MasterProtect® 1815

A non-toxic, flexible high build, epoxy polysulfide coating

DESCRIPTION TYPICAL PROPERTIES


MasterProtect 1815 is a protective flexible high
build epoxy polysulfide resin coating specifically Volume Solids 100%
developed to protect concrete and steel from Mixed Density at 25°C 1.286 kg/l
contact with aggressive chemicals, oils, mild Pot Life at 25°C 45 min
acids, solvents and has a broad spectrum of Tack free time at 25°C 6 hours
chemical resistance. Supplied as a two-pack Full cure at 25°C 7 days
system, comprising pigmented base and a Inter-coat time at 25°C 9 hours
Tensile strength at 7 days 24 MPa
hardener, it requires only on site mixing to
ASTM D638
produce an easily applied decorative and
Elongation at 7 days 4%
chemically resistant finish. ASTM D638
Hardness (Shore D) 82
PRIMARY USES ASTM D2240
For the internal protection of concrete or metal U/V resistant (500h Xenon Arc) Resistant
tanks containing sewage, sludge, certain ASTM G53-58
chemicals, oils and fuel. Contact your BASF Adhesion to steel Excellent
Adhesion to concrete Concrete failure
representative for further advice.
Rapid Chloride Permeability Nil
As an impervious, resilient and chemically ASTM C1202
resistant floor or wall coating and as a gas and Water Permeability DIN 1048 Nil
vapour barrier.
As a protective and decorative coating in
APPLICATION PROCEDURE
laboratories, abattoirs, etc. Other usage areas
include oil refineries, paper mills, power stations,
marine applications, garages, hospitals, hangars SURFACE PREPARATION
and most liquid containment areas. Surfaces must be clean and dry. Use suitable
methods to remove dirt, dust, oil and all other
APPEARANCE AND FINISH forms of contamination that could interface with
High gloss, heavy bodied, ultra dense surface. the adhesion of the coating.
Hygienic and easily cleaned. Standard colours are
silver grey and window grey. CONCRETE
Concrete must be cured for 28 days. Mechanically
ADVANTAGES surface profile the substrate to CSP3 as described
 Superior chemical resistance by the International Concrete Repair Institute.
 Waterproof and protective Voids and pinholes must be repaired with suitable
products from the MasterBrace range. Porous
 Durable
concrete should be primed with
 UV resistant
MasterProtect P 659.
 Easily applied by brush or roller
 Flexible
STEEL
 Tough
Prepare to SSPC-SP6. Surface profile 50-75
micron. Do not allow surface to re-oxide before
PACKAGING
application of MasterProtect 1815.
MasterProtect 1815 is supplied in 10 litre units.
MasterProtect® 1815

MIXING CHEMICAL RESISTANCE


MasterProtect 1815 is supplied in two pre- MasterProtect 1815 is resistant to the following
weighed components, base and reactor. No typically encountered chemicals:
additions or omissions are required. Add reactor  Chlorine Water – 50ppm
contents to the base component and mix  Deionised Water
thoroughly for at least 3 minutes using a slow  Gasoline
speed drill fitted with a suitable mixing paddle until  Diesel fuel
a uniform streak free colour is achieved.  Phosphoric Acid 20%
 Vegetable Oil
APPLICATION  Sodium Chloride Saturated
MasterProtect 1815 coating can be applied using  Hydrochloric Acid 5%
good quality rollers or short haired brushes or by  Sulfuric Acid 10%
airless spray. MasterProtect 1815 should be  Calcium Hydroxide Saturated
applied in two coats of contrasting colours to  Isopropanol
ensure complete coverage.  Sodium Hydroxide 50%
If the application is delayed more than 16 hours at
 Nitric Acid 20%
40°C or 36 hours at 20°C after the previous coat
 Acetic Acid 10%
(the higher the ambient temperature, the shorter
the maximum period), then the previous coat must  Lactic Acid 10%
be thoroughly abraded to give an adequate  Ammonium Hydroxide 30%
mechanical key and solvent wiped.  Formaldehyde 37%

APPLICATION TEMPERATURE EQUIPMENT CARE


The quality of the final coating is dependent on the All equipment must be cleaned immediately after
substrate and the material temperatures. A use with MasterTop THN 2. Similar cleaning
substrate temperature of min. +14°C and max. procedures should be adopted for break periods
+30°C is required. Prior to application the optimal exceeding 15 minutes duration.
material temperature is +20°C to +25°C.
SPECIFICATION CLAUSE
AIRLESS SPRAY Where indicated, apply MasterProtect 1815
For application by airless spray, use a 45:1 or protective epoxy polysulfide coating as
higher ratio pump, minimum 9mm dia. hoses and manufactured by BASF, or similar approved to the
HD tip 19-23 thou. following specification:
Composition: Two component, non-toxic,
OVERCOATING pigmented epoxy polysulfide
resin based compound.
Where areas need to be overcoated due to Coverage: Two coats at 0.25L/m²/coat.
damage etc. it is important that the areas to be Dry film thickness: 500 microns
treated are well abraded using a stiff rotary wire
brush or coarse sand paper to give an adequate
key. Completely strip off any unsound coating and
proceed with overcoating as for new work.
MasterProtect® 1815

STORAGE NOTE
Store under cover out of direct sunlight and Field service, where provided, does not constitute
protect from extremes of temperature. In tropical supervisory responsibility. For additional
climates the product must be stored in an air information contact your local BASF
conditioned environment. Failure to comply with representative.
the recommended storage conditions may result
in premature deterioration of the product or BASF reserves the right to have the true cause of
packaging. For specific storage advice, consult any difficulty determined by accepted test
BASF's Technical Services Department. methods.

SAFETY PRECAUTIONS QUALITY AND CARE


As with all chemical products, care should be All products originating from BASF facility are
taken during use and storage to avoid contact with manufactured under a management system
eyes mouth, skin and foodstuffs. Treat splashes to independently certified to conform to the
eyes and skin immediately. If accidentally requirements of the quality, environmental and
ingested, seek immediate medical attention. Keep occupational health and safety standards of ISO
away from children & animals. Reseal containers 9001, ISO 14001 and OHSAS 18001.
after use. For further information, refer to material
safety data sheet.
* Properties listed are based on laboratory controlled tests.

® = Registered trademark of the BASF-Group in many countries.

BASF_CC-UAE/Pr_1815_09_10/v3/01_17
The technical information and application advice given in this BASF publication are based on the present state of
STATEMENT OF our best scientific and practical knowledge. As the information herein is of a general nature, no assumption can be
RESPONSIBILITY made as to a product's suitability for a particular use or application and no warranty as to its accuracy, reliability or
completeness either expressed or implied is given other than those required by law. The user is responsible for
checking the suitability of products for their intended use.

Field service where provided does not constitute supervisory responsibility. Suggestions made by BASF either
NOTE orally or in writing may be followed, modified or rejected by the owner, engineer or contractor since they, and not
BASF, are responsible for carrying out procedures appropriate to a specific application.

BASF Construction Chemicals UAE LLC


Disclaimer: the LRQA mark relates
P.O. Box 37127, Dubai, UAE to certified management system and
Tel: +971 4 8090800, Fax: +971 4 8851002 not to the product mentioned on this
www.master-builders-solutions.basf.ae datasheet