 61
2.4 NETWORK PARAMETERS . . . . . . . . . . . . . . . . . . . . . . . . 75

3 CIRCUIT GROUP MANAGEMENT . . . . . . . . . . . . . . . . . . . . . . . 76


3.1 GENERAL PARAMETERS . . . . . . . . . . . . . . . . . . . . . . . . 76
3.2 NO 7 PARAMETERS . . . . . . . . . . . . . . . . . . . . . . . . . . 79
3.3 SIGNALISATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 82
3.4 CIRCUIT GROUP CATEGORIES . . . . . . . . . . . . . . . . . . . . . 86
3.4.1 Variant of signalisation (VSG) . . . . . . . . . . . . . . . . 86
3.4.2 Standard categories . . . . . . . . . . . . . . . . . . . . . . 92
3.4.3 Standard discriminations . . . . . . . . . . . . . . . . . . . 98

4 CALL FORWARDING . . . . . . . . . . . . . . . . . . . . . . . . . . . 114


4.1 CALL FORWARDING MANAGEMENT . . . . . . . . . . . . . . . . . . . 114
4.2 DESCRIPTION OF CALL FORWARDING . . . . . . . . . . . . . . . . . 119

5 CHARGING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128

6 TONES AND FREQUENCIES . . . . . . . . . . . . . . . . . . . . . . . . 133


6.1 TONES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
6.2 SIGNALLING FREQUENCIES . . . . . . . . . . . . . . . . . . . . . 137
6.3 INAP NO- SYSTEM FILM NO CORRESPONDENCES . . . . . . . . . . . . . 141

7 V5.2 ACCESS MANAGEMENT . . . . . . . . . . . . . . . . . . . . . . . 143

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 2/145 !
+---------------------------------------------------------------------------------+
HISTORY

01.EN of 01-09-17
Creation

02.EN of 02-04-19
RT 01LEX100922, CE.520

03.EN of 02-07-16
FA 3BW74585AAAAPJDCB.04

04.EN of 02-08-16
prendre en compte le fichier des tonalit§es

05.EN of 02-09-13
Mise | jour des valeurs pour overlap

106.EN of 02-10-14
Introduction de l'op§rateur VSNL

07.EN of 03-01-21
AFR OCBA01FAG084602 TYFA TYPU Centrex
D§finition des VERS sur interface V52
Suppression ISUP V2 International
Description des discriminations DFD1 et DFH1
Modification de la d§finition NBA
Ajout des pr§analyses manquantes

08.EN of 03-06-17
AFR OCBA01FAG100476
Prise en compte de la discri DQ3 fct 3
Prise en compte de §volution des trames standard
AFR OCBA01CAG110284
Ajout discri de faisceau fct.48 Call broken if no caller identity
AFR OCBA01CAG111390
Cr§ation profils V52 sp§cifique AN

REFERENCE DOCUMENTS

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 3/145 !
+---------------------------------------------------------------------------------+
PREFACE

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 4/145 !
+---------------------------------------------------------------------------------+
1 SUBSCRIBER MANAGEMENT (x)

1.1 GENERAL PARAMETERS (x)

+-------------------------------------------------------------------------+
| (S) TITLE : Management of single and grouped lines |
| Digital or analogue subscribers |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| ND = | Digit | Designation number 5 to 11 digits. The thousands |
| | | group number can take the values 0 to 9 and |
| | | A (*, 11), J (|, 12), S (13), C (14) |
|---------+--------+------------------------------------------------------|
| NR = | UR-eqt | Standard equipment number: UR: 1 to 255 |
| | | Eqt 1 to 5119 |
|---------+--------+------------------------------------------------------|
| NE = |URA | Equipment number at the distribution frame: |
| | -REG | /URA: 1 - 255 / REG 0 - 63 on UR type |
| | -BRO | /BRO 0 - 127 |
|---------+--------+------------------------------------------------------|
| AFCT = | UR - | Equipment number on IRM: UR: 1 to 255 |
| | MIC - | UR: 1 to 255 PCM: 0 to 3 (SMT1G) or 15 (SMT2G) |
| | TS | TS: 1 to 31 |
|---------+--------+------------------------------------------------------|
| ACH = | 1-4095 | Routing number |
|---------+--------+------------------------------------------------------|
| NDG = | digits | Main group designation number |
|---------+--------+------------------------------------------------------|
| NDP = | digits | Preferential group designation number |
|---------+--------+------------------------------------------------------|
| NSG = | 1 or 2 | Research sub-group number |
|---------+--------+------------------------------------------------------|
| LOI1 = | 0 or 1 | Research law in sub-group 1 |
|---------+--------+------------------------------------------------------|
| LOI2 = | 0 or 1 | Research law in sub-group 2 |
|-------------------------------------------------------------------------|
| LOIx=0: (default value) cyclical research through the sub-groups |
| with random selection of the first eqt in the sub-group. |
| The eqt research is then cyclical within the sub-group. |
| LOIx=1: Systematic research from sub-group 1 then cyclical research |
| through the following ones. Selection of the first eqt. in |
| the sub-group is random then cyclical thereafter. |
|-------------------------------------------------------------------------|
| NAP = |1 - 8175| Access number of digital V5.1/V5.2 AB port |
| |1- 32767| Access number of analogue V5.2 AB port |
|---------+--------+------------------------------------------------------|
| ITV = | TSi-j | TS number - 1<j<2 - 1<i<31 - i<>16 for V5.1 subscrib.|
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 5/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| (S) TITLE : Management of single and grouped lines |
| Digital or analogue subscribers |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| AFUR = | 1 - 223| Functional address of the connection unit. |
| | | Used for V5.2 equipment. |
|---------+--------+------------------------------------------------------|
| INDR = | digit | Digit to be inserted. The number of digits is |
| | | between 1 and 8. Does not apply to groups. |
| | | INDR implies INSPi different from INSP0. |
|---------+--------+------------------------------------------------------|
| SOC = |1 - 1023| Company number if private subscriber (centrex) |
+-------------------------------------------------------------------------+

+-------------------------------------------------------------------------+
| (S) TITLE : Management of single and grouped lines |
| Digital subscribers |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CP = | 0 - 127| Identification number of the Communication Path. |
| | | (V5.2 ISDN subscriber management) |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 6/145 !
+---------------------------------------------------------------------------------+
1.2 MARK PARAMETERS (x)

+-------------------------------------------------------------------------+
| |
| (S) TITLE : Management of single and grouped lines |
| Digital or analogue subscribers |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| MAR = | ART | Call forwarding |
| |--------+------------------------------------------------------|
| | ODDA | Incoming call observation (OABLA) |
| |--------+------------------------------------------------------|
| | ODDD | Outgoing call observation (OABLA) |
| |--------+------------------------------------------------------|
| | ODGA | Incoming call observation: group (OABLA) |
| |--------+------------------------------------------------------|
| | ODGD | Outgoing call observation: group (OABLA) |
| |--------+------------------------------------------------------|
| | OLGX | Standard observation: heavy user groups and lines |
| | | (OLXLA) |
| |--------+------------------------------------------------------|
| | OLDX | Heavy user line observation (line by line) (OLXLA) |
| |--------+------------------------------------------------------|
| | STX | Charging supervision |
| |--------+------------------------------------------------------|
| | NNU | Number not used |
| |--------+------------------------------------------------------|
| | EHS | Access out of service |
| |--------+------------------------------------------------------|
| | ARN | Call forwarding if no answer |
| |--------+------------------------------------------------------|
| | ARO | Call forwarding if busy state |
| |--------+------------------------------------------------------|
| | SECR | Permanent state of Calling Line Identification |
| | | Restriction, activated by user command. |
| |--------+------------------------------------------------------|
| | ASD | Supplementary number present |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 7/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE : Management of single and grouped lines |
| Digital or analogue subscribers |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| | ADM | Delayed notification service activated |
| |--------+------------------------------------------------------|
| | ARC | Controlled access barring |
| |--------+------------------------------------------------------|
| | ARFN | Fixed call forwarding on no answer activated |
| |--------+------------------------------------------------------|
| | ARFO | Fixed call forwarding on busy activated |
| |--------+------------------------------------------------------|
| | ARFT | Unconditional fixed call forwarding activated |
| |--------+------------------------------------------------------|
| | TRS | Transgroup subscriber line (prohibited to centrex |
| | | subscribers, specific to France Télécom) |
| |--------+------------------------------------------------------|
| | USA | Centrex private subscriber (user) |
| |--------+------------------------------------------------------|
| | MRIn | Non-specific marks dedicated to IN services (1 - 32) |
| |--------+------------------------------------------------------|
| | MARJ | Anonymous Call Rejection (ACR activated) |
| |--------+------------------------------------------------------|
| | AMV | Activation of DMV (centrex, Do not disturb facility) |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 8/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE : Management of single and grouped lines |
| Analogue subscriber |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| MAR = | ARV | Mark for alarm call service |
| |--------+------------------------------------------------------|
| | ABS | Subscriber with absent subscriber service, cx. to a |
| | | film or tone (Use of forwarding no. 42) |
| |--------+------------------------------------------------------|
| | ABSO | Subscriber with absent subscriber service, cx. to an |
| | | operator (Use of forwarding no. 108) |
| |--------+------------------------------------------------------|
| | ADN | DO NOT DISTURB activated |
| |--------+------------------------------------------------------|
| | AFI | Activation of the FIE service (centrex) |
| |--------+------------------------------------------------------|
| | ALTF | Active service group ( LATF discr) |
| |--------+------------------------------------------------------|
| | ARL | Local automatic callback activated (centrex) |
| |--------+------------------------------------------------------|
| | FIP | Filter/filtered link privileged (centrex) |
| |--------+------------------------------------------------------|
| | ATT | Call waiting indication |
| |--------+------------------------------------------------------|
| | RLN | Incoming call filtering activated |
+-------------------------------------------------------------------------+

+-------------------------------------------------------------------------+
| |
| (S) TITLE : Management of single and grouped lines |
| Digital subscriber |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| MAR = | LSP | Access bearing semi-permanent links (LL) |
| |--------+------------------------------------------------------|
| | LLP | Access bearing permanent logical links |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 9/145 !
+---------------------------------------------------------------------------------+
1.3 TYPE PARAMETERS (x)

+-------------------------------------------------------------------------+
| |
| (S) TITLE : Management of single and grouped lines |
| Digital or analogue subscribers |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| TY = | LSS | Essential line (priority subscriber) |
| |--------+------------------------------------------------------|
| | MOD | Entitlement to change data in functional units file |
| |--------+------------------------------------------------------|
| | IELP | Line and telephone test disabled |
| |--------+------------------------------------------------------|
| | V51 | User connected in V5.1 - |
| | | Involving TY=IELP |
| |--------+------------------------------------------------------|
| | V52 | User connected in V5.2 - |
| |--------+------------------------------------------------------|
| | PDE | Priority outgoing line on V5.2 access |
| |--------+------------------------------------------------------|
| | TYQn | Type of equipment connected (0 to 15) |
| | +----+------------------------------------------------------|
| |n =| 0 | Ordinary subscriber (default value) |
| | |----+------------------------------------------------------|
| | | 1 | Test equipment |
| | |----+------------------------------------------------------|
| | | 2 | Operator |
| | |----+------------------------------------------------------|
| | | 3 | Payphone |
| | |----+------------------------------------------------------|
| | | 4 | Data transmission |
| | |----+------------------------------------------------------|
| | | 5 | Interception operator |
| | |----+------------------------------------------------------|
| | | 6 | PABX |
| | |----+------------------------------------------------------|
| | | 7 | Not used |
| | |----+------------------------------------------------------|
| | | 8 | Not used |
| | |----+------------------------------------------------------|
| | | 9 | Not used |
| | |----+------------------------------------------------------|
| | | 10 | Not used |
| | |----+------------------------------------------------------|
| | | | |
| | |----+------------------------------------------------------|
| | | 14 | Not used |
| | |----+------------------------------------------------------|
| | | 15 | Reserved for manufacturer (TKO operator TEST) |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 10/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE : Management of single and grouped lines |
| Digital or analogue subscribers |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| TY = | ESS | Test equipment - specific to France Télécom - |
| | | (equivalent to TYQ1) |
| |--------+------------------------------------------------------|
| | LOP | Carrier line - specific to France Télécom - |
| | | (equivalent to TYQ2) |
| |--------+------------------------------------------------------|
| | PPR | Prepayment set - specific to France Télécom - |
| | | (equivalent TYQ3) |
| |--------+------------------------------------------------------|
| | DMV | Do Not Disturb (centrex) |
| |--------+------------------------------------------------------|
| | SCA | Day-night category change service (centrex) |
| |--------+------------------------------------------------------|
| | UPR | Priority user (centrex without block) |
| |--------+------------------------------------------------------|
| | GABAn | Line test profile |
| | +----+------------------------------------------------------|
| |n =| 0 | Reserved for checking the operation of the tester |
| | |----+------------------------------------------------------|
| | | 1 | Ordinary lines, Payphones, Answering machines, |
| | | | Private installations (default value) |
| | |----+------------------------------------------------------|
| | | 2 | Lines with metering pulse transmission, lines with |
| | | | no concentrator |
| | |----+------------------------------------------------------|
| | | 3 | Long lines |
| | |----+------------------------------------------------------|
| | | 4 | Special lines terminating on low capacity terminals |
| | |----+------------------------------------------------------|
| | | 5 | Lines isolated at the distribution frame |
| | |----+------------------------------------------------------|
| | | 6 | |
| | |----+------------------------------------------------------|
| | | 7 | |
| | |----+------------------------------------------------------|
| | | 8 | |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 11/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE : Management of single and grouped lines |
| Analogue subscriber |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| TY = | FLA | Telephone with recall (flashing) button |
| |--------+------------------------------------------------------|
| | KLA | Keypad subscriber |
| |--------+------------------------------------------------------|
| | SPA | Outgoing only subscriber (termination denied) |
| |--------+------------------------------------------------------|
| | SPB | Incoming only subscriber (origination denied) |
| |--------+------------------------------------------------------|
| | TTX | Line with own premises meter |
| |--------+------------------------------------------------------|
| | TLC | Subscriber connected via a concentrator |
| |--------+------------------------------------------------------|
| | IIB | Inhibition of battery reversal |
| |--------+------------------------------------------------------|
| | DRV | Entitlement to alarm call service |
| | | (used if the FIPAM 'DIR' data item, in record 3, |
| | | is null) |
| |--------+------------------------------------------------------|
| | CAD | Subscriber with dial (default value) |
| |--------+------------------------------------------------------|
| | MIX | Two-way line (default value) |
| |--------+------------------------------------------------------|
| | DSM | Line with message mode signalling |
| |--------+------------------------------------------------------|
| | DTMF | Line with DTMF frequency signalling |
| |--------+------------------------------------------------------|
| | ICR | Inhibition of reduced consumption |
| |--------+------------------------------------------------------|
| | LFL | Faulty line |
| |--------+------------------------------------------------------|
| | TYPOn | Type of operator |
| | +----+------------------------------------------------------|
| |n =| 0 | Implicit value |
| | |----+------------------------------------------------------|
| | | 1 | (not used) |
| | |----+------------------------------------------------------|
| | | 2 | Operator on subscriber set |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 12/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE : Management of single and grouped lines |
| Digital subscriber |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| TY = | VPNE | Virtual Private Networking Extension |
| |--------+------------------------------------------------------|
| | ACT | Activation of CRC4 on the primary access |
| |--------+------------------------------------------------------|
| | EXLS | Exclusive access through signalling link |
| | | (D channel not used) |
| |--------+------------------------------------------------------|
| | INTB | T interface (point to point basic access) |
| |--------+------------------------------------------------------|
| | NBAn | Index for Acces Capacity File ( FIPRO) |
| | | (I -> 1 - 31) |
| |--------+------------------------------------------------------|
| | NCAn | Number n of outgoing B channels (n from 1 to 30) |
| |--------+------------------------------------------------------|
| | NCBn | Number n of incoming B channels (n from 1 to 30) |
| |--------+------------------------------------------------------|
| | PRACi | Protocol handled on the access |
| | +----+------------------------------------------------------|
| |n =| 1 | VN - type access (not ETSI compatible) |
| | |----+------------------------------------------------------|
| | | 2 | VN + type access (ETSI compatible) |
| | |----+------------------------------------------------------|
| | | 3 | ETSI protocol used |
| | |----+------------------------------------------------------|
| | | 4 | reserved |
| |--------+------------------------------------------------------|
| | RR | Repeaters present on the basic access |
| |--------+------------------------------------------------------|
| | PRAD | Primary access directly connected to exchange |
| |--------+------------------------------------------------------|
| | ACPU | Permanent activation of level 1 to U |
| |--------+------------------------------------------------------|
| | ACTU | Temporary activation of level 1 to U |
| |--------+------------------------------------------------------|
| | ACPS | Permanent activation of level 1 to S |
| |--------+------------------------------------------------------|
| | ACP2 | Permanent activation of level 2 to T |
| |--------+------------------------------------------------------|
| | ACT2 | Temporary activation of level 2 to T |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 13/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE : Management of single and grouped lines |
| Digital subscriber |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| | NBLSn | Number n of signalling links (1 to 31) |
| |--------+------------------------------------------------------|
| | LSP | Data link |
| |--------+------------------------------------------------------|
| TY = | NBSn | Number of B channels and type of signalling |
| | +----+------------------------------------------------------|
| |n =| 0 | Not a digital subscriber (default value) |
| | |----+------------------------------------------------------|
| | | 1 | 2B+D base access (ADB), LAPD type signalling |
| | |----+------------------------------------------------------|
| | | 2 | 30B+D primary access (ADP), LAPD type signalling |
| | |-----------------------------------------------------------|
| | | 3 - 7 reserved |
| |---------------------------------------------------------------|
| | CCAi | Category of alarm on primary access |
| | +----+------------------------------------------------------|
| |i =| 1 | Immediate alarm (IM) |
| | |----+------------------------------------------------------|
| | | 2 | Carried over alarm (ID) |
| | |----+------------------------------------------------------|
| | | 3 | reserved |
| | |----+------------------------------------------------------|
| | | 4 | Locked alarm |
| |--------+------------------------------------------------------|
| | TRAMn | Transmision mode and possibly existence |
| | | of a multiplexer |
| | +----+------------------------------------------------------|
| |n =| 0 | Non ISDN equipment |
| | |----+------------------------------------------------------|
| | | 1 | Alternate 2 wires -144 kB/s- without MUXA |
| | |----+------------------------------------------------------|
| | | 2 | 4 wires - 144 kB/s |
| | |----+------------------------------------------------------|
| | | 3 | Echo cancelling - 144 kB/s |
| | |----+------------------------------------------------------|
| | | n | |
| | |----+------------------------------------------------------|
| | | 15 | Unused field which may be reused later |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 14/145 !
+---------------------------------------------------------------------------------+
+----------------------------------------------------------------------+
| |
| (S) TITLE : Management of single and grouped lines |
| Analogue subscriber |
|----------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+---------------------------------------------------|
| TY = | AEMn | Attenuation on transmission |
| | | 0= -1DB , 1= +0DB , 2= +1DB , 3= +2DB |
| |--------+---------------------------------------------------|
| | AREn | Attenuation on reception |
| | | 0= -9dB , 1= -6dB , 2= -7dB , 3= -8dB |
| |--------+---------------------------------------------------|
| | EQCn | Switchable equalization : 0 = 2 x 150 |
| | | 1 = 2 x 250 |
| | | 2 = 2 x 400 |
| | | 3 = 2 x 600 |
| |--------+---------------------------------------------------|
| | LCLi | Limitation of line current (i = 1 to 3) |
| | | (by default LCL0) |
+----------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 15/145 !
+---------------------------------------------------------------------------------+
+----------------------------------------------------------------------}
| |
| (P) TITLE : Management of single and grouped lines |
| Digital or analogue subscriber |
|----------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+---------------------------------------------------|
| TY = | DQ1 | |
| |--------+---------------------------------------------------|
| | DQ2 | Battery reversal metering pulses |
| |--------+---------------------------------------------------|
| | DQ3 | Display IDR systematic |
| |--------+---------------------------------------------------|
| | DQBn | Standard discrimination field (0 to 7) |
| | +----+---------------------------------------------------|
| |n =| 0 | |
| | |----+---------------------------------------------------|
| | | 1 | |
| | |----+---------------------------------------------------|
| | | 2 | |
| | |----+---------------------------------------------------|
| | | 3 | |
| | |----+---------------------------------------------------|
| | | 4 | |
| | |----+---------------------------------------------------|
| | | 5 | |
| | |----+---------------------------------------------------|
| | | 6 | |
| | |----+---------------------------------------------------|
| | | 7 | |
+----------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 16/145 !
+---------------------------------------------------------------------------------+
+----------------------------------------------------------------------}
| |
| (P) TITLE : Management of single and grouped lines |
| Digital or analogue subscriber |
|----------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+---------------------------------------------------|
| | DQAn | Standard discrimination field (0 to 7) |
| | +----+---------------------------------------------------|
| |n =| 0 | |
| | |----+---------------------------------------------------|
| | | 1 | |
| | |----+---------------------------------------------------|
| | | 2 | |
| | |----+---------------------------------------------------|
| | | 3 | |
| | |----+---------------------------------------------------|
| | | 4 | |
| | |----+---------------------------------------------------|
| | | 5 | |
| | |----+---------------------------------------------------|
| | | 6 | |
| | |----+---------------------------------------------------|
| | | 7 | |
| | |----+---------------------------------------------------|
| | | 8 | |
| | |----+---------------------------------------------------|
| | | 9 | |
| | |----+---------------------------------------------------|
| | | 10 | |
| | |----+---------------------------------------------------|
| | | 11 | |
| | |----+---------------------------------------------------|
| | | 12 | |
| | |----+---------------------------------------------------|
| | | 13 | |
| | |----+---------------------------------------------------|
| | | 14 | |
| | |----+---------------------------------------------------|
| | | 15 | |
+----------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 17/145 !
+---------------------------------------------------------------------------------+
+--------------------------------------------------------------------+
| |
| (A) TITLE : Management of single and grouped lines |
| Digital or analogue subscribers |
|--------------------------------------------------------------------|
| Parameter | |
|---------------------| MEANING |
| Symbol | Value | |
|---------+-----------+----------------------------------------------|
| TY = | SRn | Call barring (0 to 15) |
| | +-----+----------------------------------------------|
| | n = | 0 | Available |
| | |-----+----------------------------------------------|
| | | 1 | Available |
| | |-----+----------------------------------------------|
| | | 2 | Available |
| | |-----+----------------------------------------------|
| | | 3 | Available |
| | |-----+----------------------------------------------|
| | | 4 | Available |
| | |-----+----------------------------------------------|
| | | 5 | Available |
| | |-----+----------------------------------------------|
| | | 6 | Available |
| | |-----+----------------------------------------------|
| | | 7 | Available |
| | |-----+----------------------------------------------|
| | | 8 | Available |
| | |-----+----------------------------------------------|
| | | 9 | Available |
| | |-----+----------------------------------------------|
| | | 10 | Available |
| | |-----+----------------------------------------------|
| | | 11 | Available |
| | |-----+----------------------------------------------|
| | | 12 | Available |
| | |-----+----------------------------------------------|
| | | 13 | Available |
| | |-----+----------------------------------------------|
| | | 14 | Available |
| | |-----+----------------------------------------------|
| | | 15 | Available |
+--------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 18/145 !
+---------------------------------------------------------------------------------+
+--------------------------------------------------------------------+
| |
| (A) TITLE: CENTREX - Centrex subscriber management |
| |
|--------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Name | Value | |
|---------+--------+-------------------------------------------------|
| TY = | SRNn | Night restricted service category |
| | +----+-------------------------------------------------|
| |n =| 0 | Free |
| | |----+-------------------------------------------------|
| | | 1 | Free |
| | |----+-------------------------------------------------|
| | | 2 | Free |
| | |----+-------------------------------------------------|
| | | 3 | Free |
| | |----+-------------------------------------------------|
| | | | |
| . . . |
| . . . |
| | | | |
| | |----+-------------------------------------------------|
| | | 15 | Free |
+--------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 19/145 !
+---------------------------------------------------------------------------------+
1.4 CATEGORY PARAMETERS (x)

+-------------------------------------------------------------------------+
| |
| (S) TITLE : Management of single and grouped lines |
| Digital or analogue subscribers |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CAT = | APE | Incoming calls into CUG allowed |
| |--------+------------------------------------------------------|
| | APS | Outgoing calls from CUG allowed |
| |--------+------------------------------------------------------|
| | COF | Conference call between 3 subscribers (entitlement |
| | | to TYP service) |
| |--------+------------------------------------------------------|
| | COLR | Entitlement to Connected Line Identification |
| | | Restriction |
| |--------+------------------------------------------------------|
| | DEA | Authorisation for details of incoming calls |
| |--------+------------------------------------------------------|
| | DNR | Call forwarding if no answer |
| |--------+------------------------------------------------------|
| | IAMT | Actions on temporary mode prohibited |
| |--------+------------------------------------------------------|
| | IDB | Entitlement to Subscriber C to receive |
| | | Subscriber B's identity |
| |--------+------------------------------------------------------|
| | LNP | Non preferential line |
| |--------+------------------------------------------------------|
| | LST | No charging of calling party |
| |--------+------------------------------------------------------|
| | OSID | Entitlement to get beyond the Connected Line |
| | | Identification Restriction requested by subscriber |
| |--------+------------------------------------------------------|
| | SIDR | Entitlement to keep the Connected Line |
| | | Identification Restriction |
| |--------+------------------------------------------------------|
| | RAIN | Call forwarding on international number allowed |
| |--------+------------------------------------------------------|
| | RVO | Call forwarding if busy state |
| |--------+------------------------------------------------------|
| | RVT | Call forwarding |
| |--------+------------------------------------------------------|
| | RAA | Access restriction on incoming Transgroupe calls |
| | | only |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 20/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE: Management of single and grouped lines |
| Digital or analogue subscribers |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Sumbol | Value | |
|---------+--------+------------------------------------------------------|
| CAT = | ISTA | Transporter selection on a call-by-call basis |
| | | prohibited |
| |--------+------------------------------------------------------|
| | IXn | 3-digit index to be added to the start of the |
| | | transgroup numbering (n = 001 - 999) |
| |--------+------------------------------------------------------|
| | SIRV | Non disclosure of identity of B to C if forward |
| | | from A to C |
| |--------+------------------------------------------------------|
| | DPND | Calling party name presentation authorisation |
| | | (prohibited for centrex subscribers, PCM subscribers |
| | | SPA lines and VN ISDN accesses) |
| |--------+------------------------------------------------------|
| | INSPn | Insertion/substitution of digits in preanalysis |
| | +----+------------------------------------------------------|
| |n =| 0 | No insertion (default value) |
| | |----+------------------------------------------------------|
| | | 1 | Insertion before preanalysis of the INDR digits |
| | |----+------------------------------------------------------|
| | | 2 | Insertion after preanalysis of the INDR digits in |
| | | | the RCE row (given by the preanalysis file) if the |
| | | | INS discrimination (given by the preanalysis file) |
| | | | is also present. The presence of this discrimination |
| | | | also enables a specific preanalysis file defined |
| | | | by the FIPAM data: PREAAI to be used |
| |--------+------------------------------------------------------|
| | NLAn | Right to n collective lists of 10 abbreviated nos. |
| | | n = 1 to 1023 (for centrex subscriber only) |
| |--------+------------------------------------------------------|
| | NLBn | Right to n collective lists of 100 abbreviated nos. |
| | | n = 1 to 511 (for centrex subscribers only) |
| |--------+------------------------------------------------------|
| | POC | Operator position (for centrex subscriber only) |
| |--------+------------------------------------------------------|
| | PRV | Right to protection against forwards |
| | | (for centrex subscriber only) |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 21/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE: Management of single and grouped lines |
| Digital or analogue subscribers |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CAT = | DROC | Right to callback busy subscriber |
| |--------+------------------------------------------------------|
| | ICL | Local service command prohibition |
| |--------+------------------------------------------------------|
| | SRC | Restricted service commanded by subscriber |
| |--------+------------------------------------------------------|
| | SIRA | Notification- secret backward forward identity |
| | | 0 = notification with forward number |
| | | 1 = notification without number |
| | | 2 = no notification |
| |--------+------------------------------------------------------|
| | ACRJ | Right to ACR (Anonymous Call Rejection) service |
| |--------+------------------------------------------------------|
| | ECT | Right to call transfer |
| |--------+------------------------------------------------------|
| | ECTI | Right to transfer call to international |
| |--------+------------------------------------------------------|
| | SNI | Immediate announcement of message forbidden |
| |--------+------------------------------------------------------|
| | SND | Delayed announcement of message forbidden |
| |--------+------------------------------------------------------|
| | AMTRA | Right to modify carrier numbers for A traffic |
| |--------+------------------------------------------------------|
| | AMTRB | Right to modify carrier numbers for B traffic |
| |--------+------------------------------------------------------|
| | AMTRC | Right to modify carrier numbers for C traffic |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 22/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE : Management of single and grouped lines |
| Digital or analogue subscribers |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CAT = | RSI | Call forwarding on OP if called busy |
| |--------+------------------------------------------------------|
| | IROC | Right to ROC forbidden (R23G10 only) |
| |--------+------------------------------------------------------|
| | DIPA | Entitlement to Connected Line Identification in |
| | | call phase |
| |--------+------------------------------------------------------|
| | ISA | Prohibition of Secret Call by Call |
| |--------+------------------------------------------------------|
| | ASA | Authorisation of Secret Call by Call |
| |--------+------------------------------------------------------|
| | AAMT | Authorisation of the modification of the temporary |
| | | Secret Call by Call |
| |--------+------------------------------------------------------|
| | DFA | Right to filtering of incoming calls |
| |--------+------------------------------------------------------|
| | RFNR | Fixed call forwarding on no answer |
| |--------+------------------------------------------------------|
| | RVFO | Fixed call forwarding on occupation |
| |--------+------------------------------------------------------|
| | RVFT | Fixed call forwarding inconditional |
| |--------+------------------------------------------------------|
| | IAM | Entitlement to Connected Line Indentification |
| | | Presentation |
| | | (validated by CAMn) |
| |--------+------------------------------------------------------|
| | CAMn | Malicious calls category |
| | +----+------------------------------------------------------|
| |n =| 1 | Subscriber controlled MCID without holding |
| | |----+------------------------------------------------------|
| | | 2 | Automatic MCID without holding |
| | |----+------------------------------------------------------|
| | | 3 | Subscriber controlled MCID with holding |
| | |----+------------------------------------------------------|
| | | 4 | Automatic MCID with holding |
| | |----+------------------------------------------------------|
| | | 5 | Not used |
| | |----+------------------------------------------------------|
| | | 6 | Not used |
| | |----+------------------------------------------------------|
| | | 7 | Not used |
| | |----+------------------------------------------------------|
| | | 8 | Not used |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 23/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE : Management of single and grouped lines |
| Digital or analogue subscribers |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CAT = | DCIn | Right to n digit charge allocation code after |
| | | dialling |
| |--------+------------------------------------------------------|
| | CFAn | |
| | +----+------------------------------------------------------|
| |n =| 1 | Catastrophe facility level 1 |
| | |----+------------------------------------------------------|
| | | 2 | Catastrophe facility level 2 |
| | |----+------------------------------------------------------|
| | | 3 | Catastrophe facility level 3 |
| |--------+------------------------------------------------------|
| | NATn | Type of subscriber field |
| | +----+------------------------------------------------------|
| |n =| 0 | Analogue subscriber (default value) |
| | |----+------------------------------------------------------|
| | | 1 | Not used |
| | |----+------------------------------------------------------|
| | | 2 | ISDN subscriber |
| | |----+------------------------------------------------------|
| | | 3 | Not used |
| | |----+------------------------------------------------------|
| | | 4 | Not used |
| | |----+------------------------------------------------------|
| | | | |
| | | | |
| | |----+------------------------------------------------------|
| | | 15 | Not used |
| |--------+------------------------------------------------------|
| | CABi | Subscriber category as called party |
| | +----+------------------------------------------------------|
| |i =| 1 | Incoming call forbidden out of International OP |
| | |----+------------------------------------------------------|
| | | 2 | International incoming call forbidden |
| | |----+------------------------------------------------------|
| | | 3 | |
| | |----+------------------------------------------------------|
| | | 4 | |
| | |----+------------------------------------------------------|
| | | | |
| | | | |
| | |----+------------------------------------------------------|
| | | 63 | |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 24/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE : Management of single and grouped lines |
| Analogue subscriber |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CAT = | AAB | Entitlement to absent subscriber service |
| |--------+------------------------------------------------------|
| | AEN | Recorded call |
| |--------+------------------------------------------------------|
| | ANS | Subscriber not rung |
| |--------+------------------------------------------------------|
| | DAC | Entitlement to hold for enquiry service |
| |--------+------------------------------------------------------|
| | DND | Entitlement to 'DO NOT DISTURB' service |
| |--------+------------------------------------------------------|
| | IAI | Call waiting indication |
| |--------+------------------------------------------------------|
| | IDT | Immediate charging indication |
| |--------+------------------------------------------------------|
| | INT | Entitlement to incoming call interception by an |
| | | operator on a subscriber line |
| |--------+------------------------------------------------------|
| | LAI | Hotline (immediate) |
| |--------+------------------------------------------------------|
| | LAT | Hotline (time-delay) |
| |--------+------------------------------------------------------|
| | NMU | No entitlement to re-answer |
| |--------+------------------------------------------------------|
| | PIN | Subscriber protected against intrusions |
| |--------+------------------------------------------------------|
| | RDA | Entitlement to call back calling party |
| |--------+------------------------------------------------------|
| | SRS | Automatic call back to busy number (local call) |
| |--------+------------------------------------------------------|
| | SVO | Entitlement to call local server |
| |--------+------------------------------------------------------|
| | IDAI | Entitlement to Connected Line Identification in IAI |
| | | phase |
| |--------+------------------------------------------------------|
| | SONi | Number of the ringing pattern associated with the |
| | | subscriber number ( i = 0-3 ). |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 25/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE : Management of single and grouped lines |
| Analogue subscriber |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CAT = | FIE | Right to be filtered (centrex only) |
| |--------+------------------------------------------------------|
| | FIR | Right to be filtering (centrex only) |
| |--------+------------------------------------------------------|
| | GIAn | Call intercept group n = 1 to 4095 |
| | | (centrex only) |
| |--------+------------------------------------------------------|
| | RAL | Right to local automatic callback |
| | | (centrex only) |
| |--------+------------------------------------------------------|
| | LATF | Fixed timed routing line (fixed Hot line) |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 26/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE : Management of single and grouped lines |
| Digital subscriber |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CAT = | TTXN | Metering pulse retransmission |
| |--------+------------------------------------------------------|
| | IDC | Total cost indication |
| |--------+------------------------------------------------------|
| | RVTI | Entitlement to internal call forwarding |
| |--------+------------------------------------------------------|
| | DMG | Entitlement to consultation call |
| |--------+------------------------------------------------------|
| | DIU | Entitlement to user to user information |
| |--------+------------------------------------------------------|
| | DIU2 | Entitlement to SUU2 |
| |--------+------------------------------------------------------|
| | CLABn | Subscription class |
| | +----+------------------------------------------------------|
| |n =| 0 | Analogue (default value) |
| | |----+------------------------------------------------------|
| | | 1 | Voice + 3.1kHz audio (CCBNT+SSC) |
| | |----+------------------------------------------------------|
| | | 2 | Voice + 3.1kHz audio + 64kB/s (CCBNT+SSC+CCBT) |
| | |----+------------------------------------------------------|
| | | 3 | 64kB/s + virtual circuit (CCBT+CV+ SSC) |
| | |----+------------------------------------------------------|
| | | 4 | ISDN (ISDN) |
| | |----+------------------------------------------------------|
| | | 5 | |
| | |----+------------------------------------------------------|
| | | 6 | |
| | |----+------------------------------------------------------|
| | | 7 | |
| |--------+------------------------------------------------------|
| | GFU | Entitlement to belong to CUGs (Closed User Groups) |
| |--------+------------------------------------------------------+
| | GPRF | Entitlement to preferential CUG |
| |--------+------------------------------------------------------|
| | COLP | Entitlement to Connected Line Identification |
| | | Presentation |
| |--------+------------------------------------------------------|
| | AIDR | Special arrangement of the number (CLIP) |
+-------------------------------------------------------------------------+

*SSC - Service without connection

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 27/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE: Management of single and grouped lines |
| Digital subscriber |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+---------------------------------------------------------------|
| CAT = | RSn Restriction of calls to NDS (0 to 15) |
| | +---------------------------------------------------------|
| | n = | 0 | Available |
| | |-----+---------------------------------------------------|
| | | 1 | Available |
| | |-----+---------------------------------------------------|
| | | 2 | Available |
| | |-----+---------------------------------------------------|
| | | 3 | Available |
| | |-----+---------------------------------------------------|
| | | 4 | Available |
| | |-----+---------------------------------------------------|
| | | 5 | Available |
| | |-----+---------------------------------------------------|
| | | 6 | Available |
| | |-----+---------------------------------------------------|
| | | 7 | Available |
| | |-----+---------------------------------------------------|
| | | 8 | Available |
| | |-----+---------------------------------------------------|
| | | 9 | Available |
| | |-----+---------------------------------------------------|
| | | 10 | Available |
| | |-----+---------------------------------------------------|
| | | 11 | Available |
| | |-----+---------------------------------------------------|
| | | 12 | Available |
| | |-----+---------------------------------------------------|
| | | 13 | Available |
| | |-----+---------------------------------------------------|
| | | 14 | Available |
| | |-----+---------------------------------------------------|
| | | 15 | Available |
|---------+---------------------------------------------------------------|
| CAT = | ORAS | Callback option |
| |--------+------------------------------------------------------|
| | SPN | Service By Number (service offer by NDS) |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 28/145 !
+---------------------------------------------------------------------------------+
+----------------------------------------------------------------------}
| (P) TITLE : Management of single and grouped lines |
| Digital or analogue subscribers |
|----------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
| | | |
|---------+--------+---------------------------------------------------|
| CAT = | DA1 | |
| |--------+---------------------------------------------------|
| | DAAn | Standard discriminations 1<n<15 |
| | +----+---------------------------------------------------|
| |p =| 1 | Test subscriber for VN5/VN6 |
| | |----+---------------------------------------------------|
| | | 2 | Assistance operatrice |
| | |----+---------------------------------------------------|
| | | 4 | IDT systematique |
| | |----+---------------------------------------------------|
| | | 8 | Subscriber with unsaid bill |
|---------+--------+---------------------------------------------------|
| CAT = | DABn | Standard discriminations 1<n<3 |
| | +----+---------------------------------------------------|
| |p =| 1 | NDS notsending SEL2824 |
| | |----+---------------------------------------------------|
| | | 2 | V5.2 Wireless local loop mobility |
| |--------+---------------------------------------------------|
| | DADn | Standard discriminations 1<n<15 |
| | +----+---------------------------------------------------|
| |p =| 1 | Subscriber VPN1 |
| | |----+---------------------------------------------------|
| | | 2 | Subscriber VPN2 |
| | |----+---------------------------------------------------|
| | | 4 | |
| | |----+---------------------------------------------------|
| | | 8 | |
+----------------------------------------------------------------------+

| DAAn | | DABn | | DADn |


| p | | p | | p |
| 8 4 2 1 | | 2 1 | | 8 4 2 1 |
+---------------+ +-------+ +---------------+
n discri -> ex DAAn 1<n<15
CAT=DAA5 => DAA1+DAA4

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 29/145 !
+---------------------------------------------------------------------------------+
+-----------------------------------------------------------------+
| |
| (A) TITLE : Management of single and grouped lines |
| Digital or analogue subscribers |
|-----------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+----------------------------------------------|
| CAT = | FDn | Entitlement to and category of detailed |
| | 0-n-7 | billing |
| |--------+----------------------------------------------|
| | CTn | Routing and charging category |
| | 0-n-32 | -Used to build the CIA1 in analysis |
| | | indexation |
| | | -Used in cases where TNX(FIPAM)= 1 |
| |--------+----------------------------------------------|
| | CACn | Routing category |
| | 0-n-64 | 0<MXCAC(FIPAM)<64 |
| | | -Used in cases where TNX(FIPAM)= 0 |
| |--------+----------------------------------------------|
| | CAXn | Charging category |
| | | 0<MXCAX(FIPAM)<64 |
| | 0-n-64 | -Used in cases where TNX(FIPAM)= 0 |
| |--------+----------------------------------------------|
| | ZGn | Calling party geographic area |
| | | Default value = 1 |
| |0-n-255 | 0<MXZG(FIPAM)<255 |
| |--------+----------------------------------------------|
| | ZTXn | Charging area associated with the calling |
| | | Default value = 1 |
| | 0-n-128| 0<MXZTX(FIPAM)<128 |
| |--------+----------------------------------------------|
| | DFn | Diversion to forwarded number (1 to 30) |
| | 0-n-31 | party (1 to 31) |
| |--------+----------------------------------------------|
| | NAn | Abbreviated dialling |
| | | (only for analogue subscribers) |
| | 1-n-16 | n = number of groups of 5 numbers |
| |--------+----------------------------------------------|
| | SRAi | Incoming call barring |
| | 1-i-15 | |
| |--------+----------------------------------------------|
| | CRIn | Intelligent Network Category |
| | 1-n-32 | (1 to 32) |
+-----------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 30/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (A) RUBRIC: Management of single and grouped lines |
| Digital or analog subscriber |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CAT = | TRAi | Transporter number for traffic A |
| | | 1 | i | 9999 |
| | | The maximum number of digits in the transporter |
| | | number is given by the field FIPAM NBSTR |
| | | Record 52 |
| |--------+------------------------------------------------------|
| | TRBj | Transporter number for traffic B |
| | | 1 | j | 9999 |
| | | The maximum number of digits in the transporter |
| | | number is given by the field FIPAM NBSTR |
| | | Record 52 |
| |--------+------------------------------------------------------|
| | TRCk | Transporter number for traffic C |
| | | 1 | k | 9999 |
| | | The maximum number of digits in the transporter |
| | | number is given by the field FIPAM NBSTR |
| | | Record 52 |
| |--------+------------------------------------------------------|
| | ZLTi | Local sort area number allocated to the subscriber |
| | | 1 | i | 64, 1 is the default value |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 31/145 !
+---------------------------------------------------------------------------------+
+--------------------------------------------------------------------+
| |
| (A) TITLE: CENTREX - Centrex subscriber management |
| |
|--------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Name | Value | |
|---------+--------+-------------------------------------------------|
| CAT = | SREn | Restricted called service category |
| | +----+-------------------------------------------------|
| |n =| 0 | No restriction terminating |
| | |----+-------------------------------------------------|
| | | 1 | Call from public network prohibited |
| | |----+-------------------------------------------------|
| | | 2 | |
| | |----+-------------------------------------------------|
| | | 3 | |
| | |----+-------------------------------------------------|
| | | | |
| | | | |
| | |----+-------------------------------------------------|
| | | 15 | |
+--------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 32/145 !
+---------------------------------------------------------------------------------+
1.5 COMPANY PARAMETERS (CENTREX) (x)

+--------------------------------------------------------------------+
| |
| (S) TITLE: CENTREX - Company management |
| |
|--------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Name | Value | |
|---------+--------+-------------------------------------------------|
| NSOC = | charac.| CENTREX name of the company |
| | | (1-->8 characters) |
|---------+--------+-------------------------------------------------|
| SOC = |1 - 1023| Company number if private subscriber |
| | | |
|---------+--------+-------------------------------------------------|
| LNU = | | Length of the internal numbering |
| | 5 - 11 | (1) Centrex without block. |
| | 2 - 4 | (2) Centrex with blocks. |
|---------+--------+-------------------------------------------------|
| TRN = | 1 - 10 | Number of the numbering block |
| (2) | | |
|---------+--------+-------------------------------------------------|
| TRL = |0 - 1000| Length of the numbering block |
| (2) | | |
|---------+--------+-------------------------------------------------|
| TRND = | ND | Block start designation number |
| (2) | | |
|---------+--------+-------------------------------------------------|
| NOP = | ND | Operator designation number |
| | | |
|---------+--------+-------------------------------------------------|
| NARN = | ND | Night forwarding designation number. |
| | | Compulsory if CAT=RNU |
+--------------------------------------------------------------------+

(1) Centrex without blocks. (2) Centrex with blocks.

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 33/145 !
+---------------------------------------------------------------------------------+
+--------------------------------------------------------------------+
| |
| (S) TITLE: CENTREX - Company management |
| |
|--------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Name | Value | |
|---------+--------+-------------------------------------------------|
| CAT = | RNU | Night forwarding if OP pool closed |
| | | (NARN valid) |
| |--------+-------------------------------------------------|
| | RNR | Forward to OP if no response to a terminating |
| | | call from the public network |
| |--------+-------------------------------------------------|
| | RSO | Forward to OP if busy for a terminating call |
| | | from the public network |
| |--------+-------------------------------------------------|
| | ASO | Camp on busy for terminating call from the |
| | | public network |
| |--------+-------------------------------------------------|
| | ASI | Camp on busy for terminating call from the |
| | (1) | company's private network |
| |--------+-------------------------------------------------|
| | RSI | Forward to OP if busy for a terminating call |
| | (1) | from the company's private network |
| |--------+-------------------------------------------------|
| | RNI | Forward to OP if no response for a terminating |
| | (1) | call from the company's private network |
+--------------------------------------------------------------------+

(1) Centrex without blocks

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 34/145 !
+---------------------------------------------------------------------------------+
+--------------------------------------------------------------------+
| |
| (A) TITLE: CENTREX - Company management |
| |
|--------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Name | Value | |
|---------+--------+-------------------------------------------------|
| TY = | SRn | Call barring (0 to15) |
| | +----+-------------------------------------------------|
| |n =| 0 | Available |
| | |----+-------------------------------------------------|
| | | 1 | Available |
| | |----+-------------------------------------------------|
| | | 2 | Available |
| | |----+-------------------------------------------------|
| | | 3 | Available |
| | |----+-------------------------------------------------|
| | | 4 | Available |
| | |----+-------------------------------------------------|
| | | 5 | Available |
| | |----+-------------------------------------------------|
| | | | |
| . . . |
| . . . |
| | | | |
| | |----+-------------------------------------------------|
| | | 15 | Available |
+--------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 35/145 !
+---------------------------------------------------------------------------------+
+--------------------------------------------------------------------}
| |
| (P) TITLE: CENTREX - Company management |
| |
|--------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Name | Value | |
|---------+--------+-------------------------------------------------|
| | | |
| CAT = | DSi | Non-specific company discrimination. |
| | | |
| | +----+-------------------------------------------------|
| |i =| 1 | Not used |
| | |----+-------------------------------------------------|
| | | 2 | Not used |
| | |----+-------------------------------------------------|
| | | 3 | Not used |
| | |----+-------------------------------------------------|
| | | 4 | Not used |
| | |----+-------------------------------------------------|
| | | 5 | Not used |
| | |----+-------------------------------------------------|
| | | 6 | Not used |
| | |----+-------------------------------------------------|
| | | 7 | Not used |
| | |----+-------------------------------------------------|
| | | 8 | Not used |
+--------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 36/145 !
+---------------------------------------------------------------------------------+
2 ADDRESS INFORMATION MANAGEMENT (x)

2.1 PRE-ANALYSIS (x)

+-------------------------------------------------------------------------+
| |
| (S) TITLE : Pre-analysis - Interpretation of the parameters |
| |
|-------------------------------------------------------------------------|
| Parameter | | |
|------------------| TYPRE | MEANING |
| Symbol | Value | | |
|---------+--------+-------+----------------------------------------------|
| | | 1 | Continue pre-analysis in the same file |
| | | 2 | Continue in another pre-analysis file |
| | | 3 | End of pre-analysis with recognition of TRAD |
| | | 4 | End of pre-analysis with recognition of a |
| | | | non chargeable facility |
|---------+--------+-------+----------------------------------------------|
| PREA = | 1-15 | All | Pre-analysis file number |
|---------+--------+-------+----------------------------------------------|
| PRE = | 1-8 | All | Access or routing code to be pre-analysed |
|---------+--------+-------+----------------------------------------------|
| TONI = | 1-15 | All | Tone to be transmitted to the calling party |
|---------+--------+-------+----------------------------------------------|
| RCA = | 1-15 | 1, 2 | Number of digits required before continuing |
| | | | pre-analysis or analysis with the TRAD number|
| | | | RCA is translated into RCAT or RCAN in the |
| | | | files. |
|---------+--------+-------+----------------------------------------------|
| PRES = | 1-15 | 2 | Change pre-analysis file to PRES to continue |
| | | | the analysis |
|---------+--------+-------+----------------------------------------------|
| CHA = | 1-8 | 2, 3 | Digits to be substituted for the |
| | | | pre-analyzed number |
|---------+--------+-------+----------------------------------------------|
| RCE = | 1-15 | 2, 3 | If CHAi=0: rank of the digit at which |
| | | | pre-analysis or analysis starts |
| (1) | | | IF CHAi>0: rank of the digit in front of |
| | | | which the CHAi digits should be added. |
| | | | In the files, RCE is translated into: |
| | | | >RCEA if the TRAD parameter is present, |
| | | | >RCEP if the PRES parameter is present. |
+-------------------------------------------------------------------------+

(1) In order to realise the progres of analyse (or digits-insertion) on the


pre-analysis digits identified, RCE must be inférior or équal to the number
of digits of the pre-analyzed préfix number +1.

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 37/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE : Pre-analysis - Interpretation of the parameters |
| |
|-------------------------------------------------------------------------|
| Parameter | | |
|------------------| TYPRE | MEANING |
| Symbol | Value | | |
|---------+--------+-------+----------------------------------------------|
| TRAD = | 1-15 | 3 | TRAD file number in which the |
| | | | analysis should start. |
|---------+--------+-------+----------------------------------------------|
| ASS = | 1-4095 | 3 | Routing number to SSCS server IN-CS1 |
| | | | |
|---------+--------+-------+----------------------------------------------|
| TYFAC = | | 4 | Type of facility (=> TYFA-TYPU) |
| TYFA | 1-31 | | TYFA = TYpe of FAcility, |
| TYPU | 1-15 | | TYPU = TYPe of Usage (enable - check use - |
| | | | disable) |
|---------+--------+-------+----------------------------------------------|
| NUI = | 0-3 | 3 | Emergency service number |
| | | | |
|---------+--------+-------+----------------------------------------------|
| CUR = | 1-10 | 3 | Emergency service routing code |
| | digits | | |
|---------+--------+-------+----------------------------------------------|
| NPREF = | 0-5 | 3 | Access code for the CSN |
| | | | |
|---------+--------+-------+----------------------------------------------|
| TYPRF = | | 3 | Class and type of access code for the CSN |
| | 1-15 | | Class |
| | 1-15 | | Type |
|---------+--------+-------+----------------------------------------------|
| CHP = | 1-8 | 3 | : Preanalysis prefix digits for the CSN |
| | digits | | |
|---------+--------+------------------------------------------------------|
| MAR | OBP | Permanent observation mark |
| | | |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 38/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE : Pre-analysis - Interpretation of the parameters |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| DIS | APU | Call presumed urgent |
| |--------+------------------------------------------------------|
| | SYK | Keypad syntax facility |
| |--------+------------------------------------------------------|
| | PID | IDT prefix |
| |--------+------------------------------------------------------|
| | INZ | Area code insertion |
| |--------+------------------------------------------------------|
| | PSI | Secret call by call identity prefix |
| |--------+------------------------------------------------------|
| | MTI | International transit code |
| |--------+------------------------------------------------------|
| | RA | A preanalysis which carries DIS=RA will guide the |
| | | preanalysis of a subscriber with CAT=TRAi to a |
| | | transporter preanalysis |
| |--------+------------------------------------------------------|
| | RB | A preanalysis which carries DIS=RB will guide the |
| | | preanalysis of a subscriber with CAT=TRAi to a |
| | | transporter preanalysis |
| |--------+------------------------------------------------------|
| | RC | A preanalysis which carries DIS=RC will guide the |
| | | preanalysis of a subscriber with CAT=TRCi to a |
| | | transporter preanalysis |
| |--------+------------------------------------------------------|
| | INS | Insertion of the code associated with the subscriber |
| | | or the circuit group |
| |--------+------------------------------------------------------|
| | ISTA | Prohibition for the selection of the transporter on |
| | | a call by call basis |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 39/145 !
+---------------------------------------------------------------------------------+
+------------------------------------------------------------------------}
| |
| (P) TITLE : PRE-ANALYSIS RC / NPREA RELATIONSHIPS |
| |
|------------------------------------------------------------------------|
| Pre- | Register code and VSG associated with a pre-analysis file |
| analysis | number |
| number | |
|------------+-----------------------------------------------------------|
| 1 | CSE Reveil Subscriber / Call subscriber INSP2 |
|------------+-----------------------------------------------------------|
| 2 | Q421 mixte/R2 INT CCITT / Call trunk INSP2 |
|------------+-----------------------------------------------------------|
| 3 | Q421 mixte/Decadic |
|------------+-----------------------------------------------------------|
| 4 | |
|------------+-----------------------------------------------------------|
| 5 | |
|------------+-----------------------------------------------------------|
| 6 | |
|------------+-----------------------------------------------------------|
| 7 | |
|------------+-----------------------------------------------------------|
| 8 | ISUP V2 Inde Boucle |
|------------+-----------------------------------------------------------|
| 9 | IN-ER1 |
|------------+-----------------------------------------------------------|
| 10 | CLI for multi SCP IN CS1 or IN ER1 |
| | ACH depend to CLI |
|------------+-----------------------------------------------------------|
| 11 | Multi carrier |
|------------+-----------------------------------------------------------|
| 12 | ISUP V2 Inde / IP / ROC |
|------------+-----------------------------------------------------------|
| 13 | VPN |
|------------+-----------------------------------------------------------|
| 14 | Centrex |
|------------+-----------------------------------------------------------|
| 15 | IN-CS1 |
+------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 40/145 !
+---------------------------------------------------------------------------------+
+------------------------------------------------------------------------}
| |
| (P) TITLE : Pre-analysis - Interpretation of the parameters |
| |
|------------------------------------------------------------------------|
| Parameter | |
|--------------------------| MEANING |
| Symbol | Value | |
|---------+----------------+---------------------------------------------|
| DIS | DPi | NPREA | Name |
| | i = 1-7 | | |
| |----------------+-------+-------------------------------------|
| | DP1 | | Enable notification |
| |----------------+-------+-------------------------------------|
| | DP2 | | Disable notification |
| |----------------+-------+-------------------------------------|
| | DP3 | | Assistance operator call |
| |----------------+-------+-------------------------------------|
| | DP4 | | Rivate prefix to be supresed |
| |----------------+-------+-------------------------------------|
| | DP5 | | |
| |----------------+-------+-------------------------------------|
| | DP6 | | |
| |----------------+-------+-------------------------------------|
| | DP7 | | Calling identification request |
+------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 41/145 !
+---------------------------------------------------------------------------------+
2.2 ANALYSIS (x)

+-------------------------------------------------------------------------+
| |
| (S) TITLE : Analysis |
| |
|-------------------------------------------------------------------------|
|Symbol| Value | |
|------+----------+-------------------------------------------------------|
| TRAD | 1-15 | Number of the address analysis processor (TR) |
|------+----------+-------------------------------------------------------|
| IND | 1-16 | Area code analysed in the specified TR |
|------+----------+-------------------------------------------------------|
| INDA | 1-16 | Equivalent area code already used |
|------+----------+-------------------------------------------------------|
| RDC | 1-31 | Number of digits to be received in closed numbering |
|------+----------+-------------------------------------------------------|
| RCMI | 1-31 | Minimum number of digits to be received in open |
| | | numbering |
|------+----------+-------------------------------------------------------|
| RCMA | 1-31 | Maximum number of digits to be received in open |
| | | numbering |
|------+----------+-------------------------------------------------------|
|------+----------+-------------------------------------------------------|
| MOD | A or N | Can be used in transitory mode (TNX=2/3 in FIPAM) |
|-----------------+-------------------------------------------------------|
| MOD = A | Indexation method TNX(FIPAM)=1 |
|-----------------+-------------------------------------------------------|
| ACHN | X-i | Routing number (X) for the CIA1 routing category |
| | | designated (i) |
| | | 1<i<CIA1 Max (CTMACH of FIPAM) |
|------+----------+-------------------------------------------------------|
| PTXN | Y-j | Number of the charging parameter (Y) associated with |
| | | the CIX1 charging category designated (j) |
| | | 1<j<CIX1 Max (CTMPTX of FIPAM) |
|-----------------+-------------------------------------------------------|
| MOD = N | Indexation method TNX(FIPAM)=0 |
|-----------------+-------------------------------------------------------|
| ACHN | X-i | Routing number (X) for the CAC routing category |
| | | designated (i) |
| | | 1<i<CAC Max (MXCAC of FIPAM) |
|------+----------+-------------------------------------------------------|
| PTXN | Y-j | Number of the charging parameter (Y) associated with |
| | | the ZTX charging category designated (j) |
| | | 1<j<ZTX Max (MXZTX of FIPAM) |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 42/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE : Analysis |
| |
|-------------------------------------------------------------------------|
| Cmd parameter | |
|-----------------| MEANING |
|Symbol| Value | |
|------+----------+-------------------------------------------------------|
| TRAS | 1-15 | Number of the TR in which the analysis is to continue |
|------+----------+-------------------------------------------------------|
| RCS | 1-17 | Rank of the digit from which the analysis must |
| | | continue in the previously specified TR. |
| | | This rank is relative to the first digit analysed |
| | | in the initial TR. |
|------+----------+-------------------------------------------------------|
| NDST | desname | destination name (6 characters maximum) |
|------+----------+-------------------------------------------------------|
| MAR | OBS | Observed area code |
|------+----------+-------------------------------------------------------|
| DIS | IID | Area code with IDT possible on per call basis |
| |----------+-------------------------------------------------------|
| | CII | Charge allocation code to be ignored |
| |----------+-------------------------------------------------------|
| | IROC | ROC service prohibited (outgoing exchange only) |
| |----------+-------------------------------------------------------|
| | CARn | Initial discri. (n = 1 to 3). Used in the context of |
| | | Selective Circuit Reservation |
| |----------+-------------------------------------------------------|
| | IDRXA | Received identities screening authorized |
| |----------+-------------------------------------------------------|
| | IDRXI | Received identities screening prohibited |
| |----------+-------------------------------------------------------|
| | IDRXB | Received identities screening blocked |
| |----------+-------------------------------------------------------|
| | IMPO | Imported thousand group routing code |
|------+----------+-------------------------------------------------------|
| DRIn | 0-31 | Service activation on routing code |
| | | |
|-----------------+-------------------------------------------------------|
| NTi i= 1-8 | Type of TR = Carrier / TRI |
| +----------+-------------------------------------------------------|
| | 1 | TRI translator |
| |----------+-------------------------------------------------------|
| | 2 | Carrier translator |
| |----------+-------------------------------------------------------|
| | 3 | reserve |
| |----------+-------------------------------------------------------|
| | = | |
| |----------+-------------------------------------------------------|
| | 8 | reserve |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 43/145 !
+---------------------------------------------------------------------------------+
+---------------------------------------------------------------------------}
| |
| (P) TITLE : Analysis |
| |
|---------------------------------------------------------------------------|
| Cmd parameter | |
|-------------------| MEANING |
| Symbol| Value | |
|-------+-----------+-------------------------------------------------------|
| DIS = | DIn | Standard class markings (COS) |
| | 1-8 | |
| | | |
| |-----------+-------------------------------------------------------|
| | DI1 | |
| |-----------+-------------------------------------------------------|
| | DI2 | Request calling party number |
| |-----------+-------------------------------------------------------|
| | DI3 | Concatenation noDE with noDR |
| |-----------+-------------------------------------------------------|
| | DI4 | Concatenation noDE with first DR |
| |-----------+-------------------------------------------------------|
| | DI5 | |
| |-----------+-------------------------------------------------------|
| | DI6 | |
| |-----------+-------------------------------------------------------|
| | DI7 | Call with holding called |
| |-----------+-------------------------------------------------------|
| | DI8 | |
+---------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 44/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| (A) TITLE : Analysis, assignment of translator numbers |
| |
|-------------------------------------------------------------------------|
|TRAD | Assignment |
|------+------------------------------------------------------------------|
| 1 | |
|------+------------------------------------------------------------------|
| 2 | |
|------+------------------------------------------------------------------|
| 3 | |
|------+------------------------------------------------------------------|
| 4 | |
|------+------------------------------------------------------------------|
| 5 | |
|------+------------------------------------------------------------------|
| 6 | |
|------+------------------------------------------------------------------|
| 7 | |
|------+------------------------------------------------------------------|
| 8 | |
|------+------------------------------------------------------------------|
| 9 | |
|------+------------------------------------------------------------------|
| 10 | |
|------+------------------------------------------------------------------|
| 11 | |
|------+------------------------------------------------------------------|
| 12 | |
|------+------------------------------------------------------------------|
| 13 | |
|------+------------------------------------------------------------------|
| 14 | |
|------+------------------------------------------------------------------|
| 15 | |
|-------------------------------------------------------------------------|
| TRDAi Digits associated with the RA transporter |
| i = +----------------------------------------------------------------|
| 1-4 | TRDA1 | TRDA2 | TRDA3 | TRDA4 |
| |---------------+---------------+---------------+----------------|
| | | | | |
|-------------------------------------------------------------------------|
| TRDBi Digits associated with the RB transporter |
| i = +----------------------------------------------------------------|
| 1-4 | TRDB1 | TRDB2 | TRDB3 | TRDB4 |
| |---------------+---------------+---------------+----------------|
| | | | | |
|-------------------------------------------------------------------------|
| TRDCi Digits associated with the RC transporter |
| i = +----------------------------------------------------------------|
| 1-4 | TRDC1 | TRDC2 | TRDC3 | TRDC4 |
| |---------------+---------------+---------------+----------------|
| | | | | |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 45/145 !
+---------------------------------------------------------------------------------+
2.3 ROUTING MANAGEMENT (x)

2.3.1 GENERAL PARAMETERS (x)

+-------------------------------------------------------------------------+
| |
| (S) TITLE : Routing |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| ACH = | 1-4095 | Routing number |
|---------+--------+------------------------------------------------------|
| TYPE = | = 1 | Routing to circuit group plus sending |
| |--------+------------------------------------------------------|
| | = 2 | Routing to circuit group without sending |
| |--------+------------------------------------------------------|
| | = 3 | Local routing |
| |--------+------------------------------------------------------|
| | = 4 | Routing to recorded announcement |
| |--------+------------------------------------------------------|
| | = 5 | Maintenance routing |
| |--------+------------------------------------------------------|
| | = 6 | Routing with address digit recreation |
| |--------+------------------------------------------------------|
| | = 7 | Geographical area (ZG) dependent routing |
| |--------+------------------------------------------------------|
| | = 8 | Outgoing routing different from incoming |
| |--------+------------------------------------------------------|
| | = 9 | Remote control dependent routing |
| |--------+------------------------------------------------------|
| | =10 | Time dependent routing |
| |--------+------------------------------------------------------|
| | =11 | Shared load routing |
| |--------+------------------------------------------------------|
| | =12 | Call distribution routing |
| |--------+------------------------------------------------------|
| | =13 | CTI dependent routing |
| |--------+------------------------------------------------------|
| | =14 | CSI dependent routing |
| |--------+------------------------------------------------------|
| | =15 | Routing to INER1 server |
| |--------+------------------------------------------------------|
| | =16 | Routing to supplementary service |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 46/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE : Routing |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| TYPE = | =17 | Routing on tone |
| |--------+------------------------------------------------------|
| | =18 | not used |
| |--------+------------------------------------------------------|
| | =19 | not used |
| |--------+------------------------------------------------------|
| | =20 | Routing dependent on a parametered indexation |
| |--------+------------------------------------------------------|
| | =21 | Routing to an external INCS1 service |
+-------------------------------------------------------------------------+

+-------------------------------------------------------------------------+
| |
| (S) TITLE : Routing |
| |
|-------------------------------------------------------------------------|
| Parameter | | |
|------------------| TYPE | MEANING |
| Name | Value | | |
|---------+--------+-------+----------------------------------------------|
| NFSC = | Name |1,2,4,5| Circuit group name |
| | 1-5 | char | |
|---------+--------+-------+----------------------------------------------|
| RCR = | 1-31 |1,2,4,6| Rank of the last digit received before |
| | | | forwarding |
|---------+--------+-------+----------------------------------------------|
| RPCE = | 1-15 | 1 | Rank of the first digit transmitted on the |
| | | | circuit group |
|---------+--------+-------+----------------------------------------------|
| AC = | X-Y | 1 | Access code transmitted on the circuit group |
| | 1 to 15| | AC = digit X - digit Y |
|---------+--------+-------+----------------------------------------------|
| ACD = | 1-4095 |1,2,4 | Alternative routing |
|---------+--------+-------+----------------------------------------------|
| FILM = | 1-30 |1,2,5,6| Dissuasion announcement for outgoing calls |
| | |-------+----------------------------------------------|
| | | 3 | Dissuasion announcement for incoming calls |
| | |-------+----------------------------------------------|
| | | 16 | Dissuasion announcement |
| +--------+-------+----------------------------------------------|
| | 1-120 | 4 | Announcement related routing |
|---------+--------+-------+----------------------------------------------|
| IND = | Digit | 1 | Digit to be added, inserted or substituted in|
| | 1 to 15| | the number received before forwarding |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 47/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE : Routing |
| |
|-------------------------------------------------------------------------|
| Parameter | | |
|------------------| TYPE | MEANING |
| Name | Value | | |
|---------+--------+-------+----------------------------------------------|
| CAR = | NBRSi | 1,2 | Number of reselections authorized on routing |
| | 1 to 15| | |
| |--------+-------+----------------------------------------------|
| | PREi | 6 | Number of the pre-analysis file in which the |
| | 1 to 15| | first pre-analysis of NAR is to be peformed |
| |--------+-------+----------------------------------------------|
| | TRADi | 6 | Number of the analysis file in which the |
| | 1 to 15| | first analysis of NAR is to be performed |
| | | | rule: If PREA=TRAD=0 |
| | | | then PREA=PREABE (FPAM33) |
| |--------+-------+----------------------------------------------|
| | NTONi | 17 | Tone number |
| | 1-255 | | |
| |--------+-------+----------------------------------------------|
| | TYFAx | 16 | Type of chargable facility or supplementary |
| | 1-31 | | service |
| |--------+-------+----------------------------------------------|
| | TYPUx | 16 | Use of the facility |
| | 1-15 | | (enable, check, use, disable) |
| |--------+-------+----------------------------------------------|
| | RPi | 6 | (Used with NAR absent). Indicates the number |
| | 1-15 | | of digits to be taken into account before |
| | | | the 1st digit analysed to restart the |
| | | | analysis (TRADm) or the preanalysis (PREAn) |
| |--------+-------+----------------------------------------------|
| | RSi | 6 | (Used with NAR absent). Indicates the number |
| | 1-15 | | of digits to be ignored after the 1st digit |
| | | | analysed to restart the analysis (TRADm) |
| | | | or the preanalysis (PREAn). |
|---------+--------+-------+----------------------------------------------|
| NAR = | digits | 6 | Number |
| | 1-14 | | See also CAR=PREi and CAR=TRADi |
|---------+--------+-------+----------------------------------------------|
| MAR = | OBS | All | Observation mark |
| |--------+-------+----------------------------------------------|
| | LOC | 7<12 | Local routing |
| |--------+-------+----------------------------------------------|
| | CAL | 10 | Time dependent routing |
| |--------+-------+----------------------------------------------|
| | BLO | 15 | Server routing blocked |
| |--------+-------+----------------------------------------------|
| | AND | 7<12 | Routing associated with an ND |
| | | 16<18 | |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 48/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE : Routing |
| |
|-------------------------------------------------------------------------|
| Parameter | | |
|------------------| TYPE | MEANING |
| Name | Value | | |
|---------+--------+-------+----------------------------------------------|
| ND = | 5 to 11| 1 | Routing to ND with num sent |
| | digits | | ND excludes NFSC, ACD, CAR=NBRSi |
|---------+--------+-------+----------------------------------------------|
| DIS = | A | 1/21 | Addition of the first area code digit |
| | | | - Must be associated with cmd. param. IND= A |
| |--------+-------+----------------------------------------------|
| | AB | 1/21 | Addition of two digits to the area code |
| | | | - Must be associated with cmd. param. IND= AB|
| |--------+-------+----------------------------------------------|
| | PRn | 1/21 | Transmission of n area code digits preceding |
| | 1 to 15| | the first significant digit |
| |--------+-------+----------------------------------------------|
| | AMn | 1/21 | Addition, modification before digit n of the |
| | 1 to 15| | initial number |
| | | | 1<k<15 (k= number of digits in new area code)|
| |--------+-------+----------------------------------------------|
| | IMn | 1/21 | Insertion of a digit after digit n of the |
| | | | initial number |
| | 1 to 15| | - Associated with cmd. par. IND='i1.......ik'|
| | | | 1<k<4 (k: number of digits to be inserted) |
| |--------+-------+----------------------------------------------|
| | CN | 1/21 | Complete address modification |
| | | | IND='i1....ik' (1<k<15, k: number of digits |
| | | | in new number) |
| |--------+-------+----------------------------------------------|
| | I |1,2,5, | Direction barred to outgoing calls |
| | | 16 | |
| |--------+-------+----------------------------------------------|
| | C | 1<6 | Direction allowed to incoming calls |
| | | 16,17 | |
| |--------+-------+----------------------------------------------|
| | IRV |1<6,16 | Call forwarding not allowed |
| | | 17,21 | |
| |--------+-------+----------------------------------------------|
| | IST |1<6,16 | Mandatory calling party charging for calls |
| | | 17,21 | routed in this direction |
| |--------+-------+----------------------------------------------|
| | TR | 1 | Transit operation authorized |
| |--------+-------+----------------------------------------------|
| | URG |1<4,6 | Urgency of call |
| | |16,17 | |
| | |21 | |
| |--------+-------+----------------------------------------------|
| | INF | 4 | Information announcement |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 49/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE : Routing |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| DIS = | DEI | Routing with accounting (TYPACH 1,2,4,6) |
| |--------+------------------------------------------------------|
| | ACS | Routing requiring echo suppressor |
| |--------+------------------------------------------------------|
| | IRX | Routing barred to forwarded calls unless the |
| | | subscriber has category RAIN |
| |--------+------------------------------------------------------|
| | FINU | End of address signal |
| |--------+------------------------------------------------------|
| | CRA | Output Call Details if the incoming circuit group |
| | | has the category CTA=CRA |
| |--------+------------------------------------------------------|
| | IECT | Prohibition of call transfer for all |
| |--------+------------------------------------------------------|
| | IECTX | Prohibition of call transfer for all non ECTI |
| | | discriminated subscribers |
| |--------+------------------------------------------------------|
| | FITX | Filtering of ISUP and SSUTR2 charging messages |
| |--------+------------------------------------------------------|
| | REAi | Call rerouting according to the downstream |
| | | congestion conditions - i = 1 / 2 |
| |--------+------------------------------------------------------|
| | TNS | Autorise la transmission du numéro de transporteur |
| | | en signalisation No7. Utilisé avec TYPACH 1. |
| |--------+------------------------------------------------------|
| | RAi | Range of routing restriction (1-i-15) |
|---------+--------+------------------------------------------------------|
| RPCES | N1 | 1st digit range of calling number SSCS (N1= 1 to 15) |
|---------+--------+------------------------------------------------------|
| ACSS | | SSCS numbering scheme and nature of address |
| | N1-N2 | N1 = 1 to 15 and N2 = 0 to 15 |
|---------+--------+------------------------------------------------------|
| IPROC | 0/1 | Ban of introduction of ROC service |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 50/145 !
+---------------------------------------------------------------------------------+
2.3.2 FILTERING PARAMETERS (x)

+-------------------------------------------------------------------------+
| |
| (S) TITLE : Call gapping |
| (active on type 1 and 2 routings) |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| ACH = | 1-4095 | Routing |
|---------+--------+------------------------------------------------------|
| FIL = | FT | All calls barred |
| | | |
| |--------+------------------------------------------------------|
| | FV | Channel barred, calls forwarded to alternative |
| | | route if existing |
| |--------+------------------------------------------------------|
| | FPn | Gapping, n calls out of 8 are forwarded to |
| |1<n<7 | announcement |
| |--------+------------------------------------------------------|
| | FDn | Alternative route gapping, n calls out of 8 are |
| |1<n<7 | forwarded to calls barred announcement |
| |--------+------------------------------------------------------|
| | NF | Routing without call gapping |
|---------+--------+------------------------------------------------------|
| FILM = |0<x<15 | Number of announcement used with call gapping |
| | | If not specified -> busy or congestion |
| | | |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 51/145 !
+---------------------------------------------------------------------------------+
2.3.3 TYFA-TYPU DESCRIPTION (x)

+--------------------------------------------------------------------------+
| |
| (S) TITLE: Routing Type 16 TYFA-TYPU description |
| |
|--------------------------------------------------------------------------|
| | | | | | |
| Type of facility |MNEMO|TYFA| FUNCTION |TYPU| COMMENTS |
|--------------------+-----+----+---------------+----+---------------------|
| Abbreviated | NAn | 1 | Enter | 1 | PUB+CTX |
| dialling | | |---------------+----| |
| | | | Clear | 2 | |
| | | |---------------+----| |
| | | | Call | 3 | |
| | | |---------------+----| |
| | | | Check or View | 4 | |
| | | | | | Note 1 |
|--------------------+-----+----+---------------+----+---------------------|
| Abbreviated | NLA | 1 | Call | 11 | CTX |
| Dialling | | | | | List of 10 numbers |
| | | | | | (0 - 9) |
|--------------------+-----+----+---------------+----+---------------------|
| Abbreviated | NLB | 2 | Call | 11 | CTX |
| Dialling | | | | | List of 100 numbers |
| | | | | | (00-99) |
|--------------------+-----+----+---------------+----+---------------------|
| Last number redial | AEN | 2 | Enter | 1 | PUB+CTX |
| | | |---------------+----| |
| | | | Clear | 2 | |
|--------------------+-----+----+---------------+----+---------------------|
| Automatic alarm | DRV | 3 | Enter | 1 | PUB |
| call | | |---------------+----| |
| | | | Clear | 2 | |
| | | |---------------+----| |
| | | | Check | 4 | |
| | | |---------------+----| |
| | | | Clear all | 5 | |
|--------------------+-----+----+---------------+----+---------------------|
| Diary call | RDV | 3 | Enter | 9 | PUB/CTX |
| | | |---------------+----| |
| | | | Clear | 10 | |
| | | |---------------+----| |
| | | | Check | 12 | |
+--------------------------------------------------------------------------+

PUB= "PUBLIC" application - CTX= "CENTREX" application


TYFA=3 -> RDV is always offered for Centrex subscribers.
DRV or RDV is offered for public subscribers.

Centrex fonction allowed only on local zone.

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 52/145 !
+---------------------------------------------------------------------------------+
+--------------------------------------------------------------------------+
| |
| (S) TITLE : Routing Type 16 TYFA-TYPU description |
| |
|--------------------------------------------------------------------------|
| | | | | | |
| Type of facility |MNEMO|TYFA| FUNCTION |TYPU| COMMENTS |
|--------------------+-----+----+---------------+----+---------------------|
| Forwarding all | RVT | 4 | Enter | 1 | PUB+CTX |
| calls | | |---------------+----| |
| | | | Clear | 2 | |
| | | |---------------+----| |
| | | | View | 3 | |
| | | |---------------+----| |
| | | | Check | 4 | |
| | | |---------------+----| |
| | | | Disable by C | 6 | |
| | | |---------------+----| |
| | | | Check or view | 7 | Note 1 |
|--------------------+-----+----+---------------+----+---------------------|
| Preset forwarding | FIE | 4 | Enable | 13 | CTX |
| ( Manager/Sec ) | | |---------------+----| |
| | | | Disable | 14 | |
| | | |---------------+----| |
| | | | Priority | 15 | |
| | | | man/sec call | | |
|--------------------+-----+----+---------------+----+---------------------|
| Forwarding on busy | RVO | 5 | Enter | 9 | PUB+CTX |
| | | |---------------+----| Valid in CENTREX if |
| | | | Check | 12 | calls can be |
| | | | | | forwarded outside |
| | | |---------------+----| the company |
| | | | Clear | 10 | => RVX=1 in FIPAM |
| | | |---------------+----| |
| | | | Check or view | 15 | Note 1 |
|--------------------+-----+----+---------------+----+---------------------|
| Malicious call | IAM | 5 | Use | 3 | PUB -> use with |
| identification | | | | | flashing buton |
| | | | | | CTX -> use prefix |
| | | | | | ident./ PREANALYSE |
|--------------------+-----+----+---------------+----+---------------------|
| Forwarding to | AAB | 6 | Enter | 1 | PUB+CTX |
| absent subscriber | | |---------------+----| |
| service | | | Clear | 2 | |
| | | |---------------+----| |
| | | | Check | 4 | |
+--------------------------------------------------------------------------+

Note 1.
When using a TYPU "Check or View" facility, the syntax is as follows:
PP ND ? for the checking function.
PP ? for viewing activation.
where the PP prefix is the one for each facility being checked or viewed.

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 53/145 !
+---------------------------------------------------------------------------------+
+--------------------------------------------------------------------------+
| |
| (S) TITLE : Routing Type 16 TYFA-TYPU description |
| |
|--------------------------------------------------------------------------|
| | | | | | |
| Type of facility |MNEMO|TYFA| FUNCTION |TYPU| COMMENTS |
|--------------------+-----+----+---------------+----+---------------------|
| Call forwarding on | DNR | 6 | Enter | 9 | Valid in CENTREX if |
| no answer | | |---------------+----| calls can be |
| | | | Check | 12 | forwarded outside |
| | | |---------------+----| |
| | | | Clear | 10 | => RVX=1 in FIPAM |
| | | |---------------+----| |
| (1) | | | Modify timer | 11 | PUB+CTX (1) |
| | | | | | (CFNR record) |
| | | |---------------+----| |
| (2) | | | Check or view | 15 | PUB+CTX (2) |
| | | |---------------+----+---------------------|
| | | | Enable | 13 | CTX-Call forwarding |
| | | |---------------+----| outside the company |
| | | | Disable | 14 | not allowed |
| | | | | | => RVX=0 in FIPAM |
|--------------------+-----+----+---------------+----+---------------------|
| Group forwarding | | 7 | Enable | 13 | CTX |
| | | |---------------+----| Call forwarding |
| | | | Disable | 14 | outside the company |
| | | | | | not allowed |
|--------------------+-----+----+---------------+----+---------------------|
| Call waiting | IAI | 8 | Enter | 1 | PUB+CTX |
| | | |---------------+----| |
| | | | Clear | 2 | |
| | | |---------------+----| |
| | | | Check | 4 | |
|--------------------+-----+----+---------------+----+---------------------|
| Call from destin- | | 8 | Use | 11 | CTX - with RVX=0 |
| ation number to | | | | | used FIE+RVO+DNR |
| forwarding number | | | | | with RVX=1, |
| to set up transfer | | | | | FIE only |
|--------------------+-----+----+---------------+----+---------------------|
| Standby | DMV | 9 | Enable | 13 | CTX |
| (1) | | |---------------+----| RVX=0 =>FIE+RVO+DNR |
| | | | Clear | 14 | RVX=1 =>FIE |
|--------------------+-----+----+---------------+----+---------------------|
| Controlled access | SRC | 9 | Enable | 3 | PUB+CTX |
| barring: | | |---------------+----| |
| Variant 1 | | | Disable | 2 | |
| | | |---------------+----| |
| | | | Check | 4 | |
+--------------------------------------------------------------------------+

(1) Same timer TNR as RFNR -TYPU11/TYFA18


(2) On/off by manager/sec or operator

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 54/145 !
+---------------------------------------------------------------------------------+
+--------------------------------------------------------------------------+
| |
| (S) TITLE : Routing Type 16 TYFA-TYPU description |
| |
|--------------------------------------------------------------------------|
| | | | | | |
| Type of facility |MNEMO|TYFA| FUNCTION |TYPU| COMMENTS |
|--------------------+-----+----+---------------+----+---------------------|
| Controlled access | SRC | 9 | Enable | 3 | PUB+CTX |
| barring: | | |---------------+----| |
| variant 2 | | | Disable | 2 | |
| | | |---------------+----| |
| | | | Check | 4 | |
|--------------------+-----+----+---------------+----+---------------------|
| Controlled access | SRC | 9 | Enable | 3 | PUB+CTX |
| barring: | | |---------------+----| |
| variant 3 | | | Disable | 2 | |
| | | |---------------+----| |
| | | | Check | 4 | |
| | | |---------------+----| |
| | | | Modify code | 1 | |
|--------------------+-----+----+---------------+----+---------------------|
| Controlled access | SRC | 9 | Enable 1: | 3 | PUB+CTX |
| barring: | | | CODE-SR | | |
| variant 4 | | |---------------+----+---------------------|
| | | | Enable 2: | 5 | PUB+CTX |
| | | | SR-CODE | | |
| | | |---------------+----+---------------------|
| | | | Enable 3: | 6 | PUB+CTX |
| | | | CODE-SR2 | | SR = 2 digits |
| | | |---------------+----+---------------------|
| | | | Enable 4: | 7 | PUB+CTX |
| | | | SR2-CODE | | SR = 2 digits |
| | | |---------------+----+---------------------|
| | | | Disable | 2 | PUB+CTX |
| | | |---------------+----+---------------------|
| | | | Check | 4 | PUB+CTX |
|--------------------+-----+----+---------------+----+---------------------|
| Controlled access | SRC | 9 | Enable 1: | 3 | PUB+CTX |
| barring: | | | CODE-SR | | |
| variant 5 | | |---------------+----+---------------------|
| | | | Enable 2: | 5 | PUB+CTX |
| | | | SR-CODE | | |
| | | |---------------+----+---------------------|
| | | | Enable 3: | 6 | PUB+CTX |
| | | | CODE-SR2 | | SR = 2 digits |
| | | |---------------+----+---------------------|
| | | | Enable 4: | 7 | PUB+CTX |
| | | | SR2-CODE | | SR = 2 digits |
| | | |---------------+----+---------------------|
| | | | Disable | 2 | PUB+CTX |
| | | |---------------+----+---------------------|
| | | | Check | 4 | PUB+CTX |
| | | |---------------+----+---------------------|
| | | | Modify code | 1 | PUB+CTX |
+--------------------------------------------------------------------------+
+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 55/145 !
+---------------------------------------------------------------------------------+
+--------------------------------------------------------------------------+
| |
| (S) TITLE : Routing Type 16 TYFA-TYPU description |
| |
|--------------------------------------------------------------------------|
| | | | | | |
| Type of facility |MNEMO|TYFA| FUNCTION |TYPU| COMMENTS |
|--------------------+-----+----+---------------+----+---------------------|
| Controlled access | SRC | 9 | Enable 1: | 3 | PUB+CTX |
| barring: | | | CODE-SR | | |
| Variant 6 | | |---------------+----+---------------------|
| | | | Enable 2: | 5 | PUB+CTX |
| | | | SR-CODE | | |
| | | |---------------+----+---------------------|
| | | | Enable 3: | 6 | PUB+CTX |
| | | | CODE-SR2 | | SR = 2 digits |
| | | |---------------+----+---------------------|
| | | | Enable 4: | 7 | PUB+CTX |
| | | | SR2-CODE | | SR = 2 digits |
| | | |---------------+----+---------------------|
| | | | Disable | 2 | PUB+CTX |
| | | |---------------+----+---------------------|
| | | | Check | 4 | PUB+CTX |
|--------------------+-----+----+---------------+----+---------------------|
| Controlled access | SRC | 9 | Enter | 3 | PUB+CTX |
| barring: | | |---------------+----| |
| Variant 7 | | | Modify code | 1 | |
|--------------------+-----+----+---------------+----+---------------------|
| Line with delayed | LAT | 10 | Enter | 1 | PUB+CTX |
| routing | | |---------------+----| |
| (1) | | | Clear | 2 | |
| | | |---------------+----| |
| | | | Check | 4 | |
| | | |---------------+----| |
| | | | Check | 5 | |
| | | | or view | | Note 1 |
|--------------------+-----+----+---------------+----+---------------------|
| Ringing test | | 11 | Use | 1 | PUB+CTX |
|--------------------+-----+----+---------------+----+---------------------|
| Audibility test | | 11 | Use | 2 | PUB+CTX |
|--------------------+-----+----+---------------+----+---------------------|
| Call Pick Up | GIA | 12 | Use | | CTX |
| | | | - without ND | 11 | |
| | | | - with ND | 15 | |
+--------------------------------------------------------------------------+

(1) TYFA/TYPU keyboard syntax registration, declared in preanalysis.

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 56/145 !
+---------------------------------------------------------------------------------+
+--------------------------------------------------------------------------+
| |
| (S) TITLE : Routing Type 16 TYFA-TYPU description |
| |
|--------------------------------------------------------------------------|
| | | | | | |
| Type of facility |MNEMO|TYFA| FUNCTION |TYPU| COMMENTS |
|--------------------+-----+----+---------------+----+---------------------|
| Automatic callback | SRS | 13 | Enter | 1 | PUB |
| to busy number for | | |---------------+----| |
| local numbers | | | Clear | 2 | |
|--------------------+-----+----+---------------+----+---------------------|
| Automatic callback | RAL | 13 | Enter | 9 | CTX |
| to busy number for | | |---------------+----| |
| local numbers | | | Clear | 10 | |
|--------------------+-----+----+---------------+----+---------------------|
| Do Not Disturb | DND | 14 | Enter | 1 | PUB+CTX |
| | | |---------------+----| |
| | | | Clear | 2 | |
| | | |---------------+----| |
| | | | Check | 4 | |
|--------------------+-----+----+---------------+----+---------------------|
| Forward to absent | AAB | 15 | Enter | 1 | PUB+CTX |
| subscriber service | | |---------------+----| |
| (to operator) | | | Clear | 2 | |
| | | |---------------+----| |
| | | | Check | 4 | |
|--------------------+-----+----+---------------+----+---------------------|
| | | | Check | 4 | PUB+CTX |
| | | |---------------+----| |
| Unconditional | RVFT| 16 | Enable | 5 | |
| fixed call | | |---------------+----| |
| forwarding | | | Disable | 6 | |
|--------------------+-----+----+---------------+----+---------------------|
| | | | Check | 4 | PUB+CTX |
| | | |---------------+----| |
| Fixed call | RVFO| 17 | Enable | 5 | |
| forwarding | | |---------------+----| |
| on busy | | | Disable | 6 | |
|--------------------+-----+----+---------------+----+---------------------|
| | | | Check | 4 | PUB+CTX |
| | | |---------------+----| |
| Fixed call | RFNR| 18 | Enable | 5 | |
| forwarding | | |---------------+----| |
| on no answer | | | Disable | 6 | |
| | | |---------------+----| |
| (1) | | | Modify timer | 11 | (CFNR record) |
+--------------------------------------------------------------------------+

(1) Same timer TNR as DNR -TYPU11/TYFA6

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 57/145 !
+---------------------------------------------------------------------------------+
+--------------------------------------------------------------------------+
| |
| (S) TITLE : Routing Type 16 TYFA-TYPU description |
| |
|--------------------------------------------------------------------------|
| | | | | | |
| Type of facility |MNEMO|TYFA| FUNCTION |TYPU| COMMENTS |
|--------------------+-----+----+---------------+----+---------------------|
| Fixed LAT | LATF| 19 | Enable | 5 | PUB+CTX |
| | | | | | |
| | | |---------------+----| |
| | | | Disable | 6 | |
| | | | | | |
|--------------------+-----+----+---------------+----+---------------------|
| Single access code | (X) | 20 | Initialise | 1 | PUB+CTX |
| | | | voice mailbox | | |
| | | | and activate | | |
| | | | list 1 | | |
| | | |---------------+----| |
| | | | Act. list 1 | 2 | |
| | | | directly | | |
| | | |---------------+----| |
| | | | Disable | 3 | |
| | | | list 1 | | |
| | | |---------------+----| |
| | | | Activate | 4 | |
| | | | list 2 | | |
| | | |---------------+----| |
| | | | Disable | 5 | |
| | | | list 2 | | |
|--------------------+-----+----+---------------+----+---------------------|
| Test program | TYQ1| 21 | Use | 3 | |
|--------------------+-----+----+---------------+----+---------------------|
| Anonymous call | ACR | 22 | Enable | 1 | PUB+CTX |
| rejection | | |---------------+----| |
| | | | Disable | 2 | |
| | | |---------------+----| |
| | | | Check | 4 | |
|--------------------+-----+----+---------------+----+---------------------|
| Calling Line | SECR| 23 | Presentation | 1 | PUB+CTX |
| Identification | | | forbidden | | |
| | | |---------------+----| |
| | | | Presentation | 2 | |
| | | | authorised | | |
| | | |---------------+----| |
| | | | View | 3 | |
+--------------------------------------------------------------------------+

(X): Category of each service

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 58/145 !
+---------------------------------------------------------------------------------+
+--------------------------------------------------------------------------+
| |
| (S) TITLE : Routing Type 16 TYFA-TYPU description |
| |
|--------------------------------------------------------------------------|
| | | | | | |
| Type of facility |MNEMO|TYFA| FUNCTION |TYPU| COMMENTS |
|--------------------+-----+----+---------------+----+---------------------|
| Filtering of i/c | DFA | 24 | Recording of | 1 | PUB+CTX |
| calls | | | number on | | |
| | | | black list | | |
| | | |---------------+----| |
| | | | Deletion of | 2 | |
| | | | number on | | |
| | | | black list | | |
| | | |---------------+----| |
| | | | Activation of | 3 | |
| | | | filtering | | |
| | | |---------------+----| |
| | | | Deactivation | 4 | |
| | | | of filtering | | |
|--------------------+-----+----+---------------+----+---------------------|
| Automatic callback | ROC | 25 | Unitary | 6 | PUB+CTX |
| to busy subscriber | | | deactivation | | |
|/ISDN sub=CCBS-T/ST |/CCBS| |---------------+----| |
| | | | Global | 7 | |
| | | | deactivation | | |
|--------------------+-----+----+---------------+----+---------------------|
| Carrier selection | STR | 27 | Modify | 1 | PUB+CTX |
| with subscription | | | Traffic A | | |
| | | |---------------+----| |
| | | | Traffic B | 2 | |
| | | |---------------+----| |
| | | | Traffic C | 3 | |
| | | |---------------+----| |
| | | | All Traffic | 5 | |
|--------------------+-----+----+---------------+----+---------------------|
| ATME | | 28 | Use | 3 | PUB+CTX |
|--------------------+-----+----+---------------+----+---------------------|
| Last calling party | RDA | 29 | Registration | | PUB+CTX |
| recall | | | of NAR | 1 | cf note 1 |
| (Call Return) | | |---------------+----| |
| | | | Clear | 2 | cf note 2 |
| | | |---------------+----| |
| | | | Invoke | 3 | cf note 3 |
| | | |---------------+----| |
| | | | View | 4 | NAR information |
|--------------------+-----+----+---------------+----+---------------------|
| Closed User Group | GFU | 31 | Invoke | 3 | PUB |
| | | | | | Used in pre-analysis|
+--------------------------------------------------------------------------+

-Note 1 : Automatic registration of number (ie. without Called party


intervention), if the called has RDA category, after display
to the called party, and the call:
- stay without answer (of called party), or
+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 59/145 !
+---------------------------------------------------------------------------------+
- without engagement in IAI (by called party).
-Note 2 : Erasing by called (becoming caller who dial proper syntax)
to clear the last calling party number (used in pre-analysis)
-Note 3 : Invocation by the called (becoming caller with proper syntax)
to recall the last calling party (used in pre-analysis)

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 60/145 !
+---------------------------------------------------------------------------------+
2.3.4 ROUTING TYPE PARAMETERS (x)

+-------------------------------------------------------------------------+
| |
| (S) RUBRIC: Routing with recreation of directory number |
| Type 6 |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| NAR = | Ind | Code to be recreated as it would have been dialled |
| | | by the subscriber |
|---------+--------+------------------------------------------------------|
| CAR = | TRADi | i from 1 to 15: Number of the analysis file in which|
| | | the first NAR analysis must be carried out |
| |--------+------------------------------------------------------|
| | PREj | j from 1 to 15: Number of the preanalysis file in |
| | | which the first NAR analysis must be carried out |
+-------------------------------------------------------------------------+

+-------------------------------------------------------------------------+
| |
| (S) RUBRIC: Routing to numbering reanalysis |
| Type 6 |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| NAR | non | This routing is a type 6 routing sub-type |
| | | characterised by the absence of NAR |
| | | In the context of a Local Sort Area and used in a |
| | | sort translator to index the analysis of the |
| | | numbering by ZLT in place of CAC. |
|---------+--------+------------------------------------------------------|
| CAR = | RPi | Number of digits to acknowledge before the first |
| | | digit analysed to: |
| | | - Either restart an analysis in the specified |
| | | translator (TRADm) |
| | | - Or restart an analysis in the specified |
| | | preanalysis table (PREAn) |
| |--------+------------------------------------------------------|
| | RSi | Number of digits to ignore after the first |
| | | digit analysed to: |
| | | -Either restart an analysis in the specified |
| | | translator (TRADm) |
| | | -Or restart a preanalysis in the specified |
| | | preanalysis table (PREAn) |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 61/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE : CIA2 dependent routing (TNX > 0) Type 7 |
| (TNX=0: CIA/CIX indexation mode) |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| ACM = | X-i | Description of the list of pairs |
| | 1-4095 | |
| |1<i<128 | ACM = Xk-ik (2<k<8) |
| | | where: X routing number 1 < X < ACHmax (4095) |
| | | i routing category 1 < i < CIA2max (128) |
+-------------------------------------------------------------------------+

+-------------------------------------------------------------------------+
| |
| (S) TITLE : MXZG dependent routing (ZTX mode) Type 7 |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| ACM = | X-i | Description of the list of pairs |
| | 1-4095 | |
| |1<i<1023| ACM = Xk-ik (2<k<8) |
| | | where: X routing number 1 < X < ACHmax (4095) |
| | | i routing category 1 < i < MXZG (255) |
+-------------------------------------------------------------------------+

+-------------------------------------------------------------------------+
| |
| (S) TITLE : Outgoing routing different from incoming: Type 8 |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| ACM = | X-i | Description of the list of pairs |
| | 1-4095 | |
| | i=1/2 | ACM = X1-i1 + X2-i2 |
| | | where: X routing number 1 < X < ACHmax (4095) |
| | | i = 1 : Outgoing routing |
| | | i = 2 : Incoming routing |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 62/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE : Remote control dependent routing: Type 9 |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| ACM = | X-i | Description of the list of pairs |
| | 1-4095 | |
| | i=1/2 | where: X routing number 1 < X < ACHmax (4095) |
| | | i = 1 Routing to be used when remote control is |
| | | IDLE |
| | | i = 2 Routing to be used when remote control is |
| | | ACTIVE |
|---------+--------+------------------------------------------------------|
| TCM = | 1-8 | Associated remote control number |
|---------+--------+------------------------------------------------------|
| STATE= | R / T | Remote control state R = IDLE |
| | | T = ACTIVE |
+-------------------------------------------------------------------------+

+-------------------------------------------------------------------------+
| |
| (S) TITLE : Time dependent routing: Type 10 |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| ACM = | X-i | Description of the list of pairs |
| | 1-4095 | ACM = X1-i1 + X2-i2 + Xk-i3 |
| | i=1-3 | where: X routing number 1 < X < ACHmax (4095) |
| | | i routing category 1 < i < 3 max (128) |
|---------+--------+------------------------------------------------------|
| RACH = | 1-3 | Active routing number |
|---------+--------+------------------------------------------------------|
| DAY = | 1-366 | Day of the year |
| | | day=d1+d2<d3...... |
|---------+--------+------------------------------------------------------|
| TYJO = | 0-7 | Type of day |
|---------+--------+------------------------------------------------------|
| HR = | HH-MM | End of period (15 periods / day type) |
| | | HR=H1-M1+H2-M2+....+Hk-Mk where 1 < k < 15 |
|---------+--------+------------------------------------------------------|
| ACH = | (acm) | Multiple routing assigned to a type of day |
|---------+--------+------------------------------------------------------|
| TY = | ACi | Number of the routing assigned to a period |
| | i=1-3 | |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 63/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE : Routing with load sharing: Type 11 |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| ACM = | X-i | Description of the list of pairs |
| | 1-4095 | |
| | 1-99 | ACM = X1-i1 + X2-i2 + ..... + Xk-ik |
| | | where: X routing number 1 < X < ACHmax (4095) |
| | | i percentage of the calls associated with the |
| | | routing 2 < k < 8 (8 possible routings) |
| | | i1 + i2 + ..... + ik must be equal to 100 |
|---------+--------+------------------------------------------------------|
| DIS = | NTj | Number of retries for a given call on this routing |
| | 1<j<8 | |
| | | NTj j = 1 : overflow onto routing ACH=Xk if |
| | | existing and overflow onto ACM if |
| | | existing |
| | | j > 1 : overflow onto ACM if existing after |
| | | successive tests of j routings |
| |--------+------------------------------------------------------|
| | RFI | Forward to special announcement |
|---------+--------+------------------------------------------------------|
| ACD = | 1-4095 | Alternative routing |
+-------------------------------------------------------------------------+

+-------------------------------------------------------------------------+
| |
| (S) TITLE : Routing with call distribution: Type 12 |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| ACM = | X-i | Description of the list of pairs |
| | 1-4095 | |
| | 1<i<99 | ACM = X1-i1 + X2-i2 + ..... + Xk-ik |
| | | where: X routing number 1 < X < ACHmax (4095) |
| | | i percentage of the calls associated with the |
| | | routing 2 < k < 8 (8 possible routings) |
| | | i1 + i2 + ..... + ik must be equal to 100 |
|---------+--------+------------------------------------------------------|
| DIS | RFI | Forward to special announcement |
|---------+--------+------------------------------------------------------|
| ACD = | 1-4095 | Alternative routing |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 64/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE : Routing dependent on CTI (TNX = 0) Type 13 |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| ACM = | X-i | Description of the list of pairs |
| | 1-4095 | |
| | 1<i<7 | ACM = X1-i1 + X2-i2 + ........ + Xk-ik |
| | | where: X routing number 1 < X < ACHmax (4095) |
| | | i routing category 1 < i < MXCTI (7) |
+-------------------------------------------------------------------------+

+-------------------------------------------------------------------------+
| |
| (S) TITLE : Routing dependent on CSI Type 14 |
| (TNX=0 only) |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| ACM = | X-i | Description of the list of pairs |
| | 1-4095 | |
| | 1<i<7 | ACM = X1-i1 + X2-i2 + ........ + Xk-ik |
| | | where: X routing number 1 < X < ACHmax (4095) |
| | | i routing category 1 < i < MXCSI (7) |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 65/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE : Routing to an INER1 server Type 15 |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| TYR = |RN,RI | Indicator of the signalling network to which the |
| | Rx | SSP belongs |
| | 4<x<8 | |
|---------+--------+------------------------------------------------------|
| NSS = | x | SCCP sub-system number |
| |1 to 255| |
|---------+--------+------------------------------------------------------|
| IDSV = | x | Service identifier |
| | 0 to | |
| | 65535 | |
|---------+--------+------------------------------------------------------|
| ASS = | x | SCCP routing number |
| | 1 to 31| |
|---------+--------+------------------------------------------------------|
| PS = | x | Signalling point number |
| | 1 to | |
| | 16383 | |
|---------+--------+------------------------------------------------------|
| PSE = | x | Extended signalling point number |
| | 1 to | |
| |16777215| |
|---------+--------+------------------------------------------------------|
| IDDR = | YES | Calling Subscriber ID presentation |
| | NO | |
| | PREF | |
|---------+--------+------------------------------------------------------|
| AGDE= | a-b-c | First part of called party global address |
| |0<a<255 | a : type of translation |
| |0<b<15 | b : numbering scheme |
| |0<c<127 | c : type of address |
|---------+--------+------------------------------------------------------|
| AGDR= | a-b-c | First part of calling party global address |
| |0<a<255 | a : type of translation |
| |0<b<15 | b : numbering scheme |
| |0<c<127 | c : type of address |
|---------+--------+------------------------------------------------------|
| VPRG = | OiTj | Protocol versions relating to the server |
| |1<i<9 | Oi : operation protocol version |
| |1<j<9 | Tj : TCAP protocol version |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 66/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE : Routing dependent on a parametered indexation |
| (TNX=0 only) Type 20 |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| ACM = | X-i | Description of the list of pairs |
| | 1-4095 | ACM = X1-i1 + X2-i2 + ........ + Xk-ik |
| |1<i<Max | where: X routing number 1 < X < ACHmax (4095) |
| | | i routing category 1 < i < Max function of STY|
|---------+--------+------------------------------------------------------|
| STY = | | Routing sub-type |
| |--------+------------------------------------------------------|
| | SAT | Avoid double satellite hops Max=2 |
| |--------+------------------------------------------------------|
| | TKO | Offer |
| |--------+------------------------------------------------------|
| | STn | Standard parameters (see table type P) |
| |--------+------------------------------------------------------|
| | AXF | Route index linking on type of auxiliary |
| |--------+------------------------------------------------------|
| | CLI | Routing dependent on Calling Line Identity |
| |--------+------------------------------------------------------|
| | CATDR | Routing dependent of calling party category |
| | | (for the values of CATDR see the following table) |
|---------+--------+------------------------------------------------------|
| ACHAUX | 1-4095 | Specially routing by auxiliary circuit group |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 67/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE: Values for CATDR |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|--------------------| MEANING |
| Symbol | Value | |
|-----------+--------+----------------------------------------------------|
| CATDR= | 0 | Unknown |
|0<CATDR<255| 01 | Operator, french language |
| | 02 | Operator, english language |
| | 03 | Operator, german language |
| | 04 | Operator, russian language |
| | 05 | Operator, spanish language |
| | 09 | National operator |
| | 10 | Ordinary subscriber |
| | 11 | Priority subscriber |
| | 12 | Call of datas |
| | 13 | Test call |
| | 15 | Public payphone |
| | 16<224 | Not used |
| | 225 | Subscriber with charging indication |
| | 226 | Subscriber with immediate charging indication |
| | 227 | Operator of interception |
| |228<255 | Not used |
+-------------------------------------------------------------------------+

+-------------------------------------------------------------------------+
| |
| (S) TITLE : Routing to an IN-CS1 server Type 21 |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| IDS= | | Service number |
| |1 to 255| Internal reference used to access the description |
| | | data and the IN-CS1 service access |
|---------+--------+------------------------------------------------------|
| DIS | RAi | Range of routing restriction (1-i-15) |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 68/145 !
+---------------------------------------------------------------------------------+
+-----------------------------------------------------------------}
| |
| (P) TITLE : Routing |
| |
|-----------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+----------------------------------------------|
| STY = | | General sub-group associated with the type |
| | | 20 routing |
| |--------+----------------------------------------------|
| | ST1 | Local assistance |
| |--------+----------------------------------------------|
| | ST2 | Fonction boucle pour INER1 |
| |--------+----------------------------------------------|
| | ST3 | Fonction boucle pour INCS1 |
| |--------+----------------------------------------------|
| | ST4 | Fonction internationale |
| |--------+----------------------------------------------|
| | ST5 | |
| |--------+----------------------------------------------|
| | ST6 | |
| |--------+----------------------------------------------|
| | ST7 | Fonction CAI |
| |--------+----------------------------------------------|
| | ST8 | |
| |--------+----------------------------------------------|
| | ST9 | |
| |--------+----------------------------------------------|
| | ST10 | |
+-----------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 69/145 !
+---------------------------------------------------------------------------------+
+-----------------------------------------------------------------}
| |
| (P) TITLE : Routing |
| |
|-----------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+----------------------------------------------|
| DIS = | DR1 | Request of IDR anticpated |
| |--------+----------------------------------------------|
| | DR2 | Routing No7 with overlapping |
| |--------+----------------------------------------------|
| | DR3 | No sending anticipate IDR |
| |--------+----------------------------------------------|
| | DR4 | Changing taxation mode |
| |--------+----------------------------------------------|
| | DR5 | Changing taxation mode on overflow routing |
| |--------+----------------------------------------------|
| | DRAi | |
| | i from | |
| | 1 to 15| |
| |--------+----------------------------------------------|
| | DRA01 | Send routing tone if ACHT = 0 |
| | +-----+----------------------------------------------|
| | | 02 | |
| | |-----+----------------------------------------------|
| | | 03 | |
| | |-----+----------------------------------------------|
| | | 04 | |
| | |-----+----------------------------------------------|
| | | 05 | |
| | |-----+----------------------------------------------|
| | | 06 | |
| | |-----+----------------------------------------------|
| | | 07 | |
| | |-----+----------------------------------------------|
| | | 08 | Authorized routing at digital connectivity |
| | |-----+----------------------------------------------|
| | | 09 | |
| | |-----+----------------------------------------------|
| | | 10 | |
| | |-----+----------------------------------------------|
| | | 11 | |
| | |-----+----------------------------------------------|
| | | 12 | |
| | |-----+----------------------------------------------|
| | | 13 | |
| | |-----+----------------------------------------------|
| | | 14 | |
| | |-----+----------------------------------------------|
| | | 15 | |
+-----------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 70/145 !
+---------------------------------------------------------------------------------+
+-----------------------------------------------------------------}
| |
| (P) TITLE : Routing |
| |
|-----------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+----------------------------------------------|
| DIS = | DRBi | |
| | i from | |
| | 1 to 15| |
| |--------+----------------------------------------------|
| | DRB01 | |
| | +-----+----------------------------------------------|
| | | 02 | |
| | |-----+----------------------------------------------|
| | | 03 | |
| | |-----+----------------------------------------------|
| | | 04 | |
| | |-----+----------------------------------------------|
| | | 05 | |
| | |-----+----------------------------------------------|
| | | 06 | |
| | |-----+----------------------------------------------|
| | | 07 | |
| | |-----+----------------------------------------------|
| | | 08 | |
| | |-----+----------------------------------------------|
| | | 09 | |
| | |-----+----------------------------------------------|
| | | 10 | |
| | |-----+----------------------------------------------|
| | | 11 | |
| | |-----+----------------------------------------------|
| | | 12 | |
| | |-----+----------------------------------------------|
| | | 13 | |
| | |-----+----------------------------------------------|
| | | 14 | |
| | |-----+----------------------------------------------|
| | | 15 | |
+-----------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 71/145 !
+---------------------------------------------------------------------------------+
+-----------------------------------------------------------------}
| |
| (P) TITLE : Routing |
| |
|-----------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+----------------------------------------------|
| DIS = | DRCi | |
| | i from | |
| | 1 to 15| |
| |--------+----------------------------------------------|
| | DRC01 | |
| | +-----+----------------------------------------------|
| | | 02 | |
| | |-----+----------------------------------------------|
| | | 03 | |
| | |-----+----------------------------------------------|
| | | 04 | |
| | |-----+----------------------------------------------|
| | | 05 | |
| | |-----+----------------------------------------------|
| | | 06 | |
| | |-----+----------------------------------------------|
| | | 07 | |
| | |-----+----------------------------------------------|
| | | 08 | |
| | |-----+----------------------------------------------|
| | | 09 | |
| | |-----+----------------------------------------------|
| | | 10 | |
| | |-----+----------------------------------------------|
| | | 11 | |
| | |-----+----------------------------------------------|
| | | 12 | |
| | |-----+----------------------------------------------|
| | | 13 | |
| | |-----+----------------------------------------------|
| | | 14 | |
| | |-----+----------------------------------------------|
| | | 15 | |
+-----------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 72/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (A) TITLE : Routing |
| |
|-------------------------------------------------------------------------|
| Parameter | | |
|------------------| TYPE | MEANING |
| Symbol | Value | | |
|---------+--------+-------+----------------------------------------------|
| DIS = | SRi | 1<6 |Direction barred to calls from sources |
| | i | 16,17 | with the corresponding calling party |
| | 1 - 15 | | category |
| |--------+-------+----------------------------------------------|
| | SR0 | = | |
| |--------+-------+----------------------------------------------|
| | SR1 | = | |
| |--------+-------+----------------------------------------------|
| | SR2 | = | |
| |--------+-------+----------------------------------------------|
| | SR3 | = | |
| |--------+-------+----------------------------------------------|
| | SR4 | = | |
| |--------+-------+----------------------------------------------|
| | SR5 | = | |
| |--------+-------+----------------------------------------------|
| | SR6 | = | |
| |--------+-------+----------------------------------------------|
| | SR7 | = | |
| |--------+-------+----------------------------------------------|
| | SR8 | = | |
| |--------+-------+----------------------------------------------|
| | SR9 | = | |
| |--------+-------+----------------------------------------------|
| | SR10 | = | |
| |--------+-------+----------------------------------------------|
| | SR11 | = | |
| |--------+-------+----------------------------------------------|
| | SR12 | = | |
| |--------+-------+----------------------------------------------|
| | SR13 | = | |
| |--------+-------+----------------------------------------------|
| | SR14 | = | |
| |--------+-------+----------------------------------------------|
| | SR15 | = | Reserved |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 73/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (A) TITLE : Routing |
| |
|-------------------------------------------------------------------------|
| Parameter | | |
|------------------| TYPE | MEANING |
| Symbol | Value | | |
|---------+--------+-------+----------------------------------------------|
| MAIN = | 1 to 15| | Maintenance device number = |
| | | | FIMAT record number |
| |--------+-------+----------------------------------------------|
| | = 1 | 5 | Trunk hypsometer |
| |--------+-------+----------------------------------------------|
| | = 2 | 5 | R.S.A. circuit tests (the type of test |
| | | | depends on the profile of the circuit group |
| | | | used). |
| |--------+-------+----------------------------------------------|
| | = 3 | 5 | Local hypsometer |
| |--------+-------+----------------------------------------------|
| | = 4 | 5 | DERAL |
| |--------+-------+----------------------------------------------|
| | = 5 | 5 | Simplified R2 tests ( CCITT Q.490 ) |
| |--------+-------+----------------------------------------------|
| | = 6 | | |
| |--------+-------+----------------------------------------------|
| | = 7 | | |
| |--------+-------+----------------------------------------------|
| | = 8 | | |
| |--------+-------+----------------------------------------------|
| | = 9 | | |
| |--------+-------+----------------------------------------------|
| | =10 | | |
| |--------+-------+----------------------------------------------|
| | =11 | | |
| |--------+-------+----------------------------------------------|
| | =12 | | |
| |--------+-------+----------------------------------------------|
| | =13 | | |
| |--------+-------+----------------------------------------------|
| | =14 | | |
| |--------+-------+----------------------------------------------|
| | =15 | | |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 74/145 !
+---------------------------------------------------------------------------------+
2.4 NETWORK PARAMETERS (x)

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 75/145 !
+---------------------------------------------------------------------------------+
3 CIRCUIT GROUP MANAGEMENT (x)

3.1 GENERAL PARAMETERS (x)

+-------------------------------------------------------------------------+
| |
| (S) TITLE: Circuit group management |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| NFSC = | nmfsc | Circuit group name (1 to 5 characters) |
|---------+--------+------------------------------------------------------|
| GENR = | S | Outgoing circuit group |
| | E | Incoming circuit group |
| | M | Bothway circuit group |
| | TD | Circuit group for data transmission with signalling |
|---------+--------+------------------------------------------------------|
| AFCT = | | Number of circuit equipment on IRM: |
| | UR - | 1 < UR < 255 |
| | PCM - | 0 < PCM < on switch hardware configuration |
| | TS | 1 < TS < 31 |
|---------+--------+------------------------------------------------------|
| INDR = |digits | Indicator to put at the start of the number |
| |1<ch<8 | received before translation |
|---------+--------+------------------------------------------------------|
| INDS = |digits | Additional indicator |
| | 1-10 | |
|---------+--------+------------------------------------------------------|
| INDT = |digits | Additional address associated with the circuit group |
| |1<ch<10 | |
|---------+--------+------------------------------------------------------|
| INDE = |digits | Address to be sent when testing the circuits in this |
| | 2<ch<8 | group |
|---------+--------+------------------------------------------------------|
| ACE = | 1<x<15 | Access code to be sent before the test number |
|---------+--------+------------------------------------------------------|
| AEAC = |YES/NO | Automatic authorisation of tests on the circuits in |
| | | the group |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 76/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE : Circuit group management |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| LAW = | 0<n<3 | Law for finding free circuits in a channel-associated|
| | | circuit group |
| |--------+------------------------------------------------------|
| | n= 0 | Cyclic research on circuit sub-groups, random test |
| | | of first circuit in the sub-group, then cyclic test |
| | | on the following circuits |
| |--------+------------------------------------------------------|
| | n= 1 | Cyclic research starting from first sub-group, |
| | | random test of a first circuit in the sub-group |
| | | then cyclic tests on the following circuits. |
| |--------+------------------------------------------------------|
| | n= 2 | |
| |--------+------------------------------------------------------|
| | n= 3 | |
|---------+--------+------------------------------------------------------|
| GABC = | mnemo. | Test category of the circuits in the group |
| |--------+------------------------------------------------------|
| | In | 4-wire trunk (n from 1 to 15) |
| |--------+------------------------------------------------------|
| | Un | 2-wire local (n from 1 to 15) |
| |--------+------------------------------------------------------|
| | Sn | Rapid test (n from 1 to 15) |
| |--------+------------------------------------------------------|
| | Rn | R2 simplified test (CCITT Q490) (n= 1/2) |
| |--------+------------------------------------------------------|
| | Pn | 4-wire India (n from 1 to 15) |
| |--------+------------------------------------------------------|
| | Nn | 2-wire India (n from 1 to 15) |
| |--------+------------------------------------------------------|
| | AAn | Type A R.S.A. test (n from 1 to 15) |
| |--------+------------------------------------------------------|
| | Bn | Type B R.S.A. test (n from 1 to 15) |
| |--------+------------------------------------------------------|
| | Cn | Type C R.S.A. test (n from 1 to 15) |
| |--------+------------------------------------------------------|
| | Dn | Type D R.S.A. test (n from 1 to 15) |
| |--------+------------------------------------------------------|
| | Fn | Type F R.S.A. test (n from 1 to 15) |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 77/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE : Circuit group management |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| MAR = | OBS | Mark for observation of a circuit in the group |
| |--------+------------------------------------------------------|
| | ODT | Mark for traffic dispersion observation |
| |--------+------------------------------------------------------|
| | OFA | Observation on an incoming circuit or group |
| |--------+------------------------------------------------------|
| | OFD | Observation on an outgoing circuit or group |
| |--------+------------------------------------------------------|
| | COB | Circuit observed |
| |--------+------------------------------------------------------|
| | FDS | Circuit group observed (OFDLA) |
| |--------+------------------------------------------------------|
| | STX | Circuit being monitored for charging |
| |--------+------------------------------------------------------|
| | OCA | Observed incoming circuit |
| |--------+------------------------------------------------------|
| | OCD | Observed outgoing circuit |
|---------+--------+------------------------------------------------------|
| BSC | 1 - 96 | BSC number |
|---------+--------+------------------------------------------------------|
| TRAU | 1 to 64| Type of TRAU (Transcoder and Rate Adaptor Unit) |
| | | to BSC (adaptation between coding-bit rate radio |
| | | side and the +64 Kb/s+ PCM side) |
| | | 0 = not used (no TRAU type associated with the |
| | | number relation to the BSC concerned) |
|---------+--------+------------------------------------------------------|
| PCD = |1 to 100| Percentage of circuits to be made one-way |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 78/145 !
+---------------------------------------------------------------------------------+
3.2 NO 7 PARAMETERS (x)

+-------------------------------------------------------------------------+
| |
| (S) TITLE : Circuit group management |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| PS = | n | Signalling point number 1 to 16383 |
|---------+--------+------------------------------------------------------|
| PSE = | n | Extended signalling point number 1 to 16777215 |
| | | (24bits) |
|---------+--------+------------------------------------------------------|
| CIC = |1 - 4095| Circuit identification code |
|---------+--------+------------------------------------------------------|
| CSC = | 0 to 3 | Automatic continuity check |
| |--------+------------------------------------------------------|
| | n= 0 | 2-wire circuits and no continuity check, per call |
| | | basis |
| |--------+------------------------------------------------------|
| | n= 1 | 4-wire circuits and no continuity check, per call |
| | | basis |
| |--------+------------------------------------------------------|
| | n= 2 | 2-wire circuits and continuity check, per call |
| | | basis |
| |--------+------------------------------------------------------|
| | n= 3 | 4-wire circuits and continuity check, per call |
| | | basis |
|---------+--------+------------------------------------------------------|
| TYR = | RN | Type of network = national network (default value) |
| |--------+------------------------------------------------------|
| | RI | Type of network = international network |
| |--------+------------------------------------------------------|
| | Rj | Type of network = network j (j is from 4 to 8) |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 79/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| Selective Circuit Reservation Management |
| |
|-------------------------------------------------------------------------|
| CLR = | 0 - 31 | Reduction class allocated to a circuit group |
|---------+--------+------------------------------------------------------|
| CLRSC= | a-b | Reduction classes associated with the circuit group |
| | | for reduction levels 1 and 2 in the RSC context. |
|---------+--------+------------------------------------------------------|
| MODC = | ma-mb | Operating modes allocated to classes a and b. |
|---------+--------+------------------------------------------------------|
| SRE = | sre1 - | Reservation triggering thresholds |
| | sre2 | (sre2 must be less than or equal to sre1) |
|-------------------------------------------------------------------------|
| |
| Echo device |
| |
|-------------------------------------------------------------------------|
| AUX | 1 - 31 | Auxiliairy type |
| | | |
| | 1 - 16 | IWF (LiEj = L3E13 en _AA) |
| | 17 | AE carte ICAE (LiEj = L3E13 en _AA) |
| | 18 | AE carte ICAEQ (LiEj = L4E13 en _AA) |
| | 19, 20 | autre AE (LiEj = L3E13 en _AA) |
| | 21 -24 | EI (LiEj = L3E13 en _AA) |
| | 25 -31 | available |
|---------+--------+------------------------------------------------------|
| AFCR |-UR | Add function on back circuit |
| | -MIC | |
| | -VT | |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 80/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE: Circuit group management |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| LAW = | 0 - 3 | Law for finding a free circuit in a group |
| | | |
| | | LOI= 0 corresponds to the type A METHOD 1 of CCITT N7|
| | | LOI= 1 corresponds to the type B METHOD 1 of CCITT N7|
| | | LOI= 3 corresponds to METHOD 2 of CCITT N7 |
| | | |
| |--------+------------------------------------------------------|
| | 0 | OPC>DPC : systematic search in from lowest to |
| | | highest CIC number |
| | | DPC>OPC : systematic search from highest to lowest |
| | | CIC number |
| | | In cases of simultaneous seizure, the highest PC |
| | | remains controlling exchange for even CIC numbers |
| | | |
| |--------+------------------------------------------------------|
| | 1 | OPC>DPC : systematic search from highest to lowest |
| | | CIC number |
| | | DPC>OPC : systematic search from lowest to highest |
| | | CIC number |
| | | In cases of simultaneous seizures, the same rules |
| |--------+------------------------------------------------------|
| | 2 | not used |
| | | |
| |--------+------------------------------------------------------|
| | 3 | OPC>DPC : Remains the controller for even CIC no.s |
| | | DPC>OPC : Remains the controller for odd CIC no.s |
| | | |
+-------------------------------------------------------------------------+

NOTE(S): In order to minimise the frequency of simultaneous seizures, the


CCITT recommend is to split the two-way circuit group into two cir-
cuit sub-groups to command calls:
- one sub-group for all the odd CICs for which priority is given in
the centre with the highest SP no.
- one sub-group for all the odd CICs for which the priority is
given in the centre with the lowest SP No.

So:
-Each terminal centre has priority access to the circuit sub-group
for which it plays the managing centre role; it therefore chooses
the OLDEST AVAILABLE (1st released) circuit.
-Each terminal centre also has access to the circuit sub-group for
which it does not play the managing centre role; it therefore
chooses the MOST RECENTLY AVAILABLE (last released) circuit.

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 81/145 !
+---------------------------------------------------------------------------------+
3.3 SIGNALISATIONS (x)

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 82/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------}
| |
| (P) TITLE : Circuit group management |
| |
|-------------------------------------------------------------------------|
| Parameter |CIRCUIT| |
|------------------| GROUP | MEANING |
| Symbol | Value | TYPE | |
|---------+--------+-------+----------------------------------------------|
| SG = | Li Ej | E/S/M | L : Line code (1 to 15) |
| | | | E : Register code (1 to 15) |
| | | | Trunk type: E = Incoming |
| | | | S = Outgoing M = Bothway |
| |--------+-------+----------------------------------------------|
| | L1 E1 | E/S/M | CSE Reveil Subscriber |
| | | | ncode 0 vsg 0 |
| |--------+-------+----------------------------------------------|
| | L2 E1 | E/S/M | PCM Subscriber |
| | | | ncode 33 vsg 0 |
| |--------+-------+----------------------------------------------|
| | L3 E1 | E/S/M | Analog Subscriber |
| | | | ncode 0 vsg 0 |
| |--------+-------+----------------------------------------------|
| | L4 E1 | E/S/M | Digital Subscriber |
| | | | ncode 0 vsg 0 |
| |--------+-------+----------------------------------------------|
| | L1 E2 | E/S/. | E et M / R2 Inde |
| | | | ncode 58 vsg 1 |
| |--------+-------+----------------------------------------------|
| | L1 E2 | E/S/. | E et M / R2 Inde |
| | | | ncode 58 vsg 2 |
| |--------+-------+----------------------------------------------|
| | L1 E2 | E/S/. | E et M / R2 Inde |
| | | | ncode 58 vsg 3 |
| |--------+-------+----------------------------------------------|
| | L1 E2 | E/S/. | E et M / R2 Inde |
| | | | ncode 58 vsg 4 |
| |--------+-------+----------------------------------------------|
| | L2 E2 | E/S/. | DC loop / R2 Inde Digital type 2/ R2 Inde |
| | | | ncode 6 vsg 1 |
| |--------+-------+----------------------------------------------|
| | L2 E2 | E/S/. | DC loop / R2 Inde Digital type 2/ R2 Inde |
| | | | ncode 6 vsg 2 |
| |--------+-------+----------------------------------------------|
| | L2 E2 | E/S/. | DC loop / R2 Inde Digital type 2/ R2 Inde |
| | | | ncode 6 vsg 3 |
| |--------+-------+----------------------------------------------|
| | L2 E2 | E/S/. | DC loop / R2 Inde Digital type 2/ R2 Inde |
| | | | ncode 6 vsg 4 |
| |--------+-------+----------------------------------------------|
| | L6 E2 | E/S/. | Digital type 3/ R2 Inde (Indian PCM) |
| | | | ncode 57 vsg 1 |
| |--------+-------+----------------------------------------------|
| | L6 E2 | E/S/. | Digital type 3/ R2 Inde (Indian PCM) |
| | | | ncode 57 vsg 2 |
+-------------------------------------------------------------------------+
+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 83/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------}
| |
| (P) TITLE : Circuit group management |
| |
|-------------------------------------------------------------------------|
| Parameter |CIRCUIT| |
|------------------| GROUP | MEANING |
| Symbol | Value | TYPE | |
|---------+--------+-------+----------------------------------------------|
| SG = | Li Ej | E/S/M | L : Line code (1 to 15) |
| | | | E : Register code (1 to 15) |
| | | | Trunk type: E = Incoming |
| | | | S = Outgoing M = Bothway |
| |--------+-------+----------------------------------------------|
| | L6 E2 | E/S/. | Digital type 3/ R2 Inde (Indian PCM) |
| | | | ncode 57 vsg 3 |
| |--------+-------+----------------------------------------------|
| | L6 E2 | E/S/. | Digital type 3/ R2 Inde (Indian PCM) |
| | | | ncode 57 vsg 4 |
| |--------+-------+----------------------------------------------|
| | L7 E2 | E/S/. | Digital type 1/ R2 Inde (numerique Inde 3RT) |
| | | | ncode 7 vsg 1 |
| |--------+-------+----------------------------------------------|
| | L7 E2 | E/S/. | Digital type 1/ R2 Inde (numerique Inde 3RT) |
| | | | ncode 7 vsg 2 |
| |--------+-------+----------------------------------------------|
| | L7 E2 | E/S/. | Digital type 1/ R2 Inde (numerique Inde 3RT) |
| | | | ncode 7 vsg 3 |
| |--------+-------+----------------------------------------------|
| | L7 E2 | E/S/. | Digital type 1/ R2 Inde (numerique Inde 3RT) |
| | | | ncode 7 vsg 4 |
| |--------+-------+----------------------------------------------|
| | L12 E2 | E/S/M | Q421 mixte/R2 INT CCITT |
| | | | ncode 47 vsg 5 |
| |--------+-------+----------------------------------------------|
| | L1 E3 | E/S/. | E et M / Decadic |
| | | | ncode 58 vsg 0 |
| |--------+-------+----------------------------------------------|
| | L2 E3 | E/S/. | DC loop / Decadic Digital type 2/ Decadic |
| | | | ncode 6 vsg 0 |
| |--------+-------+----------------------------------------------|
| | L3 E3 | E/S/. | DC loop 3 fils/ Decadic |
| | | | ncode 6 vsg 0 |
| |--------+-------+----------------------------------------------|
| | L4 E3 | E/S/. | Manual board (Trunk Offering)Digital type 2 |
| | | | ncode 6 vsg 0 |
| |--------+-------+----------------------------------------------|
| | L5 E3 | E/S/. | Manual board (Manual Hold ) Digital type 2 |
| | | | ncode 6 vsg 0 |
| |--------+-------+----------------------------------------------|
| | L6 E3 | E/S/. | Digital type 3/Decadic (Indian PCM) |
| | | | ncode 57 vsg 0 |
| |--------+-------+----------------------------------------------|
| | L7 E3 | E/S/. | Digital type 1/ Decadic (numerique Inde 3RT) |
| | | | ncode 7 vsg 2 |
+-------------------------------------------------------------------------+
+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 84/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------}
| |
| (P) TITLE : Circuit group management |
| |
|-------------------------------------------------------------------------|
| Parameter |CIRCUIT| |
|------------------| GROUP | MEANING |
| Symbol | Value | TYPE | |
|---------+--------+-------+----------------------------------------------|
| SG = | Li Ej | E/S/M | L : Line code (1 to 15) |
| | | | E : Register code (1 to 15) |
| | | | Trunk type: E = Incoming |
| | | | S = Outgoing M = Bothway |
| |--------+-------+----------------------------------------------|
| | L12 E3 | E/S/M | Q421 mixte/Decadic clav |
| | | | ncode 47 vsg 1 |
| |--------+-------+----------------------------------------------|
| | L9 E7 | E/S/M | ISUP INTERNATIONAL |
| | | | ncode 70 vsg 0 |
| |--------+-------+----------------------------------------------|
| | L10 E7 | E/S/M | ISUP V2 Inde |
| | | | ncode 70 vsg 0 |
| |--------+-------+----------------------------------------------|
| | L1 E12| ./S/. | IN-ER1 |
| | | | ncode 0 vsg 0 |
| |--------+-------+----------------------------------------------|
| | L1 E12| ./S/. | For internal use routing to MPNA |
| | | | ncode 0 vsg 1 |
| |--------+-------+----------------------------------------------|
| | L1 E12| ./S/. | For internal use routing to IP or DAM |
| | | | ncode 0 vsg 2 |
| |--------+-------+----------------------------------------------|
| | L2 E12| ./S/. | IN-CS1 |
| | | | ncode 0 vsg 0 |
| |--------+-------+----------------------------------------------|
| | L1 E13| ./S/. | BSC |
| | | | ncode 0 vsg 0 |
| |--------+-------+----------------------------------------------|
| | L10 E13| E/S/M | ISUP V2 Inde Boucle |
| | | | ncode 0 vsg 0 |
| |--------+-------+----------------------------------------------|
| | L1 E20| ./S/. | Digital recorder with time signal |
| | | | ncode 64 vsg 0 |
| |--------+-------+----------------------------------------------|
| | L2 E20| ./S/. | Digital recorder without time signal |
| | | | ncode 64 vsg 0 |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 85/145 !
+---------------------------------------------------------------------------------+
3.4 CIRCUIT GROUP CATEGORIES (x)

3.4.1 VARIANT OF SIGNALISATION (VSG) (x)

+---------------------------------------------------------------------------}
| (P) TITLE : Outgoing circuit group management |
|---------------------------------------------------------------------------|
| Parameter |CIRCUIT| |
|------------------| GROUP | MEANING |
| Symbol | Value | TYPE | |
|---------+--------+-------+------------------------------------------------|
| CTA = | VSGn | E/S/M | Signalling variant |
| | | | (n is from 1 to 15) |
| |n =+----+-------+------------------------------------------------|
| | | 0 | E/S/M | CSE Reveil Subscriber |
| | | | | L1 E1 NCODE 0 |
| | | |-------+------------------------------------------------|
| | | | E/S/M | PCM Subscriber |
| | | | | L2 E1 NCODE 33 |
| | | |-------+------------------------------------------------|
| | | | E/S/M | Analog Subscriber |
| | | | | L3 E1 NCODE 0 |
| | | |-------+------------------------------------------------|
| | | | E/S/M | Digital Subscriber |
| | | | | L4 E1 NCODE 0 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | E et M / Decadic |
| | | | | L1 E3 NCODE 58 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | DC loop / Decadic Digital type 2/ Decadic |
| | | | | L2 E3 NCODE 6 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | DC loop 3 fils/ Decadic |
| | | | | L3 E3 NCODE 6 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | Manual board (Trunk Offering)Digital type 2 |
| | | | | L4 E3 NCODE 6 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | Manual board (Manual Hold ) Digital type 2 |
| | | | | L5 E3 NCODE 6 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | Digital type 3/Decadic (Indian PCM) |
| | | | | L6 E3 NCODE 57 |
| | | |-------+------------------------------------------------|
| | | | E/S/M | ISUP INTERNATIONAL |
| | | | | L9 E7 NCODE 70 |
| | | |-------+------------------------------------------------|
| | | | E/S/M | ISUP V2 Inde |
| | | | | L10 E7 NCODE 70 |
| | | |-------+------------------------------------------------|
| | | | E/S/M | IN-ER1 |
| | | | | L1 E12 NCODE 0 |
+---------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 86/145 !
+---------------------------------------------------------------------------------+
+---------------------------------------------------------------------------}
| (P) TITLE : Outgoing circuit group management |
|---------------------------------------------------------------------------|
| Parameter |CIRCUIT| |
|------------------| GROUP | MEANING |
| Symbol | Value | TYPE | |
|---------+--------+-------+------------------------------------------------|
| CTA = | VSGn | E/S/M | Signalling variant |
| | | | (n is from 1 to 15) |
| |n =+----+-------+------------------------------------------------|
| | | 0 | E/S/M | IN-CS1 |
| | | | | L2 E12 NCODE 0 |
| | | |-------+------------------------------------------------|
| | | | ./S/. | BSC |
| | | | | L1 E13 NCODE 0 |
| | | |-------+------------------------------------------------|
| | | | E/S/M | ISUP V2 Inde Boucle |
| | | | | L10 E13 NCODE 0 |
| | | |-------+------------------------------------------------|
| | | | ./S/. | Digital recorder with time signal |
| | | | | L1 E20 NCODE 64 |
| | | |-------+------------------------------------------------|
| | | | ./S/. | Digital recorder without time signal |
| | | | | L2 E20 NCODE 64 |
| | |----+-------+------------------------------------------------|
| | | 1 | E/S/. | E et M / R2 Inde |
| | | | | L1 E2 NCODE 58 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | DC loop / R2 Inde Digital type 2/ R2 Inde |
| | | | | L2 E2 NCODE 6 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | Digital type 3/ R2 Inde (Indian PCM) |
| | | | | L6 E2 NCODE 57 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | Digital type 1/ R2 Inde (numerique Inde 3RT) |
| | | | | L7 E2 NCODE 7 |
| | | |-------+------------------------------------------------|
| | | | E/S/M | Q421 mixte/Decadic clav |
| | | | | L12 E3 NCODE 47 |
| | | |-------+------------------------------------------------|
| | | | ./S/. | For internal use routing to MPNA |
| | | | | L1 E12 NCODE 0 |
| | |----+-------+------------------------------------------------|
| | | 2 | E/S/. | E et M / R2 Inde |
| | | | | L1 E2 NCODE 58 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | DC loop / R2 Inde Digital type 2/ R2 Inde |
| | | | | L2 E2 NCODE 6 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | Digital type 3/ R2 Inde (Indian PCM) |
| | | | | L6 E2 NCODE 57 |
+---------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 87/145 !
+---------------------------------------------------------------------------------+
+---------------------------------------------------------------------------}
| (P) TITLE : Outgoing circuit group management |
|---------------------------------------------------------------------------|
| Parameter |CIRCUIT| |
|------------------| GROUP | MEANING |
| Symbol | Value | TYPE | |
|---------+--------+-------+------------------------------------------------|
| CTA = | VSGn | E/S/M | Signalling variant |
| | | | (n is from 1 to 15) |
| |n =+----+-------+------------------------------------------------|
| | | 2 | E/S/. | Digital type 1/ R2 Inde (numerique Inde 3RT) |
| | | | | L7 E2 NCODE 7 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | Digital type 1/ Decadic (numerique Inde 3RT) |
| | | | | L7 E3 NCODE 7 |
| | | |-------+------------------------------------------------|
| | | | ./S/. | For internal use routing to IP or DAM |
| | | | | L1 E12 NCODE 0 |
| | |----+-------+------------------------------------------------|
| | | 3 | E/S/. | E et M / R2 Inde |
| | | | | L1 E2 NCODE 58 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | DC loop / R2 Inde Digital type 2/ R2 Inde |
| | | | | L2 E2 NCODE 6 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | Digital type 3/ R2 Inde (Indian PCM) |
| | | | | L6 E2 NCODE 57 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | Digital type 1/ R2 Inde (numerique Inde 3RT) |
| | | | | L7 E2 NCODE 7 |
| | |----+-------+------------------------------------------------|
| | | 4 | E/S/. | E et M / R2 Inde |
| | | | | L1 E2 NCODE 58 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | DC loop / R2 Inde Digital type 2/ R2 Inde |
| | | | | L2 E2 NCODE 6 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | Digital type 3/ R2 Inde (Indian PCM) |
| | | | | L6 E2 NCODE 57 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | Digital type 1/ R2 Inde (numerique Inde 3RT) |
| | | | | L7 E2 NCODE 7 |
| | |----+-------+------------------------------------------------|
| | | 5 | E/S/M | Q421 mixte/R2 INT CCITT |
| | | | | L12 E2 NCODE 47 |
+---------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 88/145 !
+---------------------------------------------------------------------------------+
+---------------------------------------------------------------------------}
| (P) TITLE : Incoming circuit group management |
|---------------------------------------------------------------------------|
| Parameter |CIRCUIT| |
|------------------| GROUP | MEANING |
| Symbol | Value | TYPE | |
|---------+--------+-------+------------------------------------------------|
| CTA = | VSGn | E/S/M | Signalling variant |
| | | | (n is from 1 to 15) |
| |n =+----+-------+------------------------------------------------|
| | | 0 | E/S/M | CSE Reveil Subscriber |
| | | | | L1 E1 NCODE 0 |
| | | |-------+------------------------------------------------|
| | | | E/S/M | PCM Subscriber |
| | | | | L2 E1 NCODE 33 |
| | | |-------+------------------------------------------------|
| | | | E/S/M | Analog Subscriber |
| | | | | L3 E1 NCODE 0 |
| | | |-------+------------------------------------------------|
| | | | E/S/M | Digital Subscriber |
| | | | | L4 E1 NCODE 0 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | E et M / Decadic |
| | | | | L1 E3 NCODE 58 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | DC loop / Decadic Digital type 2/ Decadic |
| | | | | L2 E3 NCODE 6 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | DC loop 3 fils/ Decadic |
| | | | | L3 E3 NCODE 6 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | Manual board (Trunk Offering)Digital type 2 |
| | | | | L4 E3 NCODE 6 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | Manual board (Manual Hold ) Digital type 2 |
| | | | | L5 E3 NCODE 6 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | Digital type 3/Decadic (Indian PCM) |
| | | | | L6 E3 NCODE 57 |
| | | |-------+------------------------------------------------|
| | | | E/S/M | ISUP INTERNATIONAL |
| | | | | L9 E7 NCODE 70 |
| | | |-------+------------------------------------------------|
| | | | E/S/M | ISUP V2 Inde |
| | | | | L10 E7 NCODE 70 |
| | | |-------+------------------------------------------------|
| | | | E/S/M | IN-ER1 |
| | | | | L1 E12 NCODE 0 |
+---------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 89/145 !
+---------------------------------------------------------------------------------+
+---------------------------------------------------------------------------}
| (P) TITLE : Incoming circuit group management |
|---------------------------------------------------------------------------|
| Parameter |CIRCUIT| |
|------------------| GROUP | MEANING |
| Symbol | Value | TYPE | |
|---------+--------+-------+------------------------------------------------|
| CTA = | VSGn | E/S/M | Signalling variant |
| | | | (n is from 1 to 15) |
| |n =+----+-------+------------------------------------------------|
| | | 0 | E/S/M | IN-CS1 |
| | | | | L2 E12 NCODE 0 |
| | | |-------+------------------------------------------------|
| | | | E/S/M | ISUP V2 Inde Boucle |
| | | | | L10 E13 NCODE 0 |
| | |----+-------+------------------------------------------------|
| | | 1 | E/S/. | E et M / R2 Inde |
| | | | | L1 E2 NCODE 58 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | DC loop / R2 Inde Digital type 2/ R2 Inde |
| | | | | L2 E2 NCODE 6 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | Digital type 3/ R2 Inde (Indian PCM) |
| | | | | L6 E2 NCODE 57 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | Digital type 1/ R2 Inde (numerique Inde 3RT) |
| | | | | L7 E2 NCODE 7 |
| | | |-------+------------------------------------------------|
| | | | E/S/M | Q421 mixte/Decadic clav |
| | | | | L12 E3 NCODE 47 |
| | |----+-------+------------------------------------------------|
| | | 2 | E/S/. | E et M / R2 Inde |
| | | | | L1 E2 NCODE 58 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | DC loop / R2 Inde Digital type 2/ R2 Inde |
| | | | | L2 E2 NCODE 6 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | Digital type 3/ R2 Inde (Indian PCM) |
| | | | | L6 E2 NCODE 57 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | Digital type 1/ R2 Inde (numerique Inde 3RT) |
| | | | | L7 E2 NCODE 7 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | Digital type 1/ Decadic (numerique Inde 3RT) |
| | | | | L7 E3 NCODE 7 |
| | |----+-------+------------------------------------------------|
| | | 3 | E/S/. | E et M / R2 Inde |
| | | | | L1 E2 NCODE 58 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | DC loop / R2 Inde Digital type 2/ R2 Inde |
| | | | | L2 E2 NCODE 6 |
+---------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 90/145 !
+---------------------------------------------------------------------------------+
+---------------------------------------------------------------------------}
| (P) TITLE : Incoming circuit group management |
|---------------------------------------------------------------------------|
| Parameter |CIRCUIT| |
|------------------| GROUP | MEANING |
| Symbol | Value | TYPE | |
|---------+--------+-------+------------------------------------------------|
| CTA = | VSGn | E/S/M | Signalling variant |
| | | | (n is from 1 to 15) |
| |n =+----+-------+------------------------------------------------|
| | | 3 | E/S/. | Digital type 3/ R2 Inde (Indian PCM) |
| | | | | L6 E2 NCODE 57 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | Digital type 1/ R2 Inde (numerique Inde 3RT) |
| | | | | L7 E2 NCODE 7 |
| | |----+-------+------------------------------------------------|
| | | 4 | E/S/. | E et M / R2 Inde |
| | | | | L1 E2 NCODE 58 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | DC loop / R2 Inde Digital type 2/ R2 Inde |
| | | | | L2 E2 NCODE 6 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | Digital type 3/ R2 Inde (Indian PCM) |
| | | | | L6 E2 NCODE 57 |
| | | |-------+------------------------------------------------|
| | | | E/S/. | Digital type 1/ R2 Inde (numerique Inde 3RT) |
| | | | | L7 E2 NCODE 7 |
| | |----+-------+------------------------------------------------|
| | | 5 | E/S/M | Q421 mixte/R2 INT CCITT |
| | | | | L12 E2 NCODE 47 |
+---------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 91/145 !
+---------------------------------------------------------------------------------+
3.4.2 STANDARD CATEGORIES (x)

+-------------------------------------------------------------------------+
| |
| (S) TITLE: Circuit group management |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CTA = | RTT | Backwards metering pulse transmission(incoming group)|
| |--------+------------------------------------------------------|
| | | Incoming group: Backwards metering pulse transmission|
| | RTS | providing TR used at source (see FIPAM 'TRTLTI', |
| | | 'TRTLTJ', 'TRTLTK' and 'TRTLTL' record 34) |
| |--------+------------------------------------------------------|
| | TR | Transit operation authorized (incoming group) |
| |--------+------------------------------------------------------|
| | CP | Priority circuit group |
| |--------+------------------------------------------------------|
| | TKO | Special group for operator trunk offering |
| |--------+------------------------------------------------------|
| | CRA | Activity report (coupled with DIS=CRA on the outgoing|
| | | circuit group) |
| |--------+------------------------------------------------------|
| | DTC | Entitlement to meter charging for the circuits |
| | | (incoming circuit group) |
| |--------+------------------------------------------------------|
| | IDI | Identification impossible (incoming circuit group) |
| |--------+------------------------------------------------------|
| | IDT | Automatic immediate charging indication |
| | | (incoming circuit group) |
| |--------+------------------------------------------------------|
| | INSPn | Insertion/substitution of digits in preanalysis |
| | | INSPn implies GENR=E/M |
| | +---+------------------------------------------------------|
| |n = | 0 | Default value: no insertion |
| | |---+------------------------------------------------------|
| | | 1 | Insertion before preanalysis of the INDR digits |
| | |---+------------------------------------------------------|
| | | 2 | Insertion after preanalysis of the INDR digits in |
| | | | the RCE row (given by the preanalysis file) if the |
| | | | INS discrimination (given by the preanalysis file) |
| | | | is also present. The presence of this discrimination |
| | | | also enables a specific preanalysis file defined by |
| | | | the FIPAM data: PREAFI to be used |
| |--------+------------------------------------------------------|
| | BL31 | Circuit group discrimination (ISUP V2) authorising |
| | | the block transmission of over 16 digits. |
| | | BL31 excludes GENR=E |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 92/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE : Circuit group management |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CTA = | FMP | Hold function possible |
| |--------+------------------------------------------------------|
| | AECH | Echo canceller present |
| |--------+------------------------------------------------------|
| | AEGR | Transmission of group messages authorized |
| |--------+------------------------------------------------------|
| | AUB | Noise measurement authorized |
| |--------+------------------------------------------------------|
| | DAI | International incoming or outgoing circuit group |
| |--------+------------------------------------------------------|
| | DSE | Half echo suppressor present |
| |--------+------------------------------------------------------|
| | SAT | Satellite indicator |
| |--------+------------------------------------------------------|
| | MFC | Identification request (MF spe. FRA) |
| |--------+------------------------------------------------------|
| | RAA | Access restriction on incoming Transgroupe |
| | | calls |
| |--------+------------------------------------------------------|
| | MOB | CG coming from mobile exchange (CCM /SSUTR2) |
| |--------+------------------------------------------------------|
| | PX | Interdiction of charging messages transmission |
| | | to the MSC |
| |--------+------------------------------------------------------|
| | DCA | Incoming trunk with accounting |
| |--------+------------------------------------------------------|
| | CNXn | CNXn category |
| | +---+------------------------------------------------------|
| |n = | 1 | Digital circuit group, ISDN signalling |
| | |---+------------------------------------------------------|
| | | 2 | Analogue circuit group, non-ISDN signalling |
| | |---+------------------------------------------------------|
| | | 3 | Digital circuit group, non-ISDN signalling |
| | |---+------------------------------------------------------|
| | | 4 | Analogue circuit group, ISDN signalling |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 93/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE : Circuit group management |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CTA = | RIDRX | Allows the identities received to be forced to |
| | | +restricted disclosure+ (calling subscriber no., |
| | | NDS no., initial called subscriber no., |
| | | no. of the last person forwarding call) |
| |--------+------------------------------------------------------|
| | DCMi | Circuit group requiring digital circuit multiplier |
| | | equipment. |
| | 1<i<7 | The NCODE is supplied by NCMEi of the FIPAM |
| | +---+------------------------------------------------------|
| |i = | 1 | NCODE = 93 |
| | |---+------------------------------------------------------|
| | | 2 | NCODE = 70 |
| | |---+------------------------------------------------------|
| | | 3 | NCODE = 71 |
| | |---+------------------------------------------------------|
| | |4/7| Available |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 94/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (S) TITLE : Circuit group management |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CTA = | TIDn | Kind of identification of called party |
| |--------+------------------------------------------------------|
| |n = 0 | Default value |
| | | The calling party identity received on the |
| | | trunk is controlled by the network. |
| | | That identity can be forwarded. If no identity |
| | | has been received, INDS, if it exists, is |
| | | forwarded. |
| | | The calling party identity received on the circuit |
| | | group is also used to make the detailed billing |
| | | item. By default, the INDS, if it exists, replaces |
| | | it. |
| | | The calling party identity put in the |
| | | accounting item is INDT (calling party identity |
| | | received). |
| |--------+------------------------------------------------------|
| |n = 1 | No calling party Id request is sent |
| | | backwards. |
| | | The forwarded identity is INDS. |
| | | The identity put in the detailed billing item or |
| | | accounting item is INDT. |
| |--------+------------------------------------------------------|
| |n = 2 | The calling party identity received on the trunk |
| | | is not controlled. |
| | | The forwarded identity is INDS. |
| | | The identity put in the detailed billing item or |
| | | accounting item is composed with INDT and, |
| | | eventually, the identity received. |
| |--------+------------------------------------------------------|
| |n = 3 | The calling party identity received on the trunk |
| | | is controlled by the network. |
| | | This identification can be forwarded. |
| | | If no identity has been received, the INDS, if it |
| | | exists, is forwarded. |
| | | The identity put in the detailed billing item or |
| | | accounting item is composed with INDT and, |
| | | eventually, the identity received. |
+-------------------------------------------------------------------------+

NOTE(S): The TIDn trunk group category only occurs in the event ofplissage
filling of communications detail articles in standard TLV format.
Consequently, the TIDn trunk group category is not used by an oper-
ator who uses the standard TLV format for communications detail ar-
ticles and who never emits a caller ID which is initialised with
the INDS trunk group category.

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 95/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (A) TITLE : Circuit group management |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CTA = | FDn | Detailed billing for incoming calls |
| | 0-n-7 | |
| |--------+------------------------------------------------------|
| | SRn | Restirction categorie |
| | 0-n-15 | |
| |--------+------------------------------------------------------|
| | ATn | Routing and charging categories associated with the |
| | | incoming circuit group n < 32 used if TNX(FIPAM)=1 |
| | 1-n-32 | n = 1 default value |
| |--------+------------------------------------------------------|
| | ZGn | Geographical area associated with the incoming |
| | | circuit group, n from MXZG(FIPAM) to 255 |
| |1-n-255 | n = 1 default value |
| |--------+------------------------------------------------------|
| | CACn | Routing category associated with the incoming circuit|
| | | group, n from MXCAC(FIPAM) to 64, used if |
| | | TNX(FIPAM)=0 |
| | 1-n-64 | n = 1 default value |
| |--------+------------------------------------------------------|
| | CAXn | Charging category associated with the incoming |
| | | circuit group, n from MXCAX(FIPAM) to 64, used if |
| | | TNX(FIPAM)=0 |
| | 1-n-64 | n = 1 default value |
| |--------+------------------------------------------------------|
| | ZTXn | Charging category associated with the incoming |
| | | circuit group, n from MXZTX(FIPAM) to 128, used if |
| | | TNX(FIPAM)=0 |
| | 1-n-128| n = 1 default value |
| |--------+------------------------------------------------------|
| | FRIn | Standard discriminations (n is from 1 to 32) |
| | | IN-CS1 service access category |
| | 1-n-32 | n = 1 default value |
| |--------+------------------------------------------------------|
| | SEPj | Profile of the pooled EC to be inserted in a fixed |
| | | environment |
| |--------+------------------------------------------------------|
| | AEPj | Profile of the pooled EC to be inserted in a GSM |
| | | environment |
| |--------+------------------------------------------------------|
| | RAi | Call barring on an incoming circuit group |
| | | Call rejected if ACH has also the RAi discrimination |
+-------------------------------------------------------------------------|

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 96/145 !
+---------------------------------------------------------------------------------+
+---------------------------------------------------------------------+
| |
| (A) TITLE : N7 circuit group management |
| |
|---------------------------------------------------------------------|
| | | |
| Sigle | Valeur | Signification |
| | | |
|--------+---------------+--------------------------------------------|
| CTA = | PROFi | Screening profile |
| | +-------+--------------------------------------------|
| | i = | 0 | Default screening /F0 |
| | |-------+--------------------------------------------|
| | | 1 | CCBS screening and F1 filter |
| | | | Incoming and outgoing circuit groups |
| | |-------+--------------------------------------------|
| | | 2 | CCBS screening and F4 filter |
| | | | Incoming and outgoing circuit groups |
| | |-------+--------------------------------------------|
| | | 3 | Screening of CLIP service |
| | | | Outgoing circuit group |
| | |-------+--------------------------------------------|
| | | 4 | Screening of Redirection Information param.|
| | | | Incoming circuit group |
| | |-------+--------------------------------------------|
| | | 5 | Screening of Location Number |
| | | | Outgoing circuit group |
| | |-------+--------------------------------------------|
| | | 6 | Screening of Redirecting Number and |
| | | | Original Called Number. Retansmission |
| | | | forbidden on outgoing circuit group |
| | |-------+--------------------------------------------|
| | | 7 | Screening of Redirecting Number and |
| | | | Original Called Number. Retansmission |
| | | | enabled on outgoing circuit group |
| | |-------+--------------------------------------------|
| | | 8 | Screening of Redirecting Number and Orig. |
| | | | Called Number. Retransmission with forced |
| | | | 'Presentation restricted' on outgoing FSC |
| | |-------+--------------------------------------------|
| | | 9 | Screening of MCID query |
| | | | Incoming circuit group |
| | | | MCID emission forbidden |
| | |-------+--------------------------------------------|
| | | 10 | Screening of Col_REQUEST |
| | | | Incoming and ougoing circuit groups |
| | | | Emission/reception of parameter forbidden |
| | |-------+--------------------------------------------|
| | | 11 | Screening of CGU service |
| | | | Outgoing circuit group |
| | | | Center which does not handle this service |
| | |-------+--------------------------------------------|
| | |-------+--------------------------------------------|
| | | 15 | |
+---------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 97/145 !
+---------------------------------------------------------------------------------+
3.4.3 STANDARD DISCRIMINATIONS (x)

+-------------------------------------------------------------------------}
| |
| (P) TITLE : Outgoing circuit group management |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CTA = | DF1 | Oclix fault for V/V |
| |--------+------------------------------------------------------|
| | DF2 | |
| |--------+------------------------------------------------------|
| | DFAn | Standard discriminations (n is from 1 to 15) |
| | +----+------------------------------------------------------|
| |n =| 0 | Default value |
| | |----+------------------------------------------------------|
| | | 1 | Send DRS |
| | |----+------------------------------------------------------|
| | | 2 | |
| | |----+------------------------------------------------------|
| | | 3 | |
| | |----+------------------------------------------------------|
| | | 4 | |
| | |----+------------------------------------------------------|
| | | 5 | |
| | |----+------------------------------------------------------|
| | | 6 | |
| | |----+------------------------------------------------------|
| | | 7 | |
| | |----+------------------------------------------------------|
| | | 8 | |
| | |----+------------------------------------------------------|
| | | 9 | |
| | |----+------------------------------------------------------|
| | | 10 | |
| | |----+------------------------------------------------------|
| | | 11 | |
| | |----+------------------------------------------------------|
| | | 12 | |
| | |----+------------------------------------------------------|
| | | 13 | |
| | |----+------------------------------------------------------|
| | | 14 | |
| | |----+------------------------------------------------------|
| | | 15 | |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 98/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------}
| |
| (P) TITLE : Outgoing circuit group management |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CTA = | DFBn | Standard discriminations (n is from 1 to 15) |
| | +----+------------------------------------------------------|
| |n =| 0 | Default value |
| | |----+------------------------------------------------------|
| | | 1 | |
| | |----+------------------------------------------------------|
| | | 2 | |
| | |----+------------------------------------------------------|
| | | 3 | |
| | |----+------------------------------------------------------|
| | | 4 | No test a release guard for E&-M |
| | |----+------------------------------------------------------|
| | | 5 | |
| | |----+------------------------------------------------------|
| | | 6 | |
| | |----+------------------------------------------------------|
| | | 7 | |
| | |----+------------------------------------------------------|
| | | 8 | Answer reponse = first taxe |
| | |----+------------------------------------------------------|
| | | 9 | |
| | |----+------------------------------------------------------|
| | | 10 | |
| | |----+------------------------------------------------------|
| | | 11 | |
| | |----+------------------------------------------------------|
| | | 12 | |
| | |----+------------------------------------------------------|
| | | 13 | |
| | |----+------------------------------------------------------|
| | | 14 | |
| | |----+------------------------------------------------------|
| | | 15 | |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 99/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------}
| |
| (P) TITLE : Outgoing circuit group management |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CTA = | DFCn | Standard discriminations (n is from 1 to 15) |
| | +----+------------------------------------------------------|
| |n =| 0 | Default value |
| | |----+------------------------------------------------------|
| | | 1 | Forbidden restart |
| | |----+------------------------------------------------------|
| | | 2 | |
| | |----+------------------------------------------------------|
| | | 3 | |
| | |----+------------------------------------------------------|
| | | 4 | |
| | |----+------------------------------------------------------|
| | | 5 | |
| | |----+------------------------------------------------------|
| | | 6 | |
| | |----+------------------------------------------------------|
| | | 7 | |
| | |----+------------------------------------------------------|
| | | 8 | Wait time before send a first digit |
| | |----+------------------------------------------------------|
| | | 9 | |
| | |----+------------------------------------------------------|
| | | 10 | |
| | |----+------------------------------------------------------|
| | | 11 | |
| | |----+------------------------------------------------------|
| | | 12 | |
| | |----+------------------------------------------------------|
| | | 13 | |
| | |----+------------------------------------------------------|
| | | 14 | |
| | |----+------------------------------------------------------|
| | | 15 | |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 100/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------}
| |
| (P) TITLE : Outgoing circuit group management |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CTA = | DFDn | Standard discriminations (n is from 1 to 15) |
| | +----+------------------------------------------------------|
| |n =| 0 | Default value |
| | |----+------------------------------------------------------|
| | | 1 | |
| | |----+------------------------------------------------------|
| | | 2 | |
| | |----+------------------------------------------------------|
| | | 3 | |
| | |----+------------------------------------------------------|
| | | 4 | Transmission of coin box category forbidden on |
| | | | outgoing R2 group |
| | |----+------------------------------------------------------|
| | | 5 | |
| | |----+------------------------------------------------------|
| | | 6 | |
| | |----+------------------------------------------------------|
| | | 7 | |
| | |----+------------------------------------------------------|
| | | 8 | |
| | |----+------------------------------------------------------|
| | | 9 | |
| | |----+------------------------------------------------------|
| | | 10 | |
| | |----+------------------------------------------------------|
| | | 11 | |
| | |----+------------------------------------------------------|
| | | 12 | |
| | |----+------------------------------------------------------|
| | | 13 | |
| | |----+------------------------------------------------------|
| | | 14 | |
| | |----+------------------------------------------------------|
| | | 15 | |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 101/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------}
| |
| (P) TITLE : Outgoing circuit group management |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CTA = | DFEn | Standard discriminations (n is from 1 to 15) |
| | +----+------------------------------------------------------|
| |n =| 0 | Default value |
| | |----+------------------------------------------------------|
| | | 1 | |
| | |----+------------------------------------------------------|
| | | 2 | |
| | |----+------------------------------------------------------|
| | | 3 | |
| | |----+------------------------------------------------------|
| | | 4 | |
| | |----+------------------------------------------------------|
| | | 5 | |
| | |----+------------------------------------------------------|
| | | 6 | |
| | |----+------------------------------------------------------|
| | | 7 | |
| | |----+------------------------------------------------------|
| | | 8 | |
| | |----+------------------------------------------------------|
| | | 9 | |
| | |----+------------------------------------------------------|
| | | 10 | |
| | |----+------------------------------------------------------|
| | | 11 | |
| | |----+------------------------------------------------------|
| | | 12 | |
| | |----+------------------------------------------------------|
| | | 13 | |
| | |----+------------------------------------------------------|
| | | 14 | |
| | |----+------------------------------------------------------|
| | | 15 | |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 102/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------}
| |
| (P) TITLE : Outgoing circuit group management |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CTA = | DFFn | Standard discriminations (n is from 1 to 15) |
| | +----+------------------------------------------------------|
| |n =| 0 | Default value |
| | |----+------------------------------------------------------|
| | | 1 | |
| | |----+------------------------------------------------------|
| | | 2 | |
| | |----+------------------------------------------------------|
| | | 3 | |
| | |----+------------------------------------------------------|
| | | 4 | |
| | |----+------------------------------------------------------|
| | | 5 | |
| | |----+------------------------------------------------------|
| | | 6 | |
| | |----+------------------------------------------------------|
| | | 7 | |
| | |----+------------------------------------------------------|
| | | 8 | |
| | |----+------------------------------------------------------|
| | | 9 | |
| | |----+------------------------------------------------------|
| | | 10 | |
| | |----+------------------------------------------------------|
| | | 11 | |
| | |----+------------------------------------------------------|
| | | 12 | |
| | |----+------------------------------------------------------|
| | | 13 | |
| | |----+------------------------------------------------------|
| | | 14 | |
| | |----+------------------------------------------------------|
| | | 15 | |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 103/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------}
| |
| (P) TITLE : Outgoing circuit group management |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CTA = | DFGn | Standard discriminations (n is from 1 to 15) |
| | +----+------------------------------------------------------|
| |n =| 0 | Default value |
| | |----+------------------------------------------------------|
| | | 1 | |
| | |----+------------------------------------------------------|
| | | 2 | |
| | |----+------------------------------------------------------|
| | | 3 | |
| | |----+------------------------------------------------------|
| | | 4 | |
| | |----+------------------------------------------------------|
| | | 5 | |
| | |----+------------------------------------------------------|
| | | 6 | |
| | |----+------------------------------------------------------|
| | | 7 | |
| | |----+------------------------------------------------------|
| | | 8 | |
| | |----+------------------------------------------------------|
| | | 9 | |
| | |----+------------------------------------------------------|
| | | 10 | |
| | |----+------------------------------------------------------|
| | | 11 | |
| | |----+------------------------------------------------------|
| | | 12 | |
| | |----+------------------------------------------------------|
| | | 13 | |
| | |----+------------------------------------------------------|
| | | 14 | |
| | |----+------------------------------------------------------|
| | | 15 | |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 104/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------}
| |
| (P) TITLE : Outgoing circuit group management |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CTA = | DFHn | Standard discriminations (n is from 1 to 15) |
| | +----+------------------------------------------------------|
| |n =| 0 | Default value |
| | |----+------------------------------------------------------|
| | | 1 | |
| | |----+------------------------------------------------------|
| | | 2 | |
| | |----+------------------------------------------------------|
| | | 3 | |
| | |----+------------------------------------------------------|
| | | 4 | |
| | |----+------------------------------------------------------|
| | | 5 | |
| | |----+------------------------------------------------------|
| | | 6 | |
| | |----+------------------------------------------------------|
| | | 7 | |
| | |----+------------------------------------------------------|
| | | 8 | |
| | |----+------------------------------------------------------|
| | | 9 | |
| | |----+------------------------------------------------------|
| | | 10 | |
| | |----+------------------------------------------------------|
| | | 11 | |
| | |----+------------------------------------------------------|
| | | 12 | |
| | |----+------------------------------------------------------|
| | | 13 | |
| | |----+------------------------------------------------------|
| | | 14 | |
| | |----+------------------------------------------------------|
| | | 15 | |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 105/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------}
| |
| (P) TITLE : Incoming circuit group management |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CTA = | DF1 | Fault OCLIX on trunk V/V |
| |--------+------------------------------------------------------|
| | DF2 | |
| |--------+------------------------------------------------------|
| | DFAn | Standard discriminations (n is from 1 to 15) |
| | +----+------------------------------------------------------|
| |n =| 0 | Default value |
| | |----+------------------------------------------------------|
| | | 1 | |
| | |----+------------------------------------------------------|
| | | 2 | Call national or international |
| | |----+------------------------------------------------------|
| | | 3 | |
| | |----+------------------------------------------------------|
| | | 4 | Send message CHB authorized in ISUP V2 |
| | |----+------------------------------------------------------|
| | | 5 | |
| | |----+------------------------------------------------------|
| | | 6 | |
| | |----+------------------------------------------------------|
| | | 7 | |
| | |----+------------------------------------------------------|
| | | 8 | ND DR impossible a obtenir |
| | |----+------------------------------------------------------|
| | | 9 | |
| | |----+------------------------------------------------------|
| | | 10 | |
| | |----+------------------------------------------------------|
| | | 11 | |
| | |----+------------------------------------------------------|
| | | 12 | |
| | |----+------------------------------------------------------|
| | | 13 | |
| | |----+------------------------------------------------------|
| | | 14 | |
| | |----+------------------------------------------------------|
| | | 15 | |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 106/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------}
| |
| (P) TITLE : Incoming circuit group management |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CTA = | DFBn | Standard discriminations (n is from 1 to 15) |
| | +----+------------------------------------------------------|
| |n =| 0 | Default value |
| | |----+------------------------------------------------------|
| | | 1 | Request identification forbidden in ISUP V2(message |
| | | | INF forbidden) |
| | |----+------------------------------------------------------|
| | | 2 | DTC on called onhook and blocking answer if LST |
| | |----+------------------------------------------------------|
| | | 3 | |
| | |----+------------------------------------------------------|
| | | 4 | |
| | |----+------------------------------------------------------|
| | | 5 | |
| | |----+------------------------------------------------------|
| | | 6 | |
| | |----+------------------------------------------------------|
| | | 7 | |
| | |----+------------------------------------------------------|
| | | 8 | Answer signal = first taxe e |
| | |----+------------------------------------------------------|
| | | 9 | |
| | |----+------------------------------------------------------|
| | | 10 | |
| | |----+------------------------------------------------------|
| | | 11 | |
| | |----+------------------------------------------------------|
| | | 12 | |
| | |----+------------------------------------------------------|
| | | 13 | |
| | |----+------------------------------------------------------|
| | | 14 | |
| | |----+------------------------------------------------------|
| | | 15 | |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 107/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------}
| |
| (P) TITLE : Incoming circuit group management |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CTA = | DFCn | Standard discriminations (n is from 1 to 15) |
| | +----+------------------------------------------------------|
| |n =| 0 | Default value |
| | |----+------------------------------------------------------|
| | | 1 | Restart forbidden |
| | |----+------------------------------------------------------|
| | | 2 | Trink with old protocol |
| | |----+------------------------------------------------------|
| | | 3 | |
| | |----+------------------------------------------------------|
| | | 4 | Send IVT with seizure after incomming decadic group |
| | |----+------------------------------------------------------|
| | | 5 | |
| | |----+------------------------------------------------------|
| | | 6 | |
| | |----+------------------------------------------------------|
| | | 7 | |
| | |----+------------------------------------------------------|
| | | 8 | |
| | |----+------------------------------------------------------|
| | | 9 | |
| | |----+------------------------------------------------------|
| | | 10 | |
| | |----+------------------------------------------------------|
| | | 11 | |
| | |----+------------------------------------------------------|
| | | 12 | |
| | |----+------------------------------------------------------|
| | | 13 | |
| | |----+------------------------------------------------------|
| | | 14 | |
| | |----+------------------------------------------------------|
| | | 15 | |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 108/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------}
| |
| (P) TITLE : Incoming circuit group management |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CTA = | DFDn | Standard discriminations (n is from 1 to 15) |
| | +----+------------------------------------------------------|
| |n =| 0 | Default value |
| | |----+------------------------------------------------------|
| | | 1 | Bloking on hook/off hook (BLOR) in incoming |
| | | | charging center |
| | |----+------------------------------------------------------|
| | | 2 | Inhibition of the aknowledgement of first digit of |
| | | | called number |
| | |----+------------------------------------------------------|
| | | 3 | |
| | |----+------------------------------------------------------|
| | | 4 | |
| | |----+------------------------------------------------------|
| | | 5 | |
| | |----+------------------------------------------------------|
| | | 6 | |
| | |----+------------------------------------------------------|
| | | 7 | |
| | |----+------------------------------------------------------|
| | | 8 | Trunk no7 for EI transit |
| | |----+------------------------------------------------------|
| | | 9 | |
| | |----+------------------------------------------------------|
| | | 10 | |
| | |----+------------------------------------------------------|
| | | 11 | |
| | |----+------------------------------------------------------|
| | | 12 | |
| | |----+------------------------------------------------------|
| | | 13 | |
| | |----+------------------------------------------------------|
| | | 14 | |
| | |----+------------------------------------------------------|
| | | 15 | |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 109/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------}
| |
| (P) TITLE : Incoming circuit group management |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CTA = | DFEn | Standard discriminations (n is from 1 to 15) |
| | +----+------------------------------------------------------|
| |n =| 0 | Default value |
| | |----+------------------------------------------------------|
| | | 1 | Forced release guard no used |
| | |----+------------------------------------------------------|
| | | 2 | Loop of soft origine (BOL) |
| | |----+------------------------------------------------------|
| | | 3 | |
| | |----+------------------------------------------------------|
| | | 4 | IN CS1 loop user origine (BOE) |
| | |----+------------------------------------------------------|
| | | 5 | |
| | |----+------------------------------------------------------|
| | | 6 | |
| | |----+------------------------------------------------------|
| | | 7 | |
| | |----+------------------------------------------------------|
| | | 8 | Send CRA |
| | |----+------------------------------------------------------|
| | | 9 | |
| | |----+------------------------------------------------------|
| | | 10 | |
| | |----+------------------------------------------------------|
| | | 11 | |
| | |----+------------------------------------------------------|
| | | 12 | |
| | |----+------------------------------------------------------|
| | | 13 | |
| | |----+------------------------------------------------------|
| | | 14 | |
| | |----+------------------------------------------------------|
| | | 15 | |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 110/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------}
| |
| (P) TITLE : Incoming circuit group management |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CTA = | DFFn | Standard discriminations (n is from 1 to 15) |
| | +----+------------------------------------------------------|
| |n =| 0 | Default value |
| | |----+------------------------------------------------------|
| | | 1 | Trunk VPN1 |
| | |----+------------------------------------------------------|
| | | 2 | Trunk VPN2 |
| | |----+------------------------------------------------------|
| | | 3 | |
| | |----+------------------------------------------------------|
| | | 4 | Loop EI |
| | |----+------------------------------------------------------|
| | | 5 | |
| | |----+------------------------------------------------------|
| | | 6 | |
| | |----+------------------------------------------------------|
| | | 7 | |
| | |----+------------------------------------------------------|
| | | 8 | Trunk with INDS |
| | |----+------------------------------------------------------|
| | | 9 | |
| | |----+------------------------------------------------------|
| | | 10 | |
| | |----+------------------------------------------------------|
| | | 11 | |
| | |----+------------------------------------------------------|
| | | 12 | |
| | |----+------------------------------------------------------|
| | | 13 | |
| | |----+------------------------------------------------------|
| | | 14 | |
| | |----+------------------------------------------------------|
| | | 15 | |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 111/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------}
| |
| (P) TITLE : Incoming circuit group management |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CTA = | DFGn | Standard discriminations (n is from 1 to 15) |
| | +----+------------------------------------------------------|
| |n =| 0 | Default value |
| | |----+------------------------------------------------------|
| | | 1 | Treatment CAI |
| | |----+------------------------------------------------------|
| | | 2 | Treatment CAI |
| | |----+------------------------------------------------------|
| | | 3 | |
| | |----+------------------------------------------------------|
| | | 4 | Treatment CAI |
| | |----+------------------------------------------------------|
| | | 5 | |
| | |----+------------------------------------------------------|
| | | 6 | |
| | |----+------------------------------------------------------|
| | | 7 | |
| | |----+------------------------------------------------------|
| | | 8 | Treatment CAI |
| | |----+------------------------------------------------------|
| | | 9 | |
| | |----+------------------------------------------------------|
| | | 10 | |
| | |----+------------------------------------------------------|
| | | 11 | |
| | |----+------------------------------------------------------|
| | | 12 | |
| | |----+------------------------------------------------------|
| | | 13 | |
| | |----+------------------------------------------------------|
| | | 14 | |
| | |----+------------------------------------------------------|
| | | 15 | |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 112/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------}
| |
| (P) TITLE : Incoming circuit group management |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| CTA = | DFHn | Standard discriminations (n is from 1 to 15) |
| | +----+------------------------------------------------------|
| |n =| 0 | Default value |
| | |----+------------------------------------------------------|
| | | 1 | Request of category forbidden at the end of the CLI |
| | | | sequence |
| | |----+------------------------------------------------------|
| | | 2 | Call broken if no caller identity |
| | |----+------------------------------------------------------|
| | | 3 | |
| | |----+------------------------------------------------------|
| | | 4 | |
| | |----+------------------------------------------------------|
| | | 5 | |
| | |----+------------------------------------------------------|
| | | 6 | |
| | |----+------------------------------------------------------|
| | | 7 | |
| | |----+------------------------------------------------------|
| | | 8 | |
| | |----+------------------------------------------------------|
| | | 9 | |
| | |----+------------------------------------------------------|
| | | 10 | |
| | |----+------------------------------------------------------|
| | | 11 | |
| | |----+------------------------------------------------------|
| | | 12 | |
| | |----+------------------------------------------------------|
| | | 13 | |
| | |----+------------------------------------------------------|
| | | 14 | |
| | |----+------------------------------------------------------|
| | | 15 | |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 113/145 !
+---------------------------------------------------------------------------------+
4 CALL FORWARDING (x)

4.1 CALL FORWARDING MANAGEMENT (x)

+-----------------------------------------------------------------------+
| |
| (S) TITLE : Call forwarding number management |
| |
|-----------------------------------------------------------------------|
| Parameter | MEANING |
|-------------------+---------------------------------------------------|
| Symbol | Value | |
|---------+---------+---------------------------------------------------|
| RNV | 1 to 255| Call forwarding number |
|---------+---------+---------------------------------------------------|
| PTXA | 0 to 511| Charging parameter associated with calling party |
| | | forwarding |
|---------+---------+---------------------------------------------------|
| SARA | 0 to 15 | Backward signal (tone) associated with calling |
| | | party forwarding |
|---------+---------+---------------------------------------------------|
| CEA | a-b | Event code for the permanent observation |
| | | (a between 0 and 63) and temporary observation |
| | | (b between 0 and 255) associated with calling |
| | | party call forwarding |
|---------+---------+---------------------------------------------------|
| ACHA | 0 - 4095| Routing associated with calling party |
| | | forwarding |
|---------+---------+---------------------------------------------------|
| PTXB | 0 to 511| Charging parameter associated with called party |
| | | forwarding |
|---------+---------+---------------------------------------------------|
| SARB | CE-sar | Backward signal to send, associated with called |
| | | party forwarding |
| | | CE: calling party register code (1 to 15) |
| | | sar: Coding associated with the signal to send |
| | | for that calling party register code |
|---------+---------+---------------------------------------------------|
| ACT | CE-i | Imposed routing (Backward signal and routing) |
| | | CE: calling party register code (1 to 15) i: 0/1 |
| | | i=1, SARB sent and forced use of ACHB |
|---------+---------+---------------------------------------------------|
| CEB | a-b | Event code for the permanent observation |
| | | (a between 0 and 63) and temporary observation |
| | | (b between 0 and 255) associated with called |
| | | party call forwarding |
|---------+---------+---------------------------------------------------|
| ACHB | 0 - 4095| Routing number asociated with called party |
| | | forwarding |
+-----------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 114/145 !
+---------------------------------------------------------------------------------+
+-----------------------------------------------------------------------+
| |
| (S) TITLE : Call forwarding number management |
| |
|-----------------------------------------------------------------------|
| Parameter | MEANING |
|-------------------+---------------------------------------------------|
| Symbol | Value | |
|---------+---------+---------------------------------------------------|
| DIS | NRP | No answer to be sent |
| | MOB | Event codes for observation taken from FIREN file |
| | SUN | Enables one way suspension for calling subscriber |
| | CFT | Connection to announcement or tone when calling |
| | | party is an ISDN subscriber |
| | FNT | If enabled, the B number to be transmitted is in |
| | | national format (associated with NIN) |
| | NIN | Re-transmit initial number |
| | | (ex: to number cancellation centre) |
| | MTX | Modify initial charging information. |
| | INX | Initial dialling to be indexed |
| | | |
|---------+---------+---------------------------------------------------|
| IDN | CE-i | Call forwarded according to reg. code (ORVLA) |
| | | CE: calling party register code (1 to 15) i: 0/1 |
| | | i=1, the call forwarding is performed. |
|---------+---------+---------------------------------------------------|
| CETUP | 1-15 | Pseudo register code associed with |
| | | TUP forwarding (AFIPAM parameter) |
| | | (CETUP=9 default value) |
+-----------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 115/145 !
+---------------------------------------------------------------------------------+
SARB - MAPPING TABLE, SARB AND SIGNAL SENT

+---------------------------------------------------------------------+
| (S) | | |
| |Standard| |
| CODE | signal | MEANING |
| | (SARB) | |
|------------+--------+-----------------------------------------------|
| | | |
| | | |
| Subscriber | | Tone (SARB = TONI code |
| | | of the connected |
| | | tone channel) |
| | | |
|------------+--------+-----------------------------------------------|
| | | |
| R2 | 2 | Transferred subscriber |
| | 3 | Subscriber busy |
| | 4 | Congestion |
| | 5 | Unallocated number |
| | 6 | Subscriber free, call charged |
| | 7 | Subscriber free, call not charged |
| | 8 | Line out of service |
| | 9 | Subscriber intercepted |
| | 12 | Temporarily unavailable |
| | | destination |
| | 13 | Subscriber suspended |
| | 14 | Offering not allowed |
| | 15 | FS operator false manouevre |
| | | |
|------------+--------+-----------------------------------------------|
| | | |
| Decadic | 2 | Subscriber busy |
| | 3 | Congestion |
| | | |
+---------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 116/145 !
+---------------------------------------------------------------------------------+
+--------------------------------------------------------------------------+
| (S) | | | |
| |Standard| | |
| CODE | signal | MEANING | SIGNAL |
| | (SARB) | | sent |
|------------+--------+-------------------------------+--------------------|
| | | | | |
| CCITT N7 | | | Std TUP | Std ISUP |
| | | | | |
| | | | | (cause) |
| | | | | |
| | D'16' | Switching equipment congestion| SEC | REL (42) |
| | D'17' | Circuit group congestion | CGC | REL (34) |
| | D'18' | National network congestion | NNC | REL (34) |
| | D'19' | Call failure, unspecified | CFL | REL (31) |
| | D'20' | Subscriber busy | SSB | REL (17) |
| | D'21' | Unallocated national number | UNN | REL ( 1) |
| | D'22' | Line out of service | LOS | REL (27) |
| | D'23' | Send special information tone | SST | REL ( 4) |
| | D'24' | Misdialled trunk prefix | MPR | REL ( 3) |
| | D'25' | Access barred | ACB | REL (58) |
| | D'26' | ISDN call failure | ACB/ECH | REL (31) |
| | D'27' | Address incomplete | ADI | REL (28) |
| | D'28' | Subscriber out of service | SST | REL (27) |
| | D'29' | Disconnected subscriber | CFL | REL (27) |
| | D'30' | Reserved | | |
| | D'31' | Reserved | | |
| | D'32' | Permanent line | SSB | REL (17) |
| | D'33' | Not used | | |
| | D'34' | Incoming access barred | ACB | REL (88) |
| | D'35' | Digital path not provided | DPN | REL (65) |
| | D'36' | Absent subscriber service | ABS | REL (21) |
| | D'37' | Subscriber line intercepted | SLI | REL (21) |
| | D'38' | Subscriber number changed | CSN | REL (22) |
| | D'39' | Reserved | | |
| | D'40' | Subscriber transferred | ABT | REL (31) |
| | D'41' | CUG service refused | | REL (87) |
| | D'42' | Destination temporarily | | |
| | | unavailable | | |
| | D'43' | Offering not allowed | ECH | REL (31) |
| | | | | |
+--------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 117/145 !
+---------------------------------------------------------------------------------+
+--------------------------------------------------------------------------}
| |
| (P) TITLE : Call forwarding management |
| |
|--------------------------------------------------------------------------|
| Parameter | MEANING |
|-------------------+------------------------------------------------------|
| Symbol | Value | |
|---------+---------+------------------------------------------------------|
| DIS | DVn | Standard discriminations |
| | n 1 to 8| |
| |---------+------------------------------------------------------|
| | DV1 | Artificial occupation |
| |---------+------------------------------------------------------|
| | DV2 | |
| |---------+------------------------------------------------------|
| | DV3 | |
| |---------+------------------------------------------------------|
| | DV4 | |
| |---------+------------------------------------------------------|
| | DV5 | |
| |---------+------------------------------------------------------|
| | DV6 | |
| |---------+------------------------------------------------------|
| | DV7 | |
| |---------+------------------------------------------------------|
| | DV8 | |
+--------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 118/145 !
+---------------------------------------------------------------------------------+
4.2 DESCRIPTION OF CALL FORWARDING (x)

+-----------------------------------------------------------------------+
| |
| (A) TITLE : DESCRIPTION OF CALL FORWARDING |
| |
|-----------------------------------------------------------------------|
|Num. | | |
|Forw.| Forwarding causes | Forwarding processing |
| | | |
|-----+-------------------------------+---------------------------------|
| 1 | Subscriber with cat. DF1 | Vocal annoucement FILM1 |
|-----+-------------------------------+---------------------------------|
| 2 | Subscriber with cat. DF2 | Vocal annoucement FILM 2 |
|-----+-------------------------------+---------------------------------|
| 3 | Subscriber with cat. DF3 | Vocal annoucement FILM 3 |
|-----+-------------------------------+---------------------------------|
| - | idem DF4 -> DF9 | idem FILM 4 -> FILM 9 |
|-----+-------------------------------+---------------------------------|
| 10 | Subscriber with cat. DF10 | Vocal annoucement FILM 10 |
| | | Under-provisioned group |
|-----+-------------------------------+---------------------------------|
| - | idem DF11 -> DF28 | idem FILM 11 -> FILM 28 |
|-----+-------------------------------+---------------------------------|
| 29 | Subscriber with cat. DF29 | Vocal annoucement FILM 29 |
|-----+-------------------------------+---------------------------------|
| 30 | Subscriber with cat. DF30 | Vocal annoucement FILM 30 |
|-----+-------------------------------+---------------------------------|
| 31 | Subscriber with cat. DF31 | Vocal annoucement FILM 31 |
|-----+-------------------------------+---------------------------------|
| 32 | Number not used for calling | |
| | party's SR categoty | |
|-----+-------------------------------+---------------------------------|
| 33 | Area code or prefix does not | |
| | exist | |
| | Incompatible with next digit | |
|-----+-------------------------------+---------------------------------|
| 34 | ACH not allowed to subscribers| |
| | (class I sur ACH) | |
|-----+-------------------------------+---------------------------------|
| 35 | Routing barred to incomming | |
| | trunk calls (class C sur ACH) | |
|-----+-------------------------------+---------------------------------|
| 36 | Call gapping on FPn routing | |
|-----+-------------------------------+---------------------------------|
| 37 | Call gapping on FV routing | |
|-----+-------------------------------+---------------------------------|
| 38 | Call gapping on FDn routing | |
|-----+-------------------------------+---------------------------------|
| 39 | Call gapping on FT routing or | |
| | congestion circuit group | |
+-----------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 119/145 !
+---------------------------------------------------------------------------------+
+-----------------------------------------------------------------------+
| |
| (A) TITLE : DESCRIPTION OF CALL FORWARDING |
| |
|-----------------------------------------------------------------------|
|Num. | | |
|Forw.| Forwarding causes | Forwarding processing |
| | | |
|-----+-------------------------------+---------------------------------|
| 40 | Alarm call service | |
| | Access to speaking clock | |
|-----+-------------------------------+---------------------------------|
| 41 | Unallocated number | |
|-----+-------------------------------+---------------------------------|
| 42 | Absent subs. service (MAR=ABS)| |
|-----+-------------------------------+---------------------------------|
| 43 | Call forwarding | |
| | Artificial busying | |
|-----+-------------------------------+---------------------------------|
| 44 | Call to O/G only subscriber | |
| | Access restr. on SRAn subsc. | |
|-----+-------------------------------+---------------------------------|
| 45 | Alarm call FARV or FCAR | |
| | fill full | |
|-----+-------------------------------+---------------------------------|
| 46 | Facility refused on subsc. | |
| | syntax error | |
|-----+-------------------------------+---------------------------------|
| 47 | Supplementary services | |
| | incompatible | |
|-----+-------------------------------+---------------------------------|
| 48 | System error on facility proc.| |
| | (insufficient resources) | |
|-----+-------------------------------+---------------------------------|
| 49 | Facility rejected, | |
| | Subscriber not entitled | |
|-----+-------------------------------+---------------------------------|
| 50 | Alarm call | |
| | not used if REN 40 used | |
|-----+-------------------------------+---------------------------------|
| 51 | I/C only line or | |
| | subscriber not created | |
|-----+-------------------------------+---------------------------------|
| 52 | Line or group busy on call | |
| | forwarding | |
|-----+-------------------------------+---------------------------------|
| 53 | CENTREX: unallocated | |
| | internal number | |
|-----+-------------------------------+---------------------------------|
| 54 | CENTREX: operator not created | |
| | in the caller's company | |
+-----------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 120/145 !
+---------------------------------------------------------------------------------+
+-----------------------------------------------------------------------+
| |
| (A) TITLE : DESCRIPTION OF CALL FORWARDING |
| |
|-----------------------------------------------------------------------|
|Num. | | |
|Forw.| Forwarding causes | Forwarding processing |
| | | |
|-----+-------------------------------+---------------------------------|
| 55 | Call gapping on congested | |
| | circuit group | |
|-----+-------------------------------+---------------------------------|
| 56 | Maximum number of alternative | |
| | routes reached | |
|-----+-------------------------------+---------------------------------|
| 57 | Congestion following on | |
| | call gapping'appels | |
|-----+-------------------------------+---------------------------------|
| 58 | Failure following call gapping| |
|-----+-------------------------------+---------------------------------|
| 59 | SRC facility: Entry of an | |
| | unauthorized SRn | |
|-----+-------------------------------+---------------------------------|
| 60 | SRC facility - Wrong personal | |
| | counter overflow | |
|-----+-------------------------------+---------------------------------|
| 61 | ACQ subscriber unknowed | |
|-----+-------------------------------+---------------------------------|
| 62 | Filtering on IDSV number | |
| | IN-CS1 / 'CalledAdressValue' | |
|-----+-------------------------------+---------------------------------|
| 63 | Filtering on access number | |
| | IN-CS1 / 'CalledAdressAnSer' | |
|-----+-------------------------------+---------------------------------|
| 64 | Normal failure -cause unspec. | |
| | ISUP failure -cause 31 | |
|-----+-------------------------------+---------------------------------|
| 65 | No calling party identity for | |
| | detailed billing | |
|-----+-------------------------------+---------------------------------|
| 66 | Congestion | |
|-----+-------------------------------+---------------------------------|
| 67 | Fault on outgoing circuit | |
|-----+-------------------------------+---------------------------------|
| 68 | Facility refused due to | |
| | subscriber | |
|-----+-------------------------------+---------------------------------|
| 69 | Connection not allowed | |
|-----+-------------------------------+---------------------------------|
| 70 | Called party intercepted | |
| | (CAT=INT) | |
+-----------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 121/145 !
+---------------------------------------------------------------------------------+
+-----------------------------------------------------------------------+
| |
| (A) TITLE : DESCRIPTION OF CALL FORWARDING |
| |
|-----------------------------------------------------------------------|
|Num. | | |
|Forw.| Forwarding causes | Forwarding processing |
| | | |
|-----+-------------------------------+---------------------------------|
| 71 | Misdialled trunk prefix | |
| | (ISUP - cause 3) | |
|-----+-------------------------------+---------------------------------|
| 72 | Trunk offer refused | |
|-----+-------------------------------+---------------------------------|
| 73 | Called party transferred | |
|-----+-------------------------------+---------------------------------|
| 74 | Called party number changed | |
|-----+-------------------------------+---------------------------------|
| 75 | Called party out of service | |
|-----+-------------------------------+---------------------------------|
| 76 | Unallocated number | |
|-----+-------------------------------+---------------------------------|
| 77 | Alarm call | |
| | Announcement not available | |
|-----+-------------------------------+---------------------------------|
| 78 | ISUP failure -Service | |
| | unavailable (ISUP - cause 63) | |
|-----+-------------------------------+---------------------------------|
| 79 | Vocal annoucement out of serv.| |
|-----+-------------------------------+---------------------------------|
| 80 | Called party intercepted on | |
| | remote part (CAT=INT) | |
|-----+-------------------------------+---------------------------------|
| 81 | Number incomplete | |
|-----+-------------------------------+---------------------------------|
| 82 | Double call forwarding or | |
| | international RVT not allowed | |
|-----+-------------------------------+---------------------------------|
| 83 | Function not available to OP | |
|-----+-------------------------------+---------------------------------|
| 84 | Subscriber suspended | |
|-----+-------------------------------+---------------------------------|
| 85 | Test of tariff | |
|-----+-------------------------------+---------------------------------|
| 86 | ISUP call not used on remote | |
| | part (ISUP cause 5) | |
|-----+-------------------------------+---------------------------------|
| 87 | Destination temporarily | |
| | unavailable | |
|-----+-------------------------------+---------------------------------|
| 88 | Digital path not provided | |
|-----+-------------------------------+---------------------------------|
| 89 | Failure on inf. spinner call | |
+-----------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 122/145 !
+---------------------------------------------------------------------------------+
+-----------------------------------------------------------------------+
| |
| (A) TITLE : DESCRIPTION OF CALL FORWARDING |
| |
|-----------------------------------------------------------------------|
|Num. | | |
|Forw.| Forwarding causes | Forwarding processing |
| | | |
|-----+-------------------------------+---------------------------------|
| 90 | Line out of service - on | |
| | remote part | |
|-----+-------------------------------+---------------------------------|
| 91 | Special information tone send | |
|-----+-------------------------------+---------------------------------|
| 92 | Switching equipment congested | |
|-----+-------------------------------+---------------------------------|
| 93 | National network congested | |
|-----+-------------------------------+---------------------------------|
| 94 | Local network congested | |
|-----+-------------------------------+---------------------------------|
| 95 | Facility accepted | |
|-----+-------------------------------+---------------------------------|
| 96 | Subscriber diverted to | |
| | Do Not Disturbe service | |
|-----+-------------------------------+---------------------------------|
| 97 | Routing to Absent Subsciber | |
| | service (see also REN 42) | |
|-----+-------------------------------+---------------------------------|
| 98 | DND refused, transfer to | |
| | ABS service enable | |
|-----+-------------------------------+---------------------------------|
| 99 | ABS refused, because | |
| | DND enable | |
|-----+-------------------------------+---------------------------------|
| 100 | CENTREX - Operating number is | |
| | NUL in FSOC | |
|-----+-------------------------------+---------------------------------|
| 101 | Facility accepted in remote | |
| | charging (MOTX=TXCD) | |
|-----+-------------------------------+---------------------------------|
| 102 | CENTREX - barred access as | |
| | called party | |
|-----+-------------------------------+---------------------------------|
| 103 | CENTREX - Called party barred | |
|-----+-------------------------------+---------------------------------|
| 104 | CENTREX - Failure in | |
| | Call Pick Up service | |
|-----+-------------------------------+---------------------------------|
| 105 | CENTREX - Callback on Busy | |
| | Circuit Group service | |
+-----------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 123/145 !
+---------------------------------------------------------------------------------+
+-----------------------------------------------------------------------+
| |
| (A) TITLE : DESCRIPTION OF CALL FORWARDING |
| |
|-----------------------------------------------------------------------|
|Num. | | |
|Forw.| Forwarding causes | Forwarding processing |
| | | |
|-----+-------------------------------+---------------------------------|
| 106 | CENTREX - Failure of callback | |
| | on busy Circuit group | |
|-----+-------------------------------+---------------------------------|
| 107 | Signal received =Acces barred | |
|-----+-------------------------------+---------------------------------|
| 108 | Forwarding to Abs. serv. OP | |
|-----+-------------------------------+---------------------------------|
| 109 | UNN tone on facility | |
|-----+-------------------------------+---------------------------------|
| 110 | ISUP failure -unknown cause | |
|-----+-------------------------------+---------------------------------|
| 111 | Not CGU call | |
| | ISUP failure / REL cause 87 | |
|-----+-------------------------------+---------------------------------|
| 112 | Number not used for calling | |
| | party's SR0 category | |
|-----+-------------------------------+---------------------------------|
| 113 | Number not used for calling | |
| | party's SR1 category | |
|-----+-------------------------------+---------------------------------|
| 114 | Number not used for calling | |
| | party's SR2 category | |
|-----+-------------------------------+---------------------------------|
| 115 | Number not used for calling | |
| | party's SR3 category | |
|-----+-------------------------------+---------------------------------|
| 116 | Number not used for calling | |
| | party's SR4 category | |
|-----+-------------------------------+---------------------------------|
| 117 | Number not used for calling | |
| | party's SR5 category | |
|-----+-------------------------------+---------------------------------|
| 118 | Number not used for calling | |
| | party's SR6 category | |
|-----+-------------------------------+---------------------------------|
| 119 | Number not used for calling | |
| | party's SR7 category | |
|-----+-------------------------------+---------------------------------|
| 120 | Number not used for calling | |
| | party's SR8 category | |
+-----------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 124/145 !
+---------------------------------------------------------------------------------+
+-----------------------------------------------------------------------+
| |
| (A) TITLE : DESCRIPTION OF CALL FORWARDING |
| |
|-----------------------------------------------------------------------|
|Num. | | |
|Forw.| Forwarding causes | Forwarding processing |
| | | |
|-----+-------------------------------+---------------------------------|
| 121 | Number not used for calling | |
| | party's SR9 category | |
|-----+-------------------------------+---------------------------------|
| 122 | Number not used for calling | |
| | party's SR10 category | |
|-----+-------------------------------+---------------------------------|
| 123 | Number not used for calling | |
| | party's SR11 category | |
|-----+-------------------------------+---------------------------------|
| 124 | Number not used for calling | |
| | party's SR12 category | |
|-----+-------------------------------+---------------------------------|
| 125 | Number not used for calling | |
| | party's SR13 category | |
|-----+-------------------------------+---------------------------------|
| 126 | Number not used for calling | |
| | party's SR14 category | |
|-----+-------------------------------+---------------------------------|
| 127 | Number not used for calling | |
| | party's SR15 category | |
|-----+-------------------------------+---------------------------------|
| 128 | Outgoing N7 call rejected, | |
| | cause Auto. congestion (RAE) | |
|-----+-------------------------------+---------------------------------|
| 129 | Outgoing N7 call rejected, | |
| | cause Signal congestion (RES) | |
|-----+-------------------------------+---------------------------------|
| 129 | Refus d'appel depart N7 | |
| | pour cause de RES | |
|-----+-------------------------------+---------------------------------|
| 130 | Callback last caller (RDA) | |
| | Subsc. not entitled | |
|-----+-------------------------------+---------------------------------|
| 131 | RDA impossible | |
|-----+-------------------------------+---------------------------------|
| 132 | Call to subsc. in permanent | |
| | Off-Hook condition | |
|-----+-------------------------------+---------------------------------|
| 133 | ISUP / Routing to the | |
| | destination impossible | |
|-----+-------------------------------+---------------------------------|
| 134 | Re-routing to the operator | |
| | (POLAND mil.) | |
|-----+-------------------------------+---------------------------------|
| 135 | Rejeted call on subsc.syntax | |
| | 'Secret Indentite DR App/App' | |
+-----------------------------------------------------------------------+
+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 125/145 !
+---------------------------------------------------------------------------------+
+-----------------------------------------------------------------------+
| |
| (A) TITLE : DESCRIPTION OF CALL FORWARDING |
| |
|-----------------------------------------------------------------------|
|Num. | | |
|Forw.| Forwarding causes | Forwarding processing |
|-----+-------------------------------+---------------------------------|
| 136 | Error on ROC - system cause | |
|-----+-------------------------------+---------------------------------|
| 137 | Error on ROC - calling cause | |
|-----+-------------------------------+---------------------------------|
| 138 | Incomplet number received of | |
| | remote part | |
|-----+-------------------------------+---------------------------------|
| 139 | Congestion cause RSC (Circuit| |
| | Selective Restriction) | |
|-----+-------------------------------+---------------------------------|
| 140 | Rejeted call in ACR | |
| | (Anonimus Call Reject) | |
|-----+-------------------------------+---------------------------------|
| 141 | 'marqued' subscriber | |
|-----+-------------------------------+---------------------------------|
| 142 | No routing to calling carrier | |
| | (cause 2) | |
|-----+-------------------------------+---------------------------------|
| 143 | Invalide TNS (cause 91) | |
|-----+-------------------------------+---------------------------------|
| 144 | Sending of special film if | |
| | ROC call in progress | |
|-----+-------------------------------+---------------------------------|
| 145 | User busy | |
|-----+-------------------------------+---------------------------------|
| 146 | | |
|-----+-------------------------------+---------------------------------|
| 147 | 'Carried' subscriber | |
|-----+-------------------------------+---------------------------------|
|-----+-------------------------------+---------------------------------|
|-----+-------------------------------+---------------------------------|
| 155 | Routing code prohibited on | |
| | incomming circuit | |
|-----+-------------------------------+---------------------------------|
| 156 | Outgoing routing prohibited | |
| | for forwarded calls | |
|-----+-------------------------------+---------------------------------|
|-----+-------------------------------+---------------------------------|
|-----+-------------------------------+---------------------------------|
| 159 | Routing restriction on | |
| | All Call Query service | |
+-----------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 126/145 !
+---------------------------------------------------------------------------------+
+-----------------------------------------------------------------------+
| |
| (A) TITLE : DESCRIPTION OF CALL FORWARDING |
| |
|-----------------------------------------------------------------------|
|Num. | | |
|Forw.| Forwarding causes | Forwarding processing |
| | | |
|-----+-------------------------------+---------------------------------|
| 200 | Filtering of incomming calls | |
|-----+-------------------------------+---------------------------------|
| 201 | Carrier rejected | |
| | Abs. of class ISTA | |
|-----+-------------------------------+---------------------------------|
| 202 | Network congestion | |
|-----+-------------------------------+---------------------------------|
| 203 | Support mode prohibited or | |
| | unavailable | |
|-----+-------------------------------+---------------------------------|
| 204 | Unuased service | |
| | | |
|-----+-------------------------------+---------------------------------|
| 205 | Unused message | |
| | | |
|-----+-------------------------------+---------------------------------|
| 206 | | |
| | | |
|-----+-------------------------------+---------------------------------|
| 207 | | |
| | | |
+-----------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 127/145 !
+---------------------------------------------------------------------------------+
5 CHARGING (x)

+----------------------------------------------------------------------------+
| |
| (S) TITLE: Charging parameter |
| |
|----------------------------------------------------------------------------|
| Cmd parameter | |
|------------------| MEANING |
|Symbol| Value | |
|------+-----------+---------------------------------------------------------|
| PTX | 0 to 511 | Single or multiple charging parameter value |
| | | PTX=0 : No charging with retransmission of answer signal|
|------+-----------+---------------------------------------------------------|
| MDTXX| mnemonic | Charging method |
| | | |
| |-----------+---------------------------------------------------------|
| | Pn | Charging generated locally for automatic calls |
| | 0 to(base)| |
| | | |
| |-----------+---------------------------------------------------------|
| | TMn | Charging generated locally for calls the |
| | 0 to | operator |
| | 255 - base| |
| |-----------+---------------------------------------------------------|
| | IM | Charging by pulses received from forward exchange |
| |-----------+---------------------------------------------------------|
| | RC | Charging by a rate received from forward exchange |
| |-----------+---------------------------------------------------------|
| | TXCD | Charging centralised, without retransmission |
| | | of metering pulses |
| |-----------+---------------------------------------------------------|
| | NTSR | No charging without answer signal to be received |
| |-----------+---------------------------------------------------------|
| | NTSE | No charging without answer signal to be sent |
| |-----------+---------------------------------------------------------|
| | RTI | Charging by receipt of charge code |
|------+-----------+---------------------------------------------------------|
| TYPE | | Type of PTX |
| | | |
| |-----------+---------------------------------------------------------|
| | = 1 | terminal PTX |
| |-----------+---------------------------------------------------------|
| | = 2 | multiple PTX dependent on CAX |
| |-----------+---------------------------------------------------------|
| | = 3 | multiple PTX dependent on CTI |
| |-----------+---------------------------------------------------------|
| | = 4 | multiple PTX dependent on a parametered indexation |
+----------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 128/145 !
+---------------------------------------------------------------------------------+
+----------------------------------------------------------------------------+
| |
| (S) TITLE: Charging parameter |
| |
|----------------------------------------------------------------------------|
| Cmd parameter | |
|------------------| MEANING |
|Symbol| Value | |
|------+-----------+---------------------------------------------------------|
| STY | | Sub-type (associated with TYPE = 4) |
| | | |
| |-----------+---------------------------------------------------------|
| | = SAT | Avoid double satellite hops |
| |-----------+---------------------------------------------------------|
| | = TKO | Offer |
|------+-----------+---------------------------------------------------------|
| TXD | yes | Deferred charging |
| | no | |
|------+-----------+---------------------------------------------------------|
| MCT | 1 to 3 | Method of changing tariff |
| | | |
| | +--------+---------------------------------------------------------|
| | | 1 | No change of tariff during the call |
| | | | (default value) |
| | |--------+---------------------------------------------------------|
| | | 2 | Change of tariff at end of period |
| | |--------+---------------------------------------------------------|
| | | 3 | Change tariff immediately |
|------+-----------+---------------------------------------------------------|
| PTXM | Y-j | multiple PTXM: value of PTX associated with indexation |
| | | i of CIX2, if TNX=1 (type 2 PTX) after CIX2. |
| | Y 0 to 255| PTXM =Y1-j1+Y2-j2+.......+Yk-jk |
| | j 0 to 128| where: Y charge level |
| | | j charge category |
| | | |
|------+-----------+---------------------------------------------------------|
| PTXM | Y-j | multiple PTXM: value of PTX associated with indexation |
| | | i of CAX, if TNX=0 (type 2 PTX) after CAX. |
| | Y 0 to 255| PTXM =Y1-j1+Y2-j2+.......+Yk-jk |
| | j 0 to 128| where: Y charge level |
| | | j charge category |
| | | |
|------+-----------+---------------------------------------------------------|
| PTXM | Y-j | multiple PTXM: value of PTX associated with indexation |
| | | i of CTI, (type 3 PTX) after CTI. |
| | Y 0 to 255| PTXM =Y1-j1+Y2-j2+.......+Yk-jk |
| | j 0 to 128| where: Y charge level |
| | | j charge category |
| | | |
+----------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 129/145 !
+---------------------------------------------------------------------------------+
+--------------------------------------------------------------------------+
| |
| (S) TITLE: Charging parameter |
| |
|--------------------------------------------------------------------------|
| Cmd parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+-------------------------------------------------------|
| CTX = |0 to 255| Charge code defined the parameter MOTX = P'n' |
|---------+--------+-------------------------------------------------------|
| TYP = |0 to 15 | Charge type associated with charging code (CTX) |
| | +----+-------------------------------------------------------|
| |n =| 0 | Charge code not created |
| | |----+-------------------------------------------------------|
| | | 1 | Independent of duration |
| | | | (NTP=0 , TEMPO from 1 to 250, CTXS from 0 to 255) |
| | |----+-------------------------------------------------------|
| | | 2 | Periodic or per unit of conversation without |
| | | | advanced counting |
| | | | (NTP|0 , TEMPO from 1 to 250, CTXS from 0 to 255) |
| | |----+-------------------------------------------------------|
| | | 3 | Periodic or per unit of conversation without |
| | | | advanced counting with initial period different |
| | | | from subsequent periods |
| | | | (NTP|0 , TEMPO = 0 , CTXS from 0 to 255) |
| | |----+-------------------------------------------------------|
| | | 4 | Periodic or per unit of conversation with advanced |
| | | | counting |
| | | | (NTP|0 , TEMPO from 1 to 250, CTXS from 0 to 255) |
| | |----+-------------------------------------------------------|
| | | 5 | Periodic or per unit of conversation with advanced |
| | | | counting |
| | | | with initial period different from subsequent periods |
| | | | (NTP|0 , TEMPO = 0 , CTXS from 0 to 255) |
| | |----+-------------------------------------------------------|
| | | 6 | Not used |
| | |----+-------------------------------------------------------|
| | | 7 | Not used |
| | |----+-------------------------------------------------------|
| | | 8 | Not used |
| | |----+-------------------------------------------------------|
| | | 9 | Not used |
| | |----+-------------------------------------------------------|
| | | 10 | Not used |
| | +------------------------------------------------------------|
| | . . |
| | +------------------------------------------------------------|
| | | 14 | Not used |
| | |----+-------------------------------------------------------|
| | | 15 | Not used |
+--------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 130/145 !
+---------------------------------------------------------------------------------+
+--------------------------------------------------------------------------+
| |
| (S) TITLE: Charging - Charging codes and charging methods |
| |
|--------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+-------------------------------------------------------|
| MTX = | Q-P-P' | Management of charging codes and charging methods |
| | | |
| | | . Q from 0 to 15 : Call connection charge |
| | | |
| | | . P = 0 to 65535 : Metering unit in seconds |
| | | |
| | | . P' = Metering unit |
| | | 350ms -> 10s step of 10ms |
| | | 10 s -> 100s step of 100ms |
| | | 100s -> 1h step of 1s |
| | | |
| | | . Minimum metering unit = 330 ms (P = 0 , P' = 330) |
| | | |
| | | |
|---------+--------+-------------------------------------------------------|
| NTP = |0 to 255| Number of units charged per period |
|---------+--------+-------------------------------------------------------|
| N = |1 to 255| Common denominator of MTX periods |
|---------+--------+-------------------------------------------------------|
| CTXS = |0 to 255| Next charging code |
| | | |
|---------+--------+-------------------------------------------------------|
| TEMPO= |1 to 250| Time during which the CTX charge code applies before |
| | | switching to the next charge code, CTXS. |
| | | TEMPO expressed in units of 1 second. |
|---------+--------+-------------------------------------------------------|
| INDTX= |0 to 255| Charging indicator (N7) |
| | | |
+--------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 131/145 !
+---------------------------------------------------------------------------------+
+--------------------------------------------------------------------------+
| |
| (A) TITLE : Charging parameter |
| |
|--------------------------------------------------------------------------|
| Cmd parameter | |
|------------------| MEANING |
|Symbol | Value | |
|---------+--------+-------------------------------------------------------|
| CPTX | 0 to 3 | Subscriber's meter number |
| | | |
|---------+--------+-------------------------------------------------------|
| GFD = | 0 to 15| Detailed billing group number |
| | | |
|---------+--------+-------------------------------------------------------|
| CIX2 = | 0 to 64| Indexation and charging category |
| | | |
|---------+--------+-------------------------------------------------------|
| STT = | 1 to 31| Typical direction dependent charging scheme |
| | | (By default STT=1) |
|---------+--------+-------------------------------------------------------|
| TYJ | 0 to 7 | Type of day: normal, exceptional or special |
| | | (By default TYJ=1 normal day) |
| | | |
|---------+--------+-------------------------------------------------------|
| DAT | YEAR | The day's date |
| | MONTH | |
| | DAY | |
+--------------------------------------------------------------------------+

+--------------------------------------------------------------------------+
| | | |
| (A) TITLE : Management of types of day for each | STT = | TYJ = |
| Typical charging scheme | | |
|--------------------------------------------------------------------------|
| | | | TF : Tariff number |H0-M0 period start time |
|HR,TF|H1.M1|1 TF 16 | HR Time when the periods |H1.M1 period end time |
| | | | ends. |20 periods maximum |
| | | | (periods must end at | |
| | | | 24h00). | |
|-----+-----+--------+-----------------------------------------------------|
| | | | |
| |-----+--------+-----------------------------------------------------|
| | | | |
| | | | |
| |-----+--------+-----------------------------------------------------|
| | | | |
+--------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 132/145 !
+---------------------------------------------------------------------------------+
6 TONES AND FREQUENCIES (x)

6.1 TONES (x)

The NTONA parameter of the MMCs is deduced from the N_TONA number in the fol-
lowing way:
NTONA = N_TONA - 128. (P)

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 133/145 !
+---------------------------------------------------------------------------------+
+-----------------------------------------------------------------------+
| |
| (P) TITLE : Tones management |
| |
|-----------------------------------------------------------------------|
|NTO-|FREQUENCIES|TONI| LEVEL | LEVEL | TIMING | USE |
| NA | SENT Hz |CODE|F1 dBm0|F2 dBm0| t=transm. | |
|----+-----------+----+-------+-------+------------+--------------------|
| 128| | .. | | | | Idle code |
| | | | | | | |
| 129| | .. | | | | |
| | | | | | | |
| 130| | .. | | | | |
| | | | | | | |
| 131| | .. | | | | |
| | | | | | | |
| 132| | .. | | | | |
| | | | | | | |
| 133| | .. | | | | |
| | | | | | | |
| 134| | .. | | | | |
| | | | | | | |
| 135| | .. | | | | |
| | | | | | | |
| 136| | .. | | | | |
| | | | | | | |
| 137| | .. | | | | |
| | | | | | | |
|----+-----------+----+-------+-------+------------+--------------------|
| 138| | .. | | | | |
|----+-----------+----+-------+-------+------------+--------------------|
| 139| | .. | | | | |
|----+-----------+----+-------+-------+------------+--------------------|
| 140| 950 | .. | -3 | | e : 0.33s | CCITT special |
| | 1400 | | -3 | | s : 0.03s | information tone |
| | 1800 | | -3 | | e : 0.33s | |
| | | | | | s : 0.03s | |
| | | | | | e : 0.33s | |
| | | | | | s : 1s | |
|----+-----------+----+-------+-------+------------+--------------------|
| 141| 1140 + 780| .. | -8 | -8 | Continuous| RF seizure failure |
| | | | | | | (A4 of the R2 code)|
|----+-----------+----+-------+-------+------------+--------------------|
| 142| 400 | .. | -3 | | e : 0.25s | Hold tone |
| | | | | | s : 0.25s | |
| | | | | | e : 0.25s | |
| | | | | | s : 3,25s | |
|----+-----------+----+-------+-------+------------+--------------------|
| 143| 400 | .. | -3 | | e : 2.8s | NU tone |
| | | | | | s : 0.2s | |
+-----------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 134/145 !
+---------------------------------------------------------------------------------+
+------------------------------------------------------------------------+
| |
| (P) TITLE : Tones management |
| |
|------------------------------------------------------------------------|
|NTO-|FREQUENCIES|TONI| LEVEL | LEVEL | TIMING | USE |
| NA | SENT Hz |CODE|F1 dBm0|F2 dBm0| t=transm. | |
|----+-----------+----+-------+-------+------------+---------------------|
| 144| 800 | 0 | 0 | | continuous | Test program tone |
|----+-----------+----+-------+-------+------------+---------------------|
| 145| 1900 | 1 | -7 | | continuous | Test program tone |
|----+-----------+----+-------+-------+------------+---------------------|
| 146| Blank | 2 | | | | Blank, no tone |
|----+-----------+----+-------+-------+------------+---------------------|
| 147| 800 | 3 | -3 | | continuous | Advance warning tone|
|----+-----------+----+-------+-------+------------+---------------------|
| 148| 400 | 4 | -3 | | e : 1s | Acceptance tone |
| | | | | | s : 4s | |
|----+-----------+----+-------+-------+------------+---------------------|
| 149| 400 | 5 | -3 | -9 | e : 0.375s | Ringing tone |
| | | | | | s : 0.250s | timed by freq. 25 |
| | modulated | | | | e : 0.375s | sender/receiver unit|
| | by 25 | | | | s : 2s | |
|----+-----------+----+-------+-------+------------+---------------------|
| 150| 400 | 6 | -3 | -9 | continuous | Dial tone |
| |mod. by 25 | | | | | |
|----+-----------+----+-------+-------+------------+---------------------|
| 151| 400 | 7 | -3 | | e : 0.75s | Busy tone |
| | | | | | s : 0.75s | |
|----+-----------+----+-------+-------+------------+---------------------|
| 152| 400 | 8 | -3 | | e : 0.1s | Routing tone |
| | | | | | s : 0.9s | |
|----+-----------+----+-------+-------+------------+---------------------|
| 153| 400 + 300 | 9 | -3 | -3 | continuous | Special dial tone |
| | | | | | | or second dial tone |
|----+-----------+----+-------+-------+------------+---------------------|
| 154| 400 | 10 | -3 | -9 | e : 0.2s | Strowger test tone |
| | | | | | s : 0.4s | |
| | modulated | | | | e : 2.0s | |
| | by 25 | | | | s : 0.4s | |
|----+-----------+----+-------+-------+------------+---------------------|
| 155| 400 | 11 | -3 | | e : 0.25s | Congestion tone |
| | | | | | s : 0.25s | |
+------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 135/145 !
+---------------------------------------------------------------------------------+
+------------------------------------------------------------------------+
| |
| (P) TITLE : Tones management |
| |
|------------------------------------------------------------------------|
|NTO-|FREQUENCIES|TONI| LEVEL | LEVEL | TIMING | USE |
| NA | SENT Hz |CODE|F1 dBm0|F2 dBm0| t=transm. | |
|----+-----------+----+-------+-------+------------+---------------------|
| 156| 400 | 12 | -3 | | e : 0.15s | Intrusion tone |
| | | | | | s : 4.95s | |
|----+-----------+----+-------+-------+------------+---------------------|
| 157| 400 | 13 | -3 | | e : 0.2s | Call waiting tone |
| | | | | | s : 0.1s | (timing by ML-MR) |
| | | | | | e : 0.2s | |
| | | | | | s : 7.5s | |
|----+-----------+----+-------+-------+------------+---------------------|
| 158| 3000 | 14 | 0 | | continuous | Howler |
| | | | | | | |
|----+-----------+----+-------+-------+------------+---------------------|
| 159| | 15 | | | | |
+------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 136/145 !
+---------------------------------------------------------------------------------+
6.2 SIGNALLING FREQUENCIES (x)

+----------------------------------------------------------------------+
| |
| (S) TITLE : Signalling management |
| SOCOTEL MF SIGNALLING |
|----------------------------------------------------------------------|
| | | | | | |
|NFSIG| Frequencies sent | Level | Level | Timing | Use |
| | f1 (+ f2) in Hz |f1(dBm0)|f2(dBm0)| | |
|-----+----------------------+--------+--------+-----------+-----------|
| | | | | | |
| 1| 700 + 900 | -10,5 | -10,5 | continuous| digit 1 |
| 2| 700 + 1100 | -10,5 | -9,5 | = | 2 |
| 3| 900 + 1100 | -10,5 | -9,5 | = | 3 |
| 4| 700 + 1300 | -10,5 | -9,5 | = | 4 |
| 5| 900 + 1300 | -10,5 | -9,5 | = | 5 |
| 6| 1100 + 1300 | -10,5 | -9,5 | = | 6 |
| 7| 700 + 1500 | -9,5 | -8,5 | = | 7 |
| 8| 900 + 1500 | -10,5 | -8,5 | = | 8 |
| 9| 1100 + 1500 | -9,5 | -8,5 | = | 9 |
| 10| 1300 + 1500 | -9,5 | -8,5 | = | 10 |
| 11| 700 + 1700 | -10,5 | -8,5 | = | 11 |
| 12| 900 + 1700 | -10,5 | -8,5 | = | 12 |
| 13| 1100 + 1700 | -9,5 | -8,5 | = | 13 |
| 14| 1300 + 1700 | -9,5 | -8,5 | = | 14 |
| 15| 1500 + 1700 | -8,5 | -8,5 | = | 15 |
| 16| | | | | |
| 17| 1900 | -7 | | continuous| Ack. Freq.|
| | | | | | |
| 18| 1400 | 0 | | = | RSA tests |
| | | | | | (answer) |
| | | | | | |
| 19| 1400 | -3,5 | | = | RSA tests |
| | | | | | (transm. |
| | | | | | test) |
| | | | | | |
| 20| 1020+1140 | -11,5 | -11,5 | = | India test|
| | | | | | |
| 21| 800 | -11,5 | | = | India test|
| | | | | | |
| 22| 800 | -8 | | = | India test|
| | | | | | |
+----------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 137/145 !
+---------------------------------------------------------------------------------+
+----------------------------------------------------------------------+
| |
| (S) TITLE : Signalling management |
| CCITT R2 SIGNALLING |
|----------------------------------------------------------------------|
| | | | | | |
|NFSIG| Frequencies sent | Level | Level | Timing | Use |
| | f1 (+ f2) in Hz |f1(dBm0)|f2(dBm0)| | |
|-----+----------------------+--------+--------+-----------+-----------|
| | | | | | |
| 33| 1380 + 1500 | - 8 | - 8 | continuous|R2 fwd 1 |
| 34| 1380 + 1620 | - 8 | - 8 | = | 2 |
| 35| 1500 + 1620 | - 8 | - 8 | = | 3 |
| 36| 1380 + 1740 | - 8 | - 8 | = | 4 |
| 37| 1500 + 1740 | - 8 | - 8 | = | 4 |
| 38| 1620 + 1740 | - 8 | - 8 | = | 6 |
| 39| 1380 + 1860 | - 8 | - 8 | = | 7 |
| 40| 1500 + 1860 | - 8 | - 8 | = | 8 |
| 41| 1620 + 1860 | - 8 | - 8 | = | 9 |
| 42| 1740 + 1860 | - 8 | - 8 | = | 10|
| 43| 1380 + 1980 | - 8 | - 8 | = | 11|
| 44| 1500 + 1980 | - 8 | - 8 | = | 12|
| 45| 1620 + 1980 | - 8 | - 8 | = | 13|
| 46| 1740 + 1980 | - 8 | - 8 | = | 14|
| 47| 1860 + 1980 | - 8 | - 8 | = | 15|
| 48| | | | | |
| 49| 1140 + 1020 | - 8 | - 8 | continuous|R2 bckwd 1 |
| 50| 1140 + 900 | - 8 | - 8 | = | 2 |
| 51| 1020 + 900 | - 8 | - 8 | = | 3 |
| 52| 1140 + 780 | - 8 | - 8 | = | 4 |
| 53| 1020 + 780 | - 8 | - 8 | = | 5 |
| 54| 900 + 780 | - 8 | - 8 | = | 6 |
| 55| 1140 + 660 | - 8 | - 8 | = | 7 |
| 56| 1020 + 660 | - 8 | - 8 | = | 8 |
| 57| 900 + 660 | - 8 | - 8 | = | 9 |
| 58| 780 + 660 | - 8 | - 8 | = | 10|
| 59| 1140 + 540 | - 8 | - 8 | = | 11|
| 60| 1020 + 540 | - 8 | - 8 | = | 12|
| 61| 900 + 540 | - 8 | - 8 | = | 13|
| 62| 780 + 540 | - 8 | - 8 | = | 14|
| 63| 660 + 540 | - 8 | - 8 | = | 15|
| | | | | | |
+----------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 138/145 !
+---------------------------------------------------------------------------------+
+----------------------------------------------------------------------+
| |
| (S) TITLE : Signalling management |
| PUSHBUTTON SIGNALLING AND TESTS |
|----------------------------------------------------------------------|
| | | | | | |
|NFSIG| Frequencies sent | Level | Level | Timing | Use |
| | f1 (+ f2) in Hz |f1(dBm0)|f2(dBm0)| | |
|-----+----------------------+--------+--------+-----------+-----------|
| 64| | | | | |
| 65| 697 + 1209 | - 11 | - 9 | continuous|KLA Dig.1 |
| 66| 697 + 1336 | - 11 | - 9 | = | 2 |
| 67| 697 + 1477 | - 11 | - 9 | = | 3 |
| 68| 770 + 1209 | - 11 | - 9 | = | 4 |
| 69| 770 + 1336 | - 11 | - 9 | = | 5 |
| 70| 770 + 1477 | - 11 | - 9 | = | 6 |
| 71| 852 + 1209 | - 11 | - 9 | = | 7 |
| 72| 852 + 1336 | - 11 | - 9 | = | 8 |
| 73| 852 + 1477 | - 11 | - 9 | = | 9 |
| 74| 941 + 1336 | - 11 | - 9 | = | 10 |
| 75| 941 + 1209 | - 11 | - 9 | = | 11 |
| 76| 941 + 1477 | - 11 | - 9 | = | 12 |
| 77| 697 + 1633 | - 11 | - 9 | = | 13 |
| 78| 770 + 1633 | - 11 | - 9 | = | 14 |
| 79| 852 + 1633 | - 11 | - 9 | = | 15 |
| 80| 800 | 0 | | continuous|Contr. LRX |
| 81| 1900 | - 3,5 | | = |Hypso test |
| 82| 700 | - 9,5 | | = | = |
| 83| 700 | - 14,5 | | = | = |
| 84| 700 | - 18 | | = | = |
| 85| 700 | - 21,5 | | = | = |
| 86| 800 | + 1,5 | | = | = |
| 87| 800 | - 5,5 | | = | = |
| 88| 800 | - 7 | | = | = |
| 89| 2000 | - 12 | | = |4w N7 cont.|
| 90| 2000 | - 3,5 | | = |2w N7 cont.|
| 91| 1780 | - 3,5 | | = |2w N7 cont.|
| 92| 1380 + 1980 | - 18 | - 18 | = |R2 hypso |
| 93| 1020 | 0 | | = |Test N°5 |
| 94| 1020 | - 10 | | = | = |
| 95| 941 + 1633 | - 11 | - 9 | = | |
| | | | | | |
+----------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 139/145 !
+---------------------------------------------------------------------------------+
+----------------------------------------------------------------------+
| |
| (S) TITLE : Signalling management |
| CCITT N° 5 SIGNALLING |
|----------------------------------------------------------------------|
| | | | | | |
|NFSIG| Frequencies sent | Level | Level | Timing | Use |
| | f1 (+ f2) in Hz |f1(dBm0)|f2(dBm0)| | |
|-----+----------------------+--------+--------+-----------+-----------|
| 96| | | | | |
| 97| 700 + 900 | - 7 | - 7 | Continuous| digit 1 |
| 98| 700 + 1100 | - 7 | - 7 | = | 2 |
| 99| 900 + 1100 | - 7 | - 7 | = | 3 |
| 100| 700 + 1300 | - 7 | - 7 | = | 4 |
| 101| 900 + 1300 | - 7 | - 7 | = | 5 |
| 102| 1100 + 1300 | - 7 | - 7 | = | 6 |
| 103| 700 + 1500 | - 7 | - 7 | = | 7 |
| 104| 900 + 1500 | - 7 | - 7 | = | 8 |
| 105| 1100 + 1500 | - 7 | - 7 | = | 9 |
| 106| 1300 + 1500 | - 7 | - 7 | = | 10 |
| 107| 700 + 1700 | - 7 | - 7 | = |spare |
| 108| 900 + 1700 | - 7 | - 7 | = |spare |
| 109| 1100 + 1700 | - 7 | - 7 | = | KP |
| 110| 1300 + 1700 | - 7 | - 7 | = |spare |
| 111| 1500 + 1700 | - 7 | - 7 | = | ST |
| | | | | | |
| | | | | | |
| | | | | | |
| | | | | | |
| | | | | | |
| | | | | | |
| | | | | | |
| | | | | | |
| | | | | | |
| | | | | | |
| | | | | | |
| | | | | | |
| | | | | | |
| | | | | | |
| | | | | | |
| | | | | | |
+----------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 140/145 !
+---------------------------------------------------------------------------------+
6.3 INAP NO- SYSTEM FILM NO CORRESPONDENCES (x)

+----------------------------------------------------------------------+
|SCP/SSP | E10B |
|AnnouncementNumber | Announcement number in system values |
|-------------------+--------------------------------------------------|
| 1 | 7 |
| 2 | 8 |
| 3 | 16 |
| 4 | 19 |
| 5 | 17 |
| 6 | 6 |
| 7 | 1 |
| 8 | 20 |
| 9 | 21 |
| 10 | 10 |
| 11 | 11 |
| 12 | 12 |
| 13 | 5 |
| 14 | 13 |
| 15 | 4 |
| 16 | 15 |
| 17 | 22 |
| 18 | 23 |
| 19 | 24 |
| 20 | 25 |
| 21 | 26 |
| 22 | 27 |
| 23 | 28 |
| 24 | 29 |
| 25 | 30 |
| 26 | 9 |
| 27 | 36 |
| 28 | 18 |
| 29 | 31 |
| to | to |
| 33 | 35 |
| 34 | 14 |
| 35 | 37 |
| to | to |
| 49 | 51 |
| 50 | 2 |
| 51 | 3 |
| 52 | 52 |
| .. | .. |
| 127 | 127 |
+----------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 141/145 !
+---------------------------------------------------------------------------------+
+----------------------------------------------------------------------+
|SCP/SSP | E10B |
|ToneNumber | Tone number in system values |
|-------------------+--------------------------------------------------|
| 1 | 151 |
| 2 | 151 |
| 3 | 149 |
| 4 | 152 |
| 5 | 150 |
| 6 | 153 |
| 7 | - |
+----------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 142/145 !
+---------------------------------------------------------------------------------+
7 V5.2 ACCESS MANAGEMENT (x)

+-------------------------------------------------------------------------+
| |
| (P) TITLE V5.2 access management |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| POM | 0 / 1 | PCM setting on the V5.2 interface |
| | | |
|---------+--------+------------------------------------------------------|
| POP | 0 / 1 | PORT setting on START-UP |
| | | |
|---------+--------+------------------------------------------------------|
| RSP | 0 / 1 | PSTN restart procedure |
| | | |
|---------+--------+------------------------------------------------------|
| TETALC | 5 - 15 | Awaiting Allocation Complete timer |
| | | 500 to 1500 ms in steps of 100 ms (5 bits) |
|---------+--------+------------------------------------------------------|
| RPOL | 0 / 1 | Reverse polarity for change to conversation (PSTN) |
| | | |
|---------+--------+------------------------------------------------------|
| TRAC | 0 / 1 | Modification of hang-up timer (PSTN) |
| | | Protocol parameter used or not |
|---------+--------+------------------------------------------------------|
| ATTX | 0 / 1 | AN authorized to stop transmitting charging pulses |
| | | |
|---------+--------+------------------------------------------------------|
| TN1BAS | 1 - 25 | Level 1 timer for CC switchover on fault criteria |
| | | 100 to 2500ms in steps of 100ms (5 bits) |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 143/145 !
+---------------------------------------------------------------------------------+
+-------------------------------------------------------------------------+
| |
| (A) TITLE V5.2 access management |
| |
|-------------------------------------------------------------------------|
| Parameter | |
|------------------| MEANING |
| Symbol | Value | |
|---------+--------+------------------------------------------------------|
| VERS= | 0 | standard AN |
| |--------+------------------------------------------------------|
| | 1 | V52 front end AN |
| |--------+------------------------------------------------------|
| | 2 | V52 SANUM AN |
| |--------+------------------------------------------------------|
| | 3 | CLARINET AN |
| |---------------------------------------------------------------|
| | 4 | V52 India interface with VERSIP = 0 |
| |---------------------------------------------------------------|
| | 5 | V52 India interface with VERSIP = 5 |
| |---------------------------------------------------------------|
| | 6 | V52 India interface with VERSIP = 5 |
| |---------------------------------------------------------------|
| | 10 | V52 India interface with VERSIP = 0 |
| | | ( ring before clip ) |
| |---------------------------------------------------------------|
| | 11 | V52 India interface with VERSIP = 5 |
| | | ( ring before clip ) |
| |---------------------------------------------------------------|
| | 16 | V52 India interface with VERSIP = 12 |
| |---------------------------------------------------------------|
| | 255 | |
|---------+--------+------------------------------------------------------|
| VERSIP | 0 -255 | Pointer to FPPAN |
|---------+--------+------------------------------------------------------|
| IDU | 0 / 1 | Enable/Disable the function: |
| | | Identify the V52 interface and its variant |
|---------+--------+------------------------------------------------------|
| IDM | 0 / 1 | Enable/Disable the function: |
| | | Identify the V52 PCM |
|---------+--------+------------------------------------------------------|
| TCDP | 0 - 63 | Hang-up confirmation time (PSTN) |
|---------+--------+------------------------------------------------------|
| VAL | 0 / 1 | Valid record |
|---------+--------+------------------------------------------------------|
| TTTX | 0 - 31 | Charging pulse duration (PSTN) |
|---------+--------+------------------------------------------------------|
| CSONi | i = | Ringing pattern to be transmitted (PSTN) |
| | I / J | Pattern value in 7 bits, 15 potential codes |
|---------+--------+------------------------------------------------------|
| STAR | 0 / 1 | Activate START-UP on failure of level 2 |
|---------+--------+------------------------------------------------------|
| ABL | 0 / 1 | Non urgent blocking of PCM or subscriber authorized |
+-------------------------------------------------------------------------+

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 144/145 !
+---------------------------------------------------------------------------------+
+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 !
!CIT 3BW74586AAAAPQAHA En 145/145 !
+---------------------------------------------------------------------------------+

Back to the top of the document.


+-----------------+--------------------------------------------------+
! SITE ! !
! ORVAULT ! TECHNICAL DIVISION !
+-----------------+--------------------------------------------------+
! ! !
! ORIGINATORS ! OPERATING DATA !
! ENGEL P ! !
! AHAPOV E ! INDE R25.12 MULTI OPERATORS !
! ! !
! ! REDA - (IN/IND) !
+-----------------+--------------------------------------------------+
+--------------------------------------------------------------------+
! DOMAIN : ALCATEL E10B !
! DIVISION : Software documentation !
! RUBRIC : TAP - Commons !
! TYPE : Sundry documents !
! DISTRIB. CODES INTERNAL : 9999 EXTERNAL : 900000 !
+--------------------------------------------------------------------+

DISTRIBUTION

ABSTRACT

Use of data for translator, charging and traffic management processor, marker
and call handling processor for OCB283 E10B exchanges.

+--------------------------------------------------------------+
! APPROVALS !
+-------+-----------------+------------------+-----------------+
! Name ! FLOCH JL ! GATINEAU G. ! !
! App. ! ! ! !
! ! ! ! !
+-------+-----------------+------------------+-----------------+

REVIEW

Relecture le 03-12-02 by author

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 Status VALIDATED !
!CIT 3BW74586AAAAPQAHA En Y 1/4 !
+---------------------------------------------------------------------------------+
REFERENCE DOCUMENTS

3BW74585AAAAPJDCB : FDAF INDE


3BW32386AAAADAHB : Plan Documentaire DP1-DP2

HISTORY

01.EN of 01-09-17

Creation

02.EN of 02-04-19

RT 01LEX100922, CE.520

03.EN of 02-07-16
FA 3BW74585AAAAPJDCB.04

04.EN of 02-08-20 se | jour


AFR OCBA01FAG077497
prendre en compte le fichier des tonalit§es

05.EN of 02-09-13
AFR OCBA01FAG078315
Mise | jour des valeurs pour overlap

06.EN of 02-10-14
Introduction de l'op§rateur VSNL

07.EN of 03-01-21
AFR OCBA01FAG084602 TYFA TYPU Centrex
D§finition de 'information VERSIO pour interface V52
Suppression ISUP V2 International
Description des discriminations DFD1 et DFH1
Modification de la d§finition NBA
Ajout des pr§analyses manquantes

08.EN of 03-06-17
AFR OCBA01FAG100476
Prise en compte de la discri DQ3 fct 3
Prise en compte de §volution des trames standard
AFR OCBA01CAG110284
Ajout discri de faisceau fct.48 Call broken if no caller identity
AFR OCBA01CAG111390
Cr§ation profils V52 sp§cifique AN

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 Status VALIDATED !
!CIT 3BW74586AAAAPQAHA En Y 2/4 !
+---------------------------------------------------------------------------------+
FOR INTERNAL USE ONLY

BCOM LOCALISATION: OCBXARF.BBA.D74586AAPQ.FXYDCE.SZZ252.8

ASTRID LOCALISATION: DP1/Prod.OCB/Affaires/Doc.Etude/R25.2/Production SD-SR


(FE1A42DV)

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 Status VALIDATED !
!CIT 3BW74586AAAAPQAHA En Y 3/4 !
+---------------------------------------------------------------------------------+
LIST OF FILES

SYSTEM FILES
BRBODYAA.DIADCE: Document organisation file (chapter headings,
pagination,etc)
BRSABOAA.DIADCE: General subscriber operation parameters
BRSABMAA.DIADCE: General subscriber parameters associated with the marks
BRSABTAA.DIADCE: General subscriber parameters associated with the TYPE
BRSABCAA.DIADCE: General subscriber parameters associated with the CATegory
BRSCTXAA.DIADCE: General company parameters (Centrex)
BRSPREAA.DIADCE: General preanalysis operation parameters
BRSANAAA.DIADCE: General analysis operation parameters
BRSACHAA.DIADCE: General routing operation parameters
BRSAFIAA.DIADCE: Routing filtering parameters
BRSFACAA.DIADCE: Facility type routing
BRSATYAA.DIADCE: General parameters depending on the type of routing
BRSFSCAA.DIADCE: General circuit group operation parameters
BRSFN7AA.DIADCE: No.7 circuit group operation parameters
BRSFCAAA.DIADCE: Circuit group category operation parameters
BRSRENAA.DIADCE: General forwarding operation parameters
BRSECHAA.DIADCE: Call failure processing
BRSTAXAA.DIADCE: General charging parameters
BRSTONAA.DIADCE: General parameters describing the frequencies
BRSINFAA.DIADCE: INAP No. and System Film No. correspondence

COUNTRY FILES
These files are updated in the project/FDAF framework
BRPABTAA.DIADCE: Subscriber type Country parameters
BRPABCAA.DIADCE: Subscriber category Country parameters
BRPCXSAA.DIADCE: Company parameters (Centrex)
BRPPREAA.DIADCE: Preanalysis operation Country parameters
BRPANAAA.DIADCE: Analysis operation Country parameters
BRPACHAA.DIADCE: Routing operation Country parameters
BRPFSSAA.DIADCE: Circuit group operation Country parameters -SIG
BRPFSVAA.DIADCE: Circuit group operation Country parameters -VSG
BRPFSBAA.DIADCE: Circuit group operation Country parameters -DISC
BRPRENAA.DIADCE: Forwarding operation Country parameters
BRPTONAA.DIADCE: Country tones description
BRPV52AA.DIADCE: V52 access management

CONTRACT FILES
Files describing the data to be completed by DR in agreement with the opera-
tor
BRAABTAA.DIADCE: Subscriber type Contract parameters
BRAABCAA.DIADCE: Subscriber category Contract parameters
BRAANAAA.DIADCE: Analysis operation Contract parameters
BRAACHAA.DIADCE: Routing operation Contract parameters
BRAFSCAA.DIADCE: Circuit group operation Contract parameters
BRARENAA.DIADCE: Forwarding operation Contract parameters
BRATAXAA.DIADCE: Charging operation Contract parameters
BRACXCAA.DIADCE: User category country (Centrex)
BRACXTAA.DIADCE: User type country (Centrex)
BRACTXAA.DIADCE: Contract companie parameters (Centrex)
BRAV52IN.DIADCE: V52 access management

+---------------------------------------------------------------------------------+
! OPERATING DATA !
! INDE R25.12 MULTI OPERATORS !
! REDA - (IN/IND) !
! ED 08 03-12-02 Status VALIDATED !
!CIT 3BW74586AAAAPQAHA En Y 4/4 !
+---------------------------------------------------------------------------------+