TRAINING REPORT ON
“RFM
DIVISION”
3
CONTENTS
1. INTRODUCTION………………………………………………………….1.
2. WHAT IS RFM?....................................................................................5.
3 SPECIFICATIONS………………………………………………………...6
5. DISCRIPTION OF COMPONENTS……………………………………..9-31
4
INTRODUCTION
This division is the manufacturer of switchgear. Now its name is changed to SCR
division. This division contains eight bays. For each bay two overhead cranes are
manufactured for loading of jobs. Capacity of each crane is ten tones maximum.
This section has the following division;-
5. Tap Changer
6. T C Assembly
5
First of all a question arises, why protection is
needed?
Power systems of our country as well as of other country are growing faster
with more & more electrical appliances. A high degree of reliability is required
for system operation. So we have to protect the system from faults like
overloads, under voltage, over voltage etc. For protection, we use protective
devices, which are reliable such as relays circuit breakers etc. Sometimes for
the maintenance of the system, we want to break the circuit. So we use switches
for making & breaking of the circuit.
6
RECTIFIER MANUFACTURING DIVISION
Guided by Shri A K Bhargava (Mgr.)
RFM DEPARTMENT
1.Rectifiers
2.Inverters
3.Electronic precipitators
5.E-Type
RECTIFIERS (AMR)
7
SPECIFICATIONS
2. DC volts 1200
3. DC AMPS 3800
6. Primary phases 3
8. Connections Bridge
TYPES OF RECTIFIER:-
8
ELECTRONIC MANUFACTURING DEPARTMENT(ELM)
9
DESCRIPTION OF COMPONENTS
10
STATIC VOLTAGE REGULATOR TYPE E-301
The panel consists of two plug in cards power card (BX) & control card
(BN),an externally potentiometer, Fuse, Capacitor, Inductor& Rely
PCB.
The power card supplies power to the Gate pulse of SCR-1, SCR-2,
SCR-3 after comparing the sample of generator output with suitable
reference. A signal proportional To load current feed to current limiting
circuit if current across the set limit it will brings Down the output
voltage of the generator by controlling the transistor.
Auxiliary generator field which control & regulate the generator output.
The control Card varies the output of the power card by controlling
the firing pulse of the Thirstier.
The whole electronic circuitry is laid on 7 plugs in type cards which plug in
receptacles carries the necessary internal wiring. For external wiring connection.
11
A terminal board is mounted on the lower adage of panel. Each card each slot
On the panel is numbered for easy identification & reference.
12
BLOCK DIAGRAM
13
C U R R E N T
M E A S U R E
BATTERY BIAS
B + 7 2 V
T E C H O
REFERENCE
FEEDBACK
G E N
BATTERY
A G S P E E D S I G N A L
VRP
MASURMENT
D I E S E L
E N G I N E
ENGINE
B - 7 2 V
SPEED
BIAS REF
CURRENT
TX-Motor
GENERATOR
SUICIDE
FUNCTION
T G
& STAB
MEASURE
VOLTAGE
E X
OSCILLATOR
MIXER REF
CARE 186
400HZ SQ
CARD
P W M
C O N T R O L S I G N A L
C A R D
V O L T A G E F E E D B A C K
B L O C K D I A G R A M E - T Y P E E X C I T A T I O N S Y S T E
14
DESCRIPTION OF CARDS
15
THE DESCRIPTION OF CARDS:-
called pulse width modulation card. It is the double card like oscillator
card. Left hand side card is for braking stabilization. The right hand
side card is for magnetic amplification & for exciter stabilization.
16
5. POWER TRANSITION CARD:- Card in fifth slot is called power
function generator card. It is a also double card. Left hand side card
contain the electrical horse power limit circuit that provide a
relationship between main generator voltage & current in the DC
control winding of current measuring reactor ACCR. The function
generator card also provide circuit for reducing the electrical HP
demands to match diesel engine capability at lower engine seed as
determine by intermediate notches.
17
ENGINE CONTROL PANEL TYPE E-
306
The auxiliary panel is electronics component common to the entire card. The engine
Control panel contains devices which regulator, rectify & adjust a.c. speed signal from
an governor stabilization & speed circuit. An engine speed –sensing transformer
(ESST) Located in the left of ECP panel receives frequency signal of three-phase a.c.
Techogenerator. This saturating transformer has secondary windings connected to 3-
phase, full wave bridge rectifiers .The rectified out put of each secondary function
separately as follows.
Control the engine speed through engine Governor. Provides a
reference signal to control instantaneous Values of traction voltage & current feed
signal to function generator module to control the horsepower limits.
# Eleven capacitors are located in the panel n. A set of six CCI capacitors all
Connected in parallel is used as.
18
TRANSITION CONTROL PANEL TYPE E-307
Transistor control panel is used to initiate transition events, i.e. field
weakening & regrouping of function motors. It acts & a speed signal received
from axial generator through transition excitation transformer. The panel is steel
fabricated housing, which contains four plugs in card numbered As 207,210,a small
auxiliary panel & choke mounted on a frame. Three210 cards inserted are identical
except for the setting of potentiometer P1& P2 mounted on the card . Each Card
contains a transistor circuit to switch on a relay mounted on it & control one transistor
event. Card 207 contain a rectifier bridge circuit for conversion.
19
Fig3.transition control panel.
Ratings:-
Current: 12 Amps
Reverse voltage: 72 Volts
Type:- 308
Range:-
For 1200 HP to 3600 HP Diesel
Electric locomotive
20
Fig4. Inverse voltage suppression panel
21
Braking Limit Voltage Divider:- It is a
frequency modulated device. It contains saturable core transformer
encapsulated in epoxy. The secondry voltage depends upon the
frequency of primary input signal, but is independent of the amplifier of
the input signal.
Ratings:-
Type:- 323
Range:-
22
Armature Current Control Reactor
Ratings
DC current: 4500 Amp
Type311
Range
For 1200 HP to 3600 HP Diesel
Electric locomotives
Applications
Armature Current Control Reactor (ACCR) is an magnetic reactor used for
sensing of alternator/ Generator current
23
Stabilizing panel for AC-DC system
Ratings
Meets time delay and
Stabilization requirement of E type
Excitation controls of Loco.
Type309,309A
Range
For 1200 HP to 3600 HP Diesel
Electric locomotives
Applications
Provides time delay and stabilisation in control circuit of excitation.
24
Reverse current diode panel
Ratings
DC current: 200 Amp
Blocking voltage: 72 volts
Type305
Range
For 1200 HP to 3600 HP Diesel
Electric locomotives
Applications
Blocks discharge of battery into the Auxiliary Generator during failure of
charging circuit or/and not running of engine.
25
Field Control Panel
Ratings:
Power Rating: 4X250 watts
Suitability: For AG51,
AG2702, AG 3101
Range
For 1200 HP to 3600 HP Diesel
Electric locomotives
Applications:
Current limit and Voltage biasing of exciter field
26
Generator Voltage Divider Panel
Ratings:
Power : 4x 100 watts
Voltage: 1200 Volts
Type
319,319A,319B
Range
For 1200 HP to 3600 HP Diesel
Electric locomotives
Applications:
Voltage sensing of Rectifier/generator output
27
Load Control Panel
Ratings
Power : 2x 140 watts
Suitable: GE & WW
Governors
Type
329,329A,329B
Range
For 1200 HP to 3600 HP Diesel
Electric locomotives
Applications:
Provide biasing voltage for governor feedback potentiometer
28
Load limit resistor
Ratings
Power : 3x 25 watts
Type
324A
Range
For 1200 HP to 3600 HP Diesel
Electric locomotives
Applications:
Provides current limit wheel slip circuit
29
30