Вы находитесь на странице: 1из 13

WI-IDEA-520XX/ Rev.

A
Gurgaon, India
=========================================================================

Work Instruction

Document Title : Flexi Packet Hub 800 Test Procedure

Document Number : WI-IDEA-520XX

Revision : A

Issue Date :

Revision Date : Initial release

Approved By Date
Signature Print name
(signed in original) Sanjay Sharma
Originator 29th July 2016

Signature Print name


(signed in original) Amar Singh
Operations 29th July 2016

Signature Print name


Engineering N/A N/A

Signature
(signed in original) Print name
Quality 29th July 2016
Pretty Gupta

=========================================================================
Page 1 of 13
THIS DOCUMENT IS THE SOLE PROPERTY OF COMMUNICATIONS TEST DESIGN INDIA PVT LTD., AND MAY NOT BE COPIED OR
REVEALED WITHOUT THEIR EXPRESSED WRITTEN CONSENT. POSSESSION ASSUMES AGREEMENT.
WI-IDEA-520XX/ Rev. A
Gurgaon, India
=========================================================================

1.0 Purpose:

This document describes the Testing Procedure for IDEA Flexi Packet Hub 800 IDU (Indoor
Unit).

2.0 Application:

This procedure applies to testing of Flexi Packet Hub 800 Unit in CTDI Gurgaon, India facility:-

3.0 Definitions:

Abbreviations: Description
UUT Unit under test
BER Bit Error Rate
CS Channel Spacing
CW Continuous Wave
IF Intermediate Frequency
LO Local Oscillator
LMP Local Management Port
RF Radio Frequency
RSL Receive Signal Level
Rx Receiver
SDH Synchronous Digital Hierarchy
QPSK Quadrature Phase Shift Keying
QAM Quadrature Amplitude Modulation
STM Synchronous Transfer Module
GSM Global System for Mobile Communications
TP Test Procedure
BTS Base Transceiver Station
Tx Transmitter
AGC Automatic Gain Control
Rev Revision

=========================================================================
Page 2 of 13
THIS DOCUMENT IS THE SOLE PROPERTY OF COMMUNICATIONS TEST DESIGN INDIA PVT LTD., AND MAY NOT BE COPIED OR
REVEALED WITHOUT THEIR EXPRESSED WRITTEN CONSENT. POSSESSION ASSUMES AGREEMENT.
WI-IDEA-520XX/ Rev. A
Gurgaon, India
=========================================================================

4.0 References:

STC Flexi Packet multi radio and IDU FPH800 configuration and commissioning

5.0 Procedure:

5.1 Basic Requirements for Testing.

Sr.No Description
1 PC with Operating System Windows 7 or XP Higher with
one com port, Java.
2 Power supply (-48V DC)
3 Reference ODU (Good)( High & Low frequencies each)
4 Reference IDU (Good)
5 RF Cable (RJ-45 to DIN connector),
6 SFP loopback
7 RJ-45 Cable(Straight),Power cable and Loopback
cable(E1/T1)

Physical Connections

 Connect Power cable into IDU.


 Connect ODUs (High & Low) with the IDU using RF cables.
 Connect 16xE1/T1 port with loopback cable.

Fig: 1

=========================================================================
Page 3 of 13
THIS DOCUMENT IS THE SOLE PROPERTY OF COMMUNICATIONS TEST DESIGN INDIA PVT LTD., AND MAY NOT BE COPIED OR
REVEALED WITHOUT THEIR EXPRESSED WRITTEN CONSENT. POSSESSION ASSUMES AGREEMENT.
WI-IDEA-520XX/ Rev. A
Gurgaon, India
=========================================================================

5.2 Flexi Packet Hub 800 configuration:


5.2.1 Open local area connection and set the IP as per fig.2

IP address - 192.168.254.130
Subnet Mask - 255.255.255.0

Fig: 2

5.2.2 Open a webpage on Google & enter IP. 192.168.254.100 in bookmark. Following
window will appear as per fig.3.

Fig: 3

=========================================================================
Page 4 of 13
THIS DOCUMENT IS THE SOLE PROPERTY OF COMMUNICATIONS TEST DESIGN INDIA PVT LTD., AND MAY NOT BE COPIED OR
REVEALED WITHOUT THEIR EXPRESSED WRITTEN CONSENT. POSSESSION ASSUMES AGREEMENT.
WI-IDEA-520XX/ Rev. A
Gurgaon, India
=========================================================================

5.2.3 Click on Login from Local IP as shown in fig.3 & following window will appear-

Fig: 4

5.2.4 Click on Run option in Security Warning Dialogue Box, then following Login window
will appear as per fig.5.
 Tick on – I accept the risk and want to run the application.

Fig: 5
=========================================================================
Page 5 of 13
THIS DOCUMENT IS THE SOLE PROPERTY OF COMMUNICATIONS TEST DESIGN INDIA PVT LTD., AND MAY NOT BE COPIED OR
REVEALED WITHOUT THEIR EXPRESSED WRITTEN CONSENT. POSSESSION ASSUMES AGREEMENT.
WI-IDEA-520XX/ Rev. A
Gurgaon, India
=========================================================================

5.2.5 Login using below login details as shown in fig. 6.


User Name - Admin
Password - sysmanager

Fig: 6
5.2.6 Following window will appear on Test PC display as per fig.7.

Fig: 7

=========================================================================
Page 6 of 13
THIS DOCUMENT IS THE SOLE PROPERTY OF COMMUNICATIONS TEST DESIGN INDIA PVT LTD., AND MAY NOT BE COPIED OR
REVEALED WITHOUT THEIR EXPRESSED WRITTEN CONSENT. POSSESSION ASSUMES AGREEMENT.
WI-IDEA-520XX/ Rev. A
Gurgaon, India
=========================================================================

5.2.7 Connect ODU to IDU with port 3. Click on highlighted ODU port 3 in fig. 8 &
following window will appear-

Fig: 8

5.2.8 Select ODU in Foreign equipment type- ODU, enable power supply & select admin
status as up (as perfig.9).Click on Apply.

Fig: 9
=========================================================================
Page 7 of 13
THIS DOCUMENT IS THE SOLE PROPERTY OF COMMUNICATIONS TEST DESIGN INDIA PVT LTD., AND MAY NOT BE COPIED OR
REVEALED WITHOUT THEIR EXPRESSED WRITTEN CONSENT. POSSESSION ASSUMES AGREEMENT.
WI-IDEA-520XX/ Rev. A
Gurgaon, India
=========================================================================

5.2.9 Port one Green Led blink in IDU and port active .Green led glow on Display (Test
PC) as per fig. 9.Down port 3.
5.2.10 Check Port 4 as per 5.2.7 to 5.2.9 steps.

5.2.11 Click on highlighted port1 as per fig.10. Connect line cable PC to Port 1.

Fig: 10

5.2.12 Properties → Admin Status → Up and click on Apply as per fig.11.

Fig: 11
=========================================================================
Page 8 of 13
THIS DOCUMENT IS THE SOLE PROPERTY OF COMMUNICATIONS TEST DESIGN INDIA PVT LTD., AND MAY NOT BE COPIED OR
REVEALED WITHOUT THEIR EXPRESSED WRITTEN CONSENT. POSSESSION ASSUMES AGREEMENT.
WI-IDEA-520XX/ Rev. A
Gurgaon, India
=========================================================================

5.2.13 One Green Led blinking in Port 1 and green led glow in display on port 1 as per
fig.12.

Fig: 12

5.2.14 Admin status → Down and click on apply. Check port 2 as per 5.2.11 to 5.2.13.

5.2.15 Click on highlighted SFP-1 as per fig.13. Connect SFP with port 1.

Fig: 13
=========================================================================
Page 9 of 13
THIS DOCUMENT IS THE SOLE PROPERTY OF COMMUNICATIONS TEST DESIGN INDIA PVT LTD., AND MAY NOT BE COPIED OR
REVEALED WITHOUT THEIR EXPRESSED WRITTEN CONSENT. POSSESSION ASSUMES AGREEMENT.
WI-IDEA-520XX/ Rev. A
Gurgaon, India
=========================================================================

5.2.16 STM-1 → Admin status → Up and click on Apply as per fig.14.

Fig: 14

5.2.17 Green Led glow on SFP-1 port in IDU and STM-1 → Admin status → Down, click on
apply.
5.2.18 Check SFP-2 as per 5.2.15 to 5.2.17.
5.2.19 Click on DCN port, check IP address as per fig.15.

Fig: 15
=========================================================================
Page 10 of 13
THIS DOCUMENT IS THE SOLE PROPERTY OF COMMUNICATIONS TEST DESIGN INDIA PVT LTD., AND MAY NOT BE COPIED OR
REVEALED WITHOUT THEIR EXPRESSED WRITTEN CONSENT. POSSESSION ASSUMES AGREEMENT.
WI-IDEA-520XX/ Rev. A
Gurgaon, India
=========================================================================

5.2.20 Test PC IP address as per DCN port Properties. Change test PC IP address as per
fig.16.
IP address - 10.255.96.208
Subnet Mask - 255.255.255.192

Fig: 16.

5.2.21 Open a webpage on Google & enter IP 10.255.96.207 in bookmark. Following


window will appear as per fig.17.

Fig: 17

=========================================================================
Page 11 of 13
THIS DOCUMENT IS THE SOLE PROPERTY OF COMMUNICATIONS TEST DESIGN INDIA PVT LTD., AND MAY NOT BE COPIED OR
REVEALED WITHOUT THEIR EXPRESSED WRITTEN CONSENT. POSSESSION ASSUMES AGREEMENT.
WI-IDEA-520XX/ Rev. A
Gurgaon, India
=========================================================================

5.2.22 Click on Login from Public IP as shown in fig.18 & following window will appear.

Fig: 18

5.2.23 Now follow 5.2.4 and 5.2.5 step. Login IDU.


5.2.24 Click on highlighted 16xE1/T1 as per fig.19.Connect Loopback cable(E1/T1).

Fig: 19

=========================================================================
Page 12 of 13
THIS DOCUMENT IS THE SOLE PROPERTY OF COMMUNICATIONS TEST DESIGN INDIA PVT LTD., AND MAY NOT BE COPIED OR
REVEALED WITHOUT THEIR EXPRESSED WRITTEN CONSENT. POSSESSION ASSUMES AGREEMENT.
WI-IDEA-520XX/ Rev. A
Gurgaon, India
=========================================================================

5.2.25 E1/T1 Port Properties → Admin Status → Up. Click On Apply as per fig.20
Two Major alarms show in Alarms box as per fig.21
 Far end sending AIS
 Near end sending AIS

Fig: 20

Fig: 21

=========================================================================
Page 13 of 13
THIS DOCUMENT IS THE SOLE PROPERTY OF COMMUNICATIONS TEST DESIGN INDIA PVT LTD., AND MAY NOT BE COPIED OR
REVEALED WITHOUT THEIR EXPRESSED WRITTEN CONSENT. POSSESSION ASSUMES AGREEMENT.

Вам также может понравиться