Вы находитесь на странице: 1из 1

Technical value May 2012 voda/sre

SW2-T-D10-T19/C9

Pull-out load FZ (N)

Part II (Subconstruction)
Material Embedment depth (mm) –x s


Wood
fir (C24) (350 kg/m3)
fir (C24) (350 kg/m3)
40
50
4183 154
5423 239

Pull-over load Fu (N) Part II

SW2-T-D10-T19/C9
Ø 5,5x30 Part I
Washer T19
Material Sheet thickness
Material
Part I in mm x s
Fastener:
Carbon steel 17B2 Kingspan 0,50 4101 212
Composite- 0,65 6083 286
Washer: panel 0,90 7987 426
Carbon steel 17B2 2 x 0,50 6070 253
2 x 0,65 8852 589
Size 2 x 0,90 13385 359
Head/Drive:
D10, T25 recess

Washer:
Ø 19 mm

Tensile breaking load Zb (N)

≥ = 15000

Shear breaking load Qb (N)

≥ = 8500

All stated values are x values, representing the arithmetical mean value from laboratory
x = arithmetical mean value testing concluded up to now, appropriate safety margins should be applied for field
s = Standard deviation conditions. Consult also your country’s approval documents.

Вам также может понравиться