Uses Dosage
n To improve the effectiveness of the water content of a The optimum dosage of Conplast RP264 to meet specific
concrete mix. requirements should always be determined by trials using the
n To help maintain the workability of readymixed concrete materials and conditions that will be experienced in use. The
deliveries in hot weather. normal dosage range is 0.3 to 0.8 litres/100 kg of cementitious
material, including PFA, GGBFS or microsilica.
n To extend working times of concrete.
n Particularly suitable for use in mixes with low cohesion. Use at other dosages
Conplast RP264 is compatible with other Fosroc admixtures Conplast RP264 has a minimum shelf life of 12 months
used in the same concrete mix. All admixtures should be provided the temperature is kept within the range of 2°C to
added to the concrete separately and must not be mixed 50°C. Should the temperature of the product fall outside this
together prior to addition. The resultant properties of concrete range then contact Fosroc for advice.
containing more than one admixture should be assessed by
Freezing point: Approximately -4°C
trial mixes.
Conplast RP264 is suitable for use with all types of Portland Precautions
cements, SRC cements and cement replacement materials
Health and safety
such as PFA, GGBFS and microsilica.
Conplast RP264 does not fall into the hazard classifications
Dispensing
of current regulations. However, it should not be swallowed
The correct quantity of Conplast RP264 should be measured or allowed to come into contact with skin and eyes.
by means of a recommended dispenser. The admixture should
Suitable protective gloves and goggles should be worn.
then be added to the concrete with the mixing water to obtain
the best results. Contact Fosroc for advice regarding suitable Splashes on the skin should be removed with water. In case
equipment and its installation. of contact with eyes rinse immediately with plenty of water
and seek medical advice. If swallowed seek medical attention
Effects of overdosing
immediately - do not induce vomiting.
An overdose of double the intended amount of Conplast
For further information consult the Material Safety Data Sheet
RP264 will result in a significant increase in retardation as
available for this product.
compared to that normally obtained at the intended dosage.
Provided that adequate curing is maintained, the ultimate Fire
strength of the concrete will not be impaired by increased
Conplast RP264 is water based and non-flammable.
retardation and will generally be increased. The effects of
overdosing will be further increased if sulphate resisting Cleaning and disposal
cement or cement replacement materials are used.
Spillages of Conplast RP264 should be absorbed onto sand,
earth or vermiculite and transferred to suitable containers.
Estimating - packaging
Remnants should be hosed down with large quantities of
Conplast RP264 is available in 210 litre drums and bulk supply. water.
For larger users, storage tanks can be supplied.
The disposal of excess or waste material should be carried
out in accordance with local legislation under the guidance
of the local waste regulatory authority.
Important note
Fosroc products are guaranteed against defective materials and manufacture and are sold subject to its standard terms and conditions of sale, copies of
which may be obtained on request. Whilst Fosroc endeavours to ensure that the technical information on this data sheet is correct at the time of printing,
it is the customers responsibility to satisfy himself, by checking with the company that this information is still current at the time of use, that the product is
suitable for the intended application, and that the actual conditions of use are in accordance with those recommended. Because Fosroc has no control over
the conditions of use of its products, all recommendations or suggestions regarding the use of these products are made without guarantee.
UAE/0004/01/I
www.fosrocgulf.com