Procedure Description

P30305-X1118-G503-01-7618

EWSD

SYSTEM UPGRADE
Combined Upgrade
V11/CP113D to V17/CCNC/CP113E

Project STD

Issued by
Communications Division
Hofmannstraße 51, D-81359 München

Copyright Siemens AG 2005

The reproduction, transmission or use of this document or its contents is not permitted without express
written authority. Offenders will be liable for damages. All rights, including rights created by patent grant or
registration of a utility model or design, are reserved.
Technical modifications possible.
Technical specifications and features are binding only insofar as they are specifically and expressly agreed
upon in a written contract.
────────────────────────────────────────────────
SIEMENS AKTIENGESELLSCHAFT

Author: L.Stefak, PSE SMC CI M


Translator:
In addition to the author on the cover page, the following persons have collaborated on this
document:

H. Bayer, PSE SMC CI M

The document comprises 232 pages, all pages have issue no 01

0-2 P30305-X1118-G503-01-7618
TABLE OF CONTENTS

1. INTRODUCTION............................................................................................................. 1-1
1.1. Subject of the Description.................................................................................... 1-1
1.2. Objective of the Procedure .................................................................................. 1-1
1.3. Phases of the Procedure ..................................................................................... 1-2
1.4. Position in the Process with Procedure Interfaces .............................................. 1-3
1.5. Scope of HW/FW/SW to be upgraded ................................................................. 1-4
1.6. Aspects of Quality................................................................................................ 1-4
1.6.1. Protection against Electrostatic Discharge ............................................ 1-4
1.6.2. Handling of HW / FW Changes.............................................................. 1-4
1.7. How to read this Procedure ................................................................................. 1-5

2. PREREQUISITES ........................................................................................................... 2-1


2.1. Hardware / Firmware ........................................................................................... 2-1
2.1.1. Required Status ..................................................................................... 2-1
2.1.1.1. Compatible SW / HW / FW Modifications..................................... 2-1
2.1.1.2. Non-compatible HW/FW Modifications ........................................ 2-1
2.1.2. Additional Equipment for System Upgrade ............................................ 2-1
2.2. Test / Reference System ..................................................................................... 2-2
2.3. Installation Requirements .................................................................................... 2-2
2.4. Software / Tools................................................................................................... 2-3
2.4.1. APS V17/CCNC ..................................................................................... 2-3
2.4.2. System Upgrade - Command Files........................................................ 2-4
2.4.2.1. Command files V11:..................................................................... 2-4
2.4.2.2. Command files V17/CCNC: ......................................................... 2-4
2.4.3. System Upgrade - Patch Files ............................................................... 2-5
2.4.3.1. Patch files APS V11 ..................................................................... 2-5
2.4.3.2. Patch files APS V17/CCNC.......................................................... 2-5
2.4.4. Common Patches .................................................................................. 2-5
2.5. Documentation..................................................................................................... 2-5

3. BASIC OPERATION....................................................................................................... 3-1


3.1. Overview / Flow Diagram..................................................................................... 3-1
3.1.1. Phase 1: Preparation ............................................................................. 3-2
3.1.2. Phase 2: CP Change ............................................................................. 3-6
3.1.3. Phase 3: Cut Over ................................................................................. 3-8
3.1.4. Phase 4: Post-Processing ................................................................... 3-10

4. PHASE 1: PREPARATION............................................................................................. 4-1


4.1. Installation............................................................................................................ 4-1
4.1.1. Installation of CP113E ........................................................................... 4-1
4.1.2. Cabling of CP113E ................................................................................ 4-2
4.1.3. Cabling of CP113D ................................................................................ 4-3
4.2. Establishing a Test Concept ................................................................................ 4-4
4.3. Transferring V11 Command and Patch Files to Disks / CP113D ........................ 4-5
4.4. Test of the CP113D ............................................................................................. 4-5
4.5. Diagnosis of the Periphery / CP113D .................................................................. 4-6
4.5.1. Verification of MB / SN Capacity Stages ............................................... 4-6
4.5.1.1. MBULs without TSGs are in PLA ................................................. 4-7
4.5.2. Diagnosis of the MB............................................................................... 4-7
4.5.3. Diagnosis of the SN ............................................................................... 4-8

P30305-X1118-G503-01-7618 0-3
4.5.4. Check of the CCG - IOPMB Connection ................................................ 4-9
4.5.5. Check of the SYPC - IOPMB Connection ............................................ 4-10
4.5.6. Diagnosis of the CCNC ........................................................................ 4-10
4.5.7. Checking the LTGs .............................................................................. 4-11
4.6. System Test / CP113D ...................................................................................... 4-11
4.7. Saving of the actual APS V11 / CP113D ........................................................... 4-12
4.8. Saving of System Files / CP113D...................................................................... 4-12
4.9. Preparation of APS V11 / CP113D .................................................................... 4-15
4.10. Loading the APS V17/CCNC from MOD / CP113E ........................................... 4-16
4.11. Installation Recovery with complete APS V17/CCNC CP113E ......................... 4-21
4.12. Checking the Validation of the new Generation CP113E .................................. 4-26
4.13. Deactivation of Routine Tests ............................................................................ 4-26
4.13.1. Deactivation of Routine Tests CP113D/V11 ........................................ 4-26
4.13.2. Deactivation of Routine Tests CP113E/V17/CCNC ............................. 4-26
4.14. Transferring V17/CCNC Command Files to Disks CP113E............................... 4-26
4.15. Activation of BAP-1 CP113E.............................................................................. 4-27
4.16. Activation of MDD-1 CP113E............................................................................. 4-27
4.17. Activating IOPMBs CP113E............................................................................... 4-27
4.18. Activation of CAPs CP113E............................................................................... 4-28
4.19. Check Creation of CSC-Links CP113E.............................................................. 4-28
4.20. Check Creation of X25-Links CP113E............................................................... 4-28
4.21. Configuration of links CP113E ........................................................................... 4-29
4.22. Test of the CP113E............................................................................................ 4-29
4.23. Creating and Checking Files CP113E ............................................................... 4-30
4.23.1. Starting Processes ............................................................................... 4-30
4.23.2. Checking and Creating CA Files .......................................................... 4-30
4.23.3. Checking and Creating IA Files ........................................................... 4-31
4.23.4. Checking and Craeting IACHASTA Registration ................................. 4-32
4.23.5. Checking Security Files ....................................................................... 4-33
4.24. Changing Meter Saving Time / CP113E ............................................................ 4-33
4.25. Checking Data for Meter Administration CP113D / CP113E ............................. 4-33
4.26. Handling of ALIAS Names ................................................................................. 4-34
4.26.1. Checking ALIAS Names....................................................................... 4-34
4.26.2. Incorporating ALIAS Names................................................................. 4-34
4.27. Processing Logfile (1) / CP113D........................................................................ 4-34
4.27.1. Checking for Security Keywords .......................................................... 4-35
4.27.2. Checking the Logfile ............................................................................ 4-36
4.27.3. Saving and Converting Logfile (1) / Dest. APS V17/CCNC ................. 4-37
4.28. Switch over of CCNP-1 from CP113D to CP113E ............................................. 4-38
4.28.1. Deactivation of CCNP-1 in V11............................................................ 4-38
4.28.2. Disconnection of CCNP-1 from CP113D ............................................. 4-38
4.28.3. Connection of CCNP-1 to CP113E ...................................................... 4-38
4.28.4. Activation of CCNP-1 in V17/CCNC..................................................... 4-38
4.29. Incorporating the Logfile (1) / CP113E............................................................... 4-39
4.30. Checking System Availability of APS V11 / CP113D ......................................... 4-41
4.31. Checking the LTG States CP113D / CP113E.................................................... 4-42
4.32. Checking the SN States / CP113E .................................................................... 4-44
4.33. Checking the MB(B) States / CP113E ............................................................... 4-45
4.34. Checking the CCNP States / CP113E ............................................................... 4-46
4.35. CCG Status Request / CP113E ......................................................................... 4-46
4.36. SYP Status Request / CP113E.......................................................................... 4-47
4.37. Interrogation of DIU and CR States ................................................................... 4-47
4.38. Deactivation of CSC- and X25-Links / CP113D ................................................. 4-48
4.38.1. Deactivating CSC-Links ....................................................................... 4-48
4.38.2. Deactivating X25-Links ........................................................................ 4-48

0-4 P30305-X1118-G503-01-7618
4.39. Blocking Subscriber Entries / CP113D .............................................................. 4-48
4.40. Processing Logfile (2) / CP113D ....................................................................... 4-49
4.40.1. Checking for Security Keywords .......................................................... 4-49
4.40.2. Checking the Logfile ............................................................................ 4-50
4.40.3. Saving and Converting Logfile (2) / Dest. APS V17/CCNC ................. 4-51
4.41. Incorporating the Logfile (2) / CP113E .............................................................. 4-52

5. PHASE 2: CP CHANGE ................................................................................................. 5-1


5.1. Switch over MB/CCG/SN-1, SYPC from CP113D to CP113E............................. 5-1
5.1.1. Deactivation of SN/MB/CCG-1, SYPC / CP113D .................................. 5-1
5.1.2. Disconnecting MB/CCG-1 and SYPC from CP113D ............................. 5-2
5.1.3. Connecting MB/CCG-1 and SYPC to CP113E ...................................... 5-3
5.1.4. Check of MB(B) – IOPMB connection / CP113E ................................... 5-3
5.2. Blocking Subscriber Controlled Inputs/CP113E .................................................. 5-5
5.3. Updating the Charge Files / CP113D .................................................................. 5-5
5.4. Deactivation of MDD-1 / CP113D ........................................................................ 5-5

6. PHASE 3: CUT OVER .................................................................................................... 6-1


6.1. Stopping System CP113D APS V11 ................................................................... 6-1
6.2. Switch over MB/CCG/SN/CCNP-0 from CP113D to CP113E ............................. 6-2
6.2.1. Disconnecting MB/CCG/CCNP-0 from CP113D.................................... 6-2
6.2.2. Connecting MB/CCG/CCNP-0 and SYPC to CP113E........................... 6-3
6.3. Ending Installation Recovery / CP113E............................................................... 6-4
6.4. Startup of the CP113E System with ISTART2F, APS V17/CCNC....................... 6-4
6.5. Manual Startup of the CP113E System APS V17/CCNC .................................... 6-7
6.6. System Status Inquiry / CP113E ......................................................................... 6-8
6.7. Activating CAPs / CP113E................................................................................... 6-9
6.8. System Test APS V17/CCNC / CP113E ........................................................... 6-10

7. PHASE 4: POST - PROCESSING .................................................................................. 7-1


7.1. Checking Charge Files / CP113E ........................................................................ 7-1
7.2. Restoring original Charge Meter Saving / CP113E ............................................. 7-1
7.3. Unblocking Subscriber Controlled Inputs / CP113E ............................................ 7-2
7.4. Updating the Database / CP113E........................................................................ 7-2
7.5. Switch over CSC-Links from CP113D to CP113E............................................... 7-2
7.5.1. Disconnecting CSC-Links from CP113D ............................................... 7-2
7.5.2. Connecting CSC-Links to the CP113E .................................................. 7-2
7.5.3. Disconnecting X25-Links from CP113D ................................................ 7-3
7.5.4. Connecting X25-Links to the CP113E ................................................... 7-3
7.6. Activating Routine Tests ...................................................................................... 7-3
7.7. Starting Installation Recovery APS V11 / CP113D.............................................. 7-4
7.8. Starting Processes / CP113D .............................................................................. 7-5
7.9. Unblocking Subscriber Controlled Imputs............................................................ 7-5
7.10. File handling CP113D.......................................................................................... 7-6
7.10.1. Saving IA Files / CP113D ...................................................................... 7-6
7.10.1.1. Saving File IA.ICAMA / CP113D .................................................. 7-6
7.10.1.2. Saving File IA.ICMAL / CP113D .................................................. 7-7
7.10.1.3. Saving File IA.ICMOB and IA.ICFIR / CP113D............................ 7-7
7.10.1.4. Saving File IA.ICIAR / CP113D.................................................... 7-8
7.10.1.5. Saving Files IA.ICIAR1 and IA.ICIAR2 / CP113D ........................ 7-9
7.10.1.6. Saving File IA.ICINA / CP113D.................................................... 7-9
7.10.2. Saving File IA.IC<type> / CP113D....................................................... 7-10
7.10.3. Saving IACHASTA Files / CP113D...................................................... 7-10
7.10.4. Saving Security Files / CP113D........................................................... 7-11

P30305-X1118-G503-01-7618 0-5
7.10.5. Saving CA Files for Meter Accounting / CP113D................................. 7-11
7.10.6. Saving CA Files for Meter Regeneration / CP113D ............................. 7-12
7.11. Regeneration of Charge Meters / CP113E ........................................................ 7-13
7.12. Stop Installation Recovery / CP113D................................................................. 7-14
7.13. Diagnosis of the Periphery / CP113E ................................................................ 7-15
7.13.1. Diagnosis of the MB ............................................................................. 7-15
7.13.2. Diagnosis of the SN ............................................................................. 7-16
7.13.3. Check of CCG - IOPMB Connection .................................................... 7-17
7.13.4. Check of SYPC - IOPMB Connection .................................................. 7-17
7.13.5. Diagnosis of CCNC .............................................................................. 7-18
7.14. Deleting Command Files / CP113E ................................................................... 7-18
7.15. Removing the MP .............................................................................................. 7-18
7.16. Setting the Upgrade Option ............................................................................... 7-19
7.17. Starting Jobs / CP113E...................................................................................... 7-19
7.18. Saving APS V17/CCNC / CP113E..................................................................... 7-19
7.19. Casino Outage Report ....................................................................................... 7-19

8. INTERRUPTING THE UPGRADE PROCEDURE........................................................... 8-1


8.1. Blocking Subscriber Entries / CP113E................................................................. 8-1
8.2. Deactivating Links / CP113E ............................................................................... 8-1
8.2.1. Deactivation of CSC-Links / CP113E..................................................... 8-1
8.2.2. Deactivation of X25-Links / CP113E ...................................................... 8-2
8.3. Saving Logfile / CP113E ...................................................................................... 8-2
8.4. Updating Charge Files on Disk / CP113E............................................................ 8-3
8.5. Stopping System V17/CCNC / CP113E............................................................... 8-3
8.6. Disconnection of MB/CCG/CCNP-1 and SYPC from CP113E ............................ 8-4
8.7. Disconnection of MB/CCG/CCNP-0 from CP113E .............................................. 8-5
8.8. Connection of MB/CCG/CCNP-0 to CP113D....................................................... 8-6
8.9. Connection of MB/CCG/CCNP-1 and SYPC to CP113D..................................... 8-7
8.10. Installation Recovery of V11/ CP113D................................................................. 8-8
8.11. Configuration of the periphery.............................................................................. 8-9
8.12. Ending the Installation Recovery of APS V11...................................................... 8-9
8.13. Startup of APS V11 with ISTART2F .................................................................... 8-9
8.14. System Status Inquiry / CP113D ....................................................................... 8-10
8.15. Unblocking Subscriber Controlled Imputs.......................................................... 8-12
8.16. Systemtest / CP113D......................................................................................... 8-12
8.17. Incorporating Logfile / CP113D.......................................................................... 8-12
8.18. Checking the Charge Files / CP113D ................................................................ 8-13
8.18.1. Check and Creation of CA- and MS-Files ............................................ 8-13
8.18.2. Check and Creation of IA-Files ............................................................ 8-14
8.18.3. Check and Creation of IARSTAT-Files ................................................ 8-14
8.19. Restoring original Meter Saving Points / CP113D ............................................. 8-14
8.20. Activating CCG-1/CCNP-1 and SYP / CP113D ................................................. 8-15
8.21. Activation of MDD-1 / CP113D .......................................................................... 8-15
8.22. Change over of Links ......................................................................................... 8-15
8.22.1. Change over of CSC-Links from CP113E to CP113D ......................... 8-15
8.22.2. Change over of X25-Links from CP113E to CP113D .......................... 8-16
8.23. Start of the Installation Recovery / CP113E....................................................... 8-17
8.24. Starting Processes / CP113E ............................................................................ 8-18
8.25. Saving Charge Files / CP113E .......................................................................... 8-18
8.26. Stop Installation Recovery / CP113E................................................................. 8-18
8.27. Diagnosis of the Periphery / CP113D ................................................................ 8-19
8.28. Activating Routine Tests / CP113D.................................................................... 8-19
8.29. Deleting auxiliary Files / CP113D ...................................................................... 8-19
8.30. Saving of APS V11 / CP113D............................................................................ 8-19

0-6 P30305-X1118-G503-01-7618
9. PROJECT RELATED ITEMS ......................................................................................... 9-1
9.1. Downward-compatible HW/FW Modifications:..................................................... 9-1
9.2. Not downward-compatible HW/FW Modifications:............................................... 9-1

10. ABBREVIATIONS......................................................................................................... 10-1

11. REFERENCES.............................................................................................................. 11-1

12. APPENDIX .................................................................................................................... 12-1


12.1. CP113D ............................................................................................................. 12-1
12.1.1. CP113D Racks for Capacity Stage up to DE54................................... 12-1
12.1.2. CP113D Frames for Capacity Stage up to DE52................................. 12-2
12.1.3. CP113D Frames for Capacity Stage DE54.......................................... 12-3
12.1.4. Allocation of log./phys. IOPMB/IOPLAU to Periphery.......................... 12-4
12.2. CP113E ............................................................................................................. 12-5
12.2.1. CP113E Rack ...................................................................................... 12-5
12.2.2. CP113E Frame F:BPCE ...................................................................... 12-6
12.2.3. CP113E Frame F:EPCE ...................................................................... 12-7
12.2.4. CP113E Frame F:EIOP classic IOC 0 + 1 ........................................... 12-8
12.2.5. CP113E Extension Frame F:PIOP classic IOC 2 + 3 ........................ 12-10
12.2.6. Allocation of Log./Phys. IOP’s to the Periphery ................................. 12-11
12.3. Message Buffer MB(B) .................................................................................... 12-12
12.3.1. Frame Equipping MB(B) .................................................................... 12-13
12.3.2. Notes on Cabling the MB(B) .............................................................. 12-14
12.3.3. Notes on Cabling the CCNC .............................................................. 12-14
12.4. Standard Cabling ............................................................................................. 12-15
12.4.1. Cabling CP113D, CP113E - MB/CCG(B), Cable Group P................. 12-16
12.4.1.1. Connecting Cables IOP-0,1,2,3 - MB-1,3,5,7 and CCG-1 ...... 12-16
12.4.1.2. Connecting Cables IOP-0,1,2,3 - MB-0,2,4,6 and CCG-0 ...... 12-17
12.4.2. Cables CP113D, CP113E - SYPC(A), Cables Group P ................. 12-18
12.4.3. Cable CP113D, CP113E - CCNC, Cable Group P ............................ 12-18
12.4.3.1. Connecting Cables IOP-0,1 - CCNP-1..................................... 12-18
12.4.3.2. Connecting Cables IOP-0,1 - CCNP-0..................................... 12-19
12.5. Command Files V11 ........................................................................................ 12-20
12.5.1. Command File CF.11.ACTCSCG503 ................................................ 12-20
12.5.2. Command File CF.11.ACTX25G503 ................................................. 12-21
12.5.3. Command File CF.11.CPTESTG503................................................. 12-22
12.5.4. Command File CF.11.DIAGCCNG503 .............................................. 12-24
12.5.5. Command File CF.11.DIAGMB0G503............................................... 12-27
12.5.6. Command File CF.11.DIAGMB1G503............................................... 12-30
12.5.7. Command File CF.11.MBSNPLAG503.............................................. 12-33
12.5.8. Command File CF.11.DIUSTATG503................................................ 12-36
12.5.9. Command File CF.11.PLACSCG503................................................. 12-39
12.5.10. Command File CF.11.PLAX25G503.................................................. 12-40
12.5.11. Command File CF.11.REGMEMOG503 ............................................ 12-41
12.5.12. Command File CF.11.PROG503 ....................................................... 12-45
12.5.13. Command File CF.11.SYSTATG503 ................................................. 12-46
12.5.14. Command File CF.11.UPDFILEG503................................................ 12-49
12.5.15. Command File CF.11.V5CHECKG503 .............................................. 12-52
12.6. Command Files V17/CCNC............................................................................. 12-53
12.6.1. Command File CF.17.ACTCAPG503 ................................................ 12-53
12.6.2. Command File CF.17.ACTCSCG503 ................................................ 12-55
12.6.3. Command File CF.17.ACTX25G503 ................................................. 12-56

P30305-X1118-G503-01-7618 0-7
12.6.4. Command File CF.17.ACTIOPG503.................................................. 12-57
12.6.5. Command File CF.17.DIAGCCNG503............................................... 12-59
12.6.6. Command File CF.17.DIAGMB0G503 ............................................... 12-61
12.6.7. Command File CF.17.DIAGMB1G503 ............................................... 12-63
12.6.8. Command File CF.17.DIUSTATG503................................................ 12-65
12.6.9. Command File CF.17.HEXLTGG503................................................. 12-66
12.6.10. Command File CF.17.HEXMBBG503 ................................................ 12-67
12.6.11. Command File CF.17.HEXSNBG503 ................................................ 12-68
12.6.12. Command File CF.17.PLACSCG503................................................. 12-69
12.6.13. Command File CF.17.PLAX25G503 .................................................. 12-70
12.6.14. Command File CF.17.PLAMBBG503................................................. 12-71
12.6.15. Command File CF.17.PROG503 ....................................................... 12-73
12.6.16. Command File CF.17.SYSTATG503 ................................................. 12-74
12.6.17. Command File CF.17.UPDFILEG503 ................................................ 12-76
12.7. Patch Files V11................................................................................................ 12-78
12.7.1. Patch File PA.11.B2925L2Z............................................................... 12-78
12.7.2. Patch File PA.11.B2925L2J ............................................................... 12-81
12.8. Patch Files V17/CCNC .................................................................................... 12-82

13. CHANGE REQUESTS TO THE SYSTEM UPGRADE PROCEDURE.......................... 13-1

0-8 P30305-X1118-G503-01-7618
1. INTRODUCTION

1.1. Subject of the Description


This document describes the procedure used for performing a Combined System Upgrade
from CP113D APS V11 to CP113E APS V17/CCNC. The procedure covers the case, that the
same periphery MB/SN/CCNC is used for both CPs.

Please note that any changes to the contents of this procedure must first be approved by
PSE SMC CI M in good time (2 weeks before the first application). Suggested modifications,
see Chapter 13, must be submitted contacting PSE SMC CI M:

• FAX: +421 41 5055 809

• Internet Mail: ludovit.stefak@siemens.com

1.2. Objective of the Procedure


This basic procedure is designed to support the HW/SW upgrade in the field. Keeping the
system interruption or any restriction of switching operations during the performance as low as
possible is the main objective.
The conversion to the new SW version only takes into consideration the features of the old
version. Features of the target version have to be implemented after the upgrade.

In this procedure description, the required activities are handled in detail and in chronological
order.

P30305-X1118-G503-01-7618 1-1
1.3. Phases of the Procedure
The System Upgrade procedure is divided into four phases:

Phase 1 Preparation

All preparatory operations which can be done before (not time critical) are carried out in this
phase.

• Installation and cabling of CP113E


• Diagnosis of CP113D and periphery
• Saving of the actual APS V11
• Saving of system files CP113D
• Preparation of APS V11 CP113D for the CP-change
• Loading APS V17/CCNC and starting Installation Recovery CP113E
• Test of CP113E
• Processing logfile (1) CP113D
• Switch over of CCNP-1 from CP113D to CP113E
• Incorporating the logfile (1) / CP113E
• Check of system availability APS V11 / CP113D
• Check of the states / CP113E
• Processing logfile (2) CP113D
• Incorporating the logfile (2) / CP113E

Phase 2 CP-Change

• Change over of MB/CCG/SN-1 and SYPC from CP113D to CP113E


• Updating charge files / CP113D
• Deactivation of MDD-1 / CP113D

Phase 3 Cut Over

• Stopping system APS V11/ CP113D


• Change over of MB/CCG/SN/CCNP-0 from CP113D to CP113E
• Ending Installation Recovery CP113E
• Startup of CP113E system with ISTART2F APS V17/CCNC
• Checking system availability APS V17/CCNC CP113E and system test

1-2 P30305-X1118-G503-01-7618
Phase 4 Post-Processing

• Checking charge files / CP113E


• Change over of CSC- and X25-links from CP113D to CP113E
• Start of Installation Recovery APSV11 / CP113D
• Charge file handling CP113D
• Regeneration of Charge meters CP113E
• Stop installation recovery / CP113D
• Diagnosis of periphery CP113E
• Saving of APS V17/CCNC CP113E

1.4. Position in the Process with Procedure Interfaces


The following shows the process System Upgrade with all the procedures and the position of
the Upgrade Procedure.

PROCESS System Upgrade V11 to V17/CCNC

PROCEDURE Database Regeneration in V11 /1/

PROCEDURE Database Handling V9….V17 to V17 /2/

PROCEDURE Database Installation V17/CCNC /3/

Upgrade Procedure
PROCEDURE
Combined Upgrade V11/CP113D to V17/CCNC/CP113E

P30305-X1118-G503-01-7618 1-3
1.5. Scope of HW/FW/SW to be upgraded

Units Original State Target State

APS SW V11 V17/CCNC

Processor HW CP113D CP113E

Message Buffer HW MB/CCG(B) same

Switching Network HW SN(A) or SN(B) same

CCNC HW CCNC same

1.6. Aspects of Quality

1.6.1. Protection against Electrostatic Discharge

Follow the Guidelines for the Protection of


Electrostatic Sensitive Devices

Note : When working on EWSD systems always ensure that static


electricity is discharged.

Therefore : Put on your armband and connect it to ground before pulling


or plugging modules or cables.

Use a conductive, grounded surface when working on


modules.

Use only the appropriate protective bags for transport.

1.6.2. Handling of HW / FW Changes


Before the System Upgrade, all downward-compatible HW / FW changes must have been
implemented and diagnosed.

The FW-modifications have to be done as far as possible on spare modules, which have to be
diagnosed in a test switch before use.

1-4 P30305-X1118-G503-01-7618
1.7. How to read this Procedure
When executing this procedure, the meaning of the following symbols should be well known:

CP113E

Enter command on OMT-0 of CP113E

CP113E

Enter command on OMT-1 of CP113E

CP113E

/ Enter command optionally on OMT-0 or OMT-1 of CP113E

CP113D

Enter command on OMT-0 of CP113D

CP113D

Enter command on OMT-1 of CP113D

CP113D

/ Enter command optionally on OMT-0 or OMT-1 of CP113D

PC Enter command on PC

Commands in bold letters are mandatory.


Commands in normal letters are optional (usually used after check of required status).

Operator intervention

! Check the required status which is described here

Jump with condition

Jump without condition

P30305-X1118-G503-01-7618 1-5
This page was left intentionally blank!

1-6 P30305-X1118-G503-01-7618
2. PREREQUISITES

2.1. Hardware / Firmware

2.1.1. Required Status


The new equipment CP113E must be installed with the actual HW / FW versions for APS
V17/CCNC.

2.1.1.1. Compatible SW / HW / FW Modifications


If downward compatible HW or FW changes are found that have not yet been carried out, they
must be implemented and diagnosed without faults before the System Upgrade starts (as soon
as possible).

2.1.1.2. Non-compatible HW/FW Modifications


*** No entry ***

2.1.2. Additional Equipment for System Upgrade


A Maintenance Panel MP for the CP113E is recommended. The MP does not belong to the
standard equipment of CP113E, it should be obtainable in the local TAC department.

P30305-X1118-G503-01-7618 2-1
2.2. Test / Reference System
*** No entry ***

2.3. Installation Requirements


• Advance space provisions:
Enough space must be provided in advance for the additional CP racks and for air-
conditioning and ventilation.

• Power supply:
The existing system power supply must be adapted to meet the new power requirements

• Installation of new racks:


The new CP racks have to be installed on a free space under consideration that the
maximum cable length between CP and MB, CCNC is 35 meters

• General notes on the configuration:


The following basic points should always be observed while installing the new equipment.

ο The revision level of the racks, frames, modules and cable lettering must have been
checked and correspond with the actual status.

ο New racks and/or frames must be firmly screwed in.

ο The new rack wiring must be laid and completed (internal cabling, power supply and
ground connections).

ο New voltage converters DCCs must be mounted and connected.

ο The wrap field side of the new frames must be examined for bent wrap pins, loose wires,
short-circuits, foreign bodies, etc.

ο All new modules in equipment not in operation - i.e., in the new racks and frames, must
be in position but not inserted.

ο Check that all new modules are in the correct mounting location.

ο All new modules for devices already in operation must be in position but not inserted.
Check that all new modules are in the correct mounting location.

ο All new cables must be laid up to the rack frames. They are only permitted to be inserted
in the sides not in operation; the new cables must not be inserted in the equipment in
operation.

ο Carefully examine the cable labeling at both connector ends for correctness. Check that
all new cable connectors are at the correct location.

ο The cable ends of new cables must be marked in color in order to clearly distinguish them
from the old cables.

2-2 P30305-X1118-G503-01-7618
2.4. Software / Tools

2.4.1. APS V17/CCNC


The APS of the new system generation V17/CCNC is available on magneto optical disk MO.
It contains the following system files:

Complete APS V17/CCNC:

File Content
SY.INSTALL Installation monitor
SY.GENLIST List of generations
SY.TASKLIB CP software (resident part)
SY.LOADLIB.LA Library of reloadable processes
SY.LOADLIB.MA Library of masks
SY.LOADLIB.CA Non-resident command description
SY.PSW.Txxx xxx = LTG load types
SY.PSW.T097 CCNC SW: CPI
SY.PSW.T098 CCNC SW: SIMP code
SY.SIMP CCNC SW: SIMP database
SY.PSW.T100 IOP:SCDP SW
SY.PSW.T121 IOP:UNI SW
SY.PSW.T122 IOP:UNI SW (Typ2)
SY.SEMILIB Library of semipermanent data
SY.UPLOG Logging file for SY.SEMILIB
SY.VSD.BACKUP Library for VSD database (Subscriber controlled inputs SCI)
SY.MSGXREF Reference list of messages

The APS is completely installed and comprises:

All CP patches
All GP patches
All CCNC patches
ODAGEN extension
Database

Additionally the following charge files may be available:

CA.SU.UCHA Subscriber meter charge file


CA.TF.UCHA Subscriber meter charge file S130
etc

P30305-X1118-G503-01-7618 2-3
2.4.2. System Upgrade - Command Files
The execution of the procedure is supported by command files. The following command files
are available:

2.4.2.1. Command files V11:


File Content
CF.11.ACTCSCG503 Activation of CSC-links (CSC-0..3)
CF.11.ACTX25G503 Activation of X25-links (X25LINK-0...7)
CF.11.CPTESTG503 Diagnosis of CP113E
CF.11.DIAGCCNG503 Diagnosis of CCNC
CF.11.DIAGMB0G503 Diagnosis of MB0
CF.11.DIAGMB1G503 Diagnosis of MB1
CF.11.DIUSTATG503 Checking DIU and CR states
CF.11.MBSNPLAG503 Configuration of MB and SN to PLA (Fallback)
CF.11.PLACSCG503 Configuration of CSC-links to PLA (CSC-0..3)
CF.11.PLAX25G503 Configuration of X25-links to PLA (X25LINK-0...7)
CF.11.REGMEMOG503 Creating regeneration magneto optical disk MO in MOD-0
CF.11.PROG503 Starting processes in the Installation Recovery
CF.11.SYSTATG503 Checking the system status
CF.11.UPDFILEG503 Updating charge files on disks
CF.11.V5CHECKG503 Checking V5.1-link distribution

2.4.2.2. Command files V17/CCNC:


File Content
CF.17.ACTCAPG503 Activation of CAPs (CAP-0 up to CAP-5)
CF.17.ACTCSCG503 Activation of CSC-links (CSC-0..3)
CF.17.ACTX25G503 Activation of X25-links (X25LINK-0...7)
CF.17.ACTIOPG503 Activation IOPMB’s
CF.17.DIAGCCNG503 Diagnosis of CCNC
CF.17.DIAGMB0G503 Diagnosis of MB0
CF.17.DIAGMB1G503 Diagnosis of MB1
CF.17.DIUSTATG503 Checking DIU and CR states
CF.17.HEXLTGG503 Display of semipermanent status table LTG
CF.17.HEXMBBG503 Display of semipermanent status table MB(B)
CF.17.HEXSNBG503 Display of semipermanent status table SN(B)
CF.17.PLACSCG503 Configuration of CSC-links to PLA (CSC-0..3)
CF.17.PLAMBBG503 Configuration of MB(B)-units to PLA
CF.17.PLAX25G503 Configuration of X25-links to PLA (X25LINK-0...7)
CF.17.PROG503 Starting processes in the Installation Recovery
CF.17.SYSTATG503 Checking the system status
CF.17.UPDFILEG503 Updating charge files on disk

2-4 P30305-X1118-G503-01-7618
2.4.3. System Upgrade - Patch Files
The execution of the procedure is supported by patch files. The following patch files are
available:

2.4.3.1. Patch files APS V11


PA.11.B2925L2Z Blocking subscriber controlled inputs
PA.11.B2925L2J Backout patch for patch B2925L2Z

2.4.3.2. Patch files APS V17/CCNC


*** None ***

2.4.4. Common Patches


All released patch sets have to be updated in APS V11 and in V17/CCNC.

2.5. Documentation
For execution of the System Upgrade procedure, the following manuals are necessary:

MMN:CP113 V11
NM:CP113 V11
MMN:SW:CP113 V11
MMN:CCS7 V11
MMN:CP113E V17/CCNC
NM:CP113 V17/CCNC
MMN:SW:CP113 V17/CCNC
MMN:CCS7 V17/CCNC V17/CCNC

P30305-X1118-G503-01-7618 2-5
This page was left intentionally blank!

2-6 P30305-X1118-G503-01-7618
3. BASIC OPERATION

3.1. Overview / Flow Diagram


The following pages represent an outline of the Upgrade Procedure.

For each phase, a synoptical diagram is depicted on the left page of the document. A short
description in form of a flow diagram is arranged on each right page.

P30305-X1118-G503-01-7618 3-1
3.1.1. Phase 1: Preparation
Switching Switching network
i h

LTG SN-1

SN-0

LTG

Communication
interface

Phase 1:
Prelaying new cables from CP113E to
MB/CCG/CCNP-0,1 and SYPC MB-1
S
Y
MB-0 P
C

Central
control

Phase 1: Phase 1:
IOPMB/CCG/SYP IOPMB/CCG/SYP
- Installation of - CP113D on line
- Test of CP and
CP113E
periphery
- Loading APS V17 CP113E CP113D
- Processing logfile
- Install. Recovery
- Test of CP
- Incorporating
logfile
- CP113E stand DEV D0
alone

3-2 P30305-X1118-G503-01-7618
Phase 1: Preparation

To be started several days before the upgrade

CP113E side CP113D side

Installation of : 4.1.1 CP113D on line with APS V11


R:CP113E and MP:CP113E MB/CCG(B), SN, CCNC

Cabling of : 4.1.2
Prelaying connecting cables
CP113E - MB/CCG(B),SYPC,CCNC
CP113E - CSC- and X25-links

Cabling of CP113D 4.1.3

Establishing a Test Concept 4.2

Transferring V11 Command and Patch 4.3


Files to Disks / CP113D

Test of the CP113D 4.4

Diagnosis of the Periphery / CP113D 4.5

System Test / CP113D 4.6

Saving of the actual APS V11 / CP113D 4.7

Saving of System Files / CP113D 4.8

Preparation of APS V11 / CP113D 4.9

Loading the APS V17/CCNC from 4.10


MOD / CP113E

Installation Recovery with complete 4.11


APS V17/CCNC CP113E

Checking the Validation of the new 4.12


Generation CP113E

Deactivation of Routine Tests 4.13

Transferring V17/CCNC Command 4.14


Files to Disks CP113E

Activation of BAP-1 CP113E 4.15

Activation of MDD-1 CP113E 4.16

Activating IOPMBs CP113E 4.17

Activation of CAPs CP113E 4.18

P30305-X1118-G503-01-7618 3-3
Check Creation of CSC-Links CP113E 4.19

Check Creation of X25-Links CP113E 4.20

Configuration of links CP113E 4.21

Test of the CP113E 4.22

Creating and Checking Files CP113E 4.23

Changing Meter Saving Time / CP113E 4.24

Checking Data for Meter Administration CP113D / CP113E 4.25

Handling of ALIAS Names 4.26

Processing Logfile (1) / CP113D 4.27

Switch over of CCNP-1 from CP113D to CP113E 4.28

Incorporating the Logfile (1) / CP113E 4.29

Checking System Availability of APS V11 / 4.30


CP113D

Checking the LTG States CP113D / CP113E 4.31

Checking the SN States / CP113E 4.32

Checking the MB(B) States / CP113E 4.33

Checking the CCNP States / CP113E 4.34

CCG Status Request / CP113E 4.35

SYP Status Request / CP113E 4.36

Interrogation of DIU and CR States 4.37

Deactivation of CSC- and X25-Links / CP113D 4.38

Blocking Subscriber Entries / CP113D 4.39

Processing Logfile (2) / CP113D 4.40

Incorporating the Logfile (2) / CP113E 4.41

CP113E stand alone with APS V17/CCNC CP113D on line with APS V11
MB/CCG(B), SN, CCNC

3-4 P30305-X1118-G503-01-7618
This page was left intentionally blank!

P30305-X1118-G503-01-7618 3-5
3.1.2. Phase 2: CP Change
Switching Switching network
i h

LTG SN-1

SN-0

LTG

Communication
interface

Phase 2:
- Disconnecting old cables
MB-1
- Connecting new cables
S
Y
MB-0 P
C

Central
control

Phase 2:
- Connection side 1 Phase 2:
IOPMB/CCG/SYP IOPMB/CCG/SYP
of periphery - Deactivation of
SN/MB/CCG/CCNP-1
and SYPC
CP113E - Disconnection of side 1 CP113D
of periphery
- Updating charge files

DEV D0

3-6 P30305-X1118-G503-01-7618
Phase 2: CP Change

To be started on upgrade day during low traffic hours

CP113E stand alone with APS CP113D on line with APS V11
V17/CCNC MB/CCG(B), SN, CCNC

Deactivation of SN/MB/CCG-1, SYPC / 5.1.1


CP113D

Disconnecting MB/CCG-1 and SYPC 5.1.2


from CP113D

Connecting MB/CCG-1 and SYPC to 5.1.3


CP113E

Check of MB(B) – IOPMB connection / 5.1.4


CP113E

Blocking Subscriber Controlled 5.2


Inputs/CP113E

Updating the Charge Files / CP113D 5.3

Deactivation of MDD-1 / CP113D 5.4

CP113E off line with APS V17/CCNC CP113D on line with APS V11
MB/CCG(B)-1,SN-1,CCNP-1 and SYP MB/CCG(B)-0, SN-0, CCNP-0

P30305-X1118-G503-01-7618 3-7
3.1.3. Phase 3: Cut Over
Switching Switching network
i h

LTG SN-1

SN-0

LTG

Communication
interface

Phase 3:
- Disconnecting old cables
MB-1
- Connecting new cables
S
Y
MB-0 P
C

Central
control

Phase 3:
- Connection side 0 Phase 3:
IOPMB/CCG/SYP IOPMB/CCG/SYP
of periphery - Ending switching
- Recov. ISTART2F operations
- System status - Disconnection of side 0
CP113E of periphery CP113D
check
- System test

DEV D0

3-8 P30305-X1118-G503-01-7618
Phase 3: Cut Over

System Interruption

CP113E off line with APS V17/CCNC CP113D on line with APS V11
MB/CCG(B)-1,SN-1,CCNP-1 and MB/CCG(B)-0, SN-0, CCNP-0
SYP

Stopping System CP113D APS V11 6.1

Disconnecting MB/CCG/CCNP-0 from 6.2.1


CP113D

Connecting MB/CCG/CCNP-0 and 6.2.2


SYPC to CP113E

Ending Installation Recovery / 6.3


CP113E

Startup of the CP113E System with 6.4


ISTART2F, APS V17/CCNC

Manual Startup of the CP113E 6.5


System APS V17/CCNC

System Status Inquiry / CP113E 6.6

Activating CAPs / CP113E 6.7

System Test APS V17/CCNC / 6.8


CP113E

CP113E on line with APS V17/CCNC CP113D stopped


MB/CCG(B), SN, CCNC

P30305-X1118-G503-01-7618 3-9
3.1.4. Phase 4: Post-Processing

Switching Switching network


i h

LTG SN-1

SN-0

LTG

Communication
interface

Phase 4:
All peripheral connections are cabled
to the CP113E MB-1
S
Y
MB-0 P
C

Central
control

Phase 4: Phase 4:
IOPMB/CCG/SYP IOPMB/CCG/SYP
- Incorporation last - Installation Recovery
logfile - Tape saving charge
- Meter regeneration and regeneration files
- Connection of links CP113E - Disconnection of links CP113D
- Diagnosis of - CP113D stopped
periphery
- Creating save APS
- CP113E online
DEV D0

3-10 P30305-X1118-G503-01-7618
Phase 4: Post-Processing

CP113E on line with APS V17/CCNC CP113D stopped


MB/CCG(B), SN, CCNC

Checking Charge Files / CP113E 7.1

Restoring original Charge Meter Saving 7.2


/ CP113E

Unblocking Subscriber Controlled 7.3


Inputs / CP113E

Updating the Database / CP113E 7.4

Disconnecting CSC-Links from CP113D 7.5.1

Connecting CSC-Links to the CP113E 7.5.2

Disconnecting X25-Links from CP113D 7.5.3

Connecting X25-Links to the CP113E 7.5.4

Activating Routine Tests 7.6

Starting Installation Recovery APS V11 / 7.7


CP113D

Starting Processes / CP113D 7.8

Unblocking Subscriber Controlled Imputs 7.9

File handling CP113D 7.10

Regeneration of Charge Meters / 7.11


CP113E

Stop Installation Recovery / CP113D 7.12

Diagnosis of the Periphery / CP113E 7.13

Deleting Command Files / CP113E 7.14

Removing the MP 7.15

Setting the Upgrade Option 7.16

Starting Jobs / CP113E 7.17

Saving APS V17/CCNC / CP113E 7.18

Casino Outage Report 7.19

CP113E on line with APS V17/CCNC CP113D stand alone and out of
MB/CCG(B), SN, CCNC service

End of procedure

P30305-X1118-G503-01-7618 3-11
This page was left intentionally blank!

3-12 P30305-X1118-G503-01-7618
4. PHASE 1: PREPARATION

4.1. Installation
• The installation part is not described in specific detail.
• See Chapter 12 for installation and cabling of new equipment.

4.1.1. Installation of CP113E

Install the new racks R:CP113E

Connection of MP:CP113E power cable to DCC of IOPG-1 in F:EIOP.


Connection of BAP-0 and BAP-1 to MP:CP113E.

IO P G – 1 M A IN T E N A N C E P A N E L
DCC

MP : C P113E

SELECT BAP 0: D Y D ...


U N IT BAP 1: D Y D ...
b lu e

re d

p o w e r s u p p ly fo r MP
B A P -0 B A P -1
B A P – 0 B A P – 1
P E X P E X

MP MP

218 256

P30305-X1118-G503-01-7618 4-1
4.1.2. Cabling of CP113E
Connecting cables CP113E - MB/CCG(B), cable group P, see Chapter 12.4.1

Prelay the new connecting cables between R:CP113E and the existing
R:MB/CCG(B) and R:MB(B):DE54 (in case of DE-type is DE54) of the CP113D
system:

Plug in the cables on the side R:CP113E only. At the MB(B) side the cables
have to be marked with a color code and positioned in such way that they can
be quickly inserted at a later stage according to system side 0 and 1.

Connecting cables CP113E - SYPC, cable group P, see Chapter 12.4.2

Prelay the new connecting cables between R:CP113E and the existing
R:MB/CCG(B) / SYPC of the CP113D system:

Plug in the cables on the side R:CP113E only. At the SYPC side the cables
have to be marked with a color code and positioned in such way that they can
be quickly inserted at a later stage.

Connecting cables CP113E - CCNC, cable group P, see Chapter 12.4.3

Prelay the new connecting cables between R:CP113E and the existing
R:CCNP of the CP113D system:

Plug in the cables on the side R:CP113E only. At the CCNP side the cables
have to be marked with a color code and positioned in such way that they can
be quickly inserted at a later stage according to system side 0 and 1.

Connecting cables CP113E - CSC / X25-links

Prelay the new connecting cables between R:CP113E and the existing
transmission equipment for the CSC- and X25-links of the CP113D system.

CSC / MODEM connection:


Plug in the cables on the side R:CP113E / IOPUNI-0,1 only.

X25 / MODEM connection:


Plug in the cables on the side R:CP113E / IOPLAU-x only.

At the other sides the cables have to be marked with a color code.

4-2 P30305-X1118-G503-01-7618
Connecting cables CP113E / IOPTA-0,1 - Radio clock DCF77 or GPS (if available)

Prelay the new connecting cables between R:CP113E and the existing radio
clock of the CP113D system:

Plug in the two cables on the side R:CP113E / IOPTA-0,1 only

Connecting cables CP113E/IOPTA - CCG(B), cable group P, see Chapter 12.4.1.1 and
Chapter 12.4.1.2 (only Clock-Cable) to IOPTA

Plug in the cables on the side R:CP113E / IOPTA-0, 1and R:MB/CCG(B).

CP113E 03C317 / P2 CCG-0 02B071 **


CP113E 04C317 / P2 CCG-0 02A071 ** *

CP113E 03C317 / P3 CCG-1 03B071 ** *


CP113E 04C317 / P3 CCG-1 03A071 **

* = Cross connecting cables


** = New clock cables

4.1.3. Cabling of CP113D

The old connecting cables between CP113D and MB(B), CCG, SYPC, CCNC
and transmission equipment and radio clock, have to be marked also with
color code on the side of the periphery, to prevent mistakes during cabling.

P30305-X1118-G503-01-7618 4-3
To be started one or two days before the upgrade

All preparatory operations which can be separated from the actual system upgrade process
are carried out in the following phase. This supports the smooth handling of the upgrade
procedure.

4.2. Establishing a Test Concept


After the successful startup of the new system with CP113E the switching equipment must be
carefully tested. As this test is exchange-specific, a suitable test method must be prepared by
the service staff involved.

The test includes for example:

Switching equipment

• Accessibility of emergency call numbers


• Accessibility of recorded announcements

• Outgoing traffic to the OMC or test telephones in neighboring exchanges:


o Test calls via each trunk group
o Test calls via each signaling type
o Test calls to international destinations (time announcement)

• Incoming traffic:
o External calls to test telephones
o Transit calls

• Comparison of faulty trunks/devices: before/after upgrade


• Comparison of faulty lines/subscribers: before/after upgrade

• Testing subscriber inputs


• Testing traffic restrictions

Charges

• Meter test, AMA


• Charge saving

Note:
The test concept has to be tested first with APS V11.

4-4 P30305-X1118-G503-01-7618
4.3. Transferring V11 Command and Patch Files to Disks / CP113D

CP113D

/ <STAT SSP;

! MOD-0 in ACT

Mount MO containing command and patch files in MOD-0

CP113D

/ <DISP FILE: FILE=CF.11.; Check if there are old files


<DISP FILE: FILE=PA.11.; ”

<DEL FILE: FILE=CF.11.; Delete old files if necessary


<DEL FILE: FILE=PA.11.; ”

<TRANS FILE: FILE=CF.11.,VSNS=<vsn>,MODE=CRD;


<TRANS FILE: FILE=PA.11.,VSNS=<vsn>,MODE=CRD;

Do not remove MO from MOD-0

4.4. Test of the CP113D


Test CP in low traffic periods.

CP113D

/ <STAT SSP;

! The CP113D must have full redundancy

CP113D

/ <EXEC CMDFILE:FILE=CF.11.CPTESTG503;

Failures detected during the tests have to be cleared according to


Maintenance Manual MMN:CP113 V11. The file HF.MCP.HWERROR has to be
scanned for sporadic hardware alarms during the last two weeks
(<SEL AENTRY:AFILE=HF.MCP.HWERROR,DATE=......)

<RSET MO:MOD=0;

Remove MO from MOD-0

P30305-X1118-G503-01-7618 4-5
4.5. Diagnosis of the Periphery / CP113D
The active devices MB/CCG(B), SN, SYPC and CCNC must be fault-free because the system
must run in phases without redundancy during the CP change. For this reason, these devices
have to be diagnosed and any detected faults cleared.

Diagnose periphery in a low traffic period.

4.5.1. Verification of MB / SN Capacity Stages


Note:
To be executed only, if the SN of capacity stage SN:252 LTG (DE52) or SN:504 LTG (DE54) is
only partially equipped.
Each first MBUL unit per MB frame serves apart from TSG connection also for the clock supply
of the respective MB group. This implies, that in partly equipped Switching Networks SN:DE52
or SN:DE54, MBUL’s may exist without TSG’s connected.
These MBUL’s must be in status ACT. If they are in PLA, they have to be configured to ACT.

CP113D

/ <DISP EXDDAT;

Visually check the TSGs in the current system:


SN:DE52 if TSG 0/1-2 exist
SN:DE54 if TSG 0/1-2, 0/1-4, 0/1-6 exist

Note:
Use rack and frame layouts in Chapter 12.3 for MB(B) to localize the MBULs concerned to the
not existing TSGs.

CP113D

/ <STAT SN;
<STAT MB;

! MBULs without TSGs are in ACT

4-6 P30305-X1118-G503-01-7618
Are the MBULs without TSGs in ACT?

YES: continue with Chapter 4.5.2

NO:

continue with Chapter 4.5.1.1

4.5.1.1. MBULs without TSGs are in PLA

CP113D

/ <CONF MBUL: MB=<0 and 1>, MBUL =<no>, OST=MBL; Configure all MBULs
<CONF MBUL: MB=<0 and 1>, MBUL =<no>, OST=ACT; without TSG to ACT

<STAT MB;
! MBULs without TSGs are in ACT

4.5.2. Diagnosis of the MB


The command file “CF.11.DIAGMB0G503 “ and “CF.11.DIAGMB1G503” for the diagnosis of
the MB-0 and MB-1 fit a system with capacity stage up to DE54. Each MB side is diagnosed
from CP-0 as well as from CP-1 by the following command file.

CP113D

/ <STAT MB;
<STAT SN;
<STAT CCNC: UNIT=MUXM-X;

! MB-0 and MB-1 in ACT Configure MB if necessary


SN-0 in ACT or STB, SN-1 in STB or ACT Configure SN if necessary
MUXM-0,1 and MUXM-10,11 in ACT or PLA Configure MUXM if necessary

P30305-X1118-G503-01-7618 4-7
CP113D

/ <EXEC CMDFILE: FILE=CF.11.DIAGMB0G503; Runtime about 10 min

! Please ignore error message if IOPMB is not created.


MB-0 in ACT, MB-1 in ACT

Wait 3 minutes for the synchronization of the SN

CP113D

/ <EXEC CMDFILE: FILE=CF.11.DIAGMB1G503; Runtime about 10 min

! Please ignore error message if IOPMB is not created.


MB-0 in ACT, MB-1 in ACT

Wait 3 minutes for the synchronization of the SN

4.5.3. Diagnosis of the SN


CP113D

/ <STAT SN;

! SN-0 in ACT or STB, SN-1 in STB or ACT

CP113D

/ <CONF SN:SN=<sn in stb>,OST= MBL; Configure SN in STB to MBL


<DIAG SN:SN=<sn in mbl>,TA=CHALL;
<CONF SN:SN=<sn in mbl>,OST=STB;

Wait 3 minutes for the synchronization of the SN

CP113D

/ <CONF SN:SN=<sn in act>,OST= STB;


<CONF SN:SN=<sn in stb>,OST= MBL;
<DIAG SN:SN=<sn in mbl>,TA=CHALL;
<CONF SN:SN=<sn in mbl>,OST= STB;

CP113D

/ <STAT SN;

! SN-0 in STB or ACT, SN-1 in ACT or STB

4-8 P30305-X1118-G503-01-7618
4.5.4. Check of the CCG - IOPMB Connection
Check if CCGs remain in status active, when configuring the corresponding IOPMBs.

CP113D

/ <STAT CCG;

! CCG-0 in ACT or STB, CCG-1 in STB or ACT

CP113D

/ <DISP CCG;

! Example:
STATUS AND ERROR INFORMATION: CCG-0 CCG-1
----------------------------+-----------+-----------
REF. FREQUENCIES AT CCGXXA : PRESENT PRESENT
OPERATING STATE : ACT STB or reverse
REFERENCE FREQUENCY 0 : GOOD GOOD
REFERENCE FREQUENCY 1 : GOOD GOOD
USED REFERENCE FREQUENCY : 0 1
SYNCHRONIZATION STATUS : SYNCHRON 4 SYNCHRON 4

CP113D

/ <CONF IOP: IOP=IOPMB-40, OST=MBL;

Wait 3 minutes if CCG-0,1 are still active

CP113D

/ <STAT CCG;
<CONF IOP: IOP=IOPMB-40, OST=ACT;
<CONF IOP: IOP=IOPMB-41, OST=MBL;

Wait 3 minutes if CCG-0,1 are still active

CP113D

/ <STAT CCG;
<CONF IOP: IOP=IOPMB-41, OST=ACT;

P30305-X1118-G503-01-7618 4-9
4.5.5. Check of the SYPC - IOPMB Connection
Check if SYP remains in status active, when configuring the corresponding IOPMBs.

CP113D

/ <STAT SYP;

! SYP in ACT

CP113D

/ <CONF IOP: IOP=IOPMB-42, OST=MBL;

Wait 3 minutes if SYP is still active

CP113D

/ <STAT SYP;
<CONF IOP: IOP=IOPMB-42, OST=ACT;
<CONF IOP: IOP=IOPMB-43, OST=MBL;

Wait 3 minutes if SYP is still active

CP113D

/ <STAT SYP;
<CONF IOP: IOP=IOPMB-43, OST=ACT;

4.5.6. Diagnosis of the CCNC


Each CCNP is diagnosed from CP-0 as well as from CP-1 by the following command file.

CP113D

/ <STAT CCNC:UNIT=CCNP-X;

! CCNP-0 in STB , CCNP-1 in ACT

CP113D

/ <CONF CCNC: UNIT= CCNP-1, OST= ACT; Configure CCNP-1 to ACT, if necessary

<EXEC CMDFILE: FILE=CF.11.DIAGCCNG503; Runtime about 30 min

Failures detected during the diagnosis have to be cleared according to


Maintenance Manual MMN:CCS7 V11

4-10 P30305-X1118-G503-01-7618
4.5.7. Checking the LTGs
Check if all created LTGs in the database are available physically, to prevent ev.
postprocessing faults of not available LTGs after system recovery.

CP113D

/ <DISP LTG:LTG=X-X;

<STAT LTG:LTG=X-X;

Compare created LTGs with available LTGs

CP113D

/ <CAN LTG:LTG=<ltg-no>; If created LTGs are not available

4.6. System Test / CP113D


The system test should be carried out in the CP113D corresponding to the test concept in
Section 4.2. After the startup with the CP113E, this test has to be repeated.

System test corresponding to the test concept in chapter 4.2

P30305-X1118-G503-01-7618 4-11
4.7. Saving of the actual APS V11 / CP113D

Save the current APS according to the procedure SW 210 in manual


MMN:SW 113 (quarterly saving) or use a project-specific command file

4.8. Saving of System Files / CP113D


All important system and command files have to be saved to MO.

Saving history files:

CP113D

/ <DISP FILE;

Save the history files by procedure SW:231 in manual MMN:SW or


project-specific command files:

HF.<files>
SG.<files>
TM.<files>
DC.<files>
AD.<files>
etc

Note:
If the history files are saved once more, they have to be released before with command
<REL CYCFILE:FILE=<file-name>;

Saving traffic measurement files TS., see manual OMN Chapter TR:

CP113D

/ <DISP TRAMORD: STATUS=ALL; Interrogate current measurement orders


<DISP TRAFICH; and files
<DISP FILE:FILE=TS.;
Active and accepted traffic measurement jobs are to be stopped and deleted,
see procedure TP-011

Terminated TS. files are to be saved to MO, see procedure TP-013

4-12 P30305-X1118-G503-01-7618
Saving traffic structure measurement file IA.ICTST, see manual OMN, Chapter TR:

CP113D

/ <DISP IAFEAT; Interrogate IA feature for traffic structure measurement TST


<DISP FILE:FILE=IA.; and files

Active traffic structure measurement is to be deactivated, see procedure


TS-050

File IA.ICTST is to be saved to MO, see procedure TP-056

Save CCS7 traffic structure measurement files T6., see manual OMN, Chapter TR:

CP113D

/ <DISP C7TRST;
<DISP FILE:FILE=T6.;

Active CCS7 traffic structure measurement is to be stopped and file


T6.TRST.<name> saved to MO, see procedure TP-065

Saving traffic observation measurement file IA.ICTOB, see manual OMN, Chapter TR:

CP113D

/ <DISP TOBS; Interrogate current measurement


<DISP IAFEAT; Interrogate IA feature for traffic observation measurement TOB
<DISP FILE:FILE=IA.; and files

Active traffic observation measurement is to be deactivated, see procedure


TS-031

File IA.ICTOB is to be saved to MO, see procedure TP-035

P30305-X1118-G503-01-7618 4-13
Saving directory number observation file IA.ICDNB, see manual OMN, Chapter TR:

CP113D

/ <DISP DNOBS; Interrogate current DN observation


<DISP IAFEAT; Interrogate IA feature for DN observation DNOB
<DISP FILE:FILE=IA.; and files

Active directory number observation is to be stopped and file IA.ICDNB is to


be saved to magnetic tape, see procedure TP-040

Command “CAN DNOBS“ is to be deleted in the actual logfile

Display of SCCP/TCAP monitoring data, if necessary:

CP113D

/ <DISP STMON;

Display of directory and service directory numbers with MOB.


The protocols of the MOB- and S130 MOB- subscribers are to be displayed for ev.
evaluation with the files IA.ICMOB and IA.ICFIR if saved later during the Upgrade
Procedure:

CP113D

/ <SEL MOBS;
<SEL SMOBS; S130 MOB
<DISP IAFEAT; Interrogate IA feature for meter observation MOB
<DISP FILE: FILE=IA.; and files

Saving security files SE./SA.ACTION, OP.ACTION and PW.LOG, if available:

CP113D

/ <DISP FILE;

Mount MO in MOD-0

CP113D

/ <INIT MO: VSN=<mo-no>, CD=EBC, MOD=0;


<TRANS FILE: FILE=<file-name>,VSNR=SECTAP; Save all security files available
<DISP FILE:VSN=<mo-no>;
<RSET MO:MOD=0;

Remove MO from MOD-0

4-14 P30305-X1118-G503-01-7618
Save all other project-specific command files, if necessary:

CP113D

/ <DISP FILE;

Mount MO in MOD-0

CP113D

/ <INIT MO: VSN=<mo-no>, CD=EBC, MOD=0;

<TRANS FILE: FILE=<file-names>,VSNR=<mo-no>,COPMOD=SSWF;

<DISP FILE: VSN=<mo-no>;

<RSET MO:MOD=0;

Remove MO from MOD-0

4.9. Preparation of APS V11 / CP113D


Stopping jobs:

CP113D

/ <DISP CFTJOB; Display running jobs


<DISP JOB; "
<STOP JOB:JN=<no>; Stop running jobs
<CAN JOB:JN=<no>, CMDCOD=EXECCMDFILE; Cancel jobs

Changing meter saving time.


So as not to disturb the saving of charge meters on MO, the time at which the charge meters
are saved automatically should be set in a non critical time frame. This command produces
an entry in the logfile which must be cancelled when the logfile is edited.

CP113D

/ <DISP METSAV;
<ENTR METSAV: TIME=<hr-min>, CHEKNO=0; If saving time is during
upgrade phase

P30305-X1118-G503-01-7618 4-15
To be started early on system upgrade day

4.10. Loading the APS V17/CCNC from MOD / CP113E


Prerequisites:
The completely installed APS V17/CCNC must be available on magneto optical disk MO and
the CP113E must be equipped with MOD.

Mount magneto optical disk MO with APS V17/CCNC into MOD-0

CP113E

Switch on power from BAP-0


Press BOOT key on CMYE-0

! As soon as the trackpoint A885 on the MP display disappears, the BOOT key
on CMYE-0 must be pressed.

! System messages:

IPL113: MANUAL START - CURRENT CONFIGURATION


UNIT STATUS MEMSIZE TEST
********************************************
BAP-0 MASTER xxxx MBYTE NO TEST RUN
BAP-1 UNA BAP-SPARE
etc.

IPL113: ENTER PARAMS


TO DIAGNOSE MEMORY : "HIST;"
TO DIAGNOSE MEMORY : "DIAG;"
TO FORMAT MEMORY : "FORMAT;"
TO CONTINUE : ";<ENTER>"

CP113E

FORMAT;

4-16 P30305-X1118-G503-01-7618
IPL113: MANUAL START - CURRENT CONFIGURATION
UNIT STATUS MEMSIZE TEST
****************************************************
BAP-0 MASTER xxxx MBYTE FORMAT CMY/BCMY OK
BAP-1 UNA BAP-SPARE
etc.

IPL113: ENTER PARAMS


TO DIAGNOSE MEMORY : "HIST;"
TO DIAGNOSE MEMORY : "DIAG;"
TO FORMAT MEMORY : "FORMAT;"
TO CONTINUE : ";<ENTER>"

CP113E

IPL113: MANUAL START ENTER PARAMS


TO START APS MANUALLY :"MANUALLY;"
TO START INSTALLAT.RECOV.:"INSTALLATION;"
TO START UTILITY(MONITOR):"UTILITY;"
TO STOP INITIAL START :"STOP;"
TO START APS AUTOMATICALLY:;"<ENTER>"

CP113E

UTI;

UTILITY-RECOVERY - DEVICE-TYPE TO USE : "MDD;/MTD;/MOD;"

CP113E

MOD;

UTILITY RECOVERY - LOAD FROM IOC/IOP/DEVICE-NO (HEX):

CP113E

010C23 (MOD-0, CP113E)

PLEASE ENTER UTILITY-FILE-NAME

CP113E

SY.INSTALL Without semicolon

IMON (xxxxxxxxxxxx) STARTED


IMON: ENTER COMMAND

CP113E

<LABELMD

IMON: COMMAND LABELMD ENTER OPERAND:DEVOUT=

P30305-X1118-G503-01-7618 4-17
CP113E

<030C01 (MDD-1)

IMON: COMMAND LABELMD EXECUTED


IMON: ENTER COMMAND

CP113E

Switch off power from MDD-1

CP113E

<LABELMD

IMON: COMMAND LABELMD ENTER OPERAND:DEVOUT=

CP113E

<010C01 MDD-0, CP113E

IMON: COMMAND LABELMD EXECUTED


IMON: ENTER COMMAND

CP113E

<DISPMDDIR

IMON: COMMAND DISPMDDIR ENTER OPERAND:DEVIN=

CP113E

<010C01 (MDD-0)

VOLIN : DIR FOR MDD 010C01


FILENAME GEN SIZE TYPE FILEFLAG
--------------------------------------------------------------------
SY.SLRAM xxxxxxxx xxxxxxxx PAM xxxx
SY.TRANSLOG xxxxxxxx xxxxxxxx PAM xxxx
--------------------------------------------------------------------
FREE SECTORS ON DISK :xxxxxxxx
IMON: ENTER COMMAND

CP113E

<TRANSFILE

IMON: COMMAND TRANSFILE ENTER OPERAND:DEVIN=

CP113E

<010C23 (MOD-0)

IMON: COMMAND TRANSFILE ENTER OPERAND:DEVOUT=

4-18 P30305-X1118-G503-01-7618
CP113E

<010C01 (MDD-0)

IMON: COMMAND TRANSFILE ENTER OPERAND:FILECAT=

CP113E

<*

IMON: COMMAND TRANSFILE ENTER OPERAND:OLDGEN=

CP113E

<*

IMON: COMMAND TRANSFILE ENTER OPERAND:NEWGEN=

CP113E

<*

TRANS: FILE SY.GENLIST GEN 00000000 COPIED TO FILE


SY.GENLIST GEN 00000000
TRANS: FILE SY.INSTALL GEN 00000000 COPIED TO FILE
SY.INSTALL GEN 00000000
etc

TRANS: ADDITIONAL TAPE / MOD ? (Y/N)

! If the APS V17 is available on more then one MO, the following message is output:
TRANS:PLEASE MOUNT CONTINUATION MOD <mo-no> AND PRESS ENTER

Remove first MO with APS V17 from MOD-0 of CP113E


Mount second MO with APS V17 in MOD-0 of CP113E

CP113E

<ENTER>

TRANS: FILE SY.SEMILIB GEN 00000000 COPIED TO FILE


SY.SEMILIB GEN 00000000
etc.

TRANS: ADDITIONAL TAPE / MOD ? (Y/N)

! If the last MO was loaded, enter “N”:

P30305-X1118-G503-01-7618 4-19
CP113E

<N

IMON: COMMAND TRANSFILE EXECUTED


IMON: ENTER COMMAND

CP113E

<DISPMDDIR

IMON: COMMAND DISPMDDIR ENTER OPERAND:DEVIN=


CP113E

<010C01 MDD-0, CP113E

VOLIN : DIR FOR MDD 010C01


etc.

! The following system files must have been transferred to disk MDD-0:
SY.GENLIST List ofGeneration
SY.INSTALL Installation monitor
SY.TASKLIB CP software (resident part)
SY.LOADLIB.CA Library for reloadable commands
SY.LOADLIB.LA Library for reloadable (non-resident) processes
SY.LOADLIB.MA Library for reloadable masks
SY.PSW.Txxx Txxx=LTG, CCNC and IOP:UNI load types
SY.SEMILIB Library for semipermanent data
SY.SIMP CCNC SIMP:SW database
SY.UPLOG Library for update of SY.SEMILIB
SY.VSD.BACKUP Library for VSD database
SY.MSGXREF Reference list of messages

Remove last MO from MOD-0 of CP113E

4-20 P30305-X1118-G503-01-7618
4.11. Installation Recovery with complete APS V17/CCNC CP113E

CP113E

Switch off power from BAP-1 If not yet switched off

Switch off power from MDD-1 If not yet switched off

Press BOOT key on CMYE-0

! Should the track point A885 be exceeded, the BOOT-Key must be pressed again
until track point A885 is reached and the IPL-Menu is displayed on OMT-0.

! System messages:

IPL113: MANUAL START - CURRENT CONFIGURATION


UNIT STATUS MEMSIZE TEST
********************************************
BAP-0 MASTER xxxx MBYTE NO TEST RUN
BAP-1 UNA BAP-SPARE
etc.

IPL113: ENTER PARAMS


TO DIAGNOSE MEMORY : "HIST;"
TO DIAGNOSE MEMORY : "DIAG;"
TO FORMAT MEMORY : "FORMAT;"
TO CONTINUE : ";<ENTER>"

CP113E

FORMAT;

IPL113: MANUAL START - CURRENT CONFIGURATION


UNIT STATUS MEMSIZE TEST
*****************************************************
BAP-0 MASTER xxxx MBYTE FORMAT CMY/BAMY OK
BAP-1 UNA BAP-SPARE
etc.

IPL113: ENTER PARAMS


TO DIAGNOSE MEMORY : "HIST;"
TO DIAGNOSE MEMORY : "DIAG;"
TO FORMAT MEMORY : "FORMAT;"
TO CONTINUE : ";<ENTER>"

CP113E

P30305-X1118-G503-01-7618 4-21
IPL113: MANUAL START ENTER PARAMS
TO START APS MANUALLY :"MANUALLY;"
TO START INSTALLAT.RECOV.:"INSTALLATION;"
TO START UTILITY(MONITOR):"UTILITY;"
TO STOP INITIAL START :"STOP;"
TO START APS AUTOMATICALLY:";ETX"

CP113E

INS;

IOC-0 MDD : BZS/AKD :


xxxxxxxxxxxxxx

IOC-0 MDD : GENERATION-LIST:


17xxxx xxxxxxxxxxxxxxxxxxxxxxxx

INSTALLATION RECOV.-LOADING VIA IOC : "IOC-0;/IOC-1;"

CP113E

IOC-0;

LOAD.DEV.=*MDD0* -GENERATION TO LOAD :"NAME;"(8 CHAR)

CP113E

17xxxxx;

##### BAP-0 IS LOADING APS - DISPLAY : AB05 #####

After approx. 2 minutes, the following system message is output and the display on IOPTA-0
shows status “AC”:

! After the system message “INSTALL RECOVERY - INFORMATION ...“ or when the
display on IOPTA-0 changes to “AC“, the APS can be started as follows:

4-22 P30305-X1118-G503-01-7618
The APS V17 can be started now in the following way:

OMT-SW: XENIX OMT-SW: UNIX

CP113E CP113E

/ Press the request key F1 / <START FCP;

PLEASE ENTER USERID PLEASE ENTER USERID


<userid> <userid>

PLEASE ENTER CURRENT PLEASE ENTER CURRENT


PASSWORD PASSWORD
<password> <password>

CP113E

/ <START FCP;

Message: STARTFCP EXEC´D

CP113E

/ <START OM; Process is not executed, restart the Installation Recovery

<START SFGSW;

<START CSWD;

<DISP TIME; Time is secure

If time is insecure, enter time and date and set to secure:

CP113E

/ <ENTR TIME:DATE=<yy-mm-dd>, TIME=<hh-mm-ss>, WD=<wd>,


OFFSET=<x> - POS or NEG, SEASON=<zzz>;

<x>= 0....840, number of OFFSET minutes decimal (multiple of 15).


OFFSET is the time difference between Universal Time Clock
(UTC) and local time.
POSitive or NEGative is the OFFSET direction
<zzz>= STD Standard or
<zzz>= DST Daylight saving

CP113E

/ <MOD TIME:MODE=SECURE;

P30305-X1118-G503-01-7618 4-23
Check the new generation files for correct transmission between load device and MDD
This is done by starting the checksum audit, which compares IMON- and MDD-checksums:

CP113E

/ <ACT MDDAUDIT:TYPE=X;

! The checksums of all generation files must be OK.


In case of checksum errors, check the transmission path (MOD, IOPs, MDD,
cabling) and repeat APS loading

Check of Q3 feature.
If Q3 is required, the parameter “Q3ACTIVE“ must be YES:

CP113E

<DISP EXDDAT;
<ENTR EXDDAT: Q3ACTIVE=YES; If required YES / NO

Check of meter types.


The types METSTAT and METTR are not used, because from V10 on, the IACHASTA
registration exists. If necessary, the meter type in parameter “MET“ has to be changed.

CP113E

<DISP EXDDAT;
<ENTR EXDDAT:MET=<met-type>; If required

Check of memory sizes.


The memory sizes, especially the size of the CMY, has to be checked. If necessary, the
parameter “CMYSIZE“ has to be changed.

CP113E

<DISP EXDDAT;

<DISP SSP;

! For example:
UNIT PBI MEMSIZE FIRMWARE VERSIONS DATA
PHYS APS
B-PART APS PART APS PART UP-TO-
(FE)PROM FRPROM IN APS DATE
-----------------------------------------------------------------
BAP-0 0 64 64 YES
BAP-1 2 64 NO
CAP-0 4 32 NO
IOC-0 1 32 YES
IOC-1 3 32 YES
CMY-0 512 512 YES
CMY-1 512 512 YES

4-24 P30305-X1118-G503-01-7618
CP113E

<ENTR EXDDAT: CMYSIZE=<cmy-size>; If required, change cmy-size to the value of the


APS mem-size

<DISP EXDDAT;

Check split options

<DISP SPLITOPT; Split option must be reset


<RSET SPLITOPT; If split option is set

Attention:
If the Installation Recovery is exited and the processor changes to STOP, a message is output
indicating that the Installation Recovery must be restarted using the commands above:

*** ERRORS (SWSG, ALARM) DURING INSTALLATION RECOVERY ***


*** NEW INSTALLATION RECOVERY NECESSARY ***

P30305-X1118-G503-01-7618 4-25
4.12. Checking the Validation of the new Generation CP113E
CP113E

/ <DISP GEN;

<MOD GEN: GEN=<generation>,VALIDITY=VALID; If generation "NOT VALID"


<ACT GEN:GEN=<generation>; If generation is "BLOCKED"
<MOD GEN:GEN=<generation>VALIDITY=BLOCKED; Not actual generations

4.13. Deactivation of Routine Tests

4.13.1. Deactivation of Routine Tests CP113D/V11


CP113D

/ <INHIB SSPRT;

4.13.2. Deactivation of Routine Tests CP113E/V17/CCNC


CP113E

/ <INHIB SSPRT;

4.14. Transferring V17/CCNC Command Files to Disks CP113E

Mount MO containing V17 command files in MOD-0 of CP113E

CP113E

/ <STAT SSP; MOD-0 in ACT

<TRANS FILE: FILE=CF.17., VSNS=<vsn>, MODE=CRD;


<RSET MO: MOD=0;

Remove MO from MOD-0

4-26 P30305-X1118-G503-01-7618
4.15. Activation of BAP-1 CP113E

Switch on power to BAP-1 of CP113E

CP113E

/ <CONF BAP:BAP=1,OST=MBL;
<DIAG BAP:BAP=1;
<CONF BAP:BAP=1,OST=SPR;

4.16. Activation of MDD-1 CP113E

Switch on power to MDD-1 of CP113E Wait 30 sec. for the runup of the MDD

CP113E

/ <MOD MDDAUDIT:LOCKSTAT=UNLOCKED;
<CONF MDD:MDD=1,OST=MBL;
<DIAG MDD:MDD=1;
<CONF MDD:MDD=1,OST=ACT;

! Supervise the message “SYNCHRONIZING FROM MDD-0 TO MDD-1: FINISHED“,


but continue executing the procedure

4.17. Activating IOPMBs CP113E


Command file CF.17.ACTIOPG503 activates all IOPMBs up to stage DE54.

CP113E

/ <EXEC CMDFILE:FILE=CF.17.ACTIOPG503;

! Ignore error message for not created IOPMBs.


Available IOPMBs in ACT, if not configure manually

P30305-X1118-G503-01-7618 4-27
4.18. Activation of CAPs CP113E
The command file CF.17.ACTCAPG503 fits a system with CAP-0 up to CAP-5 and configures
all available CAPs.

CP113E

/ <EXEC CMDFILE:FILE=CF.17.ACTCAPG503;

! Please ignore error messages if the corresponding CAP is not available.


All available CAPs in ACT

4.19. Check Creation of CSC-Links CP113E


Check if the CSC-links are created in the IOPUNI-0,1, corresponding to the CP113D.

CP113E

/ <DISP CSC:CSC=X;
<DISP IOP:IOP=IOPUNI-0;
<DISP IOP:IOP=IOPUNI-1;
<STAT SSP;

! CSC-links are created

For example:
UNIT IOP CHANNEL BAUDRATE ADDR CONN. INTERFACE
CSC-x IOPUNI-x x 9600 x MODEM V24

4.20. Check Creation of X25-Links CP113E


Check if the X25-links are created in the IOPLAU-x, corresponding to the CP113D.

CP113E
/ <DISP IOP:IOP=IOPLAU-0;
<DISP IOP:IOP=IOPLAU-1;
<DISP IOP:IOP=IOPLAU-2;
<DISP IOP:IOP=IOPLAU-3;
<DISP X25LINK:X25LINK=X;
<STAT SSP;

! IOPLAU/LAU 0 up to 3 are created, X25-links are available


IOPLAU-0,1, BIOC=11, IOPLAU-2,3 BIOC=15

4-28 P30305-X1118-G503-01-7618
4.21. Configuration of links CP113E
Command file CF.17.PLACSCG503 configures CSC-link CSC-0 up to CSC-3 to PLA.
Command file CF.17.PLAX25G503 configures X25LINK-0 up to X25LINK-7 to PLA.

CP113E

/ <EXEC CMDFILE:FILE=CF.17.PLACSCG503;
<EXEC CMDFILE:FILE=CF.17.PLAX25G503;

4.22. Test of the CP113E


CP113E

/ <STAT SSP;

! Required states of the CP113E:


BAP-0 = MAS oder SPR BAP-1 = SPR oder MAS
CAP-0...5 = ACT (If available)
IOC-0 = ACT IOC-1 = ACT
CMY-0 = ACT CMY-1 = ACT
BCMY-0 = ACT BCMY-1 = ACT
IOPMB-0 = ACT IOPMB-1 = ACT (CCNC)
IOPMB-32 = ACT IOPMB-33 = ACT (DE4 -DE54)
IOPMB-34 = ACT IOPMB-35 = ACT (DE52,DE54)
IOPMB-36 = ACT IOPMB-37 = ACT (DE54)
IOPMB-40 = ACT IOPMB-41 = ACT (CCG)
IOPMB-42 = ACT IOPMB-43 = ACT (SYP)
IOPUNI-0 = ACT IOPUNI-1 = ACT
IOPTA-0 = ACT IOPTA-1 = ACT
IOPLAU-0 = ACT IOPLAU-1 = ACT (X25LINK)
IOPLAU-2 = ACT IOPLAU-3 = ACT “
LAU-0 = ACT LAU-1 = ACT “
LAU-2 = ACT LAU-3 = ACT “
MDD-0 = ACT MDD-1 = ACT
MOD-0 = ACT MOD-1 = ACT (If available)
OMT-0 = ACT OMT-1 = ACT
CSC-0 = PLA CSC-1 = PLA (If available)
X25LINK-0 = PLA X25LINK-1 = PLA (If available)

Test of the CP:

Mount MO in MOD-0 of CP113E Necessary for the CP test

CP113E

/ <TEST SSP;
<RSET MO: MOD=0;

Remove MO from MOD-0

P30305-X1118-G503-01-7618 4-29
4.23. Creating and Checking Files CP113E

4.23.1. Starting Processes


In the Installation Recovery mode not all processes for logfile incorporation and creation of
charge files are started. For this reason the following processes are to be started by command
file CF.17.PROG503:

CP113E

<EXEC CMDFILE: FILE=CF.17.PROG503;

<DISP METSAV;

! Wait for command execution before continuing. If command is executed all


processes are started

Note:
See following chapters for output of system messages during start of the processes.

4.23.2. Checking and Creating CA Files


If no CA files are available, the following message is displayed on the OMT-0 during start of the
processes:

CHARGING SAFEGUARDING MESSAGE

CAUTION: AN APS GENERATION CHANGE HAS BEEN DETECTED BY THE


CHARGING SAFEGUARDING. FOR THE DURATION OF THE
DATA BASE SYNCHRONIZATION, CHARGING SAFEGUARDING
ACTIONS ARE INHIBITED.
MANUAL ACTIVATION OF THE CHARGING FALLBACK ACTIONS
(”SAVE MET FUNC=FALLBACK”) IS REQUIRED FOR THE
FOLLOWING CHARGING TYPE(S)
SUBSCRIBER CHARGING
TOLL FREE SERVICE CHARGING
etc

4-30 P30305-X1118-G503-01-7618
Checking CA-files

CP113E

/ <DISP EXDDAT; Interrogation of MET types


<DISP FILE: FILE=CA.; and CA charge files

! Normally no CA files are available

Creating CA-file if necessary


If CA files are not available, enter the corresponding ”SAVE MET:TYPE..” command for
each existing meter type. If this command will be rejected with the message:

”MML-COMMAND NOT ALLOWED IN ACTUAL STATE”

then first enter command ”

<SAVE MET: FUNC= FALLBACK;”

CP113E

/ <SAVE MET:TYPE=METSUB,ZEROIN=Y,FUNC=FALLBACK; Meter type, see V11


<SAVE MET:TYPE=<all other types>,ZEROIN=Y,FUNC=FALLBACK;

<DISP FILE: FILE=CA.;

! CA files available

4.23.3. Checking and Creating IA Files


If no IA files are available, the following message is displayed on the OMT-0 during start of the
processes and creation of the IA files, when the corresponding IA feature is already activated in
APS V17/CCNC:

INDIVIDUAL CALL DATA


FILE IA.Icxxx WAS LOST AND CREATED AGAIN

Checking IA-files

CP113E

/ <DISP IAFEAT; Interrogation of IA features


<DISP FILE: FILE=IA.; and IA files

! IA files available

P30305-X1118-G503-01-7618 4-31
Creating IA-file if necessary
If IA files are not available, enter the corresponding ”ACT IAFEAT..” command:

CP113E

/ <ACT IAFEAT:TYPE=AMA,SIZE=<size>; IA feature and <size> , see old APS


<ACT IAFEAT:TYPE=DNOB,SIZE=<size>; ”
<ACT IAFEAT:TYPE=ERS,SIZE=<size>; ”
<ACT IAFEAT:TYPE=FIR,SIZE=<size>; ”
<ACT IAFEAT:TYPE=IARA,SIZE=<size>; ”
<ACT IAFEAT:TYPE=INA,SIZE=<size>; ”
<ACT IAFEAT:TYPE=MAL,SIZE=<size>; ”
<ACT IAFEAT:TYPE=MOB,SIZE=<size>; ”
<ACT IAFEAT:TYPE=TOB,SIZE=<size>; ”
<ACT IAFEAT:TYPE=TST,SIZE=<size>; ”
<ACT IAFEAT:TYPE=<type>,SIZE=<size>; ”

<DISP FILE: FILE=IA.;

! IA files available

4.23.4. Checking and Craeting IACHASTA Registration


IACHASTA-Metering
Registration of summation data link call number or call duration and storing on meters
separately for each traffic relation (new files CA.IC.UCHA and CA.IR.rnnns.fffff).

IACHASTA-AMA
Grouping the call data individually for each call and generating a AMA data record (new file
IA.ICIAR).

The IACHASTA registration has to be created and activated exchange-specific.

The registration of subscriber meters as well as toll free meters will be continued.

Example for start of IACHASTA registration for MET, if necessary:

Stored in file CA.IC.UCHA and CA.IR.rnnns.fffff.

CP113E

/ <DISP IACRG; Display of MET registration status


<ACT IACRG: OUT=MET, RGPTTYPE=<x>; If counting not started,
x=SINGLE / DOUBLE / MIXED
<DISP IACRG; MET registration active

4-32 P30305-X1118-G503-01-7618
Example for start of IACHASTA registration for AMA, if necessary:

Registerd in records and stored in file IA.ICIAR.

CP113E

/ <DISP IACRG; Display of AMA registration status


<DISP IAFEAT; Display of IA-feature
<ACT IAFEAT:TYPE=IARA,SIZE=<size>; If necessary
<ACT IACRG: OUT=AMA; If counting not started
<DISP IACRG; AMA registration active

4.23.5. Checking Security Files


CP113E

/ <DISP FILE:FILE=SE.;
<DISP FILE:FILE=SA.;
<DISP FILE:FILE=SJ.;
<DISP FILE:FILE=OP.;
<DISP FILE:FILE=PW.;

! Security files available if used

4.24. Changing Meter Saving Time / CP113E


The time at which the charge meters are saved automatically should be set out of the upgrade
phase.

CP113E

/ <DISP METSAV;
<ENTR METSAV:TIME=<hour-min>,CHEKNO=0;

4.25. Checking Data for Meter Administration CP113D / CP113E


CP113D

/ <DISP METADM;

CP113E

/ <DISP METADM;

! Compare meter administration data of V11 and V17/CCNC.

P30305-X1118-G503-01-7618 4-33
4.26. Handling of ALIAS Names

4.26.1. Checking ALIAS Names


CP113D
/ <DISP ALIAS: ALIAS=X;

4.26.2. Incorporating ALIAS Names


Input ALIAS names in V17/CCNC if available in V11.

CP113E

/ <ENTR ALIAS: FILE=<file-name>, ALIAS=<alias-name>;

4.27. Processing Logfile (1) / CP113D


All log files since the database retrieval in V11 (REGEN and display data = database for
the V17/CCNC load- MO) must be processed and saved.

General notes for logfile processing:

Conversion of LG-log files from APS V11 to the new command syntax of APS V17/CCNC.
See procedure description ”Database Handling V9…V17 to V17” /2/.

The following steps have to be done:

• Switching the log function

• Copying the original log file

• Transferring log file LG.<name>.A1 to MO for database conversion on PC

• Transferring log file LQ.<name>.A1 to MO for incorporation in V17/CCNC if Q3 feature is


active

• Conversion of the LG-log file using PC with tools TACO /6/, WinDISKUS /8/ and
REFORM /7/

• Incorporation of the converted LG-log file and the unconverted LQ-log file in V17/CCNC

4-34 P30305-X1118-G503-01-7618
4.27.1. Checking for Security Keywords
Executing REGEN run on subsystem FA:

CP113D

/ <DACT FNS: FNS=RG;


<EXEC REGEN: FUNC=FA, VSN=SYSVSN, LANG=<lang>, SIZE=24;

Attention: If the APS syntax is in English, the parameter “LANG“ must be NAT.
For all other syntaxes, the parameter “LANG“ must be ENG.

<ACT FNS: FNS=RG;

Check if the file RG.FA.<exchid> contains Security Keywords:

CP113D

/ <DISP FILE:FILE=RG.;

<EXEC EDTS8;

*R RG.FA.<exchid>
*P& “SECURE=Y“
*D&
*END

Attention: If Security Keywords have been found in the APS, the file
RG.FA.<exchid> has to be saved to tape.

Saving the regenerated RG.FA.<exchid> to tape for reformation on PC:

Mount MO in MOD-0

CP113D

/ <INIT MO: VSN=<vsn>, CD=EBC, MOD=0;

<TRANS FILE:FILE=RG.FA.<exchid>, VSNR==<vsn>,COPMOD=SSWF;

<DISP FILE: VSN==<vsn>;

<RSET MO:MOD=0;

Remove MO from MOD-0

Continue with checking the logfile. For further processing of the file
RG.FA.<exchid>, see procedure ”Database Handling V9….V17 to V17” /2/.

P30305-X1118-G503-01-7618 4-35
4.27.2. Checking the Logfile
Switching the LOG function:

CP113D

/ <DISP FILE: FILE=LG.; Interrogation of logfiles


<STAT LOG; LOG state is on
<MOD LOGFILE: FILE=<file-name>; Close current logfile and open new logfile
<DISP FILE: FILE=LG.; Interrogation of logfiles

Copying the terminated original logfile:

CP113D

/ <EXEC EDTS8; For reasons of safety, the logfile


*R LG.<name>.A1 should be stored under another name
*W LOG1 before reformatting, e.g. LOG1

Check logfile for syntax conversion:

Check logfile if conversion on OMT in EDTS8 is possible or conversion on PC


is necessary

CP113D

/ *W LG.<name>.A1
*Y
*D&
*END

4-36 P30305-X1118-G503-01-7618
4.27.3. Saving and Converting Logfile (1) / Dest. APS V17/CCNC
The LG-logfile (1) is saved on MO and converted on PC/Laptop, the LQ-logfile (1) is saved on
MO for incorporation in APS V17/CCNC:

Save the LQ-logfile (1), if Q3 is active:

Mount MO in MOD-0

CP113D

/ <INIT MO: VSN=<mo-no>,MOD=0,CD=EBC;

<DACT FNS: FNS=LQ;


<TRANS FILE: FILE=LQ.<logfile-name>.A1,VSNR=<mo-no>,
COPMOD=SSWF;

<DISP FILE: VSN=<mo-no>;

<RSET MO:MOD=0;

Remove MO from MOD-0 and hold it ready for incorporation of the LQ-logfile
in APS V17/CCNC

Save the LG-logfile (1):

Mount MO in MOD-0

CP113D

/ <INIT MO: VSN=<mo-no>,MOD=0,CD=EBC;

<DACT FNS: FNS=LG;


<TRANS FILE: FILE=LG.<logfile-name>.A1,VSNR=<mo-no>,
COPMOD=SSWF;

<DISP FILE: VSN=<mo-no>;

<ACT FNS: FNS=X;

<RSET MO:MOD=0;

Remove MO with LG-logfile from MOD-0

Convert the LG-logfile (1) from V11 to V17/CCNC syntax, corresponding to


procedure ”Database Handling V9….V17 to V17” /2/

P30305-X1118-G503-01-7618 4-37
4.28. Switch over of CCNP-1 from CP113D to CP113E

4.28.1. Deactivation of CCNP-1 in V11

CP113D

/ <STAT CCNC: UNIT=CCNP-X;

! CCNP-0 in ACT, CCNP-1 in STB Configure CCNP-0 to ACT if necessary

CP113D

/ <CONF CCNC: UNIT=CCNP-0, OST=ACT;


<CONF CCNC: UNIT=CCNP-1, OST=MBL;

4.28.2. Disconnection of CCNP-1 from CP113D

See Chapter 12.4.3.1 for connecting cables R:CP113D, IOPMB-0,1 - R:CCNP, CCNP-1.

Unplug cables (from CP113D) on side CCNP-1

CP113D

/ <STAT CCNC: UNIT=CCNP-X;

! CCNP-0 in ACT/ACT, CCNP-1 in MBL/MBL,

4.28.3. Connection of CCNP-1 to CP113E

See Chapter 12.4.3.1 for connecting cables R:CP113E, IOPMB-0,1 - R:CCNP, CCNP-1.
CP113E

Plug in cables (from CP113E) on side CCNP-1

4.28.4. Activation of CCNP-1 in V17/CCNC

The activation of CCNP-1 is necessary for the incorporation of No.7 commands, which may
exist in the log files.

CP113E

/ <STAT SSP;

! IOPMB-0,1 in ACT

4-38 P30305-X1118-G503-01-7618
CP113E

/ <STAT CCNC: UNIT=CCNP-X;

! CCNP-0 in UNA/UNA, CCNP-1 in UNA/UNA

CP113E

/ <CONF CCNC: UNIT=CCNP-0, OST=MBL;


<CONF CCNC: UNIT=CCNP-1, OST=MBL;
<CONF CCNC: UNIT=CCNP-1, OST=ACT;
<CONF CCNC: UNIT=CCNP-0, OST=STB; PART’LY EXEC´D

<STAT CCNC: UNIT=CCNP-X;


! CCNP-0 in STB/NAC, CCNP-1 in ACT/ACT

4.29. Incorporating the Logfile (1) / CP113E


LG-logfile (1) and LQ-logfile (1) available since last database retrieval must be incorporated.

CP113E

/ <STAT LOG; LOG-function is OFF


<RSET LOG; If LOG-function is ON

<DISP EXDDAT; Q3ACTIVE is YES or NO

<DACT FNS: FNS=LG;


<DACT FNS: FNS=LQ; If Q3 is active

Load LG-logfile (1), LQ-logfile (1) and the masterlogfile from the database conversion:

Mount MO containing with the converted LG-logfile (1), the unconverted


LQ-logfile (1) and the master logfile in MOD-0

CP113E

/ <TRANS FILE: FILE= LG.17., VSNS=<mo-no>, MODE=CRD;


<TRANS FILE: FILE= LQ.17.LOGx/LQ.LOGx.A1,VSNS=<mo-no>,
MODE=CRD;
<DISP FILE: FILE=LG.;
<DISP FILE: FILE=LQ.;

Logfiles LG.17.LOGx, LG.17.MFx and LQ.17.LOGx available

<RSET MO:MOD=0;

Remove MO from MOD-0

P30305-X1118-G503-01-7618 4-39
Incorporate LG-logfile (1) and if Q3 is active the LQ-logfile (1):

CP113E

/ <EXEC CMDFILE: FILE=LG.17.LOGx, CHOL=Y; Syntax check for each LG-logfile

<ACT IAOPT:BLBUFR=ADMREC; Suppression of AMA-Tickets

<DISP FILE:FILE=CA.; No CA files with extension .REL or


.NEW available, if not, wait until
these files are deleted autom.
”Metering critical commands are
allowed again”

<EXEC CMDFILE: FILE=LG.17.MFx; For each LG-logfile. If available the


corresponding LQ-logfile is started
autom. from the LG-logfile

CP113E

/ <ACT FNS: FNS=LG;


<ACT FNS: FNS=LQ; If Q3 is active

<CANIAOPT:BLBUFR=ADMREC;

4-40 P30305-X1118-G503-01-7618
4.30. Checking System Availability of APS V11 / CP113D
CP113D

/ <EXEC CMDFILE: FILE=CF.11.SYSTATG503;

! Required file states:


Update status is NORMAL
LOG state is ON
All double files are available on both disks
All files for activated charge, IA and IR features are available

! Required CP states:
BAP-0 = MAS or SPR BAP-1 = SPR or MAS
CAP-0...5 = ACT (If available)
IOC-0 = ACT IOC-1 = ACT
IOC-2 = ACT IOC-3 = ACT (DE54)
CMY-0 = ACT CMY-1 = ACT
BCMY-0 = ACT BCMY-1 = ACT
IOPMB-0 = ACT IOPMB-1 = ACT (CCNC)
IOPMB-32 = ACT IOPMB-33 = ACT (MB:DE4,51,52,54)
IOPMB-34 = ACT IOPMB-35 = ACT (MB:DE52,54)
IOPMB-36 = ACT IOPMB-37 = ACT (MB:DE54)
IOPMB-38 = ACT IOPMB-39 = ACT (MB:DE54)
IOPMB-40 = ACT IOPMB-41 = ACT (CCG)
IOPMB-42 = ACT IOPMB-43 = ACT (SYP)
IOPMDD-0 = ACT IOPMDD-1 = ACT
IOPSCDV-0 = ACT IOPSCDV-1 = ACT
IOPTA-0 = ACT IOPTA-1 = ACT
IOPLAU-0 = ACT IOPLAU-1 = ACT (X25LINK)
IOPUNI-0 = ACT IOPUNI-1 = ACT (if available)
MDD-0 = ACT MDD-1 = ACT
MOD-0 = ACT MOD-1 =*MBL/ACT (If available)
OMT-0 = ACT OMT-1 = ACT (If available)
LAU-0 = ACT LAU-1 = ACT (X25LINK)
CSC-0 = ACT CSC-1 = ACT (If available)
X25LINK-0 = ACT X25LINK-1 = ACT (If available)

! Required states of peripheral units:


MB: MB-0 in ACT, MB-1 in ACT
SN: SN-0 in ACT/STB, SN-1 in STB/ACT
CCG: CCG-0 in ACT/STB, CCG-1 in STB/ACT
SYP: ACT
CCNC: CCNP-0 in ACT/ACT, CCNP-1 in MBL/MBL
LTG: LTG 0-1 through 0-63 in ACT, CH0/CH1 in ACT or STB
LTG 1-1 through 1-63 in ACT, CH0/CH1 in ACT or STB
etc
DLU: DLUC-0,1 in ACT

If the current operating conditions differ from those shown above,


appropriate configurations must be made

P30305-X1118-G503-01-7618 4-41
CP113D

/ <DISP ALARM;

! System fully diagnosed without faults and alarms

4.31. Checking the LTG States CP113D / CP113E


All LTGs with status ACT in the APS V11 must have status PLA (H’07’) in the APS V17/CCNC.
All LTGs with status MBL in the APS V11, which should not loaded with the recovery APS
V17/CCNC must be switched power off (the configuration takes place after the recovery). All
other LTGs which are created in the new APS V17/CCNC, but not ACT in the old APS, must be
in status PLA (H'07) and power switched on -for activation- or in status PLA (H'07) and power
switched off –for non-activation-.

Inquiry of the actual LTG status in the CP113D, APS V11:

CP113D

/ <STAT LTG: LTG=X-X;

! States of LTGs:

Original Target
V11 V17/CCNC
all LTGs = ACT PLA = 07
all LTGs < > ACT MBL = 08

4-42 P30305-X1118-G503-01-7618
Inquiry of the actual LTG status in the CP113E, APS V17/CCNC:
In the Installation Recovery mode the status request “STAT LTG: LTG=X-X“ does not
indicate the actual LTG status. For this purpose a display of the semipermanent LTG status
table is required.

CP113E

/ <EXEC CMDFILE: FILE=CF.17.HEXLTGG503;

! OFFSET CONTENT HEX


-----------+---------------------------------------+---
H´00027140 07070707 07070707 07070707 07070707
H´00027150 07070707 07070707 07070707 07070707
H´00027160 07070707 07070707 07070707 07070707
... ... ... ... ...

Note: The second byte represents LTG 0-1.

Table of hex values and the corresponding LTG states:

H'00 = UNA H’01 = CBL H’02 = NAC H’03 = SEZ H'04 = STB
H’05 = ACT H’06 = RES (ACT) H’07 = PLA H’08 = MBL

If necessary, configure LTGs to MBL and then to PLA.

If necessary switch off power from the affected LTG(s)

P30305-X1118-G503-01-7618 4-43
4.32. Checking the SN States / CP113E
In the Installation Recovery mode the status request “STAT MB/SN“ does not indicate the
actual MB/SN status. For this purpose a display of the semipermanent MB/SN status table is
required.

Inquiry of the actual SN status in the CP113E, APS V17/CCNC:

CP113E

/ <EXEC CMDFILE: FILE=CF.17.HEXSNBG503;

! OFFSET CONTENT HEX


----------+---------------------------------------
TSG 0-0 TSG 0-1 TSG 0-2 TSG 0-3
H´00000804 07xx... 07xx... 07xx... 07xx...
TSG 0-4 TSG 0-5 TSG 0-6 TSG 0-7
H´00000814 07xx... 07xx... 07xx... 07xx...
- - - - - - - - - - - - - - - - - - - - - - - - - - - -
H´00000824 07xx... 07xx... 07xx... 07xx...
H´00000834 07xx... 07xx... 07xx... 07xx...
H´00000844 07xx... 07xx... 07xx... 07xx...
H´00000854 07xx... 07xx... 07xx... 07xx...
H´00000864 07xx... 07xx... 07xx... 07xx...
H´00000874 07xx... 07xx... 07xx... 07xx...
- - - - - - - - - - - - - - - - - - - - - - - - - - - -
TSG 1-0 TSG 1-1 TSG 1-2 TSG 1-3
H´00000884 07xx... 07xx... 07xx... 07xx...
TSG 1-4 TSG 1-5 TSG 1-6 TSG 1-7
H´00000894 07xx... 07xx... 07xx... 07xx...
- - - - - - - - - - - - - - - - - - - - - - - - - - - -
H´000008A4 07xx... 07xx... 07xx... 07xx...
H´000008B4 07xx... 07xx... 07xx... 07xx...
H´000008C4 07xx... 07xx... 07xx... 07xx...
H´000008D4 07xx... 07xx... 07xx... 07xx...
H´000008E4 07xx... 07xx... 07xx... 07xx...
H´000008F4 07xx... 07xx... 07xx... 07xx...
- - - - - - - - - - - - - - - - - - - - - - - - - - - -
SSG 0-0 SSG 0-1 SSG 0-2 SSG 0-3
H´00000904 07xx... 07xx... 07xx... 07xx...
- - - - - - - - - - - - - - - - - - - - - - - - - - - -
SSG 1-0 SSG 1-1 SSG 1-2 SSG 1-3
H´00000944 07xx... 07xx... 07xx... 07xx...
- - - - - - - - - - - - - - - - - - - - - - - - - - - -

Table of hex values and the corresponding SN states:

H'00 = UNA H’01 = CBL H’02 = NAC H’03 = SEZ H'04 = STB
H’05 = ACT H’06 = RES (ACT) H’07 = PLA H’08 = MBL

! The status of all SN units TSG and SSG must be PLA = 07.
If the status is MBL = 08 or ACT = 06, the TSG/SSGs must be configured to PLA =
07.

CP113E

/ <CONF TSG: SN=0, TSG=<tsg-no>,OST=PLA;


<CONF SSG: SN=0, SSG=<ssg-no>, OST=PLA;

4-44 P30305-X1118-G503-01-7618
4.33. Checking the MB(B) States / CP113E

Inquiry of the actual MB status in the CP113E, APS V17/CCNC:

CP113E

/ <EXEC CMDFILE: FILE=CF.17.HEXMBBG503;

! OFFSET CONTENT HEX


----------+---------------------------------------
MBUL 0-0 MBUL 0-1 MBUL 0-2 MBUL 0-3
H´00000000 07xx... 07xx... 07xx... 07xx...
MBUL 0-4 MBUL 0-5 MBUL 0-6 MBUL 0-7
H´00000010 07xx... 07xx... 07xx... 07xx...
- - - - - - - - - - - - - - - - - - - - - - - - - - - -
H´00000020 07xx... 07xx... 07xx... 07xx...
H´00000030 07xx... 07xx... 07xx... 07xx...
H´00000040 07xx... 07xx... 07xx... 07xx...
H´00000050 07xx... 07xx... 07xx... 07xx...
H´00000060 07xx... 07xx... 07xx... 07xx...
H´00000070 07xx... 07xx... 07xx... 07xx...
- - - - - - - - - - - - - - - - - - - - - - - - - - - -
MBUL 1-0 MBUL 1-1 MBUL 1-2 MBUL 1-3
H´00000080 07xx... 07xx... 07xx... 07xx...
MBUL 1-4 MBUL 1-5 MBUL 1-6 MBUL 1-7
H´00000090 07xx... 07xx... 07xx... 07xx...
- - - - - - - - - - - - - - - - - - - - - - - - - - - -
H´000000A0 07xx... 07xx... 07xx... 07xx...
H´000000B0 07xx... 07xx... 07xx... 07xx...
H´000000C0 07xx... 07xx... 07xx... 07xx...
H´000000D0 07xx... 07xx... 07xx... 07xx...
H´000000E0 07xx... 07xx... 07xx... 07xx...
H´000000F0 07xx... 07xx... 07xx... 07xx...
- - - - - - - - - - - - - - - - - - - - - - - - - - - -
MBUS 0-0 MBUS 0-1 MBUS 0-2 MBUS 0-3
H´00000100 07xx... 07xx... 07xx... 07xx...
- - - - - - - - - - - - - - - - - - - - - - - - - - - -
H´00000200 07xx... 07xx... 07xx... 07xx...
H´00000300 07xx... 07xx... 07xx... 07xx...
H´00000400 07xx... 07xx... 07xx... 07xx...
- - - - - - - - - - - - - - - - - - - - - - - - - - - -
MBUS 1-0 MBUS 1-1 MBUS 1-2 MBUS 1-3
H´00000500 07xx... 07xx... 07xx... 07xx...

Table of hex values and the corresponding MB states:

H'00 = UNA H’01 = CBL H’02 = NAC H’03 = SEZ H'04 = STB
H’05 = ACT H’06 = RES (ACT) H’07 = PLA H’08 = MBL

! The status of all MB units MBUL and MBUS must be PLA = 07.
If the status is MBL = 08 or ACT = 06, the MBUL/MBUSs must be configured to
PLA = 07.

P30305-X1118-G503-01-7618 4-45
CP113E

/ <CONF MBUL: MB=0, MBUL =<mbul-no>, OST=MBL;


<CONF MBUL: MB=0, MBUL =<mbul-no>, OST=PLA;
<CONF MBUS: MB=0, MBUS=<mbus-no>, OST=MBL;
<CONF MBUS: MB=0, MBUS=<mbus-no>, OST=PLA;

Attention: If LTGs are in MBL, it is not possible to configure the corresponding MBUL/TSG
from MBL to PLA.

4.34. Checking the CCNP States / CP113E


CP113E

/ <STAT CCNC:UNIT=CCNP-X;

! CCNP-0 in STB/NAC
CCNP-1 in ACT/ACT

4.35. CCG Status Request / CP113E


Inquiry of the CCG status in APS V17/CCNC:

CP113E

/ <STAT CCG;

! CCG-0 in UNA, CCG-1 in UNA

4-46 P30305-X1118-G503-01-7618
4.36. SYP Status Request / CP113E
Inquiry of the SYP status in APS V17/CCNC:

CP113E

/ <STAT SYP;

! SYP in UNA

4.37. Interrogation of DIU and CR States


The DIU and CR states have to be identical in both APS versions V11 and V17/CCNC.
For status inquiry, the following two command files are available:

Note:
The comparison of the states may require a long time in big switches without external tool.

Inquiry of the actual DIU status in APS V11:

CP113D

/ <EXEC CMDFILE:FILE=CF.11.DIUSTATG503; DIU and CR inquiry in the SS

Inquiry of the actual DIU status in APS V17/CCNC:

CP113E

/ <EXEC CMDFILE:FILE=CF.17.DIUSTATG503; DIU and CR inquiry in the NSS

Compare and configure to the correct status in V17/CCNC

P30305-X1118-G503-01-7618 4-47
4.38. Deactivation of CSC- and X25-Links / CP113D
Check if existing links are in use, if not deactivate links.

CP113D

/ <DISP JOB;

<DISP SESSION:USERID=X;

4.38.1. Deactivating CSC-Links


CSC-links CSC-0 up to 3 can be deactivated using command file “CF.11.PLACSCG503“.

CP113D

/ <EXEC CMDFILE:FILE=CF.11.PLACSCG503;

! All CSC-links in PLA

4.38.2. Deactivating X25-Links


X25-links X25LINK-0 up to 7 can be deactivated using command file “CF.11.PLAX25G503“.

CP113D

/ <EXEC CMDFILE:FILE=CF.11.PLAX25G503;

! All X25-links in PLA

4.39. Blocking Subscriber Entries / CP113D


Subscriber controlled inputs SCI have to be blocked before the current logfile is closed.

CP113D

<EXEC CMDFILE: FILE=PA.11.B2925L2Z;

4-48 P30305-X1118-G503-01-7618
4.40. Processing Logfile (2) / CP113D

4.40.1. Checking for Security Keywords


Executing REGEN run on subsystem FA:

CP113D

/ <DACT FNS: FNS=RG;


<EXEC REGEN: FUNC=FA, VSN=SYSVSN, LANG=<lang>, SIZE=24;

Attention: If the APS syntax is in English, the parameter “LANG“ must be NAT.
For all other syntaxes, the parameter “LANG“ must be ENG.

<ACT FNS: FNS=RG;

Check if the file RG.FA.<exchid> contains Security Keywords:

CP113D

/ <DISP FILE:FILE=RG.;

<EXEC EDTS8;

*R RG.FA.<exchid>
*P& “SECURE=Y“
*D&
*END

Attention: If Security Keywords have been found in the APS, the file
RG.FA.<exchid> has to be saved to tape.

Saving the regenerated RG.FA.<exchid> to tape for reformation on PC:

Mount MO in MOD-0

CP113D

/ <INIT MO: VSN=<mo-no>, CD=EBC, MOD=0;


<TRANS FILE: FILE=RG.FA.<exchid>, VSNR==<vsn>,COPMOD=SSWF;
<DISP FILE: VSN=<mo-no>;
<RSET MO:MOD=0;

Remove MO from MOD-0

Continue with checking the logfile. For further processing of the file
RG.FA.<exchid>, see procedure "Database Handling V9....V17 to V17" /2/.

P30305-X1118-G503-01-7618 4-49
4.40.2. Checking the Logfile
Switching the LOG function:

CP113D

/ <DISP FILE: FILE=LG.; Interrogation of logfiles


<STAT LOG; LOG state is on
<MOD LOGFILE: FILE=<file-name>; Close current logfile and open new logfile
<DISP FILE: FILE=LG.; Interrogation of logfiles

Copying the terminated original logfile:

CP113D

/ <EXEC EDTS8; For reasons of safety, the logfile


*R LG.<name>.A1 should be stored under another name
*W LOG1 before reformatting, e.g. LOG1

Check logfile for syntax conversion:

Check logfile if conversion on OMT in EDTS8 is possible or conversion on


PC is necessary

CP113D

/ *W LG.<name>.A1
*Y
*D&
*END

4-50 P30305-X1118-G503-01-7618
4.40.3. Saving and Converting Logfile (2) / Dest. APS V17/CCNC
The LG-logfile (2) is saved on MO and converted on PC/Laptop, the LQ-logfile (2) is saved on
MO for incorporation in APS V17/CCNC:

Save the LQ-logfile (2), if Q3 is active:

Mount MO in MOD-0

CP113D

/ <INIT MO: VSN=<mo-no>,MOD=0,CD=EBC;

<DACT FNS: FNS=LQ;


<TRANS FILE: FILE=LQ.<logfile-name>.A1,VSNR=<mo-no>, COPMOD=SSWF;

<DISP FILE: VSN=<mo-no>;

<RSET MO:MOD=0;

Remove MO from MOD-0 and hold it ready for incorporation of the LQ-logfile
in APS V17/CCNC

Save the LG-logfile (2):

Mount MO in MOD-0

CP113D

/ <INIT MO: VSN=<mo-no>,MOD=0,CD=EBC;


<DACT FNS: FNS=LG;

CP113D

/ <TRANS FILE: FILE=LG.<logfile-name>.A1,VSNR=<mo-no>, COPMOD=SSWF;

<DISP FILE: VSN=<mo-no>;


<ACT FNS: FNS=X;

<RSET MO:MOD=0;

Remove MO from MOD-0

Convert the LG-logfile (2) from V11 to V17/CCNC syntax, corresponding to


procedure ”Database Handling V9….V17 to V17” /2/

P30305-X1118-G503-01-7618 4-51
4.41. Incorporating the Logfile (2) / CP113E
The logfiles available since the processing of logfile (2) must be incorporated.

CP113E

/ <DACT FNS: FNS=LG;

<DISP FILE:FILE=LG.;

<DEL FILE:FILE=LG.; If old log files are available

Load LG-logfile (2):

Mount MO containing the converted LG-logfile in MOD-0

CP113E

/ <TRANS FILE: FILE= LG., VSNS=LOGTAP, MODE=CRD;

<DISP FILE: FILE=LG.;

<RSET MO:MOD=0;

Remove MO from MOD-0

Incorporate LG-logfile (2):

CP113E

/ <EXEC CMDFILE: FILE=LG.<file-name>.A1, CHOL=Y; Syntax check for each LG-logfile

<ACT IAOPT: BLBUFR=ADMREC; Suppression of AMA-Tickets

<DISP FILE:FILE=CA.; No CA files with extension .REL or .NEW


available, if not, wait until these files are
deleted autom. ”Metering critical commands
are allowed again”

<EXEC CMDFILE: FILE=LG.<file-name>.A1; For each LG-logfile. If available the corresponding


LQ-logfile is started autom. from the LG-logfile

<EXEC CMDFILE: FILE=LG. KEYWD; Incorporation of KEYWD.LG ( if existing)


The file contains the delta of the ENTRKEYWORD
commands with SECURE=Y(ES)

<CAN IAOPT: BLBUFR=ADMREC;

<ACT FNS: FNS=LG;

4-52 P30305-X1118-G503-01-7618
5. PHASE 2: CP CHANGE

To be started on upgrade day during low traffic hours

5.1. Switch over MB/CCG/SN-1, SYPC from CP113D to CP113E


Sequence of operations:

- Deactivating SN/MB/CCG-1 and SYPC in the CP113D system


- Disconnecting MB/CCG-1 and SYPC from CP113D
- Connecting MB/CCG-1 and SYPC to the CP113E

5.1.1. Deactivation of SN/MB/CCG-1, SYPC / CP113D


CP113D

/ <STAT MB;

<STAT CCG;

<STAT SN;

<STAT SYP;

! MB-0 in ACT, MB-1 in ACT


CCG-0 in ACT, CCG-1 in STB
SN-0 in ACT, SN-1 in STB
SYP in ACT

If necessary, configure required states.

CP113D

/ <CONF SN:SN=1,OST=MBL;

<CONF MB:MB=1,OST=MBL;

<CONF CCG:CCG=1,OST=MBL;

<CONF SYP:OST=MBL;

P30305-X1118-G503-01-7618 5-1
5.1.2. Disconnecting MB/CCG-1 and SYPC from CP113D
- Connecting cables CP113D, R:DEV D0,IOP-0,1,2,3 to R:MB/CCG(B)/R:MB(B), MB-1,3,5,7,
and CCG-1, see Chapter 12.4.1.1

Unplug the cables on the side MB-1,3,5,7 and CCG-1 only:

- VAR 064 to 067: IOP-0,1 - MB-1 (4 cables) Stage up to DE54

- VAR 064 to 067: IOP-0,1 - CCG-1 (4 cables)

- VAR 064 to 067: IOP-0,1 - MB-3 (4 cables) Stage DE52,54

- VAR 066 to 067: IOP-2,3 - MB-5 (4 cables) Stage DE54

- VAR 066 to 067: IOP-2,3 - MB-7 (4 cables) Stage DE54

- Connecting cables CP113D, R:DEV D0, IOP-0,1 to R:MB/CCG(B), F:SYPC, see


Chapter 12.4.2

Unplug the cables on the side SYPC only:

- VAR 044: IOP-0,1 - SYPC (4 cables)

5-2 P30305-X1118-G503-01-7618
5.1.3. Connecting MB/CCG-1 and SYPC to CP113E
- Connecting cables CP113E, R:CP113E, IOP-0,1,2,3 - R:MB/CCG(B)/R:MB(B), MB-1,3,5,7
and CCG-1, see Chapter 12.4.1.1

Plug in the cables on the side MB-1,3,5,7 and CCG-1 only:

- VAR 3012: IOP-0,1 - MB-1 (4 cables) Stage up to DE54

- VAR 3011: IOP-0,1 - CCG-1 (4 cables)

- VAR 3013: IOP-0,1 - MB-3 (4 cables) Stage DE52,54

- VAR 3014: IOP-2,3 - MB-5 (4 cables) Stage DE54

- VAR 3014: IOP-2,3 - MB-7 (4 cables) Stage DE54

- VAR3011: IOP-0,1 - CCG-1 (2 cables) New connection with


CP113E only

- Connecting cables CP113E, R:CP113E, F:EIOP-0,1 - R:MB(B)/CCG(B), SYPC, see


Chapter 12.4.2

Plug in the cables on the side SYPC only:

- VAR 3100: IOP-0,1 - SYPC (4 cables)

5.1.4. Check of MB(B) – IOPMB connection / CP113E

CP113E

/ <CONF MB:MB=1,OST=MBL;

<CONF MB:MB=1,OST=ACT;

<CONF MB:MB=1,OST=MBL;

CP113E

/ <EXEC CMDFILE: FILE=CF.17.PLAMBBG503;

P30305-X1118-G503-01-7618 5-3
In the Installation Recovery mode the status request “STAT MB/SN“ does not indicate the
actual MB/SN status. For this purpose a display of the semipermanent MB/SN status table is
required.

Inquiry of the actual MB status in the CP113E, APS V17/CCNC:

CP113E

/ <EXEC CMDFILE: FILE=CF.17.HEXMBBG503;

! OFFSET CONTENT HEX


----------+---------------------------------------
MBUL 0-0 MBUL 0-1 MBUL 0-2 MBUL 0-3
H´00000000 07xx... 07xx... 07xx... 07xx...
MBUL 0-4 MBUL 0-5 MBUL 0-6 MBUL 0-7
H´00000010 07xx... 07xx... 07xx... 07xx...
- - - - - - - - - - - - - - - - - - - - - - - - - - - -
H´00000020 07xx... 07xx... 07xx... 07xx...
H´00000030 07xx... 07xx... 07xx... 07xx...
H´00000040 07xx... 07xx... 07xx... 07xx...
H´00000050 07xx... 07xx... 07xx... 07xx...
H´00000060 07xx... 07xx... 07xx... 07xx...
H´00000070 07xx... 07xx... 07xx... 07xx...
- - - - - - - - - - - - - - - - - - - - - - - - - - - -
MBUL 1-0 MBUL 1-1 MBUL 1-2 MBUL 1-3
H´00000080 07xx... 07xx... 07xx... 07xx...
MBUL 1-4 MBUL 1-5 MBUL 1-6 MBUL 1-7
H´00000090 07xx... 07xx... 07xx... 07xx...
- - - - - - - - - - - - - - - - - - - - - - - - - - - -
H´000000A0 07xx... 07xx... 07xx... 07xx...
H´000000B0 07xx... 07xx... 07xx... 07xx...
H´000000C0 07xx... 07xx... 07xx... 07xx...
H´000000D0 07xx... 07xx... 07xx... 07xx...
H´000000E0 07xx... 07xx... 07xx... 07xx...
H´000000F0 07xx... 07xx... 07xx... 07xx...
- - - - - - - - - - - - - - - - - - - - - - - - - - - -
MBUS 0-0 MBUS 0-1 MBUS 0-2 MBUS 0-3
H´00000100 07xx... 07xx... 07xx... 07xx...
- - - - - - - - - - - - - - - - - - - - - - - - - - - -
H´00000200 07xx... 07xx... 07xx... 07xx...
H´00000300 07xx... 07xx... 07xx... 07xx...
H´00000400 07xx... 07xx... 07xx... 07xx...
- - - - - - - - - - - - - - - - - - - - - - - - - - - -
MBUS 1-0 MBUS 1-1 MBUS 1-2 MBUS 1-3
H´00000500 07xx... 07xx... 07xx... 07xx...

Table of hex values and the corresponding MB states:

H'00 = UNA H’01 = CBL H’02 = NAC H’03 = SEZ H'04 = STB
H’05 = ACT H’06 = RES (ACT) H’07 = PLA H’08 = MBL

! The status of all MB units MBUL and MBUS must be PLA = 07.
Units in MBL = 08 or ACT = 06 must be configured to PLA = 07.

5-4 P30305-X1118-G503-01-7618
CP113E

/ <CONF MBUL: MB=0, MBUL =<mbul-no>, OST=MBL;


<CONF MBUL: MB=0, MBUL =<mbul-no>, OST=PLA;
<CONF MBUS: MB=0, MBUS=<mbus-no>, OST=MBL;
<CONF MBUS: MB=0, MBUS=<mbus-no>, OST=PLA;

Attention: If LTGs are in MBL, it is not possible to configure the corresponding MBUL/TSG
from MBL to PLA.

5.2. Blocking Subscriber Controlled Inputs/CP113E

SCI’s have to be blocked before and released after the startup and test of the APS V17.
Additionally the upgrade option “OPSTAT” is set to “SPECIAL2”, so the SCI’s are written into
the logfile, not only into file SY.VSD.BACKUP (for ev.Fallback).

CP113E

/ <DISP UPGRDOPT;

! UPGRADE OPTIONS DATA

FSU BLKSCI OPSTAT


-----------------------------
NO NO NORMAL

CP113E

/ <SET UPGRDOPT: BLKSCI=YES, OPSTAT=SPECIAL2;

5.3. Updating the Charge Files / CP113D


Command file ”CF.11.UPDFILEG503” is used for the last update of the CA-, IA- and
IACHASTA- files on disk. The saving of these files, regeneration of meters etc. is done later
after the CP- change.

CP113D

/ <EXEC CMDFILE:FILE=CF.11.UPDFILEG503;

5.4. Deactivation of MDD-1 / CP113D


The MDD-1 is switched off for safety reasons.

CP113D

/ <CONF MDD:MDD=1,OST=MBL;

Switch off power from MDD-1

P30305-X1118-G503-01-7618 5-5
This page was left intentionally blank!

5-6 P30305-X1118-G503-01-7618
6. PHASE 3: CUT OVER
The following procedure steps are executed:

- Stopping the CP113D system


- Disconnection of SN/MB/CCG/CCNP-0 from the CP113D system
- Connection of SN/MB/CCG/CCNP-0 to the CP113E system
- Startup of the CP113E with recovery level ISTART2F

6.1. Stopping System CP113D APS V11

!! SYSTEM INTERRUPTION !!

To be started in low traffic period

CP113D

/ <STAT SSP;

! BAP-0 is MAS, BAP-1 is SPR

CP113D

/ <COM BAP; If status is different

<CONF BAP:BAP=1,OST=MBL;

Switch off power from BAP-1

Press BOOT key on BAP-0

! System messages:

IPL113: MANUAL START - CURRENT CONFIGURATION


UNIT STATUS TEST
********************************************
BAP-0 MASTER NO TEST RUN
BAP-1 UNA BAP-SPARE
etc.

IPL113: ENTER PARAMS


TO DIAGNOSE MEMORY : "DIAG;"
TO FORMAT MEMORY : "FORMAT;"
TO CONTINUE : ";<ENTER>"
CP113D

/ ;

P30305-X1118-G503-01-7618 6-1
IPL113: MANUAL START ENTER PARAMS
TO START APS MANUALLY :"MANUALLY;"
TO START INSTALLAT.RECOV.:"INSTALLATION;"
TO START UTILITY(MONITOR):"UTILITY;"
TO STOP INITIAL START :"STOP;"
TO START APS AUTOMATICALLY:";ETX"

CP113D

/ STOP;

! I N I T I A L S T A R T S T O P P E D

Switch off power from BAP-0

6.2. Switch over MB/CCG/SN/CCNP-0 from CP113D to CP113E

6.2.1. Disconnecting MB/CCG/CCNP-0 from CP113D


- Connecting cables CP113D, R:DEV D0,IOP-0,1,2,3 to R:MB/CCG(B)/R:MB(B), MB-0,2,4,6,
and CCG-0, see Chapter 12.4.1.2

Unplug the cables on the side MB-0,2,4,6 and CCG-0 only:

- VAR 064 to 067: IOP-0,1 - MB-0 (4 cables) Stage up to DE54

- VAR 064 to 067: IOP-0,1 - CCG-0 (4 cables)

- VAR 064 to 067: IOP-0,1 - MB-2 (4 cables) Stage DE52,54

- VAR 066 to 067: IOP-2,3 - MB-4 (4 cables) Stage DE54

- VAR 066 to 067: IOP-2,3 - MB-6 (4 cables) Stage DE54

- Connecting cables CP113D, R:DEV D0, IOP-0,1/IOP-2,3 to R:CCNP, F:CCNP-0, see


Chapter 12.4.2

Unplug the cables on the side CCNP-0 only:

- VAR 048: IOP-0,1 - CCNP-0 (4 cables) Stage up to DE52

- VAR 049: IOP-2,3 - CCNP-0 (4 cables) Stage DE54

6-2 P30305-X1118-G503-01-7618
6.2.2. Connecting MB/CCG/CCNP-0 and SYPC to CP113E
- Connecting cables CP113E, R:CP113E, F:PIOP-0,1,2,3 - R:MB/CCG(B)/R:MB(B),
MB-0,2,4,6 and CCG-0, see Chapter 12.4.1.2

Plug in cables on the side MB-0,2,4,6 and CCG-0 only:

- VAR 3012: IOP-0,1 - MB-0 (4 cables) Stage up to DE54

- VAR 3011: IOP-0,1 - CCG-0 (4 cables)

- VAR 3013: IOP-0,1 - MB-2 (4 cables) Stage DE52,54

- VAR 3014: IOP-2,3 - MB-4 (4 cables) Stage DE54

- VAR 3014: IOP-2,3 - MB-6 (4 cables) Stage DE54

- VAR 30311: IOP-0,1 - CCG-0 (2 cables) New connection with


CP113E only

- Connecting cables CP113E, R:CP113E, F:EIOP-0,1 - R:MB(B)/CCG(B), SYPC, see


Chapter 12.4.2

Plug in the cables on the side SYPC only:

- VAR 3100: IOP-0,1 - SYPC (4 cables)

- Connecting cables CP113E, R:CP113E, F:EIOP-0,1 and F:BIOP-2,3 - R:CCNP, CCNP-0,


see Chapter 12.4.3.2

Plug in cables on the side CCNP-0 only:

- VAR 3101: IOP-0,1 - CCNP-0 (4 cables) Stage up to DE52

- VAR 3102: IOP-2,3 - CCNP-0 (4 cables) Stage DE54

P30305-X1118-G503-01-7618 6-3
6.3. Ending Installation Recovery / CP113E
Note:
If the CP113E is out of Installation Recovery a Manual Recovery is to be executed.
In this case continue with Chapter 6.5

CP113E

/ <END INSTALL;

6.4. Startup of the CP113E System with ISTART2F, APS V17/CCNC

CP113E

/ <RECOV SYSTEM: LEVEL=ISTART2F;

! The startup with APS V17/CCNC is now started

Observe the trackpoints on the MP / BAP-0 and BAP-1 for the startup

! BAP-0 trackpoints Axxx, B254 etc

! System messages:

Initialization of memory

##### BAP-0 IS LOADING APS - DISPLAY : xxxx #####

** SYSTEM - RECOVERY ALARM MMN:SW330-0001

DATE : xx-xx-xx
TIME : xx:xx:xx
PERFORMED LEVEL : ISTART2F
ADDITIONAL INFO : MEMORY INITIALIZED

APS GENERATION : 17xxxxx

6-4 P30305-X1118-G503-01-7618
! System messages:

FCP RECOVERY REPORT

ACTUAL CONFIGURATION: UNIT OST LOAD DEVICE


-------+----+-----------
MDD-00 ACT YES
MDD-01 ACT NO

ACTUAL GENERATION : NAME CREATION DATE LAST CREATED


---------+------------------+------------
17xxxxxx xx-xx-xx xx:xx:xx YES

FCP UPDATE REPORT

LAST EXECUTED TRANSACTION : DATE = xx-xx-xx xx:xx:xx


JOBNO= xxxx

FILES UPDATED BY LAST TRANSACTION :


FILENAME: GENERATION:
-----------------------------------
SY.SEMILIB 17xxxxxx

##### INITIALSTART PROGRESS MESSAGE #####


LTG-CODE DOWNLOADING LOADTYPE xx
START 1. OF xx CODE SEGMENTS xx:xx:xx

##### INITIALSTART PROGRESS MESSAGE #####


LTG-CODE DOWNLOADING LOADTYPE xx
START x. OF xx CODE SEGMENTS xx:xx:xx

##### INITIALSTART PROGRESS MESSAGE #####


LTG-CODE DOWNLOADING LOADTYPE xx
START 1. OF xx CODE SEGMENTS xx:xx:xx

##### INITIALSTART PROGRESS MESSAGE #####


LTG-CODE DOWNLOADING LOADTYPE xx
START x. OF xx CODE SEGMENTS xx:xx:xx

##### INITIALSTART PROGRESS MESSAGE #####


START OF DIGIT TABLE DOWNLOADING xx:xx:xx

##### INITIALSTART PROGRESS MESSAGE #####


START OF LTU DATA DOWNLOADING xx:xx:xx

##### INITIALSTART PROGRESS MESSAGE #####


START OF LTG PORTDATA DOWNLOADING xx:xx:xx

##### INITIALSTART PROGRESS MESSAGE #####


START OF LTG ACTIVATION xx:xx:xx

##### INITIALSTART PROGRESS MESSAGE #####


DLU/V5IF PORT DATA DOWNLOADING
START 1. DLU / V5IF xx:xx:xx

P30305-X1118-G503-01-7618 6-5
! System messages:

##### INITIALSTART PROGRESS MESSAGE #####


END OF LTG LOADING xx:xx:xx

SYSTEM - RECOVERY INFORMATION

REASON : SYSTEM UPGRADE

DATE : xx-xx-xx
TIME : xx:xx:xx
UNIT : BAPM

REQUESTED RECOVERY LEVEL : ISTART2F


PERFORMED RECOVERY LEVEL : ISTART2F

CALL PROCESSING STARTED : xx:xx:xx

DURATION OF SERVICE INTERRUPTION: xxx SECONDS


RECOVERY DURATION : xxx SECONDS

RESULT : RECOVERY TERMINATED WITHOUT FAILURE

SUPPLEMENTARY INFORMATION:

MEMORY INITIALIZED
PERIPHERY RELOADED WITH CODE AND DATA

APS GENERATION : 17xxxxxx

CRITICAL STATES
---------------
NO (MORE) DATA FOR DISPLAY AVAILABLE

! See system message for the system outage time during change over:

SYSTEM UPGRADE INFORMATION:


SYSTEM OUTAGE TIME: xxx SEC

6-6 P30305-X1118-G503-01-7618
Recovery successful?

NO: Manual Startup, see Chapter 6.5

YES:

continue with Chapter 6.6

6.5. Manual Startup of the CP113E System APS V17/CCNC


Attention:
To be executed only, if the ISTART2F started from the Installation Recovery has failed !

Press BOOT key on CMYE-1 at CP113E

CP113E

FORMAT;

MAN;

IOC-0;

17xxxxxx;

FORCED;

! A Manual Startup ISTART2F with LTG loading is carried out

P30305-X1118-G503-01-7618 6-7
Manual Recovery successful?

YES: continue with Chapter 6.6

NO:

don’t panic and continue with Chapter 8 (Fallback)

6.6. System Status Inquiry / CP113E

OMT-SW: XENIX OMT-SW: UNIX

CP113E CP113E

/ Press the request key F1 / <STAT SSP;

PLEASE ENTER USERID PLEASE ENTER USERID


<userid> <userid>

PLEASE ENTER CURRENT PLEASE ENTER CURRENT


PASSWORD PASSWORD
<password> <password>

<STAT SSP;

Message: STATSSP EXEC´D

CP113E

/ <STAT SSP; Full redundancy or status SEZ except CSC/X25-links


<STAT LTG: LTG=X-X; All LTGs in ACT, corresponding to old APS
<STAT DLU: DLU=X; No degradation
<STAT MB; MB-0 in ACT, MB-1 in ACT
<STAT SN; SN-0 in ACT/STB, SN-1 in STB/ACT
<STAT CCG; CCG-0 in ACT/STB, CCG-1 in STB/ACT
<STAT SYP; SYP in ACT
<STAT CCNC: UNIT=CCNP-X; CCNP-0 in ACT/STB, CCNP-1 in STB/ACT

<DISP TIME; Secure

Check the above system states and configure to normal states if necessary
(except CSC/X25-links)

6-8 P30305-X1118-G503-01-7618
CP113E

/ <START AUDIT:NAME=NUCAUDIT;
<DISP C7LINK:LSNAM=X; Corresponding to APS V11
<DISP NUC; ”
<DISP IPNUC; ”

Note:
It is possible that some IPNUC are in status UNA. These IPNUC have to be deactivated and
activated.

CP113E

/ <DACT IPNUC:NUC=<name>;
<ACT IPNUC:NUC=<name>;

! If command ”DACT IPNUC” is rejected, configure the corresponding port:

CP113E

/ <CONF PORT:LTG=<ltg-no>,CHPOS=<ch-pos>,OST=MBL/PLA/MBL/ACT;

! If this sequence of commands is also not successful configure the corresponding


frame handler:

CP113E

/ <CONF FHM:LTG=<ltg-no>, FHM=<no>,OST=MBL/PLA/MBL/ACT;

6.7. Activating CAPs / CP113E


CP113E

/ <STAT SSP:UNITS=CU; Interrogation of CAP states

<EXEC CMDFILE:FILE=CF.17.ACTCAPG503; Activation of CAP-0 - CAP5, if necessary

! Ignore error message for CAPs not available


All available CAPs in ACT

P30305-X1118-G503-01-7618 6-9
6.8. System Test APS V17/CCNC / CP113E
Deleting alarms:

CP113E

/ <DISP ALARM;
<SET ALSTAT:ALSTAT=C,MSGNO=<x>; x = see ”DISP ALARM”, object RECOV

Inquiry of system status APS V17/CCNC with the command file ”CF.17.SYSTATG503”:

CP113E

/ <STAT LOG; LOG function must be activated


<SET LOG:FILE=<logfile-name>,SIZE=24; If LOG function is deactivated

<EXEC CMDFILE: FILE=CF.17.SYSTATG503;

! Full redundancy, except MDD-1 and CSC/X25-links

The switching equipment must be checked in accordance with the prepared concept.
In case of faults, a decision must be made whether a fallback to the APS V11 is to be
initiated.

System check according to test concept, see Chapter 4.2

Is the System Check ok?

NO: continue with Chapter 8 (Fallback to V11)

YES:

continue with Chapter 7

6-10 P30305-X1118-G503-01-7618
7. PHASE 4: POST - PROCESSING

7.1. Checking Charge Files / CP113E


Check IA files:

CP113E

/ <DISP IAFEAT;
<DISP FILE:FILE=IA.;

! IA features activated, all IA files available

Check IACHASTA files:

CP113E

/ <DISP IAFEAT;
<DISP IACRG;
<DISP FILE:FILE=IA.;
<DISP FILE:FILE=CA.;

! IACHASTA registration activated, all IACHASTA files available

Check CA files:

CP113E

/ <DISP EXDDAT;
<DISP FILE:FILE=CA.;

! Meter types activated, corresponding CA files available

7.2. Restoring original Charge Meter Saving / CP113E


If meter saving has been shifted to a time-uncritical point, the original value has to be restored.

CP113E

/ <DISP METSAV;
<ENTR METSAV:TIME=<hh-mm>,CHEKNO=<no>; See original value

P30305-X1118-G503-01-7618 7-1
7.3. Unblocking Subscriber Controlled Inputs / CP113E

CP113E

/ <SET UPGRDOPT: BLKSCI=NO;

7.4. Updating the Database / CP113E

Note:
To be executed only if command file “CF.17.UPDATDB“ exists from APS database installation.

CP113E

/ <DISP FILE: FILE=CF.;


<EXEC CMDFILE: FILE=CF.17.UPDATDB, CHOL=Y; If command file is on disk

<EXEC CMDFILE: FILE=CF.17.UPDATDB; If command file is on disk

7.5. Switch over CSC-Links from CP113D to CP113E

7.5.1. Disconnecting CSC-Links from CP113D


Connecting cables R:DEV D0, IOPSCDV-x - CSC-link / Transmission equipment

Unplug cable on side of the MODEM only

7.5.2. Connecting CSC-Links to the CP113E


Connecting cables R:CP113E, IOPUNI-x - CSC-link / Transmission equipment

Plug in cable on side of the MODEM only

Activate CSC-link CSC-0 up to 3 with command file CF.17.ACTCSCG503.

CP113E

/ <EXEC CMDFILE:FILE=CF.17.ACTCSCG503;

! All available CSC-links activated

Test the CSC-links

7-2 P30305-X1118-G503-01-7618
7.5.3. Disconnecting X25-Links from CP113D
Connecting cables R:DEV D0, IOPLAU-x - X25-link / Transmission equipment

Unplug cable on side of MODEM only

7.5.4. Connecting X25-Links to the CP113E


Connecting cable R:CP113E, IOPLAU-x - X25-link / Transmission equipment

Plug in cable on side of MODEM

Activate X25-link X25LINK-0 up to 7 with command file CF.17.ACTX25G503:

CP113E

/ <STAT SSP; IOPLAU-x and LAU-x in ACT

<EXEC CMDFILE:FILE=CF.17.ACTX25G503; Only if no X25-link is activated,


otherwise configure missing links
manually

! All available X25-links activated

Test the X25-links

7.6. Activating Routine Tests

CP113E

/ <ALLOW SSPRT;
<INHIB SSPRT: TESTID=<test-id>; Not available CP units

P30305-X1118-G503-01-7618 7-3
7.7. Starting Installation Recovery APS V11 / CP113D

The Installation Recovery is started for charge file handling.

• The files CA.SU.UCHA, CA.TF.UCHA, CA.TR.UCHA and CA.ST.UCHA, if available, are


saved as account files, the files CA.SU.UCHA and CA.TF.UCHA can also be saved as
regeneration files for meter regeneration in V17/CCNC/CP113E
• The IA- and IACHASTA files are saved for postprocessing
• Project-specific files are saved for the transfer to V17/CCNC/CP113E

CP113D

Switch on power to BAP-0

! As soon as the trackpoint A885 on the MP display disappears, the BOOT key
on BAP-0 must be pressed.

Press BOOT key on BAP-0

CP113D

FORMAT;

INS;

IOC-0;

11xxxxxx;

! After the system message “INSTALL RECOVERY INFORMATION....“


the APS can be started as follows:

OMT-SW: XENIX OMT-SW: UNIX

CP113D CP113D

/ Press the request key F1 / <START FCP;

PLEASE ENTER USERID PLEASE ENTER USERID


<userid> <user id>

PLEASE ENTER CURRENT PASSWORD PLEASE ENTER CURRENT PASSWORD


<password> <password>

CP113D

/ <START FCP;

Message: STARTFCP EXEC´D

7-4 P30305-X1118-G503-01-7618
CP113D

/ <START OM;

<START SFGSW;

<START CSWD;
<DISP TIME;

<ENTR TIME:DATE=<date>,TIME=<time>,WD=<wd>; If time is insecure


<CORR TIME:MODE=SECURE;

Attention:
If the Installation Recovery is exited and the processor changes to STOP, a message is output
indicating that the Installation Recovery must be restarted using the commands above:

*** ERRORS (SWSG, ALARM) DURING INSTALLATION RECOVERY ***


*** NEW INSTALLATION RECOVERY NECESSARY ***

7.8. Starting Processes / CP113D


CP113D
/ <EXEC CMDFILE: FILE=CF.11.PROG503;
<DISP METSAV;

! Wait for command execution before continuing. If command is executed all


processes are started.

7.9. Unblocking Subscriber Controlled Imputs

CP113D

/ <EXEC CMDFILE: FILE=PA.11.B2925L2J;

P30305-X1118-G503-01-7618 7-5
7.10. File handling CP113D

7.10.1. Saving IA Files / CP113D


All available IA charge files IA.ICAMA, IA.ICMAL, IA.ICMOB etc., IACHASTA files and other
existing IA files are to be saved for postprocessing.
File saving via X25-link is not possible in Split Mode and Installation Recovery.

CP113D
/ <DISP IAFEAT; Interrogation of existing features
<DISP FILE:FILE=IA. and files

Note:
If files are empty, the message ERROR: FILE L FC 33 is output.

The command files should not release the IA files after the saving process (no REL CYCFILE),
so that the files can be continued in case of a fallback from MDD-0.

7.10.1.1. Saving File IA.ICAMA / CP113D


Save file IA.ICAMA, using the following procedure, see also OMN:EXCH TA-120, or project-
specific command file.

Mount MO in MOD-0

CP113D
/ <INIT MT: VSN=<mo-no>, MTD=0, CD=ISO;

<ENTR FILEPSW; Input read password if necessary

<TRANS FILE: FILE=IA.ICAMA, VSNR=<mo-no>,COPMOD=POST;

<DISP FILE: VSN=<mo-no>;

<REL CYCFILE: FILE=IA.ICAMA;

<RSET MO:MOD=0;

Remove MO from MOD-0 and label it

7-6 P30305-X1118-G503-01-7618
7.10.1.2. Saving File IA.ICMAL / CP113D
Save file IA.ICMAL, using the following procedure or project-specific command file.

Mount MO in MOD-0

CP113D
/ <INIT MO:VSN=<mo-no>,MOD=0, CD=ISO;

<TRANS FILE: FILE=IA.ICMAL, VSNR=<mo-no>,COPMOD=POST;

<DISP FILE: VSN=<mo-no>;


<REL CYCFILE: FILE=IA.ICMAL;

<RSET MO:MOD=0;

Remove MO from MOD-0 and label it

7.10.1.3. Saving File IA.ICMOB and IA.ICFIR / CP113D


Save files IA.ICMOB and IA.ICFIR, using the following procedure or project-specific command
file.

Mount MO in MOD-0

CP113D
/ <INIT MO: VSN=<mo-no>, MOD=0, CD=ISO;
<TRANS FILE: FILE=IA.ICMOB, VSNR=<mo-no>,COPMOD=POST;
<TRANS FILE: FILE=IA.ICFIR, VSNR=<mo-no>,COPMOD=POST;

<DISP FILE: VSN=<mo-no>;


<REL CYCFILE: FILE=IA.ICMOB;
<REL CYCFILE: FILE=IA.ICFIR;

<RSET MO:MOD=0;

Remove MO from MOD-0 and label it

P30305-X1118-G503-01-7618 7-7
7.10.1.4. Saving File IA.ICIAR / CP113D
Save file IA.ICIAR (IACHASTA-AMA registration) using the following procedure, see also
OMN:EXCH TA-233, or project-specific command file.

CP113D
/ <DISP IACRG; Interrogation of IACHASTA-AMA registration

Mount MO in MOD-0

CP113D
/ <INIT MO: VSN=<mo-no>, MOD=0, CD=ISO; if MOD is used

<ENTR FILEPSW; Input read password

<TRANS FILE: FILE=IA.ICIAR, VSNR=<vsn>, COPMOD=POST;


<DISP FILE: VSN=<mo-no>;

<REL CYCFILE: FILE=IA.ICIAR;

<RSET MO:MOD=0;

Remove MO from MOD-0 and label it

7-8 P30305-X1118-G503-01-7618
7.10.1.5. Saving Files IA.ICIAR1 and IA.ICIAR2 / CP113D
Save files IA.ICIAR1 and IA.ICIAR2 using the following procedure, see also
OMN:EXCH TA-233, or project-specific command file.

Mount MO in MOD-0

CP113D
/ <INIT MO: VSN=<mo-no>, MOD=0, CD=ISO;

<ENTR FILEPSW; Input read password

<TRANS FILE: FILE=IA.ICIAR1, VSNR=<mo-no>, COPMOD=POST;


<TRANS FILE: FILE=IA.ICIAR2, VSNR=<mo-no>, COPMOD=POST;
<DISP FILE: VSN=<mo-no>;

<REL CYCFILE: FILE=IA.ICIAR1;


<REL CYCFILE: FILE=IA.ICIAR2;

<RSET MO:MOD=0;

Remove MO from MOD-0 and label it

7.10.1.6. Saving File IA.ICINA / CP113D


Save file IA.ICINA using the following procedure, see also OMN:EXCH TA-233, or project-
specific command file.

Mount MO in MOD-0

CP113D
/ <INIT MO: VSN=<mo-no>, MOD=0, CD=ISO;

<ENTR FILEPSW; Input read password

<TRANS FILE: FILE=IA.ICINA, VSNR=<mo-no>,COPMOD=POST;

<DISP FILE: VSN=<mo-no>;

<REL CYCFILE: FILE=IA.ICINA;

<RSET MO:MOD=0;

Remove MO from MOD-0 and label it

P30305-X1118-G503-01-7618 7-9
7.10.2. Saving File IA.IC<type> / CP113D
Save any other file IA.IC<type>, using the following procedure or project-specific command file.

Mount MO in MOD-0

CP113D
/ <INIT MO: VSN=<mo-no>, MOD=0, CD=ISO;

<TRANS FILE: FILE=IA.IC<type>, VSNR=<mo-no>,COPMOD=POST;

<DISP FILE: VSN=<mo-no>;

<REL CYCFILE: FILE=IA.IC<type>;

<RSET MO:MOD=0;

Remove MO from MOD-0 and label it

7.10.3. Saving IACHASTA Files / CP113D


All available IACHASTA files CA.IR. must be saved for postprocessing.

CP113D
/ <DISP IACRG; Interrogation of IACHASTA-MET registration

Mount MO in MOD-0

CP113D
/ <INIT MO: VSN=<mo-no>, MOD=0, CD=ISO;

<EDIT MET: TYPE=IACMET;

<TRANS FILE: FILE=CA.IR., VSNR=<mo-no>, COPMOD=POST;

<DISP FILE: VSN=<mo-no>;

<RSET MO:MOD=0;

Remove MO from MOD-0 and label it

7-10 P30305-X1118-G503-01-7618
7.10.4. Saving Security Files / CP113D
Save security files SE./SA.ACTION, OP.ACTION, PW.LOG and SJ.SECDATA, if necessary.

CP113D
/ <DISP FILE;

Mount MO in MOD-0

CP113D
/ <INIT MO: VSN=<mo-no>, MOD=0, CD=EBC;

<TRANS FILE: FILE=<file-name>, VSNR=<mo-no>, COPMOD=SSWF;

<DISP FILE: VSN=<mo-no>;

<RSET MO:MOD=0;

Remove MO from MOD-0 and label it

7.10.5. Saving CA Files for Meter Accounting / CP113D


Statistic and trunk meters in the files CA.ST.UCHA and CA.TR.UCHA have to be saved for post
processing as account files.
Subscriber meters in the files CA.SU.UCHA and CA.TF.UCHA may be saved as account files
too, but they can also be saved as regeneration files for regeneration of meters in the new
APS.

CP113D
/ <DISP EXDDAT; Interrogation of MET types
<DISP FILE: FILE=CA.; and files, no files CA.UCHA.REL
or CA.UCHA.NEW available

Mount MO in MOD-0

CP113D
/ <INIT MO: VSN=<mo-no>, MOD=0, CD=EBC;

<EDITMET: TYPE=METSUB, FILE=CA.SU.CHA.99, FUNC=ACCOUNT, ...;


<EDIT MET:TYPE=<all other types>,FILE=CA.<xx>.CHA.99,FUNC=ACCOUNT, ...;

<TRANS FILE: FILE=CA., VSNR=<mo-no>, COPMOD=SSWF;

P30305-X1118-G503-01-7618 7-11
CP113D
/ <DISP FILE: VSN=<mo-no>;

<RSET MO:MOD=0;

Remove MO from MOD-0 and label it

7.10.6. Saving CA Files for Meter Regeneration / CP113D


If charge meters have to be transfered to APS V17/CCNC, the meters must be saved in form of
regeneration files in APS V11. With command file ”CF.11.REGMEMOG503” the regeneration
files CA.SU.APS.99 and CA.TF.APS.99 for subscriber and S130 meters will be generated and
saved to MO in MOD-0.

CP113D
/ <DISP FILE:FILE=CA.; Interrogation of files

Print out some meters count for spot checks after meter regeneration:

CP113D
/ <DISP MET: TYPE=METSUB, DN=<dn-number>&&<dn-number>, LAC=X;
or
<DISP MET: TYPE=METSUB, DN=X, LAC=X;

<STOP DISP: JN=<job-no>;

<DISP MET: TYPE=METTFS, SDN=<sdn-number>;

Start creation of regeneration files:

Mount MO in MOD-0

CP113D
/ <STAT SSP; MTD-0 / MOD-0 in ACT
<EXEC CMDFILE: FILE=CF.11.REGMEMOG503;

<RSET MO:MOD=0;

Remove MO from MOD-0 and label it

7-12 P30305-X1118-G503-01-7618
7.11. Regeneration of Charge Meters / CP113E
Regeneration of charge meters from APS V11 in APS V17/CCNC.

Mount MO in MOD-0

CP113E

/ <DACT FNS: FNS=CA;


<TRANS FILE: FILE=CA.,VSNS=<mo-no>, MODE=CRD;
<SAVE MET;
<REG MET: FILE=CA.SU.APS.99, TYPE=METSUB; For subscriber meter
<REG MET: FILE=CA.<xx>.APS.99, TYPE=<all other types>;
<SAVE MET;
<ACT FNS: FNS=CA;

<RSET MO: MOD=0;

Remove MO MOD-0

Comparing regenerated meter readings:

CP113E

/ <DISP MET: TYPE=METSUB, DN=<dn-number>&&<dn-number>, LAC=X;

or

<DISP MET: TYPE=METSUB, DN=X, LAC=X;


<STOP DISP: JN=<job-no>;
<DISP MET: TYPE=METTFS, SDN=<sdn-number>;

Compare meter readings from V11 with those of V17/CCNC

Note:
Additional meters may exist in APS V17/CCNC after activation of call processing

P30305-X1118-G503-01-7618 7-13
7.12. Stop Installation Recovery / CP113D

Press BOOT key on BAP-0

! System messages:

IPL113: MANUAL START - CURRENT CONFIGURATION


UNIT STATUS TEST
********************************************
BAP-0 MASTER NO TEST RUN
BAP-1 UNA
etc.

IPL113: ENTER PARAMS


TO DIAGNOSE MEMORY : "DIAG;"
TO FORMAT MEMORY : "FORMAT;"
TO CONTINUE : ";ETX"

CP113D

IPL113: MANUAL START ENTER PARAMS


TO START APS MANUALLY :"MANUALLY;"
TO START INSTALLAT.RECOV.:"INSTALLATION;"
TO START UTILITY(MONITOR):"UTILITY;"
TO STOP INITIAL START :"STOP;"
TO START APS AUTOMATICALLY:";ETX"

CP113D

STOP;

! INITIAL RECOVERY STOPPED

Switch off power from BAP-0

7-14 P30305-X1118-G503-01-7618
7.13. Diagnosis of the Periphery / CP113E
Diagnosis of the new cabling between CP113E and MB, CCG, SYP and CCNC.

Diagnose periphery in a low traffic period.

7.13.1. Diagnosis of the MB


The command file “CF.17.DIAGMB0G503 “ and “CF.17.DIAGMB1G503” for the diagnosis of
the MB-0 and MB-1 fit a system with capacity stage up to DE54. Each MB side is diagnosed
from CP-0 as well as from CP-1 by the following command file.

CP113E

/ <STAT MB;
<STAT SN;
<STAT CCNC: UNIT=MUXM-X;
! MB-0 and MB-1 in ACT Configure MB if necessary
SN-0 in ACT or STB, SN-1 in STB or ACT Configure SN if necessary
MUXM-0,1 and MUXM-10,11 in ACT or PLA Configure MUXM if necessary

CP113E

/ <EXEC CMDFILE: FILE=CF.17.DIAGMB0G503; Runtime about 8 min

! Please ignore error message if IOPMB is not created.


MB-0 in ACT, MB-1 in ACT

Wait 3 minutes for the synchronization of the SN.

CP113E

/ <EXEC CMDFILE: FILE=CF.17.DIAGMB1G503; Runtime about 8 min

! Please ignore error message if IOPMB is not created.


MB-0 in ACT, MB-1 in ACT

Wait 3 minutes for the synchronization of the SN.

P30305-X1118-G503-01-7618 7-15
7.13.2. Diagnosis of the SN
CP113E

/ <STAT SN;

! SN-0 in ACT or STB, SN-1 in STB or ACT

CP113E

/ <CONF SN:SN=<sn in stb>,OST= MBL; Configure SN in STB to MBL


<DIAG SN:SN=<sn in mbl>,TA=CHALL;
<CONF SN:SN=<sn in mbl>,OST= STB;

Wait 3 minutes for the synchronization of the SN

CP113E

/ <CONF SN:SN=<second sn>,OST= STB;


<CONF SN:SN=<second sn>,OST= MBL;
<DIAG SN:SN=<second sn>,TA=CHALL;
<CONF SN:SN=<second sn>,OST= STB;
<STAT SN;

! SN-0 in STB or ACT, SN-1 in ACT or STB

7-16 P30305-X1118-G503-01-7618
7.13.3. Check of CCG - IOPMB Connection
Check if CCGs remain in status active, when configuring the corresponding IOPMBs.

CP113E

/ <STAT CCG;

! CCG-0 in ACT or STB, CCG-1 in STB or ACT

CP113E

/ <CONF IOP:IOP=IOPMB-40,OST=MBL;

Wait 3 minutes if CCG-0,1 are still active

CP113E

/ <STAT CCG;
<CONF IOP:IOP=IOPMB-40,OST=ACT;

<CONF IOP:IOP=IOPMB-41,OST=MBL;

Wait 3 minutes if CCG-0,1 are still active

CP113E

/ <STAT CCG;
<CONF IOP:IOP=IOPMB-41,OST=ACT;

7.13.4. Check of SYPC - IOPMB Connection


Check if SYP remains in status active, when configuring the corresponding IOPMBs.

CP113E

/ <STAT SYP;

! SYP in ACT

CP113E

/ <CONF IOP:IOP=IOPMB-42,OST=MBL;

Wait 3 minutes if SYP is still active

P30305-X1118-G503-01-7618 7-17
CP113E

/ <STAT SYP;
<CONF IOP:IOP=IOPMB-42,OST=ACT;
<CONF IOP:IOP=IOPMB-43,OST=MBL;

Wait 3 minutes if SYP is still active

CP113E

/ <STAT SYP;
<CONF IOP:IOP=IOPMB-43,OST=ACT;

7.13.5. Diagnosis of CCNC


CP113E

/ <STAT CCNC:UNIT=CCNP-X;

! CCNP-0 in STB, CCNP-1 in ACT

CP113E

/ <CONF CCNC:UNIT=CCNP-1,OST=ACT; Configure CCNP-1 to ACT, if necessary

<EXEC CMDFILE:FILE=CF.17.DIAGCCNG503; Runtime about 30 min

7.14. Deleting Command Files / CP113E


CP113E

<DEL FILE: FILE=CF.17.;


<DEL FILE: FILE=CA.SU.APS.99;
<DEL FILE: FILE=CA.TF.APS.99;

7.15. Removing the MP

Remove the Maintenance Panel MP from BAP-0, BAP-1 and DCC

7-18 P30305-X1118-G503-01-7618
7.16. Setting the Upgrade Option
The upgrade option must be set back from “SPECIAL2“ to “NORMAL“. All SCIs will now be
written into file SY.VSD.BACKUP only.

CP113E

/ <SET UPGRDOPT:OPSTAT=NORMAL;

7.17. Starting Jobs / CP113E


All jobs deactivated during the upgrade procedure are to be reactivated:

CP113E

/ <DISP TRAMORD:STATUS=ALL; Display traffic jobs


<DISP CFTJOB; ”
<DISP JOB; ”
<DISP TJOB; ”
<DISP TSTJOB:JN=<no>; ”
<DISP TSTSCHED:SCHED=X,FULL=YES; ”

Start jobs for traffic measurement, traffic structure, time jobs, command time
jobs etc

7.18. Saving APS V17/CCNC / CP113E

Save the current APS on MOD according to the procedure SW 260 in


MMN:SW113 (quarterly saving) or use project-specific command file

7.19. Casino Outage Report

In order to improve the quality standards of System Upgrade Processes and so as to be able to
react more quickly to project problems which arise in relation to System Upgrades, the Outage
Report must be compiled for every completed upgrade process in each exchange. If Casino is
not available, the responsible TAC2 has to be contacted.

Fill out outage report

END OF PROCEDURE

P30305-X1118-G503-01-7618 7-19
This page was left intentionally blank!

7-20 P30305-X1118-G503-01-7618
8. INTERRUPTING THE UPGRADE PROCEDURE
If the startup of CP113E is not successful or the check of the APS V17/CCNC CP113E system
reveals deficiencies, a Fallback to the CP113D has to be executed.

Note:
Chapters 8.1 up to 8.4 have to be omitted if the recoveries fail.

8.1. Blocking Subscriber Entries / CP113E


CP113E

/ <DISP UPGRDOPT;

UPGRADE OPTIONS DATA


FSU BLKSCI OPSTAT
----------------------------------------
NO NO NORMAL

CP113E

/ <SET UPGRDOPT: BLKSCI=YES,OPSTAT=SPECIAL2;

8.2. Deactivating Links / CP113E

8.2.1. Deactivation of CSC-Links / CP113E

Save charge files via CSC-link if necessary

CP113E

/ <STAT SSP;
<DISP FILETRF:JN=X; If no transmission is in progress

<EXEC CMDFILE:FILE=CF.17.PLACSCG503; deactivate all CSC-links

P30305-X1118-G503-01-7618 8-1
8.2.2. Deactivation of X25-Links / CP113E

Save charge files via X25-link if necessary

CP113E

/ <STAT SSP;

<DISP FILETRF:JN=X; If no transmission is in progress

<EXEC CMDFILE:FILE=CF.17.PLAX25G503; deactivate all X25-links

8.3. Saving Logfile / CP113E


Note:
To be executed, if the APS V17/CCNC was in service for such a long time, that database
modifications must be taken into account.

Attention:
The database conversion from V17/CCNC back to V11 is not supported by the REFORM
tool. It must be made manually if it is necessary. A prerequisite is the knowledge of the
conversion rules. So the LG-logfile has to be checked, if it makes sense to incorporate
the V17/CCNC logfile into the V11 APS.

Switching the LOG function:

CP113E

/ <RSET LOG;

<DISP FILE: FILE=LG.; Interrogation of LG-logfiles

<STAT LOG;

<MOD LOGFILE: FILE=<file-name>,SIZE=24;

<DISP FILETEXT:FILE=LG.<terminated logfile>.A1; Display of LG-logfile for entries

8-2 P30305-X1118-G503-01-7618
Saving LG-files:

Mount MO in MOD-0

CP113E

/ <INIT MO: VSN=LOGTAP, CD=EBC, MOD=0;

<TRANS FILE: FILE=LG.<file-name>.A1,VSNR=<mo-no>,COPMOD=SSWF;

<DISP FILE: VSN=<mo-no>;

<RSET MO: MOD=0;

Remove MO from MOD-0 and hold it ready for the transfer of the logfiles and
manual conversion of the LG-logfile from V17/CCNC to V11.

8.4. Updating Charge Files on Disk / CP113E


CP113E

/ <EXEC CMDFILE:FILE=CF.17.UPDFILEG503;

! Check if all available files are updated. If not enter command


“<TRANS BUFFER:TYPE=<type>;” for missing IA type

8.5. Stopping System V17/CCNC / CP113E


CP113E

/ <STAT SSP;

! BAP-0 is SPR or MAS, BAP-1 is MAS or SPR

CP113E

/ <CONF BAP:BAP=<spr>,OST=MBL;

Switch off power from BAP-<spr>

Press BOOT key on CMYE-<mas>

P30305-X1118-G503-01-7618 8-3
CP113E

/ ;
STOP;

I N I T I A L S T A R T S T O P P E D

Switch off power from BAP-<mas>

8.6. Disconnection of MB/CCG/CCNP-1 and SYPC from CP113E


- Connecting cables from CP113E,R:CP113E, F:PIOP-0,1,2,3 to R:MB/CCG(B)/R:MB(B),
MB-1,3,5,7 and CCG-1, see Chapter 12.4.1.1

Unplug cables on side MB-1,3,5,7 and CCG-1 only:

- VAR 3012: IOP-0,1 - MB-1 (4 cables) Stage up to DE54

- VAR 3011: IOP-0,1 - CCG-1 (4 cables)

- VAR 3013: IOP-0,1 - MB-3 (4 cables) Stage DE52,54

- VAR 3014: IOP-2,3 - MB-5 (4 cables) Stage DE54

- VAR 3014: IOP-2,3 - MB-7 (4 cables) Stage DE54

- Connecting cables from CP113E, R:CP113E, F:PIOP-0,1 to R:MB/CCG(B), SYPC, see


Chapter 12.4.2

Unplug cables on side SYPC only:

- VAR 3100: IOP-0,1 - SYPC (4 cables)

- Connecting cables from CP113E, R:CP113E, F:PIOP-0,1,2,3 - R:CCNP, CCNP-1, see


Chapter 12.4.3.1

Unplug cable on side CCNP-1 only:

- VAR 3101: IOP-0,1 - CCNP-1 (4 cables) Stage up to DE52

- VAR 3102: IOP-2,3 - CCNP-1 (4 cables) Stage DE54

8-4 P30305-X1118-G503-01-7618
8.7. Disconnection of MB/CCG/CCNP-0 from CP113E
- Connecting cables from CP113E, R:CP113E, PIOP-0,1,2,3 to R:MB/CCG(B)/R:MB(B), MB-
0,2,4,6 and CCG-0, see Chapter 12.4.1.2

Unplug cables on side MB-0,2,4,6 and CCG-0 only:

- VAR 3012: IOP-0,1 - MB-0 (4 cables) Stage up to DE54

- VAR 3011: IOP-0,1 - CCG-0 (4 cables)

- VAR 3013: IOP-0,1 - MB-2 (4 cables) Stage DE52,54

- VAR 3014: IOP-2,3 - MB-4 (4 cables) Stage DE54

- VAR 3014: IOP-2,3 - MB-6 (4 cables) Stage DE54

- Connecting cables from CP113E, R:CP113E, F:PIOP-0,1,2,3 to R:CCNP, CCNP-0, see


Chapter 12.4.3.2

Unplug cables on side CCNP-0 only:

- VAR 3101: IOP-0,1 - CCNP-0 (4 cables) Stage up to DE52

- VAR 3102: IOP-2,3 - CCNP-0 (4 cables) Stage DE54

P30305-X1118-G503-01-7618 8-5
8.8. Connection of MB/CCG/CCNP-0 to CP113D
- Connecting cables from CP113D, R:DEV D0, IOP-0,1,2,3 to R:MB/CCG(B)/R:MB(B),
MB-0,2,4,6 and CCG-0, see Chapter 12.4.1.2

Plug in cables on side MB-0,2,4,6 and CCG-0 only:

- VAR 064 up to 067: IOP-0,1 - MB-0 (4 cables) Stage up to DE54

- VAR 064 up to 067: IOP-0,1 - CCG-0 (4 cables)

- VAR 064 up to 067: IOP-0,1 - MB-2 (4 cables) Stage DE52,54

- VAR 066 up to 067: IOP-2,3 - MB-4 (4 cables) Stage DE54

- VAR 066 up to 067: IOP-2,3 - MB-6 (4 cables) Stage DE54

- Connecting cables from CP113D, R:DEV D0, F:IOP-0,1,2,3 to R:CCNP, F:CCNP-0, see
Chapter 12.4.3.2

Plug in cables on side CCNP-0 only:

- VAR 048: IOP-0,1 - CCNP-0 (4 cables) Stage up to DE52

- VAR 049: IOP-2,3 - CCNP-0 (4 cables) Stage DE54

8-6 P30305-X1118-G503-01-7618
8.9. Connection of MB/CCG/CCNP-1 and SYPC to CP113D
- Connecting cables from CP113D, R:DEV D0, IOP-0,1,2,3 to R:MB/CCG(B)/R:MB(B),
MB-1,3,5,7 and CCG-1, see Chapter 12.4.1.1

Plug in cables on side MB-1,3,5,7 and CCG-1 only:

- VAR 064 up to 067: IOP-0,1 - MB-1 (4 cables) Stage up to DE54

- VAR 064 up to 067: IOP-0,1 - CCG-1 (4 cables)

- VAR 064 up to 067: IOP-0,1 - MB-3 (4 cables) Stage DE52,54

- VAR 066 up to 067: IOP-2,3 - MB-5 (4 cables) Stage DE54

- VAR 066 up to 067: IOP-2,3 - MB-7 (4 cables) Stage DE54

- Connecting cables from CP113D, R:DEV D0, F:IOP-0,1 to R:MB/CCG(B), F:SYPC, see
Chapter 12.4.2

Plug in cables on side SYPC only:

- VAR 044: IOP-0,1 - SYPC (4 cables)

- Connecting cables from CP113D, R:DEV D0, F:IOP-0,1,2,3 to R:CCNP, F:CCNP-1, see
Chapter 12.4.3.1

Plug in cables on side CCNP-1 only:

- VAR 048: IOP-0,1 - CCNP-1 (4 cables) Stage up to DE52

- VAR 049: IOP-2,3 - CCNP-1 (4 cables) Stage DE54

P30305-X1118-G503-01-7618 8-7
8.10. Installation Recovery of V11/ CP113D
Attention:
Before starting the recovery, the periphery has to configured to PLA to secure loading the LTGs
via both message channels.

CP113D

Switch on power to BAP-0

! As soon as the trackpoint A885 on the MP display disappears, the BOOT key
on BAP-0 must be pressed.

Press BOOT key on BAP-0

CP113D

FORMAT;

INS;

IOC-0;

11xxxxxxx;

! After the display on IOPTA-0,1 changes to “AC“ the APS can be started as follows:

OMT-SW: XENIX OMT-SW: UNIX

CP113D CP113D

Press the request key F1 <START FCP;

PLEASE ENTER USERID PLEASE ENTER USERID


<user id> <user id>

PLEASE ENTER CURRENT PASSWORD PLEASE ENTER CURRENT PASSWORD


<password> <password>

CP113D

<START FCP;

Message: STARTFCP EXEC´D

8-8 P30305-X1118-G503-01-7618
CP113D

<START OM;

<START SFGSW;

<DISP TIME; Time is correct and secure

<ENTR TIME:DATE=<y-m-d>,TIME=<h-min-s>,WD=<wd>; If time is insecure


<CORR TIME:MODE=SECURE;

<START CSWD;

8.11. Configuration of the periphery.


MB and SN are configured to PLA using command file ”CF.11.MBSNPLAG503”:

CP113D

<EXEC CMDFILE:FILE=CF.11.MBSNPLAG503;

Switch on power to BAP-1

8.12. Ending the Installation Recovery of APS V11


CP113D

<END INSTALL;

8.13. Startup of APS V11 with ISTART2F


CP113D

<RECOV SYSTEM: LEVEL=ISTART2F;

! A manual Startup ISTAT2F with LTG loading is performed.

P30305-X1118-G503-01-7618 8-9
8.14. System Status Inquiry / CP113D

OMT-SW: XENIX OMT-SW: UNIX

CP113D CP113D

/ Press the request key F1 / <STAT SSP;

PLEASE ENTER USERID PLEASE ENTER USERID


<user id> <user id>

PLEASE ENTER CURRENT PASSWORD PLEASE ENTER CURRENT PASSWORD


<password> <password>

CP113D

/ <STAT SSP;

Message: STATSSP EXEC´D

CP113D

/ <STAT LOG;
<SET LOG:FILE=<logfile-name>,SIZE=24;

<EXEC CMDFILE:FILE=CF.11.SYSTATG503;

8-10 P30305-X1118-G503-01-7618
! Required file states:
Update status is NORMAL
LOG state is ON
All files are available on both disks
All files for activated charge, IA features are available, if not deleted
in Installation Recovery

! Required CP status:
BAP-0 = MAS or SPR BAP-1 = SPR or MAS
CAP-0...5 = ACT (If available)
IOC-0 = ACT IOC-1 = ACT
IOC-2 = ACT IOC-3 = ACT (DE54)
CMY-0 = ACT CMY-1 = ACT
BCMY-0 = ACT BCMY-1 = ACT
IOPMB-0 = ACT IOPMB-1 = ACT (CCNC)
IOPMB-32 = ACT IOPMB-33 = ACT (MB:DE4 -DE54)
IOPMB-34 = ACT IOPMB-35 = ACT (MB:DE52,DE54)
IOPMB-36 = ACT IOPMB-37 = ACT (MB:DE52,DE54)
IOPMB-38 = ACT IOPMB-39 = ACT (MB:DE54)
IOPMB-40 = ACT IOPMB-41 = ACT (CCG)
IOPMB-42 = ACT IOPMB-43 = ACT (SYP)
IOPMDD-0 = ACT IOPMDD-1 = ACT
IOPMTD-0 = ACT IOPMTD-1 = PLA
IOPSCDV-0 = ACT IOPSCDV-1 = ACT
IOPTA-0 = ACT IOPTA-1 = ACT
IOPLAU-0 = ACT IOPLAU-1 = ACT (X25LINK)
IOPLAU-2 = ACT IOPLAU-3 = ACT ”
MDD-0 = ACT MDD-1 = MBL
MTD-0 = ACT MTD-1 = PLA (If available)
OMT-0 = ACT OMT-1 = ACT
LAU-0 = ACT LAU-1 = ACT (X25LINK)
LAU-2 = ACT LAU-3 = ACT “
CSC-0 = PLA CSC-1 = PLA
etc

! Required status of periphery:

MB: MB-0 in ACT, MB-1 in ACT


SN: SN-0 in ACT/STB, SN-1 in STB/ACT
CCG: CCG-0 in ACT, CCG-1 in MBL
SYP: MBL
LTG: LTGs in ACT, CH0/CH1 in ACT/STB
DLUC-0,1: ACT
CCNC: CCNP-0 in ACT, CCNP-1 in MBL
MUXM-0,1 in ACT/ACT or PLA, MUXM-10,11 in ACT/UNA or PLA
NUCs in ACT, C7LINKs in ACT

Check the system states and configure to normal states if necessary, except
CCG/CCNP-1 and SYP

P30305-X1118-G503-01-7618 8-11
8.15. Unblocking Subscriber Controlled Imputs

CP113D

/ <EXEC CMDFILE: FILE=PA.11.B2925L2J;

8.16. Systemtest / CP113D

Test system according to test concept in Chapter 4.2

8.17. Incorporating Logfile / CP113D


Note:
To be executed only if a logfile exists from the CP113E and was transferred from MOD to MOD
via TACO and WinDISKUS.

Mount MO containing CP113E logfile in MOD-0

CP113D

/ <DACT FNS: FNS=LG;

<MOD LOGFILE: FILE=<logfile-name>,SIZE=24;

<DEL FILE: FILE=LG.;

<TRANS FILE: FILE= LG., VSNS=<mo-no>, MODE=CRD;

Preparation of transmitted logfile:

CP113D

/ <EXEC EDTS8;
*R LG.<logfile-name>.A1

Insert after <CMDFILE;

<SET CFOPT: ACKCFS=ERROR, DANCMD=EXEC, ACKREQ=POS;

Insert before <ENDFILE;

<RESET CFOPT;

8-12 P30305-X1118-G503-01-7618
Convert the logfile from V17/CCNC back to V11 command syntax

CP113D

/ *W LG.<logfile-name>.A1
*Y
*D&
*END

<EXEC CMDFILE: FILE=LG.<logfile-name>.A1, CHOL=Y; Syntax check logfile

<ACT IAOPT: BLBUFR=ADMREC; Suppression of AMA-Tickets

<SET UPDATE: STATUS=SIMUL;

CP113D

/ <EXEC CMDFILE: FILE=LG. <logfile-name>.A1;

<SET UPDATE: STATUS=NORMAL;


<DISP UPDATE; Update status is NORMAL
<CAN IAOPT: BLBUFR=ADMREC;

<ACT FNS: FNS=LG;


<RSET MO:MOD=0;

Remove MO from MOD-0

8.18. Checking the Charge Files / CP113D

8.18.1. Check and Creation of CA- and MS-Files


Check and create CA- and MS-files if necessary.

CP113D

/ <DISP EXDDAT; Interrogation of MET types


<DISP FILE: FILE=CA.; Interrogation of CA- and
<DISP FILE: FILE=MS.; MS-files

<SAVE MET:TYPE=METSUB,FUNC=FALLBACK,ZEROIN=Y; If meter type exists


<SAVE MET:TYPE=METSTAT,FUNC=FALLBACK,ZEROIN=Y; “
<SAVE MET:TYPE=METTR,FUNC=FALLBACK,ZEROIN=Y; “
<SAVE MET:TYPE=METSSUB,FUNC=FALLBACK,ZEROIN=Y; “

<DISP FILE: FILE=CA.;


<DISP FILE: FILE=MS.;
! All necessary CA- and MS-files available

P30305-X1118-G503-01-7618 8-13
8.18.2. Check and Creation of IA-Files
Check and create IA-files if necessary.

CP113D

/ <DISP IAFEAT;
<DISP FILE:FILE=IA.;

<ACT IAFEAT:TYPE=AMA,SIZE=<size>; <size>, see old APS


<ACT IAFEAT:TYPE=MAL,SIZE=<size>; “
<ACT IAFEAT:TYPE=MOB,SIZE=<size>; “
<ACT IAFEAT:TYPE=<type>,SIZE=<size>; “
etc.

<DISP FILE:FILE=IA.;

! All IA-files available

8.18.3. Check and Creation of IARSTAT-Files


Check and create IR-files if necessary.

CP113D

/ <DISP IARJOB;
<DISP FILE:FILE=IR.;

<REC IARSTAT:MTYPE=IARSTAT<x>; <x>=1,2,3,4, for each IARSTAT type used

<DISP FILE:FILE=IR.;

! All IARSTAT-files available

8.19. Restoring original Meter Saving Points / CP113D


If meter saving has been shifted to a uncritical time, the original value has to be restored.

CP113D

/ <DISP METSAV;

<ENTR METSAV:TIME=<hh-mm>,CHEKNO=<no>; See original value

8-14 P30305-X1118-G503-01-7618
8.20. Activating CCG-1/CCNP-1 and SYP / CP113D
CP113D

/ <CONF CCG:CCG=1,OST=STB;

<CONF CCNC:UNIT=CCNP-1,OST=STB;

<CONF SYP:OST=ACT;

8.21. Activation of MDD-1 / CP113D

Switch on power to MDD-1

CP113D

/ <CONF MDD:MDD=1,OST=ACT;

! Supervise the message “SYNCHRONIZING FROM MDD-0 TO MDD-1: FINISHED“, but


continue executing the procedure

8.22. Change over of Links

8.22.1. Change over of CSC-Links from CP113E to CP113D


Note:
To be executed only if CSC-links were switched over to CP113E.

Connecting cables R:CP113E, IOPUNI-x - CSC-links / Transmission equipment

CP113E

Unplug cables on side of the MODEM only

Connecting cables R:DEV D0, IOPSCDV-x - CSC-links / Transmission equipment

CP113D

Plug in cables on side of the MODEM only

P30305-X1118-G503-01-7618 8-15
Activation of CSC-links:

CP113D

/ <EXEC CMDFILE:FILE=CF.11.ACTCSCG503;

! All available CSC-links activated

CP113D

Test the CSC-links

8.22.2. Change over of X25-Links from CP113E to CP113D

Connecting cables R:CP113E, IOPLAU-x - X25-links / Transmission equipment

CP113E

Unplug cables on side of the MODEM only

Connecting cables R:DEV D0, IOPLAU-x - X25-links / Transmission equipment

CP113D

Plug in cables on side of the MODEM only

Activation of X25-links:

CP113D

/ <EXEC CMDFILE:FILE=CF.11.ACTX25G503;

CP113D

Test the X25-links

8-16 P30305-X1118-G503-01-7618
8.23. Start of the Installation Recovery / CP113E

CP113E

Switch on power to CMYE-0

! As soon as the trackpoint A885 on the MP display disappears, the BOOT key
on CMYE-0 must be pressed.

Press BOOT key on CMYE-0

CP113E

FORMAT;

INS;

IOC-0;

17xxxxxx;

##### BAP-0 IS LOADING APS - DISPLAY : xxxx #####

! After the system message “INSTALL RECOVERY INFORMATION....“ the APS can
be started as follows:

OMT-SW: XENIX OMT-SW: UNIX

CP113E CP113E

/ <Press the request key F1 / <START FCP;

PLEASE ENTER USERID PLEASE ENTER USERID


<userid> <userid>

PLEASE ENTER CURRENT PLEASE ENTER CURRENT


PASSWORD PASSWORD
<password> <password>

CP113E

/ <START FCP;

Message: STARTFCP EXEC´D

P30305-X1118-G503-01-7618 8-17
CP113E

/ <START OM;
<START SFGSW;
<START CSWD;
<DISP TIME; Time is secure

If time is insecure, enter time and date and set to secure:

CP113E

/ <ENTR TIME:DATE=<yy-mm-dd>, TIME=<hh-mm-ss>, WD=<wd>,


OFFSET=<x> - POS or NEG, SEASON=<zzz>;

<x>= 0....840, number of OFFSET minutes decimal (multiple of 15).


OFFSET is the time difference between Universal Time Clock
(UTC) and local time.
POSitive or NEGative is the OFFSET direction
<zzz>= STD Standard or
<zzz>= DST Daylight saving

CP113E

/ <MOD TIME:MODE=SECURE;

8.24. Starting Processes / CP113E


CP113E

/ <EXEC CMDFILE:FILE=CF.17.PROG503;

8.25. Saving Charge Files / CP113E

See and execute Chapter 7.10 if necessary.


In this case CP113D is CP113E and vice versa.

8.26. Stop Installation Recovery / CP113E


BAP-1 is powered off

CP113E

Press BOOT key on CMYE-0

Switch off power from BAP-0

8-18 P30305-X1118-G503-01-7618
8.27. Diagnosis of the Periphery / CP113D
Diagnose the old cabling between the old CP113E and MB, SN, CCG, SYPC and CCNC in a
low traffic period.

See and execute Chapter 4.5

8.28. Activating Routine Tests / CP113D


CP113D

/ <ALLOW SSPRT;
<INHIB SSPRT:TESTID=<test-id>; See available CP units

8.29. Deleting auxiliary Files / CP113D


CP113D

/ <DEL FILE:FILE=CF.11.;
<DEL FILE:FILE=PA.11.;

<DEL FILE:FILE=CA.SU.APS.99;
<DEL FILE:FILE =CA.TF.APS.99;

8.30. Saving of APS V11 / CP113D

Save the APS V11 by procedure SW 210 in manual MMN:SW (Quarterly Saving)

END OF FALLBACK PROCEDURE

P30305-X1118-G503-01-7618 8-19
This page was left intentionally blank!

8-20 P30305-X1118-G503-01-7618
9. PROJECT RELATED ITEMS

9.1. Downward-compatible HW/FW Modifications:


*** None ***

9.2. Not downward-compatible HW/FW Modifications:


*** None ***

P30305-X1118-G503-01-7618 9-1
This page was left intentionally blank!

9-2 P30305-X1118-G503-01-7618
10. ABBREVIATIONS
APS Application Program System
BAP Base Processor
BCMY Access Bus for Common Memory
BIOC Bus for Input/Output Control
CAP Call Processor
CBL Conditional Blocking
CCG Central Clock Generator
CCNC Common Channel Signaling Network Control
CMY Common Memory
CP Coordination Processor
CSC Central Service Channel
DCC Direct Current Converter
DCP Data Communication Processor
DF Distribution Frame
DIU Digital Interface Unit
DLU Digital Line Unit
DLUC Digital Line Unit Control
DSB Digital Switch Board
F:.... Frame: ....
FW Firmware
HW Hardware
IOC Input/Output Control
IOP Input/Output Processor
IOP:MB IOP for Message Buffer
IOP:TA IOP for Time and Alarm
IOP:UNI IOP Unified for O&M Devices
LAUB Line Adaptation Unit, Module B
LCUB Line Control Unit, Module B
LMY Local Memory
LTG Line Trunk Group
M:.... Module:....
MBL Maintenance Blocking
MCH Message Channel
MDD Magnetic Disk Device
MO Magneto Optical Disk
MOD Magneto Optical Disk Device
MT Magnetic Tape
MTD Magnetic Tape Device
MUT Mounting Unit
NSS Non-Switching System
OMT Operation and Maintenance Terminal
PIA Processor Interface and Arbiter
R:.... Rack:....
SN Switching Network
SPI Switching Periphery Interface
SS Switching System
SYP System Panel
V... Version ...

P30305-X1118-G503-01-7618 10-1
This page was left intentionally blank!

10-2 P30305-X1118-G503-01-7618
11. REFERENCES
/1/ Procedure Description
P30305-X1118-E137-**-7618
Database Regeneration V11
CP113

/2/ Procedure Description


P30305-X1118-E303-**-7618
Database Handling V9….V17 to V17
CP113

/3/ Procedure Description


P30305-X1118-G475-**-7618
Database Installation V17 (without FSU)
CP113

/4/ Instruction ICP-1000


P30305-Xxxxx-yyyy-**-7618
Instructions for Service and Maintenance: ICP-1000

/5/ Installation Guide


P30304-W2858-A010-01-76D1
Message Routing, Access Security
EWSD V13A

/6/ Operating Instructions


P30202-P32-A000-**-7619
EWSD
TACO

/7/ Operating Instructions


P30202-P7000-B102-**-7619
EWSD
R E F O R M V601

/8/ Operating Instructions WinDISKUS


See WinDISKUS Manual (dbtool\prglib\wdiskus\manual)

P30305-X1118-G503-01-7618 11-1
This page was left intentionally blank!

11-2 P30305-X1118-G503-01-7618
12. APPENDIX

12.1. CP113D

12.1.1. CP113D Racks for Capacity Stage up to DE54

MUT

IOP-0 C CMY-0 0 CAP 0 IOC-2 IOP-2 C


3
(F:IOP-0) D (F:CMY-0) (F:P/IOC-2) (F:IOP-2) D
IOP-1 C CMY-1 0 CAP 1 IOC-3 IOP-3 C
4
(F:IOP-1) D (F:CMY-1) (F:P/IOC-3) (F:IOP-3) D
0
6
MTD-0 (F:MI-0) (F:PI-0)
0
7
(F:MI-1) (F:PI-1)
BAP-0 IOC-0 0 CAP 2 CAP 3
9
MDD MDD (F:P/IOC-0) (F:P/IOC-4)
0 1 BAP-1 IOC-1 1 CAP 4 CAP 5
0
(F:P/IOC-1) (F:P/IOC-5)

R:DEV D0 R:CP113A R:CP113B R:DEV D1


(S30805-C2574- (S30805-C2573- (S30805-C2572- (S30805-C2574-X)
X/X100) X/X100) X/X100)

Capacity stage up to DE52, CAPs, without IOC-2,3

Capacity stage DE54, CAPs, IOC-2,3 and IOP-2,3

Assignment of processors:

R:CP113A: R:CP113B: Proc Group 0: Proc. 0-3


Proc. 0: BAP-0 Proc. 4: CAP-0 Proc. Group 1: Proc. 4-7
Proc. 1: IOC-0 Proc. 5: IOC-2 Proc. Group 2: Proc. 8-11
Proc. 2: BAP-1 Proc. 6: CAP-1
Proc. 3: IOC-1 Proc. 7: IOC-3
Proc. 8 - 11: CAP-2 - CAP-5

P30305-X1118-G503-01-7618 12-1
12.1.2. CP113D Frames for Capacity Stage up to DE52
- Frame equipping F:IOP-0 S30804-B2638-X in R:DEV D0, MUT 03 for stage up to DE52
IOPMB-0,32,40,42 for DE4,DE51
IOPMB-0,32,34,40,42 for DE52

DCC IOP IOP IOP IOP IOP IOP IOP IF IK IF IK DCC DCC
MS TA MB MB MB MB MB SC MTD DTD MDD DTD MR MS
40 42 32 34 0 DV

135 143 151 159 183

- Frame equipping F:IOP-1 S30804-B2638-X in R:DEV D0, MUT 04 for stage up to DE52
IOPMB-1,33,41,43 for DE4,DE51
IOPMB-1,33,35,41,43 for DE52

DCC IOP IOP IOP IOP IOP IOP IOP IF IK IF IK DCC DCC
MS TA MB MB MB MB MB SC MTD DTD MDD DTD MR MS
41 43 33 35 1 DV

135 143 151 159 183

12-2 P30305-X1118-G503-01-7618
12.1.3. CP113D Frames for Capacity Stage DE54
- Frame equipping F:IOP-0 S30804-B2638-X in R:DEV D0, MUT 03 for stage DE54
IOPMB-32,34,40,42

DCC IOP IOP IOP IOP IOP IOP IF IK IF IK DCC DCC


MS TA MB MB MB MB SC MTD DTD MDD DTD MR MS
40 42 32 34 DV

135 143 151 159

- Frame equipping F:IOP-1 S30804-B2638-X in R:DEV D0, MUT 04 for stage DE54
IOPMB-33,35,41,43

DCC IOP IOP IOP IOP IOP IOP IF IK IF IK DCC DCC


MS TA MB MB MB MB SC MTD DTD MDD DTD MR MS
41 43 33 35 DV

135 143 151 159

- Frame equipping F:IOP-2 S30804-B2638-X in R:DEV D1, MUT 03 for stage DE54
IOPMB-0,36,38

DCC IOP IOP IOP CLB DCC DCC


MS MB MB MB MR MS
36 38 0

101 151 159 183 225 313 331

- Frame equipping F:IOP-3 S30804-B2638-X in R:DEV D1, MUT 04 for stage DE54
IOPMB-1,37,39

DCC IOP IOP IOP CLB DCC DCC


MS MB MB MB MR MS
37 39 1

101 151 159 183 225 313 331

P30305-X1118-G503-01-7618 12-3
12.1.4. Allocation of log./phys. IOPMB/IOPLAU to Periphery

DE stage Log Plug pos. IOC B MB MBU: MBU: MBU: CCG SYP CCNP
4 5 5 IOP- IOC LTG LTG SGC
5 2 4 No
1
x x x 32 03C151 0 0 0 0-0 0-1 0-0
x x x 33 04C151 1 0 1 1-0 1-1 1-0
x x 34 03C159 0 1 2 0-2 0-3 0-1
x x 35 04C159 1 1 3 1-2 1-3 1-1
x 36 03C151 0 0 4 0-4 0-5 0-2
x 37 04C151 1 0 5 1-4 1-5 1-2
x 38 03C159 0 1 6 0-6 0-7 0-3
x 39 04C159 1 1 7 1-6 1-7 1-3
x x x 40 03C135 0 9 0
x x x 41 04C135 1 9 1
x x x 42 03C143 0 10 0
x x x 43 04C143 1 10 1
x x 0 03C183 0 4 0
x x 1 04C183 1 4 1
x x 0 03C183 2 4 0
x x 1 04C183 3 4 1
x x x LAU0 03C273/285 0 15
x x x LAU1 04C273/285 1 15
x x x LAU2 03C293/305 0 11
x x x LAU3 04C293/305 1 11

12-4 P30305-X1118-G503-01-7618
12.2. CP113E

12.2.1. CP113E Rack

R:CP113E

MUT
01
BREAKER-PANEL

81 #)
AD:RAL

03
F:EIOP 0

04
F:EIOP 1

05
F:BIOP (optionally)

06
FANTRAY

07
F:BPCE

08
F:EPCE

10 FAN-BOX

P30305-X1118-G503-01-7618 12-5
CAP 8 PEXE C101

12-6
IOC 2 PEXE C115
CAP 6 PEXE C129
CAP 4 PEXE C143
CAP 0 PEXE C157
IOC 0 PEXE C171
CAP 2 PEXE PEXE C185
CMYE 0 CMYE 0 CMYE 0 CMYE 0 C199
FOTX D209P2MB
FOTX D209P4MB
= Basic Extension

BAP 0 PEXE C219


CONE C243
BAP 1 PEXE C257
CMYE 1 CMYE 1 CMYE 1 CMYE 1 C275
FOTX D285P2MB
12.2.2. CP113E Frame F:BPCE

FOTX D285P4MB
CAP 3 PEXE PEXE C295
IOC 1 PEXE C309
CAP 1 PEXE C323
CAP 5 PEXE C337
CAP 7 PEXE C351
IOC 3 PEXE C365
CAP 9 PEXE C379

2
2
2
2
2
1

max. c.-number
2 + AMP)

(512MB)
16 (128MB)

(2048MB)
(1024MB)
(1024MB)

MI1:FOTX
F01:BPCE

M01:PEXE

comp. name
M04:CMYE
M03:CMYE
M02:CMYE
M01:CMYE

processor type
(CP113E Classic)
M03:PEXE (128MB

P30305-X1118-G503-01-7618
12.2.3. CP113E Frame F:EPCE

F02:EPCE (S30804-B2835-X)

= basic capacity

max. c.-number

comp. name
C125
C149
C191
C205
C219
C233
C253
C267
C281
C295
C343
C367
MDDE 0

MDDE 1

F02:EPCE
1
MODE

MODE

M01:MODE
2
MDDE
MDDE

M01:MDDE
2
F1)
F2)F2)

F1) MDDE for one FF (FastFile V3) user (EWSD classic only)
F2) MDDE for two FF (FastFile V3) users (EWSD classic only)

Note: This frame contains MDD’s and MOD’s.

P30305-X1118-G503-01-7618 12-7
12.2.4. CP113E Frame F:EIOP classic IOC 0 + 1

max. c.-number

comp. name
= basic capacity
DCCMD C101
C117
C129
C137
C149
C157
C169
C177
C189
C197
C209
C217
C229
C237
C245
C253
C261
C271
C279
C287
C295
C303
C311
C323
DCCMD C341
F01:EIOP
1
LCUB

LCUB

LCUB

LCUB

LCUB

LCUB
LAUB

LAUB

LAUB

LAUB

LAUB

LAUB

M01:IOP:SCDP
IOP:UNI 6
IOP:UNI
IOP:UNI

IOP:UNI
M01:IOP:UNI
IOPMB 4

IOPMB
IOPMB
IOPMB

IOPMB
MI1:IOPMB
5

IOPTA
M01:IOPTA
1
IOPUNI2
IOPUNI2
IOPUNI2

IOPUNI2

M02:IOPUNI2
DCCMD 4

M01:DCCMC
1
11) 11) 10) 8) 6) 5) 4) 3) 2) 1)12)
B) C) C A)
A1)

Explanations:
1) IOPTA, only in IOP frames connected to IOC 0 and 1: system clock and radio clock
connection
2) IOPMB, only in IOP frames connected to IOC 0 and 1: conn. of CCG
3) IOP:UNI, only in IOP frames connected to IOC 0 and 1: conn. of MDD und MOD (in F:EPCE),
NetM-Boot,2 interfaces V.24/V.28, X.21/V.11
4) IOPMB, only in IOP frames connected to IOC 0 and 1: SYPC/PROFIBUS
5) 6) IOPMB connected at MB(B)

mounting location
Exchange size M:IOPMB placed in
M:IOPMB
SN:63LTG / 1x in F:EIOP 0 (IOC 0) C279
SN:126LTG 1x in F:EIOP 1 (IOC 1)
SN:252LTG 2x in F:EIOP 0 (IOC 0) C279 + C271
2x in F:EIOP 1 (IOC 1)
SN:504LTG 2x in F:EIOP 0 (IOC 0) C279 + C271
2x in F:EIOP 1 (IOC 1
2x in F:BIOP left side (IOC 2) C149 + C157
2x in F:BIOP right side (IOC 3) C281 + C289

8) IOPMB, only in IOP frames connected to IOC 0 and 1: connection of CCNP only in DE4, 51
and 52 (for connection of CCNP to DE54 see F:BIOP classic with MBB)
10) IOP:UNI, only in IOP frames connected to IOC 0 and 1: connection of 3 interfaces V.24/V.28,
X.21/V.11

12-8 P30305-X1118-G503-01-7618
11) LAUB+LCUB, connection of 2 X.25-IF; distribute in both F:EIOP equally for reasons of failure!
12) This 3. DCCMD is necessary, if more than 160 Watt power are necessary; here the
values for calculation:
- IOPMB 10W
IOP:UNI/IOPUNI2 18W
- LCUB 20W (LAUB takes no power from DCC)
- IOPTA 25W

A) IOPUNI2 Boot-IOP for conn. of MDDE and MODE, NetM-Boot with V.24/V.28 and 2 further
interfaces: V.24/V.28 but only 1 of the 2 interf. with V.24/V.11 (cable P2):
these modules in IOP 0+1 must be same type (both M:IOP:UNI or both M:IOPUNI2).

A1) IOPUNI2 CP Bulk Data File Transfer (Fast File new) for EWSD classic, connection of one
Ethernet Interface (for Fast File transfer to NetM-Boot); additional to the V.24/V.28 (NetM-
Boot) to Boot-IOP M:IOPUNI2 in IOP 1

B) IOPUNI2 for connection of 3 interfaces: V.24/V.28, but only 2 of the 3 interf. with V.24/V.11
(cable P1, P2)

C) IOPUNI2 for connection of 3 interfaces: V.24/V.28, but only 1 of the 3 interf. with V.24/V.11
(cable P2)

Note:
The F:EIOP frame can contain up to 16 input / output processors (IOP). For redundancy reasons
always two F:EIOP have to be installed

P30305-X1118-G503-01-7618 12-9
12.2.5. CP113E Extension Frame F:PIOP classic IOC 2 + 3

(left side connection IOC 2, right side IOC 3)


Not for new planning: no more IOC 2 +3 necessary with MB(D) in classic; this was an
old projecting rule based on exchange size (DE4, DE51, DE52 and DE54).

max. c.-number

comp. Name
= basic capacity
DCCMD C101
C117
C125
C133
C141
C149
C157
C167
C175
C183
C191
DCCMD C203
DCCMD C233
C249
C257
C265
C273
C281
C289
C299
C307
C315
C322
DCCMD C335
F01:BIOP
1
LCUB

LCUB

LCUB

LCUB
LAUB

LAUB

LAUB

LAUB

M01:IOP:SCDP
4
IOPMB
IOPMB
IOPMB

IOPMB
IOPMB
IOPMB
MI:IOPMB
6
IOP:UNI

IOP:UNI
M01:IOP:UNI
2
IOPUNI2

IOPUNI2

M02:IOPUNI2
2
11)11) 7) 7) 8) 10) 11)11) 7) 7) 8)10)
B) B)

Explanations:
7) IOPMB, only in IOP frames connected to IOC 2 and 3: additional if MB(D) is connected with
DE54 (IOP:MB for DE4, DE51 and DE52; in F:EIOP, item 5) and 6))
8) IOPMB, only in IOP frames connected to IOC 2 and 3: connection of CCNP if MB(D) is
connected with DE54 only (alternative to IOP:MB in F:EIOP classic IOC 0 + 1, item 8)
10) IOP:UNI, connection of 3 interfaces V.24/V.28, X.21/V.11
11) LAUB+LCUB, connection of 2 X.25-IF; distribute in F:BIOP left and right side equally for
reasons of failure!

B) IOPUNI2 for connection of 3 interfaces: V.24/V.28, but only 2 of the 3 interf. with V.24/V.11
(cable P1, P2)

12-10 P30305-X1118-G503-01-7618
12.2.6. Allocation of Log./Phys. IOP’s to the Periphery

DE type Log PIOP No Plug position IOC BIOC MB MBU: MBU: MBU: CCG SYP CCNC
4 IOP:MB LTG LTG SGC
51 52 54
x x x IOPMB-32 03C279 0 0 0 0-0 0-1 0-0
x x x IOPMB-33 04C279 1 0 1 1-0 1-1 1-0
x x IOPMB-34 03C271 0 1 2 0-2 0-3 0-1
x x IOPMB-35 04C271 1 1 3 1-2 1-3 1-1
x IOPMB-36 05C157 2 0 4 0-4 0-5 0-2
x IOPMB-37 05C289 3 0 5 1-4 1-5 1-2
x IOPMB-38 05C149 2 1 6 0-6 0-7 0-3
x IOPMB-39 05C281 3 1 7 1-6 1-7 1-3
x x x IOPMB-40 03C303 0 9 0 0-2 0-3 0-1 0
x x x IOPMB-41 04C303 1 9 1 1-2 1-3 1-1 1
x x x IOPMB-42 03C287 0 10 0 0-2 0-3 0-1 0
x x x IOPMB-43 04C287 1 10 1 1-2 1-3 1-1 1
x x IOPMB-0 03C261 0 2 0
x x IOPMB-1 04C261 1 2 1
x IOPMB-0 05C167 2 10 0
x IOPMB-1 05C299 3 10 1
x x x IOPUNI-0 03C295 0 12 0 0-2 0-3 0-1
x x x IOPUNI-1 04C295 1 12 1 1-2 1-3 1-1

P30305-X1118-G503-01-7618 12-11
12.3. Message Buffer MB(B)
Layout of MB(B) racks for capacity stage up to DE54:

The R:MB/CCG(B) S 30805-C2510-X is equipped with basic and extension frames.

Basic Rack Extension Rack

FU 1, 3, ............................ , 15 Fuse panel FU 1, 3, ............................., 15


FU 2, 4, ............................ , 16 MUT 01 FU 2, 4, ............................., 16

D MBU MBU C MBU CCG F:MB/CCG(B) D MBU MBU C MBU


C LTG SGC G LTG (A) MB-0 MB-4 C LTG SGC G LTG
DE51 C M C M
C 0-0 0-0 U 0-1 0 C 0-4 0-2 U 0-5
S X MUT 02 S X

D MBU MBU C MBU CCG F:MB/CCG(B) D MBU MBU C MBU


C LTG SGC G LTG (A) MB-1 MB-5 C LTG SGC G LTG
C M C M
C 1-0 1-0 U 1-1 1 C 1-4 1-2 U 1-5
S X MUT 03 S X

D I C R T T C D F:SYPC(A)
DE52 C O O M R X D C
C C M E M A E C DE54
DE54 C A C
R L MUT 05

D MBU MBU C MBU F:MB/CCG(B) D MBU MBU C MBU


C LTG SGC G LTG MB-2 MB-6 C LTG SGC G LTG
C M C M
C 0-2 0-1 U 0-3 C 0-6 0-3 U 0-7
S X MUT 08 S X

D MBU MBU C MBU F:MB/CCG(B) D MBU MBU C MBU


C LTG SGC G LTG MB-3 MB-7 C LTG SGC G LTG
C M C M
C 1-2 1-1 U 1-3 C 1-6 1-3 U 1-7
S X MUT 09 S X

R:MB/CCG(B R:MB(B) DE54

12-12 P30305-X1118-G503-01-7618
12.3.1. Frame Equipping MB(B)
Frame F:MB/CCG(B) S30804-B2641-X (basic with CCG-A)

MBU
1.MBU:LTG SGC 2.MBU:LTG CCG(A)
(0-0, 1-0) (0-0) (0-1,1-1) (0, 1)
(1-0)

DC T/ T T/ T/ MDM IOPC CG/ MDM T/ T/ CCG CCG CCG DCC


CCS RC /RC RC RC MUX RC RC D B xxA CR
(3) (2) (1) (0) (0) (1) (0) . . . (3)

LED
S1

1 19 25 31 37 43 49 55 62 68 86 98 104 111 121

Frame F:MB(B) S30804-B2641-X (extension without CCG-A)

MBU
1.MBU:LTG SGC 2.MBU:LTG
(0-2, 1-2) (0-1,1-1) (0-3,1-3)
(0-2,1-2)
(0-4, 1-4) (0-3,1-3) (0-5, 1-5)
(0-6, 1-6) (0-7, 1-7)

DC T/ T T/ T/ MDM IOPC CG/ MDM T/ T/


CCS RC /RC RC RC MUX RC RC not
(3) (2) (1) (0) (0) (1) (0) . . . (3) equipped

LED
S1

1 19 25 31 37 43 49 55 62 68 86

P30305-X1118-G503-01-7618 12-13
12.3.2. Notes on Cabling the MB(B)
Numbering system for the MB cable plug positions in the rack rear

R:MB/CCG(B)

MUT02 A MB-0/4
B
MUT03 A MB-1/5
B

MUT05 A SYPC
B

MUT08 A MB-2/6
B
MUT09 A MB-3/7
B
127..................................1

12.3.3. Notes on Cabling the CCNC


Numbering system for the CCNC cable plug positions in the CCNP rack rear

R:CCNP

MUT 02 A F:SILTD(A)
B

MUT 04 A F:SILTD(A)
B

MUT 06 A F:SILTD(A)
B

MUT 08 A F:CCNP(B)-0
B

MUT 10 A F:CCNP(B)-1
B

127.....................................1

12-14 P30305-X1118-G503-01-7618
12.4. Standard Cabling
The cabling in EWSD is divided in cable groups of which the following group is relevant for
the CP change from CP113D to CP113E using the existing MB(B) and CCNC as cabling
interfaces:

Cable group P: MB/CCG, CCNP, SYPC - IOP / CP113

The individual cable groups are divided into different variants VAR depending on the SN
capacity stage.
The variants required constitute the selection criteria for producing the cable-laying list CLL.

Documentation: Manual EWSD Standard Cabling A30808-X2929-X-*-32


The variants VAR specified in this procedure description refer to this document.

P30305-X1118-G503-01-7618 12-15
12.4.1. Cabling CP113D, CP113E - MB/CCG(B), Cable Group P

12.4.1.1. Connecting Cables IOP-0,1,2,3 - MB-1,3,5,7 and CCG-1


- Connecting cables in stage DE4, DE51, DE52, DE54

DE FROM CP113D FROM CP113E TO MB(B)


type R:DEV D0 R:CP113E R:MB/CCG(B)
4 52 IOP: F:IOP-0,1 IOP: F:EIOP MB F:MB/CCG(B)
51 54 MB Plug pos. MB Plug pos. CCG Plug pos.
x x 32 03C151 / P4 32 03C279 / P4 MB-1 03A046 *
x x 32 03C151 / P3 32 03C279 / P3 MB-1 03B046 *
x x 33 04C151 / P4 33 04C279 / P4 MB-1 03A052
x x 33 04C151 / P3 33 04C279 / P3 MB-1 03B052
x x 40 03C135 / P4 40 03C301 / P4 CCG-1 03A095 *
x x 40 03C135 / P3 40 03C301 / P3 CCG-1 03B095 *
x x 41 04C135 / P4 41 07C301 / P4 CCG-1 03A101
x x 41 04C135 / P3 41 07C301 / P3 CCG-1 03B101
x 34 03C159 / P4 34 03C271 / P4 MB-3 09A046
x 34 03C159 / P3 34 03C271 / P3 MB-3 09B046
x 35 04C159 / P4 35 04C271 / P4 MB-3 09A052 *
x 35 04C159 / P3 35 04C271 / P3 MB-3 09B052 *
x x 03C317 / P3 CCG-1 03B071 ** *
x x 04C317 / P3 CCG-1 03A071 **

* = Cross connecting cables


** = New clock cables

- Additional connecting cables only in stage DE54:

DE FROM CP113D FROM CP113E TO MB(B)


type R:DEV D0 R:CP113E R:MB(B):DE54
IOP: F:IOP-2,3 IOP: F:BIOP MB F:MB(B)
DE54 MB Plug pos. MB Plug pos. CCG Plug pos.
x 36 03C151 / P4 36 05C157 / P4 MB-5 03A046 *
x 36 03C151 / P3 36 05C157 / P3 MB-5 03B046 *
x 37 04C151 / P4 37 05C289 / P4 MB-5 03A052
x 37 04C151 / P3 37 05C289 / P3 MB-5 03B052
x 38 03C159 / P4 38 05C149 / P4 MB-7 09A046
x 38 03C159 / P3 38 05C149 / P3 MB-7 09B046
x 39 04C159 / P4 39 05C281 / P4 MB-7 09A052 *
x 39 04C159 / P3 39 05C281 / P3 MB-7 09B052 *

* = Cross connecting cables

12-16 P30305-X1118-G503-01-7618
12.4.1.2. Connecting Cables IOP-0,1,2,3 - MB-0,2,4,6 and CCG-0
- Connecting cables in stage DE4, DE51, DE52, DE54

DE FROM CP113D FROM CP113E TO MB(B)


type R:DEV D0 R:CP113E R:MB/CCG(B)
4 52 IOP: F:IOP-0,1 IOP: F:EIOP MB F:MB/CCG(B)
51 54 MB Plug pos. MB Plug pos. CCG Plug pos.
x x 32 03C151 / P2 32 03C279 / P2 MB-0 02A046
x x 32 03C151 / P1 32 03C279 / P1 MB-0 02B046
x x 33 04C151 / P2 33 04C279 / P2 MB-0 02A052 *
x x 33 04C151 / P1 33 04C279 / P1 MB-0 02B052 *
x x 40 03C135 / P2 40 03C303 / P2 CCG-0 02A095
x x 40 03C135 / P1 40 03C303 / P1 CCG-0 02B095
x x 41 04C135 / P2 41 04C303 / P2 CCG-0 02A101 *
x x 41 04C135 / P1 41 04C303 / P1 CCG-0 02B101 *
x 34 03C159 / P2 34 03C271 / P2 MB-2 08A046
x 34 03C159 / P1 34 03C271 / P1 MB-2 08B046
x 35 04C159 / P2 35 04C271 / P2 MB-2 08A052 *
x 35 04C159 / P1 35 04C271 / P1 MB-2 08B052 *
x x 03C317 / P2 CCG-0 02B071 **
x x 04C317 / P2 CCG-0 02A071 ** *

* = Cross connecting cables


** = New clock cables

- Additional connecting cables only in stage DE54:

DE FROM CP113D FROM CP113E TO MB(B)


type R:DEV D0 R:CP113E R:MB(B):DE54
IOP: F:IOP-2,3 IOP: F:BIOP MB F:MB(B)
DE54 MB Plug pos. MB Plug pos. CCG Plug pos.
x 36 03C151 / P2 36 05C157 / P2 MB-4 02A046
x 36 03C151 / P1 36 05C157 / P1 MB-4 02B046
x 37 04C151 / P2 37 05C289 / P2 MB-4 02A052 *
x 37 04C151 / P1 37 05C289 / P1 MB-4 02B052 *
x 38 03C159 / P2 38 05C149 / P2 MB-6 08A046
x 38 03C159 / P1 38 05C149 / P1 MB-6 08B046
x 39 04C159 / P2 39 05C281 / P2 MB-6 08A052 *
x 39 04C159 / P1 39 05C281 / P1 MB-6 08B052 *

* = Cross connecting cables

P30305-X1118-G503-01-7618 12-17
12.4.2. Cables CP113D, CP113E - SYPC(A), Cables Group P
DE- FROM CP113D FROM CP113E TO SYPC
Typ R:DEV D0 R:CP113E R:MB/CCG(B)
4 IOP: F:IOP-0,1 IOP: F:EIOP F:SYPC(A)
51 52 MB Plug pos. MB Plug pos. Plug pos.
x x 42 03C143 / P2 42 03C287 / P2 05A010
x x 42 03C143 / P1 42 03C287 / P1 05B010
x x 43 04C143 / P2 43 04C287 / P2 05A016
x x 43 04C143 / P1 43 04C287 / P1 05B016

Unplug and plug cable

12.4.3. Cable CP113D, CP113E - CCNC, Cable Group P

12.4.3.1. Connecting Cables IOP-0,1 - CCNP-1


- Connecting cables in stage DE4, DE51, DE52

DE- FROM CP113D FROM CP113E TO CCNC


Typ R:DEV D0 R:CP113E R:CCNP
4 IOP: F:IOP-0,1 IOP: F:EIOP F:CCNP
51 52 MB Plug pos. MB Plug pos. CCNP Plug pos.
x x 0 03C183 / P4 0 03C261 / P4 1 10A108 *
x x 1 04C183 / P4 1 04C261 / P4 1 10A114
x x 0 03C183 / P3 0 03C261 / P3 1 10B108 *
x x 1 04C183 / P3 1 04C261 / P3 1 10B114

Unplug and plug cable


* = Cross connecting cables

- Connecting cables in stage DE54:

DE- FROM CP113D FROM CP113E TO CCNC


Typ R:DEV D1 R:CP113E R:CCNP
IOP: F:IOP-2,3 IOP: F:BIOP F:CCNP
DE54 MB Plug pos. MB Plug pos. CCNP Plug pos.
x 0 03C183 / P4 0 05C167 / P4 1 10A108 *
x 1 04C183 / P4 1 05C299 / P4 1 10A114
x 0 03C183 / P3 0 05C167 / P3 1 10B108 *
x 1 04C183 / P3 1 05C299 / P3 1 10B114

Unplug and plug cable


* = Cross connecting cables

12-18 P30305-X1118-G503-01-7618
12.4.3.2. Connecting Cables IOP-0,1 - CCNP-0
- Connecting cables in stage DE4, DE51, DE52

DE- FROM CP113D FROM CP113E TO CCNC


Typ R:DEV D0 R:CP113E R:CCNP
4 IOP: F:IOP-0,1 IOP: F:EIOP F:CCNP
51 52 MB Plug pos. MB Plug pos. CCNP Plug pos.
x x 0 03C183 / P2 0 03C261 / P2 0 08A108
x x 1 04C183 / P2 1 04C261 / P2 0 08A114 *
x x 0 03C183 / P1 0 03C261 / P1 0 08B108
x x 1 04C183 / P1 1 04C261 / P1 0 08B114 *

Unplug and plug cable


* = Cross connecingt cables

- Connecting cables in stage DE54:

DE- VOM CP113D VOM CP113E ZUM CCNC


Typ R:DEV D1 R:CP113E R:CCNP
IOP: F:IOP-2,3 IOP: F:BIOP F:CCNP
DE54 MB Steckplatz MB Steckplatz CCNP Steckplatz
X 0 03C183 / P2 0 05C167 / P2 0 08A108
X 1 04C183 / P2 1 05C299 / P2 0 08A114 *
X 0 03C183 / P1 0 05C167 / P1 0 08B108
X 1 04C183 / P1 1 05C299 / P1 0 08B114 *

Unplug and plug cable


* = Cross connect cables

P30305-X1118-G503-01-7618 12-19
12.5. Command Files V11

12.5.1. Command File CF.11.ACTCSCG503


<CMDFILE;
/* CF.11.ACTCSCG503 */
/*
/***************************************************/
/* CF-NAME : CF.11.ACTCSCG503 */
/* */
/* PURPOSE : ACTIVATION OF CSC-LINKS */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* REMARKS : CSC-LINK 0..3 */
/***************************************************/
/*
//***************************************************
//* COMMAND FILE CF.11.ACTCSCG503 STARTED *
//***************************************************
//* ACTIVATION OF CSC-LINK 0..3 *
//***************************************************
//* IGNORE ERROR MESSAGES IF CSC-LINK *
//* IS NOT AVAILABLE *
//***************************************************
/*
<SET CFOPT: ACKCFS=ALL,DANCMD=EXEC,ACKREQ=POS;
/*
<ENTR ALMODE: HLIM=YES;
/*
<STAT SSP;
/*
<CONF CSC:CSC=0,OST=MBL;
<CONF CSC:CSC=1,OST=MBL;
<CONF CSC:CSC=2,OST=MBL;
<CONF CSC:CSC=3,OST=MBL;
<CONF CSC:CSC=0,OST=ACT;
<CONF CSC:CSC=1,OST=ACT;
<CONF CSC:CSC=2,OST=ACT;
<CONF CSC:CSC=3,OST=ACT;
/*
<STAT SSP;
//***************************************************
//* AVAILABLE CSC-LINKS MUST BE IN ACT *
//* IF NOT ACTIVATE CSC-LINKS *
//***************************************************
/*
<RESET CFOPT;
<ENDFILE;

12-20 P30305-X1118-G503-01-7618
12.5.2. Command File CF.11.ACTX25G503
<CMDFILE;
/* CF.11.ACTX25G503 */
/*
/***************************************************/
/* CF-NAME : CF.11.ACTX25G503 */
/* */
/* PURPOSE : ACTIVATION OF X25-LINKS */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* REMARKS : X25-LINK 0...7 */
/***************************************************/
/*
//***************************************************
//* COMMAND FILE CF.11.ACTX25G503 STARTED *
//***************************************************
//* ACTIVATION OF X25-LINK 0...7 *
//***************************************************
//* IGNORE ERROR MESSAGES IF X25LINK *
//* IS NOT AVAILABLE *
//***************************************************
/*
<SET CFOPT: ACKCFS=ALL,DANCMD=EXEC,ACKREQ=POS;
/*
<ENTR ALMODE: HLIM=YES;
/*
<STAT SSP;
/*
<CONF X25LINK:X25LINK=0,OST=MBL;
<CONF X25LINK:X25LINK=0,OST=ACT;
<CONF X25LINK:X25LINK=1,OST=MBL;
<CONF X25LINK:X25LINK=1,OST=ACT;
<CONF X25LINK:X25LINK=2,OST=MBL;
<CONF X25LINK:X25LINK=2,OST=ACT;
<CONF X25LINK:X25LINK=3,OST=MBL;
<CONF X25LINK:X25LINK=3,OST=ACT;
<CONF X25LINK:X25LINK=4,OST=MBL;
<CONF X25LINK:X25LINK=4,OST=ACT;
<CONF X25LINK:X25LINK=5,OST=MBL;
<CONF X25LINK:X25LINK=5,OST=ACT;
<CONF X25LINK:X25LINK=6,OST=MBL;
<CONF X25LINK:X25LINK=6,OST=ACT;
<CONF X25LINK:X25LINK=7,OST=MBL;
<CONF X25LINK:X25LINK=7,OST=ACT;
/*
<STAT SSP;
//***************************************************
//* AVAILABLE X25-LINKS MUST BE IN ACT *
//* IF NOT ACTIVATE X25-LINKS *
//***************************************************
/*
<RESET CFOPT;
<ENDFILE;

P30305-X1118-G503-01-7618 12-21
12.5.3. Command File CF.11.CPTESTG503
<CMDFILE;
/* CF.11.CPTESTG503 */
/*
/***************************************************/
/* CF-NAME : CF.11.CPTESTG503 */
/* */
/* LONG-NAME : TEST OF CP */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* PURPOSE : TEST OF CP, STAGE UP TO DE54 */
/* */
/* REMARKS : */
/***************************************************/
/*
//**************************************************/
//* COMMAND FILE CF.11.CPTESTG503 STARTED */
//**************************************************/
//**************************************************/
//* TEST OF CP113 */
//**************************************************/
/*
<SET CFOPT: ACKCFS=ALL, DANCMD=EXEC, ACKREQ=POS, OFF=16;
/*
<TEST BAP;
<SKIP CMD:LABEL=ERR,ON=32;
<COM BAP;
<SKIP CMD:LABEL=ERR,ON=32;
<TEST BAP;
<SKIP CMD:LABEL=ERR,ON=32;
<TEST IOC;
<SKIP CMD:LABEL=ERR,ON=32;
<TEST CMY;
<SKIP CMD:LABEL=ERR,ON=32;
<TEST BCMY;
<SKIP CMD:LABEL=ERR,ON=32;
<TEST IOPG:IOC=0;
<SKIP CMD:LABEL=ERR,ON=32;
<TEST IOPG:IOC=1;
<SKIP CMD:LABEL=ERR,ON=32;
<TEST CAP;
/*
//**************************************************/
//* IOC-2,3 ONLY IN CP-STAGE DE54 */
//**************************************************/
//* IGNORE ERROR MESSAGE IF STAGE IS < DE54 */
//**************************************************/
/*
<TEST IOPG:IOC=2;
<TEST IOPG:IOC=3;
/*
<RESET CFOPT;
//**************************************************/
//* CHECK IF ALL TESTS WERE SUCCESSFUL */
//**************************************************/
<ENDFILE;
/*
.ERR<STEP;
<SET CFOPT:ON=16, SCOPE=GLOBAL;

12-22 P30305-X1118-G503-01-7618
//**************************************************/
//* C O M M A N D N O T E X E C U T E D */
//**************************************************/
//* ELIMINATE FAULT AND ENTER NOT EXECUTED COMMANDS*/
//**************************************************/
<ENDFILE;

P30305-X1118-G503-01-7618 12-23
12.5.4. Command File CF.11.DIAGCCNG503
<CMDFILE;
/* CF.11.DIAGCCNG503 */
/*
/***************************************************/
/* CF-NAME : CF.11.DIAGCCNG503 */
/* */
/* PURPOSE : DIAGNOSIS OF CCNC */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* REMARKS : INITIAL STATUS: CCNP-0 IN STB */
/* CCNP-1 IN ACT */
/***************************************************/
/*
//***************************************************
//* COMMAND FILE CF.11.DIAGCCNG503 STARTE *
//***************************************************
//* DIAGNOSIS OF CCNC *
//***************************************************
/*
<SET CFOPT: ACKCFS=ALL, DANCMD=EXEC, ACKREQ=POS, OFF=16;
/*
//***************************************************
//* DIAGNOSIS OF CCNP-0 *
//***************************************************
/*
<STAT SSP;
<STAT CCNC:UNIT=CCNP-X;
/*
<CONF CCNC:UNIT=CCNP-0,OST=MBL;
<SKIP CMD: ON=32, LABEL=ERR;
<DIAG CCNC:UNIT=CCNP-0;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<CONF IOP:IOP=IOPMB-0,OST=MBL;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<DIAG CCNC:UNIT=CCNP-0;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<CONF CCNC:UNIT=CCNP-0,OST=STB;
<SKIP CMD: ON=32, LABEL=ERR;
<CONF CCNC:UNIT=CCNP-0,OST=ACT;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<CONF IOP:IOP=IOPMB-0,OST=ACT;
<SKIP CMD: ON=32, LABEL=ERR;
/*
//**************************************************
//* DIAGNOSIS OF CCNP-1 *
//**************************************************
/*
<STAT SSP;
<STAT CCNC:UNIT=CCNP-X;
/*
<CONF CCNC:UNIT=CCNP-1,OST=MBL;
<SKIP CMD: ON=32, LABEL=ERR;
<DIAG CCNC:UNIT=CCNP-1;
<SKIP CMD: ON=32, LABEL=ERR;

12-24 P30305-X1118-G503-01-7618
/*

P30305-X1118-G503-01-7618 12-25
<CONF IOP:IOP=IOPMB-1,OST=MBL;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<DIAG CCNC:UNIT=CCNP-1;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<CONF CCNC:UNIT=CCNP-1,OST=STB;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<CONF IOP:IOP=IOPMB-1,OST=ACT;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<STAT SSP;
<STAT CCNC:UNIT=CCNP-X;
/*
<RESET CFOPT;
//**************************************************************
//* PLEASE CHECK FOR FAILURES AND IF CCNPS ARE IN ACT/STB, *
//* IOPMB-0,1 IN ACT *
//**************************************************************
<ENDFILE;
/*
/*
.ERR<STEP;
<SET CFOPT: ON=16, SCOPE=GLOBAL;
//**************************************************************
//* C O M M A N D N O T E X E C U T E D *
//**************************************************************
//* ELIMINATE FAULT AND ENTER NOT EXECUTED COMMANDS *
//**************************************************************
<ENDFILE;

12-26 P30305-X1118-G503-01-7618
12.5.5. Command File CF.11.DIAGMB0G503
<CMDFILE;
/* CF.11.DIAGMB0G503 */
/*
/***************************************************/
/* CF-NAME : CF.11.DIAGMB0G503 */
/* */
/* PURPOSE : DIAGNOSIS OF MB-0 */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* REMARKS : FOR MB CAPACITY STAGE UP TO DE54 */
/***************************************************/
/*
//***************************************************
//* COMMAND FILE CF.11.DIAGMB0G503 STARTED *
//***************************************************
/*
<SET CFOPT: ACKCFS=ALL, DANCMD=EXEC, ACKREQ=POS, OFF=16;
/*
//***************************************************
//* DIAGNOSIS OF MB-0 *
//***************************************************
/*
<DISP EXDDAT;
<STAT SSP;
<STAT MB;
<STAT SN;
/*
<CONF MB: MB=0,OST=MBL;
<SKIP CMD: ON=32, LABEL=ERR;
<DIAG MB: MB=0,TA=ALL;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<CONF IOP:IOP=IOPMB-32,OST=MBL;
<SKIP CMD: ON=32, LABEL=ERR;
/*
//***************************************************
//* IOPMB-34 ONLY IN STAGE DE52,DE54 *
//***************************************************
/*
<CONF IOP:IOP=IOPMB-34,OST=MBL;
/*
//***************************************************
//* IOPMB-36,38 ONLY IN STAGE DE54 *
//***************************************************
/*
<CONF IOP:IOP=IOPMB-36,OST=MBL;
<CONF IOP:IOP=IOPMB-38,OST=MBL;
/*
<DIAG MB: MB=0,TA=ALL;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<CONF MB: MB=0,OST=ACT;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<CONF IOP:IOP=IOPMB-32,OST=ACT;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<CONF IOP:IOP=IOPMB-34,OST=ACT;

P30305-X1118-G503-01-7618 12-27
<CONF IOP:IOP=IOPMB-36,OST=ACT;

12-28 P30305-X1118-G503-01-7618
<CONF IOP:IOP=IOPMB-38,OST=ACT;
/*
<STAT SSP;
<STAT MB;
<STAT SN;
/*
<RESET CFOPT;
//******************************************************
//* PLEASE CHECK FOR FAULTS AND IF MB-0,1, SN-0,1 *
//* AND IOPMBS ARE IN ACT *
//******************************************************
<ENDFILE;
/*
.ERR<STEP;
<SET CFOPT: ON=16, SCOPE=GLOBAL;
//*******************************************************
//* C O M M A N D N O T E X E C U T E D *
//*******************************************************
//* ELIMINATE FAULT AND ENTER NOT EXECUTED COMMANDS *
//*******************************************************
<ENDFILE;

P30305-X1118-G503-01-7618 12-29
12.5.6. Command File CF.11.DIAGMB1G503
<CMDFILE;
/* CF.11.DIAGMB1G503 */
/*
/***************************************************/
/* CF-NAME : CF.11.DIAGMB1G503 */
/* */
/* PURPOSE : DIAGNOSIS OF MB-1 */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* REMARKS : FOR MB CAPACITY STAGE UP TO DE54 */
/***************************************************/
/*
//***************************************************
//* COMMAND FILE CF.11.DIAGMB1G503 STARTED *
//***************************************************
/*
<SET CFOPT: ACKCFS=ALL, DANCMD=EXEC, ACKREQ=POS, OFF=16;
/*
//***************************************************
//* DIAGNOSIS OF MB-1 *
//***************************************************
/*
<DISP EXDDAT;
<STAT SSP;
<STAT MB;
<STAT SN;
/*
<CONF MB: MB=1,OST=MBL;
<SKIP CMD: ON=32, LABEL=ERR;
<DIAG MB: MB=1,TA=ALL;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<CONF IOP:IOP=IOPMB-33,OST=MBL;
<SKIP CMD: ON=32, LABEL=ERR;
/*
//***************************************************
//* IOPMB-35 ONLY IN STAGE DE52,DE54 *
//***************************************************
/*
<CONF IOP:IOP=IOPMB-35,OST=MBL;
/*
//***************************************************
//* IOPMB-37,39 ONLY IN STAGE DE54 *
//***************************************************
/*
<CONF IOP:IOP=IOPMB-37,OST=MBL;
<CONF IOP:IOP=IOPMB-39,OST=MBL;
/*
<DIAG MB: MB=1,TA=ALL;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<CONF MB: MB=1,OST=ACT;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<CONF IOP:IOP=IOPMB-33,OST=ACT;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<CONF IOP:IOP=IOPMB-35,OST=ACT;

12-30 P30305-X1118-G503-01-7618
<CONF IOP:IOP=IOPMB-37,OST=ACT;

P30305-X1118-G503-01-7618 12-31
<CONF IOP:IOP=IOPMB-39,OST=ACT;
/*
<STAT SSP;
<STAT MB;
<STAT SN;
/*
<RESET CFOPT;
//******************************************************
//* PLEASE CHECK FOR FAULTS AND IF MB-0,1, SN-0,1 *
//* AND IOPMBS ARE IN ACT *
//******************************************************
<ENDFILE;
/*
.ERR<STEP;
<SET CFOPT: ON=16, SCOPE=GLOBAL;
//*******************************************************
//* C O M M A N D N O T E X E C U T E D *
//*******************************************************
//* ELIMINATE FAULT AND ENTER NOT EXECUTED COMMANDS *
//*******************************************************
<ENDFILE;

12-32 P30305-X1118-G503-01-7618
12.5.7. Command File CF.11.MBSNPLAG503
<CMDFILE;
/* CF.11.MBSNPLAG503 */
/*
/***************************************************/
/* CF-NAME : CF.11.MBSNPLAG503 */
/* */
/* PURPOSE : CONFIGURATION OF MB AND SN TO */
/* STATUS PLA IN V11 */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* REMARKS : FOR MB AND SN WITH CAPACITY */
/* STAGE UP TO DE54 */
/***************************************************/
/*
//***************************************************
//* COMMAND FILE CF.11.MBSNPLAG503 STARTED *
//***************************************************
//* CONFIGURATION OF MB AND SN TO PLA V11 *
//* CAPACITY STAGE IS UP TO SN:504LTG *
//***************************************************
/*
<SET CFOPT: ACKCFS=ALL,DANCMD=EXEC,ACKREQ=POS;
/*
<DISP EXDDAT;
/*
//***************************************************
//* CONFIGURATION OF SN TO MBL *
//***************************************************
//***************************************************
//* IGNORE ERROR MESSAGE FOR UNITS NOT AVAILABLE *
//***************************************************
/*
<CONF TSG: SN=0, TSG=0, OST=MBL;
<CONF TSG: SN=0, TSG=1, OST=MBL;
<CONF TSG: SN=0, TSG=2, OST=MBL;
<CONF TSG: SN=0, TSG=3, OST=MBL;
<CONF TSG: SN=0, TSG=4, OST=MBL;
<CONF TSG: SN=0, TSG=5, OST=MBL;
<CONF TSG: SN=0, TSG=6, OST=MBL;
<CONF TSG: SN=0, TSG=7, OST=MBL;
/*
<CONF SSG: SN=0, SSG=0, OST=MBL;
<CONF SSG: SN=0, SSG=1, OST=MBL;
<CONF SSG: SN=0, SSG=2, OST=MBL;
<CONF SSG: SN=0, SSG=3, OST=MBL;
/*

P30305-X1118-G503-01-7618 12-33
//***************************************************
//* CONFIGURATION OF MB TO MBL *
//***************************************************
//***************************************************
//* IGNORE ERROR MESSAGE FOR UNITS NOT AVAILABLE *
//***************************************************
/*
<CONF MBUL: MB=0, MBUL=0, OST=MBL;
<CONF MBUL: MB=0, MBUL=1, OST=MBL;
<CONF MBUL: MB=0, MBUL=2, OST=MBL;
<CONF MBUL: MB=0, MBUL=3, OST=MBL;
<CONF MBUL: MB=0, MBUL=4, OST=MBL;
<CONF MBUL: MB=0, MBUL=5, OST=MBL;
<CONF MBUL: MB=0, MBUL=6, OST=MBL;
<CONF MBUL: MB=0, MBUL=7, OST=MBL;
/*
<CONF MBUS: MB=0, MBUS=0, OST=MBL;
<CONF MBUS: MB=0, MBUS=1, OST=MBL;
<CONF MBUS: MB=0, MBUS=2, OST=MBL;
<CONF MBUS: MB=0, MBUS=3, OST=MBL;
/*
//***************************************************
//* CONFIGURATION OF SN TO PLA *
//***************************************************
//***************************************************
//* IGNORE ERROR MESSAGE FOR UNITS NOT AVAILABLE *
//***************************************************
/*
<CONF TSG: SN=0, TSG=0, OST=PLA;
<CONF TSG: SN=0, TSG=1, OST=PLA;
<CONF TSG: SN=0, TSG=2, OST=PLA;
<CONF TSG: SN=0, TSG=3, OST=PLA;
<CONF TSG: SN=0, TSG=4, OST=PLA;
<CONF TSG: SN=0, TSG=5, OST=PLA;
<CONF TSG: SN=0, TSG=6, OST=PLA;
<CONF TSG: SN=0, TSG=7, OST=PLA;
/*
<CONF SSG: SN=0, SSG=0, OST=PLA;
<CONF SSG: SN=0, SSG=1, OST=PLA;
<CONF SSG: SN=0, SSG=2, OST=PLA;
<CONF SSG: SN=0, SSG=3, OST=PLA;
/*

12-34 P30305-X1118-G503-01-7618
//***************************************************
//* CONFIGURATION OF MB TO PLA *
//***************************************************
//***************************************************
//* IGNORE ERROR MESSAGE FOR UNITS NOT AVAILABLE *
//***************************************************
/*
<CONF MBUL: MB=0, MBUL=0, OST=PLA;
<CONF MBUL: MB=0, MBUL=1, OST=PLA;
<CONF MBUL: MB=0, MBUL=2, OST=PLA;
<CONF MBUL: MB=0, MBUL=3, OST=PLA;
<CONF MBUL: MB=0, MBUL=4, OST=PLA;
<CONF MBUL: MB=0, MBUL=5, OST=PLA;
<CONF MBUL: MB=0, MBUL=6, OST=PLA;
<CONF MBUL: MB=0, MBUL=7, OST=PLA;
/*
<CONF MBUS: MB=0, MBUS=0, OST=PLA;
<CONF MBUS: MB=0, MBUS=1, OST=PLA;
<CONF MBUS: MB=0, MBUS=2, OST=PLA;
<CONF MBUS: MB=0, MBUS=3, OST=PLA;
/*
<STAT MB;
<STAT SN;
/*
//***************************************************
//* CHECK MB AND SN STATUS *
//* ALL MB/SN UNITS MUST BE PLA *
//***************************************************
/*
<RESET CFOPT;
<ENDFILE;

P30305-X1118-G503-01-7618 12-35
12.5.8. Command File CF.11.DIUSTATG503
<CMDFILE;
/* CF.11.DIUSTATG503 */
/*
/***************************************************/
/* CF-NAME : CF.11.DIUSTATG503 */
/* */
/* PURPOSE : INQUIRY DIU AND CR STATUS */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* REMARKS : */
/***************************************************/
/*
//***************************************************
//* COMMAND FILE CF.11.DIUSTATG503 STARTE *
//***************************************************
//* INQUIRY OF DIU AND CR STATUS *
//***************************************************
/*
<SET CFOPT: ACKCFS=ALL,DANCMD=EXEC,ACKREQ=POS, OFF=16;
/*
//********************************************/
//* INQUIRY OF DIU IN ACT */
//********************************************/
<STAT DIU: LTG=X-X, OST=ACT;
/*
/*
//********************************************/
//* INQUIRY OF DIU IN CBL */
//********************************************/
<STAT DIU: LTG=X-X, OST=CBL;
/*
/*
//********************************************/
//* INQUIRY OF DIU IN MBL */
//********************************************/
<STAT DIU: LTG=X-X, OST=MBL;
/*
/*
//********************************************/
//* INQUIRY OF DIU IN PLA */
//********************************************/
<STAT DIU: LTG=X-X, OST=PLA;
/*
/*
//********************************************/
//* INQUIRY OF CR IN ACT */
//********************************************/
<STAT CR: LTG=X-X, OST=ACT;
/*
/*
//********************************************/
//* INQUIRY OF CR IN MBL */
//********************************************/
<STAT CR: LTG=X-X, OST=MBL;
/*
/*
//********************************************/
//* INQUIRY OF CR IN PLA */

12-36 P30305-X1118-G503-01-7618
//********************************************/

P30305-X1118-G503-01-7618 12-37
<STAT CR: LTG=X-X, OST=PLA;
/*
<RESET CFOPT;
<ENDFILE;

12-38 P30305-X1118-G503-01-7618
12.5.9. Command File CF.11.PLACSCG503
<CMDFILE;
/* CF.11.PLACSCG503 */
/*
/***************************************************/
/* CF-NAME : CF.11.PLACSCG503 */
/* */
/* LONG-NAME : CONFIGURATION OF CSC-LINKS */
/* TO PLA */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* PURPOSE : CONFIGURATION OF CSC-LINKS */
/* TO PLA: */
/* CSC-0 UP TO CSC-3 */
/***************************************************/
/*
<SET CFOPT: ACKCFS=ALL,DANCMD=EXEC,ACKREQ=POS;
/*
//***************************************************
//* COMMANDFILE CF.11.PLACSCG503 STARTED *
//***************************************************
//***************************************************
//* CONFIGURATION OF CSC-LINKS TO PLA: *
//* CSC-0 UP TO 3 *
//***************************************************
//***************************************************
//* IGNORE ERROR MESSAGE FOR NOT AVAILABLE *
//* CSC-LINKS *
//***************************************************
/*
<STAT SSP;
/*
<CONF CSC:CSC=0,OST=MBL;
<CONF CSC:CSC=0,OST=PLA;
<CONF CSC:CSC=1,OST=MBL;
<CONF CSC:CSC=1,OST=PLA;
<CONF CSC:CSC=2,OST=MBL;
<CONF CSC:CSC=2,OST=PLA;
<CONF CSC:CSC=3,OST=MBL;
<CONF CSC:CSC=3,OST=PLA;
/*
<STAT SSP;
/*
//***************************************************
//* COMMANDFILE FINISHED *
//***************************************************
//***************************************************
//* CHECK STATUS OF CSC-LINKS: *
//* ALL AVAILABLE CSC-LINKS IN PLA *
//***************************************************
//***************************************************
//* IF NECESSARY CONFIGURE CSC-LINKS MANUALLY *
//***************************************************
/*
<RESET CFOPT;
<ENDFILE;

P30305-X1118-G503-01-7618 12-39
12.5.10. Command File CF.11.PLAX25G503
<CMDFILE;
/* CF.11.PLAX25G503 */
/*
/***************************************************/
/* CF-NAME : CF.11.PLAX25G503 */
/* */
/* PURPOSE : CONFIGURATION OF X25-LINKS */
/* TO PLA */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* REMARKS : X25-LINK 0...7 */
/***************************************************/
/*
//***************************************************
//* COMMAND FILE CF.11.PLAX25G503 STARTED *
//***************************************************
//* CONFIGURATION OF X25-LINK 0..7 TO PLA *
//***************************************************
//***************************************************
//* IGNORE ERROR MESSAGES IF X25-LINK *
//* IS NOT AVAILABLE *
//***************************************************
/*
<SET CFOPT: ACKCFS=ALL,DANCMD=EXEC,ACKREQ=POS;
/*
<CONF X25LINK:X25LINK=0,OST=MBL;
<CONF X25LINK:X25LINK=0,OST=PLA;
<CONF X25LINK:X25LINK=1,OST=MBL;
<CONF X25LINK:X25LINK=1,OST=PLA;
<CONF X25LINK:X25LINK=2,OST=MBL;
<CONF X25LINK:X25LINK=2,OST=PLA;
<CONF X25LINK:X25LINK=3,OST=MBL;
<CONF X25LINK:X25LINK=3,OST=PLA;
<CONF X25LINK:X25LINK=4,OST=MBL;
<CONF X25LINK:X25LINK=4,OST=PLA;
<CONF X25LINK:X25LINK=5,OST=MBL;
<CONF X25LINK:X25LINK=5,OST=PLA;
<CONF X25LINK:X25LINK=6,OST=MBL;
<CONF X25LINK:X25LINK=6,OST=PLA;
<CONF X25LINK:X25LINK=7,OST=MBL;
<CONF X25LINK:X25LINK=7,OST=PLA;
/*
<STAT SSP;
/*
//***************************************************
//* CHECK STATUS OF X25-LINKS *
//* X25-LINK 0...7 MUST BE IN PLA *
//***************************************************
/*
<RESET CFOPT;
<ENDFILE;

12-40 P30305-X1118-G503-01-7618
12.5.11. Command File CF.11.REGMEMOG503
<CMDFILE;
/* CF.11.REGMEMOG503 */
/*
/***************************************************/
/* CF-NAME : CF.11.REGMEMOG503 */
/* */
/* PURPOSE : CREATING AND SAVING THE CA */
/* FILES FOR REGENERATION */
/* ON MO IN MOD-0 */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* REMARKS : A MO IS TO BE HELD READY. */
/* BEFORE STARTING THE COMMANDFILE */
/* THE MOD-0 IS TO BE LOADED */
/***************************************************/
/*
<SET CFOPT: ACKCFS=ERROR,DANCMD=EXEC,ACKREQ=POS,OFF=2;
/*
//***************************************************
//* COMMAND FILE CF.11.REGMEMOG503 STARTED *
//***************************************************
//* CREATING AND SAVING REGENERATION FILES *
//***************************************************
/*
//***************************************************
//* CHECKING IF CA.SU.APS.99 OR CA.TF.APS.99 *
//* IS ALREADY EXISTING *
//***************************************************
/*
<DISP FILE: FILE=CA.SU.APS.99;
<SKIPCMD: LABEL=MS, ON=32;
<SET CFOPT: ON=2;
/*
.MS <STEP;
<DISP FILE: FILE=CA.TF.APS.99;
<SKIPCMD: LABEL=CHECK, ON=32;
<SET CFOPT: ON=2;
/*
.CHECK <STEP;
<SKIPCMD: LABEL=ERROR, ON=2;
/*
/*
<DACT FNS: FNS=CA;
<INIT MO: MOD=0, CD=ISO, VSN=REGFIL;
<SKIPCMD: LABEL=ERR1, ON=32;
/*
<DISP FILE: FILE=CA.SU.UCHA;
<SKIPCMD: LABEL=AV2, OFF=32;
/*
//********************************************
//* FILE CA.SU.UCHA NOT EXISTING *
//* NO REGENERATION OF SUBSCRIBER-METERS *
//********************************************
<SKIPCMD: LABEL=S130;
/*
/*
.AV2 <STEP;

P30305-X1118-G503-01-7618 12-41
//********************************************
//* CREATION OF REGENERATIONFILE FOR *
//* SUBSCRIBER-METERS *
//********************************************
/*
<SAVE MET: TYPE=METSUB;
<SKIPCMD: LABEL=ERR3, ON=32;
<EDIT MET: FILE=CA.SU.APS.99, TYPE=METSUB, FUNC=APSCHANG;
<SKIPCMD: LABEL=ERR6, ON=32;
<TRANS FILE: FILE=CA.SU.APS.99, VSNR=REGFIL;
<SKIPCMD: LABEL=ERR5, ON=32;
/*
/*
.S130 <STEP;
<DISP FILE: FILE=CA.TF.UCHA;
<SKIPCMD: LABEL=AV3, OFF=32;
//********************************************
//* FILE CA.TF.UCHA NOT EXISTING *
//* NO REGENERATION OF S130-METERS *
//********************************************
<SKIPCMD: LABEL=OKAY;
/*
/*
.AV3 <STEP;
//********************************************
//* CREATION OF REGENERATIONFILE FOR *
//* S130-METERS *
//********************************************
/*
<SAVE MET: TYPE=METTFS;
<SKIPCMD: LABEL=ERR3, ON=32;
<EDIT MET: TYPE=METTFS, FILE=CA.TF.APS.99, FUNC=APSCHANG;
<SKIPCMD: LABEL=ERR8, ON=32;
<TRANS FILE: FILE=CA.TF.APS.99, VSNR=REGFIL;
<SKIPCMD: LABEL=ERR5, ON=32;
/*
<SKIPCMD: LABEL=OKAY;
/*
/*
.ERR1 <STEP;
// *************
// * FAULT 01 *
//********************************************
//* MO INITIALIZATION ERROR *
//********************************************
/*
<SKIPCMD: LABEL=END;
/*
/*
.ERR3 <STEP;
// *************
// * FAULT 03 *
//********************************************
//* METER SAVING FAULT *
//********************************************
/*
<SKIPCMD: LABEL=END;
/*
/*
.ERR5 <STEP;
// *************
// * FAULT 05 *
//********************************************
//* FAULT DURING FILETRANSFER *
//* ELIMINATE FAULT AND START PROCEDURE AGAIN*
//********************************************

12-42 P30305-X1118-G503-01-7618
/*

P30305-X1118-G503-01-7618 12-43
<SET CFOPT: ACKCFS=ALL;
<DISP MO: MOD=0;
<DISP FILE: VSN=REGFIL;
<SKIP CMD: LABEL=END;
/*
/*
.ERR6 <STEP;
// *************
// * FAULT 06 *
//********************************************
//* FAULT DURING CREATION OF SUBSCRIBERFILE *
//********************************************
<SKIPCMD: LABEL=END;
/*
/*
.ERR8 <STEP;
// *************
// * FAULT 08 *
//********************************************
//* FAULT DURING CREATION OF S130-FILE *
//********************************************
/*
<SKIPCMD: LABEL=END;
/*
/*
.OKAY <SET CFOPT: ACKCFS=ALL;
<DISP FILE: VSN=REGFIL;
//
//********************************************
//* ALL EXISTING CHARGE-FILES ON MO *
//* AVAILABLE ? *
//********************************************
/*
/*
<ACT FNS;
.END <ACT FNS: FNS=CA;
<RESET CFOPT;
<ENDFILE;
/*
/*
.ERROR <STEP;
/*
<RESET CFOPT;
//********************************************
//* FILE CA.SU.APS.99 AND/OR CA.TF.APS.99 *
//* ALREADY EXISTING *
//* CANCEL THE EXISTING FILES AND START *
//* COMMAND FILE CF.11.REGMEMOG503 AGAIN *
//********************************************
//* ERROR *
//********************************************
<ENDFILE;

12-44 P30305-X1118-G503-01-7618
12.5.12. Command File CF.11.PROG503
<CMDFILE;
/* CF.11.PROG503 */
/*
/***************************************************/
/* CF-NAME : CF.11.PROG503 */
/* */
/* PURPOSE : START OF PROCESSES IN */
/* INSTALLATION RECOVERY V11 */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* REMARKS : */
/***************************************************/
/*
//***************************************************
//* COMMAND FILE CF.11.PROG503 STARTED *
//***************************************************
//* STARTING PROCESSES IN INSTALLATION RECOVERY V11 *
//***************************************************
/*
<SET CFOPT: ACKCFS=ERROR,DANCMD=EXEC,ACKREQ=POS;
/*
<START OM: APPL=Q3IF;
/*
<START DB;
/*
<START PROCESS: NAME=ICSRV;
/*
<START PROCESS: NAME=CLTLM;
/*
<START PROCESS: NAME=QACEN;
/*
<START PROCESS: NAME=GAILS;
/*
<START PROCESS: NAME=JIAUP;
/*
<START PROCESS: NAME=ASCEX;
/*
<RESET CFOPT;
<ENDFILE;

P30305-X1118-G503-01-7618 12-45
12.5.13. Command File CF.11.SYSTATG503
<CMDFILE;
/* CF.11.SYSTATG503 */
/*
/***************************************************/
/* CF-NAME : CF.11.SYSTATG503 */
/* */
/* PURPOSE : INQUIRY OF SYSTEM STATUS */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* REMARKS : */
/***************************************************/
/*
//***************************************************
//* COMMAND FILE CF.11.SYSTATG503 STARTED *
//***************************************************
//* INQUIRY OF SYSTEM STATUS *
//***************************************************
/*
<SET CFOPT: ACKCFS=ALL,DANCMD=EXEC,ACKREQ=POS;
/*
//********************************************
//* INQUIRY OF UPDATE STATUS *
//********************************************
<DISP SPLITOPT;
<DISP UPDATE;
<STAT LOG;
/*
//********************************************
//* INQUIRY OF DISK CONTENTS *
//********************************************
<DISP FILE;
<DISP MD;
<DISP GEN;
/*
/*
//********************************************
//* INQUIRY OF SYSTEM REDUNDANCY *
//********************************************
<STAT SSP;
<STAT MB;
<STAT SN;
<DISP TSG: SN=X;
<STAT CCG;
<DISP CCG;
<STAT SYP;
<DISP LTG: LTG=X-X;
<STAT LTG: LTG=X-X;
<DISP DLU: DLU=X;
<STAT DLU: DLU=X;
<STAT DIU: LTG=X-X, OST=UNA;
<STAT CR: LTG=X-X, OST=UNA;
/*
/*
//********************************************
//* INQUIRY OF CCNC STATUS *
//********************************************
<STAT CCNC: UNIT=CCNP-X;
<STAT CCNC: UNIT=SIPA-X;

12-46 P30305-X1118-G503-01-7618
<STAT CCNC: UNIT=SILTC-X;

P30305-X1118-G503-01-7618 12-47
<STAT CCNC: UNIT=MUXM-X;
<STAT CCNC: UNIT=SILT-X;
/*
<DISP C7LINK: LSNAM=X;
<DISP C7LSET: LSNAM=X;
<DISP C7DP: DPC=X, NETIND=NAT0;
<DISP NUC;
/*
//********************************************
//* INQUIRY OF EXCHANGE DATA *
//********************************************
<DISP EXDDAT;
<STAT V5LINK: V5IFID=X, OST=ACT;
<DISP OUTSUP;
<DISP IAFEAT;
<DISP IAOPT;
<DISP METSAV;
<DISP SSPRT;
/*
//**********************************************
//* CHECK INTERROGATION RESULTS *
//**********************************************
//* IF NECESSARY CREATE REQUIRED CONFIGURATION *
//**********************************************
/*
<RESET CFOPT;
<ENDFILE;

12-48 P30305-X1118-G503-01-7618
12.5.14. Command File CF.11.UPDFILEG503
<CMDFILE;
/* CF.11.UPDFILEG503 */
/*
/***************************************************/
/* CF-NAME : CF.11.UPDFILEG503 */
/* */
/* PURPOSE : UPDATE OF CHARGE FILES ON DISK */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* REMARKS : */
/***************************************************/
/*
//***************************************************
//* COMMAND FILE CF.11.UPDFILEG503 STARTED *
//***************************************************
//* UPDATING CHARGE FILES ON DISK *
//***************************************************
/*
<SET CFOPT: ACKCFS=ALL,DANCMD=EXEC,ACKREQ=POS;
/*
//***************************************************
//* UPDATING CA METER FILES ON DISK *
//***************************************************
//* IGNORE ERROR MESSAGE IF METER TYPE IS *
//* NOT AVAILABLE *
//***************************************************
/*
<DISP EXDDAT;
/*
<SAVE MET:TYPE=METSUB;
<SAVE MET:TYPE=METSTAT;
<SAVE MET:TYPE=METTR;
<SAVE MET:TYPE=METTFS;
/*
//***************************************************
//* UPDATING IA AND IACHASTA FILES ON DISK *
//***************************************************
//* IGNORE ERROR MESSAGE IF IA FEATURE IS *
//* NOT AVAILABLE *
//***************************************************
/*
<DISP IAFEAT;
/*
<TRANS BUFFER:TYPE=AMA;
<TRANS BUFFER:TYPE=FIR;
<TRANS BUFFER:TYPE=IARA;
<TRANS BUFFER:TYPE=INA;
<TRANS BUFFER:TYPE=MAL;
<TRANS BUFFER:TYPE=MOB;
<TRANS BUFFER:TYPE=TOB;
<TRANS BUFFER:TYPE=TST;
<TRANS BUFFER:TYPE=UAM;
<TRANS BUFFER:TYPE=DNOB;
<TRANS BUFFER:TYPE=PMOB;
<TRANS BUFFER:TYPE=ERS;
<TRANS BUFFER:TYPE=MCR;
/*
<DISP IACRG;

P30305-X1118-G503-01-7618 12-49
/*

12-50 P30305-X1118-G503-01-7618
<EDIT MET:TYPE=IACMET;
/*
//***************************************************
//* CHECK IF ALL PROJECT-SPECIFIC FILES *
//* ARE UPDATED ON DISK *
//***************************************************
/*
<RESET CFOPT;
<ENDFILE;

P30305-X1118-G503-01-7618 12-51
12.5.15. Command File CF.11.V5CHECKG503
<CMDFILE;
/* CF.11.V5CHECKG503 */
/*
/***************************************************/
/* CF-NAME : CF.11.V5CHECKG503 */
/* */
/* PURPOSE : CHECK OF V5-LINK DISTRIBUTION */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* REMARKS : */
/***************************************************/
/*
//***************************************************
//* COMMAND FILE CF.11.V5CHECKG503 STARTED *
//***************************************************
//* CHECKING V5-LINK DISTRIBUTION *
//***************************************************
/*
<SET CFOPT: ACKCFS=ALL,DANCMD=EXEC,ACKREQ=POS;
/*
<DISP DLUMOD: DLU=X;
<DISP V5LINK: V5IFID=X;
/*
<RESET CFOPT;
<ENDFILE;

12-52 P30305-X1118-G503-01-7618
12.6. Command Files V17/CCNC

12.6.1. Command File CF.17.ACTCAPG503


<CMDFILE;
/* CF.17.ACTCAPG503 */
/*
/***************************************************/
/* CF-NAME : CF.17.ACTCAPG503 */
/* */
/* PURPOSE : ACTIVATION OF CAPS */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* REMARKS : CAP-0 UP TO CAP-5 */
/***************************************************/
/*
//***************************************************
//* COMMAND FILE CF.17.ACTCAPG503 STARTED *
//***************************************************
//* ACTIVATION OF CAP-0 UP TO CAP-5 *
//***************************************************
/*
<SET CFOPT: ACKCFS=ALL, DANCMD=EXEC, ACKREQ=POS;
/*
//***************************************************
//* CONFIGURING THE CAPS *
//***************************************************
/****************************************************
/* IGNORE ERROR MESSAGE, IF NO BUS INTERFACE FOR *
/* CAP-X AVAILABLE *
/* *
/* IGNORE ERROR MESSAGE, IF CONFIGURATION TO PLA *
/* OF CAP-X IS NOT POSSIBLE *
/****************************************************
/*
<CONF CAP: CAP=0, OST=MBL;
<SKIP CMD: ON=32, LABEL=STA;
<CONF CAP: CAP=0, OST=ACT;
<CONF CAP: CAP=0, OST=PLA;
/*
<CONF CAP: CAP=1, OST=MBL;
<SKIP CMD: ON=32, LABEL=STA;
<CONF CAP: CAP=1, OST=ACT;
<CONF CAP: CAP=1, OST=PLA;
/*
<CONF CAP: CAP=2, OST=MBL;
<SKIP CMD: ON=32, LABEL=STA;
<CONF CAP: CAP=2, OST=ACT;
<CONF CAP: CAP=2, OST=PLA;
/*
<CONF CAP: CAP=3, OST=MBL;
<SKIP CMD: ON=32, LABEL=STA;
<CONF CAP: CAP=3, OST=ACT;
<CONF CAP: CAP=3, OST=PLA;
/*
<CONF CAP: CAP=4, OST=MBL;
<SKIP CMD: ON=32, LABEL=STA;
<CONF CAP: CAP=4, OST=ACT;
<CONF CAP: CAP=4, OST=PLA;

P30305-X1118-G503-01-7618 12-53
/*
<CONF CAP: CAP=5, OST=MBL;
<SKIP CMD: ON=32, LABEL=STA;
<CONF CAP: CAP=5, OST=ACT;
<CONF CAP: CAP=5, OST=PLA;
/*
.STA<STEP;
/*
<STAT SSP;
/*
<RESET CFOPT;
//**************************************************************
//* PLEASE CHECK THE CAP STATES AND CONFIGURE, IF NECESSARY: *
//* ALL AVAILABLE CAPS MUST BE IN ACT *
//* NOT EXISTING BUT CREATED CAPS MUST BE IN PLA *
//**************************************************************
/*
<ENDFILE;

12-54 P30305-X1118-G503-01-7618
12.6.2. Command File CF.17.ACTCSCG503
<CMDFILE;
/* CF.17.ACTCSCG503 */
/*
/***************************************************/
/* CF-NAME : CF.17.ACTCSCG503 */
/* */
/* PURPOSE : ACTIVATION OF CSC-LINKS */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* REMARKS : CSC-LINK 0..3 */
/***************************************************/
/*
//***************************************************
//* COMMAND FILE CF.17.ACTCSCG503 STARTED *
//***************************************************
//* ACTIVATION OF CSC-LINK 0..3 *
//***************************************************
//* IGNORE ERROR MESSAGES IF CSC-LINK *
//* IS NOT AVAILABLE *
//***************************************************
/*
<SET CFOPT: ACKCFS=ALL,DANCMD=EXEC,ACKREQ=POS;
/*
<ENTR ALMODE: HLIM=YES;
/*
<STAT SSP;
/*
<CONF CSC:CSC=0,OST=MBL;
<CONF CSC:CSC=1,OST=MBL;
<CONF CSC:CSC=2,OST=MBL;
<CONF CSC:CSC=3,OST=MBL;
<CONF CSC:CSC=0,OST=ACT;
<CONF CSC:CSC=1,OST=ACT;
<CONF CSC:CSC=2,OST=ACT;
<CONF CSC:CSC=3,OST=ACT;
/*
<STAT SSP;
//***************************************************
//* AVAILABLE CSC-LINKS MUST BE IN ACT *
//* IF NOT ACTIVATE CSC-LINKS *
//***************************************************
/*
<RESET CFOPT;
<ENDFILE;

P30305-X1118-G503-01-7618 12-55
12.6.3. Command File CF.17.ACTX25G503
<CMDFILE;
/* CF.17.ACTX25G503 */
/*
/***************************************************/
/* CF-NAME : CF.17.ACTX25G503 */
/* */
/* PURPOSE : ACTIVATION OF X25-LINKS */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* REMARKS : X25-LINK 0...7 */
/***************************************************/
/*
//***************************************************
//* COMMAND FILE CF.17.ACTX25G503 STARTED *
//***************************************************
//* ACTIVATION OF X25-LINK 0...7 *
//***************************************************
//* IGNORE ERROR MESSAGES IF X25LINK *
//* IS NOT AVAILABLE *
//***************************************************
/*
<SET CFOPT: ACKCFS=ALL,DANCMD=EXEC,ACKREQ=POS;
/*
<ENTR ALMODE: HLIM=YES;
/*
<STAT SSP;
/*
<CONF X25LINK:X25LINK=0,OST=MBL;
<CONF X25LINK:X25LINK=0,OST=ACT;
<CONF X25LINK:X25LINK=1,OST=MBL;
<CONF X25LINK:X25LINK=1,OST=ACT;
<CONF X25LINK:X25LINK=2,OST=MBL;
<CONF X25LINK:X25LINK=2,OST=ACT;
<CONF X25LINK:X25LINK=3,OST=MBL;
<CONF X25LINK:X25LINK=3,OST=ACT;
<CONF X25LINK:X25LINK=4,OST=MBL;
<CONF X25LINK:X25LINK=4,OST=ACT;
<CONF X25LINK:X25LINK=5,OST=MBL;
<CONF X25LINK:X25LINK=5,OST=ACT;
<CONF X25LINK:X25LINK=6,OST=MBL;
<CONF X25LINK:X25LINK=6,OST=ACT;
<CONF X25LINK:X25LINK=7,OST=MBL;
<CONF X25LINK:X25LINK=7,OST=ACT;
/*
<STAT SSP;
//***************************************************
//* AVAILABLE X25-LINKS MUST BE IN ACT *
//* IF NOT ACTIVATE X25-LINKS *
//***************************************************
/*
<RESET CFOPT;
<ENDFILE;

12-56 P30305-X1118-G503-01-7618
12.6.4. Command File CF.17.ACTIOPG503

<CMDFILE;
/* CF.17.ACTIOPG503 */
/*
/***************************************************/
/* CF-NAME : CF.17.ACTIOPG503 */
/* */
/* PURPOSE : ACTIVATION OF IOPMBS */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* REMARKS : IOPMB-0,1,32 up to 43 */
/***************************************************/
/*
//***************************************************
//* COMMAND FILE CF.17.ACTIOPG503 STARTED *
//***************************************************
//* ACTIVATION OF IOPMBS *
//***************************************************
/*
<SET CFOPT: ACKCFS=ALL,DANCMD=EXEC,ACKREQ=POS;
/*
<DISP EXDDAT;
/*

<CONF IOP: IOP=IOPMB-0, OST=MBL;


<CONF IOP: IOP=IOPMB-0, OST=ACT;
<CONF IOP: IOP=IOPMB-1, OST=MBL;
<CONF IOP: IOP=IOPMB-1, OST=ACT;
<CONF IOP: IOP=IOPMB-32, OST=MBL;
<CONF IOP: IOP=IOPMB-32, OST=ACT;
<CONF IOP: IOP=IOPMB-33, OST=MBL;
<CONF IOP: IOP=IOPMB-33, OST=ACT;
<CONF IOP: IOP=IOPMB-40, OST=MBL;
<CONF IOP: IOP=IOPMB-40, OST=ACT;
<CONF IOP: IOP=IOPMB-41, OST=MBL;
<CONF IOP: IOP=IOPMB-41, OST=ACT;
<CONF IOP: IOP=IOPMB-42, OST=MBL;
<CONF IOP: IOP=IOPMB-42, OST=ACT;
<CONF IOP: IOP=IOPMB-43, OST=MBL;
<CONF IOP: IOP=IOPMB-43, OST=ACT;
<CONF IOP: IOP=IOPMB-34, OST=MBL;
<SKIP CMD: LABEL=MES1, ON=32;
<CONF IOP: IOP=IOPMB-34, OST=ACT;
<CONF IOP: IOP=IOPMB-35, OST=MBL;
<CONF IOP: IOP=IOPMB-35, OST=ACT;
<CONF IOP: IOP=IOPMB-36, OST=MBL;
<SKIP CMD: LABEL=MES2, ON=32;
<CONF IOP: IOP=IOPMB-36, OST=ACT;
<CONF IOP: IOP=IOPMB-37, OST=MBL;
<CONF IOP: IOP=IOPMB-37, OST=ACT;
<CONF IOP: IOP=IOPMB-38, OST=MBL;
<CONF IOP: IOP=IOPMB-38, OST=ACT;
<CONF IOP: IOP=IOPMB-39, OST=MBL;
<CONF IOP: IOP=IOPMB-39, OST=ACT;
<SKIP CMD: LABEL=STA;

P30305-X1118-G503-01-7618 12-57
.MES1<STEP;
//***************************************************
//* IGNORE ERROR MESSAGE *
//* DE-TYPE IS DE51 *
//***************************************************
<SKIP CMD: LABEL=STA;
.MES2<STEP;
//***************************************************
//* IGNORE ERROR MESSAGE *
//* DE-TYPE IS DE52 *
//***************************************************
.STA<STEP;
/*
<STAT SSP;
//***************************************************
//* IOPMB-0,1,32 UP TO 43 MUST BE IN ACT *
//* IF NOT ACTIVATE AVAILABLE IOPMBS *
//***************************************************
/*
<RESET CFOPT;
<ENDFILE;

12-58 P30305-X1118-G503-01-7618
12.6.5. Command File CF.17.DIAGCCNG503

<CMDFILE;
/* CF.17.DIAGCCNG503 */
/*
/***************************************************/
/* CF-NAME : CF.17.DIAGCCNG503 */
/* */
/* PURPOSE : DIAGNOSIS OF CCNC */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* REMARKS : INITIAL STATUS: CCNP-0 IN STB */
/* CCNP-1 IN ACT */
/***************************************************/
/*
//***************************************************
//* COMMAND FILE CF.17.DIAGCCNG503 STARTED *
//***************************************************
//* DIAGNOSIS OF CCNC *
//***************************************************
/*
<SET CFOPT: ACKCFS=ALL, DANCMD=EXEC, ACKREQ=POS, OFF=16;
/*
//***************************************************
//* DIAGNOSIS OF CCNP-0 *
//***************************************************
/*
<STAT SSP;
<STAT CCNC:UNIT=CCNP-X;
/*
<CONF CCNC:UNIT=CCNP-0,OST=MBL;
<SKIP CMD: ON=32, LABEL=ERR;
<DIAG CCNC:UNIT=CCNP-0;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<CONF IOP:IOP=IOPMB-0,OST=MBL;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<DIAG CCNC:UNIT=CCNP-0;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<CONF CCNC:UNIT=CCNP-0,OST=STB;
<SKIP CMD: ON=32, LABEL=ERR;
<CONF CCNC:UNIT=CCNP-0,OST=ACT;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<CONF IOP:IOP=IOPMB-0,OST=ACT;
<SKIP CMD: ON=32, LABEL=ERR;
/*

P30305-X1118-G503-01-7618 12-59
//**************************************************
//* DIAGNOSIS OF CCNP-1 *
//**************************************************
/*
<STAT SSP;
<STAT CCNC:UNIT=CCNP-X;
/*
<CONF CCNC:UNIT=CCNP-1,OST=MBL;
<SKIP CMD: ON=32, LABEL=ERR;
<DIAG CCNC:UNIT=CCNP-1;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<CONF IOP:IOP=IOPMB-1,OST=MBL;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<DIAG CCNC:UNIT=CCNP-1;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<CONF CCNC:UNIT=CCNP-1,OST=STB;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<CONF IOP:IOP=IOPMB-1,OST=ACT;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<STAT SSP;
<STAT CCNC:UNIT=CCNP-X;
/*
<RESET CFOPT;
//**************************************************************
//* PLEASE CHECK FOR FAILURES AND IF CCNPS ARE IN ACT/STB, *
//* IOPMB-0,1 IN ACT *
//**************************************************************
<ENDFILE;
/*
/*
.ERR<STEP;
<SET CFOPT: ON=16, SCOPE=GLOBAL;
//**************************************************************
//* C O M M A N D N O T E X E C U T E D *
//**************************************************************
//* ELIMINATE FAULT AND ENTER NOT EXECUTED COMMANDS *
//**************************************************************
<ENDFILE;

12-60 P30305-X1118-G503-01-7618
12.6.6. Command File CF.17.DIAGMB0G503
<CMDFILE;
/* CF.17.DIAGMB0G503 */
/*
/***************************************************/
/* CF-NAME : CF.17.DIAGMB0G503 */
/* */
/* PURPOSE : DIAGNOSIS OF MB-0 */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* REMARKS : FOR MB CAPACITY STAGE UP TO DE54 */
/***************************************************/
/*
//***************************************************
//* COMMAND FILE CF.17.DIAGMB0G503 STARTED *
//***************************************************
/*
<SET CFOPT: ACKCFS=ALL, DANCMD=EXEC, ACKREQ=POS, OFF=16;
/*
//***************************************************
//* DIAGNOSIS OF MB-0 *
//***************************************************
/*
<DISP EXDDAT;
<STAT SSP;
<STAT MB;
<STAT SN;
/*
<CONF MB: MB=0,OST=MBL;
<SKIP CMD: ON=32, LABEL=ERR;
<DIAG MB: MB=0;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<CONF IOP:IOP=IOPMB-32,OST=MBL;
<SKIP CMD: ON=32, LABEL=ERR;
/*
//***************************************************
//* AVAILABILITY OF IOPMB-34 *
//* DEPENDS ON EXCHANGE TYPE AND NO. OF LTG *
//***************************************************
/*
<CONF IOP:IOP=IOPMB-34,OST=MBL;
/*

P30305-X1118-G503-01-7618 12-61
//***************************************************
//* AVAILABILITY OF IOPMB-36 AND 38 *
//* DEPENDS ON EXCHANGE TYPE AND NO. OF LTG *
//***************************************************
/*
<CONF IOP:IOP=IOPMB-36,OST=MBL;
<CONF IOP:IOP=IOPMB-38,OST=MBL;
/*
<DIAG MB: MB=0;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<CONF MB: MB=0,OST=ACT;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<CONF IOP:IOP=IOPMB-32,OST=ACT;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<CONF IOP:IOP=IOPMB-34,OST=ACT;
<CONF IOP:IOP=IOPMB-36,OST=ACT;
<CONF IOP:IOP=IOPMB-38,OST=ACT;
/*
<STAT SSP;
<STAT MB;
<STAT SN;
/*
<RESET CFOPT;
//******************************************************
//* PLEASE CHECK FOR FAULTS AND IF MB-0,1, SN-0,1 *
//* AND IOPMBS ARE IN ACT *
//******************************************************
<ENDFILE;
/*
.ERR<STEP;
<SET CFOPT: ON=16, SCOPE=GLOBAL;
//*******************************************************
//* C O M M A N D N O T E X E C U T E D *
//*******************************************************
//* ELIMINATE FAULT AND ENTER NOT EXECUTED COMMANDS *
//*******************************************************
<ENDFILE;

12-62 P30305-X1118-G503-01-7618
12.6.7. Command File CF.17.DIAGMB1G503
<CMDFILE;
/* CF.17.DIAGMB1G503 */
/*
/***************************************************/
/* CF-NAME : CF.17.DIAGMB1G503 */
/* */
/* PURPOSE : DIAGNOSIS OF MB-1 */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* REMARKS : FOR MB CAPACITY STAGE UP TO DE54 */
/***************************************************/
/*
//***************************************************
//* COMMAND FILE CF.17.DIAGMB1G503 STARTED *
//***************************************************
/*
<SET CFOPT: ACKCFS=ALL, DANCMD=EXEC, ACKREQ=POS, OFF=16;
/*
//***************************************************
//* DIAGNOSIS OF MB-1 *
//***************************************************
/*
<DISP EXDDAT;
<STAT SSP;
<STAT MB;
<STAT SN;
/*
<CONF MB: MB=1,OST=MBL;
<SKIP CMD: ON=32, LABEL=ERR;
<DIAG MB: MB=1;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<CONF IOP:IOP=IOPMB-33,OST=MBL;
<SKIP CMD: ON=32, LABEL=ERR;
/*
//***************************************************
//* AVAILABILITY OF IOPMB-35 *
//* DEPENDS ON EXCHANGE TYPE AND NO. OF LTG *
//***************************************************
/*
<CONF IOP:IOP=IOPMB-35,OST=MBL;
/*

P30305-X1118-G503-01-7618 12-63
//***************************************************
//* AVAILABILITY OF IOPMB-37 AND 39 *
//* DEPENDS ON EXCHANGE TYPE AND NO. OF LTG *
//***************************************************
/*
<CONF IOP:IOP=IOPMB-37,OST=MBL;
<CONF IOP:IOP=IOPMB-39,OST=MBL;
/*
<DIAG MB: MB=1;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<CONF MB: MB=1,OST=ACT;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<CONF IOP:IOP=IOPMB-33,OST=ACT;
<SKIP CMD: ON=32, LABEL=ERR;
/*
<CONF IOP:IOP=IOPMB-35,OST=ACT;
<CONF IOP:IOP=IOPMB-37,OST=ACT;
<CONF IOP:IOP=IOPMB-39,OST=ACT;
/*
<STAT SSP;
<STAT MB;
<STAT SN;
/*
<RESET CFOPT;
//******************************************************
//* PLEASE CHECK FOR FAULTS AND IF MB-0,1, SN-0,1 *
//* AND IOPMBS ARE IN ACT *
//******************************************************
<ENDFILE;
/*
.ERR<STEP;
<SET CFOPT: ON=16, SCOPE=GLOBAL;
//*******************************************************
//* C O M M A N D N O T E X E C U T E D *
//*******************************************************
//* ELIMINATE FAULT AND ENTER NOT EXECUTED COMMANDS *
//*******************************************************
<ENDFILE;

12-64 P30305-X1118-G503-01-7618
12.6.8. Command File CF.17.DIUSTATG503
<CMDFILE;
/* CF.17.DIUSTATG503 */
/*
/***************************************************/
/* CF-NAME : CF.17.DIUSTATG503 */
/* */
/* PURPOSE : INQUIRY DIU AND CR STATUS */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* REMARKS : */
/***************************************************/
/*
//***************************************************
//* COMMAND FILE CF.17.DIUSTATG503 STARTED *
//***************************************************
//* INQUIRY OF DIU AND CR STATUS *
//***************************************************
/*
<SET CFOPT: ACKCFS=ALL,DANCMD=EXEC,ACKREQ=POS, OFF=16;
/*
//********************************************/
//* INQUIRY OF DIU IN ACT */
//********************************************/
<STAT DIU: LTG=X-X, OST=ACT;
/*
//********************************************/
//* INQUIRY OF DIU IN CBL */
//********************************************/
<STAT DIU: LTG=X-X, OST=CBL;
/*
//********************************************/
//* INQUIRY OF DIU IN MBL */
//********************************************/
<STAT DIU: LTG=X-X, OST=MBL;
/*
//********************************************/
//* INQUIRY OF DIU IN PLA */
//********************************************/
<STAT DIU: LTG=X-X, OST=PLA;
/*
//********************************************/
//* INQUIRY OF CR IN ACT */
//********************************************/
<STAT CR: LTG=X-X, OST=ACT;
/*
//********************************************/
//* INQUIRY OF CR IN MBL */
//********************************************/
<STAT CR: LTG=X-X, OST=MBL;
/*
//********************************************/
//* INQUIRY OF CR IN PLA */
//********************************************/
<STAT CR: LTG=X-X, OST=PLA;
/*
<RESET CFOPT;
<ENDFILE;

P30305-X1118-G503-01-7618 12-65
12.6.9. Command File CF.17.HEXLTGG503
<CMDFILE;
/* CF.17.HEXLTGG503 */
/*
/***************************************************/
/* CF-NAME : CF.17.HEXLTGG503 */
/* */
/* PURPOSE : INQUIRY OF SEMIPERMANENT STATUS */
/* TABLE OF LTG V17 */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* REMARKS : FOR SN STAGE DE4 UP TO DE54 */
/***************************************************/
/*
//***************************************************
//* COMMAND FILE CF.17.HEXLTGG503 STARTED *
//***************************************************
//* INQUIRY OF SEMIPERMANENT STATUS TABLE LTG V17 *
//***************************************************
/*
<SET CFOPT: ACKCFS=ALL,DANCMD=EXEC,ACKREQ=POS;
/*
//***************************************************
//* INQUIRY OF CREATED LTGS *
//***************************************************
<DISP LTG: LTG=X-X;
/*
/*
//***************************************************
//* INQUIRY OF STATUS TABLE LTG *
//***************************************************
<DMP CPIMDMP: PLF=BAPM, ADDR="APSCMY00.BBSCPA0C.LTGDAA3P
#+H'271B4"&&"+H'200";
/*
<RESET CFOPT;
<ENDFILE;

12-66 P30305-X1118-G503-01-7618
12.6.10. Command File CF.17.HEXMBBG503
<CMDFILE;
/* CF.17.HEXMBBG503 */
/*
/***************************************************/
/* CF-NAME : CF.17.HEXMBBG503 */
/* LONG-NAME : INQUIRY OF SEMIPERMANENT STATUS */
/* TABLE OF MBB IN V17 */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* PURPOSE : INQUIRY SEMIPERMANENT STATUS */
/* TABLE OF MBB IN V17 */
/***************************************************/
//***************************************************
//* COMMAND FILE CF.17.HEXMBBG503 STARTED *
//* *
//* INQUIRY OF SEMIPER. STATUS TABLE MB IN V17 *
//***************************************************
/*
<SET CFOPT: ACKCFS=ALL,DANCMD=EXEC,ACKREQ=POS, OFF=16;
/*
/*
//********************************************/
//* INQUIRY OF STATUS TABLE MBB */
//********************************************/
<DMP CPIMDMP: PLF=BAPM, ADDR="APSCMY00.BBSCPA0C.MEBDAA3P"
#&&"+H'180";
/*
/*
<RESET CFOPT;
<ENDFILE;

P30305-X1118-G503-01-7618 12-67
12.6.11. Command File CF.17.HEXSNBG503
<CMDFILE;
/* CF.17.HEXSNBG503 */
/*
/***************************************************/
/* CF-NAME : CF.17.HEXSNBG503 */
/* LONG-NAME : INQUIRY OF SEMIPERMANENT STATUS */
/* TABLE OF SN IN V17 */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* PURPOSE : INQUIRY SEMIPERMANENT STATUS */
/* TABLE OF SN IN V17 */
/***************************************************/
//***************************************************
//* COMMAND FILE CF.17.HEXSNBG503 STARTED *
//* *
//* INQUIRY OF SEMIPERMANENT STATUS TABLE SN V17 *

//***************************************************
/*
<SET CFOPT: ACKCFS=ALL,DANCMD=EXEC,ACKREQ=POS, OFF=16;
/*
//********************************************/
//* INQUIRY OF STATUS TABLE SNB */
//********************************************/
<DMP CPIMDMP: PLF=BAPM, ADDR="APSCMY00.BBSCPA0C.SINDAA3P
#+H'0804"&&"+H'180";
/*
<RESET CFOPT;
<ENDFILE;

12-68 P30305-X1118-G503-01-7618
12.6.12. Command File CF.17.PLACSCG503
<CMDFILE;
/* CF.17.PLACSCG503 */
/*
/***************************************************/
/* CF-NAME : CF.17.PLACSCG503 */
/* */
/* LONG-NAME : CONFIGURATION OF CSC-LINKS */
/* TO PLA */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* PURPOSE : CONFIGURATION OF CSC-LINKS */
/* TO PLA: */
/* CSC-0 UP TO CSC-3 */
/***************************************************/
/*
<SET CFOPT: ACKCFS=ALL,DANCMD=EXEC,ACKREQ=POS;
/*
//***************************************************
//* COMMANDFILE CF.17.PLACSCG503 STARTED *
//***************************************************
//***************************************************
//* CONFIGURATION OF CSC-LINKS TO PLA: *
//* CSC-0 UP TO 3 *
//***************************************************
//***************************************************
//* IGNORE ERROR MESSAGE FOR NOT AVAILABLE *
//* CSC-LINKS *
//***************************************************
/*
<STAT SSP;
/*
<CONF CSC:CSC=0,OST=MBL;
<CONF CSC:CSC=0,OST=PLA;
<CONF CSC:CSC=1,OST=MBL;
<CONF CSC:CSC=1,OST=PLA;
<CONF CSC:CSC=2,OST=MBL;
<CONF CSC:CSC=2,OST=PLA;
<CONF CSC:CSC=3,OST=MBL;
<CONF CSC:CSC=3,OST=PLA;
/*
<STAT SSP;
/*
//***************************************************
//* COMMANDFILE FINISHED *
//***************************************************
//***************************************************
//* CHECK STATUS OF CSC-LINKS: *
//* ALL AVAILABLE CSC-LINKS IN PLA *
//***************************************************
//***************************************************
//* IF NECESSARY CONFIGURE CSC-LINKS MANUALLY *
//***************************************************
/*
<RESET CFOPT;
<ENDFILE;

P30305-X1118-G503-01-7618 12-69
12.6.13. Command File CF.17.PLAX25G503
<CMDFILE;
/* CF.17.PLAX25G503 */
/*
/***************************************************/
/* CF-NAME : CF.17.PLAX25G503 */
/* */
/* PURPOSE : CONFIGURATION OF X25-LINKS */
/* TO PLA */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* REMARKS : X25-LINK 0...7 */
/***************************************************/
/*
//***************************************************
//* COMMAND FILE CF.17.PLAX25G503 STARTED *
//***************************************************
//* CONFIGURATION OF X25-LINK 0..7 TO PLA *
//***************************************************
//***************************************************
//* IGNORE ERROR MESSAGES IF X25-LINK *
//* IS NOT AVAILABLE *
//***************************************************
/*
<SET CFOPT: ACKCFS=ALL,DANCMD=EXEC,ACKREQ=POS;
/*
<CONF X25LINK:X25LINK=0,OST=MBL;
<CONF X25LINK:X25LINK=0,OST=PLA;
<CONF X25LINK:X25LINK=1,OST=MBL;
<CONF X25LINK:X25LINK=1,OST=PLA;
<CONF X25LINK:X25LINK=2,OST=MBL;
<CONF X25LINK:X25LINK=2,OST=PLA;
<CONF X25LINK:X25LINK=3,OST=MBL;
<CONF X25LINK:X25LINK=3,OST=PLA;
<CONF X25LINK:X25LINK=4,OST=MBL;
<CONF X25LINK:X25LINK=4,OST=PLA;
<CONF X25LINK:X25LINK=5,OST=MBL;
<CONF X25LINK:X25LINK=5,OST=PLA;
<CONF X25LINK:X25LINK=6,OST=MBL;
<CONF X25LINK:X25LINK=6,OST=PLA;
<CONF X25LINK:X25LINK=7,OST=MBL;
<CONF X25LINK:X25LINK=7,OST=PLA;
/*
<STAT SSP;
/*
//***************************************************
//* CHECK STATUS OF X25-LINKS *
//* X25-LINK 0...7 MUST BE IN PLA *
//***************************************************
/*
<RESET CFOPT;
<ENDFILE;

12-70 P30305-X1118-G503-01-7618
12.6.14. Command File CF.17.PLAMBBG503
<CMDFILE;
/* CF.17.PLAMBBG503 */
/*
/***************************************************/
/* CF-NAME : CF.17.PLAMBBG503 */
/* */
/* PURPOSE : CONFIGURATION OF MB-UNITS TO PLA */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* REMARKS : MBUL 0...7, MBUS 0...3 */
/***************************************************/
/*
//***************************************************
//* COMMAND FILE CF.17.PLAMBBG503 STARTED *
//***************************************************
//* CONFIGURATION OF MB-UNITS TO PLA *
//***************************************************
//***************************************************
//* IGNORE ERROR MESSAGES IF MB-UNIT *
//* IS NOT AVAILABLE *
//***************************************************
/*
<SET CFOPT: ACKCFS=ALL, DANCMD=EXEC, ACKREQ=POS;
/*
<CONF MBUL: MB=0, MBUL=0, OST=PLA;
<CONF MBUL: MB=0, MBUL=1, OST=PLA;
<CONF MBUL: MB=0, MBUL=2, OST=PLA;
<CONF MBUL: MB=0, MBUL=3, OST=PLA;
<CONF MBUL: MB=0, MBUL=4, OST=PLA;
<CONF MBUL: MB=0, MBUL=5, OST=PLA;
<CONF MBUL: MB=0, MBUL=6, OST=PLA;
<CONF MBUL: MB=0, MBUL=7, OST=PLA;
/*
<CONF MBUS: MB=0, MBUS=0, OST=PLA;
<CONF MBUS: MB=0, MBUS=1, OST=PLA;
<CONF MBUS: MB=0, MBUS=2, OST=PLA;
<CONF MBUS: MB=0, MBUS=3, OST=PLA;
/*
<CONF MBUL: MB=1, MBUL=0, OST=PLA;
<CONF MBUL: MB=1, MBUL=1, OST=PLA;
<CONF MBUL: MB=1, MBUL=2, OST=PLA;
<CONF MBUL: MB=1, MBUL=3, OST=PLA;
<CONF MBUL: MB=1, MBUL=4, OST=PLA;
<CONF MBUL: MB=1, MBUL=5, OST=PLA;
<CONF MBUL: MB=1, MBUL=6, OST=PLA;
<CONF MBUL: MB=1, MBUL=7, OST=PLA;
/*
<CONF MBUS: MB=1, MBUS=0, OST=PLA;
<CONF MBUS: MB=1, MBUS=1, OST=PLA;
<CONF MBUS: MB=1, MBUS=2, OST=PLA;
<CONF MBUS: MB=1, MBUS=3, OST=PLA;
/*
//***************************************************
//* CHECK STATUS OF MBUL AND MBUS *
//* MBUL 0...7 AND MBUS 0...3 MUST BE IN PLA *
//***************************************************
/*
<RESET CFOPT;

P30305-X1118-G503-01-7618 12-71
<ENDFILE;

12-72 P30305-X1118-G503-01-7618
12.6.15. Command File CF.17.PROG503
<CMDFILE;
/* CF.17.PROG503 */
/*
/***************************************************/
/* CF-NAME : CF.17.PROG503 */
/* */
/* PURPOSE : START OF PROCESSES IN */
/* INSTALLATION RECOVERY V17 */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* REMARKS : */
/***************************************************/
/*
//***************************************************
//* COMMAND FILE CF.17.PROG503 STARTED *
//***************************************************
//* STARTING PROCESSES IN INSTALLATION RECOVERY V17 *
//***************************************************
/*
<SET CFOPT: ACKCFS=ALL, DANCMD=EXEC, ACKREQ=POS;
<START OM: APPL=Q3IF;
<START DB;
<START PROCESS: NAME=ICSRV;
/*
<START PROCESS: NAME=CLTLM;
/*
<START PROCESS: NAME=QACEN;
/*
<START PROCESS: NAME=GAILS;
/*
<START PROCESS: NAME=JIAUP;
/*
<START PROCESS: NAME=ASCEX;
/*
<START PROCESS: NAME=MMILF;
/*
<START PROCESS: NAME=MEINI;
/*
//***********************************************/
//* O K A Y */
//***********************************************/
/*
<RESET CFOPT;
<ENDFILE;

P30305-X1118-G503-01-7618 12-73
12.6.16. Command File CF.17.SYSTATG503
<CMDFILE;
/* CF.17.SYSTATG503 */
/*
/***************************************************/
/* CF-NAME : CF.17.SYSTATG503 */
/* */
/* PURPOSE : INQUIRY OF SYSTEM STATUS */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* REMARKS : */
/***************************************************/
/*
//***************************************************
//* COMMAND FILE CF.17.SYSTATG503 STARTED *
//***************************************************
//* INQUIRY OF SYSTEM STATUS *
//***************************************************
/*
<SET CFOPT: ACKCFS=ALL,DANCMD=EXEC,ACKREQ=POS;
/*
//********************************************
//* INQUIRY OF UPDATE STATUS *
//********************************************
<DISP SPLITOPT;
<DISP UPDATE;
<STAT LOG;
/*
//********************************************
//* INQUIRY OF DISK CONTENTS *
//********************************************
<DISP FILE;
<DISP MD;
<DISP GEN;
/*
/*
//********************************************
//* INQUIRY OF SYSTEM REDUNDANCY *
//********************************************
<STAT SSP;
<STAT MB;
<STAT SN;
<DISP SNDAT;
<STAT CCG;
<DISP CCG;
<STAT SYP;
<DISP LTG: LTG=X-X;
<STAT LTG: LTG=X-X;
<DISP DLU: DLU=X;
<STAT DLU: DLU=X;
<STAT DIU: LTG=X-X, OST=UNA;
<STAT CR: LTG=X-X, OST=UNA;
/*
/*

12-74 P30305-X1118-G503-01-7618
//********************************************
//* INQUIRY OF CCNC STATUS *
//********************************************
<STAT CCNC: UNIT=CCNP-X;
<STAT CCNC: UNIT=SIPA-X;
<STAT CCNC: UNIT=SILTC-X;
<STAT CCNC: UNIT=MUXM-X;
<STAT CCNC: UNIT=SILT-X;
/*
<DISP C7LINK: LSNAM=X;
<DISP C7LSET: LSNAM=X;
<DISP C7DP: DPC=X, NETIND=NAT0;
<DISP NUC;
/*
//********************************************
//* INQUIRY OF EXCHANGE DATA *
//********************************************
<DISP EXDDAT;
<STAT V5LINK: V5IFID=X, OST=ACT;
<DISP OUTSUP;
<DISP IAFEAT;
<DISP IAOPT;
<DISP METSAV;
<DISP SSPRT;
/*
//**********************************************
//* CHECK INTERROGATION RESULTS *
//**********************************************
//* IF NECESSARY CREATE REQUIRED CONFIGURATION *
//**********************************************
/*
<RESET CFOPT;
<ENDFILE;

P30305-X1118-G503-01-7618 12-75
12.6.17. Command File CF.17.UPDFILEG503
<CMDFILE;
/* CF.17.UPDFILEG503 */
/*
/***************************************************/
/* CF-NAME : CF.17.UPDFILEG503 */
/* */
/* LONG-NAME : UPDATING CHARGE FILES ON MDD */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* PURPOSE : UPDATING CHARGE FILES ON MDD: */
/* CA-,IA- AND IACHASTA */
/***************************************************/
/*
<SET CFOPT: ACKCFS=ALL,DANCMD=EXEC,ACKREQ=POS;
/*
//***************************************************
//* COMMANDFILE CF.17.UPDFILEG503 STARTED *
//***************************************************
//***************************************************
//* UPDATING CHARGE FILES ON MDD *
//***************************************************
/*
//************************************************
//* SAVING CA-CHARGING DATA *
//************************************************
/*
<DISP EXDDAT;
/*
<SAVE MET;
/*
//************************************************
//* SAVING IA-CHARGING DATA *
//************************************************
//* IGNORE ERROR MESSAGE FOR NOT AVAILABLE *
//* IA-TYPE *
//************************************************
/*
<DISP IAFEAT;
/*
<TRANS BUFFER:TYPE=AMA;
<TRANS BUFFER:TYPE=DNOB;
<TRANS BUFFER:TYPE=FIR;
<TRANS BUFFER:TYPE=IARA;
<TRANS BUFFER:TYPE=INA;
<TRANS BUFFER:TYPE=MAL;
<TRANS BUFFER:TYPE=MCR;
<TRANS BUFFER:TYPE=MOB;
<TRANS BUFFER:TYPE=PMOB;
<TRANS BUFFER:TYPE=TOB;
<TRANS BUFFER:TYPE=TST;
<TRANS BUFFER:TYPE=UAM;
/*
//************************************************
//* SAVING IACHASTA-CHARGING DATA *
//************************************************
//* IGNORE ERROR MESSAGE FOR NOT AVAILABLE *
//* IACHASTA-TYPE *
//************************************************

12-76 P30305-X1118-G503-01-7618
/*
//************************************************
//* SAVING IACHASTA-CHARGING DATA *

//************************************************
//* IGNORE ERROR MESSAGE FOR NOT AVAILABLE *
//* IACHASTA-TYPE *
//************************************************
/*
<DISP IACRG;
/*
<EDIT MET:TYPE=IACMET;
/*
//*************************************************
//* COMMANDFILE FINISHED *
//*************************************************
//*************************************************
//* CHECK IF ALL CREATED CHARGE FILES HAVE *
//* BEEN UPDATED ON MDD *
//*************************************************
//*************************************************
//* IF NECESSSARY UPDATE FILES MANUALLY *
//*************************************************
/*
<RESET CFOPT;
<ENDFILE;

P30305-X1118-G503-01-7618 12-77
12.7. Patch Files V11

12.7.1. Patch File PA.11.B2925L2Z


<CMDFILE;
/* PA.11.B2925L2Z */
/*
/*******************************************************/
/* CF-NAME : PA.11.B2925L2Z */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* PURPOSE : BLOCKING SUBSCRIBER CONTROLLED */
/* INPUTS V11 */
/*******************************************************/
/*
/* <SET CFOPT: DANCMD=EXEC, ACKREQ=POS, ACKCFS=ERROR, OFF=16;
// ************************************************************
// ** BLOCKING SUBSCRIBER CONTROLLED INPUTS V11 **
// ************************************************************
// ************************************************************
// ** **
// ** COMMANDFILE FOR PATCH APSLMY00.B2925L2Z.I2A1.0 STARTED **
// ** **
// ************************************************************
<ENTR CPPRPCH:
#ID="APSLMY00.B2925L2Z.I2A1.0",
#INSRADDR="BBSCPA0C.MMILCA0C_3605+H'19F4"&&"+H'06",
#SUBPPART=1-LAST,
#NEWCNT="2A7CFFFFFFFF4E40588F1D7C0002000B4EF9.A(BBSCPA0C.MMILCA0C
#_3605+H'19FE)",
#OLDCNT="2A7CFFFFFFFF";
<STEP;
<SKIP CMD: LABEL=ERROR0, ON=32;
/*
<ENTR CPPRPCH:
#ID="APSLMY00.B2925L2Z.I2A1.0",
#SUBPCHNO=1;
<STEP;
<SKIP CMD: LABEL=ERROR, ON=32;
/*
<UPD CPPRPCH: ID="APSLMY00.B2925L2Z.I2A1.0";
<STEP;
<SKIP CMD: LABEL=ERRORC, ON=32;
/*
<INCR APSVN;
<RESET CFOPT;
<ENDFILE;
/*
.ERROR0 <STEP;
// ***********************************************************
// ** **
// ** PATCH-ID APSLMY00.B2925L2Z.I2A1.0 ALREADY EXISTING OR **
// ** ERROR DURING FIRST ENTR-CPPRPCH (SEE DISPLAY OUTPUT) **
// ** **
// ***********************************************************
<SET CFOPT: ACKCFS=ALL;
<DISP CPPRPCH: ID="APSLMY00.B2925L2Z.I2A1.0";
<STEP;
<SET CFOPT: ACKCFS=ERROR, SCOPE=GLOBAL, ON=16;

12-78 P30305-X1118-G503-01-7618
<ENDFILE;

P30305-X1118-G503-01-7618 12-79
/*
.ERROR <STEP;
<SET CFOPT: ACKCFS=ALL;
<DISP CPPRPCH: ID="APSLMY00.B2925L2Z.I2A1.0";

<STEP;
<SET CFOPT: ACKCFS=ERROR;
/*
.ERRORC <STEP;
// **********************************************************
// ** **
// ** ERROR DURING ENTR-,ACT- OR UPD- CPPRPCH **
// ** PATCH-ID APSLMY00.B2925L2Z.I2A1.0 WILL BE REMOVED **
// ** **
// **********************************************************
<CAN CPPRPCH: ID="APSLMY00.B2925L2Z.I2A1.0";
<STEP;
<SKIP CMD: LABEL=ERRORA, ON=32;
/*
<SET CFOPT: SCOPE=GLOBAL, ON=16;
// **********************************************************
// ** **
// ** COMMANDFILE ABORTED **
// ** PATCH-ID APSLMY00.B2925L2Z.I2A1.0 **
// ** **
// **********************************************************
<ENDFILE;
.ERRORA <STEP;
// **********************************************************
// ** **
// ** ERROR DURING CANCEL CPPRPCH **
// ** PATCH-ID APSLMY00.B2925L2Z.I2A1.0 **
// ** **
// **********************************************************
<SET CFOPT: ACKCFS=ALL;
<DISP CPPRPCH: ID="APSLMY00.B2925L2Z.I2A1.0";
<STEP;
<SET CFOPT: ACKCFS=ERROR, SCOPE=GLOBAL, ON=16;
// **********************************************************
// ** **
// ** COMMANDFILE ABORTED **
// ** PATCH-ID APSLMY00.B2925L2Z.I2A1.0 **
// ** **
// **********************************************************
<ENDFILE;

12-80 P30305-X1118-G503-01-7618
12.7.2. Patch File PA.11.B2925L2J
<CMDFILE;
/* PA.11.B2925L2J */
/*
/*******************************************************/
/* CF-NAME : PA.11.B2925L2J */
/* */
/* COPYRIGHT (C) SIEMENS AG 2005 */
/* */
/* SSP-TYPE : CP113 */
/* */
/* AUTHOR : PSE SMC CI M */
/* */
/* PURPOSE : BACKOUT PATCH FOR PATCH B2925L2Z.I2A1*/
/*******************************************************/
/*
//************************************************************
//** COMMANDFILE FOR PATCH B2925L2J.I2A1 STARTED **
//************************************************************
/*
<SET CFOPT:DANCMD=EXEC,ACKREQ=POS,ACKCFS=ERROR,OFF=16;
<CAN CPPRPCH: ID="APSLMY00.B2925L2Z.I2A1.0";
<RESET CFOPT;
<ENDFILE;

P30305-X1118-G503-01-7618 12-81
12.8. Patch Files V17/CCNC
None

12-82 P30305-X1118-G503-01-7618
This page was left intentionally blank!

P30305-X1118-G503-01-7618 12-83
13. CHANGE REQUESTS TO THE SYSTEM UPGRADE PROCEDURE

From Name :

Project :

Date :

Code number : P30305-X1118-G503-01-7618

Title : SYSTEM UPGRADE


Combined Upgrade
V11/CP113D to V17/CCNC/CP113E

Author : L.Stefak, PSE SMC CI M

No. Page Line Suggested Change(s)

P30305-X1118-G503-01-7618 13-1
No. Page Line Suggested Change(s)

13-2 P30305-X1118-G503-01-7618