IV-H Series
SIEMENS
S7-1500 Series
PLEASE PREPARE
Please prepare the following products.
SIEMENS
S7-1500 Series
CONNECTING
Below would be the way how to connect the IV-H series to your PLC.
SIEMENS
S7-1500 Series
Ethernet cable
OP-87457
Signal Color
24V Brown
24VDV Power supply
0V Blue
2
SETTINGS [IV-H Series]
Use IV-Navigator for settings.
Use the Ethernet cable OP-87457 to connect Select “Advanced” " “Environmental”, and confirm
1 IV to your PC 4 what the “Device Name” is set to.
2 Start IV-Navigator
Select “Advanced” " “Environmental” " “Field
Double click the icon of IV-Navigator 5 Network”, and set the “Protocol” to “PROFINET”
on your desktop.
3
BASIC SETTINGS [SIEMENS S7-1500 SERIES]
TIA Portal V.13 or later would be required to communicate PROFINET.
Double click the icon of TIA Portal On the “Add new device” screen, click the S7-1500 Series you
on your desktop. are using, and then click “OK”.
4
BASIC SETTINGS [SIEMENS S7-1500 SERIES]
Click “Assign IP address” which is under “Functions”, Click “Project View” which is in the lower left of the
6 set the IP address and the subnet mask of 8 screen, and then click “Open” on the “Project” menu.
the S7-1500, and then click “Assign IP address”.
If the PLC already has one IP address set, you may not be Select a project, and then
able to set a new IP address. click “Open”.
At this case, click “Reset to factory settings”, and initialize the The “Open existing
IP address once. project” screen would be
displayed, click a project
and then click “Open”.
Double click “Devices &
networks”.
Specify the folder which has the GSDML file inside, select the
check box of the target GSDML file, and click “Install”.
5
BASIC SETTINGS [SIEMENS S7-1500 SERIES]
In the “Devices & networks” field, click the “Network Double click the image of IV-H, click the “General” tab,
10 view” tab, and drag “IV-HG Main Unit” to this tab. 13 click “PROFINET interface”, click “Ethernet
addresses”, and then set the IP address of IV-H.
Please drag the correct IV series you are using.
If the IP address which is already set to IV-H was different
from the one which you set here, the IP address would be
overwritten to this.
6
BASIC SETTINGS [SIEMENS S7-1500 SERIES]
Click the “Network view” tab, right click the image of On the “Extended download to device” screen, select
15 the PLC, point to “Compile”, and then click “Hardware 17 the interface connected to the PLC, select the target
and software (only changes)”. PLC, and then click “Load”.
7
MONITORING THE RESULT
1 Check the address of the PLC device assigned to IV-H 3 Switch to online mode and start monitoring.
On the “Network view” tab, click IV-H, and click the “Device Click “Go online” to switch to online mode.
view” tab.
The addresses are assigned to each module automatically. You could see the result in the “Monitor value”.
(These could be assigned manually also)
8
www.keyence.com
Copyright (c) 2017 KEYENCE CORPORATION. All rights reserved. IVHS7-1500ConnectionG-WW-TG-GB 1047-1 600M85