Вы находитесь на странице: 1из 3

Beam Design

Beam Data
width 230 mm
depth 230 mm d' 54 mm .= cc+ sdia + mdia/2
clear cover to main 40 mm eff depth 176 mm .= d - d'
reinf.
Material Grades
Concrete 20 MPa
Steel 500 MPa

Moment 7.1 KN-m Mu/bd2 1.00


xumax 80 .= (700/(1100 * (0.87 * fy)) * d
Mulim 19 .= 0.36*fck*b*xumax*(d-(0.42*xumax))
Mulim/bd2 2.66

Beam is designed as Singly Reinforced Beam

Area of Steel Tension (Ast) Compr (Asc)


Percentage 0.244 % ------- Refer Table 2 SP 16 pg 48
Area of Steel 99 sqmm

Tension Reinforcement
Type Bar dia Nos Area of Steel
Layer 1 12 mm 2 226 sqmm
Layer 2 - 0
Layer 3 - 0
Total Steel Provided 226 sqmm 0.559 %
Provided Steel OK

Compression Reinforcement
Type Bar dia Nos Area of Steel
Layer 1 12 mm 2
Layer 2 -
Layer 3
Total Steel Provided #VALUE!

Shear Force (Vu) 25 KN


.=Vu / (b * d)
Refer Table 61 SP 16 pg 179 or =(0.85*√(0.8*fck)*√(1+5β)-1)) / (6β)
Refer Table J SP 16 pg 175
According to Clause 26.5.1.6 of IS 456-2000
Characteristic Strength (fy) of stirrup reinforcement
should not be greater than 415 Mpa.

16 mm 2
12 mm 4
-
#VALUE!

Type of stirrup 2 legged


8 mm
Column Design

Design Loads
Load Pu 113 KN
Moment Mu 18 KN-m

Column Data
width b 300 mm
depth d 300 mm
Eff.length le 4.06 meters ( C.l.E-3, Table-28, IS-456-2000)

Grade
Concrete fck 20 MPa
Steel fy 500 MPa

Pu/(fckbd) 0.06 Minimum eccentricity


Mu/(fckbd2) 0.01 ex 1.81 mm OK
d'/d 0.05 ey 1.81 mm OK

Refer Chart 35 of SP 16, Page no: 120

pt/fck 0.01

pt 0.20%
Ast 180 sqmm

Number of bars
dia nos ast
12 mm 4 452 sqmm ● ● 4- ###

- -

- - ● ●
Total 4 452 sqmm

Steel provided OK

Вам также может понравиться