Regla heurística
Preceder con un enfriador usando un refrigerante
1A mas caliente en el rango TL<TR<(TL-1-20°F)
S12 S13 V1-OUT VALV189
Regla heurística
Seleccionar el siguiente elemento con mayor
2A
-(DB)
S12 S13 S14 V1-OUT VALV189
Temperature F 70 70 -105
Pressure psia 800 800 796
Vapor Frac 1 1 1
Mole Flow lbmol/hr 103.889 154.281 154.281
Mass Flow lb/hr 1666.667 2475.089 2475.089
Volume Flow cuft/hr 653.51 970.497 262.052
Enthalpy MMBtu/hr -3.381 -5.02 -5.42
Mole Flow lbmol/hr
METHANE 103.889 154.281 154.281
AVAIL Btu/lbmol
METHANE -17570.494 -17570.494 -16818.212
AVAIL Btu/hr
METHANE -1.83E+06 -2.71E+06 -2.59E+06
-DB
Equipo Btu/hr CF (USD/y)
Heater-1 -9.70E+03 CV (USD/y)
Heater-2 7.15E+04 CT (USD/y)
Heater-3 -2.69E+04
Heater-4 -1.32E+05
Heater-5 -1.57E+04
Heater-6 -2.08E+04
Compresor
Heater-7 -6.99E+04
HE 10 4.89E+03
HE 20 -3.81E+05
COMP-1 -2.58E+05
COMP-2 -3.52E+04
FLASH1 3.00E+01
FLASH2 1.00E+02
Regla heurística
Un compresos adicional y un enfriador intermedio (estado
de compresión)
Compresor 4A y 4B Seleccionar el siguiente elemento con mayor
-(DB)
Installed Weight
[LBS]
7001
0
22165
18277
16072
6832
0
9751
9322
5421
0
5421
7700
12404
28504
0
8602
S012 S013 S13 S14 S15 S16 S17 S18
Temperature F 70 70 -105
Pressure psia 800 800 796
Vapor Frac 1 1 1
Mole Flow lbmol/hr 103.889 154.285 154.285
Mass Flow lb/hr 1666.667 2475.151 2475.151
Volume Flow cuft/hr 653.51 970.521 262.059
Enthalpy MMBtu/hr -3.381 -5.02 -5.42
Mole Flow lbmol/hr
METHANE 103.889 154.285 154.285
AVAIL Btu/lbmol
METHANE -17570.494 -17570.494 -16818.212
AVAIL Btu/hr
METHANE -1.83E+06 -2.71E+06 -2.59E+06
-DB
Equipo Btu/hr CF (USD/y)
Heater-1 -9.70E+03 CV (USD/y)
Heater-2 2.99E+04 CT (USD/y)
Heater-3 1.37E+03
Heater-4 -1.32E+05
Heater-5 -1.58E+04
Válvula de expansión Joule-
Heater-6 -2.08E+04 Thompson
Heater-7 -6.98E+04
HE 10 4.89E+03
HE 20 3.19E+04
COMP-1 -9.15E+04
COMP-2 -3.54E+04
COMP-3 -1.29E+05
FLASH1 -3.00E+01
FLASH2 1.00E+02
Regla heurística
Una válvula de expansión Joule-Thompson adicional,
Válvula de expansión Joule- 3A tomando como entrada L y expidiéndola a una presión
Thompson intermedia
Installed Weight
[LBS]
16072
25411
7440
12404
5421
0
8602
7700
7001
6505
0
22165
0
18277
9751
5421
0
25529
9322
S11 S12 S13 S14 S15 S16 S17 S18