Вы находитесь на странице: 1из 1

DYWIDAG Flat Multiplane Anchorage

Technical Data
Actual concrete strength at stressing: 25 N/mm² (cube) or 20 N/mm² (cylinder)
type no. of ultimate load min. center min. slab Anchor Body additional reinforcement (stirrups) Duct
0.5'' strands distance thickness 1) A B axb n Ø I.D.
Ø 12.7 mm fpk =1860 N/mm² mm mm mm mm mm

59 03 3 558 kN 200 200 160 160 180 x 140 3 12 19 x 43

59 05 5 930 kN 320 200 203 228 230 x 140 3 12 70 x 20

type no. of ultimate load min. center min. slab Anchor Body additional reinforcement (stirrups) Duct
0.60" strands distance thickness 1) A B axb n Ø I.D.
Ø 15.3 mm fpk =1860
1860 N/mm
N/mm² mm mm mm mm mm

68 02 2 521 kN 200 200 160 160 160 x 140 3 12 19 x 43

68 04 4 1042 kN 300 220 203 228 230 x 160 4 12 70 x 20

68 05 5 1302 kN 380 220 268 231 300 x 160 4 12 90 x 20

type no. of ultimate load min. center min. slab Anchor Body additional reinforcement (stirrups) Duct
0.62" strands distance thickness 1) A B axb n Ø I.D.
Ø 15.7 mm fpk =1860 N/mm² mm mm mm mm mm

68 04 4 1116 kN 320 220 203 228 230 x 160 4 12 70 x 20

68 05 5 1395 kN 400 220 268 231 310 x 160 4 12 90 x 20

Anchor Body with additional reinforcement (here: 1 stirrup)

1) assumed: concrete cover: 30 mm

* min.
i slab
l b thi
thickness
k can b
be reduced
d d tto 200 mm ffor hi
higher
h concrete
t strength
t th

DYWIDAG-Systems International GmbH Phone: +49-89-309050-100

Siemensstr. 8 Fax: +49-89-309050-120

85716 Unterschleissheim E-mail:dsihv@dywidag-systems.com

Germany www.dywidag-systems.com Subject to modification, March 2009