Educational Control Products Ph. (818) 703-0802
1 Buckskin Court, Bell Canyon, CA 91307 fax (818) 703-6040
USA email: hap @ecpsystems.com
WWW.ECPSYSTEMS.COM
INSTRUCTION FOR. SOFTWARE/HARDWARE INSTALLATION
For
MODEL 730,The Magnetic Levitation Apparatus
With
PCI bus Version of ECP DSP Board when installing in 64 bit version Windows 7
Please carry out the following steps to commission your new ECP PCI bus DSP Board
Step 1- ECP Controls Executive Version 5.x Installation for PCI DSP Board:
Ll Do not physically i
1.2- Make sure that your PC’s Version of Windows Operatin
64-bit version of Windows Vista or Windows 7.
3. Make sure that you log on your PC as “Windows Administrator User”. Insert the
supplied ECP Executive Software Installation CD in the CD device of your
computer. Locate the directory .mxxximxxx_cn\Disk| (xxx stands for the 3
digit ECP Model number) on the CD. Then “Run” SETUP.EXE (For Windows
7 you must RIGHT CLICK on SETUP.EXE and “Run AS Administrator”),
Follow the installation dialog boxes. We strongly recommend that you do not
modify the default path/direciory structure used by the installation program
1.4- This action must be followed by installing the ECP’s DSP 64-bit drivers. To do
so, run the installation file ECP64bitDrivers.msi (For Windows 7 you must
RIGHT CLICK on ECP64bitDrivers.msi and “Run AS Administrator”),
1.8- Once BOTH installations are done (both SETUP.EXE and
ECP64bitDrivers.msi), you must “re-start” your Windows OS after the
installation, Make sure that the Windows OS now has “ECP32.exe” the
Windows Folder Program Files (x86\ECP Systems\en,
1.6 Donot run the ECP32.exe program yet. Now turn off power to your PC.
tall the PCI bus DSP Board into your PC yet.
ystem (OS) is the
Step 2- PCI DSP Board Installation Within your PC: Do not change any jumpers on the DSP.
Board. Take it out of its shipping bag carefully and inspect it for physical damage. Pull through
one end of the supplied 60-pin flat cable into your PC from the back of your PC. Connect the 60-
pin flat cable to the 60-pin male Header located at the edge of the DSP Board. Use both hands in
‘order to make sure that the connection is firm and even (the 60-pin flat cable must be fully
inserted into the 60-pin male Header on the DSP Board with no pins bent). Then, with power to
your PC turned off, insert the Controller card in an empty slot of the PC’s PCI bus making
ECP Model 730 Installation Instructions ~ Windows 7 6abit, 1sure it does not touch PCBs in adjacent slots or the PC mother-board. if
possible, do not use the PCI slot adjacent to an ISA slot (the last PCL slot)
Step 3- First Time ECP Controls Executive Program Operation: With the PCI DSP Board
inside your PC, now turn on power. Since a new hardware has been installed, the Windows
OS's Plug & Play feature should automatically detect the PCI DSP Board. This may take as long,
as a minute after the initial installation. In some cases the automatic “New Hardware” detection
may not take place and you would be prompted to give the path of the “PmacPCI.Sys” driver
file to the Windows OS, After Step 1, depending on the Operating Systems, this file will be in
the following folders by default:
Cawindows\system32\drivers
Now enter the “ECP32” program (procedure below is carried out only once after the initial
program installation)
3.- Click on “Yes” to the Warning message “Coniroller not found. Would you
like t0 setup communications
3.2. When the “PMAC Devices” message box appears, click on “Insert” when
the message “PMAC 0 -PCI0- Plug and play” is highlighted,
33+ Click “OK” when the “Available PMAC Devices” message box shows
“PMAC PCIO".
Click “OK” again. You should now be communicating via the ECP
Controls executive program to the PCI DSP Board.
3.5- Tum off power again, From now on, the “ECP32” program will
automatically detect and communicate to the DSP Board,
3.6- For Overseas Customers Only. With Windows In 2 “Non-American
English” Setting: Enter Windows Control Panel and under Clock,
Language and Region select Change the date, time and number format
and under Numbers, change the Decimal Point from“, to“.”. This is @
very important step otherwise the ECP Executives will NOT work
correctly.
ECP Software compatibility with Windows 7 (64-bit OS)
It is assumed that you had followed the special Windows 7 64-bit OS instructions in Steps 1.3
and 1.4 above. That is before running SETUP.EXE, you had RIGHT CLICKed on SETUP.EXE
and Run AS Administrator.
Now, prior to the first use of the ECP Executive program carry out the following steps:
1- Go to Windows Control Panel
2+ Go to Systems Seew
3 Go to Action Center
4- Change User Account Control Settings to “Never Not
bottom),
* (Move the Dial to the
ECP Model 730 Installation Instructions ~ Windows 7 6abitRunning PMAC DSP 64Bits driver as Non-administrator User
In order to allow the use of the PMAC DSP in non-administrator mode follow these steps:
1) Under START Menu go to RUN
2) Type REGEDT32 (note: this is not REGEDIT)
3) Open Hkey_Local_Machine
4) Open System
5) Open CurrentControlset
6) Open Services
7) Open PMAC
8) Select Permissions in the Security Pull-Down menu
9) Add the Group the user is member of (if it is not present already in the list)
10) Double-Click on the Group and click on the “Full Control” check Box and “Read” Check
Box
11) Exit REGEDT32
‘You do not need to repeat these steps again,
Very Important Power On/Off Sequence & Procedure: To TURN ON power FIRST tun
on the power to your PC and SECOND turn on power to your Amplifier (black) Box. Then enter
any ECP Executive program and under the Utility Menu click on “Reset Controller”. The last
step of resetting the DSP Board via “Reset Cont
option under the Utility Menu MUST be carried out every time you cycle power to the Amplifier
(black) Box.
To TURN OFF power FIRST turn off the power to your Amplifier (black) Box and SECOND to
your PC.
Cable Conncetion to the Amplifier Box & Mechanism: Connect the other end of the 60-
pin flat cable to the 60-pin Header at the back of the black Amplifier Box. Again, use both of
your thumb fingers in order to make sure that the connection is firm and even (the 60-pin flat
‘cable must be fully inserted into the 60-pin male Header on the Amplifier Box with no pins
bent). For the Model 730, also connect the 16-pin flat cable, Ifthe previously supplied gray cable
‘or cables between the ECP mechanism and the black Amplifier Box were disconnected, re
connect the cables end make sure the black end connectors are FULLY TWISTED in for good
connection,
Power Supply Conneetion: Connect the supplied power cord to the Amplifier Box. Turn on the
Amplifier Box using the black button on its front panel.
This completes the software/hardware Installation. Next, read carefully the safety features
(section 2.3 of ECP Model 730 Manual). Finally, go to chapter 3 for a Self-geided demo:
ECP Mode! 730 Installation Instructions ~ Windows 7 6abit 3