Вы находитесь на странице: 1из 4

DuPont™ Vespel® CR-6100

Project Report for Non-metallic wear parts of BFW


Pump

Installation of Vespel CR-6100 Non-metallic Wear


rings on BFW pump at Hindalco-Renukoot.

 Pump make: KSB, Pune

 Model: KSB HDA 100/8

 Pump Sr No:819002

 Item No:M2202041181 & M2202041191

Supplier
 M/s Mascot Dynamics Pvt Ltd.

User
 Hindalco Industries Ltd, Renukoot
30 MW x 2 Power Plant.
MASCOT DYNAMICS PVT. LTD.
Add.: Plot No. W‐89 & 90, MIDC Indl. Area, 
Add. Ambernath (E), Maharashtra ‐ 421506. INDIA
Tel.: +91 251 2620601/02        Fax: +91 251 2620604
E‐mail: sales@mascotdynamics.com
Website: www.mascotdynamics.com
POWER SAVING CALCULATIONS
Pump Make : KSB HDA100/8 Customer: Hindalco Renukoot
Parameters Unit Existing Specs as per data sheet  Improved Projected Specs with Vespel wear parts
Capacity m3/hr 108.9 108.9
Head per stage (total head 800 m with 8 stages) m 100 100
Speed rpm 2980 2980
Specific Gravity 0.981 0.981
Efficiency % 76 79.04
Bkw kW 306.41 294.63
Difference (Power Saving) kW 11.78
Per Year No of Hours Hrs. 8760.00
Total Unit Power Saving kW‐Hr 103211.15
Power Cost per Unit Rs./kW‐Hr 3.00
Total Power Cost Reduced Per Year Rs. 309633.45

Note : Trimming of the impeller is required to reduce the increased head and realise the total power saving.

Prepared by Checked by
Avdhut Kunte Mr. Pradeep Dhole
(avdhut.kunte@mascotdynamics.com) (pradeep.dhole@mascotdynamics.com)
T
dyn ami cs

**Comparison of results before and after installation of Vespel

Actual Result comparison

The readings recorded before pump shut-off with metallic wear rings.

• Flow= 88 m3/hr.
• Discharge Pressure= 84 kg/ cm2g
• Suction Pressure= 1.7 kg I cm2g
• Sp.Gravity of liquid= 0.981

Hence differential head is,

(84- 1. 7} x 10 =838.94 M.tr


0.981

Power in kW = {88 x 838.94 x 0.981)

367 X 0.76

= 259.6 Kw

Current measured by Energy meter before Installation of Vespel = 66 amps

Power per 1 amp= 259.6 = 3.93 kW

66

Current measured by Energy meter after installation of Vespel = 62.5 amps

Hence Power reduction corresponding to 3.5 amps =13.76 kW

Saving in Energy /kw-hr = 13.76 x 3 = Rs 41.265/-

Cost of power saving per year= 41.265 x 8760 = Rs. 3,61,481/-

MASCOT DYNAMICS PVT. LTD.


CIN No . U29199MH2011PTC221875
Registered Office· Gangotri Glacier Annex, Kavesar, Opp. Vijay Nagri, Off. Ghodbunder Road , Thane (W) · 400 607. India
Tel. : + 91 22 2597 6464 I 65. Fai<· +91 22 2597 6466. E-mail: sales@mascotdynamics.com Website : www.mascotdynamlcs.com
Factory Address · Plot No. W - 89 & 90, MIDC lndl . Area . Add . Ambernath (E), Maharashtra - 421506. Tel. : -r 91 251 2620601 / 02
sales serv1ce support
T
dynam1cs

Customer : Hindalco Industries Ltd


,Renukoot
Pump Make : KSB
Pump Model no :HDAl00/8

PARAMETERS

Parameters Pump with Metal wear ring Pump with Vespel CR-6100 wear ring
Discharge flow 88 ton/hr. 90 ton/hr.
Current 66 ampere 62.5 ampere
Inlet pressure 1. 7 Ko/cm2 1.5 ko/cm2
Outlet pressure 84 kq/cm2 78 ka/cm2
Plant load 30 MW 30 MW
Temp 60 deg . Celsius 55 deg.celsius

Observed parameter before and after installation of Vespel from control room and current measured
Energy meter at Hindalco Renukoot Plant.

Committed power saving as per analysis of data sheet and performance curve was-4 °/o (11.78kW)

Saving achieved:-4.7 Ofo (13.76 Kw)

MASCOT DYNAMICS PVT. LTD.


CIN No . U29199MH2011 PTC221875
Registered Office: Gangotri Glacier Annex, Kavesar, Opp. Vijay Nagri , Off. Ghodbunder Road , Thane (W) - 400 607. India
Tel. : +91 22 2597 6464/65. Fax: +91 22 2597 6466. E-mail : sales@mascotdynamics.com Website: www.mascotdynamics.com
Factory Address · Plot No W- 89 & 90, MIDC lndl. Area, Add . Ambernath (E) , Maharashtra - 421506. Tel. : +91 251 2620601 / 02
sales serv1ce support