Вы находитесь на странице: 1из 13

Low Cost Coulometric Karl Fischer Titrator MKC-501N 4/9/18, 12)26 PM

Models | Meas.Principle
Low Cost Coulometric Karl Fischer
Titrator MKC-501N
Rugged design, easy operation, low cost: The
coulometric Karl Fischer Titrator MCK-501N is a
compact, cost-effective solution for highly accurate
water content determinations in products which contain
small amounts of water.

Convenient
The MKC-501N is equipped with a diaphragmless generator
electrode. For most samples this type of generator electrode
offers more convenience, as it requires less maintenance and
no catholyte.

Space saving
The titration vessel is located not beside but on top of the
(/files/1813/9530/0652/mkc- housing of the instrument.
501n_zoom.jpg)
Expandable
Direct transmission of sample weights from a balance,
documentation of the results with a printer, easy data
transmission to MS EXCEL, moisture determinations of
solids with an optional evaporator – built-in interfaces and a
wide range of accessories ensure that the MKC-501N can
grow right along with your requirements.

Straight forward user interface, no flashy gimmicks


With the MKC-501N you invest in reliable mechanics and
electronics without waisting money for gimmicks you don't
need.

Made to be tough
The MKC-501N provides accurate results even in harsh
environments and comes with 3 years warranty against
material defect or dysfunction.

Details

Virtually maintenance free


he MKC-501N coulometric Karl Fischer Titrator is equipped
with a generator cell without diaphragm. This type of
generator cell requires only one Karl Fischer reagent and

https://www.gpsil.co.uk/our-products/karl-fischer-titrators/mkc-501n/ Page 1 of 13
Low Cost Coulometric Karl Fischer Titrator MKC-501N 4/9/18, 12)26 PM

offers thus two substantial advantages compared to


conventional generator cells:

less reagent consumption.


less contamination - easier cleaning.

This diaphragmless generator electrode is suitable for a large


number of applications. For some special applications like
water determinations in aldehydes and ketones, extremely
low water contents or samples with a very low conductivity (/files/2813/9532/4045/mkc-
(like e.g. oils) a generator electrode with diaphragm is 510_titration_cell.png)
required. For this reason, the MKC-501 Karl Fischer Titrator
is available in two different versions, one with a generator
electrode with (MKC-501D) and one without diaphragm
(MKC-501N). Both models can be used with either type of
generator electrode. It is thus possible to equip your MKC-
501N titrator with a conventional generator electrode with
diaphragm in case there is a need for it in the future.

Smooth data transfer


The MKC-501N is equipped with the three interfaces
required for a seemless integration into the usual workflows
in routine quality control:

Printer – to print out results (containing all the relevant data


like date, time, sample name and size, operator name,
etc.), statistics and lists of system performance checks.
Balance – to directly transmit sample weights from an
analytical balance from various manufacturers (Mettler
(/files/6813/9143/3302/IDP-
Toledo, A&D, Shimadzu, Sartorius).
100_zoom.jpg)
PC – to transmit the results to a personal computer. With
the Soft CAP Data Capture software the results can
directly be stored in EXCEL workbooks or csv files.

Applications

Food and Beverage


Cooking fat Rapeseed oil
Olive oil Safflower oil
Peanut oil Soy bean oil

https://www.gpsil.co.uk/our-products/karl-fischer-titrators/mkc-501n/ Page 2 of 13
Low Cost Coulometric Karl Fischer Titrator MKC-501N 4/9/18, 12)26 PM

Chemicals / Petrochemicals
ABS (9) Glass fibers and powder Standards
Acenaphthene (24)
Aerosil (13) Glycerol ASTM D 1533-00
Aldehydes (2) Glycerol monostearate ASTM D 3401-97
Alizarin Grease (7) ASTM D 4928-11
Allocymol Guaethol ASTM E 1064-08
Allyl chloride Gypsum (13)
Amyl acetate Heptanol DIN 51777
Anisole Hexane EN ISO 12937:2002-03
Aviation gasoline (5) (6) Hexanetriol
Benzene (1) Hexanol ISO 10337
Benzil Hexylene glycol ISO 10338
Benzoin Hydraulic oil (3) ISO 10339
Benzophenone Hydrocarbons (1) ISO 10340
Benzyl alcohol Icosane ISO 10341
Benzyl bromide Insulating oil (3) ISO 10342
Benzyl chloride Iodoanisole
Remarks (1) ... (26)
Benzyl phenyl ketone Iodoethane
(/files/4413/9541/0330/karl-
Biodiesel Iodomethane
fischer-
Biphenyl Iodonaphthene
procedures_coulometric.jpg)
Bromodecane Isopropanol
Bromoform Kerosene (5) (6)
Bromohexadecane Ketones (2)
Bromoisobutyric acid Lubricating oil (7)
ester Mannitol
Bromotetradecane Melamine resin (9)
Butane (25) Methane (25)
Butane (25) Methanol
Butanol Methoxybenzene
Butyl acetate Methyl salicylate
Camphor Methylbutadiene
Caprolactam (10) Methylcyclohexane
Carbazinic acid methyl Methylenephenanthrene
ester Methylpentanediol
Carbon black (18) Methylpentanol
Carbon dioxide (25) Motor oil (7)
Carbon powder (18) Natural gas (25)
Carbon tetrachloride Nitrogen (25)
Cetyl alcohol Nitrophenol
Chloral Nonanol
Chlorobenzene Norbornadiene
Chloroform Nylon 6 / Nylon 66 (12)
Chlorooctane Octacosane
Chlorophenol Octane
Chlorotoluene Octanol
Coal powder and dust Oxygen (25)

https://www.gpsil.co.uk/our-products/karl-fischer-titrators/mkc-501n/ Page 3 of 13
Low Cost Coulometric Karl Fischer Titrator MKC-501N 4/9/18, 12)26 PM

(18) Pentane
Cresol Pentanediol
Crude oil (4) Petroleum
Cyclododecane Phenol
Cycloheptane Phenol-formaldehyde
Cyclohexane resins (13)
Cyclohexanol Phenoxyethanol
Cyclohexyl chloride Phenylpropanol
Decylcyclohexane Plastics (8)
Dibenzylideneacetone Polyacrylamide (13)
Dibromomethane Polyamide (12)
Dichlorobenzene Polycarbodiimide (14)
Dichloroethane Polycarbonate (15)
Dichloromethane Polyester (16)
Dichlorophenol Polyether (14)
Dichlorotetrafluoroacetone Polyethylene (13)
Dicyclopentadiene Polyethylene glycol
Didecyl ether Polyethylene
Diesel fuel (5) (6) terephthalate (17)
Diethyl ether Polyimide (9)
Diethyleneglycol diethyl Polyisobutylene (18)
ether Polymethylmethacrylate
Diethyleneglycol (19)
monomethyl ether Polyoxymethylene (9)
Difluorobenzene Polypropylene (20)
Diheptyl ether Polystyrene (11)
Diisopropyl ketone Polyurethane (19)
Dimethyl terephthalate Polyvinyl acetate (21)
Dimethylbutane Polyvinyl butyral (PVB)
Dimethylnaphthalene (14)
Dimethylpentanol Propane (25)
Dimethylstyrene Propane (25)
Dioxane Propanol
Dodecane (1) Propylene oxide (25)
Dodecanol Propylene oxide (25)
Epoxy resin (11) PTFE (22)
Ethanol (4) Rubber (22)
Ether Silicone oil (26)
Ethyl acetate Silicone rubber (22)
Ethyl acetoacetate Soft PVC (15)
Ethyl acrylate Sorbitol
Ethyl Laevulinate Stearyl alcohol
Ethyl propionate Styrene acrylate (21)
Ethylene glycol Sulfur dioxide (25)
Ethylene oxide (25) Teflon (22)
Ethylhexanol Terephthalic acid esters
Ethylhexyl nitrate (14)
Ethyltoluene Tetrabromoethane
Fluorene Tetrachloroethane

https://www.gpsil.co.uk/our-products/karl-fischer-titrators/mkc-501n/ Page 4 of 13
Low Cost Coulometric Karl Fischer Titrator MKC-501N 4/9/18, 12)26 PM

Fluoroanisole Tetradecene (1)


Fluorophenol Transformer oil (3)
Formaldehyde Trichloroethane
Freons (25) Trimethylstyrene
Gasoline (5) (6) Trioxane
Geraniol Turbine oil (3)
Urea-formaldehyde resin
Vinyl chloride (25)
Vinylcyclohexane
Xylene

Pharmaceuticals, Flavours & Fragrances, Cosmetics


Baby oils Resorcinol dimethyl ether Standards
Almond oils Serotonin (13)
ASTM D 4928-11
Didecyl ether
Remarks (1) ... (26)
(/files/4413/9541/0330/karl-
fischer-
procedures_coulometric.jpg)

Technical Specifications

Type and MKC-501N Karl Fischer Titrator (coulometric)


model

Generator Without diaphragm, suitable for a wide range of different products


electrode except aldehydes, ketones and solvents with very low conductivity.

Measuring Water content 10 μg


range … 100
mg

Resolution 0.1 μg H2O

Limit of error Coefficient of variation 1 mg H2O in methanol (n=10) < 0.3


%

Drift Automatic compensation available


Drift is always shown on the display

Titration cell Anolyte minimum quantity 100


Internal volume max. mL
150

https://www.gpsil.co.uk/our-products/karl-fischer-titrators/mkc-501n/ Page 5 of 13
Low Cost Coulometric Karl Fischer Titrator MKC-501N 4/9/18, 12)26 PM

mL

Titration Pre-titration (excessive moisture)


status Ready (ready for titration but still no stable drift)
display Stable (drift is stable within 0.1 μg/min)

Endpoint Polarized twin Pt electrode (AC)


detection

Endpoint Display and beep


indication

Stirrer Magnetic stirrer, speed adjustable with keypad

Calculations Result units μg,


mg,
ppm,
%

Display LCD, 16 digits, 1 line

Displayed Results in mL, mg H2O, concentration (% or ppm) and messages


parameters

Displayed Polarization potential or liquid resistance out of range, etc.


alarms

Interfaces 3 RS-232C for printer, balance and PC

Printer IDP-100 dot matrix option

Ambient Temperature: 5 … 35 °C
conditions Rel. humidity < 85% (no condensation)

Power AC 100/120/220/230/240 V 50/60 Hz


supply

Power approx. 50 W
consumption

Dimensions 288 (W) × 468 (D) × 475 (H) mm

Weight approx. 7.5 kg

Software

https://www.gpsil.co.uk/our-products/karl-fischer-titrators/mkc-501n/ Page 6 of 13
Low Cost Coulometric Karl Fischer Titrator MKC-501N 4/9/18, 12)26 PM

Soft Cap Data Capture Software

The easy way to transfer your results directly


to Microsoft EXCEL
The Data Capture Software is an easy to use and flexible
solution to collect measurement results from different KEM
instruments (Refractometers, Density Meters, Potentiometric
or Karl-Fischer Titrators, Thermal Conductivity Meters) on a
Windows personal computer.

(/files/7313/9134/0283/SOFT- Up to four different instruments can be connected to one


CAP_zoom.jpg) single PC and be used simultaneously. Two of these
instruments can be of the same model.
The results can directly be stored in EXCEL workbooks.
The measured results are always available at a glance in a
clear and concise manner.
As soon as a measurement has finished, the result
appears in the corresponding worksheet.
The layout, order and the format how the results are
stored in EXCEL can freely be adapted to specific
needs.
Results can be automatically be processed by EXCEL
macros as they are transmitted to the PC. Additional
data (comments, sample data, etc.) can be entered at
any time by means of the PC keyboard or a barcode
reader.
All results can at the same time be stored in as CSV files.

System Requirements for PC

Specification Description

Computer Personal computer with Pentium II CPU of 233MHz or better

Operating system Microsoft Windows 2000, XP,


Vista (Home Basic, Business), 7 (Home Premium, Professional)

Other programs Microsoft EXCEL 97 / 2000 / 2003 / 2007

RAM at least 128 MB / 512 MB recommended

Hard disc space 10 MB required for installation

Display Resolution higher than 640 * 480

https://www.gpsil.co.uk/our-products/karl-fischer-titrators/mkc-501n/ Page 7 of 13
Low Cost Coulometric Karl Fischer Titrator MKC-501N 4/9/18, 12)26 PM

Disk drive CD-ROM or DVD-ROM

Interface 1 USB port


RS-232C D-sub (male) 9 pin required for each additional instrument
to be connected to the same computer.

Accessories

Printer

IDP-100 Printer
Dot matrix ink printer for GLP compliance.

Dot matrix printer with ink ribbon, prints on regular paper


(width 57.5 ± 0.5mm).
24 digits, 144 dots per line.
Automatic paper end detection - no loss of data!
2 kB internal buffer memory. Advantage: Less time
(/files/6813/9143/3302/IDP- required per measurement, as the instrument does not
100_zoom.jpg) have to wait until the results are printed out.

Evaporator

ADP-511: Accurate water determinations of


difficult samples
The ADP-511 substantially broadens the application
spectrum of your Karl Fischer Titrator. With this evaporator
accurate water determinations of samples which cannot be
titrated directly can be performed:

Substances which cause side reactions with the KF


reagent such as copper (II) salts, iron (III) salts, nitrites,
(/files/7713/9565/0731/adp-
motor oils with additives, etc.
511_zoom.jpg)
Substances that release water only at elevated
temperatures like plastics
Substances which would contaminate the titration cell like
coal dust, carbon black, etc.
Substances that are poorly soluble or insoluble such as
cotton, paper, compressed wood, etc.

https://www.gpsil.co.uk/our-products/karl-fischer-titrators/mkc-501n/ Page 8 of 13
Low Cost Coulometric Karl Fischer Titrator MKC-501N 4/9/18, 12)26 PM

The ADP-511 features a modern microprocessor control


ensuring maximum precision, reliability and user-friendliness:

Rapid rise and accurate control of the heating


temperature.
Digital display of temperature and flow rate.
Serial interface which enables the evaporator to be remote
controlled by the titrator when being used with an MKA-
520, MKS-520, MKC-520D or MKC-520N titrator.

To safely avoid contamination from atmospheric moisture the


ADP-511 is equipped with a remote controlled motor driven
magnetic bar to move the sample from the sample chamber
into the oven.

The heating chamber is equipped with an electrically


conductive transparent heater glass. This permits the sample
condition to be monitored during the vaporization process.

The ADP-511 comes with two built-in desiccant tubes for the
carrier gas. With an optional air pump, air instead of nitrogen
can be used as carrier gas.

Technical Specifications ADP-511

Heating Electrically conductive transparent


system heating glass

Temperature Range ambient … 300 °C


control Temperature sensor K-thermocouple
Temperature measurement precision ± 2 °C

Display Temperature or flow, LED, 3 digits

Heating Pyrex® glass tube 30 (ø) x 320 (L) mm


tube

Sample Pyrex® glass 68 (L) x 25 (W) x 15 (H) mm


boat Capacity 16 mL

Carrier gas Nitrogen (not included in supplied parts)


Air (air pump optional)
Gas flow rate 100 … 300 mL/min

Gas dryer Silicagel 100 g 1 pce (500 g Silicagel


included in supplied parts)

Zeolite 100 g 1 pce (500 g Zeolite


included in supplied parts)

https://www.gpsil.co.uk/our-products/karl-fischer-titrators/mkc-501n/ Page 9 of 13
Low Cost Coulometric Karl Fischer Titrator MKC-501N 4/9/18, 12)26 PM

Interface RS-232 9 pin male for communication


with KF titrator

Ambient Temperature: 5 … 35°C


conditions Humidity: < 85% RH

Power Supply 100 … 120 V, 200 … 240 V AC, 50/60 Hz


Consumption 150 W

Dimensions 297 (W) x 206 (D) x 330 (H) mm

Weight approx. 7 kg

Solvent Pump

Manually operated filling and emptying


system for titration cell
Direct contact with Karl Fischer Reagents should always be
avoided. This manually operated filling an emptying system
for the titration cell (ordering number 98-433-0134) protects
operators from direct contact with toxic reagents and vapors.

This solvent pump is included in the standard delivery of the


following Karl Fischer Titrators: MKS-520, MKA-520, MKC-
(/files/3213/9565/4909/manual_solvent_pump_zoom.jpg)
520D and MKC-520N.

Titration Cells
Part
Sketch Code Description

20- Transparent cell with drain cock (glass cell only)


040-
4200-
48

12- Transparent cell, complete, including generator electrode without


006- diaphragm, twin Pt electrode, washing bottle, funnel, KF grease,
7300- septum (10 pcs.) and anode adjuster
48

https://www.gpsil.co.uk/our-products/karl-fischer-titrators/mkc-501n/ Page 10 of 13
Low Cost Coulometric Karl Fischer Titrator MKC-501N 4/9/18, 12)26 PM

12- Transparent cell, complete, including generator electrode with


006- diaphragm, twin Pt electrode, washing bottle, funnel, KF grease,
7400- septum (10 pcs.) and anode adjuster
48

12- Transparent cell, including generator electrode without diaphragm and


006- twin Pt electrode
6200-
48

12- Transparent cell, including generator electrode with diaphragm and twin
006- Pt electrode
6100-
48

12- Transparent cell with drain cock, including generator electrode without
006- diaphragm and twin Pt electrode
6300-
48

12- Transparent cell with drain cock, including generator electrode with
006- diaphragm and twin Pt electrode
6400-
48

Samplers
Part
Sketch Code Description

98-740- Bent-type sampler for powders (1 … 1.5 mL)


3011

https://www.gpsil.co.uk/our-products/karl-fischer-titrators/mkc-501n/ Page 11 of 13
Low Cost Coulometric Karl Fischer Titrator MKC-501N 4/9/18, 12)26 PM

98-740- "C" bent-type sampler for powders


3020

98-740- Light weight sampler for powders


3025

98-740- Straight type light weight sampler


3026

98-740- Sampler for viscous products


3030

98-740- Sampler for highly viscous products


3031

98-433- Liquefied gas sampler with pressure vessel made of stainless


4013 steel (100 mL)

https://www.gpsil.co.uk/our-products/karl-fischer-titrators/mkc-501n/ Page 12 of 13
Low Cost Coulometric Karl Fischer Titrator MKC-501N 4/9/18, 12)26 PM

98-740- Sampler for oils


© 2017 GPS, Ltd. · Terms (/about-us/terms-and-conditions/) · Privacy (/about-us/privacy/) · Contact Back to top
(https://www.gpsil.co.uk/about-us/company-history/)3013

98-740- Spoon type sampler for viscous products


3012

98-740- Eggplant type sampler for powders


3024

98-500- Syringe (5 mL)


3166 Syringe (20 mL)
98-500-
3225

98-433- Stopper for syringe inlet port


3407

https://www.gpsil.co.uk/our-products/karl-fischer-titrators/mkc-501n/ Page 13 of 13

Вам также может понравиться