Вы находитесь на странице: 1из 1

NICKEL METAL HYDRIDE BATTERIES: INDIVIDUAL DATA SHEET

HHR370AH Cylindrical L-Fat A size (HR 18/67) Typical Charge Characteristics


Dimensions (with Tube) (mm) 2.0
Charge: 330mA(0.1 It)✕16hrs.
1.9
1.8
1.7
1.6

Voltage (V)
1.5
1.4
1.3
1.2
18.2 +- 00.7 1.1
1.0 -10˚C
(+) 25˚C
0.9 60˚C
0.8
0 2 4 6 8 10 12 14 16 18 20
Charge Time (hours)

Typical Discharge Characteristics


67.0 +- 01.5

120
110
100

Capacity Ratio (%)


90
80
70
60
( ) 50 Charge: 330mA(0.1 It)✕15hrs
Disharge: 660mA(0.2 It),cut off voltage 1.0V
40
Specifications 30
Disharge Temperature: 20˚C

mm inch - 20 - 10 0 10 20 30 40 50 60 70
Temperature (˚C)
Diameter 18.2+0/-0.7 0.72+0/-0.03
Height 67.0+0/-1.5 2.64+0/-0.06
Approximate Grams Ounces
Weight 60 2.12
2.0
Nominal Voltage 1.2V Charge: 330mA(0.1 It)✕16hrs,25˚C
1.9
Discharge Average2 3700 mAh Disharge: 660mA(0.2 It)
1.8
Capacity1 Rated (Min.) 3500 mAh 1.7
Approx. Internal impedance 1.6
20mΩ
Voltage (V)

at 1000Hz at charged state. 1.5


Standard 370mA x 16hrs. 1.4
Charge Rapid3 1750mA x 2.4 hrs.4 1.3
185mA x 32 hrs. 1.2
Low Rate
123mA x 48 hrs. 1.1
0˚C
Standard ˚C ˚F 1.0
25˚C
Charge -10˚C to 60˚C 14˚F to 140˚F 0.9
Temperature

60˚C
Rapid -10˚C to 45˚C 14˚F to 113˚F 0.8
Ambient

0 1 2 3 4 5 6
Discharge -10˚C to 60˚C 14˚F to 140˚F
Charge Time (hours)
< 1 year -20˚C to 35˚C -4˚F to 95˚F
< 6 months -20˚C to 45˚C -4˚F to 113˚F
Storage
< 1 month -20˚C to 55˚C -4˚F to 131˚F
< 1 week -20˚C to 65˚C -4˚F to 149˚F
1 After charging at 0.1It for 16 hours, discharging at 0.2It.
2 For reference only.
3 Need specially designed control system
Control System:
dT/dt cut-off; 1 to 2°C/min
-UV cut-off; -UV per cell = 5 to 10 mV
T-control; T=65°C
Rapid charger timer; 2.4h (at 1.25a)
Trickle timer; within 2h Note: [It] was previously expressed as [C]. [It] is an IEC standard expression
4 With control system for the amount of charge or discharge current and is expressed as:
It(A) = Cn (Ah)/1h.
Battery performance and cycle life are strongly affected by how they • [It] is the reference test current in ampres
are used. In order to maximize battery safety, please consult Panasonic • [Cn] is the rated capacity of the cell or battery in Ampere-hours.
when determining charge / discharge specs, warning label contents and n = the time base [hours] for which the rated capacity is declared
unit design.

NICKEL METAL HYDRIDE HANDBOOK AUGUST 2003


This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to
modification without notice. Contact Panasonic for the latest information.