Академический Документы
Профессиональный Документы
Культура Документы
FG-42869 NORTH-WE-1
NORTH-WE-1STRUCTURE
DRAWING LIST
VARIES
19550.000
NORTH-WE-2 (SHEET 4 OF 4) 5. SHEATHING SHALL BE ACCURATELY POSITIONED AND TIED
ONTO THE REINFORCEMENT CAGE AT THE SPECIFIED
POST TENSIONING DETAILS LOCATIONS. ADDITIONAL INTERMEDIATE TENDON SUPPORT
FG-42869-PTSD-S01-003 HORIZONTAL TENDON PROFILES - WEB TENDONS BARS SHALL BE ADDED IF FOUND NECESSARY.
(SHEET 1 OF 6) 6. MAXIMUM SPACING OF SUPPORT BARS (CHAIRS) IS 1000mm.
7. WHENEVER THERE IS A CONFLICT BETWEEN A CABLE AND
C/L PIER 1
C/L PIER 2
POST TENSIONING DETAILS
C/L ABUT 1
C/L PIER 3
30000 FG-42869-PTSD-S01-003a HORIZONTAL TENDON PROFILES - WEB TENDONS PROFILE SHALL GOVERN.
NAVIGATION CHANNEL 8. BURSTING REINFORCEMENT SHALL BE INSTALLED AT
(SHEET 2 OF 6) BOTH ENDS.
8000 POST TENSIONING DETAILS 9. THE APPLICATION OF PRESTRESSING FORCE SHALL BE
APPROACH 70000mm 90000mm 70000mm APPLIED WHEN THE CONCRETE HAS ACHIEVED A MINIMUM
MEASURED ALONG FG-42869-PTSD-S01-003b HORIZONTAL TENDON PROFILES - WEB TENDONS CYLINDER COMPRESSIVE STRENGTH OF 30 MPa.
SLAB SPAN 1 SPAN 2 SPAN 3 C/L OF BRIDGE
(SHEET 3 OF 6) 10. ALL TENDONS TO BE STRESSED ACCORDING TO THE
REINFORCED SOIL WALL (TYP)
POST TENSIONING DETAILS HORIZONTAL TENDON STRESSING DETAILS GIVEN IN THIS SET OF DRAWINGS.
11. UPON COMPLETION OF STRESSING WORK, ALL TENDONS
FG-42869-PTSD-S01-003c PROFILES - BOTTOM SLAB TENDONS SHALL BE FULLY GROUTED WITH A GROUT OF A MINIMUM
(SHEET 4 OF 6) COMPRESSIVE CYLINDER STRENGTH OF 25 MPa AT 7 DAYS
AND 41.7 MPa AT 28 DAYS (COMPRESSIVE CUBE STRENGTH
POST TENSIONING DETAILS HORIZONTAL TENDON
GENERAL PLAN PROFILES - BOTTOM SLAB TENDONS
AT 7 DAYS 30 MPa, AT 28 DAYS 50 MPa).
12. AFTER COMPLETION OF STRESSING AND GROUTING TO THE
FG-42869-PTSD-S01-003d
SATISFACTION OF THE ENGINEER, THE CABLE ANCHORAGE
(SHEET 5 OF 6)
RECESSES SHALL BE FILLED WITH CONCRETE OF 28 DAYS
340mmØ
POST TENSIONING DETAILS HORIZONTAL TENDON COMPRESSIVE CYLINDER STRENGTH OF 37.5 MPa.
8 TURNS AT 60mm PITCH 430mmØ 2 7 TURNS AT 70mm PITCH 2
PROFILES - BOTTOM SLAB TENDONS 13. CROPPING AND GROUTING OF CABLES SHALL NOT BE
FG-42869-PTSD-S01-003e CARRIED OUT WITHOUT THE APPROVAL OF THE ENGINEER.
80 40 60mm (TYP.) (SHEET 6 OF 6)
70mm (TYP.)
65 40 POST TENSIONING DETAILS CROSS SECTIONS AND
T16 SPIRAL FG-42869-PTSD-S01-004
250 REF. SECTIONS FOR DIM Y & DIM Z (SHEET 1 OF 6)
200 T14 SPIRAL
POST TENSIONING DETAILS
FG-42869-PTSD-S01-004a
2 CROSS SECTIONS (SHEET 2 OF 6)
POST TENSIONING DETAILS DRAWING REFERENCES
FG-42869-PTSD-S01-004b
100mmØ O.D.
85mmØ O.D.
CROSS SECTIONS (SHEET 3 OF 6)
95mmØ I.D.
80mmØ I.D.
ST_BR_S01_04_01_001-C1, ST_BR_S01_04_02_001-C1,
300
240
185
150
POST TENSIONING DETAILS ST_BR_S01_04_02_002-C1, ST_BR_S01_04_02_004-C1,
FG-42869-PTSD-S01-004c
CROSS SECTIONS (SHEET 4 OF 6) ST_BR_S01_04_02_005-C1, ST_BR_S01_04_02_006-C1,
ST_BR_S01_04_02_016-C1, ST_BR_S01_04_02_017-C1,
POST TENSIONING DETAILS ST_BR_S01_04_02_019-C1, ST_BR_S01_04_02_020-C1,
FG-42869-PTSD-S01-004d ST_BR_S01_04_02_021-C1 & ST_BR_S01_04_02_022-C
CROSS SECTIONS (SHEET 5 OF 6)
19C15 ANCHOR DETAILS (WEB TENDONS) 12C15 ANCHOR DETAILS (BOT. SLAB TENDONS)
SCALE: 1 : 10 POST TENSIONING DETAILS
SCALE: 1 : 10 2 10.04.2018 REVISED AS MARKED
FG-42869-PTSD-S01-004e
CROSS SECTIONS (SHEET 6 OF 6) 1 23.01.2018 ISSUED FOR APPROVAL
0 23.11.2017 ISSUED FOR APPROVAL
VALVE POST TENSIONING DETAILS ANCHORS DETAILS - NO. DATE DESCRIPTION
L=300mm FG-42869-PTSD-S01-005
GROUT VENT PLASTIC SADDLE TO BE SECURED WEB TENDONS AT ABUTMENT 1 (SHEET 1 OF 6) Client
L/2 L/2 MIN. 300mm LONG GROUT VENT TUBE
TUBE BY GAUGE WIRE AND SEALED
DUCT COUPLER 1 INCH
WITH DUCT TAPE
POST TENSIONING DETAILS ANCHORS DETAILS -
FG-42869-PTSD-S01-005a 13/09/17 FIRST ISSUE
WEB TENDONS AT PEAR 3 (SHEET 2 OF 6)
PLASTIC SADDLE TO BE
SECURED BY GAUGE WIRE POST TENSIONING DETAILS ANCHORS DETAILS -
& SEALED WITH PVC TAPE
(TYP.) EDGES TO BE FG-42869-PTSD-S01-005b WEB TENDONS AT ABUTMENT 1 & PEAR 3
SEALED WITH Consultant
50 MIN. 50 MIN. DUCT TAPE (TYP.) TYP. CONN. DET BETWEEN (SHEET 3 OF 6)
DRAIN VENT
TYP. DUCT CONN. DETAIL SCALE: 1 : 10 BOTTOM SLAB TENDONS @SPAN 2 (SHEET 4 OF 6)
TUBE
SCALE: 1 : 10
VALVE POST TENSIONING DETAILS ANCHORS DETAILS -
FG-42869-PTSD-S01-005d Contractor
BOTTOM SLAB TENDONS @SPAN 2 (SHEET 5 OF 6)
TYP. CROSS SECTION FOR Ø100mm OD GALVANIZED P.T. POST TENSIONING DETAILS ANCHORS DETAILS -
DUCTS TO BE TIED TO THE FG-42869-PTSD-S01-005e
GROUT / DRAIN VENT BAR WITH STEEL WIRE BOTTOM SLAB TENDONS (SHEET 6 OF 6)
SCALE: 1 : 20
PT Sub-contractor